ABC Family Arquivos Brasileiros de Cardiologia International Journal of Cardiovascular Sciences ABC Heart Failure & Cardiomyopathy ABC Imagem Cardiovascular
Português English
ABC Family
Português English
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News

ABC Family

  • ABC Family
  • Arquivos Brasileiros de Cardiologia
  • International Journal of Cardiovascular Sciences
  • ABC Heart Failure & Cardiomyopathy
  • ABC Imagem Cardiovascular
Search in

No content found.

Journals
Ordering
Article types
Others

  1. Home
  2. Keyword: calibration accuracy
The results of the Campaign for evaluating sphygmomanometers accuracy and their physical conditions
ABC
Original Article

The results of the Campaign for evaluating sphygmomanometers accuracy and their physical conditions

Décio Mion Jr et al. Angela M. G. Pierin Débora Cristina Alavarce José Henrique da Cunha Vasconcellos

OBJECTIVE: To evaluate the sphygmomanometers calibration accuracy and the physical conditions of the cuff-bladder, bulb, pump, and valve. METHODS: Sixty hundred and forty five aneroid sphygmomanometers were evaluated, 521 used in private practice and 124 used in hospitals. Aneroid manometers were tested against a properly calibrated mercury manometer and were considered calibrated when the error was <=3mm Hg. The physical conditions of the cuffs-bladder, bulb, pump, and valve were also evaluated. RESULTS: Of the aneroid sphygmomanometers tested, 51% of those used in private practice and 56% of those used in hospitals were found to be not accurately calibrated. Of these, the magnitude of inaccuracy ranged from 4 to 8mm Hg in 70% and 51% of the devices, respectively. The problems found in the cuffs – bladders, bulbs, pumps, and valves of the private practice and hospital devices were bladder damage (34% vs. 21%, respectively), holes/leaks in the bulbs (22% vs. 4%, respectively), and rubber aging (15% vs. 12%, respectively). Of the devices tested, 72% revealed at least one problem interfering with blood pressure measurement accuracy. CONCLUSION: Most of the manometers evaluated, whether used in private practice or in hospitals, were found to be inaccurate and unreliable, and their use may jeopardize the diagnosis and treatment of arterial hypertension.

  • blood pressure measurement
  • calibration accuracy
  • Sphygmomanometers
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
05/09/2000 DOI: 10.1590/S0066-782X2000000100004 Views 1

How to cite this article

EndNote RIS

Electronic Document Format (Vancouver)

Mion Jr D, Pierin AMG, Alavarce DC, Vasconcellos JHC. The results of the Campaign for evaluating sphygmomanometers accuracy and their physical conditions. Arquivos Brasileiros de Cardiologia 2000;74(1):35-8.

Electronic Document Format (ABNT)

Mion Jr, Décio; Pierin, Angela M. G.; Alavarce, Débora Cristina; Vasconcellos, José Henrique da Cunha. The results of the Campaign for evaluating sphygmomanometers accuracy and their physical conditions. Arquivos Brasileiros de Cardiologia, v. 74, n. 1, p. 35-38, Sep. 2000.

Electronic Document Format (APA)

Mion Jr, D., Pierin, A. M. G., Alavarce, D. C., & Vasconcellos, J. H. C. (2000). The results of the Campaign for evaluating sphygmomanometers accuracy and their physical conditions. Arquivos Brasileiros de Cardiologia, 74(1), 35-38.

Electronic Document Format (ISO)

Mion Jr, Décio and Pierin, Angela M. G. and Alavarce, Débora Cristina and Vasconcellos, José Henrique da Cunha. The results of the Campaign for evaluating sphygmomanometers accuracy and their physical conditions. Arquivos Brasileiros de Cardiologia [online]. 2000, vol. 74, n. 1, [cited 2026-10-14], pp. 35-38. Available from: <https://journals.cardiol.br/en/article/the-results-of-the-campaign-for-evaluating-sphygmomanometers-accuracy-and-their-physical-conditions/>. ISSN 0066-782X

  • About ABC Family
  • Internal Regulation
  • Editorial Board
  • Brazilian Society of Cardiology (SBC)

Issues

SBC Guidelines

  • Videos
  • Podcasts
  • News