ABC Family Arquivos Brasileiros de Cardiologia International Journal of Cardiovascular Sciences ABC Heart Failure & Cardiomyopathy ABC Imagem Cardiovascular
Português English
ABC Family
Português English
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News

ABC Family

  • ABC Family
  • Arquivos Brasileiros de Cardiologia
  • International Journal of Cardiovascular Sciences
  • ABC Heart Failure & Cardiomyopathy
  • ABC Imagem Cardiovascular
Search in

No content found.

Journals
Ordering
Article types
Others

  1. Home
  2. Keyword: Tomography, Emission-Computed, Single-Photon/methods
Figure 1
ABC
Original Article

Myocardial Perfusion by Coronary Computed Tomography in the Evaluation of Myocardial Ischemia: Simultaneous Stress Protocol with SPECT

Wilter dos Santos Ker et al. Daniel Gama das Neves Tiago Augusto Magalhães Alair Augusto Sarmet M. D. dos Santos … Claudio Tinoco Mesquita Marcelo Souto Nacif

Abstract

Background:

Functional assessment to rule out myocardial ischemia using coronary computed tomography angiography (CCTA) is extremely important and data on the Brazilian population are still limited.

Objective:

To assess the diagnostic performance of myocardial perfusion by CCTA in the detection of severe obstructive coronary artery disease (CAD) compared with single-photon emission computerized tomography (SPECT). To analyze the importance of anatomical knowledge to understand the presence of myocardial perfusion defects on SPECT imaging that is not identified on computed tomography (CT) scan.

Method:

A total of 35 patients were evaluated by a simultaneous pharmacologic stress protocol. Fisher’s exact test was used to compare proportions. The patients were grouped according to the presence or absence of significant CAD. The area under the ROC curve was used to identify the diagnostic performance of CCTA and SPECT in perfusion assessment. P < 0.05 values were considered statistically significant.

Results:

For detection of obstructive CAD, CT myocardial perfusion analysis yielded an area under the ROC curve of 0.84 [a 95% confidence interval (CI95%): 0.67-0.94, p < 0.001]. SPECT myocardial perfusion imaging, on the other hand, showed an AUC of 0.58 (95% CI 0.40 – 0.74, p < 0.001). In this study, false-positive results with SPECT are described.

Conclusion:

Myocardial perfusion analysis by CTA displays satisfactory results compared to SPECT in the detection of obstructive CAD. CCTA can rule out false-positive results of SPECT.

  • Cineangiography/methods
  • Coronary Artery Disease/physiopathology
  • Myocardial Ischemia
  • Myocardial Perfusion Imaging
  • Tomography, Emission-Computed, Single-Photon/methods
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
03/10/2019 DOI: 10.5935/abc.20190201 Views 1
Figure 1
IJCS
Case Report

Quantification of Myocardial Ischemia: Comparison between Myocardial SPECT and 13NH3 PET/TC

Angelica Mazzoletti et al. Francesco Dondi Maria Gazzilli Raffaele Giubbini

Introduction

Myocardial perfusion is a very important tool to diagnose and quantify hypoperfusion related to coronary artery disease (CAD). Single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is a widely available nuclear medicine imaging tool. Cardiac 13N-ammonia positron emission tomography/computed tomography (13NH3 PET/CT) has increased its capability to provide quantitative measures of myocardial blood flow at rest and under stress, as well as of coronary flow reserve (CFR), in addition to better image quality.

[…]

  • Coronary Artery Disease/diagnostic imaging
  • Myocardial Ischemia/diagnosis
  • Positron-Emission Tomography/method
  • Tomography, Emission-Computed, Single-Photon/methods
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
08/08/2019 DOI: 10.5935/2359-4802.20190035 Views 2

How to cite this article

EndNote RIS

Electronic Document Format (Vancouver)

Ker WS, Neves DG, Magalhães TA, Santos AASMD, Mesquita CT, Nacif MS. Myocardial Perfusion by Coronary Computed Tomography in the Evaluation of Myocardial Ischemia: Simultaneous Stress Protocol with SPECT. Arquivos Brasileiros de Cardiologia 2019;113(6):1092-101.

Electronic Document Format (ABNT)

Ker, Wilter dos Santos; Neves, Daniel Gama das; Magalhães, Tiago Augusto; Santos, Alair Augusto Sarmet M. D. dos; Mesquita, Claudio Tinoco; Nacif, Marcelo Souto. Myocardial Perfusion by Coronary Computed Tomography in the Evaluation of Myocardial Ischemia: Simultaneous Stress Protocol with SPECT. Arquivos Brasileiros de Cardiologia, v. 113, n. 6, p. 1092-1101, Oct. 2019.

Electronic Document Format (APA)

Ker, W. S., Neves, D. G. , Magalhães, T. A., Santos, A. A. S. M. D. , Mesquita, C. T., & Nacif, M. S. (2019). Myocardial Perfusion by Coronary Computed Tomography in the Evaluation of Myocardial Ischemia: Simultaneous Stress Protocol with SPECT. Arquivos Brasileiros de Cardiologia, 113(6), 1092-1101.

Electronic Document Format (ISO)

Ker, Wilter dos Santos and Neves, Daniel Gama das and Magalhães, Tiago Augusto and Santos, Alair Augusto Sarmet M. D. dos and Mesquita, Claudio Tinoco and Nacif, Marcelo Souto. Myocardial Perfusion by Coronary Computed Tomography in the Evaluation of Myocardial Ischemia: Simultaneous Stress Protocol with SPECT. Arquivos Brasileiros de Cardiologia [online]. 2019, vol. 113, n. 6, [cited 2026-10-14], pp. 1092-1101. Available from: <https://journals.cardiol.br/en/article/myocardial-perfusion-by-coronary-computed-tomography-in-the-evaluation-of-myocardial-ischemia-simultaneous-stress-protocol-with-spect/>. ISSN 0066-782X

EndNote RIS

Electronic Document Format (Vancouver)

Mazzoletti A, Dondi F, Gazzilli M, Giubbini R. Quantification of Myocardial Ischemia: Comparison between Myocardial SPECT and 13NH3 PET/TC. International Journal of Cardiovascular Sciences 2019;33(2):188-91.

Electronic Document Format (ABNT)

Mazzoletti, Angelica; Dondi, Francesco; Gazzilli, Maria; Giubbini, Raffaele. Quantification of Myocardial Ischemia: Comparison between Myocardial SPECT and 13NH3 PET/TC. International Journal of Cardiovascular Sciences, v. 33, n. 2, p. 188-191, Aug. 2019.

Electronic Document Format (APA)

Mazzoletti, A., Dondi, F., Gazzilli, M., & Giubbini, R. (2019). Quantification of Myocardial Ischemia: Comparison between Myocardial SPECT and 13NH3 PET/TC. International Journal of Cardiovascular Sciences, 33(2), 188-191.

Electronic Document Format (ISO)

Mazzoletti, Angelica and Dondi, Francesco and Gazzilli, Maria and Giubbini, Raffaele. Quantification of Myocardial Ischemia: Comparison between Myocardial SPECT and 13NH3 PET/TC. International Journal of Cardiovascular Sciences [online]. 2019, vol. 33, n. 2, [cited 2026-10-14], pp. 188-191. Available from: <https://journals.cardiol.br/en/article/quantification-of-myocardial-ischemia-comparison-between-myocardial-spect-and-13nh3-pet-tc/>. ISSN 2359-4802

  • About ABC Family
  • Internal Regulation
  • Editorial Board
  • Brazilian Society of Cardiology (SBC)

Issues

SBC Guidelines

  • Videos
  • Podcasts
  • News