ABC Family Arquivos Brasileiros de Cardiologia International Journal of Cardiovascular Sciences ABC Heart Failure & Cardiomyopathy ABC Imagem Cardiovascular
Português English
ABC Family
Português English
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News

ABC Family

  • ABC Family
  • Arquivos Brasileiros de Cardiologia
  • International Journal of Cardiovascular Sciences
  • ABC Heart Failure & Cardiomyopathy
  • ABC Imagem Cardiovascular
Search in

No content found.

Journals
Ordering
Article types
Others

  1. Home
  2. Keyword: interventional catheterization
Clinical efficacy and safety of the percutaneous treatment of secundum atrial septal defect with the Amplatzer occluder
ABC
Artigo Original

Clinical efficacy and safety of the percutaneous treatment of secundum atrial septal defect with the Amplatzer occluder

Sérgio Luiz Navarro Braga et al. Amanda Guerra de Moraes Rego Sousa Carlos Augusto Cardoso Pedra César Augusto Esteves … Simone Rolim Fernandes Fontes Pedra Valmir Fernandes Fontes

OBJECTIVE: To assess the clinical efficacy and safety of the Amplatzer occluder for percutaneous closure of secundum atrial septal defect. METHODS: Forty-nine patients underwent the procedure guided by transesophageal echocardiography (TEE) while under general anesthesia, afterwards being clinically followed up for 12 months. RESULTS: The defect presented as a single orifice in 91.8% of the cases. The means of the longitudinal and transverse diameters were 14.3±5.0 mm and 14.4±4.9 mm, respectively. The means of the stretched diameters and prostheses were 19.3±5.1 mm and 20.3±4.9 mm, respectively. Technical success occurred in 97.9% of the cases. Immediate residual flow was observed in 54.1% of the patients, being minimum or small in 45.8% and moderate in 8.3%. After 24 hours, residual flow was observed in 25% of the patients (P = 0.0002). At the end of 13.1±1.3 months, the incidence of the overall residual flow decreased to 14.6%, only 4.1% being moderate. A significant reduction in the right ventricular diastolic diameter was observed in the different phases of clinical follow-up (P < 0.001). CONCLUSION: Implantation of the Amplatzer prosthesis proved to be effective and safe, constituting an option for the treatment of the secundum atrial septal defect in selected cases.

  • Amplatzer occluder
  • atrial septal defect
  • congenital heart diseases
  • interventional catheterization
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
13/12/2004 DOI: 10.1590/S0066-782X2004001900003 Views 1
Short- and midterm follow-up results of valvuloplasty with balloon catheter for congenital aortic stenosis
ABC
Original Article

Short- and midterm follow-up results of valvuloplasty with balloon catheter for congenital aortic stenosis

Carlos A. C. Pedra et al. Simone R. F. Pedra Sérgio L. N. Braga César A. Esteves … Samuel M. Moreira Magali A. dos Santos Ieda J. Bosisio Maria Aparecida P. Silva Patrícia F. Elias Maria Virgínia T. Santana Valmir F. Fontes

OBJECTIVE: To report short and midtem follow-up results of balloon aortic valvuloplasty to treat congenital aortic stenosis. METHODS: Seventy-five patients (median age: 8 years) underwent the procedure through the retrograde femoral or carotid route. RESULTS: The procedure was completed in 74 patients (98.6%). The peak-to-peak systolic gradient dropped from 79.6±27.7 to 22.3±17.8 mmHg (P<0.001), the left ventricular systolic pressure dropped from 164±39.1 to 110±24.8 mmHg (P<0.001), and the left ventricular end diastolic pressure dropped from 13.3±5.5 to 8.5±8.3 mmHg (P< 0.01). Four patients (5.3%) died due to the procedure. Aortic regurgitation (AoR) appeared or worsened in 27/71 (38%) patients, and no immediate surgical intervention was required. A mean follow-up of 50±38 months was obtained in 37 patients. Restenosis and significant AoR were observed in 16.6% of the patients. The estimates for being restenosis-free and for having significant AoR in 90 months were 60% and 50%, respectively. CONCLUSION: Aortic valvuloplasty was considered the initial palliative method of choice in managing congenital aortic stenosis, with satisfactory short- and midterm results.

  • aortic valvuloplasty
  • congenital aortic stenosis
  • interventional catheterization
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
16/09/2003 DOI: 10.1590/S0066-782X2003001000001

How to cite this article

EndNote RIS

Electronic Document Format (Vancouver)

Braga SLN, Sousa AGMR, Pedra CAC, Esteves CA, Pedra SRFF, Fontes VF. Clinical efficacy and safety of the percutaneous treatment of secundum atrial septal defect with the Amplatzer occluder. Arquivos Brasileiros de Cardiologia 2004;83(spe):7-13.

Electronic Document Format (ABNT)

Braga, Sérgio Luiz Navarro; Sousa, Amanda Guerra de Moraes Rego; Pedra, Carlos Augusto Cardoso; Esteves, César Augusto; Pedra, Simone Rolim Fernandes Fontes; Fontes, Valmir Fernandes. Clinical efficacy and safety of the percutaneous treatment of secundum atrial septal defect with the Amplatzer occluder. Arquivos Brasileiros de Cardiologia, v. 83, n. spe, p. 7-13, Dec. 2004.

Electronic Document Format (APA)

Braga, S. L. N., Sousa, A. G. M. R., Pedra, C. A. C., Esteves, C. A., Pedra, S. R. F. F., & Fontes, V. F. (2004). Clinical efficacy and safety of the percutaneous treatment of secundum atrial septal defect with the Amplatzer occluder. Arquivos Brasileiros de Cardiologia, 83(spe), 7-13.

Electronic Document Format (ISO)

Braga, Sérgio Luiz Navarro and Sousa, Amanda Guerra de Moraes Rego and Pedra, Carlos Augusto Cardoso and Esteves, César Augusto and Pedra, Simone Rolim Fernandes Fontes and Fontes, Valmir Fernandes. Clinical efficacy and safety of the percutaneous treatment of secundum atrial septal defect with the Amplatzer occluder. Arquivos Brasileiros de Cardiologia [online]. 2004, vol. 83, n. spe, [cited 2026-10-14], pp. 7-13. Available from: <https://journals.cardiol.br/en/article/clinical-efficacy-and-safety-of-the-percutaneous-treatment-of-secundum-atrial-septal-defect-with-the-amplatzer-occluder/>. ISSN 0066-782X

EndNote RIS

Electronic Document Format (Vancouver)

Pedra CAC, Pedra SRF, Braga SLN, Esteves CA, Moreira SM, Santos MA, Bosisio IJ, et al. Short- and midterm follow-up results of valvuloplasty with balloon catheter for congenital aortic stenosis. Arquivos Brasileiros de Cardiologia 2003;81(2):120-8.

Electronic Document Format (ABNT)

Pedra, Carlos A. C.; Pedra, Simone R. F.; Braga, Sérgio L. N.; Esteves, César A.; Moreira, Samuel M.; Santos, Magali A. dos; Bosisio, Ieda J.; Silva, Maria Aparecida P.; Elias, Patrícia F.; Santana, Maria Virgínia T.; Fontes, Valmir F.. Short- and midterm follow-up results of valvuloplasty with balloon catheter for congenital aortic stenosis. Arquivos Brasileiros de Cardiologia, v. 81, n. 2, p. 120-128, Sep. 2003.

Electronic Document Format (APA)

Pedra, C. A. C., Pedra, S. R. F., Braga, S. L. N., Esteves, C. A., Moreira, S. M., Santos, M. A. , Bosisio, I. J., Silva, M. A. P., Elias, P. F., Santana, M. V. T., & Fontes, V. F. (2003). Short- and midterm follow-up results of valvuloplasty with balloon catheter for congenital aortic stenosis. Arquivos Brasileiros de Cardiologia, 81(2), 120-128.

Electronic Document Format (ISO)

Pedra, Carlos A. C. and Pedra, Simone R. F. and Braga, Sérgio L. N. and Esteves, César A. and Moreira, Samuel M. and Santos, Magali A. dos and Bosisio, Ieda J. and Silva, Maria Aparecida P. and Elias, Patrícia F. and Santana, Maria Virgínia T. and Fontes, Valmir F.. Short- and midterm follow-up results of valvuloplasty with balloon catheter for congenital aortic stenosis. Arquivos Brasileiros de Cardiologia [online]. 2003, vol. 81, n. 2, [cited 2026-10-14], pp. 120-128. Available from: <https://journals.cardiol.br/en/article/short-and-midterm-follow-up-results-of-valvuloplasty-with-balloon-catheter-for-congenital-aortic-stenosis/>. ISSN 0066-782X

  • About ABC Family
  • Internal Regulation
  • Editorial Board
  • Brazilian Society of Cardiology (SBC)

Issues

SBC Guidelines

  • Videos
  • Podcasts
  • News