ABC Family Arquivos Brasileiros de Cardiologia International Journal of Cardiovascular Sciences ABC Heart Failure & Cardiomyopathy ABC Imagem Cardiovascular
Português English
ABC Family
Português English
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News

ABC Family

  • ABC Family
  • Arquivos Brasileiros de Cardiologia
  • International Journal of Cardiovascular Sciences
  • ABC Heart Failure & Cardiomyopathy
  • ABC Imagem Cardiovascular
Search in

No content found.

Journals
Ordering
Article types
Others

  1. Home
  2. Keyword: Artifacts
Figure 1
ABC
Artigo Original

Subcutaneous Tissue Thickness is an Independent Predictor of Image Noise in Cardiac CT

Henrique Lane Staniak et al. Rodolfo Sharovsky Alexandre Costa Pereira Cláudio Campi de Castro … Isabela M. Benseñor Paulo A. Lotufo Márcio Sommer Bittencourt

Background:

Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist.

Objectives:

To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT.

Methods:

86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation.

Results:

The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively.

Conclusion:

Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure.

  • Artifacts
  • Computed Tomography
  • Radiation injuries
  • Sternum / radiation effects
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
01/11/2013 DOI: 10.5935/abc.20130215 Views 1

How to cite this article

EndNote RIS

Electronic Document Format (Vancouver)

Staniak HL, Sharovsky R, Pereira AC, Castro CC, Benseñor IM, Lotufo PA, Bittencourt MS, et al. Subcutaneous Tissue Thickness is an Independent Predictor of Image Noise in Cardiac CT. Arquivos Brasileiros de Cardiologia 2013;102(1):86-92.

Electronic Document Format (ABNT)

Staniak, Henrique Lane; Sharovsky, Rodolfo; Pereira, Alexandre Costa; Castro, Cláudio Campi de; Benseñor, Isabela M.; Lotufo, Paulo A.; Bittencourt, Márcio Sommer. Subcutaneous Tissue Thickness is an Independent Predictor of Image Noise in Cardiac CT. Arquivos Brasileiros de Cardiologia, v. 102, n. 1, p. 86-92, Oct. 2013.

Electronic Document Format (APA)

Staniak, H. L., Sharovsky, R., Pereira, A. C., Castro, C. C. , Benseñor, I. M., Lotufo, P. A., & Bittencourt, M. S. (2013). Subcutaneous Tissue Thickness is an Independent Predictor of Image Noise in Cardiac CT. Arquivos Brasileiros de Cardiologia, 102(1), 86-92.

Electronic Document Format (ISO)

Staniak, Henrique Lane and Sharovsky, Rodolfo and Pereira, Alexandre Costa and Castro, Cláudio Campi de and Benseñor, Isabela M. and Lotufo, Paulo A. and Bittencourt, Márcio Sommer. Subcutaneous Tissue Thickness is an Independent Predictor of Image Noise in Cardiac CT. Arquivos Brasileiros de Cardiologia [online]. 2013, vol. 102, n. 1, [cited 2026-10-14], pp. 86-92. Available from: <https://journals.cardiol.br/en/article/subcutaneous-tissue-thickness-is-an-independent-predictor-of-image-noise-in-cardiac-ct/>. ISSN 0066-782X

  • About ABC Family
  • Internal Regulation
  • Editorial Board
  • Brazilian Society of Cardiology (SBC)

Issues

SBC Guidelines

  • Videos
  • Podcasts
  • News