ABC Family Arquivos Brasileiros de Cardiologia International Journal of Cardiovascular Sciences ABC Heart Failure & Cardiomyopathy ABC Imagem Cardiovascular
Português English
ABC Family
Português English
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News

ABC Family

  • ABC Family
  • Arquivos Brasileiros de Cardiologia
  • International Journal of Cardiovascular Sciences
  • ABC Heart Failure & Cardiomyopathy
  • ABC Imagem Cardiovascular
Search in

No content found.

Journals
Ordering
Article types
Others

  1. Home
  2. Keyword: Heart Valves / physiopathology
Figure 1
ABC
Original Article

An Alternative Method to Calculate Simplified Projected Aortic Valve Area at Normal Flow Rate

Joana Sofia Silva Moura Ferreira et al. Nádia Moreira Rita Ferreira Sofia Mendes … Rui Martins Maria João Ferreira Mariano Pego

Abstract

Background:

Simplified projected aortic valve area (EOAproj) is a valuable echocardiographic parameter in the evaluation of low flow low gradient aortic stenosis (LFLG AS). Its widespread use in clinical practice is hampered by the laborious process of flow rate (Q) calculation.

Objetive:

This study proposes a less burdensome, alternative method of Q calculation to be incorporated in the original formula of EOAproj and measures the agreement between the new proposed method of EOAproj calculation and the original one.

Methods:

Retrospective observational single-institution study that included all consecutive patients with classic LFLG AS that showed a Q variation with dobutamine infusion ≥ |15|% by both calculation methods.

Results:

Twenty-two consecutive patients with classical LFLG AS who underwent dobutamine stress echocardiography were included. Nine patients showed a Q variation with dobutamine infusion calculated by both classical and alternative methods ≥ |15|% and were selected for further statistical analysis. Using the Bland-Altman method to assess agreement we found a systematic bias of 0,037 cm2 (95% CI 0,004 – 0,066), meaning that on average the new method overestimates the EOAproj in 0,037 cm2 compared to the original method. The 95% limits of agreement are narrow (from -0,04 cm2 to 0,12 cm2), meaning that for 95% of individuals, EOAproj calculated by the new method would be between 0,04 cm2 less to 0,12 cm2 more than the EOAproj calculated by the original equation.

Conclusion:

The bias and 95% limits of agreement of the new method are narrow and not clinically relevant, supporting the potential interchangeability of the two methods of EOAproj calculation. As the new method requires less additional measurements, it would be easier to implement in clinical practice, promoting an increase in the use of EOAproj.

  • Aortic Valve Stenosis / diagnosis
  • Aortic Valve Stenosis / diagnostic imaging
  • Echocardiography, Stress
  • Heart Valves / physiopathology
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
01/02/2018 DOI: 10.5935/abc.20180018 Views 1

How to cite this article

EndNote RIS

Electronic Document Format (Vancouver)

Ferreira JSSM, Moreira N, Ferreira R, Mendes S, Martins R, Ferreira MJ, Pego M, et al. An Alternative Method to Calculate Simplified Projected Aortic Valve Area at Normal Flow Rate. Arquivos Brasileiros de Cardiologia 2018;110(2):132-9.

Electronic Document Format (ABNT)

Ferreira, Joana Sofia Silva Moura; Moreira, Nádia; Ferreira, Rita; Mendes, Sofia; Martins, Rui; Ferreira, Maria João; Pego, Mariano. An Alternative Method to Calculate Simplified Projected Aortic Valve Area at Normal Flow Rate. Arquivos Brasileiros de Cardiologia, v. 110, n. 2, p. 132-139, Jan. 2018.

Electronic Document Format (APA)

Ferreira, J. S. S. M., Moreira, N., Ferreira, R., Mendes, S., Martins, R., Ferreira, M. J., & Pego, M. (2018). An Alternative Method to Calculate Simplified Projected Aortic Valve Area at Normal Flow Rate. Arquivos Brasileiros de Cardiologia, 110(2), 132-139.

Electronic Document Format (ISO)

Ferreira, Joana Sofia Silva Moura and Moreira, Nádia and Ferreira, Rita and Mendes, Sofia and Martins, Rui and Ferreira, Maria João and Pego, Mariano. An Alternative Method to Calculate Simplified Projected Aortic Valve Area at Normal Flow Rate. Arquivos Brasileiros de Cardiologia [online]. 2018, vol. 110, n. 2, [cited 2026-10-14], pp. 132-139. Available from: <https://journals.cardiol.br/en/article/an-alternative-method-to-calculate-simplified-projected-aortic-valve-area-at-normal-flow-rate/>. ISSN 0066-782X

  • About ABC Family
  • Internal Regulation
  • Editorial Board
  • Brazilian Society of Cardiology (SBC)

Issues

SBC Guidelines

  • Videos
  • Podcasts
  • News