ABC Family Arquivos Brasileiros de Cardiologia International Journal of Cardiovascular Sciences ABC Heart Failure & Cardiomyopathy ABC Imagem Cardiovascular
Português English
ABC Family
Português English
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News

ABC Family

  • ABC Family
  • Arquivos Brasileiros de Cardiologia
  • International Journal of Cardiovascular Sciences
  • ABC Heart Failure & Cardiomyopathy
  • ABC Imagem Cardiovascular
Search in

No content found.

Journals
Ordering
Article types
Others

  1. Home
  2. Keyword: Defibrilators
ABC
Original Article

Comparative Study between Subcutaneous and Endovascular Defibrillator Recipients Regarding Tolerance to the Implant Procedure and Perception of Quality of Life

Pablo Esteban Auquilla-Clavijo et al. Naiara Calvo-Galiano Marina Povar-Echeverría Teresa Oloriz-Sanjuan … Francisco Diaz-Cortejana Antonio Asso-Abadia

Abstract

Background

The totally subcutaneous implantable cardioverter-defibrillator (S-ICD) is a safe alternative to the conventional transvenous ICD (TV-ICD) system to prevent sudden death.

Objective

To compare the impact of the type of ICD system and surgical technique on patients’ quality of life, as well as the severity of discomfort and pain, between S-ICD and TV-ICD recipients.

Methods

Consecutively implanted patients with an S-ICD system were matched with patients with a TV-ICD system. In addition, patients undergoing S-ICD implantation after removal of a TV-ICD due to complications were included. Quality of life (measured with the 12-item short-form health survey) and severity of pain and discomfort were evaluated. Statistical significance was defined as p < 0.05.

Results

A total of 64 patients implanted with S-ICD or TV-ICD under local anesthesia and conscious sedation were analyzed. Patients with S-ICD and TV-ICD systems did not differ significantly in quality of life scores. S-ICD patients had a higher level of perioperative pain; no differences were found regarding severity of intraoperative pain. The magnitude of aesthetic discomfort and sleep disturbances did not differ between groups. An S-ICD was implanted in 7 additional patients after removal of a TV-ICD. All but one of these patients recommended the S-ICD system.

Conclusions

The type of ICD system and the surgical technique have negligible impact on patients’ quality of life. These results suggest that conscious sedation, provided by an experienced electrophysiology team, could be considered as an alternative to general anesthesia to manage patients undergoing S-ICD implantation.

  • Comparative Study
  • Conscious Sedation
  • Defibrilators
  • Defibrillators Subcutaneous Implantable
  • Implantable
  • Quality of life
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
14/06/2021 DOI: 10.36660/abc.20190312

How to cite this article

EndNote RIS

Electronic Document Format (Vancouver)

Auquilla-Clavijo PE, Calvo-Galiano N, Povar-Echeverría M, Oloriz-Sanjuan T, Diaz-Cortejana F, Asso-Abadia A. Comparative Study between Subcutaneous and Endovascular Defibrillator Recipients Regarding Tolerance to the Implant Procedure and Perception of Quality of Life. Arquivos Brasileiros de Cardiologia 2021;116(6):1139-48.

Electronic Document Format (ABNT)

Auquilla-Clavijo, Pablo Esteban; Calvo-Galiano, Naiara; Povar-Echeverría, Marina; Oloriz-Sanjuan, Teresa; Diaz-Cortejana, Francisco; Asso-Abadia, Antonio. Comparative Study between Subcutaneous and Endovascular Defibrillator Recipients Regarding Tolerance to the Implant Procedure and Perception of Quality of Life. Arquivos Brasileiros de Cardiologia, v. 116, n. 6, p. 1139-1148, Jun. 2021.

Electronic Document Format (APA)

Auquilla-Clavijo, P. E., Calvo-Galiano, N., Povar-Echeverría, M., Oloriz-Sanjuan, T., Diaz-Cortejana, F., & Asso-Abadia, A. (2021). Comparative Study between Subcutaneous and Endovascular Defibrillator Recipients Regarding Tolerance to the Implant Procedure and Perception of Quality of Life. Arquivos Brasileiros de Cardiologia, 116(6), 1139-1148.

Electronic Document Format (ISO)

Auquilla-Clavijo, Pablo Esteban and Calvo-Galiano, Naiara and Povar-Echeverría, Marina and Oloriz-Sanjuan, Teresa and Diaz-Cortejana, Francisco and Asso-Abadia, Antonio. Comparative Study between Subcutaneous and Endovascular Defibrillator Recipients Regarding Tolerance to the Implant Procedure and Perception of Quality of Life. Arquivos Brasileiros de Cardiologia [online]. 2021, vol. 116, n. 6, [cited 2026-10-14], pp. 1139-1148. Available from: <https://journals.cardiol.br/en/article/comparative-study-between-subcutaneous-and-endovascular-defibrillator-recipients-regarding-tolerance-to-the-implant-procedure-and-perception-of-quality-of-life/>. ISSN 0066-782X

  • About ABC Family
  • Internal Regulation
  • Editorial Board
  • Brazilian Society of Cardiology (SBC)

Issues

SBC Guidelines

  • Videos
  • Podcasts
  • News