<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.1" specific-use="sps-1.9" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">dic</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia Imagem cardiovascular</journal-title>
        
        <abbrev-journal-title abbrev-type="publisher">Arq Bras Cardiol: Imagem cardiovasc</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="epub">2675-312X</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia</publisher-name>
        
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">2318-8219.20170019</article-id>
      <article-id pub-id-type="doi">10.5935/2318-8219.20170019</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Comparison of Block-Matching and Optical Flow in Strain Echocardiography Analysis</article-title>
        <trans-title-group xml:lang="es">
          <trans-title>Comparación entre Técnicas de Block-Matching y Optical Flow en el análisis del Strain por Ecocardiografía</trans-title>
        </trans-title-group>
        <trans-title-group xml:lang="pt">
          <trans-title>Comparação entre Técnicas de Block-Matching e Optical Flow na análise do Strain pela Ecocardiografia</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group><contrib contrib-type="author"><name><surname>Linhares</surname><given-names>Renata Rejane</given-names></name><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name><surname>Barreto</surname><given-names>Rodrigo Bellio de Mattos</given-names></name><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name><surname>Silva</surname><given-names>Carlos Eduardo Suaide</given-names></name><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name><surname>Le Bihan</surname><given-names>David Costa de Souza</given-names></name><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name><surname>Peixoto</surname><given-names>Luciana Braz</given-names></name><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name><surname>Cruz</surname><given-names>Andresa Paes da</given-names></name><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name><surname>Garcia</surname><given-names>Luara Piovan</given-names></name><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name><surname>Monaco</surname><given-names>Claudia Gianini</given-names></name><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name><surname>Gil</surname><given-names>Manuel Adán</given-names></name><xref ref-type="aff" rid="aff1"/></contrib></contrib-group>
      <aff id="aff1"><institution content-type="orgname">DASA</institution><addr-line><named-content content-type="city">São Paulo</named-content><named-content content-type="state">SP</named-content></addr-line><country country="BR">Brazil</country><institution content-type="original">DASA - Diagnóstico das Américas SA, São Paulo, SP – Brazil</institution></aff>
      <author-notes> <corresp id="c01"> <bold>Mailing Address: Renata Rejane Linhares •</bold> Rua Vergueiro, nº 7165, apto 173. Postal Code 04273-100, Vila Firmiano Pinto, São Paulo, SP - Brazil E-mail: <email>relinhares1977@gmail.com</email> </corresp> <fn fn-type="con"> <p>Authors’ contributions</p> <p>Research creation and design: Linhares RR, Silva CES, Monaco CG, Gil MA; Data acquisition: Linhares RR, Silva CES, Monaco CG, Gil MA; Analysis and interpretation of data: Linhares RR, Barreto RBM, Silva CES, Peixoto LB, Cruz AP, Monaco CG, Gil MA; Statistical analysis: Linhares RR, Barreto RBM, Silva CES, Le Bihan DCS, Peixoto LB, Cruz AP, Garcia LP; Manuscript drafting: Linhares RR, Barreto RBM, Silva CES, Le Bihan DCS, Peixoto LB, Cruz AP, Garcia LP; Critical revision of the manuscript as for important intellectual content: Linhares RR, Barreto RBM, Silva CES, Le Bihan DCS, Peixoto LB, Cruz AP, Garcia LP.</p> </fn><fn fn-type="conflict"><p>Potential Conflicts of Interest</p> <p>There are no relevant conflicts of interest.</p></fn> </author-notes>
      <pub-date date-type="pub" publication-format="electronic">
				<day>04</day>
				<month>02</month>
				<year>2022</year>
			</pub-date>
			<pub-date date-type="collection" publication-format="electronic">
        <season>Jul-Sept</season>
        <year>2017</year>
      </pub-date>
      <volume>30</volume>
      <issue>3</issue>
      <fpage>87</fpage>
      <lpage>91</lpage>
      <history><date date-type="accepted"><day>7</day><month>10</month><year>2016</year></date><date date-type="rev-recd"><day>25</day><month>12</month><year>2016</year></date><date date-type="accepted"><day>6</day><month>02</month><year>2017</year></date></history>
          <permissions>
      <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
        <license-p> This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. </license-p>
      </license>
    </permissions>
      <abstract><title>Abstract</title><sec><title>Introduction</title><p> Different technologies have been used to evaluate left ventricular systolic function. Of particular interest is the two-dimensional strain echocardiography (2DSTE). Two different methods have been used to quantify myocardial strain by 2DSTE: block matching and optical flow. Both are present in commercially available echocardiographs. However, there is no consensus as to whether the longitudinal strain measures using these methods are overlapping.</p></sec><sec><title>Objective</title><p> To compare the longitudinal myocardial strain peak values obtained through 2DSTE using two different methods (block matching x optical flow).</p></sec><sec><title>Method</title><p> Strain measurements in 16 left ventricular myocardial segments were taken as recommended by the American Society of Echocardiography using block matching (Vivid 7, GE, Horten, Norway) and, immediately after, using optical flow (My Lab 60, Esaote, Florence, Italy) in a randomized way and their values were compared.</p></sec><sec><title>Results</title><p> There were 28 individuals aged 27.9 ± 7.7, of whom 50% were male and all with an ejection fraction greater than 55%. Global longitudinal strain was higher using block matching (p = 0.02). In the analysis of the 16 segments, 10 segments had different values, especially the apical segments.</p></sec><sec><title>Conclusion</title><p> Longitudinal myocardial strain values obtained by different methods are not overlapping and must be used with caution. Normality values also vary according to the manufacturer and the method used. (Arq Bras Cardiol: Imagem cardiovasc. 2017;30(3):87-91)</p></sec></abstract>
      <trans-abstract xml:lang="es"><title>Resumen</title><sec><title>Introducción</title><p> Diferentes tecnologías han sido utilizadas para evaluar la función sistólica del ventrículo izquierdo.De particular interés, está la ecocardiografía con strain bidimensional (2DSTE). Dos métodos diferentes han sido usados para cuantificar la deformación miocárdica (strain miocárdico) por la 2DSTE: block matching y optical flow.Ambos están presentes en ecocardiógrafos comercialmente disponibles. Entre tanto, no hay consenso respecto a si las medidas del strain longitudinal por estos métodos son superponibles.Objetivo: Comparar los valores de pico del strain miocárdico longitudinal obtenidos por medio de la 2DSTE por los dos diferentes métodos (block matching x optical flow).</p></sec><sec><title>Método</title><p> Fueron realizadas las medidas del strain en 16 segmentos miocárdicos del ventrículo izquierdo, según orientación de la Sociedad Americana de Ecocardiografía por la técnica del block matching (Vivid 7, GE, Horten, Noruega) e, inmediatamente después, por la técnica del optical flow (My Lab 60, Esaote, Florença, Itália) de forma randomizada y sus valores fueron comparados.</p></sec><sec><title>Resultados</title><p> Hubo 28 individuos con edad 27,9 ± 7,7 años, siendo 50% del sexo masculino y todos con fracción de eyección superior a 55%. La medida del strain longitudinal global fue mayor por la técnica de block matching (p = 0,02). En el análisis de los 16 segmentos, hubo 10 segmentos con valores diferentes, en especial los segmentos apicales.</p></sec><sec><title>Conclusión</title><p> Los valores del strain miocárdico longitudinal obtenidos por métodos diferentes no son superponibles y deben ser usados con cautela. Siendo así, valores de normalidad también varían de acuerdo con el fabricante y el método utilizado. (Arq Bras Cardiol: Imagem cardiovasc. 2017;30(3):87-91)</p></sec></trans-abstract>
      <trans-abstract xml:lang="pt"><title>Resumo</title><sec><title>Introdução</title><p> Diferentes tecnologias têm sido utilizadas para avaliar a função sistólica do ventrículo esquerdo.De particular interesse, está a ecocardiografia com strain bidimensional (2DSTE). Dois métodos diferentes têm sido usados para quantificar a deformação miocárdica (strain miocárdico) pela 2DSTE: block matching e optical flow. Ambos estão presentes em ecocardiógrafos comercialmente disponíveis. Entretanto, não há consenso a respeito se as medidas do strain longitudinal por estes métodos são sobreponíveis.</p></sec><sec><title>Objetivo</title><p> Comparar os valores de pico do strain miocárdico longitudinal obtidos através da 2DSTE pelos dois diferentes métodos (block matching x optical flow).</p></sec><sec><title>Método</title><p> Foram realizadas as medidas do strain em 16 segmentos miocárdicos do ventrículo esquerdo, conforme orientação da Sociedade Americana de Ecocardiografia pela técnica do block matching (Vivid 7, GE, Horten, Noruega) e, imediatamente após, pela técnica do optical flow (My Lab 60, Esaote, Florença, Itália) de forma randomizada e seus valores foram comparados.</p></sec><sec><title>Resultados</title><p> Houve 28 indivíduos com idade 27,9 ± 7,7 anos, sendo 50% do sexo masculino e todos com fração de ejeção superior a 55%. A medida do strain longitudinal global foi maior pela técnica de block matching (p = 0,02). Na análise dos 16 segmentos, houve 10 segmentos com valores diferentes, em especial os segmentos apicais.</p></sec><sec><title>Conclusão</title><p> Os valores do strain miocárdico longitudinal obtidos por métodos diferentes não são sobreponíveis e devem ser usados com cautela. Sendo assim, valores de normalidade também variam de acordo com o fabricante e o método utilizado. (Arq Bras Cardiol: Imagem cardiovasc. 2017;30(3):87-91)</p></sec></trans-abstract>
      <kwd-group xml:lang="en"><kwd>Echocardiography, Doppler/methods</kwd><kwd>Heart Diseases</kwd><kwd>Diagnostic Imaging</kwd><kwd>Image Processing Computer-Assisted/methods</kwd></kwd-group>
      <kwd-group xml:lang="es"><kwd>Ecocardiografía Doppler/métodos</kwd><kwd>Cardiopatías</kwd><kwd>Diagnóstico por Imagen</kwd><kwd>Processamento de Imagen assistida por Computador /métodos</kwd></kwd-group>
      <kwd-group xml:lang="pt"><kwd>Ecocardiografia Doppler/métodos</kwd><kwd>Cardiopatias</kwd><kwd>Diagnóstico por Imagem</kwd><kwd>Processamento de Imagem assistida por Computador /métodos</kwd></kwd-group>
      <counts><fig-count count="0"/><table-count count="0"/><equation-count count="0"/><ref-count count="0"/><page-count count="5"/></counts>
    </article-meta>
  </front>
  <body/>
  <back/>
</article>
