ABC Family Arquivos Brasileiros de Cardiologia International Journal of Cardiovascular Sciences ABC Heart Failure & Cardiomyopathy ABC Imagem Cardiovascular
Português English
ABC Family
Português English
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News
  • About
    • About ABC Family
    • Internal Regulation
    • Editorial Board
    • Brazilian Society of Cardiology (SBC)
  • Issues
  • SBC Guidelines
  • Content
    • Videos
    • Podcasts
    • News

ABC Family

  • ABC Family
  • Arquivos Brasileiros de Cardiologia
  • International Journal of Cardiovascular Sciences
  • ABC Heart Failure & Cardiomyopathy
  • ABC Imagem Cardiovascular
Search in

No content found.

Journals
Ordering
Article types
Others

  1. Home
  2. Keyword: automated
Assessment of the DIXTAL DX-2710 Automated Oscillometric Device for Blood Pressure Measurement with the Validation Protocols of the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI)
ABC
Original Article

Assessment of the DIXTAL DX-2710 Automated Oscillometric Device for Blood Pressure Measurement with the Validation Protocols of the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI)

Gisele M. P. Mano et al. Viviane F. Souza Angela M. G. Pierin Josiane C. Lima … Edna C. Ignes Kátia C. Ortega Décio Mion Jr.

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: “A” for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.

  • automated
  • oscillometric blood pressure measuring device
  • validation
Read Full Article
Creative Commons Attribution (CC BY) Creative Commons license
09/01/2003 DOI: 10.1590/S0066-782X2002001500006

How to cite this article

EndNote RIS

Electronic Document Format (Vancouver)

Mano GMP, Souza VF, Pierin AMG, Lima JC, Ignes EC, Ortega KC, Mion Jr. D, et al. Assessment of the DIXTAL DX-2710 Automated Oscillometric Device for Blood Pressure Measurement with the Validation Protocols of the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI). Arquivos Brasileiros de Cardiologia 2003;79(6):606-10.

Electronic Document Format (ABNT)

Mano, Gisele M. P.; Souza, Viviane F.; Pierin, Angela M. G.; Lima, Josiane C.; Ignes, Edna C.; Ortega, Kátia C.; Mion Jr., Décio. Assessment of the DIXTAL DX-2710 Automated Oscillometric Device for Blood Pressure Measurement with the Validation Protocols of the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI). Arquivos Brasileiros de Cardiologia, v. 79, n. 6, p. 606-610, Jan. 2003.

Electronic Document Format (APA)

Mano, G. M. P., Souza, V. F., Pierin, A. M. G., Lima, J. C., Ignes, E. C., Ortega, K. C., & Mion Jr., D. (2003). Assessment of the DIXTAL DX-2710 Automated Oscillometric Device for Blood Pressure Measurement with the Validation Protocols of the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI). Arquivos Brasileiros de Cardiologia, 79(6), 606-610.

Electronic Document Format (ISO)

Mano, Gisele M. P. and Souza, Viviane F. and Pierin, Angela M. G. and Lima, Josiane C. and Ignes, Edna C. and Ortega, Kátia C. and Mion Jr., Décio. Assessment of the DIXTAL DX-2710 Automated Oscillometric Device for Blood Pressure Measurement with the Validation Protocols of the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI). Arquivos Brasileiros de Cardiologia [online]. 2003, vol. 79, n. 6, [cited 2026-10-14], pp. 606-610. Available from: <https://journals.cardiol.br/en/article/assessment-of-the-dixtal-dx-2710-automated-oscillometric-device-for-blood-pressure-measurement-with-the-validation-protocols-of-the-british-hypertension-society-bhs-and-the-association-for-the-advan/>. ISSN 0066-782X

  • About ABC Family
  • Internal Regulation
  • Editorial Board
  • Brazilian Society of Cardiology (SBC)

Issues

SBC Guidelines

  • Videos
  • Podcasts
  • News