Safety and feasibility of dobutamine-atropine stress echocardiography

PURPOSE: To study the safety and feasibility of dobutamine-atropine stress echocardiography (DASE) in patients with known or suspected coronary artery disease. METHODS: There were 3,000 DASE that were studied in a prospective fashion. All symptons and side effects were stored in a data base format. RESULTS: Major test-related complications observed included one case of myocardial infarction, four cases of sustained ventricular tachycardia and five cases of atropine intoxication. There was no death or ventricular fibrillation as a direct or indirect consequence of the test. The infusion protocol allowed to us to examine patients using beta blockers, and led to 95% feasibility. CONCLUSION: DASE is a safe and feasible method for the study of patients with suspected or known coronary artery disease.