ABC Family Arquivos Brasileiros de Cardiologia International Journal of Cardiovascular Sciences ABC Heart Failure & Cardiomyopathy ABC Imagem Cardiovascular
Português English
  • ABC Family
  • Arquivos Brasileiros de Cardiologia
  • International Journal of Cardiovascular Sciences
  • ABC Heart Failure & Cardiomyopathy
  • ABC Imagem Cardiovascular
Português English
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
Search in

No content found.

Journals
Ordering
Article types
Others

  1. Home
  2. Aortic Valve Insufficiency/diagnostic imaging
Figure 1
ABC
Original Article

The Role of Quantitative Aortographic Assessment of Aortic Regurgitation by Videodensitometry in the Guidance of Transcatheter Aortic Valve Implantation

Yosuke Miyazaki et al. Rodrigo Modolo Mohammad Abdelghani Hiroki Tateishi … Rafael Cavalcante Carlos Collet Taku Asano Yuki Katagiri Erhan Tenekecioglu Rogério Sarmento-Leite José A. Mangione Alexandre Abizaid Osama I.I. Soliman Yoshinobu Onuma Patrick W. Serruys Pedro A. Lemos Fabio S. de Brito Jr.

Abstract

Background:

Balloon post-dilatation (BPD) is often needed for optimizing transcatheter heart valve (THV) implantation, since paravalvular leak (PVL) after transcatheter aortic valve implantation is associated with poor outcome and mortality. Quantitative assessment of PVL severity before and after BPD is mandatory to properly assess PVL, thus improving implantation results and outcomes.

Objective:

To investigate a quantitative angiographic assessment of aortic regurgitation (AR) by videodensitometry before and after BPD.

Methods:

Videodensitometric-AR assessments (VD-AR) before and after BPD were analysed in 61 cases.

Results:

VD-AR decreased significantly from 24.0[18.0-30.5]% to 12.0[5.5-19.0]% (p < 0.001, a two-tailed p 17%) was observed in 47 patients (77%) before and in 19 patients (31%) after BPD.

Conclusions:

VD-AR after THV implantation provides a quantitative assessment of post-TAVI regurgitation and can help in the decision-making process on performing BPD and in determining its efficacy.

  • Angiography/evaluation
  • Aortic Valve Insufficiency/diagnostic imaging
  • Heart Valve Prosthesis Implantation
  • Transcatheter Aortic Valve Replacement
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
01/08/2018 DOI: 10.5935/abc.20180139 Views 11
ABC
Editorial

New Method Improves the Assessment of Aortic Regurgitation Grade during TAVR by Aortography

Henrique B. Ribeiro

Transcatheter aortic valve replacement (TAVR) is a rapidly expanding alternative to surgical aortic valve replacement for patients deemed inoperable or at high or intermediate operative risk. Yet, residual aortic regurgitation (AR) secondary to paravalvular leaks (PVL) remains a procedural limitation. Although residual AR after TAVR is frequent, affecting up to approximately 70% of the treated patients,– it is moderate to severe in approximately 12% of these and steadily below 5% with current-generation devices, which come with specific sealing features. Noteworthy, moderate/severe AR has a detrimental clinical impact after TAVR, with a 3-fold increase in 30-day mortality and a 2.3-fold increase in 1-year mortality. Thus, its accurate assessment and quantification with a multimodality approach is key for appropriate utilization of additional procedures to reduce PVL, such as balloon post-dilatation (BPD), valve-in-valve, or leak closure.,

While Doppler echocardiography has been the most common method to assess AR following TAVR, its accurate quantification is challenging since AR jets are often multiple and eccentric.,– Therefore, other methods for proper AR assessment have been evaluated in recent years, such as 3D echocardiography, hemodynamic AR index, aortography and even cardiovascular magnetic resonance, each one with its specific advantages and disadvantages.,,

[…]

  • Aortic Valve Insufficiency/diagnostic imaging
  • Aortic Valve Insufficiency/mortality
  • Aortography/methods
  • Echocardiography, Three Dimensional / methods
  • Transcatheter Aortic Valve Replacement/methods
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
01/08/2018 DOI: 10.5935/abc.20180158 Views 10

How to cite this article

EndNote RIS

Electronic Document Format (Vancouver)

Miyazaki Y, Modolo R, Abdelghani M, Tateishi H, Cavalcante R, Collet C, Asano T, et al. The Role of Quantitative Aortographic Assessment of Aortic Regurgitation by Videodensitometry in the Guidance of Transcatheter Aortic Valve Implantation. Arquivos Brasileiros de Cardiologia 2018;111(2):193-202.

Electronic Document Format (ABNT)

Miyazaki, Yosuke; Modolo, Rodrigo; Abdelghani, Mohammad; Tateishi, Hiroki; Cavalcante, Rafael; Collet, Carlos; Asano, Taku; Katagiri, Yuki; Tenekecioglu, Erhan; Sarmento-Leite, Rogério; Mangione, José A.; Abizaid, Alexandre; Soliman, Osama I.I.; Onuma, Yoshinobu; Serruys, Patrick W.; Lemos, Pedro A.; Brito Jr., Fabio S. de. The Role of Quantitative Aortographic Assessment of Aortic Regurgitation by Videodensitometry in the Guidance of Transcatheter Aortic Valve Implantation. Arquivos Brasileiros de Cardiologia, v. 111, n. 2, p. 193-202, Jul. 2018.

Electronic Document Format (APA)

Miyazaki, Y., Modolo, R., Abdelghani, M., Tateishi, H., Cavalcante, R., Collet, C., Asano, T., Katagiri, Y., Tenekecioglu, E., Sarmento-Leite, R., Mangione, J. A., Abizaid, A., Soliman, O. I., Onuma, Y., Serruys, P. W., Lemos, P. A., & Brito Jr., F. S. (2018). The Role of Quantitative Aortographic Assessment of Aortic Regurgitation by Videodensitometry in the Guidance of Transcatheter Aortic Valve Implantation. Arquivos Brasileiros de Cardiologia, 111(2), 193-202.

Electronic Document Format (ISO)

Miyazaki, Yosuke and Modolo, Rodrigo and Abdelghani, Mohammad and Tateishi, Hiroki and Cavalcante, Rafael and Collet, Carlos and Asano, Taku and Katagiri, Yuki and Tenekecioglu, Erhan and Sarmento-Leite, Rogério and Mangione, José A. and Abizaid, Alexandre and Soliman, Osama I.I. and Onuma, Yoshinobu and Serruys, Patrick W. and Lemos, Pedro A. and Brito Jr., Fabio S. de. The Role of Quantitative Aortographic Assessment of Aortic Regurgitation by Videodensitometry in the Guidance of Transcatheter Aortic Valve Implantation. Arquivos Brasileiros de Cardiologia [online]. 2018, vol. 111, n. 2, [cited 2026-11-28], pp. 193-202. Available from: <https://journals.cardiol.br/en/article/the-role-of-quantitative-aortographic-assessment-of-aortic-regurgitation-by-videodensitometry-in-the-guidance-of-transcatheter-aortic-valve-implantation/>. ISSN 0066-782X

EndNote RIS

Electronic Document Format (Vancouver)

Ribeiro HB. New Method Improves the Assessment of Aortic Regurgitation Grade during TAVR by Aortography. Arquivos Brasileiros de Cardiologia 2018;111(2):203-4.

Electronic Document Format (ABNT)

Ribeiro, Henrique B.. New Method Improves the Assessment of Aortic Regurgitation Grade during TAVR by Aortography. Arquivos Brasileiros de Cardiologia, v. 111, n. 2, p. 203-204, Jul. 2018.

Electronic Document Format (APA)

Ribeiro, H. B. (2018). New Method Improves the Assessment of Aortic Regurgitation Grade during TAVR by Aortography. Arquivos Brasileiros de Cardiologia, 111(2), 203-204.

Electronic Document Format (ISO)

Ribeiro, Henrique B.. New Method Improves the Assessment of Aortic Regurgitation Grade during TAVR by Aortography. Arquivos Brasileiros de Cardiologia [online]. 2018, vol. 111, n. 2, [cited 2026-11-28], pp. 203-204. Available from: <https://journals.cardiol.br/en/article/new-method-improves-the-assessment-of-aortic-regurgitation-grade-during-tavr-by-aortography/>. ISSN 0066-782X

  • About ABC Family
  • Internal Regulation
  • Editorial Board
  • Brazilian Society of Cardiology (SBC)

Issues

SBC Guidelines

  • Videos
  • Podcasts
  • News
Accessibility Adjustments

Powered by OneTap

How long do you want to hide the toolbar?
Hide Toolbar Duration
Select your accessibility profile
Vision Impaired Mode
Enhances website's visuals
Seizure Safe Profile
Clear flashes & reduces color
ADHD Friendly Mode
Focused browsing, distraction-free
Blindness Mode
Reduces distractions, improves focus
Epilepsy Safe Mode
Dims colors and stops blinking
Content Modules
Font Size

Default

Line Height

Default

Color Modules
Orientation Modules