ABC Family Arquivos Brasileiros de Cardiologia International Journal of Cardiovascular Sciences ABC Heart Failure & Cardiomyopathy ABC Imagem Cardiovascular
Português English
ABC Family
Português English
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News

ABC Family

  • ABC Family
  • Arquivos Brasileiros de Cardiologia
  • International Journal of Cardiovascular Sciences
  • ABC Heart Failure & Cardiomyopathy
  • ABC Imagem Cardiovascular
Search in

No content found.

Journals
Ordering
Article types
Others

  1. Home
  2. Keyword: Cost Savings/economic
Figure 1
ABC
Original Article

Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs

Joan Costa-Mateu et al. Diego Fernández-Rodríguez Kristian Rivera Juan Casanova … Patricia Irigaray Marta Zielonka Eduardo Pereyra-Acha Albina Aldomá Fernando Worner

Abstract

Background:

Coronary angiography with two catheters is the traditional strategy for diagnostic coronary procedures. TIG I catheter permits to cannulate both coronary arteries, avoiding exchanging catheters during coronary angiography by transradial access.

Objective:

The aim of this study is to evaluate the impact of one-catheter strategy, by avoiding catheter exchange, on coronary catheterization performance and economic costs.

Methods:

Transradial coronary diagnostic procedures conducted from January 2013 to June 2017 were collected. One-catheter strategy (TIG I catheter) and two-catheter strategy (left and right Judkins catheters) were compared. The volume of iodinated contrast administered was the primary endpoint. Secondary endpoints included radial spasm, procedural duration (fluoroscopy time) and exposure to ionizing radiation (dose-area product and air kerma). Direct economic costs were also evaluated. For statistical analyses, two-tailed p-values < 0.05 were considered statistically significant.

Results:

From a total of 1,953 procedures in 1,829 patients, 252 procedures were assigned to one-catheter strategy and 1,701 procedures to two-catheter strategy. There were no differences in baseline characteristics between the groups. One-catheter strategy required less iodinated contrast [primary endpoint; (60-105)-mL vs. 92 (64-120)-mL; p < 0.001] than the two-catheter strategy. Also, the one-catheter group presented less radial spasm (5.2% vs. 9.3%, p = 0.022) and shorter fluoroscopy time [3.9 (2.2-8.0)-min vs. 4.8 (2.9-8.3)-min, p = 0.001] and saved costs [149 (140-160)-€/procedure vs. 171 (160-183)-€/procedure; p < 0.001]. No differences in dose-area product and air kerma were detected between the groups.

Conclusions:

One-catheter strategy, with TIG I catheter, improves coronary catheterization performance and reduces economic costs compared to traditional two-catheter strategy in patients referred for coronary angiography.

  • Cardiac Catheterization/economic
  • Cineagiography/methods
  • Cost Savings/economic
  • Fluoroscopy
  • Radiation, Ionizing;
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
02/12/2019 DOI: 10.5935/abc.20190232 Views 1

How to cite this article

EndNote RIS

Electronic Document Format (Vancouver)

Costa-Mateu J, Fernández-Rodríguez D, Rivera K, Casanova J, Irigaray P, Zielonka M, Pereyra-Acha E, et al. Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs. Arquivos Brasileiros de Cardiologia 2019;113(5):960-8.

Electronic Document Format (ABNT)

Costa-Mateu, Joan; Fernández-Rodríguez, Diego; Rivera, Kristian; Casanova, Juan; Irigaray, Patricia; Zielonka, Marta; Pereyra-Acha, Eduardo; Aldomá, Albina; Worner, Fernando. Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs. Arquivos Brasileiros de Cardiologia, v. 113, n. 5, p. 960-968, Dec. 2019.

Electronic Document Format (APA)

Costa-Mateu, J., Fernández-Rodríguez, D., Rivera, K., Casanova, J., Irigaray, P., Zielonka, M., Pereyra-Acha, E., Aldomá, A., & Worner, F. (2019). Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs. Arquivos Brasileiros de Cardiologia, 113(5), 960-968.

Electronic Document Format (ISO)

Costa-Mateu, Joan and Fernández-Rodríguez, Diego and Rivera, Kristian and Casanova, Juan and Irigaray, Patricia and Zielonka, Marta and Pereyra-Acha, Eduardo and Aldomá, Albina and Worner, Fernando. Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs. Arquivos Brasileiros de Cardiologia [online]. 2019, vol. 113, n. 5, [cited 2026-10-14], pp. 960-968. Available from: <https://journals.cardiol.br/en/article/impact-of-one-catheter-strategy-with-tig-i-catheter-on-coronary-catheterization-performance-and-economic-costs/>. ISSN 0066-782X

  • About ABC Family
  • Internal Regulation
  • Editorial Board
  • Brazilian Society of Cardiology (SBC)

Issues

SBC Guidelines

  • Videos
  • Podcasts
  • News