ABC Family Arquivos Brasileiros de Cardiologia International Journal of Cardiovascular Sciences ABC Heart Failure & Cardiomyopathy ABC Imagem Cardiovascular
Português English
ABC Family
Português English
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News

ABC Family

  • ABC Family
  • Arquivos Brasileiros de Cardiologia
  • International Journal of Cardiovascular Sciences
  • ABC Heart Failure & Cardiomyopathy
  • ABC Imagem Cardiovascular
Search in

No content found.

Journals
Ordering
Article types
Others

  1. Home
  2. Keyword: Equipment Failure
IJCS
Original Article

Evaluation of the Profile and Quality of Sphygmomanometers Available at a Health Education Institution in Belo Horizonte

Matheus Evangelista da Costa et al. Sarah Mattos Moraes Kleisson Antonio Pontes Maia

Abstract

Background

Arterial hypertension affects around 30% of the Brazilian adult population, showing a direct and progressive relationship with an increased risk of cardiovascular diseases (CVDs). In this context, adjustments in the calibration and physical constitution of sphygmomanometers are essential conditions for obtaining correct blood pressure (BP) measurements.

Objectives

Analyze the profile and quality of sphygmomanometers used in various sectors of a health education institution in Belo Horizonte, Minas Gerais.

Methods

The present study conducted a cross-sectional, observational, and non-interventional study to assess adherence to various quality parameters of the sphygmomanometers available in the outpatient clinic, emergency department, and ward of an educational institution in the municipality of Belo Horizonte.

Results

We analyzed 78 devices, in which high rates of adherence were identified for velcro/pins, 93.5% (73/78); bulbs/rubbers, 92.1% (70/76); valves, 93.4% (71/76); the seal of the National Institute of Metrology, Quality, and Technology (INMETRO), 97.4% (76/78); and the clock, 92.1% (70/76). However, these parameters showed no statistical significance. Institutions (hospital/outpatient clinic) recorded higher calibration rates, 75% (39/52, p<0.001), in accordance with the deadlines stipulated by INMETRO, and the cuff/equipment compatibility showed its highest value (52%) among students (32/61, p = 0.004).

Conclusion

Our study showed that 38.4% (30/78) of the devices did not presented some type of inadequacy, with outpatient-owned devices had the highest compliance rate (p = 0.015). These findings are worrisome, as they can lead to inaccurate BP measurements.

  • Cardiovascular Diseases
  • Equipment Failure
  • Hypertension
  • Sphygmomanometers
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
11/03/2024 DOI: 10.36660/ijcs.20230175 Views 2
IJCS
Original Article

Inadequacies of Sphygmomanometers Used in Emergency Care Services in a Large Capital City in Brazil

Kleisson Antonio Pontes Maia et al. Marcus Vinícius Bolívar Malachias Isabela Viana de Paiva Rafael da Mota Mariano Rodrigo Viana de Paiva

Abstract

Background:

Hypertension is the main risk factor for cardiovascular diseases. Technical quality of sphygmomanometers is a prerequisite for the correct measurement of arterial pressure.

Objectives:

To evaluate sphygmomanometers available in emergency services in the city of Belo Horizonte, Brazil.

Methods:

We performed a cross-sectional, observational, non-interventional study to evaluate characteristics of the sphygmomanometers available in adult emergency services of public and private hospitals in the city of Belo Horizonte, Brazil. We evaluated 337 sphygmomanometers of 25 hospitals – 15 (of 16) public hospitals and 10 (of 12) private hospitals.

Results:

Twenty-six percent (88/337) of devices were considered inadequate regarding the INMETRO (National Institute of Metrology, Quality and Technology) standards, 39.2% (132/337) for calibration dates, and 54% (188/337) for the mismatching between cuff’s and device’s brands. In 13 of 25 hospitals (52%), there were no spare cuffs in different sizes for different arm circumferences. Higher adequacy was found for aneroid and mercury sphygmomanometers used in private hospitals (p = 0.038 and p < 0.001, respectively) and electronic devices used in public hospitals (p < 0.001) compared with others.

Conclusion:

Seventy-eight percent of sphygmomanometers available in emergency services had technical inadequacies, and half of these services had no spare cuffs in different sizes available. These findings serve as a warning of the conditions of the equipment used in healthcare services provided to the general population in Brazil.

  • Emergency Medical Services
  • Equipment Failure
  • Hospitals, Private
  • Hospitals, Public
  • Hypertension
  • Sphygmomanometers
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
01/01/2017 DOI: 10.5935/2359-4802.20170028 Views 1

How to cite this article

EndNote RIS

Electronic Document Format (Vancouver)

Costa ME, Moraes SM, Maia KAP. Evaluation of the Profile and Quality of Sphygmomanometers Available at a Health Education Institution in Belo Horizonte. International Journal of Cardiovascular Sciences 2024;37:e20230175.

Electronic Document Format (ABNT)

Costa, Matheus Evangelista da; Moraes, Sarah Mattos; Maia, Kleisson Antonio Pontes. Evaluation of the Profile and Quality of Sphygmomanometers Available at a Health Education Institution in Belo Horizonte. International Journal of Cardiovascular Sciences, v. 37, e20230175, Mar. 2024.

Electronic Document Format (APA)

Costa, M. E. , Moraes, S. M., & Maia, K. A. P. (2024). Evaluation of the Profile and Quality of Sphygmomanometers Available at a Health Education Institution in Belo Horizonte. International Journal of Cardiovascular Sciences, 37, e20230175.

Electronic Document Format (ISO)

Costa, Matheus Evangelista da and Moraes, Sarah Mattos and Maia, Kleisson Antonio Pontes. Evaluation of the Profile and Quality of Sphygmomanometers Available at a Health Education Institution in Belo Horizonte. International Journal of Cardiovascular Sciences [online]. 2024, vol. 37, [cited 2026-10-14], e20230175. Available from: <https://journals.cardiol.br/en/article/evaluation-of-the-profile-and-quality-of-sphygmomanometers-available-at-a-health-education-institution-in-belo-horizonte/>. ISSN 2359-4802

EndNote RIS

Electronic Document Format (Vancouver)

Maia KAP, Malachias MVB, Paiva IV, Mariano RM, Paiva RV. Inadequacies of Sphygmomanometers Used in Emergency Care Services in a Large Capital City in Brazil. International Journal of Cardiovascular Sciences 2017;30(2):100-8.

Electronic Document Format (ABNT)

Maia, Kleisson Antonio Pontes; Malachias, Marcus Vinícius Bolívar; Paiva, Isabela Viana de; Mariano, Rafael da Mota; Paiva, Rodrigo Viana de. Inadequacies of Sphygmomanometers Used in Emergency Care Services in a Large Capital City in Brazil. International Journal of Cardiovascular Sciences, v. 30, n. 2, p. 100-108, Dec. 2016.

Electronic Document Format (APA)

Maia, K. A. P., Malachias, M. V. B., Paiva, I. V. , Mariano, R. M., & Paiva, R. V. (2017). Inadequacies of Sphygmomanometers Used in Emergency Care Services in a Large Capital City in Brazil. International Journal of Cardiovascular Sciences, 30(2), 100-108.

Electronic Document Format (ISO)

Maia, Kleisson Antonio Pontes and Malachias, Marcus Vinícius Bolívar and Paiva, Isabela Viana de and Mariano, Rafael da Mota and Paiva, Rodrigo Viana de. Inadequacies of Sphygmomanometers Used in Emergency Care Services in a Large Capital City in Brazil. International Journal of Cardiovascular Sciences [online]. 2017, vol. 30, n. 2, [cited 2026-10-14], pp. 100-108. Available from: <https://journals.cardiol.br/en/article/inadequacies-of-sphygmomanometers-used-in-emergency-care-services-in-a-large-capital-city-in-brazil/>. ISSN 2359-4802

  • About ABC Family
  • Internal Regulation
  • Editorial Board
  • Brazilian Society of Cardiology (SBC)

Issues

SBC Guidelines

  • Videos
  • Podcasts
  • News