Relato de Caso

Coronary artery aneurysm one year and five months after sirolimus-eluting stent placement

A 52-year-old man with diagnosis of post-infarction unstable angina. Coronary angiography revealed 90% luminal obstruction in the middle third of the right coronary artery and 90% in the marginal branch of the circumflex artery. After the administration of clopidogrel 300 mg associated with acetylsalicylic acid, the patient underwent the implantation of a sirolimus-eluting stent (CYPHER; Johnson & Johnson Cordis) 2.5 x 1.8 mm in the lesion located at the left marginal branch. One year and five months after the CYPHER stent implantation, a new angiography showed intrastent coronary aneurysm at the left marginal branch. This case report suggests that the implantation of a sirolimus-coated coronary stent may cause late formation of coronary artery aneurysm.

Images

Metrics

Views 0
PlumX Metrics

Comments

0 Comments

Comments are moderated by the editorial team before publication. Discussions should be evidence-based and use scientific language. Conflicts of interest should be declared.

No comments yet.