ABC Family Arquivos Brasileiros de Cardiologia International Journal of Cardiovascular Sciences ABC Heart Failure & Cardiomyopathy ABC Imagem Cardiovascular
Português English
ABC Family
Português English
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News

ABC Family

  • ABC Family
  • Arquivos Brasileiros de Cardiologia
  • International Journal of Cardiovascular Sciences
  • ABC Heart Failure & Cardiomyopathy
  • ABC Imagem Cardiovascular
Search in

No content found.

Journals
Ordering
Article types
Others

  1. Home
  2. Keyword: valve replacement
Surgical treatment of aortic valve disease with stentless bovine pericardium prosthesis: immediate results
ABC
Artigo Original

Surgical treatment of aortic valve disease with stentless bovine pericardium prosthesis: immediate results

Wesley Ferreira de Araújo et al. Luis Roberto Gerola Hyoung C. Kin Armindo Pereira Filho … Guilherme Flora Vargas Roberto Catani Enio Buffolo

OBJECTIVE: To present the immediate results and assess the clinical and hemodynamic performance of stentless bovine pericardial bioprostheses in aortic position. METHODS: Twenty patients were operated who were indicated for surgery for valve replacement with biological prostesis. Eleven patients were male; sixteen had aortic stenosis; four, insufficiency; the mean age was 66.3 ± 8.8 years. The surgical technique used was subcoronary implant. Associated procedures were performed in five patients. Postoperative morbidity,mortality and hemodynamic performance were assessed on transthoracic echocardiogram. RESULTS: Mean time of cardiopulmonary bypass was 136.5 ± 24.41 minutes and mean anoxic time was 105.2 ± 21.62 minutes. Hospital mortality was 5% (one patient). Mean time of intensive care unit stay was 3.65 ± 3.23 days. Mean postoperatively transvalvular gradient was was 25.39 ± 7.82 mmHg. Left ventricle ejection fraction was 67 ± 13.49% preoperatively and 63.24 ± 16.06% postoperatively (p = 0.45). Eleven patients did not present any degree of valve regurgitation, eight presented mild regurgitation and one ,mild to moderate regurgitation. CONCLUSION: Stentless prostheses can be used for the surgical tratment of aortic valve diseases, with in hospital mortality and morbidity similar to the mortality and morbidity described in the literature for similar procedures, with satisfactory hemodynamic performance.

  • Aortic Valve
  • Bioprosthesis
  • stentless bioprosthesis
  • stentless prosthesis
  • valve replacement
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
28/07/2006 DOI: 10.1590/S0066-782X2006001400004 Views 2
ABC
Artigo Original

Cryopreserved aortic homograft for aortic valve replacement: immediate results

Luís Roberto Gerola et al. Wesley Araújo Hyong C. Kin Gabriela E. F. Silva … Armindo Pereira Filho Guilherme Flora Vargas Enio Buffolo

OBJECTIVE: To assess immediate clinical and echocardiographic results of the use of cryopreserved aortic homografts for aortic valve replacement. METHODS: Eighteen patients with aortic valve disease underwent aortic valve replacement, receiving a cryopreserved aortic homograft, 15 were male, 10 had aortic regurgitation, and 8 had aortic stenosis. Age ranged from 18 to 65 years (mean, 44.5 ± 18.14 years). Four patients had infective endocarditis, 12 patients were in functional class II, and 6 patients were in functional class III (NYHA). Left ventricular function was normal in 15 patients. RESULTS: Hospital mortality was 5.5% (1 patient) due to respiratory distress; the other patients were discharged from the hospital between the fifth and eighth postoperative days in functional class I. Maximal aortic transvalvular gradient, on echocardiography, ranged from 0 to 30 mmHg, with a mean of 10.9 ± 9.2 mmHg. Five patients did not have any degree of regurgitation through the aortic homograft, 11 patients (61.1%) had minimal regurgitation, and 2 had mild regurgitation. Duration of extracorporeal circulation ranged from 130 to 220 minutes (mean, 183.9 ± 36.7 minutes). Duration of aortic clamping ranged from 102 to 168 minutes (mean, 139.14 ± 25.10 minutes). Bleeding in the postoperative period ranged from 210 to 1220 mL, with a mean of 511.4 ± 335.1 mL. Reoperations were not necessary. Duration of orotracheal intubation ranged from 2 hours 50 minutes to 17 hours with a mean of 9.14 ± 3.6 hours. CONCLUSION: Cryopreserved aortic homografts may be routinely used with low hospital morbidity and mortality.

  • aortic homograft
  • Aortic Valve Disease
  • valve replacement
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
22/10/2004 DOI: 10.1590/S0066-782X2004001600003 Views 1

How to cite this article

EndNote RIS

Electronic Document Format (Vancouver)

Araújo WF, Gerola LR, Kin HC, Pereira Filho A, Vargas GF, Catani R, Buffolo E, et al. Surgical treatment of aortic valve disease with stentless bovine pericardium prosthesis: immediate results. Arquivos Brasileiros de Cardiologia 2006;87(1):22-7.

Electronic Document Format (ABNT)

Araújo, Wesley Ferreira de; Gerola, Luis Roberto; Kin, Hyoung C.; Pereira Filho, Armindo; Vargas, Guilherme Flora; Catani, Roberto; Buffolo, Enio. Surgical treatment of aortic valve disease with stentless bovine pericardium prosthesis: immediate results. Arquivos Brasileiros de Cardiologia, v. 87, n. 1, p. 22-27, Jul. 2006.

Electronic Document Format (APA)

Araújo, W. F. , Gerola, L. R., Kin, H. C., Pereira Filho, A., Vargas, G. F., Catani, R., & Buffolo, E. (2006). Surgical treatment of aortic valve disease with stentless bovine pericardium prosthesis: immediate results. Arquivos Brasileiros de Cardiologia, 87(1), 22-27.

Electronic Document Format (ISO)

Araújo, Wesley Ferreira de and Gerola, Luis Roberto and Kin, Hyoung C. and Pereira Filho, Armindo and Vargas, Guilherme Flora and Catani, Roberto and Buffolo, Enio. Surgical treatment of aortic valve disease with stentless bovine pericardium prosthesis: immediate results. Arquivos Brasileiros de Cardiologia [online]. 2006, vol. 87, n. 1, [cited 2026-10-14], pp. 22-27. Available from: <https://journals.cardiol.br/en/article/surgical-treatment-of-aortic-valve-disease-with-stentless-bovine-pericardium-prosthesis-immediate-results/>. ISSN 0066-782X

EndNote RIS

Electronic Document Format (Vancouver)

Gerola LR, Araújo W, Kin HC, Silva GEF, Pereira Filho A, Vargas GF, Buffolo E, et al. Cryopreserved aortic homograft for aortic valve replacement: immediate results. Arquivos Brasileiros de Cardiologia 2004;83(4):280-3.

Electronic Document Format (ABNT)

Gerola, Luís Roberto; Araújo, Wesley; Kin, Hyong C.; Silva, Gabriela E. F.; Pereira Filho, Armindo; Vargas, Guilherme Flora; Buffolo, Enio. Cryopreserved aortic homograft for aortic valve replacement: immediate results. Arquivos Brasileiros de Cardiologia, v. 83, n. 4, p. 280-283, Oct. 2004.

Electronic Document Format (APA)

Gerola, L. R., Araújo, W., Kin, H. C., Silva, G. E. F., Pereira Filho, A., Vargas, G. F., & Buffolo, E. (2004). Cryopreserved aortic homograft for aortic valve replacement: immediate results. Arquivos Brasileiros de Cardiologia, 83(4), 280-283.

Electronic Document Format (ISO)

Gerola, Luís Roberto and Araújo, Wesley and Kin, Hyong C. and Silva, Gabriela E. F. and Pereira Filho, Armindo and Vargas, Guilherme Flora and Buffolo, Enio. Cryopreserved aortic homograft for aortic valve replacement: immediate results. Arquivos Brasileiros de Cardiologia [online]. 2004, vol. 83, n. 4, [cited 2026-10-14], pp. 280-283. Available from: <https://journals.cardiol.br/en/article/cryopreserved-aortic-homograft-for-aortic-valve-replacement-immediate-results/>. ISSN 0066-782X

  • About ABC Family
  • Internal Regulation
  • Editorial Board
  • Brazilian Society of Cardiology (SBC)

Issues

SBC Guidelines

  • Videos
  • Podcasts
  • News