ABC Family Arquivos Brasileiros de Cardiologia International Journal of Cardiovascular Sciences ABC Heart Failure & Cardiomyopathy ABC Imagem Cardiovascular
Português English
ABC Family
Português English
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News

ABC Family

  • ABC Family
  • Arquivos Brasileiros de Cardiologia
  • International Journal of Cardiovascular Sciences
  • ABC Heart Failure & Cardiomyopathy
  • ABC Imagem Cardiovascular
Search in

No content found.

Journals
Ordering
Article types
Others

  1. Home
  2. Keyword: Electrodes, Implanted
Figura 1
ABC
Original Article

Effectiveness and Safety of Transvenous Removal of Cardiac Pacing and Implantable Cardioverter-defibrillator Leads in the Real Clinical Scenario

Roberto Costa et al. Katia Regina da Silva Elizabeth Sartori Crevelari Wagner Tadeu Jurevicius Nascimento … Marcia Mitie Nagumo Martino Martinelli Filho Fabio Biscegli Jatene

Abstract

Background

Transvenous lead extraction (TLE) of cardiac implantable electronic devices (CIED) is an uncommon procedure and requires specialized personnel and adequate facilities.

Objectives

To evaluate the effectiveness and safety of the removal of CIED leads and to determine risk factors for surgical complications and mortality in 30 days.

Methods

Prospective study with data derived from clinical practice. From January 2014 to April 2020, we included 365 consecutive patients who underwent TLE, regardless of the indication and surgical technique used. The primary outcomes were: success rate of the procedure, combined rate of major complications and intraoperative death. Secondary outcomes were: risk factors for major intraoperative complications and death within 30 days. Univariate and multivariate analysis were used, with a significance level of 5%.

Results

Procedure success rate was 96.7%, with 90.1% of complete success and 6.6% of clinical success. Major intraoperative complications occurred in 15 (4.1%) patients. Predictors of major complications were: lead dwelling time ≥ 7 years (OR = 3.78, p = 0.046) and change in surgical strategy (OR = 5.30, p = 0.023). Functional class III-IV (OR = 6.98, p <0.001), renal failure (OR = 5.75, p = 0.001), CIED infection (OR = 13.30, p <0.001), number of procedures performed (OR = 77.32, p <0.001) and major intraoperative complications (OR = 38.84, p <0.001) were predictors of 30-day mortality.

Conclusions

The results of this study, which is the largest prospective registry of consecutive TLE procedures in Latin America, confirm the safety and effectiveness of this procedure in the context of real clinical practice. (Arq Bras Cardiol. 2020; 115(6):1114-1124)

  • Cardiac Pacing, Artificial
  • Effectiveness
  • Electrodes, Implanted
  • Infection
  • Mortality
  • Pacemaker
  • Surgical complications
  • Transvenous lead extracion
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
18/01/2021 DOI: 10.36660/abc.20200476 Views 1
ABC
Editorial

Reintervention in Artificial Cardiac Pacing Systems

Silas dos Santos Galvão Filho

Reintervention in artificial cardiac pacing systems that involves lead approach, either for the implantation of a new lead and/or the removal of an old one, is most frequently a difficult procedure, with a high probability of complications. Since the transvenous endocardial route started being used by artificial cardiac pacing systems, lead cables have shown to be more vulnerable to complications; however, when it comes to reintervention, the complications are much more frequent.

The significant prevalence of venous obstruction and the consequent difficulty in obtaining a new venous access, the complexity of percutaneous extraction of old lead cables, in addition to the higher prevalence of surgical infections, constitute some of the complications that determine the greater complexity of reinterventions.

[…]

  • Arrhythmias Cardiac
  • Catheter Ablation
  • Electrodes, Implanted
  • Intraoperative Complications
  • Pacemaker, Artificial/trends
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
01/11/2018 DOI: 10.5935/abc.20180222
Azygos vein lead implantation: a therapeutic option for elevated defibrillation threshold
ABC
Case Report

Azygos vein lead implantation: a therapeutic option for elevated defibrillation threshold

Luiz Eduardo Montenegro Camanho et al. Antonio Carlos Botelho da Silva Marco Antonio Teixeira Luiz Antonio Inácio Oliveira Junior … Eduardo Benchimol Saad Marcelo da Costa Maia

The evaluation of the defibrillation threshold (DFT) during the implantation of a cardioverter-defibrillator (ICD) is an important stage of the procedure, as a high DFT can be found in up to 16% of patients. We report a patient with idiopathic dilated cardiomyopathy (DCM) submitted to a biventricular ICD implantation. During the procedure, the patient showed a high DFT and showed to be resistant to usual therapeutic modalities. We opted for the azygos vein defibrillation lead implantation, with good resolution.

  • azygos vein
  • Cardiomyopathy, Dilated
  • Defibrillators, Implantable
  • Electrodes, Implanted
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
08/08/2012 DOI: 10.1590/S0066-782X2012000600017 Views 1
Pacemaker electrode misplaced in the left ventricle
ABC
Case Report

Pacemaker electrode misplaced in the left ventricle

André Luiz Cerqueira de Almeida et al. Viviane Machicado Cavalcante Márcio Diego Castro Teixeira Gustavo Rocha Costa de Freitas

This study reports the case of an anomalous implantation of VVI pacemaker electrode in the left ventricle (LV) diagnosed during routine evaluation, two years after implantation. The patient is a 65-year-old woman with Chagas disease. Electrocardiogram (ECG) revealed a pattern of right branch block. Profile chest X-ray showed electrode with posterior curvature path. In transthoracic echocardiography, the diagnosis revealed that the catheter penetrated the right atrium, crossed the atrial septum, descended through the left atrium and mitral valve orifice and deployed on the LV wall. The following related aspects are addressed: potential deployment routes, clinical, radiological, electrocardiographic and echocardiographic pictures, complications and treatment options.

  • Atrioventricular block
  • Electrodes, Implanted
  • left ventricle
  • Pacemaker, Artificial
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
13/10/2010 DOI: 10.1590/S0066-782X2010001300022 Views 1
Ectopic positioning of pacemaker electrode
ABC
Case Report

Ectopic positioning of pacemaker electrode

Gildo Mota et al. Juliana Prazeres Nelmacy Freitas Luiz Magalhães … Francisco Reis Roque Aras

The present case reports on a patient presenting the cardiac form of Chagas disease, with left ventricular dysfunction and second-degree atrioventricular block Mobitz type II, associated with several syncope episodes. The patient underwent a double-chamber definitive artificial pacemaker implant. One year after the implant, the displacement of the atrial electrode was diagnosed and the patient was submitted to re-implantation of the atrial electrode. Two years after the first surgical procedure, the patient presented dyspnea on exertion. The physical evaluation included an echocardiogram, which detected the presence of a foreign body with metallic characteristics in the left cardiac chambers, consistent with that of an ectopic pacemaker electrode.

  • Chagas disease
  • Electrodes, Implanted
  • Pacemaker, Artificial
  • Ventricular Dysfunction, Left
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
22/09/2010 DOI: 10.1590/S0066-782X2010000500023 Views 1

How to cite this article

EndNote RIS

Electronic Document Format (Vancouver)

Costa R, Silva KR, Crevelari ES, Nascimento WTJ, Nagumo MM, Martinelli Filho M, Jatene FB, et al. Effectiveness and Safety of Transvenous Removal of Cardiac Pacing and Implantable Cardioverter-defibrillator Leads in the Real Clinical Scenario. Arquivos Brasileiros de Cardiologia 2021;115(6):1114-2.

Electronic Document Format (ABNT)

Costa, Roberto; Silva, Katia Regina da; Crevelari, Elizabeth Sartori; Nascimento, Wagner Tadeu Jurevicius; Nagumo, Marcia Mitie; Martinelli Filho, Martino; Jatene, Fabio Biscegli. Effectiveness and Safety of Transvenous Removal of Cardiac Pacing and Implantable Cardioverter-defibrillator Leads in the Real Clinical Scenario. Arquivos Brasileiros de Cardiologia, v. 115, n. 6, p. 1114-1124, Jan. 2021.

Electronic Document Format (APA)

Costa, R., Silva, K. R. , Crevelari, E. S., Nascimento, W. T. J., Nagumo, M. M., Martinelli Filho, M., & Jatene, F. B. (2021). Effectiveness and Safety of Transvenous Removal of Cardiac Pacing and Implantable Cardioverter-defibrillator Leads in the Real Clinical Scenario. Arquivos Brasileiros de Cardiologia, 115(6), 1114-1124.

Electronic Document Format (ISO)

Costa, Roberto and Silva, Katia Regina da and Crevelari, Elizabeth Sartori and Nascimento, Wagner Tadeu Jurevicius and Nagumo, Marcia Mitie and Martinelli Filho, Martino and Jatene, Fabio Biscegli. Effectiveness and Safety of Transvenous Removal of Cardiac Pacing and Implantable Cardioverter-defibrillator Leads in the Real Clinical Scenario. Arquivos Brasileiros de Cardiologia [online]. 2021, vol. 115, n. 6, [cited 2026-10-14], pp. 1114-1124. Available from: <https://journals.cardiol.br/en/article/effectiveness-and-safety-of-transvenous-removal-of-cardiac-pacing-and-implantable-cardioverter-defibrillator-leads-in-the-real-clinical-scenario/>. ISSN 0066-782X

EndNote RIS

Electronic Document Format (Vancouver)

Galvão Filho SS. Reintervention in Artificial Cardiac Pacing Systems. Arquivos Brasileiros de Cardiologia 2018;111(5):697-8.

Electronic Document Format (ABNT)

Galvão Filho, Silas dos Santos. Reintervention in Artificial Cardiac Pacing Systems. Arquivos Brasileiros de Cardiologia, v. 111, n. 5, p. 697-698, Oct. 2018.

Electronic Document Format (APA)

Galvão Filho, S. S. (2018). Reintervention in Artificial Cardiac Pacing Systems. Arquivos Brasileiros de Cardiologia, 111(5), 697-698.

Electronic Document Format (ISO)

Galvão Filho, Silas dos Santos. Reintervention in Artificial Cardiac Pacing Systems. Arquivos Brasileiros de Cardiologia [online]. 2018, vol. 111, n. 5, [cited 2026-10-14], pp. 697-698. Available from: <https://journals.cardiol.br/en/article/reintervention-in-artificial-cardiac-pacing-systems/>. ISSN 0066-782X

EndNote RIS

Electronic Document Format (Vancouver)

Camanho LEM, Silva ACB, Teixeira MA, Oliveira Junior LAI, Saad EB, Maia MC. Azygos vein lead implantation: a therapeutic option for elevated defibrillation threshold. Arquivos Brasileiros de Cardiologia 2012;98(6):e98-e101.

Electronic Document Format (ABNT)

Camanho, Luiz Eduardo Montenegro; Silva, Antonio Carlos Botelho da; Teixeira, Marco Antonio; Oliveira Junior, Luiz Antonio Inácio; Saad, Eduardo Benchimol; Maia, Marcelo da Costa. Azygos vein lead implantation: a therapeutic option for elevated defibrillation threshold. Arquivos Brasileiros de Cardiologia, v. 98, n. 6, p. e98-e101, Aug. 2012.

Electronic Document Format (APA)

Camanho, L. E. M., Silva, A. C. B. , Teixeira, M. A., Oliveira Junior, L. A. I., Saad, E. B., & Maia, M. C. (2012). Azygos vein lead implantation: a therapeutic option for elevated defibrillation threshold. Arquivos Brasileiros de Cardiologia, 98(6), e98-e101.

Electronic Document Format (ISO)

Camanho, Luiz Eduardo Montenegro and Silva, Antonio Carlos Botelho da and Teixeira, Marco Antonio and Oliveira Junior, Luiz Antonio Inácio and Saad, Eduardo Benchimol and Maia, Marcelo da Costa. Azygos vein lead implantation: a therapeutic option for elevated defibrillation threshold. Arquivos Brasileiros de Cardiologia [online]. 2012, vol. 98, n. 6, [cited 2026-10-14], pp. e98-e101. Available from: <https://journals.cardiol.br/en/article/azygos-vein-lead-implantation-a-therapeutic-option-for-elevated-defibrillation-threshold/>. ISSN 0066-782X

EndNote RIS

Electronic Document Format (Vancouver)

Almeida ALC, Cavalcante VM, Teixeira MDC, Freitas GRC. Pacemaker electrode misplaced in the left ventricle. Arquivos Brasileiros de Cardiologia 2010;95(3):e83-7.

Electronic Document Format (ABNT)

Almeida, André Luiz Cerqueira de; Cavalcante, Viviane Machicado; Teixeira, Márcio Diego Castro; Freitas, Gustavo Rocha Costa de. Pacemaker electrode misplaced in the left ventricle. Arquivos Brasileiros de Cardiologia, v. 95, n. 3, p. e83-e87, Oct. 2010.

Electronic Document Format (APA)

Almeida, A. L. C. , Cavalcante, V. M., Teixeira, M. D. C., & Freitas, G. R. C. (2010). Pacemaker electrode misplaced in the left ventricle. Arquivos Brasileiros de Cardiologia, 95(3), e83-e87.

Electronic Document Format (ISO)

Almeida, André Luiz Cerqueira de and Cavalcante, Viviane Machicado and Teixeira, Márcio Diego Castro and Freitas, Gustavo Rocha Costa de. Pacemaker electrode misplaced in the left ventricle. Arquivos Brasileiros de Cardiologia [online]. 2010, vol. 95, n. 3, [cited 2026-10-14], pp. e83-e87. Available from: <https://journals.cardiol.br/en/article/pacemaker-electrode-misplaced-in-the-left-ventricle/>. ISSN 0066-782X

EndNote RIS

Electronic Document Format (Vancouver)

Mota G, Prazeres J, Freitas N, Magalhães L, Reis F, Aras R. Ectopic positioning of pacemaker electrode. Arquivos Brasileiros de Cardiologia 2010;94(5):e122-4.

Electronic Document Format (ABNT)

Mota, Gildo; Prazeres, Juliana; Freitas, Nelmacy; Magalhães, Luiz; Reis, Francisco; Aras, Roque. Ectopic positioning of pacemaker electrode. Arquivos Brasileiros de Cardiologia, v. 94, n. 5, p. e122-e124, Sep. 2010.

Electronic Document Format (APA)

Mota, G., Prazeres, J., Freitas, N., Magalhães, L., Reis, F., & Aras, R. (2010). Ectopic positioning of pacemaker electrode. Arquivos Brasileiros de Cardiologia, 94(5), e122-e124.

Electronic Document Format (ISO)

Mota, Gildo and Prazeres, Juliana and Freitas, Nelmacy and Magalhães, Luiz and Reis, Francisco and Aras, Roque. Ectopic positioning of pacemaker electrode. Arquivos Brasileiros de Cardiologia [online]. 2010, vol. 94, n. 5, [cited 2026-10-14], pp. e122-e124. Available from: <https://journals.cardiol.br/en/article/ectopic-positioning-of-pacemaker-electrode/>. ISSN 0066-782X

  • About ABC Family
  • Internal Regulation
  • Editorial Board
  • Brazilian Society of Cardiology (SBC)

Issues

SBC Guidelines

  • Videos
  • Podcasts
  • News