﻿<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article article-type="review-article" dtd-version="1.1" specific-use="sps-1.9" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
	<front>
		<journal-meta>
			<journal-id journal-id-type="publisher-id">abcimg</journal-id>
			<journal-title-group>
				<journal-title>ABC Imagem Cardiovascular</journal-title>
				<abbrev-journal-title abbrev-type="publisher">Arq Bras Cardiol: Imagem cardiovasc.</abbrev-journal-title>
			</journal-title-group>
			<issn pub-type="epub">2675-312X</issn>
			<publisher>
				<publisher-name>Sociedade Brasileira de Cardiologia</publisher-name>
			</publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="publisher-id">abcimg.20240034i</article-id>
			<article-id pub-id-type="doi">10.36660/abcimg.20240034i</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Review Article</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>My Approach to Assessment of Mitral Paraprosthetic Leak</article-title>
			</title-group>
			<contrib-group>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0002-3543-754X</contrib-id>
					<name>
						<surname>Bignoto</surname>
						<given-names>Tiago</given-names>
					</name>
					<role>Conception and design of the research</role>
					<role>acquisition of data</role>
					<role>analysis and interpretation of the data</role>
					<role>statistical analysis</role>
					<role>obtaining financing</role>
					<role>writing of the manuscript and critical revision of the manuscript for intellectual content</role>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
					<xref ref-type="corresp" rid="c1"/>
				</contrib>
				<aff id="aff1">
					<label>1</label>
					<institution content-type="orgname">Universidade de São Paulo</institution>
					<addr-line>
						<named-content content-type="city">São Paulo</named-content>
						<named-content content-type="state">SP</named-content>
					</addr-line>
					<country country="BR">Brazil</country>
					<institution content-type="original">Universidade de São Paulo, Cardiopatia Estrutural, São Paulo, SP – Brazil</institution>
				</aff>
			</contrib-group>
			<author-notes>
				<corresp id="c1"><bold>Mailing Address: Tiago Bignoto</bold> • Universidade de São Paulo, Cardiopatia Estrutural. Avenida Dr. Enéas Carvalho de Aguiar, 44. Postal code: <postal-code>05403-900</postal-code>. São Paulo, SP – Brazil E-mail: <email>tiagobignoto@yahoo.com.br</email>
				</corresp>
				<fn fn-type="edited-by">
					<p>Editor responsible for the review: Marcelo Tavares</p>
				</fn>
				<fn fn-type="conflict">
					<p><bold>Potential Conflict of Interest</bold></p>
					<p>No potential conflict of interest relevant to this article was reported.</p>
				</fn>
			</author-notes>
			<pub-date date-type="pub" publication-format="electronic">
				<day>06</day>
				<month>06</month>
				<year>2024</year>
			</pub-date>
			<pub-date date-type="collection" publication-format="electronic">
				<month>06</month>
				<year>2024</year>
			</pub-date>
			<volume>37</volume>
			<issue>2</issue>
			<elocation-id>e20240034</elocation-id>
			<history>
				<date date-type="received">
					<day>24</day>
					<month>04</month>
					<year>2024</year>
				</date>
				<date date-type="rev-recd">
					<day>06</day>
					<month>05</month>
					<year>2024</year>
				</date>
				<date date-type="accepted">
					<day>06</day>
					<month>05</month>
					<year>2024</year>
				</date>
			</history>
			<permissions>
				<license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/" xml:lang="en">
					<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution License</license-p>
				</license>
			</permissions>
			<abstract>
				<title>Abstract</title>
				<p>Mitral paraprosthetic leak is a common, often asymptomatic condition. When presented with clinical manifestations such as heart failure and/or hemolysis, interventional treatment is indicated. The transcatheter approach has become increasingly popular, requiring careful planning using imaging methods, particularly echocardiography. Echocardiography is crucial for assessing the severity, location, size, shape, and number of leaks. Once these variables are determined, the treatment approach is planned, typically using the transseptal route. The optimal puncture site depends on various factors, with precise puncture location being paramount. Intraoperative echocardiographic evaluation is essential for procedure success, guiding device positioning and adjustments while also identifying any potential complications.</p>
			</abstract>
			<kwd-group xml:lang="en">
				<title>Keywords</title>
				<kwd>Mitral Valve</kwd>
				<kwd>Heart Valve Prosthesis</kwd>
				<kwd>Heart Valve Diseases</kwd>
			</kwd-group>
			<counts>
				<fig-count count="6"/>
				<table-count count="2"/>
				<equation-count count="0"/>
				<ref-count count="17"/>
			</counts>
		</article-meta>
	</front>
	<body>
		<sec sec-type="intro">
			<title>Introduction</title>
			<p>Paraprosthetic Leak occurs when a reflux appears around a valve prosthesis and can have several causes.<sup><xref ref-type="bibr" rid="B1">1</xref>–<xref ref-type="bibr" rid="B4">4</xref></sup> Most often, these are incidental findings, having clinical repercussions in only 5% of individuals. Related clinical manifestations include complaints such as heart failure in 85% of cases and/or clinically significant hemolysis in up to 47%.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
			<p>With a prevalence of up to 17%, the mechanism is diverse and sometimes poorly understood. A gap between the suture ring and the native valve ring may occur due to excessive calcification, an infectious event, or technical issues during surgery.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B3">3</xref></sup> In mitral valve topography, this finding is seen in up to 15% of patients undergoing mitral valve replacement.<sup><xref ref-type="bibr" rid="B5">5</xref></sup></p>
			<p>According to recent guidelines,<sup><xref ref-type="bibr" rid="B2">2</xref>–<xref ref-type="bibr" rid="B4">4</xref></sup> leak repair is recommended for patients experiencing clinical heart failure or significant hemolysis.</p>
			<p>Due to the risks associated with new surgical approaches, transcatheter treatment has become more prevalent in specialized centers for cases with favorable anatomies. However, complications such as interference with the prosthesis or nearby structures can occur.</p>
			<p>Urgent surgery or death can occur in up to 4% of cases. In contrast, the composite outcome of adverse events within 30 days, including death, myocardial infarction, stroke, major bleeding, and emergency surgery, can reach up to 8.7%.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref></sup></p>
			<p>The technical success rate of percutaneous closure was reported to be 86%, with an improvement in the functional class of up to 77%.<sup><xref ref-type="bibr" rid="B6">6</xref></sup> Ruiz et al.<sup><xref ref-type="bibr" rid="B7">7</xref></sup> reported long-term survival at 6, 12, and 18 months as 91.9, 89.2, and 86.5%, respectively. Sorajja et al.<sup><xref ref-type="bibr" rid="B8">8</xref></sup> found a survival rate of 75% for 1 to 2 years after percutaneous paraprosthetic leak closure and an estimated 3-year survival rate of 64.5%.</p>
			<p>In screening by the Heart Team, relevant aspects of diagnostic imaging are fundamental for the therapeutic decision. A comprehensive investigation is mandatory, including transthoracic echocardiography with the identification and classification of the degree of reflux, as well as transesophageal complementation using three-dimensional (3D) imaging.<sup><xref ref-type="bibr" rid="B4">4</xref>.<xref ref-type="bibr" rid="B6">6</xref></sup></p>
			<p>Before planning a possible approach, local or systemic infectious conditions, as well as the presence of cavitary thrombi, must be excluded.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B9">9</xref></sup></p>
			<sec>
				<title>Leak Image Assessment</title>
				<p>Patient eligibility and scheduling for potential closure begins with obtaining high-quality images. Various methods are available to diagnose paraprosthetic leaks, including transthoracic echocardiogram (TTE), transesophageal echocardiogram (TEE), computed tomography (CT), and magnetic resonance imaging (MRI). Among these, there is no ideal diagnostic method, although echocardiographic imaging is the most commonly used and widely available method.</p>
				<p>As an advantage, echocardiography allows for a direct comparison of pre-procedural images with intra-procedural results. However, echocardiography is susceptible to specific artifacts from acoustic shadows, which can complicate assessment. 3D complementation improves spatial definition, adding the ability to determine the path of a leak, which can often follow a serpentine-like course.<sup><xref ref-type="bibr" rid="B10">10</xref></sup></p>
				<p>On a superficial level, the first information to be checked and confirmed is the severity, location, size, shape, and number of leaks. Initially, the valve prosthesis is &quot;scanned&quot; through a systematic rotation of the echo probe, searching for the presence of dehiscence and/or paraprosthetic signs with the color Doppler.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B4">4</xref>,<xref ref-type="bibr" rid="B6">6</xref></sup></p>
				<p>The type of prosthesis and the techniques employed for its implantation are fundamental during the imaging evaluation. The team must be aware of various factors, from the technique used for suturing to potential prosthetic materials like patches that aid in fixation.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
				<p>Evaluating a paraprosthetic leak requires consideration of multiple parameters and the patient's anatomical structure. The first step is assessing the movement of the device relative to the native ring. Displacements of the device, known as &quot;Rock Motion,&quot; indicate significant dehiscences affecting more than 40% of the ring. In some cases, this hypermobility may result from adjacent tissue mobility due to infectious events. In such cases, a transcatheter approach is contraindicated, and prompt evaluation for conventional surgery is necessary (<xref ref-type="fig" rid="f2">Video 1</xref>).<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
				<fig id="f2">
					<label>Video 1</label>
					<caption>
						<title>Transthoracic echocardiography image, an apical 4-chamber window showing rock motion image of the mitral valve prosthesis. Link: <ext-link ext-link-type="uri" xlink:href="http://abcimaging.org/supplementary-material/2024/3703/2024-0034_vïdeo_01.mp4">http://abcimaging.org/supplementary-material/2024/3703/2024-0034_vïdeo_01.mp4</ext-link>
						</title>
					</caption>
					<media id="mf2" mime-subtype="mp4" mimetype="video" xlink:href="2675-312X-abcimg-37-02-e20240034-m01.mp4"/>
				</fig>
				<p>Once this complication has been ruled out, the Doppler parameters need to be evaluated, as in <xref ref-type="table" rid="t1">Table 1</xref>.</p>
				<table-wrap id="t1">
					<label>Table 1</label>
					<caption>
						<title>Echocardiographic Parameters to Evaluate Mitral Paraprosthetic Leak</title>
					</caption>
					<table frame="hsides" rules="groups">
						<colgroup width="14%">
							<col/>
							<col/>
							<col/>
							<col/>
							<col/>
							<col/>
							<col/>
						</colgroup>
						<thead style="border-top: thin solid; border-bottom: thin solid; border-color: #000000">
							<tr style="background-color:#C58874">
								<th align="left" valign="middle"/>
								<th align="center" valign="middle">Feature</th>
								<th align="center" valign="middle">Minor</th>
								<th align="center" valign="middle">Minor to Moderate</th>
								<th align="center" valign="middle">Moderate</th>
								<th align="center" valign="middle">Moderate to Major</th>
								<th align="center" valign="middle">Major</th>
							</tr>
						</thead>
						<tbody style="border-bottom: thin solid; border-color: #000000">
							<tr>
								<td align="left" valign="middle">VC, mm</td>
								<td align="center" valign="middle">Minimum</td>
								<td align="center" valign="middle">&lt;2</td>
								<td align="center" valign="middle">2-3</td>
								<td align="center" valign="middle">3-5</td>
								<td align="center" valign="middle">5-7</td>
								<td align="center" valign="middle">≥7</td>
							</tr>
							<tr style="background-color:#E8CCBF">
								<td align="left" valign="middle">Circumference, %</td>
								<td align="center" valign="middle">Minimum</td>
								<td align="center" valign="middle">&lt;5</td>
								<td align="center" valign="middle">5-10</td>
								<td align="center" valign="middle">10-20</td>
								<td align="center" valign="middle">20-30</td>
								<td align="center" valign="middle">≥30</td>
							</tr>
							<tr>
								<td align="left" valign="middle">Reg. Vol., mL</td>
								<td align="center" valign="middle">&lt;10</td>
								<td align="center" valign="middle">&lt;15</td>
								<td align="center" valign="middle">15-30</td>
								<td align="center" valign="middle">30-45</td>
								<td align="center" valign="middle">45-60</td>
								<td align="center" valign="middle">≥60</td>
							</tr>
							<tr style="background-color:#E8CCBF">
								<td align="left" valign="middle">RF, %</td>
								<td align="center" valign="middle">&lt;15</td>
								<td align="center" valign="middle">&lt;15</td>
								<td align="center" valign="middle">15-30</td>
								<td align="center" valign="middle">30-40</td>
								<td align="center" valign="middle">40-50</td>
								<td align="center" valign="middle">≥50</td>
							</tr>
							<tr>
								<td align="left" valign="middle">ERO, mm<sup>2</sup></td>
								<td align="center" valign="middle">&lt;5</td>
								<td align="center" valign="middle">&lt;5</td>
								<td align="center" valign="middle">5-20</td>
								<td align="center" valign="middle">20-30</td>
								<td align="center" valign="middle">30-40</td>
								<td align="center" valign="middle">≥40</td>
							</tr>
						</tbody>
					</table>
					<table-wrap-foot>
						<fn id="TFN1">
							<p>VC: Vena Contracta; Reg. Vol.: Regurgitant volume; RF: Regurgitant fraction; ERO: Effective Reflux Orifice.</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
				<p>The first step is to grade the intensity of the regurgitation, as well as its hemodynamic repercussions. Parameters commonly used in the echocardiographic classification of native valve lesions can be extrapolated with caution to the assessment of paraprosthetic leaks.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
				<p>Assessments of Doppler curves of the pulmonary veins in mitral topography leaks and that of the ascending aorta in aortic topography seem useful at first. The observation of high transprosthetic gradients, even with normal aspects of the leaflets or mobile elements, also signals the possibility of hyperflow and important paraprosthetic leak.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
				<p>Signs of progressive eccentric hypertrophy also make up the diagnosis of regurgitation severity, signaling significant volume overload.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
			</sec>
			<sec>
				<title>Location</title>
				<p>Location and findings in echocardiographic reports typically adhere to a standardized pattern. The topography of the device is often described using a clock reference, mirroring the surgeon's view in the operating room as depicted in the <xref ref-type="fig" rid="f1">Central Illustration</xref>.<sup><xref ref-type="bibr" rid="B10">10</xref></sup></p>
				<fig id="f1">
					<caption>
						<title>Schematic drawing of the paraprosthetic leak location and orientation in a mitral prosthesis.</title>
					</caption>
					<graphic xlink:href="2675-312X-abcimg-37-02-e20240034-gf02.tif"/>
				</fig>
				<p>In the case of the mitral position, guidance can be based on both clock-face orientation and anatomical relationships. The location is determined relative to the mitral valve annulus and is described as medial, lateral, anterior, or posterior. The clock begins at the 12 o'clock position, toward the aortic valve, which makes the 3 o'clock position at the posteromedial commissure or toward the interatrial septum, and the 6 o'clock position at the midpoint of the posterior ring. This detailed location of the puncture facilitates the optimal selection of the transseptal puncture site.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref></sup></p>
			</sec>
			<sec>
				<title>Dimensions</title>
				<p>Although the course of the leak may be serpentine-like, assessment of the reflux vena contracta is an important step towards its classification and planning of a possible transcatheter approach, including the selection of devices to be used.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
				<p>There is no recommendation to cross the leak with balloon catheters to measure its size due to the risk of iatrogenic injuries in this procedure.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
				<p>To accurately determine the size of the leak, both grayscale images with acquisition data and color flow are utilized. Using dedicated software, a cutting plane parallel to the ring is positioned at the leak level, enabling derivation of the maximum and minimum diameter and area (see <xref ref-type="fig" rid="f3">Figure 1</xref>).<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
				<fig id="f3">
					<label>Figure 1</label>
					<caption>
						<title>Assessment of size and appearance of the mitral paraprosthetic leak. A) Steps for calculating the area of the vena contracta and its dimensions. B) Use of the 3D method to measure the dimensions of the paraprosthetic leak. C and D) Assessment on different color scales and with Color Doppler. Adapted from Gafoor et al.<sup><xref ref-type="bibr" rid="B1">1</xref></sup> and Pysz et al.<sup><xref ref-type="bibr" rid="B6">6</xref></sup></title>
					</caption>
					<graphic xlink:href="2675-312X-abcimg-37-02-e20240034-gf01.tif"/>
				</fig>
				<p>A method to enhance the assessment of leak dimensions post-localization is to obtain an image with the smallest possible volume containing the complete path of the leak, achieved through single-beat Gated electrocardiograph (ECG) and a high 3D volume rate (HVR). Subsequently, the Color Doppler mode is acquired. The leak is then opacified by the mapped flow of turbulence seen by Color Doppler in multiplanar analysis. It allows the visualization of the shape of the leak's vena contracta and measurement of its dimensions.<sup><xref ref-type="bibr" rid="B6">6</xref></sup></p>
				<p>Recently, new 3D image rendering techniques have been introduced to facilitate detailed visualization of the morphology of the leak's path, aiding in the precise guidance of interventional procedures.</p>
			</sec>
			<sec>
				<title>Planning and Intraoperative Steps</title>
				<p>The first step is to define the access route to approach the leak. Venous or arterial access alternatives are possible in any condition but must be selected according to certain anatomical variations. Femoral venous access requires a transseptal puncture to access the left side, and this procedure is important in planning how to manage catheters inside the left atrium.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref></sup></p>
				<p>A short-axis view of the aortic valve is acquired, positioned between 20 and 50 degrees, with a focus on the interatrial septum. This is followed by activating the multiplanar mode to display an orthogonal image corresponding to the bicaval view.<sup><xref ref-type="bibr" rid="B11">11</xref></sup></p>
				<p>For mitral leaks, selecting the transseptal puncture site should consider its location to enhance the procedure's success rate. Typically, a central puncture is preferred, allowing sufficient height above the mitral annulus to accommodate the curvature of the steerable sheath (usually around 2.5 cm, depending on the model and sheath size).<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B9">9</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
				<p>The anterograde crossing of the leak opening is conceptually carried out using a transseptal approach, with closure performed retrogradely by pulling the device from the left ventricle toward the left atrium.<sup><xref ref-type="bibr" rid="B11">11</xref></sup></p>
				<p>For mitral leaks in the anterior region, a more superior puncture may be better as it generally improves coaxiality during traversal. The posteriorly located mitral leak remains the most challenging to access. A low posterior puncture is generally necessary to obtain the best coaxiality, allowing crossover. However, this can be constrained by individual anatomical variations, such as the size of the fossa ovalis and the angle at which the inferior vena cava enters the right atrium.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B9">9</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
				<p>In cases where the anatomy of the mitral access is challenging, retrograde transfemoral arterial access can be considered due to its anatomical feasibility in approaching the leak.<sup><xref ref-type="bibr" rid="B6">6</xref></sup> The transapical thoracotomy approach may also be used to aid in anatomical positioning, but this is typically an exceptional measure.<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
				<p>A hydrophilic wire is generally used to cross the leak, followed by the insertion of a diagnostic catheter. Subsequently, the wire is exchanged for a stiffer one, guided by fluoroscopy and intraoperative transesophageal echocardiography.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
				<p>Intraoperative echocardiography plays a crucial role in the procedure, supporting tasks ranging from transseptal puncture to crossing the leak with wires and catheters, as well as in the precise positioning of occlusion devices. It is also essential for the early detection of serious complications such as tamponade or the risk of wire entanglement within the cardiac chambers.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B9">9</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
				<p>In instances where the orifice is narrow or anatomically distorted, positioning and crossing can be particularly challenging. In these situations, after the catheter tip is positioned near the leak orifice, as confirmed by transesophageal 3D echocardiography, it may be beneficial to revert to biplanar color Doppler imaging. This approach enables precise guidance of catheter and/or wire movements toward the orifice, allowing simultaneous visualization in two directions with superior temporal and spatial resolution compared to 3D imaging.<sup><xref ref-type="bibr" rid="B6">6</xref></sup></p>
				<p>In selected cases, to mitigate the risks associated with transesophageal echocardiography and anesthesia, intracardiac echocardiography may serve as an alternative, despite its technical limitations compared to transesophageal echocardiography devices, particularly in terms of spatial definition, and its limited availability in most national services.<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B10">10</xref>,<xref ref-type="bibr" rid="B12">12</xref>,<xref ref-type="bibr" rid="B13">13</xref></sup></p>
				<p>When choosing closing devices, it is recommended to select those 2 to 3 mm larger than the measured diameter. After positioning and fully opening the devices inside the orifice but while still attached to the introducers, echocardiography should be used to evaluate the immediate results. This should include an assessment of the mobility of the prosthesis located there, residual regurgitation jet with assessment of vena contracta and effective regurgitation area (ROS), as well as hemodynamic parameters evaluated by Doppler, such as transprosthetic gradients and flow in pulmonary veins, among others.<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
				<p>Due to the limited availability of devices designed for occluding paraprosthetic leaks, adaptations are often necessary during the planning of this intervention. Consequently, finding a perfect device is uncommon. Still, it is crucial to consider potential interference with prosthetic leaflets or other mobile elements, as well as adjacent anatomical structures like the left ventricular outflow tract.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
				<p>Operators should also note any changes in hemodynamic conditions during intra-procedural evaluations and compare them with pre-procedure conditions, especially considering the effects of anesthesia or deep sedation.<sup><xref ref-type="bibr" rid="B6">6</xref></sup></p>
				<p>While mild residual regurgitation may not have significant hemodynamic repercussions, any residual injury should not be tolerated due to the risk of developing clinically significant hemolysis post-procedure, which would not benefit the patient. In cases of moderate or severe injuries, repositioning of occluding devices, addition of more devices, or selection of devices with different shapes may be necessary.<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B14">14</xref></sup></p>
				<p>Echocardiographic and laboratory monitoring to evaluate residual regurgitation or hemolysis should be performed at least every six months or in cases of changes in the patient's symptoms. Although rare, device displacements can occur, leading to some degree of regurgitation or hemolysis over the years.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
			</sec>
			<sec>
				<title>New Imaging Methods and Special Situations</title>
				<p>In some cases, new techniques and tools may be used to improve visualization and spatial definition. Transillumination (Philips®), a new 3D rendering tool that uses a moving light source to improve depth perception, can be used to localize the paraprosthetic leak better.<sup><xref ref-type="bibr" rid="B15">15</xref></sup> Another promising tool is the fusion image between echocardiography and fluoroscopy. In cases of acoustic shadows secondary to prostheses that pose a significant limitation to transesophageal echocardiography, the use of EchoNavigator software, already employed in transcatheter procedures for other valve pathologies, can be a useful tool to guide the interventional team.<sup><xref ref-type="bibr" rid="B16">16</xref></sup></p>
				<p>The production of 3D printed models for adequate intervention planning and also for training centers has emerged as an interesting technique. The first step is to acquire high-quality image data in a DICOM (Digital Imaging and Communication in Medicine) format, whether by echocardiography, tomography, or another method. This data is processed and exported into stereolithography file formats, which are then used by the 3D printer.<sup><xref ref-type="bibr" rid="B17">17</xref></sup></p>
			</sec>
			<sec sec-type="conclusions">
				<title>Final Considerations</title>
				<p>The use of imaging techniques is crucial in both the screening and intra-procedural stages of percutaneous closure of paravalvular mitral leaks. It has a significant impact on prognosis. A thorough discussions within a Heart Team setting is a decisive step, and the echocardiographers play a pivotal role in this process.</p>
			</sec>
		</sec>
	</body>
	<back>
		<fn-group>
			<fn fn-type="financial-disclosure">
				<p><bold>Sources of Funding</bold></p>
				<p>There were no external funding sources for this study.</p>
			</fn>
			<fn fn-type="other" id="fn2">
				<p><bold>Study Association</bold></p>
				<p>This study is not associated with any thesis or dissertation work.</p>
			</fn>
			<fn fn-type="other" id="fn3">
				<p><bold>Ethics Approval and Consent to Participate</bold></p>
				<p>This article does not contain any studies with human participants or animals performed by any of the authors.</p>
			</fn>
		</fn-group>
		<ref-list>
			<title>References</title>
			<ref id="B1">
				<label>1</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Gafoor</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Franke</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Bertog</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Lam</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Vaskelyte</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>Hofmann</surname>
							<given-names>I</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>A Quick Guide to Paravalvular Leak Closure</article-title>
					<source>Interv Cardiol</source>
					<year>2015</year>
					<volume>10</volume>
					<issue>2</issue>
					<fpage>112</fpage>
					<lpage>117</lpage>
					<pub-id pub-id-type="doi">10.15420/ICR.2015.10.2.112</pub-id>
				</element-citation>
				<mixed-citation>1 Gafoor S, Franke J, Bertog S, Lam S, Vaskelyte L, Hofmann I, et al. A Quick Guide to Paravalvular Leak Closure. Interv Cardiol. 2015;10(2):112-7. doi: 10.15420/ICR.2015.10.2.112.</mixed-citation>
			</ref>
			<ref id="B2">
				<label>2</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Otto</surname>
							<given-names>CM</given-names>
						</name>
						<name>
							<surname>Nishimura</surname>
							<given-names>RA</given-names>
						</name>
						<name>
							<surname>Bonow</surname>
							<given-names>RO</given-names>
						</name>
						<name>
							<surname>Carabello</surname>
							<given-names>BA</given-names>
						</name>
						<name>
							<surname>Erwin</surname>
							<given-names>JP</given-names>
							<suffix>3rd</suffix>
						</name>
						<name>
							<surname>Gentile</surname>
							<given-names>F</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease: Executive Summary: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines</article-title>
					<source>Circulation</source>
					<year>2021</year>
					<volume>143</volume>
					<issue>5</issue>
					<fpage>35</fpage>
					<lpage>71</lpage>
					<pub-id pub-id-type="doi">10.1161/CIR.0000000000000932</pub-id>
				</element-citation>
				<mixed-citation>2 Otto CM, Nishimura RA, Bonow RO, Carabello BA, Erwin JP 3rd, Gentile F, et al. 2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease: Executive Summary: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2021;143(5):35-71. doi: 10.1161/CIR.0000000000000932.</mixed-citation>
			</ref>
			<ref id="B3">
				<label>3</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Tarasoutchi</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>Montera</surname>
							<given-names>MW</given-names>
						</name>
						<name>
							<surname>Ramos</surname>
							<given-names>AIO</given-names>
						</name>
						<name>
							<surname>Sampaio</surname>
							<given-names>RO</given-names>
						</name>
						<name>
							<surname>Rosa</surname>
							<given-names>VEE</given-names>
						</name>
						<name>
							<surname>Accorsi</surname>
							<given-names>TAD</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Update of the Brazilian Guidelines for Valvular Heart Disease - 2020</article-title>
					<source>Arq Bras Cardiol</source>
					<year>2020</year>
					<volume>115</volume>
					<issue>4</issue>
					<fpage>720</fpage>
					<lpage>775</lpage>
					<pub-id pub-id-type="doi">10.36660/abc.20201047</pub-id>
				</element-citation>
				<mixed-citation>3 Tarasoutchi F, Montera MW, Ramos AIO, Sampaio RO, Rosa VEE, Accorsi TAD, et al. Update of the Brazilian Guidelines for Valvular Heart Disease - 2020. Arq Bras Cardiol. 2020;115(4):720-75. doi: 10.36660/abc.20201047.</mixed-citation>
			</ref>
			<ref id="B4">
				<label>4</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Vahanian</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Beyersdorf</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>Praz</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>Milojevic</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Baldus</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Bauersachs</surname>
							<given-names>J</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>2021 ESC/EACTS Guidelines for the Management of Valvular Heart Disease</article-title>
					<source>Eur Heart J</source>
					<year>2022</year>
					<volume>43</volume>
					<issue>7</issue>
					<fpage>561</fpage>
					<lpage>632</lpage>
					<pub-id pub-id-type="doi">10.1093/eurheartj/ehab395</pub-id>
				</element-citation>
				<mixed-citation>4 Vahanian A, Beyersdorf F, Praz F, Milojevic M, Baldus S, Bauersachs J, et al. 2021 ESC/EACTS Guidelines for the Management of Valvular Heart Disease. Eur Heart J. 2022;43(7):561-632. doi: 10.1093/eurheartj/ehab395.</mixed-citation>
			</ref>
			<ref id="B5">
				<label>5</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Janmohamed</surname>
							<given-names>IK</given-names>
						</name>
						<name>
							<surname>Mishra</surname>
							<given-names>V</given-names>
						</name>
						<name>
							<surname>Geragotellis</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Sherif</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Harky</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<article-title>Mitral Valve Paravalvular Leaks: Comprehensive Review of Literature</article-title>
					<source>J Card Surg</source>
					<year>2022</year>
					<volume>37</volume>
					<issue>2</issue>
					<fpage>418</fpage>
					<lpage>430</lpage>
					<pub-id pub-id-type="doi">10.1111/jocs.16145</pub-id>
				</element-citation>
				<mixed-citation>5 Janmohamed IK, Mishra V, Geragotellis A, Sherif M, Harky A. Mitral Valve Paravalvular Leaks: Comprehensive Review of Literature. J Card Surg. 2022;37(2):418-30. doi: 10.1111/jocs.16145.</mixed-citation>
			</ref>
			<ref id="B6">
				<label>6</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Pysz</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>Wojakowski</surname>
							<given-names>W</given-names>
						</name>
						<name>
							<surname>Smolka</surname>
							<given-names>G</given-names>
						</name>
					</person-group>
					<article-title>Paravalvular Leak Echo Imaging before and during the Percutaneous Procedure</article-title>
					<source>J Clin Med</source>
					<year>2022</year>
					<volume>11</volume>
					<issue>11</issue>
					<fpage>3155</fpage>
					<lpage>3155</lpage>
					<pub-id pub-id-type="doi">10.3390/jcm11113155</pub-id>
				</element-citation>
				<mixed-citation>6 Pysz P, Wojakowski W, Smolka G. Paravalvular Leak Echo Imaging before and during the Percutaneous Procedure. J Clin Med. 2022;11(11):3155. doi: 10.3390/jcm11113155.</mixed-citation>
			</ref>
			<ref id="B7">
				<label>7</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ruiz</surname>
							<given-names>CE</given-names>
						</name>
						<name>
							<surname>Jelnin</surname>
							<given-names>V</given-names>
						</name>
						<name>
							<surname>Kronzon</surname>
							<given-names>I</given-names>
						</name>
						<name>
							<surname>Dudiy</surname>
							<given-names>Y</given-names>
						</name>
						<name>
							<surname>Del Valle-Fernandez</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Einhorn</surname>
							<given-names>BN</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Clinical Outcomes in Patients Undergoing Percutaneous Closure of Periprosthetic Paravalvular Leaks</article-title>
					<source>J Am Coll Cardiol</source>
					<year>2011</year>
					<volume>58</volume>
					<issue>21</issue>
					<fpage>2210</fpage>
					<lpage>2217</lpage>
					<pub-id pub-id-type="doi">10.1016/j.jacc.2011.03.074</pub-id>
				</element-citation>
				<mixed-citation>7 Ruiz CE, Jelnin V, Kronzon I, Dudiy Y, Del Valle-Fernandez R, Einhorn BN, et al. Clinical Outcomes in Patients Undergoing Percutaneous Closure of Periprosthetic Paravalvular Leaks. J Am Coll Cardiol. 2011;58(21):2210-7. doi: 10.1016/j.jacc.2011.03.074.</mixed-citation>
			</ref>
			<ref id="B8">
				<label>8</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Sorajja</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>Cabalka</surname>
							<given-names>AK</given-names>
						</name>
						<name>
							<surname>Hagler</surname>
							<given-names>DJ</given-names>
						</name>
						<name>
							<surname>Rihal</surname>
							<given-names>CS</given-names>
						</name>
					</person-group>
					<article-title>Long-term Follow-up of Percutaneous Repair of Paravalvular Prosthetic Regurgitation</article-title>
					<source>J Am Coll Cardiol</source>
					<year>2011</year>
					<volume>58</volume>
					<issue>21</issue>
					<fpage>2218</fpage>
					<lpage>2224</lpage>
					<pub-id pub-id-type="doi">10.1016/j.jacc.2011.07.041</pub-id>
				</element-citation>
				<mixed-citation>8 Sorajja P, Cabalka AK, Hagler DJ, Rihal CS. Long-term Follow-up of Percutaneous Repair of Paravalvular Prosthetic Regurgitation. J Am Coll Cardiol. 2011;58(21):2218-24. doi: 10.1016/j.jacc.2011.07.041.</mixed-citation>
			</ref>
			<ref id="B9">
				<label>9</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Pate</surname>
							<given-names>GE</given-names>
						</name>
						<name>
							<surname>Al Zubaidi</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Chandavimol</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Thompson</surname>
							<given-names>CR</given-names>
						</name>
						<name>
							<surname>Munt</surname>
							<given-names>BI</given-names>
						</name>
						<name>
							<surname>Webb</surname>
							<given-names>JG</given-names>
						</name>
					</person-group>
					<article-title>Percutaneous Closure of Prosthetic Paravalvular Leaks: Case Series and Review</article-title>
					<source>Catheter Cardiovasc Interv</source>
					<year>2006</year>
					<volume>68</volume>
					<issue>4</issue>
					<fpage>528</fpage>
					<lpage>533</lpage>
					<pub-id pub-id-type="doi">10.1002/ccd.20795</pub-id>
				</element-citation>
				<mixed-citation>9 Pate GE, Al Zubaidi A, Chandavimol M, Thompson CR, Munt BI, Webb JG. Percutaneous Closure of Prosthetic Paravalvular Leaks: Case Series and Review. Catheter Cardiovasc Interv. 2006;68(4):528-33. doi: 10.1002/ccd.20795.</mixed-citation>
			</ref>
			<ref id="B10">
				<label>10</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Zoghbi</surname>
							<given-names>WA</given-names>
						</name>
						<name>
							<surname>Jone</surname>
							<given-names>PN</given-names>
						</name>
						<name>
							<surname>Chamsi-Pasha</surname>
							<given-names>MA</given-names>
						</name>
						<name>
							<surname>Chen</surname>
							<given-names>T</given-names>
						</name>
						<name>
							<surname>Collins</surname>
							<given-names>KA</given-names>
						</name>
						<name>
							<surname>Desai</surname>
							<given-names>MY</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Guidelines for the Evaluation of Prosthetic Valve Function With Cardiovascular Imaging: A Report From the American Society of Echocardiography Developed in Collaboration With the Society for Cardiovascular Magnetic Resonance and the Society of Cardiovascular Computed Tomography</article-title>
					<source>J Am Soc Echocardiogr</source>
					<year>2024</year>
					<volume>37</volume>
					<issue>1</issue>
					<fpage>2</fpage>
					<lpage>63</lpage>
					<pub-id pub-id-type="doi">10.1016/j.echo.2023.10.004</pub-id>
				</element-citation>
				<mixed-citation>10 Zoghbi WA, Jone PN, Chamsi-Pasha MA, Chen T, Collins KA, Desai MY, et al. Guidelines for the Evaluation of Prosthetic Valve Function With Cardiovascular Imaging: A Report From the American Society of Echocardiography Developed in Collaboration With the Society for Cardiovascular Magnetic Resonance and the Society of Cardiovascular Computed Tomography. J Am Soc Echocardiogr. 2024;37(1):2-63. doi: 10.1016/j.echo.2023.10.004.</mixed-citation>
			</ref>
			<ref id="B11">
				<label>11</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Quercioli</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Capettini</surname>
							<given-names>AC</given-names>
						</name>
						<name>
							<surname>Gherli</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Secco</surname>
							<given-names>GG</given-names>
						</name>
					</person-group>
					<article-title>Three-dimensional Echo Guidance of Percutaneous Mitral Paravalvular Leak Closure</article-title>
					<source>Eur Heart J</source>
					<year>2021</year>
					<volume>42</volume>
					<issue>4</issue>
					<fpage>359</fpage>
					<lpage>359</lpage>
					<pub-id pub-id-type="doi">10.1093/eurheartj/ehaa593</pub-id>
				</element-citation>
				<mixed-citation>11 Quercioli A, Capettini AC, Gherli R, Secco GG. Three-dimensional Echo Guidance of Percutaneous Mitral Paravalvular Leak Closure. Eur Heart J. 2021;42(4):359. doi: 10.1093/eurheartj/ehaa593.</mixed-citation>
			</ref>
			<ref id="B12">
				<label>12</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Barreiro-Perez</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Cruz-González</surname>
							<given-names>I</given-names>
						</name>
						<name>
							<surname>Gil-Ortega</surname>
							<given-names>MV</given-names>
						</name>
						<name>
							<surname>Rasco</surname>
							<given-names>AG</given-names>
						</name>
						<name>
							<surname>Sánchez</surname>
							<given-names>PL</given-names>
						</name>
					</person-group>
					<article-title>Photo-Realistic Echocardiography Imaging During Percutaneous Paravalvular Leak Closure</article-title>
					<source>JACC Cardiovasc Interv</source>
					<year>2020</year>
					<volume>13</volume>
					<issue>20</issue>
					<fpage>185</fpage>
					<lpage>187</lpage>
					<pub-id pub-id-type="doi">10.1016/j.jcin.2020.08.031</pub-id>
				</element-citation>
				<mixed-citation>12 Barreiro-Perez M, Cruz-González I, Gil-Ortega MV, Rasco AG, Sánchez PL. Photo-Realistic Echocardiography Imaging During Percutaneous Paravalvular Leak Closure. JACC Cardiovasc Interv. 2020;13(20):185-7. doi: 10.1016/j.jcin.2020.08.031.</mixed-citation>
			</ref>
			<ref id="B13">
				<label>13</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ruparelia</surname>
							<given-names>N</given-names>
						</name>
						<name>
							<surname>Cao</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Newton</surname>
							<given-names>JD</given-names>
						</name>
						<name>
							<surname>Wilson</surname>
							<given-names>N</given-names>
						</name>
						<name>
							<surname>Daniels</surname>
							<given-names>MJ</given-names>
						</name>
						<name>
							<surname>Ormerod</surname>
							<given-names>OJ</given-names>
						</name>
					</person-group>
					<article-title>Paravalvular Leak Closure Under Intracardiac Echocardiographic Guidance</article-title>
					<source>Catheter Cardiovasc Interv</source>
					<year>2018</year>
					<volume>91</volume>
					<issue>5</issue>
					<fpage>958</fpage>
					<lpage>965</lpage>
					<pub-id pub-id-type="doi">10.1002/ccd.27318</pub-id>
				</element-citation>
				<mixed-citation>13 Ruparelia N, Cao J, Newton JD, Wilson N, Daniels MJ, Ormerod OJ. Paravalvular Leak Closure Under Intracardiac Echocardiographic Guidance. Catheter Cardiovasc Interv. 2018;91(5):958-65. doi: 10.1002/ccd.27318.</mixed-citation>
			</ref>
			<ref id="B14">
				<label>14</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Smolka</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Pysz</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>Ochała</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Kozłowski</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Zasada</surname>
							<given-names>W</given-names>
						</name>
						<name>
							<surname>Parma</surname>
							<given-names>Z</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Transcatheter Paravalvular Leak Closure and Hemolysis - A Prospective Registry</article-title>
					<source>Arch Med Sci</source>
					<year>2017</year>
					<volume>13</volume>
					<issue>3</issue>
					<fpage>575</fpage>
					<lpage>584</lpage>
					<pub-id pub-id-type="doi">10.5114/aoms.2016.60435</pub-id>
				</element-citation>
				<mixed-citation>14 Smolka G, Pysz P, Ochała A, Kozłowski M, Zasada W, Parma Z, et al. Transcatheter Paravalvular Leak Closure and Hemolysis - A Prospective Registry. Arch Med Sci. 2017;13(3):575-84. doi: 10.5114/aoms.2016.60435.</mixed-citation>
			</ref>
			<ref id="B15">
				<label>15</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Karagodin</surname>
							<given-names>I</given-names>
						</name>
						<name>
							<surname>Shah</surname>
							<given-names>AP</given-names>
						</name>
						<name>
							<surname>Lang</surname>
							<given-names>RM</given-names>
						</name>
					</person-group>
					<article-title>Guided by the Light-Transillumination of a Paravalvular Leak</article-title>
					<source>JAMA Cardiol</source>
					<year>2020</year>
					<volume>5</volume>
					<issue>8</issue>
					<elocation-id>e203260</elocation-id>
					<pub-id pub-id-type="doi">10.1001/jamacardio.2020.3260</pub-id>
				</element-citation>
				<mixed-citation>15 Karagodin I, Shah AP, Lang RM. Guided by the Light-Transillumination of a Paravalvular Leak. JAMA Cardiol. 2020;5(8):e203260. doi: 10.1001/jamacardio.2020.3260.</mixed-citation>
			</ref>
			<ref id="B16">
				<label>16</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ahmed</surname>
							<given-names>HF</given-names>
						</name>
						<name>
							<surname>Petersen</surname>
							<given-names>JW</given-names>
						</name>
						<name>
							<surname>Bavry</surname>
							<given-names>AA</given-names>
						</name>
						<name>
							<surname>Alhussaini</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Beaver</surname>
							<given-names>TM</given-names>
						</name>
					</person-group>
					<article-title>Paravalvular Leak Closure with Real Time Transesophageal Echocardiography and Fluoroscopy Fusion</article-title>
					<source>JRSM Cardiovasc Dis</source>
					<year>2020</year>
					<volume>9</volume>
					<fpage>2048004020947290</fpage>
					<lpage>2048004020947290</lpage>
					<pub-id pub-id-type="doi">10.1177/2048004020947290</pub-id>
				</element-citation>
				<mixed-citation>16 Ahmed HF, Petersen JW, Bavry AA, Alhussaini M, Beaver TM. Paravalvular Leak Closure with Real Time Transesophageal Echocardiography and Fluoroscopy Fusion. JRSM Cardiovasc Dis. 2020;9:2048004020947290. doi: 10.1177/2048004020947290.</mixed-citation>
			</ref>
			<ref id="B17">
				<label>17</label>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Wang</surname>
							<given-names>DD</given-names>
						</name>
						<name>
							<surname>Qian</surname>
							<given-names>Z</given-names>
						</name>
						<name>
							<surname>Vukicevic</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Engelhardt</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Kheradvar</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Zhang</surname>
							<given-names>C</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>3D Printing, Computational Modeling, and Artificial Intelligence for Structural Heart Disease</article-title>
					<source>JACC Cardiovasc Imaging</source>
					<year>2021</year>
					<volume>14</volume>
					<issue>1</issue>
					<fpage>41</fpage>
					<lpage>60</lpage>
					<pub-id pub-id-type="doi">10.1016/j.jcmg.2019.12.022</pub-id>
				</element-citation>
				<mixed-citation>17 Wang DD, Qian Z, Vukicevic M, Engelhardt S, Kheradvar A, Zhang C, et al. 3D Printing, Computational Modeling, and Artificial Intelligence for Structural Heart Disease. JACC Cardiovasc Imaging. 2021;14(1):41-60. doi: 10.1016/j.jcmg.2019.12.022.</mixed-citation>
			</ref>
		</ref-list>
	</back>
	<sub-article article-type="translation" id="S1" xml:lang="pt">
		<front-stub>
			<article-id pub-id-type="doi">10.36660/abcimg.20240034</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Artigo de Revisão</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Como Eu Faço Abordagem para Avaliação de Leak Paraprotético Mitral</article-title>
			</title-group>
			<contrib-group>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0002-3543-754X</contrib-id>
					<name>
						<surname>Bignoto</surname>
						<given-names>Tiago</given-names>
					</name>
					<role>Concepção e desenho da pesquisa</role>
					<role>obtenção de dados</role>
					<role>análise e interpretação dos dados</role>
					<role>análise estatística</role>
					<role>obtenção de financiamento</role>
					<role>redação do manuscrito e revisão crítica do manuscrito quanto ao conteúdo intelectual importante</role>
					<xref ref-type="aff" rid="aff2"><sup>1</sup></xref>
					<xref ref-type="corresp" rid="c2"/>
				</contrib>
				<aff id="aff2">
					<label>1</label>
					<addr-line>
						<named-content content-type="city">São Paulo</named-content>
						<named-content content-type="state">SP</named-content>
					</addr-line>
					<country country="BR">Brasil</country>
					<institution content-type="original">Universidade de São Paulo, Cardiopatia Estrutural, São Paulo, SP – Brasil</institution>
				</aff>
			</contrib-group>
			<author-notes>
				<corresp id="c2"><bold>Correspondência: Tiago Bignoto</bold> • Universidade de São Paulo, Cardiopatia Estrutural. Avenida Dr. Enéas Carvalho de Aguiar, 44. CEP: <postal-code>05403-900</postal-code>. São Paulo, SP – Brasil E-mail: <email>tiagobignoto@yahoo.com.br</email>
				</corresp>
				<fn fn-type="edited-by">
					<p>Editor responsável pela revisão: Marcelo Tavares</p>
				</fn>
				<fn fn-type="conflict">
					<p><bold>Potencial Conflito de Interesse</bold></p>
					<p>Declaro não haver conflito de interesses pertinentes.</p>
				</fn>
			</author-notes>
			<abstract>
				<title>Resumo</title>
				<p>O <italic>leak</italic> paraprotético mitral é uma condição comum, embora seja frequentemente assintomática. Quando apresenta manifestações clínicas, como insuficiência cardíaca e/ou hemólise, o tratamento intervencionista está indicado. Recentemente, a abordagem transcateter ganhou destaque e, para isso, é necessária uma avaliação por métodos de imagem no planejamento. A ecocardiografia é o método mais utilizado e as informações a serem verificadas e confirmadas são gravidade, localização, tamanho, forma e o número de vazamentos (<italic>leaks</italic>). Uma vez definidas essas variáveis, o planejamento de abordagem é realizado, sendo a via transeptal a mais utilizada. A decisão do melhor lugar de punção septal depende de vários fatores, mas a localização precisa do pertuito é o mais importante. Uma vez realizado o posicionamento dos dispositivos, a avaliação ecocardiográfica intraoperatória determina o sucesso do procedimento e orienta necessidades de reposicionamento e ajustes, bem como sinaliza eventuais complicações que possam ocorrer.</p>
			</abstract>
			<kwd-group xml:lang="pt">
				<title>Palavras-chave</title>
				<kwd>Valva Mitral</kwd>
				<kwd>Próteses Valvulares Cardíacas</kwd>
				<kwd>Doenças das Valvas Cardíacas</kwd>
			</kwd-group>
		</front-stub>
		<body>
			<sec sec-type="intro">
				<title>Introdução</title>
				<p>O <italic>leak</italic> paraprotético ocorre quando surge um refluxo ao redor de uma prótese valvar e pode ter diversas causas.<sup><xref ref-type="bibr" rid="B1">1</xref>–<xref ref-type="bibr" rid="B4">4</xref></sup> Na maioria das vezes são achados incidentais tendo repercussão clínica em apenas 5% dos indivíduos. As manifestações clínicas relacionadas incluem queixas como insuficiência cardíaca em 85% dos casos e/ou hemólise clinicamente significativa em até 47%.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
				<p>Com uma prevalência de até 17%, o mecanismo é diverso e, algumas vezes, pouco compreendido. Pode ocorrer um distanciamento entre o anel de sutura e o anel valvar nativo por calcificação excessiva, evento infeccioso ou questões técnicas durante a cirurgia.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B3">3</xref></sup> Na topografia da valva mitral, esse achado é encontrado em até 15% dos pacientes submetidos à troca valvar mitral.<sup><xref ref-type="bibr" rid="B5">5</xref></sup></p>
				<p>Conforme as últimas diretrizes,<sup><xref ref-type="bibr" rid="B2">2</xref>–<xref ref-type="bibr" rid="B4">4</xref></sup> o reparo do vazamento deve ser considerado em pacientes com clínica de insuficiência cardíaca ou hemólise significativa.</p>
				<p>Diante do risco crescente em novas abordagens cirúrgicas, o tratamento transcateter tem sido cada vez mais frequente em casos de anatomias favoráveis em centros especializados. No entanto, algumas complicações podem acontecer, como interferência do dispositivo implantado com a prótese ou estrutura anatômica adjacente.</p>
				<p>Cirurgia de urgência ou morte podem ocorrer em até 4%. Enquanto o desfecho composto de morte, infarto do miocárdio, acidente vascular cerebral, sangramento maior e cirurgia de urgência em 30 dias pode atingir até 8,7%.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref></sup></p>
				<p>A taxa de sucesso técnico do fechamento percutâneo foi relatada em 86%, e houve uma melhora na classe funcional de até 77%.<sup><xref ref-type="bibr" rid="B6">6</xref></sup> Ruiz <italic>et al</italic>.<sup><xref ref-type="bibr" rid="B7">7</xref></sup> relataram sobrevivência a longo prazo aos 6, 12 e 18 meses como 91,9, 89,2 e 86,5%, respectivamente. Sorajja <italic>et al</italic>.<sup><xref ref-type="bibr" rid="B8">8</xref></sup> encontraram sobrevida de 75% de 1 a 2 anos após o fechamento percutâneo de <italic>leak</italic> paraprotético, com uma taxa de sobrevivência estimada em 3 anos de 64,5%.</p>
				<p>Durante um <italic>screening</italic> realizado em ambiente pelo <italic>Heart Team</italic>, aspectos relevantes do diagnóstico por imagem são fundamentais para a decisão terapêutica. Um estudo abrangente é obrigatório, incluindo a ecocardiografia transtorácica com a identificação e classificação do grau do refluxo, além de uma complementação transesofágica utilizando imagens tridimensionais.<sup><xref ref-type="bibr" rid="B4">4</xref>,<xref ref-type="bibr" rid="B6">6</xref></sup></p>
				<p>Antes de programar uma possível abordagem, é essencial descartar quadros infecciosos locais ou sistêmicos, bem como a presença de trombos cavitários.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B9">9</xref></sup></p>
				<sec>
					<title>Avaliação por imagem do leak</title>
					<p>A elegibilidade do paciente e a programação para um possível fechamento começa com a obtenção de imagens de alta qualidade. Há uma variedade de métodos disponíveis para diagnosticar o <italic>leak</italic> paraprotético, incluindo o ecocardiograma transtorácico (ETT), ecocardiograma transesofágico (ETE), tomografia computadorizada (TC) e ressonância magnética (RM). Entre estes, não existe um método diagnóstico ideal, embora as imagens ecocardiográficas sejam mais usadas e o método mais difundido.</p>
					<p>Como vantagem, a ecocardiografia permite uma comparação direta das imagens pré-procedimento com os resultados intraprocedimento. No entanto, esse método de imagem apresenta propensão a artefatos específicos por sombras acústicas o que pode tornar a avaliação desafiadora. A complementação tridimensional (3D) melhora a definição espacial, acrescentando a capacidade de determinar o caminho de um vazamento, que muitas vezes pode seguir um curso serpiginoso.<sup><xref ref-type="bibr" rid="B10">10</xref></sup></p>
					<p>De forma superficial, as primeiras informações a serem verificadas e confirmadas são gravidade, localização, tamanho, forma e o número de vazamentos. Inicialmente, a prótese valvar é &quot;escaneada&quot; por meio de uma sistemática rotação da sonda de eco, que busca a presença de deiscência e/ou sinais paraprotéticos com o Doppler colorido.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B4">4</xref>,<xref ref-type="bibr" rid="B6">6</xref></sup></p>
					<p>O tipo de prótese e as técnicas utilizadas para seu implante são fundamentais durante a avaliação por imagem. A equipe deve estar ciente de vários fatores, desde a técnica usada para sutura até os possíveis materiais protéticos, como <italic>patches</italic>, que auxiliam a fixação.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
					<p>A avaliação do <italic>leak</italic> paraprotético deve se basear em múltiplos parâmetros e aspectos estruturais da anatomia do paciente. O primeiro passo é avaliar o movimento do dispositivo todo em relação ao anel nativo. Deslocamentos do dispositivo, em um movimento denominado &quot;<italic>Rock Motion</italic>&quot;, em quadros de <italic>leak</italic> paraprotético sinalizam grandes deiscências com mais de 40% do anel acometido. Em alguns casos, essa hipermobilidade pode ser secundária à mobilidade do tecido adjacente acometido por eventos infecciosos. Nesses casos, a abordagem transcateter está contraindicada e a avaliação de cirurgia convencional deve ser realizada o mais rápido possível (<xref ref-type="fig" rid="f4">Vídeo 1</xref>).<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
					<fig id="f4">
						<label>Video 1</label>
						<caption>
							<title>Imagem de ecocardiografia transtorácica, janela apical de 4 câmaras mostrando imagem de &quot;Rock Motion&quot; de prótese valvar mitral. Vídeo 1 – Imagem de ecocardiografia transtorácica, janela apical de 4 câmaras mostrando imagem de &quot;Rock Motion&quot; de prótese valvar mitral. Link: <ext-link ext-link-type="uri" xlink:href="http://abcimaging.org/supplementary-material/2024/3703/2024-0034_vïdeo_01.mp4">http://abcimaging.org/supplementary-material/2024/3703/2024-0034_vïdeo_01.mp4</ext-link>
							</title>
						</caption>
						<media id="mf4" mime-subtype="mp4" mimetype="video" xlink:href="2675-312X-abcimg-37-02-e20240034-m01.mp4"/>
					</fig>
					<p>Descartada essa complicação, os parâmetros do Doppler precisam ser avaliados, conforme encontramos na <xref ref-type="table" rid="t2">Tabela 1</xref>.</p>
					<table-wrap id="t2">
						<label>Tabela 1</label>
						<caption>
							<title>Parâmetros ecocardiográficos para avaliar leak paraprotético mitral</title>
						</caption>
						<table frame="hsides" rules="groups">
							<colgroup width="14%">
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead style="border-top: thin solid; border-bottom: thin solid; border-color: #000000">
								<tr style="background-color:#C58874">
									<th align="left" valign="middle"/>
									<th align="center" valign="middle">Traço</th>
									<th align="center" valign="middle">Discreto</th>
									<th align="center" valign="middle">Discreto a Moderado</th>
									<th align="center" valign="middle">Moderado</th>
									<th align="center" valign="middle">Moderado a Importante</th>
									<th align="center" valign="middle">Importante</th>
								</tr>
							</thead>
							<tbody style="border-bottom: thin solid; border-color: #000000">
								<tr>
									<td align="left" valign="middle">VC, mm</td>
									<td align="center" valign="middle">Mínimo</td>
									<td align="center" valign="middle">&lt;2</td>
									<td align="center" valign="middle">2-3</td>
									<td align="center" valign="middle">3-5</td>
									<td align="center" valign="middle">5-7</td>
									<td align="center" valign="middle">≥7</td>
								</tr>
								<tr style="background-color:#E8CCBF">
									<td align="left" valign="middle">Circunferência, %</td>
									<td align="center" valign="middle">Mínimo</td>
									<td align="center" valign="middle">&lt;5</td>
									<td align="center" valign="middle">5-10</td>
									<td align="center" valign="middle">10-20</td>
									<td align="center" valign="middle">20-30</td>
									<td align="center" valign="middle">≥30</td>
								</tr>
								<tr>
									<td align="left" valign="middle">Vol. Reg., mL</td>
									<td align="center" valign="middle">&lt;10</td>
									<td align="center" valign="middle">&lt;15</td>
									<td align="center" valign="middle">15-30</td>
									<td align="center" valign="middle">30-45</td>
									<td align="center" valign="middle">45-60</td>
									<td align="center" valign="middle">≥60</td>
								</tr>
								<tr style="background-color:#E8CCBF">
									<td align="left" valign="middle">FR, %</td>
									<td align="center" valign="middle">&lt;15</td>
									<td align="center" valign="middle">&lt;15</td>
									<td align="center" valign="middle">15-30</td>
									<td align="center" valign="middle">30-40</td>
									<td align="center" valign="middle">40-50</td>
									<td align="center" valign="middle">≥50</td>
								</tr>
								<tr>
									<td align="left" valign="middle">ERO, mm<sup>2</sup></td>
									<td align="center" valign="middle">&lt;5</td>
									<td align="center" valign="middle">&lt;5</td>
									<td align="center" valign="middle">5-20</td>
									<td align="center" valign="middle">20-30</td>
									<td align="center" valign="middle">30-40</td>
									<td align="center" valign="middle">≥40</td>
								</tr>
							</tbody>
						</table>
						<table-wrap-foot>
							<fn id="TFN2">
								<p>VC: Vena Contracta; Vol. Reg.: Volume regurgitante; FR: Fração regurgitante; ERO: área efetiva de regurgitação.</p>
							</fn>
						</table-wrap-foot>
					</table-wrap>
					<p>O primeiro passo é graduar a intensidade da regurgitação, bem como sua repercussão hemodinâmica. Parâmetros habitualmente utilizados na classificação ecocardiográfica de lesões de valvas nativas podem ser extrapolados com cautela para a avaliação do <italic>leak</italic> paraprotético.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
					<p>Avaliações das curvas de Doppler das veias pulmonares em <italic>leaks</italic> na topografia mitral e da aorta ascendente na topografia da aórtica parecem úteis em um primeiro momento. A observação de gradientes transprotéticos elevados mesmo com aspectos normais dos folhetos ou elementos móveis também sinaliza a possibilidade de hiperfluxo e <italic>leak</italic> paraprotético importante.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
					<p>Sinais de hipertrofia excêntrica progressiva compõem também o diagnóstico de gravidade da regurgitação sinalizando sobrecarga de volume importante.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
				</sec>
				<sec>
					<title>Localização</title>
					<p>A avaliação da localização e a forma de reportar os achados seguem um padrão comum nos laudos ecocardiográficos. De forma geral, utiliza-se a referência de um relógio na topografia do dispositivo em questão, seguindo a visualização do cirurgião em centro cirúrgico como na <xref ref-type="fig" rid="f5">Figura Central</xref>.<sup><xref ref-type="bibr" rid="B10">10</xref></sup></p>
					<fig id="f5">
						<caption>
							<title>Desenho esquemático da localização e orientação do leak paraprotético em prótese mitral.</title>
						</caption>
						<graphic xlink:href="2675-312X-abcimg-37-02-e20240034-gf01-pt.tif"/>
					</fig>
					<p>Para a posição mitral, tanto a orientação pelo mostrador de um relógio, quanto as relações anatômicas podem ser usadas. A localização é baseada no anel da valva mitral e é descrita como medial, lateral, anterior ou posterior. O mostrador do relógio começa na posição de 12 horas, na direção da valva aórtica, o que faz a posição das 3 horas ser na comissura posteromedial ou direção do septo interatrial e a posição das 6 horas no ponto médio do anel posterior. Essa localização detalhada do pertuito facilita a seleção ideal do local de punção transeptal.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref></sup></p>
				</sec>
			</sec>
			<sec>
				<title>Dimensões</title>
				<p>Embora o curso do vazamento possa ser serpiginoso, a avaliação da <italic>vena contracta</italic> do refluxo é um passo importante para sua classificação e para programar uma possível abordagem transcateter, incluindo a seleção de dispositivos a serem usados.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
				<p>Não há a recomendação de se cruzar o <italic>leak</italic> com cateteres balão para mensurar sua dimensão sob o risco de lesões iatrogênicas nesse procedimento.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
				<p>Para dimensionar com precisão o vazamento, tanto uma escala de cinza conjunto com dados de aquisição e fluxo de cores são usados. Com um software dedicado, um plano de corte paralelo ao anel é posicionado no nível do vazamento, permitindo derivar diâmetro e área máximo e mínimo (vide <xref ref-type="fig" rid="f6">Figura 1</xref>).<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
				<fig id="f6">
					<label>Figura 1</label>
					<caption>
						<title>Avaliação de dimensão e aspecto do leak paraprotético mitral. A) Etapas para cálculo da área da vena contracta e suas dimensões; B) Utilização do método 3D para realizar as medidas das dimensões do leak paraprotético; C e D) Avaliação em escalas de cores diferentes e com Doppler Colorido. Adaptado de Gafoor et al.<sup><xref ref-type="bibr" rid="B1">1</xref></sup> e Pysz et al.<sup><xref ref-type="bibr" rid="B6">6</xref></sup></title>
					</caption>
					<graphic xlink:href="2675-312X-abcimg-37-02-e20240034-gf02-pt.tif"/>
				</fig>
				<p>Uma das formas de melhor avaliar as dimensões do vazamento após sua localização é obter uma imagem com o menor volume possível contendo o trajeto completo do <italic>leak</italic>, com eletrocardiograma-Gated (ECG-Gated) em batimento único e uma alta taxa de volume (HVR) 3D. O modo com Doppler colorido é, então, adquirido. A seguir, procede-se à opacificação do <italic>leak</italic> pelo fluxo mapeado da turbulência vista pelo Doppler Colorido em análise multiplanar. Isto permite a visualização da forma da <italic>vena contracta</italic> do <italic>leak</italic> e a medição de suas dimensões.<sup><xref ref-type="bibr" rid="B6">6</xref></sup></p>
				<p>Recentemente, novas técnicas de renderização de imagens 3D foram introduzidas para permitir a visualização da morfologia do trajeto do <italic>leak</italic> de forma ainda mais detalhada, e posteriormente, para orientar eficientemente o procedimento intervencionista.</p>
				<sec>
					<title>Planejamento e intraoperatório</title>
					<p>O primeiro passo é a definição da via de acesso para a abordagem do vazamento. As opções de acessos venosos ou arteriais são possíveis em qualquer acometimento, mas devem ser selecionados de acordo com determinadas variações anatômicas. O acesso venoso femoral demanda a necessidade de uma punção transeptal para acessar o lado esquerdo, e esse procedimento é importante na programação de como manejar os cateteres no interior do átrio esquerdo.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref></sup></p>
					<p>É obtida uma visão do eixo curto da valva aórtica, entre 20 e 50 graus, com o foco no septo interatrial. Após isso, ativa-se o modo multiplanar e apresenta-se uma imagem ortogonal, que corresponde à vista bicaval.<sup><xref ref-type="bibr" rid="B11">11</xref></sup></p>
					<p>Para <italic>leak</italic>s mitrais, a escolha do local de punção transeptal deve ser orientada pela localização do pertuito, pois tal abordagem aumenta muito as chances de sucesso. Uma punção central geralmente é ideal, dada a altura acima do anel mitral suficiente para acomodar a curvatura da bainha dirigível (geralmente por volta de 2,5 cm, dependendo do modelo e tamanho da bainha).<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B9">9</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
					<p>Conceitualmente, o pertuito do <italic>leak</italic> é cruzado de forma anterógrada por uma abordagem transeptal e o fechamento é feito de forma retrógrada, puxando o dispositivo do ventrículo esquerdo em direção ao átrio esquerdo.<sup><xref ref-type="bibr" rid="B11">11</xref></sup></p>
					<p>Para <italic>leak</italic>s mitrais na região anterior, uma punção mais superior pode ser melhor, pois geralmente melhora a coaxialidade durante a travessia. O <italic>leak</italic> mitral localizado posteriormente continua sendo o mais desafiador para acesso. Geralmente é necessária uma punção baixa e posterior para obter a melhor coaxialidade permitindo o cruzamento. No entanto, isso pode ser limitado pelas relações anatômicas individuais entre o tamanho da fossa oval e o ângulo em que a veia cava inferior entra no átrio direito.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B9">9</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
					<p>Em casos de anatomia hostil do acesso mitral, o acesso arterial transfemoral retrógrado pode ser utilizado pela facilidade anatômica de abordagem do vazamento.<sup><xref ref-type="bibr" rid="B6">6</xref></sup> A abordagem transapical por toracotomia pode ser usada para facilitar o posicionamento anatômico, mas é geralmente considerada uma medida excepcional.<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
					<p>De forma geral, usa-se um fio hidrofílico para cruzar o vazamento, seguido de um cateter diagnóstico. Na sequência o fio é trocado por um mais rígido, guiado tanto pela escopia, quanto pela ecocardiografia transesofágica intraoperatória.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
					<p>A ecocardiografia intraoperatória é um passo fundamental na realização do procedimento, pois é importante no suporte desde uma possível punção transeptal, até o cruzamento do vazamento com fios e cateteres e a liberação topográfica dos dispositivos oclusores. Além disso, é fundamental na detecção precoce de complicações graves como tamponamento ou risco de emaranhamento de fios intracavitários.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B9">9</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
					<p>Em casos de um pertuito estreito ou anatomicamente distorcido, se posicionar e cruzar pode ser um grande desafio. Nesses casos, uma vez que a ponta do cateter for colocada próximo ao orifício do <italic>leak</italic>, conforme avaliado pela ecocardiografia 3D transesofágica, pode ser interessante voltar para a imagem biplanar com Doppler colorido. Isto permite direcionar os movimentos suaves do cateter e/ou fios em direção ao pertuito, simultaneamente em duas direções, com resolução temporal e espacial da imagem superior ao 3D.<sup><xref ref-type="bibr" rid="B6">6</xref></sup></p>
					<p>Em casos selecionados, para evitar riscos da ecocardiografia transesofágica e a anestesia associada, o uso da ecocardiografia intracardíaca pode ser uma alternativa, embora tenha limitações técnicas frente aos aparelhos de ecocardiografia transesofágica quanto a definição espacial e ainda seja indisponível na maioria dos serviços nacionais.<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B10">10</xref>,<xref ref-type="bibr" rid="B12">12</xref>,<xref ref-type="bibr" rid="B13">13</xref></sup></p>
					<p>Os dispositivos de fechamento são escolhidos de 2 a 3 mm maiores do que o diâmetro aferido. Uma vez que estejam posicionados e totalmente abertos no interior do pertuito, mas ainda presos aos introdutores, a ecocardiografia deve ser direcionada para avaliar os resultados imediatos. Isso deve envolver repercussão na mobilidade da prótese ali localizada, jato de regurgitação residual com avaliação de <italic>vena contracta</italic> e área efetiva de regurgitação (ERO) e de parâmetros de repercussão hemodinâmica avaliados pelo Doppler como gradientes transprotéticos, fluxo em veias pulmonares, dentre outros parâmetros.<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B10">10</xref></sup></p>
					<p>Existem poucos dispositivos projetados especificamente para a oclusão de <italic>leaks</italic> paraprotéticos, portanto, adaptações acabam sendo rotineiras no planejamento dessa intervenção. Diante disso, muitas vezes não há um dispositivo ideal, mas é importante considerar a interferência nos folhetos protéticos ou elementos móveis, bem como estruturas anatômicas adjacentes, como a via de saída do ventrículo esquerdo.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
					<p>Vale ressaltar que o operador deve se atentar às condições hemodinâmicas do momento da avaliação intraprocedimento para realizar as comparações com o pré-procedimento, muito pela presença de uma anestesia ou sedação profunda.<sup><xref ref-type="bibr" rid="B6">6</xref></sup></p>
					<p>Embora hemodinamicamente uma regurgitação residual discreta não tenha grandes repercussões, nenhuma lesão residual deve ser tolerada pelo risco de desenvolvimento de hemólise clinicamente significativa pós-procedimento, o que não traria benefícios clínicos ao paciente. Diante de lesões moderadas ou graves, é necessário ponderar sobre o reposicionamento dos dispositivos oclusores, e considerar a inclusão de mais algum ou até mesmo a seleção de alternativas com formatos diferentes.<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B14">14</xref></sup></p>
					<p>O acompanhamento ecocardiográfico e laboratorial, com o objetivo de avaliar a regurgitação residual ou hemólise, deve ocorrer pelo menos a cada seis meses ou quando houver alterações nas queixas do paciente. Embora sejam raros, deslocamentos dos dispositivos podem ocorrer, gerando algum grau de regurgitação ou hemólise ao longo dos anos.<sup><xref ref-type="bibr" rid="B1">1</xref></sup></p>
				</sec>
				<sec>
					<title>Novos métodos de imagem e situações especiais</title>
					<p>Em alguns casos, novas técnicas e ferramentas podem ser utilizadas com o intuito de melhorar a visualização e definição espacial. A transiluminação (Philips®), uma nova ferramenta de renderização 3D que utiliza uma fonte de luz móvel para melhorar a percepção de profundidade, pode ser usada para localizar melhor o <italic>leak</italic> paraprotético.<sup><xref ref-type="bibr" rid="B15">15</xref></sup> Outra ferramenta promissora nesse contexto é a imagem de fusão entre a ecocardiografia e a escopia. Em casos de sombras acústicas devido a próteses que apresentam uma limitação significativa ao ETE, o uso do software <italic>EchoNavigator,</italic> já empregado em procedimentos transcateter de outras valvopatias, pode ser uma ferramenta útil para orientar a equipe intervencionista.<sup><xref ref-type="bibr" rid="B16">16</xref></sup></p>
					<p>A produção de modelos impressos em 3D para o adequado planejamento da intervenção e, também, para treinamento em centros formadores tem emergido como técnica interessante. O primeiro passo é adquirir os dados da imagem em alta qualidade em um formato DICOM (<italic>Digital Imaging and Communication in Medicine</italic>), seja pela ecocardiografia, tomografia ou outro método. Esses dados são processados e exportados em formatos de arquivos de estereolitografia que, então, é usado pela impressora 3D.<sup><xref ref-type="bibr" rid="B17">17</xref></sup></p>
				</sec>
				<sec>
					<title>Considerações finais</title>
					<p>O uso dos métodos de imagem no screening adequado e durante o intraprocedimento do fechamento percutâneo do <italic>leak</italic> paraprotético em topografia mitral é fundamental e tem impacto prognostico relevante. Uma discussão adequada em ambiente de Heart Team é um passo decisivo, e o ecocardiografista desempenha um papel central nesse procedimento.</p>
				</sec>
			</sec>
		</body>
		<back>
			<fn-group>
				<fn fn-type="financial-disclosure">
					<p><bold>Fontes de Financiamento</bold></p>
					<p>O presente estudo não teve fontes de financiamento externas.</p>
				</fn>
				<fn fn-type="other" id="fn5">
					<p><bold>Vinculação Acadêmica</bold></p>
					<p>Não há vinculação deste estudo a programas de pós-graduação.</p>
				</fn>
				<fn fn-type="other" id="fn6">
					<p><bold>Ethics Approval and Consent to Participate</bold></p>
					<p>Este artigo não contém estudos com humanos ou animais realizados por nenhum dos autores.</p>
				</fn>
			</fn-group>
		</back>
	</sub-article>
</article>