<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "http://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="review-article" dtd-version="1.1" specific-use="sps-1.9" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">ijcs</journal-id>
      <journal-title-group>
        <journal-title>International Journal of Cardiovascular Sciences</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Int J Cardiovasc Sci</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">2359-4802</issn>
      <issn pub-type="epub">2359-5647</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id specific-use="scielo-v3" pub-id-type="publisher-id">MGs4sLC43Y7FtP7Sdy4JgHg</article-id>
      <article-id specific-use="scielo-v2" pub-id-type="publisher-id">S2359-56472020000500537</article-id>
      <article-id pub-id-type="publisher-id">ijcs.20200089</article-id>
      <article-id pub-id-type="doi">10.36660/ijcs.20200089</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>REVIEW ARTICLE</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Transcatheter Aortic Valve Implantation: Where are we in 2020?</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-9674-8528</contrib-id>
          <name>
            <surname>Sarmento-Leite</surname>
            <given-names>Rogerio</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
          <xref ref-type="aff" rid="aff2">
            <sup>2</sup>
          </xref>
          <xref ref-type="aff" rid="aff3">
            <sup>3</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-5483-1833</contrib-id>
          <name>
            <surname>Oliveira</surname>
            <given-names>Gilberto Eder de</given-names>
            <suffix>Junior</suffix>
          </name>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
      </contrib-group>
      <aff id="aff1">
        <label> 1 </label>
        <institution content-type="orgname">Instituto de Cardiologia do Rio Grande do Sul</institution>
        <addr-line>
          <named-content content-type="city">Porto Alegre</named-content>
          <named-content content-type="state">RS</named-content>
        </addr-line>
        <country country="BR">Brazil</country>
        <institution content-type="original"> Instituto de Cardiologia do Rio Grande do Sul , Porto Alegre , RS - Brazil </institution>
      </aff>
      <aff id="aff2">
        <label> 2 </label>
        <institution content-type="orgname">Hospital Moinhos de Vento</institution>
        <addr-line>
          <named-content content-type="city">Porto Alegre</named-content>
          <named-content content-type="state">RS</named-content>
        </addr-line>
        <country country="BR">Brazil</country>
        <institution content-type="original"> Hospital Moinhos de Vento , Porto Alegre , RS - Brazil </institution>
      </aff>
      <aff id="aff3">
        <label> 3 </label>
        <institution content-type="orgname">Universidade Federal de Ci&#234;ncias da Sa&#250;de de Porto Alegre</institution>
        <addr-line>
          <named-content content-type="city">Porto Alegre</named-content>
          <named-content content-type="state">RS</named-content>
        </addr-line>
        <country country="BR">Brazil</country>
        <institution content-type="original"> Universidade Federal de Ci&#234;ncias da Sa&#250;de de Porto Alegre , Porto Alegre , RS - Brazil </institution>
      </aff>
      <author-notes>
        <corresp id="c01">Mailing Address: Sarmento-Leite R Instituto de Cardiologia - Avenida Princesa Isabel, 395. Postal Code 90620-000, Porto Alegre, RS &#8211; Brazil. E-mail: <email>rsl.sarmento@gmail.com</email> , <email>geoliveirajr22@gmail.com</email> </corresp>
        <fn fn-type="con">
          <p>Author Contributions</p>
          <p>Writing of the manuscript: Oliveira J&#250;nior GE. Critical revision of the manuscript for intellectual content: Oliveira J&#250;nior GE, Sarmento-Leite R.</p>
        </fn>
        <fn fn-type="conflict">
          <p>Potential Conflict of Interest</p>
          <p>No potential conflict of interest relevant to this article was reported.</p>
        </fn>
      </author-notes>
      <pub-date date-type="pub" publication-format="electronic">
        <day>28</day>
        <month>08</month>
        <year>2020</year>
      </pub-date>
      <pub-date date-type="collection" publication-format="electronic">
        <season>Sep-Oct</season>
        <year>2020</year>
      </pub-date>
      <volume>33</volume>
      <issue>5</issue>
      <fpage>537</fpage>
      <lpage>549</lpage>
      <history>
        <date date-type="received">
          <day>28</day>
          <month>04</month>
          <year>2020</year>
        </date>
        <date date-type="rev-recd">
          <day>04</day>
          <month>05</month>
          <year>2020</year>
        </date>
        <date date-type="accepted">
          <day>04</day>
          <month>05</month>
          <year>2020</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/" xml:lang="en">
          <license-p>This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
        </license>
      </permissions>
      <abstract>
        <title>Abstract</title>
        <p>Aortic stenosis is an insidious disease of rapid progression after the onset of symptoms. Aortic valve replacement surgery is a well-established therapy that reduces symptoms and increases survival rates. However, the procedure may be associated with high operative mortality rates and promote comorbidity. Depending on the local reality, the prevalence of patients considered inoperable (due to medical comorbidities and age) may achieve 30%. For these patients, transcatheter aortic valve implantation (TAVI) was initially indicated; over time, the method has advanced technologically and been simplified, and become an alternative therapy for patients at low and intermediate surgical risk also, and considered one of the major advances of modern medicine.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>Aortic Valve Stenosis</kwd>
        <kwd>Percutaneous Aortic Valve Replacement</kwd>
        <kwd>Aged</kwd>
        <kwd>Risk Factors</kwd>
        <kwd>Morbidity</kwd>
        <kwd>Mortality</kwd>
      </kwd-group>
      <counts>
        <fig-count count="3"/>
        <table-count count="2"/>
        <equation-count count="0"/>
        <ref-count count="105"/>
      </counts>
    </article-meta>
  </front>
  <body>
    <sec sec-type="intro">
      <title>Introduction</title>
      <p>Aortic stenosis is an insidious disease with a long latency period. It has a rapid progression after the onset of symptoms, resulting in a high mortality rate (approximately 50% in the first two years) in untreated asymptomatic patients, <sup><xref ref-type="bibr" rid="B1">1</xref> - <xref ref-type="bibr" rid="B3">3</xref></sup> in whom sudden death is common. Duration of asymptomatic stage is variable. The prevalence of aortic stenosis is increasing due to population aging and is considered the most common valve disease requiring intervention. <sup><xref ref-type="bibr" rid="B4">4</xref></sup></p>
      <p>Valve replacement surgery for treatment of aortic stenosis reduces symptoms and increases survival rates. <sup><xref ref-type="bibr" rid="B5">5</xref> - <xref ref-type="bibr" rid="B7">7</xref></sup> In general, surgical mortality is 1-3% in individuals younger than 70 years and 408% in the elderly. Despite the higher risk, age alone cannot be considered an absolute contraindication, since favorable outcomes have been reported even in patients aged 80 or older. <sup><xref ref-type="bibr" rid="B8">8</xref> - <xref ref-type="bibr" rid="B10">10</xref></sup></p>
      <p>In clinical practice, surgical treatment is not indicated for nearly 30% of patients (this can vary from one region to another) due to high-risk medical conditions. <sup><xref ref-type="bibr" rid="B11">11</xref> - <xref ref-type="bibr" rid="B14">14</xref></sup> Some of these include advanced age, female sex, functional class, surgical emergency, ventricular dysfunction, pulmonary hypertension, previous cardiac surgery, and coronary artery disease. In these cases, a less invasive procedure &#8211; transcatheter aortic valve implantation (TAVI) &#8211; may be indicated.</p>
      <p>TAVI was first performed in 2002 by Professor Alain Cribier, who showed that it was possible to repair severe aortic stenosis by TAVI in a critically-ill patient. <sup><xref ref-type="bibr" rid="B15">15</xref></sup> With global dissemination and accumulated experience, technological advances in TAVI have been made; the technique has been simplified and become a low-risk therapeutic option for patients at intermediate surgical risk. In the last 15 years, more than 350,000 procedures have been performed in approximately 70 countries. <sup><xref ref-type="bibr" rid="B16">16</xref></sup> medicine.</p>
      <sec>
        <title>Indications</title>
        <p>Based on recent studies, indications for TAVI now encompass all risk groups. Clinical benefits of TAVI was initially shown in patients with severe calcific aortic stenosis, advanced age and high surgical risk (The Society of Thoracic Surgeons, STS &gt; 10%, Euroscore &gt; 4%). The most relevant studies have shown that TAVI is not inferior to heart valve replacement surgery in terms of one-year follow-up mortality in high-risk patients. In addition, compared to standard therapy, it would be necessary to treat five patients to prevent one death in one-year period. <sup><xref ref-type="bibr" rid="B17">17</xref> , <xref ref-type="bibr" rid="B18">18</xref></sup></p>
        <p>TAVI has also become a therapeutic option to treat patients with STS-defined intermediate risk since publication of the PARTNER2 <sup><xref ref-type="bibr" rid="B19">19</xref></sup> and SURTAVI <sup><xref ref-type="bibr" rid="B20">20</xref></sup> clinical trials.</p>
        <p>In 2020, with publication of the PARTNER3 <sup><xref ref-type="bibr" rid="B21">21</xref></sup> and EVOLUT LOW RISK <sup><xref ref-type="bibr" rid="B22">22</xref></sup> clinical trials, TAVI has been recognized as one the main revolutionary therapies of contemporary medicine and become indicated for low-risk patients also (STS&lt;4%). The PARTNER3 study, conducted in 71 centers with patients with mean age of 73 years and STS 1.9%, showed the superiority of TAVI for the primary composite endpoint (death, stroke and rehospitalization) in one-year follow-up. The secondary endpoints showed a lower incidence of new atrial fibrillation within 30 days, lower hospitalization rates and more effective control of heart failure-related symptoms (according to the KCCQ score and the 6-minute walk test). The EVOLUT LOW RISK, <sup><xref ref-type="bibr" rid="B22">22</xref></sup> conducted on patients at same age range, analyzed the composite endpoint of death and stroke in 24-month follow-up. The study showed lower incidence of debilitating stroke, acute renal failure, bleeding-related complications, and atrial fibrillation. On the other hand, the study showed higher incidence of moderate-to-severe aortic regurgitation and need for pacemaker implantation.</p>
        <p>A study conducted by the FDA with 30 days of follow-up showed zero mortality in low-risk patients treated with TAVI, as well as a shorter length of hospital stay and lower incidence of atrial fibrillation, corroborating the safety of the therapy. <sup><xref ref-type="bibr" rid="B23">23</xref></sup> Clinical and echocardiographic results have been recently published in the five&#8208;year follow-up NOTION clinical trial. Despite its limitations, including the small number of participants, the study brings relevant results of a longer follow-up. The study concluded that there were no significant differences between the patients undergoing TAVR and patients undergoing surgical aortic valve replacement in all-cause mortality, stroke, or myocardial infarction. <sup><xref ref-type="bibr" rid="B24">24</xref></sup></p>
        <p>Calcification of tricuspid prosthetic valve is considered the most common cause of aortic stenosis, as shown in Figure 1 . This entity is no longer considered &#8220;degenerative&#8221; because of its complex and highly regulated pathophysiological basis, marked by an active and highly regulated process. It involves mechanisms that may occur simultaneously and contribute to disease development, including chronic inflammation, lipoprotein deposition, activation of the renin-angiotensin system, osteoblastic transformation of valvular interstitial cells and active calcification. <sup><xref ref-type="bibr" rid="B25">25</xref> - <xref ref-type="bibr" rid="B28">28</xref></sup></p>
        <p>
          <fig id="f01">
            <label>Figure 2</label>
            <caption>
              <title>&#8211; Calcified bicuspid (A) and tricspid (B)aortic valve 32 </title>
            </caption>
            <graphic xlink:href="2359-5647-ijcs-33-05-0537-00089-gf01.tif"/></fig>
        </p>
        <p>The incidence of bicuspid aortic valve stenosis is higher in young than in older subjects. Individuals older than 80 years account for approximately 20% of surgeries. <sup><xref ref-type="bibr" rid="B29">29</xref></sup> Some anatomical features of this condition, such as the oval-shaped annulus, and uneven calcification and size of the leaflets, may lead to less predictable outcomes of the TAVI. However, a recent meta-analysis with 13 observational studies including data of 758 patients with bicuspid valves showed a successful rate of 95% of the procedure. <sup><xref ref-type="bibr" rid="B30">30</xref> , <xref ref-type="bibr" rid="B31">31</xref></sup> Early events rates, including all-cause mortality, stroke, life-threatening bleeding, vascular complications and valve dysfunction, were not different between patients with bicuspid and tricuspid valves. Also, no difference was found in the rate of annular rupture between the groups. However, a higher need for pacemaker implantation was observed and the combined incidence of moderate-to-severe paravalvular regurgitation was 12.2%. <sup><xref ref-type="bibr" rid="B30">30</xref></sup></p>
        <p>Valve-in-valve (ViV) TAVI has emerged as a novel, less invasive approach for bioprosthetic aortic valve degeneration treatment. The use of the MEDTRONIC (CoreValve, Evolute R and Evolut Pro) and EDWARDS (SAPIEN XT and SAPIEN 3) valves have been approved for high-risk patients. Recently, results of the PARTNER 2 ViV registry <sup><xref ref-type="bibr" rid="B33">33</xref></sup> of a study on the safety and effectiveness of self-expanding TAVI <sup><xref ref-type="bibr" rid="B34">34</xref></sup> have been published. The first study reported 30-day and one-year mortality rates at one year of 2.7% and 12.4%, respectively, and in the second, these rates were of 2.2% and 14.6%, respectively. Moderate or severe aortic regurgitation occurred in 3.5% of the patients. Factors significantly associated with higher residual aortic gradients were surgical valve size, stenosis as modality of surgical valve failure, and presence of surgical valve prosthesis-patient mismatch. <sup><xref ref-type="bibr" rid="B33">33</xref> , <xref ref-type="bibr" rid="B34">34</xref></sup></p>
        <p>A recent review of five meta-analyses <sup><xref ref-type="bibr" rid="B35">35</xref> - <xref ref-type="bibr" rid="B39">39</xref></sup> comparing ViV TAVI to the new surgical procedure showed similar mortality rates (in-hospital, 30-day and one-year mortality) between the groups, even considering that patients that underwent ViV TAVI were at higher surgical risk. Thirty-day mortality of ViV TAVI reported in these meta-analyses was not different than that reported in the VIVID registry, <sup><xref ref-type="bibr" rid="B40">40</xref></sup> with a non-significant tendency toward a higher rate in the VIVI-registry (7.6% vs. 4.4%, p&gt;0.05).</p>
        <p>The experience has shown that complications of ViV TAVI can be prevented. Patients with small surgical bioprostheses represent a particular challenge, as they seem to show higher residual gradient and higher late mortality than patients undergoing ViV TAVI. Supra-annular bioprosthetic valves and a high implant could mitigate this complication. <sup><xref ref-type="bibr" rid="B41">41</xref></sup> More recently, some researches have described a technique involving bioprosthetic valve fracture with a high-pressure balloon to facilitate ViV TAVI. The strategy seemed to facilitate the expansion of the transcatheter valve, with reduction of residual transvalvular pressure gradients. <sup><xref ref-type="bibr" rid="B42">42</xref></sup></p>
      </sec>
      <sec>
        <title>Clinical Indication</title>
        <p>According to recent guidelines, TAVI is indicated for symptomatic patients with an average gradient greater than or equal to 4m/s. For patients with low gradient and low flow, valve area smaller than or equal to 1cm <sup>2</sup> , and reduced ejection fraction, the indication continues for those with preserved flow reserve (which can be analyzed by dobutamine stress echocardiogram). For patients with preserved ejection fraction and no flow reserve, the severity of stenosis can be estimated by calculation of calcium score by computed tomography. <sup><xref ref-type="bibr" rid="B43">43</xref></sup></p>
      </sec>
      <sec>
        <title>Immediate and Late Results</title>
        <p>After successful valve replacement surgery, the symptoms and quality of life generally improve, although with a longer recovery time as compared with TAVI. Operatory mortality rates vary from 1 to 8%, and long-term survival is comparable to that in the general elderly population of same age. <sup><xref ref-type="bibr" rid="B8">8</xref> - <xref ref-type="bibr" rid="B10">10</xref></sup> Younger subjects have shown substantial improvement with valve replacement surgery compared with conservative medical therapy, with low survival rates though. Risk factors for late mortality include age, comorbidities, severe symptoms, left ventricular dysfunction, ventricular arrythmias and untreated coronary artery disease. <sup><xref ref-type="bibr" rid="B44">44</xref> , <xref ref-type="bibr" rid="B45">45</xref></sup></p>
        <p>For those cases with well-defined indications, TAVI has been shown as a feasible procedure. Constant improvement in early mortality and complication rates has been shown with accumulated experience, improved pre-procedural image processing and better techniques regarding respective valves and delivery systems. While 30-day mortality rates varied from 5% to 15% in the first reports, <sup><xref ref-type="bibr" rid="B17">17</xref> , <xref ref-type="bibr" rid="B46">46</xref> - <xref ref-type="bibr" rid="B48">48</xref></sup> more recent studies using late-degeneration devices have shown a decrease by 1-2% in these rates, varying from 5% to 7%. <sup><xref ref-type="bibr" rid="B49">49</xref> , <xref ref-type="bibr" rid="B50">50</xref></sup></p>
        <p>With respect to long term survival, studies have reported a one-year survival rate of 60-85% in patients at high risk, greatly depending on the severity of comorbidities, <sup><xref ref-type="bibr" rid="B17">17</xref> , <xref ref-type="bibr" rid="B18">18</xref> , <xref ref-type="bibr" rid="B46">46</xref> , <xref ref-type="bibr" rid="B48">48</xref> , <xref ref-type="bibr" rid="B51">51</xref> - <xref ref-type="bibr" rid="B53">53</xref></sup> reaching 95% in patients at intermediate risk. Although improvement of health and quality of life at one year after TAVI is comparable to that seen in open surgeries, it emerges faster in case of TAVI, due to its less invasive nature. <sup><xref ref-type="bibr" rid="B45">45</xref> , <xref ref-type="bibr" rid="B52">52</xref></sup> Long-term durability of these procedures has been carefully studied, although no difference has been reported in five-year outcomes between transcatheter and surgical bioprosthetic aortic valves. <sup><xref ref-type="bibr" rid="B54">54</xref> , <xref ref-type="bibr" rid="B55">55</xref></sup></p>
        <p><xref ref-type="table" rid="t1">Table 1</xref> summarizes the main outcomes of TAVI of clinical trials. Overall and individual analyses showed that vascular complication rates, need for pacemaker implantation, and paravalvular regurgitation rates were higher in TAVI than conventional open surgery. <sup><xref ref-type="bibr" rid="B20">20</xref> , <xref ref-type="bibr" rid="B56">56</xref></sup> On the other hand, severe bleeding, acute renal injury and new-onset atrial fibrillation were significantly more frequent in open surgery than TAVI, and no statistically significant difference was seen in cerebrovascular event rates. <sup><xref ref-type="bibr" rid="B19">19</xref> , <xref ref-type="bibr" rid="B56">56</xref></sup></p>
        <p>
          <table-wrap id="t1">
            <label>Table 1</label>
            <caption>
              <title>&#8211; Outcomes of transcatheter aortic-valve implantation obtained from clinical trials</title>
            </caption>
            <table frame="hsides" rules="groups">
              <colgroup width="13%">
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
              </colgroup>
              <thead>
                <tr>
                  <th align="left" style="font-weight:normal"> </th>
                  <th>Partner A</th>
                  <th>Partner B</th>
                  <th>Partner 2</th>
                  <th>Core Valve</th>
                  <th>SURTAVI</th>
                  <th>Partner 3</th>
                  <th>ELR*</th>
                </tr>
              </thead>
              <tbody>
                <tr>
                  <td>N</td>
                  <td align="center">348</td>
                  <td align="center">179</td>
                  <td align="center">1011</td>
                  <td align="center">394</td>
                  <td align="center">879</td>
                  <td align="center">1000</td>
                  <td align="center">1403</td>
                </tr>
                <tr>
                  <td>Age</td>
                  <td align="center">83.6</td>
                  <td align="center">83.1</td>
                  <td align="center">81.5</td>
                  <td align="center">83.2</td>
                  <td align="center">79.9</td>
                  <td align="center">73.3</td>
                  <td align="center">74</td>
                </tr>
                <tr>
                  <td>Female (%)</td>
                  <td align="center">42.2</td>
                  <td align="center">54.2</td>
                  <td align="center">45.8</td>
                  <td align="center">46.4</td>
                  <td align="center">42.2</td>
                  <td align="center">32.5</td>
                  <td align="center">36</td>
                </tr>
                <tr>
                  <td>STS risk-score (%)</td>
                  <td align="center">11.8</td>
                  <td align="center">11.6</td>
                  <td align="center">5.8 +- 2.1</td>
                  <td align="center">7.3 +- 3</td>
                  <td align="center">4.4 +- 1.5</td>
                  <td align="center">1.9</td>
                  <td align="center">1.9</td>
                </tr>
                <tr>
                  <td>Prosthesis</td>
                  <td align="center">SAPIENTM</td>
                  <td align="center">SAPIENTM</td>
                  <td align="center">SAPIENTM XT</td>
                  <td align="center">Core Valve TM</td>
                  <td align="center">Core Valve TM (16% Evolut R TM)</td>
                  <td align="center">SAPIENTM3</td>
                  <td align="center">Core ValveTM Evolut RTM . Evolut PROTM</td>
                </tr>
                <tr>
                  <td>30-day mortality (%)</td>
                  <td align="center">3.4</td>
                  <td align="center">5</td>
                  <td align="center">3.9</td>
                  <td align="center">3.3</td>
                  <td align="center">2.2</td>
                  <td align="center">0.4</td>
                  <td align="center">0.5</td>
                </tr>
                <tr>
                  <td>30-day stroke (%)</td>
                  <td align="center">3.8</td>
                  <td align="center">6.7</td>
                  <td align="center">5.5</td>
                  <td align="center">4.9</td>
                  <td align="center">3.4</td>
                  <td align="center">0.6</td>
                  <td align="center">2.1</td>
                </tr>
                <tr>
                  <td>Moderate-to-severe regurgitation (%)</td>
                  <td align="center">13.1</td>
                  <td align="center">15</td>
                  <td align="center">3.7</td>
                  <td align="center">10</td>
                  <td align="center">5.3</td>
                  <td align="center">0.6</td>
                  <td align="center">4.3</td>
                </tr>
                <tr>
                  <td>Pacemaker (%)</td>
                  <td align="center">4.4</td>
                  <td align="center">3.4</td>
                  <td align="center">8.5</td>
                  <td align="center">19.8</td>
                  <td align="center">25.9</td>
                  <td align="center">7.3</td>
                  <td align="center">19.4</td>
                </tr>
                <tr>
                  <td>Vascular event (%)</td>
                  <td align="center">11</td>
                  <td align="center">16.2</td>
                  <td align="center">7.9</td>
                  <td align="center">5.9</td>
                  <td align="center">6</td>
                  <td align="center">2.8</td>
                  <td align="center">3.8</td>
                </tr>
                <tr>
                  <td>Major bleeding (%)</td>
                  <td align="center">9.3</td>
                  <td align="center">16.8</td>
                  <td align="center">10.4</td>
                  <td align="center">28.1</td>
                  <td align="center">12.2</td>
                  <td align="center">7.7</td>
                  <td align="center">3.2</td>
                </tr>
                <tr>
                  <td>Acute renal injury (%)</td>
                  <td align="center">2.9</td>
                  <td align="center">1.1</td>
                  <td align="center">1.3</td>
                  <td align="center">6</td>
                  <td align="center">1.7</td>
                  <td align="center">0.4</td>
                  <td align="center">0.9</td>
                </tr>
                <tr>
                  <td>New-onset AF (%)</td>
                  <td align="center">8.6</td>
                  <td align="center">0.6</td>
                  <td align="center">9.1</td>
                  <td align="center">11.7</td>
                  <td align="center">12.9</td>
                  <td align="center">7.0</td>
                  <td align="center">9.8</td>
                </tr>
                <tr>
                  <td>One-year mortality (%)</td>
                  <td align="center">24.3</td>
                  <td align="center">30.7</td>
                  <td align="center">12.3</td>
                  <td align="center">14.2</td>
                  <td align="center">6.7</td>
                  <td align="center">1.1</td>
                  <td align="center">2.4</td>
                </tr>
                <tr>
                  <td>Two-year mortality (%)</td>
                  <td align="center">33.9</td>
                  <td align="center">43.3</td>
                  <td align="center">16.7</td>
                  <td align="center">22.2</td>
                  <td align="center">11.4</td>
                  <td> </td>
                  <td> </td>
                </tr>
                <tr>
                  <td>Five-year mortality (%)</td>
                  <td align="center">67.8</td>
                  <td align="center">61.8</td>
                  <td align="center">-</td>
                  <td align="center">-</td>
                  <td> </td>
                  <td> </td>
                  <td> </td>
                </tr>
              </tbody>
            </table>
            <table-wrap-foot>
              <fn id="TFN1">
                <p>
                  <italic>*ELR=Evolut Low Risk Trial; STS: Society of Thoracic Surgery; AF: atrial fibrillation</italic>
                </p>
              </fn>
            </table-wrap-foot>
          </table-wrap>
        </p>
        <p>
          <fig id="f02">
            <label>Figure 3</label>
            <caption>
              <title>&#8211; Chronological sequence of published clinical trials 57 </title>
            </caption>
            <graphic xlink:href="2359-5647-ijcs-33-05-0537-00089-gf02.tif"/></fig>
        </p>
        <p>The decision towards a therapy is made based on clinical, anatomical, and technical aspects that may be considered alone or in combination. Some conditions, such as previous cardiac surgeries, restricted mobility, frailty, chest irradiation sequelae, porcelain aorta, chest deformity, marked scoliosis, and obesity favor the choice of TAVI. On the other hand, open surgery is the preferred procedures in case of unfavorable access for TAVI, suspected endocarditis, short distance between coronary ostia and annulus, ascending aorta aneurysm, aortic or left ventricular thrombus, other valvular dysfunction, coronary artery disease and need for bypass revascularization, and septal hypertrophy.</p>
      </sec>
      <sec>
        <title>Procedure</title>
        <p>In the periprocedural period, some aspects should be considered without compromising patient&#8217;s safety. The procedure may be performed in a cath lab instead of a hybrid room. If performed via a transfemoral approach, the presence of a cardiac surgeon is not obligatory, but the professional should be involved in the process and be available in case of complications. The staff should include at least two surgeons, one nurse and one X-ray technician. The presence of an echocardiographist, anaesthesiologist, cardiac surgeon, vascular surgeon and perfusionist in the catheterization laboratory is not an absolute requirement, but they should be involved in selected and more complex cases or in those at the initial phase of the learning curve. <sup><xref ref-type="bibr" rid="B58">58</xref></sup></p>
        <p>The first implants were conducted via an antegrade transseptal approach. Over the years, this approach has been abandoned in favor of the transfemoral approach, which is the method of choice, in addition to alternative routes (transapical, trans-aortic, trans-subclavian, transcarotid). An accurate analysis, guided by computed tomography coronary angiography, is essential for the selection of the access route, considering vessel anatomy, the profile and size of the device. <sup><xref ref-type="bibr" rid="B59">59</xref></sup></p>
        <p>Immediately after the procedure, all patients should be monitored in the hybrid operating room for at least 10-15 minutes, with special attention to hemodynamics and cardiac rhythm. Then, the patients should be transferred to a coronary care unit or to a cardiac telemetry unit, according to local protocols. Patients&#8217; clinical status, especially concerning the procedural outcomes, echocardiogram, and laboratory results, should be carefully evaluated. Mobilization should be prescribed a few hour later, in the absence of vascular access problems (e.g. hematoma or bleeding) and removal of temporary pacemaker. Patients without complications (or those whose complications were successfully managed) can be discharged on the next day. <sup><xref ref-type="bibr" rid="B58">58</xref></sup></p>
        <p>The efforts to accelerate recovery and mobilization require shorter hospitalization time and minimize unnecessary use of resources. Hospital discharge within 24-72 hours after the procedure seemed not to affect the safety of the procedure, as reported in previous studies. <sup><xref ref-type="bibr" rid="B60">60</xref> - <xref ref-type="bibr" rid="B62">62</xref></sup> A clinical protocol of early discharge tested at low-, medium-, and high-volume TAVI centers showed excellent safety and efficacy outcomes. <sup><xref ref-type="bibr" rid="B63">63</xref></sup> The most common problems involved in a prolonged hospitalization include conduction disturbances, bleeding and acute renal injury. Monitoring of atrioventricular block is by far the most important measure.</p>
        <p>The cost-benefit relationship of the minimalist approach in TAVI has not been well defined. In a small U.S. series of 142 patients (n=70 undergoing minimalistic transfemoral TAVI and n=72 undergoing standard transfemoral TAVI), it was demonstrated that that the minimalistic strategy decreased the cost of TAVI (USD 2,869 estimate) and could be used frequently to prevent costs associated with hybrid operating rooms and anesthesia. <sup><xref ref-type="bibr" rid="B64">64</xref></sup></p>
        <p>Although TAVI is a complex procedure, important advances toward its simplification have been made. In many centers, the minimalist approach has been routinely performed and shown to be as safe and effective as the standard approach.</p>
      </sec>
      <sec>
        <title>Complications</title>
        <p>Despite technical advances in the development of implantation techniques and devices, in addition to more possible procedures and indications, potential complications may occur and do require consideration and prevention. The first complications of TAVI were peri and post-procedural neurological, conduction disturbances, and events vascular complications, peri neurological events, and perivalvular regurgitation. <sup><xref ref-type="bibr" rid="B15">15</xref> , <xref ref-type="bibr" rid="B16">16</xref></sup> More recently, despite their low incidence, increasing interest has been devoted to aortic rupture and coronary occlusion due to their potential and severe impact. <sup><xref ref-type="bibr" rid="B34">34</xref> , <xref ref-type="bibr" rid="B65">65</xref></sup> However, other concerns have concomitantly emerged regarding durability and risk of thrombosis, since procedures have been performed in younger and at lower-risk patients. <sup><xref ref-type="bibr" rid="B66">66</xref> - <xref ref-type="bibr" rid="B68">68</xref></sup></p>
        <p>Therefore, the fact that TAVI is indicated for younger patients today make mandatory the recognition and monitoring of possible complications related to durability of the procedure, since these patients have higher life expectancy, and calcium metabolism that accelerates leaf calcification compared with those patients for whom TAVI was first indicated. Failure of the procedure may be related to deterioration (consequent to calcification, pannus or thrombus formation) or intraprosthetic regurgitation (e.g. reduced leaflet mobility and endocarditis). <sup><xref ref-type="bibr" rid="B69">69</xref></sup></p>
        <p>No significant increase in average gradient or structural valve deterioration was reported in the five-year follow-up in the PARTNER study. Results of follow-up of up to five years have also been described in other three studies, <sup><xref ref-type="bibr" rid="B70">70</xref> - <xref ref-type="bibr" rid="B72">72</xref></sup> two of them did not raise important issues regarding durability, with stable transprosthetic pressure gradient over time and dysfunction rates of 3.4% and 4.2%, respectively, based on different definitions.</p>
        <p>With respect to late durability, some studies have presented data from 7-8 year-follow-up using a SAPIEN (Edwards Lifesciences) or a CoreValve device. Three different studies conducted in one center reported stable transprosthetic gradient over time, and severe prosthetic dysfunction rates of 2.4%, 3.2% and 3,6%. <sup><xref ref-type="bibr" rid="B73">73</xref> - <xref ref-type="bibr" rid="B75">75</xref></sup> Holy et al., <sup><xref ref-type="bibr" rid="B76">76</xref></sup> evaluated long-term results of 152 consecutive patients undergoing TAVI with the self-expanding CoreValve between 2001 and 2011. <sup><xref ref-type="bibr" rid="B76">76</xref></sup> Echocardiographic follow-up at 6.3&#177;1.0 years (5.0-8.9 years) was 88% complete (60 out of 68 survivors beyond five years). No evidence of structural valve deterioration was reported, and five patients (3.3%) had undergone redo TAVI or surgery due to paravalvular leakage. Deutsch et al. reported an overall crude cumulative incidence of structural valve deterioration of 14.9% (CoreValve 11.8% vs. SAPIEN 22.6%; p=0.01) at seven years. <sup><xref ref-type="bibr" rid="B77">77</xref></sup></p>
        <p>Vascular complications such as bleeding, need for transfusion and hemodynamic instability were initially identified as major limitations of TAVI. However, with improvement of the devices and in patient selection, and accumulated experience, these complications have become rarer. Today, the mean complications are minor bleeding and direct damage such as dissection and occlusion of the vessel. <sup><xref ref-type="bibr" rid="B78">78</xref></sup></p>
        <p>Cerebrovascular events are associated with high morbidity and mortality. A meta-analysis of 64 studies involving 72,318 patients found an incidence of cerebrovascular events of 3.3% within 30 days post-TAVI. <sup><xref ref-type="bibr" rid="B79">79</xref></sup> Nearly half of the events occurred 24 hours following the procedure and the others attributed to catheter manipulation via aortic valve, balloon dilatation and prosthesis release. Neurological events clinically manifest as focal signs or even silent ischemia, detected by brain magnetic resonance imaging. <sup><xref ref-type="bibr" rid="B16">16</xref> , <xref ref-type="bibr" rid="B80">80</xref></sup> More recent studies have reported a favorable trend of decrease in the incidence of events to nearly 1.2% at one year, particularly with improvement of devices and growing experience. <sup><xref ref-type="bibr" rid="B21">21</xref></sup> In addition, protective devices have been developed to filter or deflect debris from cerebral vasculature.</p>
        <p>The most common conduction disturbances are left bundle branch block and total atrioventricular block. <sup><xref ref-type="bibr" rid="B81">81</xref></sup> Efforts have been made to prevent these complications, as they are associated with lower recovery of left ventricular function, greater need for pacemaker and rehospitalizations, and longer hospital stay. The assessment of valvular anatomy and selection of the most appropriate prosthesis not always minimize these effects.</p>
        <p>Paravalvular leak may occur and has been more commonly associated with TAVI and standard surgery. <sup><xref ref-type="bibr" rid="B16">16</xref> , <xref ref-type="bibr" rid="B82">82</xref></sup> The incidence of moderate-to-severe leakage in first generation devices were reported in 12-21% of the cases. <sup><xref ref-type="bibr" rid="B82">82</xref></sup> This deserves special attention and prevention, due to its relationship with high morbidity and mortality. <sup><xref ref-type="bibr" rid="B83">83</xref></sup> The three mechanisms involved are incomplete apposition of TAVI to the valve annulus because of severe calcification, undersizing and poor positioning of the prosthesis. In more recent series, the incidence of leakage significantly decreased, as mentioned previously. This is explained by a more precise evaluation of the valve annulus before surgery, by computed tomography angiography, ability to recapture, reposition and finely adjust the valve. Other improvements include sealing skirts or an additional external sealing layer to fill the gaps between the transcatheter prosthesis and the aortic annulus. <sup><xref ref-type="bibr" rid="B84">84</xref></sup></p>
        <p>Thrombosis of bioprostheses can occur by two different mechanisms: first, as symptomatic, obstructive valve thrombosis, with increased transvalvular gradient and reduced effectiveness of the orifice measured by echocardiography. This is a rare event, reported in approximately 0.5% of the patients undergoing TAVI. <sup><xref ref-type="bibr" rid="B85">85</xref> , <xref ref-type="bibr" rid="B86">86</xref></sup> Second, as asymptomatic, subclinical valve thrombosis, with thickening and reduced motion of prosthetic valve leaflets detected by computed tomography, with normal transvalvular gradients at transthoracic echocardiography. This has been more commonly reported patients treated via a percutaneous approach., with an incidence varying form 5% to 40% in patients with TAVI. <sup><xref ref-type="bibr" rid="B86">86</xref></sup> The RESOLVE and SAVORY, <sup><xref ref-type="bibr" rid="B68">68</xref></sup> an observational study on subclinical leaflet thrombosis has reported an incidence of 4% of this event in 138 patients undergoing standard surgery and 13% in 752 patients undergoing TAVI. Subclinical leaflet thrombosis was also less frequent in patients receiving anticoagulants, compared with those in double antiplatelet therapy (4% vs. 15%; p&lt; 0.0001). <sup><xref ref-type="bibr" rid="B68">68</xref></sup> An incomplete frame expansion of TAVI, as well its metallic nature seem to be two of the main risk factors for subclinical thrombosis. <sup><xref ref-type="bibr" rid="B84">84</xref></sup></p>
        <p>Endocarditis, although less common after valve replacement surgery (0.5-3.1%; <sup><xref ref-type="bibr" rid="B58">58</xref></sup> 1-6% <sup><xref ref-type="bibr" rid="B84">84</xref> , <xref ref-type="bibr" rid="B87">87</xref></sup> ), can be a severe complication. In a recent multicenter registry, including 250 post-TAVI patients, in-hospital mortality was 36% and two-year mortality 66.7%. <sup><xref ref-type="bibr" rid="B61">61</xref></sup> Younger age, male sex, family history of diabetes mellitus, and moderate-to-severe residual aortic regurgitation were significantly associated with increased risk of infectious endocarditis. <sup><xref ref-type="bibr" rid="B61">61</xref></sup> The most common causative agents of prosthetic valve endocarditis were Staphylococci (31.5%), Enterococcus (20%) and Streptococcus (14%). <sup><xref ref-type="bibr" rid="B87">87</xref></sup></p>
        <p>Although the possibility of late failure of transcatheter aortic valve replacement is regarded as a major concern, preliminary observations revealed that, in contrast to reoperation following the conventional surgical procedure, which is technically challenging with a significant risk of morbidity and mortality, the redo TAVI seems to be safe and effective. <sup><xref ref-type="bibr" rid="B62">62</xref></sup></p>
        <p>In summary, understanding the complications is extremely important for the planning of the procedure. The association of these complications with patients&#8217; profile has become more and more important, since, as evidence has shown, indication of TAVI has been expanded for younger and at lower-risk patients.</p>
        <p>With the aim of defining endpoints that reflect clinical efficacy of the device and patients&#8217; safety, the Valve Academic Research Consortium (VARC) consensus was created in 2011. One year later, the document was updated, with the objective to broaden the understanding of risk stratification of the patient and selection of the cases, and to revise the endpoints for the development of clinical trials. Thus, the so-called VARC-2 recommends the inclusion of a time-related valve safety, which combines valve dysfunction, endocarditis, and thrombotic complications. <xref ref-type="table" rid="t2">Table 2</xref> describes the composite endpoints defined in this document. <sup><xref ref-type="bibr" rid="B88">88</xref></sup></p>
        <p>
          <table-wrap id="t2">
            <label>Table 2</label>
            <caption>
              <title>&#8211; Composite endpoints defined by the VARC2 88 </title>
            </caption>
            <table frame="hsides" rules="groups">
              <colgroup width="100%">
                <col/>
              </colgroup>
              <tbody>
                <tr>
                  <td>
                    <list list-type="simple">
                      <list-item>
                        <p>
                          <bold>Device success</bold>
                        </p>
                      </list-item>
                      <list-item>
                        <p>Absence of periprocedural mortality AND</p>
                      </list-item>
                      <list-item>
                        <p>Correct anatomical positioning AND</p>
                      </list-item>
                      <list-item>
                        <p>Intended performance of the prosthesis (no prosthesis-patient mismatch and mean aortic valve gradient&lt;20 mm Hg or peak velocity&lt;3 m/s, and no moderate-to-severe aortic valve regurgitation)</p>
                      </list-item>
                    </list>
                  </td>
                </tr>
                <tr>
                  <td>
                    <list list-type="simple">
                      <list-item>
                        <p>
                          <bold>Early safety</bold>
                        </p>
                      </list-item>
                      <list-item>
                        <p>All-cause mortality</p>
                      </list-item>
                      <list-item>
                        <p>Stroke</p>
                      </list-item>
                      <list-item>
                        <p>Major bleeding</p>
                      </list-item>
                      <list-item>
                        <p>Acute kidney injury</p>
                      </list-item>
                      <list-item>
                        <p>Coronary artery obstruction requiring intervention</p>
                      </list-item>
                      <list-item>
                        <p>Major vascular complication</p>
                      </list-item>
                      <list-item>
                        <p>Valve-related dysfunction requiring repeat procedure (BAV, TAVI, SAVR)</p>
                      </list-item>
                    </list>
                  </td>
                </tr>
                <tr>
                  <td>
                    <list list-type="simple">
                      <list-item>
                        <p>
                          <bold>Clinical efficacy</bold>
                        </p>
                      </list-item>
                      <list-item>
                        <p>All-cause mortality</p>
                      </list-item>
                      <list-item>
                        <p>Stroke</p>
                      </list-item>
                      <list-item>
                        <p>Requiring hospitalizations for valve dysfunction or heart failure-related symptoms</p>
                      </list-item>
                      <list-item>
                        <p>NYHA class III or IV</p>
                      </list-item>
                      <list-item>
                        <p>Valve dysfunction (mean aortic valve gradient &#8805; 20 mm Hg, EOA &#8804; 0.9&#8211;1.1 cm2 and/or DVI&lt;0. 35 m/s, and/or moderate-to-severe valve regurgitation)</p>
                      </list-item>
                    </list>
                  </td>
                </tr>
                <tr>
                  <td>
                    <list list-type="simple">
                      <list-item>
                        <p>
                          <bold>Long-term safety</bold>
                        </p>
                      </list-item>
                      <list-item>
                        <p>Structural valve deterioration</p>
                      </list-item>
                      <list-item>
                        <p>Valve dysfunction (mean aortic valve gradient &#8805;20 mm Hg, EOA &#8804;0.9-1.1 cm2 and/or DVI&lt;0.35 m/s, and/or moderate-to-severe valve regurgitation</p>
                      </list-item>
                      <list-item>
                        <p>Requiring repeat procedure (TAVI or SAVR)</p>
                      </list-item>
                      <list-item>
                        <p>Prosthetic valve endocarditis</p>
                      </list-item>
                      <list-item>
                        <p>Prosthetic valve thrombosis</p>
                      </list-item>
                      <list-item>
                        <p>Thromboembolic events (e.g., stroke)</p>
                      </list-item>
                      <list-item>
                        <p>Bleeding, unless clearly unrelated to valve therapy (eg, trauma)</p>
                      </list-item>
                    </list>
                  </td>
                </tr>
              </tbody>
            </table>
            <table-wrap-foot>
              <fn id="TFN2">
                <p>
                  <italic>BAV: Balloon aortic valvuloplasty; TAVI: transcatheter aortic valve implantation; SAVR: surgical aortic valve replacement</italic>
                </p>
              </fn>
            </table-wrap-foot>
          </table-wrap>
        </p>
      </sec>
      <sec>
        <title>Antithrombotic Therapy</title>
        <p>Current guidelines are based mainly on specialists&#8217; opinions and recommend double antiplatelet therapy in the first six months, followed by low dose aspiring throughout life. For patients with atrial fibrillation (AF), the use of vitamin k antagonists is recommended. <sup><xref ref-type="bibr" rid="B89">89</xref> , <xref ref-type="bibr" rid="B90">90</xref></sup></p>
        <p>AF is a predictor of stroke and systemic embolism and can be found in up to one third of patients with indications for TAVI. Due to the need for anticoagulation, patients undergoing TAVI are at increased risk for hemorrhagic events after the procedure and during follow-up. <sup><xref ref-type="bibr" rid="B91">91</xref></sup> In case of hemorrhagic complications in patients with concomitant AF, mortality at one year after TAVI increases to 50%. <sup><xref ref-type="bibr" rid="B92">92</xref></sup> Therefore, evaluation of the ideal antithrombotic therapy in this population should be carefully considered.</p>
        <p>The use of novel oral anticoagulants (NOACs) in patients undergoing TAVI, without formal indication for anticoagulant therapy is still under investigation. In the recent GALILEO study, <sup><xref ref-type="bibr" rid="B93">93</xref></sup> the use of rivaroxaban at a dose of 10 mg daily (combined with aspirin at a dose of 75 to 100 mg) was tested in 1,644 after successful TAVI. A higher incidence of death, thromboembolic complications and life-threatening bleeding was observed in the rivaroxaban group compared with the antiplatelet group. Additional studies evaluating the effects of other NOAC are ongoing, including the ATLANTIS and the ENVISAGE-TAVI AF, and their results are expected to be published soon.</p>
      </sec>
      <sec>
        <title>Guidelines</title>
        <p>According to the American Heart Association (AHA), American College of Cardiology (ACC) and Society of Thoracic Surgery (STS), indications for TAVI have changed to high-risk patients (class I; level of evidence A) and as alternative therapy for patients at intermediate risk (class IIa; level of evidence B). <sup><xref ref-type="bibr" rid="B94">94</xref></sup> European guidelines have followed the same trend, corroborating the indication for patients at intermediate or high surgical risk (STS score or EuroSCORE &gt; 4%) and mainly for elderly, inoperable patients (class I; level of evidence B). <sup><xref ref-type="bibr" rid="B43">43</xref></sup></p>
        <p>
          <fig id="f03">
            <label>Figure 6</label>
            <caption>
              <title>&#8211; Geographic dispersion of transcatheter aortic-valve implantation in the world. The legend indicates the number of procedures per 1,000,000 inhabitants. 95 </title>
            </caption>
            <graphic xlink:href="2359-5647-ijcs-33-05-0537-00089-gf03.tif"/></fig>
        </p>
      </sec>
      <sec>
        <title>Future Perspectives</title>
        <p>Today, the greatest challenges are related to TAVI durability, and several limitations prevent a more robust evaluation. First, TAVI is a relatively young technology, since its use started to expand only after the procedure received the CE mark in 2007 and was approved by the US Food and Drug Administration in 2011. This means that there may be few data available on valve durability during periods longer than 10 years. Second, currently available data from five-year follow-up studies a related to first generation devices, implanted by relative inexperienced operators, with higher rates of improper positioning of the valve and size-related problems. Finally, the main limitation of durability over time is older age of patients, multiple comorbidities and the high risk due to lower life expectancy, and consequently a small number of patients (generally less than 50% of initial population) in the long-term follow-up.</p>
        <p>Another important issue is the optimization of antithrombotic therapy after device implantation. As previously mentioned, ongoing studies are expected to be published soon, and can modify or not currently established practices.</p>
      </sec>
      <sec>
        <title>Aortic Regurgitation</title>
        <p>Data are still limited for analysis of safety and efficacy of TAVI in patients with pure aortic regurgitation. Its application, even in those at high surgical risk is off-label. Most devices that have been approved worldwide are for the treatment of aortic stenosis.</p>
        <p>The prevalence of aortic regurgitation increases with age and affects nearly 13% of patients with native left-sided valvular heart disease. The symptoms tended to disappear late in the course of the disease with the onset of left ventricular dilatation and systolic dysfunction. Patients with ejection fraction lower than 30% have an annual mortality risk of 20%. <sup><xref ref-type="bibr" rid="B96">96</xref></sup></p>
        <p>Based on current European and North American guidelines, a surgical procedure should be considered for patients with moderate or severe symptomatic aortic regurgitation, and reduced left ventricular systolic function (&lt;50%) or severe left ventricular dilatation (left ventricular end-systolic diameter &gt; 50mm, left ventricular end-diastolic diameter &gt; 65-70mm; or left ventricular end-systolic volume &gt;45mL/m <sup>2</sup> ). <sup><xref ref-type="bibr" rid="B97">97</xref> , <xref ref-type="bibr" rid="B98">98</xref></sup> However, there is a high-risk subgroup of inoperable patients for whom TAVI should be considered.</p>
        <p>The main challenge for TAVI procedure is the absence of annular and leaflet calcification, which is required for anchoring and stabilization of the device during its implantation. The lack of calcium, secondary increased systolic volume, and dilation of the aortic root are limitations for proper positioning of the prosthesis and predispose to moderate or severe embolization or regurgitation after the procedure (which are associated with worse clinical outcomes). <sup><xref ref-type="bibr" rid="B99">99</xref></sup> Migration of the valve may occur in the aorta or deeper in the left ventricle up to several hours post-implantation. Over-dimensioning of the valve has been proposed to reduce the risk of migration &#8211; an oversizing of 15-20% has been recommended - no greater than that, to avoid the risk of annular rupture and abnormalities in the conduction system. <sup><xref ref-type="bibr" rid="B100">100</xref> , <xref ref-type="bibr" rid="B101">101</xref></sup></p>
        <p>New generation devices, such as the CoreValve, Evolut R, ACURATE neo, Lotus and Sapien 3, have some resources that make them different from previous devices. Characteristics like ability of retrieval and repositioning in the case of self-expansible, and adaptative sealing skirt of the Sapien 3 and Lotus, enable a more controlled and predictable TAVI. <sup><xref ref-type="bibr" rid="B102">102</xref> , <xref ref-type="bibr" rid="B103">103</xref></sup> The authors reported the safety and early clinical efficacy of TAVI in 254 patients from 46 centers. The authors reported the device success, defined according to the VARC-2 criteria, of 67%. <sup><xref ref-type="bibr" rid="B104">104</xref></sup> Yoon et al., <sup><xref ref-type="bibr" rid="B105">105</xref></sup> studied 331 patients from 40 centers, and reported a device success of 74.3%. <sup><xref ref-type="bibr" rid="B105">105</xref></sup></p>
      </sec>
    </sec>
  </body>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="B1">
        <label>1</label>
        <mixed-citation>1. Cheitlin MD , Gertz EW , Brundage BH , Carlson CJ , Quash JA , Bode Jr RS . Rate of progression of severity of valvular aortic stenosis in the adult . Am Heart J 1979 ; 98 ( 6 ): 689 - 700 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Cheitlin</surname>
              <given-names>MD</given-names>
            </name>
            <name>
              <surname>Gertz</surname>
              <given-names>EW</given-names>
            </name>
            <name>
              <surname>Brundage</surname>
              <given-names>BH</given-names>
            </name>
            <name>
              <surname>Carlson</surname>
              <given-names>CJ</given-names>
            </name>
            <name>
              <surname>Quash</surname>
              <given-names>JA</given-names>
            </name>
            <name>
              <surname>Bode</surname>
              <given-names>RS</given-names>
              <suffix>Jr</suffix>
            </name>
          </person-group>
          <article-title>Rate of progression of severity of valvular aortic stenosis in the adult</article-title>
          <source>Am Heart J</source>
          <year>1979</year>
          <volume>98</volume>
          <issue>6</issue>
          <fpage>689</fpage>
          <lpage>700</lpage>
        </element-citation>
      </ref>
      <ref id="B2">
        <label>2</label>
        <mixed-citation>2. Davies SW , Gershlick AH , Balcon R . Progression of valvular aortic stenosis: a long-term retrospective study . Eur Heart J 1991 ; 12 ( 1 ): 10 - 4 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Davies</surname>
              <given-names>SW</given-names>
            </name>
            <name>
              <surname>Gershlick</surname>
              <given-names>AH</given-names>
            </name>
            <name>
              <surname>Balcon</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
          <article-title>Progression of valvular aortic stenosis: a long-term retrospective study</article-title>
          <source>Eur Heart J</source>
          <year>1991</year>
          <volume>12</volume>
          <issue>1</issue>
          <fpage>10</fpage>
          <lpage>14</lpage>
        </element-citation>
      </ref>
      <ref id="B3">
        <label>3</label>
        <mixed-citation>3. Otto CM , Pearlman AS , Gardner CL . Hemodynamic progression of aortic stenosis in adults assessed by Doppler echocardiography . J Am Coll Cardiol 1989 ; 13 ( 3 ): 545 - 50 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Otto</surname>
              <given-names>CM</given-names>
            </name>
            <name>
              <surname>Pearlman</surname>
              <given-names>AS</given-names>
            </name>
            <name>
              <surname>Gardner</surname>
              <given-names>CL</given-names>
            </name>
          </person-group>
          <article-title>Hemodynamic progression of aortic stenosis in adults assessed by Doppler echocardiography</article-title>
          <source>J Am Coll Cardiol</source>
          <year>1989</year>
          <volume>13</volume>
          <issue>3</issue>
          <fpage>545</fpage>
          <lpage>550</lpage>
        </element-citation>
      </ref>
      <ref id="B4">
        <label>4</label>
        <mixed-citation>4. Nkomo VT , Gardin JM , Skelton TN , Gottdiener JS , Scott CG , Sarano ME . Burden of valvular heart diseases: a population-based study . Lancet 2006 ; 368 ( 9540 ): 1005 &#8211; 11 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Nkomo</surname>
              <given-names>VT</given-names>
            </name>
            <name>
              <surname>Gardin</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Skelton</surname>
              <given-names>TN</given-names>
            </name>
            <name>
              <surname>Gottdiener</surname>
              <given-names>JS</given-names>
            </name>
            <name>
              <surname>Scott</surname>
              <given-names>CG</given-names>
            </name>
            <name>
              <surname>Sarano</surname>
              <given-names>ME</given-names>
            </name>
          </person-group>
          <article-title>Burden of valvular heart diseases: a population-based study</article-title>
          <source>Lancet</source>
          <year>2006</year>
          <volume>368</volume>
          <issue>9540</issue>
          <fpage>1005</fpage>
          <lpage>1011</lpage>
        </element-citation>
      </ref>
      <ref id="B5">
        <label>5</label>
        <mixed-citation>5. Schwarz F , Baumann P , Manthey J , Hoffman M , Schuler G , Mehmel HC . The effect of aortic valve replacement on survival . Circulation 1982 ; 66 ( 5 ): 1105 - 10 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Schwarz</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Baumann</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Manthey</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Hoffman</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Schuler</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Mehmel</surname>
              <given-names>HC</given-names>
            </name>
          </person-group>
          <article-title>The effect of aortic valve replacement on survival</article-title>
          <source>Circulation</source>
          <year>1982</year>
          <volume>66</volume>
          <issue>5</issue>
          <fpage>1105</fpage>
          <lpage>1110</lpage>
        </element-citation>
      </ref>
      <ref id="B6">
        <label>6</label>
        <mixed-citation>6. Murphy ES , Lawson RM , Starr A , Rahimtoola SH . Severe aortic stenosis in patients 60 years of age or older: left ventricular function and 10-year survival aftervalve replacement . Circulation 1981 ; 64 ( 2 Pt 2 ): II - 184&#8211;8 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Murphy</surname>
              <given-names>ES</given-names>
            </name>
            <name>
              <surname>Lawson</surname>
              <given-names>RM</given-names>
            </name>
            <name>
              <surname>Starr</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Rahimtoola</surname>
              <given-names>SH</given-names>
            </name>
          </person-group>
          <article-title>Severe aortic stenosis in patients 60 years of age or older: left ventricular function and 10-year survival aftervalve replacement</article-title>
          <source>Circulation</source>
          <year>1981</year>
          <volume>64</volume>
          <issue>2</issue>
          <supplement>Pt 2</supplement>
          <fpage>II</fpage>
          <lpage>184&#8211;8</lpage>
        </element-citation>
      </ref>
      <ref id="B7">
        <label>7</label>
        <mixed-citation>7. Lund O . Preoperative risk evaluation and stratification of long-term survival after valve replacement for aortic stenosis: reasons for earlier operative intervention . Circulation 1990 ; 82 ( 1 ): 124 - 39 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Lund</surname>
              <given-names>O</given-names>
            </name>
          </person-group>
          <article-title>Preoperative risk evaluation and stratification of long-term survival after valve replacement for aortic stenosis: reasons for earlier operative intervention</article-title>
          <source>Circulation</source>
          <year>1990</year>
          <volume>82</volume>
          <issue>1</issue>
          <fpage>124</fpage>
          <lpage>139</lpage>
        </element-citation>
      </ref>
      <ref id="B8">
        <label>8</label>
        <mixed-citation>8. Dewey TM , Brown D , Ryan WH , Hebert MA , Prince SL , Mack MJ . Reliability of risk algorithms in predicting early and late operative outcomes in high-risk patients undergoing aortic valve replacement . J Thorac Cardiovasc Surg 2008 ; 135 ( 1 ): 180 &#8211; 7 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Dewey</surname>
              <given-names>TM</given-names>
            </name>
            <name>
              <surname>Brown</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Ryan</surname>
              <given-names>WH</given-names>
            </name>
            <name>
              <surname>Hebert</surname>
              <given-names>MA</given-names>
            </name>
            <name>
              <surname>Prince</surname>
              <given-names>SL</given-names>
            </name>
            <name>
              <surname>Mack</surname>
              <given-names>MJ</given-names>
            </name>
          </person-group>
          <article-title>Reliability of risk algorithms in predicting early and late operative outcomes in high-risk patients undergoing aortic valve replacement</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <year>2008</year>
          <volume>135</volume>
          <issue>1</issue>
          <fpage>180</fpage>
          <lpage>187</lpage>
        </element-citation>
      </ref>
      <ref id="B9">
        <label>9</label>
        <mixed-citation>9. Brown JM , O&#8217;Brien SM , Wu C , Sikora JA , Griffith BP , Gammie JS . Isolated aortic valve replacement in North America comprising 108, 687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database . J Thorac Cardiovasc Surg 2009 ; 137 ( 1 ): 82 &#8211; 90 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Brown</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>O&#8217;Brien</surname>
              <given-names>SM</given-names>
            </name>
            <name>
              <surname>Wu</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Sikora</surname>
              <given-names>JA</given-names>
            </name>
            <name>
              <surname>Griffith</surname>
              <given-names>BP</given-names>
            </name>
            <name>
              <surname>Gammie</surname>
              <given-names>JS</given-names>
            </name>
          </person-group>
          <article-title>Isolated aortic valve replacement in North America comprising 108, 687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <year>2009</year>
          <volume>137</volume>
          <issue>1</issue>
          <fpage>82</fpage>
          <lpage>90</lpage>
        </element-citation>
      </ref>
      <ref id="B10">
        <label>10</label>
        <mixed-citation>10. Chukwuemeka A , Borger MA , Ivanov J , Armstrong S , Feindel C , David T . Valve surgery in octogenarians: a safe option with good medium-term results . J Heart Valve Dis 2006 ; 15 ( 2 ): 191 &#8211; 6</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Chukwuemeka</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Borger</surname>
              <given-names>MA</given-names>
            </name>
            <name>
              <surname>Ivanov</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Armstrong</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Feindel</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>David</surname>
              <given-names>T</given-names>
            </name>
          </person-group>
          <article-title>Valve surgery in octogenarians: a safe option with good medium-term results</article-title>
          <source>J Heart Valve Dis</source>
          <year>2006</year>
          <volume>15</volume>
          <issue>2</issue>
          <fpage>191</fpage>
          <lpage>196</lpage>
        </element-citation>
      </ref>
      <ref id="B11">
        <label>11</label>
        <mixed-citation>11. Bouma BJ , van den Brink RBA , van der Meulen JHP , Verheul HA , Cheriex EC , Hamer HP , et al . To operate or not on elderly patients with aortic stenosis: the decision and its consequences . Heart 1999 ; 82 ( 2 ): 143 - 8 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Bouma</surname>
              <given-names>BJ</given-names>
            </name>
            <name>
              <surname>van den Brink</surname>
              <given-names>RBA</given-names>
            </name>
            <name>
              <surname>van der Meulen</surname>
              <given-names>JHP</given-names>
            </name>
            <name>
              <surname>Verheul</surname>
              <given-names>HA</given-names>
            </name>
            <name>
              <surname>Cheriex</surname>
              <given-names>EC</given-names>
            </name>
            <name>
              <surname>Hamer</surname>
              <given-names>HP</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>To operate or not on elderly patients with aortic stenosis: the decision and its consequences</article-title>
          <source>Heart</source>
          <year>1999</year>
          <volume>82</volume>
          <issue>2</issue>
          <fpage>143</fpage>
          <lpage>148</lpage>
        </element-citation>
      </ref>
      <ref id="B12">
        <label>12</label>
        <mixed-citation>12. Lung B , Cachier A , Baron G , Zeitoun DM , Delahaye F , Tornos P , et al . Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery? Eur Heart J 2005 ; 26 ( 24 ): 2714 - 20 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Lung</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Cachier</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Baron</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Zeitoun</surname>
              <given-names>DM</given-names>
            </name>
            <name>
              <surname>Delahaye</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Tornos</surname>
              <given-names>P</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery?</article-title>
          <source>Eur Heart J</source>
          <year>2005</year>
          <volume>26</volume>
          <issue>24</issue>
          <fpage>2714</fpage>
          <lpage>2720</lpage>
        </element-citation>
      </ref>
      <ref id="B13">
        <label>13</label>
        <mixed-citation>13. Varadarajan P , Kapoor N , Bansal RC , Pai RG . Clinical profile and natural history of 453 nonsurgically managed patients with severe aortic stenosis . Ann Thorac Surg 2006 ; 82 ( 6 ): 2111 - 5 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Varadarajan</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Kapoor</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Bansal</surname>
              <given-names>RC</given-names>
            </name>
            <name>
              <surname>Pai</surname>
              <given-names>RG</given-names>
            </name>
          </person-group>
          <article-title>Clinical profile and natural history of 453 nonsurgically managed patients with severe aortic stenosis</article-title>
          <source>Ann Thorac Surg</source>
          <year>2006</year>
          <volume>82</volume>
          <issue>6</issue>
          <fpage>2111</fpage>
          <lpage>2115</lpage>
        </element-citation>
      </ref>
      <ref id="B14">
        <label>14</label>
        <mixed-citation>14. Bach DS , Siao D , Girard SE , Duvernoy C , McCallister BD , Gualano SK . Evaluation of patients with severe symptomatic aortic stenosis who do not undergo aortic valve replacement . Circ Cardiovasc Qual Outcomes . 2009 ; 2 ( 6 ): 533 - 9 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Bach</surname>
              <given-names>DS</given-names>
            </name>
            <name>
              <surname>Siao</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Girard</surname>
              <given-names>SE</given-names>
            </name>
            <name>
              <surname>Duvernoy</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>McCallister</surname>
              <given-names>BD</given-names>
            </name>
            <name>
              <surname>Gualano</surname>
              <given-names>SK</given-names>
            </name>
          </person-group>
          <article-title>Evaluation of patients with severe symptomatic aortic stenosis who do not undergo aortic valve replacement</article-title>
          <source>Circ Cardiovasc Qual Outcomes</source>
          <year>2009</year>
          <volume>2</volume>
          <issue>6</issue>
          <fpage>533</fpage>
          <lpage>539</lpage>
        </element-citation>
      </ref>
      <ref id="B15">
        <label>15</label>
        <mixed-citation>15. Cribier A , Eltchaninoff H , Bash A , Borenstein N , Tron C , Bauer F , et al . Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description . Circulation . 2002 ; 106 ( 24 ): 3006 - 8 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Cribier</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Eltchaninoff</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Bash</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Borenstein</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Tron</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Bauer</surname>
              <given-names>F</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description</article-title>
          <source>Circulation</source>
          <year>2002</year>
          <volume>106</volume>
          <issue>24</issue>
          <fpage>3006</fpage>
          <lpage>3008</lpage>
        </element-citation>
      </ref>
      <ref id="B16">
        <label>16</label>
        <mixed-citation>16. Vahl TP , Kodali SK , Leon MB . Transcatheter Aortic Valve Replacement 2016: A Modern-Day &#8220;Through the Looking-Glass&#8221; Adventure . J Am Coll Cardiol . 2016 ; 67 ( 12 ): 1472 - 87 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Vahl</surname>
              <given-names>TP</given-names>
            </name>
            <name>
              <surname>Kodali</surname>
              <given-names>SK</given-names>
            </name>
            <name>
              <surname>Leon</surname>
              <given-names>MB</given-names>
            </name>
          </person-group>
          <article-title>Transcatheter Aortic Valve Replacement 2016: A Modern-Day &#8220;Through the Looking-Glass&#8221; Adventure</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2016</year>
          <volume>67</volume>
          <issue>12</issue>
          <fpage>1472</fpage>
          <lpage>1487</lpage>
        </element-citation>
      </ref>
      <ref id="B17">
        <label>17</label>
        <mixed-citation>17. Leon MB , Smith CR , Mack M , Miller DC , Morses JW , Svensson LG , et al . Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery . N Engl J Med 2010 ; 363 ( 17 ): 1597 - 607 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Leon</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Smith</surname>
              <given-names>CR</given-names>
            </name>
            <name>
              <surname>Mack</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Miller</surname>
              <given-names>DC</given-names>
            </name>
            <name>
              <surname>Morses</surname>
              <given-names>JW</given-names>
            </name>
            <name>
              <surname>Svensson</surname>
              <given-names>LG</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery</article-title>
          <source>N Engl J Med</source>
          <year>2010</year>
          <volume>363</volume>
          <issue>17</issue>
          <fpage>1597</fpage>
          <lpage>1607</lpage>
        </element-citation>
      </ref>
      <ref id="B18">
        <label>18</label>
        <mixed-citation>18. Smith CR , Leon MB , Mack MJ , Miller DC , Morses JW , Svensson LG , et al . Transcatheter versus surgical aortic-valve replacement in high-risk patients . N Engl J Med 2011 ; 364 ( 23 ): 2187 &#8211; 98 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Smith</surname>
              <given-names>CR</given-names>
            </name>
            <name>
              <surname>Leon</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Mack</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Miller</surname>
              <given-names>DC</given-names>
            </name>
            <name>
              <surname>Morses</surname>
              <given-names>JW</given-names>
            </name>
            <name>
              <surname>Svensson</surname>
              <given-names>LG</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter versus surgical aortic-valve replacement in high-risk patients</article-title>
          <source>N Engl J Med</source>
          <year>2011</year>
          <volume>364</volume>
          <issue>23</issue>
          <fpage>2187</fpage>
          <lpage>2198</lpage>
        </element-citation>
      </ref>
      <ref id="B19">
        <label>19</label>
        <mixed-citation>19. Leon MB , Smith CR , Mack MJ , Makkar RR , Svensson LG , Kodali KS , et al ; PARTNER 2 Investigators . Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients . N Engl J Med . 2016 ; 374 ( 17 ): 1609 - 20 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Leon</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Smith</surname>
              <given-names>CR</given-names>
            </name>
            <name>
              <surname>Mack</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Makkar</surname>
              <given-names>RR</given-names>
            </name>
            <name>
              <surname>Svensson</surname>
              <given-names>LG</given-names>
            </name>
            <name>
              <surname>Kodali</surname>
              <given-names>KS</given-names>
            </name>
            <etal>et al</etal>
            <collab>PARTNER 2 Investigators</collab>
          </person-group>
          <article-title>Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients</article-title>
          <source>N Engl J Med</source>
          <year>2016</year>
          <volume>374</volume>
          <issue>17</issue>
          <fpage>1609</fpage>
          <lpage>1620</lpage>
        </element-citation>
      </ref>
      <ref id="B20">
        <label>20</label>
        <mixed-citation>20. Reardon MJ , Van Mieghem NM , Popma JJ , Kleiman NS , Sondegaard L , Mumtaz M , et al ; SURTAVI Investigators . Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients . N Engl J Med 2017 ; 376 ( 14 ): 1321 - 31 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Reardon</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Van Mieghem</surname>
              <given-names>NM</given-names>
            </name>
            <name>
              <surname>Popma</surname>
              <given-names>JJ</given-names>
            </name>
            <name>
              <surname>Kleiman</surname>
              <given-names>NS</given-names>
            </name>
            <name>
              <surname>Sondegaard</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Mumtaz</surname>
              <given-names>M</given-names>
            </name>
            <etal>et al</etal>
            <collab>SURTAVI Investigators</collab>
          </person-group>
          <article-title>Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients</article-title>
          <source>N Engl J Med</source>
          <year>2017</year>
          <volume>376</volume>
          <issue>14</issue>
          <fpage>1321</fpage>
          <lpage>1331</lpage>
        </element-citation>
      </ref>
      <ref id="B21">
        <label>21</label>
        <mixed-citation>21. Mack MJ , Leon MB , Thourani VH , Makkar R , Kodali SK , Russo M , et al ; PARTNER 3 Investigators . Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients . N Engl J Med . 2019 May 2 ; 380 ( 18 ): 1695 - 1705 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Mack</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Leon</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Thourani</surname>
              <given-names>VH</given-names>
            </name>
            <name>
              <surname>Makkar</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Kodali</surname>
              <given-names>SK</given-names>
            </name>
            <name>
              <surname>Russo</surname>
              <given-names>M</given-names>
            </name>
            <etal>et al</etal>
            <collab>PARTNER 3 Investigators</collab>
          </person-group>
          <article-title>Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients</article-title>
          <source>N Engl J Med</source>
          <year>2019</year>
          <month>05</month>
          <day>2</day>
          <volume>380</volume>
          <issue>18</issue>
          <fpage>1695</fpage>
          <lpage>1705</lpage>
        </element-citation>
      </ref>
      <ref id="B22">
        <label>22</label>
        <mixed-citation>22. Popma JJ , Deeb GM , Yakubov SJ , Mumtaz M , Gada H , O&#8217;Hair D , et al ; Evolut Low Risk Trial Investigators . Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients . N Engl J Med . 2019 May 2 ; 380 ( 18 ): 1706 - 1715 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Popma</surname>
              <given-names>JJ</given-names>
            </name>
            <name>
              <surname>Deeb</surname>
              <given-names>GM</given-names>
            </name>
            <name>
              <surname>Yakubov</surname>
              <given-names>SJ</given-names>
            </name>
            <name>
              <surname>Mumtaz</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Gada</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>O&#8217;Hair</surname>
              <given-names>D</given-names>
            </name>
            <etal>et al</etal>
            <collab>Evolut Low Risk Trial Investigators</collab>
          </person-group>
          <article-title>Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients</article-title>
          <source>N Engl J Med</source>
          <year>2019</year>
          <month>05</month>
          <day>2</day>
          <volume>380</volume>
          <issue>18</issue>
          <fpage>1706</fpage>
          <lpage>1715</lpage>
        </element-citation>
      </ref>
      <ref id="B23">
        <label>23</label>
        <mixed-citation>23. Waksman R , Rogers T , Torguson R , Gordon P , Ehsan A , Wilson SR , et al . Transcatheter aortic valve replacement in low&#8208;risk patients with symptomatic severe aortic stenosis . J Am Coll Cardiol . 2018 ; 72 ( 18 ): 2095 &#8208; 2105 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Waksman</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Rogers</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Torguson</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Gordon</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Ehsan</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Wilson</surname>
              <given-names>SR</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter aortic valve replacement in low&#8208;risk patients with symptomatic severe aortic stenosis</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2018</year>
          <volume>72</volume>
          <issue>18</issue>
          <fpage>2095</fpage>
          <lpage>2105</lpage>
        </element-citation>
      </ref>
      <ref id="B24">
        <label>24</label>
        <mixed-citation>24. Thyregod HGH , Ihlemann N , J&#248;rgensen TH , Nissen H , Kjeldsen BO , Petursson P , et al . Five&#8208;year clinical and echocardiographic outcomes from the NOTION randomized clinical trial in patients at lower surgical risk . Circulation . 2019 ; 139 ( 24 ): 2714&#8208;2723 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Thyregod</surname>
              <given-names>HGH</given-names>
            </name>
            <name>
              <surname>Ihlemann</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>J&#248;rgensen</surname>
              <given-names>TH</given-names>
            </name>
            <name>
              <surname>Nissen</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Kjeldsen</surname>
              <given-names>BO</given-names>
            </name>
            <name>
              <surname>Petursson</surname>
              <given-names>P</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Five&#8208;year clinical and echocardiographic outcomes from the NOTION randomized clinical trial in patients at lower surgical risk</article-title>
          <source>Circulation</source>
          <year>2019</year>
          <volume>139</volume>
          <issue>24</issue>
          <fpage>2714</fpage>
          <lpage>2723</lpage>
        </element-citation>
      </ref>
      <ref id="B25">
        <label>25</label>
        <mixed-citation>25. O&#8217;Brien KD , Shavelle DM , Caulfield MT , McDonald TO , Lewis KO , Otto CM , et al . Association of angiotensin-converting enzyme with low-density lipoprotein in aortic valvular lesions and in human plasma . Circulation 2002 ; 106 ( 17 ): 2224 &#8211; 30 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>O&#8217;Brien</surname>
              <given-names>KD</given-names>
            </name>
            <name>
              <surname>Shavelle</surname>
              <given-names>DM</given-names>
            </name>
            <name>
              <surname>Caulfield</surname>
              <given-names>MT</given-names>
            </name>
            <name>
              <surname>McDonald</surname>
              <given-names>TO</given-names>
            </name>
            <name>
              <surname>Lewis</surname>
              <given-names>KO</given-names>
            </name>
            <name>
              <surname>Otto</surname>
              <given-names>CM</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Association of angiotensin-converting enzyme with low-density lipoprotein in aortic valvular lesions and in human plasma</article-title>
          <source>Circulation</source>
          <year>2002</year>
          <volume>106</volume>
          <issue>17</issue>
          <fpage>2224</fpage>
          <lpage>2230</lpage>
        </element-citation>
      </ref>
      <ref id="B26">
        <label>26</label>
        <mixed-citation>26. Mohler ER , Gannon F , Reynolds C , Zimmerman R , Keane MG , Kaplan FS . Bone formation and inflammation in cardiac valves . Circulation 2001 ; 103 ( 11 ): 1522 &#8211; 8 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Mohler</surname>
              <given-names>ER</given-names>
            </name>
            <name>
              <surname>Gannon</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Reynolds</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Zimmerman</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Keane</surname>
              <given-names>MG</given-names>
            </name>
            <name>
              <surname>Kaplan</surname>
              <given-names>FS</given-names>
            </name>
          </person-group>
          <article-title>Bone formation and inflammation in cardiac valves</article-title>
          <source>Circulation</source>
          <year>2001</year>
          <volume>103</volume>
          <issue>11</issue>
          <fpage>1522</fpage>
          <lpage>1528</lpage>
        </element-citation>
      </ref>
      <ref id="B27">
        <label>27</label>
        <mixed-citation>27. Stewart BF , Siscovick D , Lind BK , Gardin JM , Gottdiener JM , Smith VE , et al . Clinical factors associated with calcific aortic valve disease: cardiovascular health study . J Am Coll Cardiol 1997 ; 29 ( 3 ): 630 &#8211; 4 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Stewart</surname>
              <given-names>BF</given-names>
            </name>
            <name>
              <surname>Siscovick</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Lind</surname>
              <given-names>BK</given-names>
            </name>
            <name>
              <surname>Gardin</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Gottdiener</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Smith</surname>
              <given-names>VE</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Clinical factors associated with calcific aortic valve disease: cardiovascular health study</article-title>
          <source>J Am Coll Cardiol</source>
          <year>1997</year>
          <volume>29</volume>
          <issue>3</issue>
          <fpage>630</fpage>
          <lpage>634</lpage>
        </element-citation>
      </ref>
      <ref id="B28">
        <label>28</label>
        <mixed-citation>28. Rajamannan NM . Low-density lipoprotein and aortic stenosis . Heart 2008 ; 94 ( 9 ): 1111 &#8211; 2 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Rajamannan</surname>
              <given-names>NM</given-names>
            </name>
          </person-group>
          <article-title>Low-density lipoprotein and aortic stenosis</article-title>
          <source>Heart</source>
          <year>2008</year>
          <volume>94</volume>
          <issue>9</issue>
          <fpage>1111</fpage>
          <lpage>1112</lpage>
        </element-citation>
      </ref>
      <ref id="B29">
        <label>29</label>
        <mixed-citation>29. Mylotte D , Lefevre T , S&#248;ndergaard L , Watanabe Y , Modine T , Dvir D , et al . Transcatheter aortic valve replacement in bicuspid aortic valve disease . J Am Coll Cardiol . 2014 ; 64 ( 22 ): 2330 - 9 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Mylotte</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Lefevre</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>S&#248;ndergaard</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Watanabe</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Modine</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Dvir</surname>
              <given-names>D</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter aortic valve replacement in bicuspid aortic valve disease</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2014</year>
          <volume>64</volume>
          <issue>22</issue>
          <fpage>2330</fpage>
          <lpage>2339</lpage>
        </element-citation>
      </ref>
      <ref id="B30">
        <label>30</label>
        <mixed-citation>30. Reddy G , Wang Z , Nishimura RA , Greason KL , Yoon SH , Makkar RR , et al . Transcatheter aortic valve replacement for stenotic bicuspid aortic valves: Systematic review and meta analyses of observational studies . Catheter Cardiovasc Interv 2018 ; 91 ( 5 ): 975 - 83 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Reddy</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Wang</surname>
              <given-names>Z</given-names>
            </name>
            <name>
              <surname>Nishimura</surname>
              <given-names>RA</given-names>
            </name>
            <name>
              <surname>Greason</surname>
              <given-names>KL</given-names>
            </name>
            <name>
              <surname>Yoon</surname>
              <given-names>SH</given-names>
            </name>
            <name>
              <surname>Makkar</surname>
              <given-names>RR</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter aortic valve replacement for stenotic bicuspid aortic valves: Systematic review and meta analyses of observational studies</article-title>
          <source>Catheter Cardiovasc Interv</source>
          <year>2018</year>
          <volume>91</volume>
          <issue>5</issue>
          <fpage>975</fpage>
          <lpage>983</lpage>
        </element-citation>
      </ref>
      <ref id="B31">
        <label>31</label>
        <mixed-citation>31. Grover FL , Vemulapalli S , Carroll JD , Edwards FH , Mack MJ , Tourani VH , et al . 2016 Annual Report of The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry . J Am Coll Cardiol 2017 ; 69 ( 10 ): 1215 - 30 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Grover</surname>
              <given-names>FL</given-names>
            </name>
            <name>
              <surname>Vemulapalli</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Carroll</surname>
              <given-names>JD</given-names>
            </name>
            <name>
              <surname>Edwards</surname>
              <given-names>FH</given-names>
            </name>
            <name>
              <surname>Mack</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Tourani</surname>
              <given-names>VH</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>2016 Annual Report of The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2017</year>
          <volume>69</volume>
          <issue>10</issue>
          <fpage>1215</fpage>
          <lpage>1230</lpage>
        </element-citation>
      </ref>
      <ref id="B32">
        <label>32</label>
        <mixed-citation>32. Roberts WC , Ko JM . Frequency by decades of unicuspid, bicuspid, and tricuspid aortic valves in adults having isolated aortic valve replacement for aortic stenosis, with or without associated aortic regurgitation . Circulation 2005 ; 111 ( 7 ): 920 &#8211; 5 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Roberts</surname>
              <given-names>WC</given-names>
            </name>
            <name>
              <surname>Ko</surname>
              <given-names>JM</given-names>
            </name>
          </person-group>
          <article-title>Frequency by decades of unicuspid, bicuspid, and tricuspid aortic valves in adults having isolated aortic valve replacement for aortic stenosis, with or without associated aortic regurgitation</article-title>
          <source>Circulation</source>
          <year>2005</year>
          <volume>111</volume>
          <issue>7</issue>
          <fpage>920</fpage>
          <lpage>925</lpage>
        </element-citation>
      </ref>
      <ref id="B33">
        <label>33</label>
        <mixed-citation>33. Webb JG , Mack MJ , White JM , Dvir D , Blanke P , Herrmann HC , et al . Transcatheter Aortic Valve Implantation Within Degenerated Aortic Surgical Bioprostheses: PARTNER 2 Valve-in-Valve Registry . J Am Coll Cardiol 2017 ; 69 ( 18 ): 2253 - 62 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Webb</surname>
              <given-names>JG</given-names>
            </name>
            <name>
              <surname>Mack</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>White</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Dvir</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Blanke</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Herrmann</surname>
              <given-names>HC</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter Aortic Valve Implantation Within Degenerated Aortic Surgical Bioprostheses: PARTNER 2 Valve-in-Valve Registry</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2017</year>
          <volume>69</volume>
          <issue>18</issue>
          <fpage>2253</fpage>
          <lpage>2262</lpage>
        </element-citation>
      </ref>
      <ref id="B34">
        <label>34</label>
        <mixed-citation>34. Deeb GM , Chetcuti SJ , Reardon MJ , Patel HJ , Grossman PM , Schreiber T , et al . 1-Year Results in Patients Undergoing Transcatheter Aortic Valve Replacement With Failed Surgical Bioprostheses . JACC Cardiovasc Interv 2017 ; 10 ( 10 ): 1034 - 44 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Deeb</surname>
              <given-names>GM</given-names>
            </name>
            <name>
              <surname>Chetcuti</surname>
              <given-names>SJ</given-names>
            </name>
            <name>
              <surname>Reardon</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Patel</surname>
              <given-names>HJ</given-names>
            </name>
            <name>
              <surname>Grossman</surname>
              <given-names>PM</given-names>
            </name>
            <name>
              <surname>Schreiber</surname>
              <given-names>T</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>1-Year Results in Patients Undergoing Transcatheter Aortic Valve Replacement With Failed Surgical Bioprostheses</article-title>
          <source>JACC Cardiovasc Interv</source>
          <year>2017</year>
          <volume>10</volume>
          <issue>10</issue>
          <fpage>1034</fpage>
          <lpage>1044</lpage>
        </element-citation>
      </ref>
      <ref id="B35">
        <label>35</label>
        <mixed-citation>35. Tam DY , Vo TX , Wijeysundera HC , Dvir D , Friedrich JO , Fremes SE ; Transcatheter valve-in-valve versus redo surgical aortic valve replacement for the treatment of degenerated bioprosthetic aortic valve: A systematic review and meta-analysis . Catheter Cardiovasc Interv . 2018 ; 92 ( 7 ): 1404 - 11 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Tam</surname>
              <given-names>DY</given-names>
            </name>
            <name>
              <surname>Vo</surname>
              <given-names>TX</given-names>
            </name>
            <name>
              <surname>Wijeysundera</surname>
              <given-names>HC</given-names>
            </name>
            <name>
              <surname>Dvir</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Friedrich</surname>
              <given-names>JO</given-names>
            </name>
            <name>
              <surname>Fremes</surname>
              <given-names>SE</given-names>
            </name>
          </person-group>
          <article-title>Transcatheter valve-in-valve versus redo surgical aortic valve replacement for the treatment of degenerated bioprosthetic aortic valve: A systematic review and meta-analysis</article-title>
          <source>Catheter Cardiovasc Interv</source>
          <year>2018</year>
          <volume>92</volume>
          <issue>7</issue>
          <fpage>1404</fpage>
          <lpage>1411</lpage>
        </element-citation>
      </ref>
      <ref id="B36">
        <label>36</label>
        <mixed-citation>36. Gozdek M , Raffa GM , Suwalski P , Kolodziejczak M , Anisimowicz , Kubica J , et al . Comparative performance of transcatheter aortic valve-in-valve implantation versus conventional surgical redo aortic valve replacement in patients with degenerated aortic valve bioprostheses: systematic review and meta-analysis . Eur J Cardio-Thoracic Surg . 2018 ; 53 ( 3 ): 495 - 504 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Gozdek</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Raffa</surname>
              <given-names>GM</given-names>
            </name>
            <name>
              <surname>Suwalski</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Kolodziejczak</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Anisimowicz</surname>
            </name>
            <name>
              <surname>Kubica</surname>
              <given-names>J</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Comparative performance of transcatheter aortic valve-in-valve implantation versus conventional surgical redo aortic valve replacement in patients with degenerated aortic valve bioprostheses: systematic review and meta-analysis</article-title>
          <source>Eur J Cardio-Thoracic Surg</source>
          <year>2018</year>
          <volume>53</volume>
          <issue>3</issue>
          <fpage>495</fpage>
          <lpage>504</lpage>
        </element-citation>
      </ref>
      <ref id="B37">
        <label>37</label>
        <mixed-citation>37. Nalluri N , Atti V , Munir AB , Karam B , Patel NJ , Kumar V , et al . Valve in valve transcatheter aortic valve implantation (ViV-TAVI) versus redo-Surgical aortic valve replacement (redo-SAVR): A systematic review and meta-analysis . J Interv Cardiol . 2018 ; 31 ( 5 ): 661 - 71 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Nalluri</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Atti</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Munir</surname>
              <given-names>AB</given-names>
            </name>
            <name>
              <surname>Karam</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Patel</surname>
              <given-names>NJ</given-names>
            </name>
            <name>
              <surname>Kumar</surname>
              <given-names>V</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Valve in valve transcatheter aortic valve implantation (ViV-TAVI) versus redo-Surgical aortic valve replacement (redo-SAVR): A systematic review and meta-analysis</article-title>
          <source>J Interv Cardiol</source>
          <year>2018</year>
          <volume>31</volume>
          <issue>5</issue>
          <fpage>661</fpage>
          <lpage>671</lpage>
        </element-citation>
      </ref>
      <ref id="B38">
        <label>38</label>
        <mixed-citation>38. Takagi H , Mitta S , Ando T . Meta-analysis of Valve-in-Valve Transcatheter versus Redo Surgical Aortic Valve Replacement . Thorac Cardiovasc Surg . August 2018 ; 67 ( 4 ): 243 - 50</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Takagi</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Mitta</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Ando</surname>
              <given-names>T</given-names>
            </name>
          </person-group>
          <article-title>Meta-analysis of Valve-in-Valve Transcatheter versus Redo Surgical Aortic Valve Replacement</article-title>
          <source>Thorac Cardiovasc Surg</source>
          <month>08</month>
          <year>2018</year>
          <volume>67</volume>
          <issue>4</issue>
          <fpage>243</fpage>
          <lpage>250</lpage>
        </element-citation>
      </ref>
      <ref id="B39">
        <label>39</label>
        <mixed-citation>39. Neupane S , Singh H , L&#228;mmer J , Othman H , Yamasaki H , Rosman HS , et al . Meta-Analysis of Transcatheter Valvein- Valve Implantation Versus Redo Aortic Valve Surgery for Bioprosthetic Aortic Valve Dysfunction . Am J Cardiol . 2018 ; 121 ( 12 ): 1593 - 1600 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Neupane</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Singh</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>L&#228;mmer</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Othman</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Yamasaki</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Rosman</surname>
              <given-names>HS</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Meta-Analysis of Transcatheter Valvein- Valve Implantation Versus Redo Aortic Valve Surgery for Bioprosthetic Aortic Valve Dysfunction</article-title>
          <source>Am J Cardiol</source>
          <year>2018</year>
          <volume>121</volume>
          <issue>12</issue>
          <fpage>1593</fpage>
          <lpage>1600</lpage>
        </element-citation>
      </ref>
      <ref id="B40">
        <label>40</label>
        <mixed-citation>40. Dvir D , Webb JG , Bleiziffer S , Pasic M , Waksman R , Kodali S , et al . Transcatheter aortic valve implantation in failed bioprosthetic surgical valves . JAMA . 2014 ; 312 ( 2 ): 162 - 170 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Dvir</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Webb</surname>
              <given-names>JG</given-names>
            </name>
            <name>
              <surname>Bleiziffer</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Pasic</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Waksman</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Kodali</surname>
              <given-names>S</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter aortic valve implantation in failed bioprosthetic surgical valves</article-title>
          <source>JAMA</source>
          <year>2014</year>
          <volume>312</volume>
          <issue>2</issue>
          <fpage>162</fpage>
          <lpage>170</lpage>
        </element-citation>
      </ref>
      <ref id="B41">
        <label>41</label>
        <mixed-citation>41. Barbanti M . Avoiding Coronary Occlusion And Root Rupture In TAVI &#8211; The Role Of Pre-procedural Imaging And Prosthesis Selection . Interv Cardio . 2015 ; 10 ( 2 ): 94 - 7 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Barbanti</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Avoiding Coronary Occlusion And Root Rupture In TAVI &#8211; The Role Of Pre-procedural Imaging And Prosthesis Selection</article-title>
          <source>Interv Cardio</source>
          <year>2015</year>
          <volume>10</volume>
          <issue>2</issue>
          <fpage>94</fpage>
          <lpage>97</lpage>
        </element-citation>
      </ref>
      <ref id="B42">
        <label>42</label>
        <mixed-citation>42. Allen KB , Chhatriwalla AK , Cohen DJ , Saxon JT , Aggarwal S , Hart A , Baron S , Davis JR , Pak AF , Dvir D , Borkon AM . Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation . Ann Thorac Surg . 2017 Nov ; 104 ( 5 ): 1501 - 8</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Allen</surname>
              <given-names>KB</given-names>
            </name>
            <name>
              <surname>Chhatriwalla</surname>
              <given-names>AK</given-names>
            </name>
            <name>
              <surname>Cohen</surname>
              <given-names>DJ</given-names>
            </name>
            <name>
              <surname>Saxon</surname>
              <given-names>JT</given-names>
            </name>
            <name>
              <surname>Aggarwal</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Hart</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Baron</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Davis</surname>
              <given-names>JR</given-names>
            </name>
            <name>
              <surname>Pak</surname>
              <given-names>AF</given-names>
            </name>
            <name>
              <surname>Dvir</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Borkon</surname>
              <given-names>AM</given-names>
            </name>
          </person-group>
          <article-title>Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation</article-title>
          <source>Ann Thorac Surg</source>
          <year>2017</year>
          <month>11</month>
          <volume>104</volume>
          <issue>5</issue>
          <fpage>1501</fpage>
          <lpage>1508</lpage>
        </element-citation>
      </ref>
      <ref id="B43">
        <label>43</label>
        <mixed-citation>43. Baumgartner H , Falk V , Bax JJ , Bonis M , Hamm C , Holm PJ , et al . ESC/EACTS Guidelines for the management of valvular heart disease: The Task Force for the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for CardioThoracic Surgery (EACTS) . Eur Heart J . 2017 Sep 21 ; 38 ( 36 ): 2739 - 91 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Baumgartner</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Falk</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Bax</surname>
              <given-names>JJ</given-names>
            </name>
            <name>
              <surname>Bonis</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Hamm</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Holm</surname>
              <given-names>PJ</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>ESC/EACTS Guidelines for the management of valvular heart disease: The Task Force for the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for CardioThoracic Surgery (EACTS)</article-title>
          <source>Eur Heart J</source>
          <year>2017</year>
          <month>09</month>
          <day>21</day>
          <volume>38</volume>
          <issue>36</issue>
          <fpage>2739</fpage>
          <lpage>2791</lpage>
        </element-citation>
      </ref>
      <ref id="B44">
        <label>44</label>
        <mixed-citation>44. Rosenhek R , Binder T , Porenta G , Lang I , Christ G , Schemper M , et al . Predictors of outcome in severe, asymptomatic aortic stenosis . N Engl J Med 2000 ; 343 ( 9 ): 611 &#8211; 7 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Rosenhek</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Binder</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Porenta</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Lang</surname>
              <given-names>I</given-names>
            </name>
            <name>
              <surname>Christ</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Schemper</surname>
              <given-names>M</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Predictors of outcome in severe, asymptomatic aortic stenosis</article-title>
          <source>N Engl J Med</source>
          <year>2000</year>
          <volume>343</volume>
          <issue>9</issue>
          <fpage>611</fpage>
          <lpage>617</lpage>
        </element-citation>
      </ref>
      <ref id="B45">
        <label>45</label>
        <mixed-citation>45. Stoica SC , Cafferty F , Kitcat J , Baskett RJ , Goddard M , Sharples LD , et al . Octogenarians undergoing cardiac surgery outlive their peers: a case for early referral . Heart 2006 ; 92 ( 4 ): 503 &#8211; 6 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Stoica</surname>
              <given-names>SC</given-names>
            </name>
            <name>
              <surname>Cafferty</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Kitcat</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Baskett</surname>
              <given-names>RJ</given-names>
            </name>
            <name>
              <surname>Goddard</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Sharples</surname>
              <given-names>LD</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Octogenarians undergoing cardiac surgery outlive their peers: a case for early referral</article-title>
          <source>Heart</source>
          <year>2006</year>
          <volume>92</volume>
          <issue>4</issue>
          <fpage>503</fpage>
          <lpage>506</lpage>
        </element-citation>
      </ref>
      <ref id="B46">
        <label>46</label>
        <mixed-citation>46. Thomas M , Schymik G , Walther T , Himbert D , Lef&#232;vre T , Treede H , et al . Thirty-day results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: a European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve . Circulation 2010 ; 122 ( 1 ): 62 &#8211; 9 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Thomas</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Schymik</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Walther</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Himbert</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Lef&#232;vre</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Treede</surname>
              <given-names>H</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Thirty-day results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: a European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve</article-title>
          <source>Circulation</source>
          <year>2010</year>
          <volume>122</volume>
          <issue>1</issue>
          <fpage>62</fpage>
          <lpage>69</lpage>
        </element-citation>
      </ref>
      <ref id="B47">
        <label>47</label>
        <mixed-citation>47. Thomas M , Schymik G , Walther T , Himbert D , Lef&#232;vre T , Treede H , et al . One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve . Circulation 2011 ; 124 ( 4 ): 425 &#8211; 33 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Thomas</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Schymik</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Walther</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Himbert</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Lef&#232;vre</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Treede</surname>
              <given-names>H</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve</article-title>
          <source>Circulation</source>
          <year>2011</year>
          <volume>124</volume>
          <issue>4</issue>
          <fpage>425</fpage>
          <lpage>433</lpage>
        </element-citation>
      </ref>
      <ref id="B48">
        <label>48</label>
        <mixed-citation>48. Zahn R , Gerckens U , Grube E , Linke A , Sievert H , Eggebrecht H , et al . Transcatheter aortic valve implantation: first results from a multi-centre real-world registry . Eur Heart J 2011 ; 32 ( 2 ): 198 &#8211; 204 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Zahn</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Gerckens</surname>
              <given-names>U</given-names>
            </name>
            <name>
              <surname>Grube</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Linke</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Sievert</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Eggebrecht</surname>
              <given-names>H</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter aortic valve implantation: first results from a multi-centre real-world registry</article-title>
          <source>Eur Heart J</source>
          <year>2011</year>
          <volume>32</volume>
          <issue>2</issue>
          <fpage>198</fpage>
          <lpage>204</lpage>
        </element-citation>
      </ref>
      <ref id="B49">
        <label>49</label>
        <mixed-citation>49. Webb J , Gerosa G , Lef&#232;vre T , Leipsic J , Spence M , Thomas M , et al . Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve . J Am Coll Cardiol 2014 ; 64 ( 21 ): 2235 &#8211; 43 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Webb</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Gerosa</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Lef&#232;vre</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Leipsic</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Spence</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Thomas</surname>
              <given-names>M</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2014</year>
          <volume>64</volume>
          <issue>21</issue>
          <fpage>2235</fpage>
          <lpage>2243</lpage>
        </element-citation>
      </ref>
      <ref id="B50">
        <label>50</label>
        <mixed-citation>50. Herrmann HC , Thourani VH , Kodali SK , Makkar RR , Szeto WY , Anwaruddin S , et al . One-year clinical outcomes with SAPIEN 3 transcatheter aortic valve replacement in high-risk and inoperable patients with severe aortic stenosis . Circulation 2016 ; 134 ( 2 ): 130 &#8211; 40 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Herrmann</surname>
              <given-names>HC</given-names>
            </name>
            <name>
              <surname>Thourani</surname>
              <given-names>VH</given-names>
            </name>
            <name>
              <surname>Kodali</surname>
              <given-names>SK</given-names>
            </name>
            <name>
              <surname>Makkar</surname>
              <given-names>RR</given-names>
            </name>
            <name>
              <surname>Szeto</surname>
              <given-names>WY</given-names>
            </name>
            <name>
              <surname>Anwaruddin</surname>
              <given-names>S</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>One-year clinical outcomes with SAPIEN 3 transcatheter aortic valve replacement in high-risk and inoperable patients with severe aortic stenosis</article-title>
          <source>Circulation</source>
          <year>2016</year>
          <volume>134</volume>
          <issue>2</issue>
          <fpage>130</fpage>
          <lpage>140</lpage>
        </element-citation>
      </ref>
      <ref id="B51">
        <label>51</label>
        <mixed-citation>51. Buellesfeld L , Gerckens U , Schuler G , Bonan R , Kovac J , Serruys PW , et al . 2-year follow-up of patients undergoing transcatheter aortic valve implantation using a self-expanding valve prosthesis . J Am Coll Cardiol 2011 ; 57 ( 16 ): 1650 &#8211; 7 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Buellesfeld</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Gerckens</surname>
              <given-names>U</given-names>
            </name>
            <name>
              <surname>Schuler</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Bonan</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Kovac</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Serruys</surname>
              <given-names>PW</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>2-year follow-up of patients undergoing transcatheter aortic valve implantation using a self-expanding valve prosthesis</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2011</year>
          <volume>57</volume>
          <issue>16</issue>
          <fpage>1650</fpage>
          <lpage>1657</lpage>
        </element-citation>
      </ref>
      <ref id="B52">
        <label>52</label>
        <mixed-citation>52. Reardon MJ , Adams DH , Kleiman NS , Yakubov SJ , Coselli JS , Deeb JB , et al . 2-year outcomes in patients undergoing surgical or self-expanding transcatheter aortic valve replacement . J Am Coll Cardiol 2015 ; 66 ( 2 ): 113 &#8211; 21 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Reardon</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Adams</surname>
              <given-names>DH</given-names>
            </name>
            <name>
              <surname>Kleiman</surname>
              <given-names>NS</given-names>
            </name>
            <name>
              <surname>Yakubov</surname>
              <given-names>SJ</given-names>
            </name>
            <name>
              <surname>Coselli</surname>
              <given-names>JS</given-names>
            </name>
            <name>
              <surname>Deeb</surname>
              <given-names>JB</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>2-year outcomes in patients undergoing surgical or self-expanding transcatheter aortic valve replacement</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2015</year>
          <volume>66</volume>
          <issue>2</issue>
          <fpage>113</fpage>
          <lpage>121</lpage>
        </element-citation>
      </ref>
      <ref id="B53">
        <label>53</label>
        <mixed-citation>53. Holmes DR Jr , Brennan JM , Rumsfeld JS , Dai D , O&#8217;Brien SM , Vemulapalli S , et al . Clinical outcomes at 1 year following transcatheter aortic valve replacement . JAMA 2015 ; 313 ( 10 ): 1019 &#8211; 28 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Holmes</surname>
              <given-names>DR</given-names>
              <suffix>Jr</suffix>
            </name>
            <name>
              <surname>Brennan</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Rumsfeld</surname>
              <given-names>JS</given-names>
            </name>
            <name>
              <surname>Dai</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>O&#8217;Brien</surname>
              <given-names>SM</given-names>
            </name>
            <name>
              <surname>Vemulapalli</surname>
              <given-names>S</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Clinical outcomes at 1 year following transcatheter aortic valve replacement</article-title>
          <source>JAMA</source>
          <year>2015</year>
          <volume>313</volume>
          <issue>10</issue>
          <fpage>1019</fpage>
          <lpage>1028</lpage>
        </element-citation>
      </ref>
      <ref id="B54">
        <label>54</label>
        <mixed-citation>54. Gurvitch R , Wood DA , Tay EL , Leipsic J , Ye J , Lichtenstein SV , et al . Transcatheter aortic valve implantation: durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort . Circulation 2010 ; 122 ( 13 ): 1319 &#8211; 27 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Gurvitch</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Wood</surname>
              <given-names>DA</given-names>
            </name>
            <name>
              <surname>Tay</surname>
              <given-names>EL</given-names>
            </name>
            <name>
              <surname>Leipsic</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Ye</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Lichtenstein</surname>
              <given-names>SV</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter aortic valve implantation: durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort</article-title>
          <source>Circulation</source>
          <year>2010</year>
          <volume>122</volume>
          <issue>13</issue>
          <fpage>1319</fpage>
          <lpage>1327</lpage>
        </element-citation>
      </ref>
      <ref id="B55">
        <label>55</label>
        <mixed-citation>55. Mack MJ , Leon MB , Smith CR , Miller DC , Moses JW , Tuzcu EM , et al . PARTNER 1 trial investigators . 5-year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial . Lancet 2015 ; 385 ( 9986 ): 2477 &#8211; 8 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Mack</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Leon</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Smith</surname>
              <given-names>CR</given-names>
            </name>
            <name>
              <surname>Miller</surname>
              <given-names>DC</given-names>
            </name>
            <name>
              <surname>Moses</surname>
              <given-names>JW</given-names>
            </name>
            <name>
              <surname>Tuzcu</surname>
              <given-names>EM</given-names>
            </name>
            <etal>et al</etal>
            <collab>PARTNER 1 trial investigators</collab>
          </person-group>
          <article-title>5-year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial</article-title>
          <source>Lancet</source>
          <year>2015</year>
          <volume>385</volume>
          <issue>9986</issue>
          <fpage>2477</fpage>
          <lpage>2478</lpage>
        </element-citation>
      </ref>
      <ref id="B56">
        <label>56</label>
        <mixed-citation>56. Siontis GCM , Praz F , Pilgrim T , Mavridis D , Verma S , Salanti G , et al . Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of severe aortic stenosis: a meta-analysis of randomized trials . Eur Heart J 2016 ; 37 ( 47 ): 3503 &#8211; 12 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Siontis</surname>
              <given-names>GCM</given-names>
            </name>
            <name>
              <surname>Praz</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Pilgrim</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Mavridis</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Verma</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Salanti</surname>
              <given-names>G</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of severe aortic stenosis: a meta-analysis of randomized trials</article-title>
          <source>Eur Heart J</source>
          <year>2016</year>
          <volume>37</volume>
          <issue>47</issue>
          <fpage>3503</fpage>
          <lpage>3512</lpage>
        </element-citation>
      </ref>
      <ref id="B57">
        <label>57</label>
        <mixed-citation>57. Rahhab Z , El Faquir N , Tchetche D , et al . Expanding the indications for transcatheter aortic valve implantation . Nat Rev Cardiol . 2020 Feb ; 17 ( 2 ): 75 - 84 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Rahhab</surname>
              <given-names>Z</given-names>
            </name>
            <name>
              <surname>El Faquir</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Tchetche</surname>
              <given-names>D</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Expanding the indications for transcatheter aortic valve implantation</article-title>
          <source>Nat Rev Cardiol</source>
          <year>2020</year>
          <month>02</month>
          <volume>17</volume>
          <issue>2</issue>
          <fpage>75</fpage>
          <lpage>84</lpage>
        </element-citation>
      </ref>
      <ref id="B58">
        <label>58</label>
        <mixed-citation>58. Barbanti M , Webb JG , Gilard M , Capodanno D , Tamburino C . Transcatheter aortic valve implantation in 2017: state of the art . EuroIntervention . 2017 : 24 ; 13 ( AA ): AA11 - AA21 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Barbanti</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Webb</surname>
              <given-names>JG</given-names>
            </name>
            <name>
              <surname>Gilard</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Capodanno</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Tamburino</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>Transcatheter aortic valve implantation in 2017: state of the art</article-title>
          <source>EuroIntervention</source>
          <year>2017</year>
          <volume>24</volume>
          <issue>13</issue>
          <comment>AA</comment>
          <fpage>AA11</fpage>
          <lpage>AA21</lpage>
        </element-citation>
      </ref>
      <ref id="B59">
        <label>59</label>
        <mixed-citation>59. Pascual I , Carro A , Avanzas P , Vaquero DH , D&#237;az R , Rozado J , et al . Vascular approaches for transcatheter aortic valve implantation . J Thorac Dis . 2017 ; 9 ( Suppl 6 ): S478 - 87 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Pascual</surname>
              <given-names>I</given-names>
            </name>
            <name>
              <surname>Carro</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Avanzas</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Vaquero</surname>
              <given-names>DH</given-names>
            </name>
            <name>
              <surname>D&#237;az</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Rozado</surname>
              <given-names>J</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Vascular approaches for transcatheter aortic valve implantation</article-title>
          <source>J Thorac Dis</source>
          <year>2017</year>
          <volume>9</volume>
          <supplement>Suppl 6</supplement>
          <fpage>S478</fpage>
          <lpage>S487</lpage>
        </element-citation>
      </ref>
      <ref id="B60">
        <label>60</label>
        <mixed-citation>60. Barbanti M , Buccheri S , Rod&#233;s-Cabau J , Gulino S , G&#233;n&#233;reux P , Pilato G , et al . Transcatheter aortic valve replacement with new-generation devices: A systematic review and meta-analysis . Int J Cardiol . 2017 ; 15 ; 245 : 83-89</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Barbanti</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Buccheri</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Rod&#233;s-Cabau</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Gulino</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>G&#233;n&#233;reux</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Pilato</surname>
              <given-names>G</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter aortic valve replacement with new-generation devices: A systematic review and meta-analysis</article-title>
          <source>Int J Cardiol</source>
          <year>2017</year>
          <volume>15</volume>
          <issue>245</issue>
          <fpage>83</fpage>
          <lpage>89</lpage>
        </element-citation>
      </ref>
      <ref id="B61">
        <label>61</label>
        <mixed-citation>61. Regueiro A , Linke A , Latib A , Ihlemann N , Urena M , Walther T , et al . Association Between Transcatheter Aortic Valve Replacement and Subsequent Infective Endocarditis and In-Hospital Death . JAMA . 2016 ; 316 ( 10 ): 1083 - 92 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Regueiro</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Linke</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Latib</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Ihlemann</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Urena</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Walther</surname>
              <given-names>T</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Association Between Transcatheter Aortic Valve Replacement and Subsequent Infective Endocarditis and In-Hospital Death</article-title>
          <source>JAMA</source>
          <year>2016</year>
          <volume>316</volume>
          <issue>10</issue>
          <fpage>1083</fpage>
          <lpage>1092</lpage>
        </element-citation>
      </ref>
      <ref id="B62">
        <label>62</label>
        <mixed-citation>62. Barbanti M , Webb JG , Tamburino C , et al . Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure . Circ Cardiovasc Interv . 2016 Sep ; 9 ( 9 ) : e003930 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Barbanti</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Webb</surname>
              <given-names>JG</given-names>
            </name>
            <name>
              <surname>Tamburino</surname>
              <given-names>C</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure</article-title>
          <source>Circ Cardiovasc Interv</source>
          <year>2016</year>
          <month>09</month>
          <volume>9</volume>
          <issue>9</issue>
          <elocation-id>e003930</elocation-id>
        </element-citation>
      </ref>
      <ref id="B63">
        <label>63</label>
        <mixed-citation>63. Wood DA , Lauck SB , Cairns JA . The Vancouver 3M (Multidisciplinary, Multimodality, But Minimalist) Clinical Pathway Facilitates Safe Next-Day Discharge Home at Low-, Medium-, and High-Volume Transfemoral Transcatheter Aortic Valve Replacement Centers: The 3M TAVR Study . JACC Cardiovasc Interv . 2019 Mar 11 ; 12 ( 5 ): 459 - 69 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Wood</surname>
              <given-names>DA</given-names>
            </name>
            <name>
              <surname>Lauck</surname>
              <given-names>SB</given-names>
            </name>
            <name>
              <surname>Cairns</surname>
              <given-names>JA</given-names>
            </name>
          </person-group>
          <article-title>The Vancouver 3M (Multidisciplinary, Multimodality, But Minimalist) Clinical Pathway Facilitates Safe Next-Day Discharge Home at Low-, Medium-, and High-Volume Transfemoral Transcatheter Aortic Valve Replacement Centers: The 3M TAVR Study</article-title>
          <source>JACC Cardiovasc Interv</source>
          <year>2019</year>
          <month>03</month>
          <day>11</day>
          <volume>12</volume>
          <issue>5</issue>
          <fpage>459</fpage>
          <lpage>469</lpage>
        </element-citation>
      </ref>
      <ref id="B64">
        <label>64</label>
        <mixed-citation>64. Howard C , Jullian L , Joshi M , Noshirwani A , Bashir M , Harky A . TAVI and the future of aortic valve replacement . J Card Surg . 2019 Dec ; 34 ( 12 ): 1577 - 1590 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Howard</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Jullian</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Joshi</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Noshirwani</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Bashir</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Harky</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>TAVI and the future of aortic valve replacement</article-title>
          <source>J Card Surg</source>
          <year>2019</year>
          <month>12</month>
          <volume>34</volume>
          <issue>12</issue>
          <fpage>1577</fpage>
          <lpage>1590</lpage>
        </element-citation>
      </ref>
      <ref id="B65">
        <label>65</label>
        <mixed-citation>65. Sawaya FJ , Deutsch MA , Seiffert M , et al . Safety and Efficacy of Transcatheter Aortic Valve Replacement in the Treatment of Pure Aortic Regurgitation in Native Valves and Failing Surgical Bioprostheses: Results From an International Registry Study . JACC Cardiovasc Interv . 2017 ; 10 ( 10 ): 1048 - 56 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Sawaya</surname>
              <given-names>FJ</given-names>
            </name>
            <name>
              <surname>Deutsch</surname>
              <given-names>MA</given-names>
            </name>
            <name>
              <surname>Seiffert</surname>
              <given-names>M</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Safety and Efficacy of Transcatheter Aortic Valve Replacement in the Treatment of Pure Aortic Regurgitation in Native Valves and Failing Surgical Bioprostheses: Results From an International Registry Study</article-title>
          <source>JACC Cardiovasc Interv</source>
          <year>2017</year>
          <volume>10</volume>
          <issue>10</issue>
          <fpage>1048</fpage>
          <lpage>1056</lpage>
        </element-citation>
      </ref>
      <ref id="B66">
        <label>66</label>
        <mixed-citation>66. Arsalan M , Walther T . Durability of prostheses for transcatheter aortic valve implantation . Nat Rev Cardiol . 2016 ; 13 ( 6 ): 360 - 7 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Arsalan</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Walther</surname>
              <given-names>T</given-names>
            </name>
          </person-group>
          <article-title>Durability of prostheses for transcatheter aortic valve implantation</article-title>
          <source>Nat Rev Cardiol</source>
          <year>2016</year>
          <volume>13</volume>
          <issue>6</issue>
          <fpage>360</fpage>
          <lpage>367</lpage>
        </element-citation>
      </ref>
      <ref id="B67">
        <label>67</label>
        <mixed-citation>67. Latib A , Naganuma T , Abdel-Wahab M , Danenberg H , Cota L , Barbanti M , et al . Treatment and clinical outcomes of transcatheter heart valve thrombosis . Circ Cardiovasc Interv . 2015 Apr ; 8 ( 4 ): e001779 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Latib</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Naganuma</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Abdel-Wahab</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Danenberg</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Cota</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Barbanti</surname>
              <given-names>M</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Treatment and clinical outcomes of transcatheter heart valve thrombosis</article-title>
          <source>Circ Cardiovasc Interv</source>
          <year>2015</year>
          <month>04</month>
          <volume>8</volume>
          <issue>4</issue>
          <elocation-id>e001779</elocation-id>
        </element-citation>
      </ref>
      <ref id="B68">
        <label>68</label>
        <mixed-citation>68. Chakravarty T , S&#248;ndergaard L , Friedman J , Backer O , Berman D , Kofoed KF , et al . RESOLVE ; SAVORY Investigators . Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study . Lancet . 2017 ; 389 ( 10087 ): 2383 - 92 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Chakravarty</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>S&#248;ndergaard</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Friedman</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Backer</surname>
              <given-names>O</given-names>
            </name>
            <name>
              <surname>Berman</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Kofoed</surname>
              <given-names>KF</given-names>
            </name>
            <etal>et al</etal>
            <collab>RESOLVE</collab>
            <collab>SAVORY Investigators</collab>
          </person-group>
          <article-title>Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study</article-title>
          <source>Lancet</source>
          <year>2017</year>
          <volume>389</volume>
          <issue>10087</issue>
          <fpage>2383</fpage>
          <lpage>2392</lpage>
        </element-citation>
      </ref>
      <ref id="B69">
        <label>69</label>
        <mixed-citation>69. Arsalan M , Walther T . Durability of prostheses for transcatheter aortic valve implantation . Nat Rev Cardiol . 2016 ; 13 ( 6 ): 360 - 7</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Arsalan</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Walther</surname>
              <given-names>T</given-names>
            </name>
          </person-group>
          <article-title>Durability of prostheses for transcatheter aortic valve implantation</article-title>
          <source>Nat Rev Cardiol</source>
          <year>2016</year>
          <volume>13</volume>
          <issue>6</issue>
          <fpage>360</fpage>
          <lpage>367</lpage>
        </element-citation>
      </ref>
      <ref id="B70">
        <label>70</label>
        <mixed-citation>70. Toggweiler , S. et al . 5year outcome after transcatheter aortic valve implantation . J Am Coll Cardiol 2013 ; 61 ( 4 ): 413 &#8211; 9 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Toggweiler</surname>
              <given-names>S.</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>5year outcome after transcatheter aortic valve implantation</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2013</year>
          <volume>61</volume>
          <issue>4</issue>
          <fpage>413</fpage>
          <lpage>419</lpage>
        </element-citation>
      </ref>
      <ref id="B71">
        <label>71</label>
        <mixed-citation>71. Barbanti , M , Petronio AS , Ettori F , et al . 5year outcomes after transcatheter aortic valve implantation with CoreValve prosthesis . JACC Cardiovasc Interv 2015 Jul ; 8 ( 8 ): 1084 - 91 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Barbanti</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Petronio</surname>
              <given-names>AS</given-names>
            </name>
            <name>
              <surname>Ettori</surname>
              <given-names>F</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>5year outcomes after transcatheter aortic valve implantation with CoreValve prosthesis</article-title>
          <source>JACC Cardiovasc Interv</source>
          <year>2015</year>
          <month>07</month>
          <volume>8</volume>
          <issue>8</issue>
          <fpage>1084</fpage>
          <lpage>1091</lpage>
        </element-citation>
      </ref>
      <ref id="B72">
        <label>72</label>
        <mixed-citation>72. Webb , J . New balloon expandable aortic valves . Presented at the 63rd Annual Scientific Session and Expo of the American College of Cardiology ( 2014 ).</mixed-citation>
        <element-citation publication-type="confproc">
          <person-group person-group-type="author">
            <name>
              <surname>Webb</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <source>New balloon expandable aortic valves</source>
          <conf-name>Presented at the 63rd Annual Scientific Session and Expo of the American College of Cardiology</conf-name>
          <year>2014</year>
        </element-citation>
      </ref>
      <ref id="B73">
        <label>73</label>
        <mixed-citation>73. Eltchaninoff H , Durand E , Avin&#233;e G , Tron C , Litzler PY , Bauer F , et al . Assessment of structural valve deterioration of transcatheter aortic bioprosthetic balloon-expandable valves using the new European consensus definition . EuroIntervention 2018 ; 14 ( 3 ): e264 - 71 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Eltchaninoff</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Durand</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Avin&#233;e</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Tron</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Litzler</surname>
              <given-names>PY</given-names>
            </name>
            <name>
              <surname>Bauer</surname>
              <given-names>F</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Assessment of structural valve deterioration of transcatheter aortic bioprosthetic balloon-expandable valves using the new European consensus definition</article-title>
          <source>EuroIntervention</source>
          <year>2018</year>
          <volume>14</volume>
          <issue>3</issue>
          <fpage>e264</fpage>
          <lpage>e271</lpage>
        </element-citation>
      </ref>
      <ref id="B74">
        <label>74</label>
        <mixed-citation>74. Barbanti M , Costa G , Zappulla P , Todaro D , Picci A , Rapisarda G , et al . Incidence of long-term structural valve dysfunction and bioprosthetic valve failure after transcatheter aortic valve replacement . J Am Heart Assoc 2018 ; 7 ( 15 ): e008440 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Barbanti</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Costa</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Zappulla</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Todaro</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Picci</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Rapisarda</surname>
              <given-names>G</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Incidence of long-term structural valve dysfunction and bioprosthetic valve failure after transcatheter aortic valve replacement</article-title>
          <source>J Am Heart Assoc</source>
          <year>2018</year>
          <volume>7</volume>
          <issue>15</issue>
          <elocation-id>e008440</elocation-id>
        </element-citation>
      </ref>
      <ref id="B75">
        <label>75</label>
        <mixed-citation>75. Panico AR , Giannini C , De Carlo M , Angelillis M , Spontoni P , Pieroni A , et al . Long-term results and durability of the CoreValve transcatheter aortic bioprosthesis: outcomes beyond five years . EuroIntervention 2019 ; 14 ( 16 ): 1639 &#8211; 47 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Panico</surname>
              <given-names>AR</given-names>
            </name>
            <name>
              <surname>Giannini</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>De Carlo</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Angelillis</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Spontoni</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Pieroni</surname>
              <given-names>A</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Long-term results and durability of the CoreValve transcatheter aortic bioprosthesis: outcomes beyond five years</article-title>
          <source>EuroIntervention</source>
          <year>2019</year>
          <volume>14</volume>
          <issue>16</issue>
          <fpage>1639</fpage>
          <lpage>1647</lpage>
        </element-citation>
      </ref>
      <ref id="B76">
        <label>76</label>
        <mixed-citation>76. Holy EW , Kebernik J , Abdelghani M , Stamplfi SF , Hellermann J , Allali A , et al . Long-term durability and haemodynamic performance of a selfexpanding transcatheter heart valve beyond five years after implantation: a prospective observational study applying the standardised definitions of structural deterioration and valve failure . EuroIntervention 2018 ; 14 ( 14 ): e390 &#8211; 6 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Holy</surname>
              <given-names>EW</given-names>
            </name>
            <name>
              <surname>Kebernik</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Abdelghani</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Stamplfi</surname>
              <given-names>SF</given-names>
            </name>
            <name>
              <surname>Hellermann</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Allali</surname>
              <given-names>A</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Long-term durability and haemodynamic performance of a selfexpanding transcatheter heart valve beyond five years after implantation: a prospective observational study applying the standardised definitions of structural deterioration and valve failure</article-title>
          <source>EuroIntervention</source>
          <year>2018</year>
          <volume>14</volume>
          <issue>14</issue>
          <fpage>e390</fpage>
          <lpage>e396</lpage>
        </element-citation>
      </ref>
      <ref id="B77">
        <label>77</label>
        <mixed-citation>77. Deutsch M-A , Erlebach M , Burri M , Hapfelmeier , Witt OG , Ziegemueller JA , et al . Beyond the fiveyear horizon: long-term outcome of high-risk and inoperable patients undergoing TAVR with first-generation devices . EuroIntervention 2018 ; 14 ( 1 ): 41 &#8211; 9 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Deutsch</surname>
              <given-names>M-A</given-names>
            </name>
            <name>
              <surname>Erlebach</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Burri</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Hapfelmeier</surname>
            </name>
            <name>
              <surname>Witt</surname>
              <given-names>OG</given-names>
            </name>
            <name>
              <surname>Ziegemueller</surname>
              <given-names>JA</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Beyond the fiveyear horizon: long-term outcome of high-risk and inoperable patients undergoing TAVR with first-generation devices</article-title>
          <source>EuroIntervention</source>
          <year>2018</year>
          <volume>14</volume>
          <issue>1</issue>
          <fpage>41</fpage>
          <lpage>49</lpage>
        </element-citation>
      </ref>
      <ref id="B78">
        <label>78</label>
        <mixed-citation>78. Toggweiler S , Leipsic J , Binder RK , Freeman M , Barbanti M , Heijmen RH , et al . Management of vascular access in transcatheter aortic valve replacement: part 2: Vascular complications . JACC Cardiovasc Interv . 2013 ; 6 ( 8 ): 767 - 76</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Toggweiler</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Leipsic</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Binder</surname>
              <given-names>RK</given-names>
            </name>
            <name>
              <surname>Freeman</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Barbanti</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Heijmen</surname>
              <given-names>RH</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Management of vascular access in transcatheter aortic valve replacement: part 2: Vascular complications</article-title>
          <source>JACC Cardiovasc Interv</source>
          <year>2013</year>
          <volume>6</volume>
          <issue>8</issue>
          <fpage>767</fpage>
          <lpage>776</lpage>
        </element-citation>
      </ref>
      <ref id="B79">
        <label>79</label>
        <mixed-citation>79. Auffret V , Regueiro A , Del Trigo M , Altisent OA , Parada FC , Chiche O , et al . Predictors of Early Cerebrovascular Events in Patients With Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement . J Am Coll Cardiol . 2016 ; 68 ( 7 ): 673 - 84</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Auffret</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Regueiro</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Del Trigo</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Altisent</surname>
              <given-names>OA</given-names>
            </name>
            <name>
              <surname>Parada</surname>
              <given-names>FC</given-names>
            </name>
            <name>
              <surname>Chiche</surname>
              <given-names>O</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Predictors of Early Cerebrovascular Events in Patients With Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2016</year>
          <volume>68</volume>
          <issue>7</issue>
          <fpage>673</fpage>
          <lpage>684</lpage>
        </element-citation>
      </ref>
      <ref id="B80">
        <label>80</label>
        <mixed-citation>80. Giustino G , Sorrentino S , Mehran R , Faggioni M , Dangas G . Cerebral Embolic Protection During TAVR: A Clinical Event Meta- Analysis . J Am Coll Cardiol . 2017 ; 69 ( 4 ): 465 - 6 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Giustino</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Sorrentino</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Mehran</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Faggioni</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Dangas</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
          <article-title>Cerebral Embolic Protection During TAVR: A Clinical Event Meta- Analysis</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2017</year>
          <volume>69</volume>
          <issue>4</issue>
          <fpage>465</fpage>
          <lpage>466</lpage>
        </element-citation>
      </ref>
      <ref id="B81">
        <label>81</label>
        <mixed-citation>81. Barbanti M , Gulino S , Costa G , Tamburino C . Pathophysiology, incidence and predictors of conduction disturbances during Transcatheter Aortic Valve Implantation . Expert Rev Med Devices . 2017 ; 14 ( 2 ): 135 - 47 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Barbanti</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Gulino</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Costa</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Tamburino</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>Pathophysiology, incidence and predictors of conduction disturbances during Transcatheter Aortic Valve Implantation</article-title>
          <source>Expert Rev Med Devices</source>
          <year>2017</year>
          <volume>14</volume>
          <issue>2</issue>
          <fpage>135</fpage>
          <lpage>147</lpage>
        </element-citation>
      </ref>
      <ref id="B82">
        <label>82</label>
        <mixed-citation>82. G&#233;n&#233;reux P , Head SJ , Van Mieghem , Kodali S , Kirtane AJ , Xu K , et al . Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies . J Am Coll Cardiol . 2012 ; 59 ( 25 ): 2317 - 26 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>G&#233;n&#233;reux</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Head</surname>
              <given-names>SJ</given-names>
            </name>
            <name>
              <surname>Mieghem</surname>
              <given-names>Van</given-names>
            </name>
            <name>
              <surname>Kodali</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Kirtane</surname>
              <given-names>AJ</given-names>
            </name>
            <name>
              <surname>Xu</surname>
              <given-names>K</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2012</year>
          <volume>59</volume>
          <issue>25</issue>
          <fpage>2317</fpage>
          <lpage>2326</lpage>
        </element-citation>
      </ref>
      <ref id="B83">
        <label>83</label>
        <mixed-citation>83. Athappan G , Gajulapalli RD , Sengodan P , Bhardwaj A , Ellis SG , Svensson L , et al . Influence of transcatheter aortic valve replacement strategy and valve design on stroke after transcatheter aortic valve replacement: a meta-analysis and systematic review of literature . J Am Coll Cardiol . 2014 ; 63 ( 20 ): 2101 - 10 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Athappan</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Gajulapalli</surname>
              <given-names>RD</given-names>
            </name>
            <name>
              <surname>Sengodan</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Bhardwaj</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Ellis</surname>
              <given-names>SG</given-names>
            </name>
            <name>
              <surname>Svensson</surname>
              <given-names>L</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Influence of transcatheter aortic valve replacement strategy and valve design on stroke after transcatheter aortic valve replacement: a meta-analysis and systematic review of literature</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2014</year>
          <volume>63</volume>
          <issue>20</issue>
          <fpage>2101</fpage>
          <lpage>2110</lpage>
        </element-citation>
      </ref>
      <ref id="B84">
        <label>84</label>
        <mixed-citation>84. Mylotte D , Andalib A , Theriault-Lauzier P , Dorfmeister M , Girgis M , Alharbi W , et al . Transcatheter heart valve failure: a systematic review . Eur Heart J 2015 ; 36 ( 21 ): 1306 &#8211; 27 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Mylotte</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Andalib</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Theriault-Lauzier</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Dorfmeister</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Girgis</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Alharbi</surname>
              <given-names>W</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter heart valve failure: a systematic review</article-title>
          <source>Eur Heart J</source>
          <year>2015</year>
          <volume>36</volume>
          <issue>21</issue>
          <fpage>1306</fpage>
          <lpage>1327</lpage>
        </element-citation>
      </ref>
      <ref id="B85">
        <label>85</label>
        <mixed-citation>85. Latib A , Naganuma T , Abdel-Wahab M , Danenberg H , Costa L , Barbanti M , et al . Treatment and clinical outcomes of transcatheter heart valve thrombosis . Circ Cardiovasc Interv 2015 ; 8 ( 4 ): e001779</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Latib</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Naganuma</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Abdel-Wahab</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Danenberg</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Costa</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Barbanti</surname>
              <given-names>M</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Treatment and clinical outcomes of transcatheter heart valve thrombosis</article-title>
          <source>Circ Cardiovasc Interv</source>
          <year>2015</year>
          <volume>8</volume>
          <issue>4</issue>
          <elocation-id>e001779</elocation-id>
        </element-citation>
      </ref>
      <ref id="B86">
        <label>86</label>
        <mixed-citation>86. Kanjanauthai S , Pirelli L , Nalluri N , Kliger CA . Subclinical leaflet thrombosis following transcatheter aortic valve replacement . J Interv Cardiol 2018 ; 31 ( 5 ): 640 &#8211; 7</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Kanjanauthai</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Pirelli</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Nalluri</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Kliger</surname>
              <given-names>CA</given-names>
            </name>
          </person-group>
          <article-title>Subclinical leaflet thrombosis following transcatheter aortic valve replacement</article-title>
          <source>J Interv Cardiol</source>
          <year>2018</year>
          <volume>31</volume>
          <issue>5</issue>
          <fpage>640</fpage>
          <lpage>647</lpage>
        </element-citation>
      </ref>
      <ref id="B87">
        <label>87</label>
        <mixed-citation>87. Latib A , Naim C , De Bonis M , Sinning JM , Maisano F , Barbanti M , et al . TAVR-associated prosthetic valve infective endocarditis . J Am Coll Cardiol 2014 ; 64 ( 20 ): 2176 &#8211; 8 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Latib</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Naim</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>De Bonis</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Sinning</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Maisano</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Barbanti</surname>
              <given-names>M</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>TAVR-associated prosthetic valve infective endocarditis</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2014</year>
          <volume>64</volume>
          <issue>20</issue>
          <fpage>2176</fpage>
          <lpage>2178</lpage>
        </element-citation>
      </ref>
      <ref id="B88">
        <label>88</label>
        <mixed-citation>88. Kappetein AP , Head SJ , Philippe GE , Piazza N , Mieghem NM , Blackstone EH , et al . Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document . J Thorac Cardiovasc Surg 2013 ; 145 ( 1 ): 6 - 23</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Kappetein</surname>
              <given-names>AP</given-names>
            </name>
            <name>
              <surname>Head</surname>
              <given-names>SJ</given-names>
            </name>
            <name>
              <surname>Philippe</surname>
              <given-names>GE</given-names>
            </name>
            <name>
              <surname>Piazza</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Mieghem</surname>
              <given-names>NM</given-names>
            </name>
            <name>
              <surname>Blackstone</surname>
              <given-names>EH</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <year>2013</year>
          <volume>145</volume>
          <issue>1</issue>
          <fpage>6</fpage>
          <lpage>23</lpage>
        </element-citation>
      </ref>
      <ref id="B89">
        <label>89</label>
        <mixed-citation>89. Baumgartner H , Falk V , Bax JJ , Bonis M , Hamm C , Holm PJ , et al . 2017 ESC/EACTS Guidelines for the management of valvular heart disease . Eur Heart J 2017 ; 38 ( 36 ): 2739 &#8211; 91 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Baumgartner</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Falk</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Bax</surname>
              <given-names>JJ</given-names>
            </name>
            <name>
              <surname>Bonis</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Hamm</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Holm</surname>
              <given-names>PJ</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>2017 ESC/EACTS Guidelines for the management of valvular heart disease</article-title>
          <source>Eur Heart J</source>
          <year>2017</year>
          <volume>38</volume>
          <issue>36</issue>
          <fpage>2739</fpage>
          <lpage>2791</lpage>
        </element-citation>
      </ref>
      <ref id="B90">
        <label>90</label>
        <mixed-citation>90. Nishimura RA , Otto CM , Bonow RO , Carabello BA , Erwinlll , JP , Fleisher LA , et al . 2017 AHA/ACC Focused Update of the 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American heart association task force on clinical practice guidelines . J Am Coll Cardiol 2017 ; 70 ( 25 ): 252 &#8211; 89 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Nishimura</surname>
              <given-names>RA</given-names>
            </name>
            <name>
              <surname>Otto</surname>
              <given-names>CM</given-names>
            </name>
            <name>
              <surname>Bonow</surname>
              <given-names>RO</given-names>
            </name>
            <name>
              <surname>Carabello</surname>
              <given-names>BA</given-names>
            </name>
            <name>
              <surname>Erwinlll</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>Fleisher</surname>
              <given-names>LA</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>2017 AHA/ACC Focused Update of the 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American heart association task force on clinical practice guidelines</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2017</year>
          <volume>70</volume>
          <issue>25</issue>
          <fpage>252</fpage>
          <lpage>289</lpage>
        </element-citation>
      </ref>
      <ref id="B91">
        <label>91</label>
        <mixed-citation>91. Stortecky S , Buellesfeld L , Wenaweser P , Heg D , Pilgrim T , Khattab AA , et al . Atrial fibrillation and aortic stenosis: impact on clinical outcomes among patients undergoing transcatheter aortic valve implantation . Circ Cardiovasc Interv 2013 ; 6 ( 1 ): 77 &#8211; 84 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Stortecky</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Buellesfeld</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Wenaweser</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Heg</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Pilgrim</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Khattab</surname>
              <given-names>AA</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Atrial fibrillation and aortic stenosis: impact on clinical outcomes among patients undergoing transcatheter aortic valve implantation</article-title>
          <source>Circ Cardiovasc Interv</source>
          <year>2013</year>
          <volume>6</volume>
          <issue>1</issue>
          <fpage>77</fpage>
          <lpage>84</lpage>
        </element-citation>
      </ref>
      <ref id="B92">
        <label>92</label>
        <mixed-citation>92. G&#233;n&#233;reux P , Cohen DJ , Mack M , Cabau JR , Yadav M , Xu K , et al . Incidence, predictors, and prognostic impact of late bleeding complications after transcatheter aortic valve replacement . J Am Coll Cardiol 2014 ; 64 ( 24 ): 2605 &#8211; 15 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>G&#233;n&#233;reux</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Cohen</surname>
              <given-names>DJ</given-names>
            </name>
            <name>
              <surname>Mack</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Cabau</surname>
              <given-names>JR</given-names>
            </name>
            <name>
              <surname>Yadav</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Xu</surname>
              <given-names>K</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Incidence, predictors, and prognostic impact of late bleeding complications after transcatheter aortic valve replacement</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2014</year>
          <volume>64</volume>
          <issue>24</issue>
          <fpage>2605</fpage>
          <lpage>2615</lpage>
        </element-citation>
      </ref>
      <ref id="B93">
        <label>93</label>
        <mixed-citation>93. Dangas GD , Tijssen JGP , W&#246;hrle J , Sondergaard L , Gilard M , Mollmann H , el al GALILEO Investigators . A Controlled Trial of Rivaroxaban after Transcatheter Aortic-Valve Replacement . N Engl J Med . 2020 Jan 9 ; 382 ( 2 ): 120 - 129 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Dangas</surname>
              <given-names>GD</given-names>
            </name>
            <name>
              <surname>Tijssen</surname>
              <given-names>JGP</given-names>
            </name>
            <name>
              <surname>W&#246;hrle</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Sondergaard</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Gilard</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Mollmann</surname>
              <given-names>H</given-names>
            </name>
            <collab>el al GALILEO Investigators</collab>
          </person-group>
          <article-title>A Controlled Trial of Rivaroxaban after Transcatheter Aortic-Valve Replacement</article-title>
          <source>N Engl J Med</source>
          <year>2020</year>
          <month>01</month>
          <day>9</day>
          <volume>382</volume>
          <issue>2</issue>
          <fpage>120</fpage>
          <lpage>129</lpage>
        </element-citation>
      </ref>
      <ref id="B94">
        <label>94</label>
        <mixed-citation>94. Nishimura RA , Otto CM , Bonow RO , Carabello BA , Erwin JP 3rd , Fleisher LA , et al . 2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines . Circulation . 2017 ; 135 ( 25 ): e1159 - 95 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Nishimura</surname>
              <given-names>RA</given-names>
            </name>
            <name>
              <surname>Otto</surname>
              <given-names>CM</given-names>
            </name>
            <name>
              <surname>Bonow</surname>
              <given-names>RO</given-names>
            </name>
            <name>
              <surname>Carabello</surname>
              <given-names>BA</given-names>
            </name>
            <name>
              <surname>Erwin</surname>
              <given-names>JP</given-names>
              <suffix>3rd</suffix>
            </name>
            <name>
              <surname>Fleisher</surname>
              <given-names>LA</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines</article-title>
          <source>Circulation</source>
          <year>2017</year>
          <volume>135</volume>
          <issue>25</issue>
          <fpage>e1159</fpage>
          <lpage>e1195</lpage>
        </element-citation>
      </ref>
      <ref id="B95">
        <label>95</label>
        <mixed-citation>95. Pilgrim T , Windecker S . Expansion of transcatheter aortic valve implantation: new indications and socio-economic considerations . Euro Heart J 2018 ; 39 ( 28 ): 2643 &#8211; 5 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Pilgrim</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Windecker</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
          <article-title>Expansion of transcatheter aortic valve implantation: new indications and socio-economic considerations</article-title>
          <source>Euro Heart J</source>
          <year>2018</year>
          <volume>39</volume>
          <issue>28</issue>
          <fpage>2643</fpage>
          <lpage>2645</lpage>
        </element-citation>
      </ref>
      <ref id="B96">
        <label>96</label>
        <mixed-citation>96. Lung B , Baron G , Butchart EG , Delahaye F , Barwolf CG , Levang OW , et al . A prospective survey of patients with valvular heart disease in Europe: the Euro Heart Survey on Valvular Heart Disease . Eur Heart J 2003 ; 24 ( 13 ): 1231 &#8211; 43 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Lung</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Baron</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Butchart</surname>
              <given-names>EG</given-names>
            </name>
            <name>
              <surname>Delahaye</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Barwolf</surname>
              <given-names>CG</given-names>
            </name>
            <name>
              <surname>Levang</surname>
              <given-names>OW</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>A prospective survey of patients with valvular heart disease in Europe: the Euro Heart Survey on Valvular Heart Disease</article-title>
          <source>Eur Heart J</source>
          <year>2003</year>
          <volume>24</volume>
          <issue>13</issue>
          <fpage>1231</fpage>
          <lpage>1243</lpage>
        </element-citation>
      </ref>
      <ref id="B97">
        <label>97</label>
        <mixed-citation>97. Vahanian A , Alfieri O , Andreotti F , Antunes MJ , Esquivias GB , Baumgartner H , et al . Guidelines on the management of valvular heart disease (version 2012): the Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) . Eur J Cardiothorac Surg 2012 ; 33 ( 19 ): 2451 - 96 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Vahanian</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Alfieri</surname>
              <given-names>O</given-names>
            </name>
            <name>
              <surname>Andreotti</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Antunes</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Esquivias</surname>
              <given-names>GB</given-names>
            </name>
            <name>
              <surname>Baumgartner</surname>
              <given-names>H</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Guidelines on the management of valvular heart disease (version 2012): the Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS)</article-title>
          <source>Eur J Cardiothorac Surg</source>
          <year>2012</year>
          <volume>33</volume>
          <issue>19</issue>
          <fpage>2451</fpage>
          <lpage>2496</lpage>
        </element-citation>
      </ref>
      <ref id="B98">
        <label>98</label>
        <mixed-citation>98. Nishimura RA , Otto CM , Bonow RO , Carabello BA , Erwinlll JP , Fleisher LA , et al . 2017 AHA/ACC focused update of the 2014 AHA/ACC Guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines . J Am Coll Cardiol 2017 ; 70 ( 25 ): 252 &#8211; 89 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Nishimura</surname>
              <given-names>RA</given-names>
            </name>
            <name>
              <surname>Otto</surname>
              <given-names>CM</given-names>
            </name>
            <name>
              <surname>Bonow</surname>
              <given-names>RO</given-names>
            </name>
            <name>
              <surname>Carabello</surname>
              <given-names>BA</given-names>
            </name>
            <name>
              <surname>Erwinlll</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>Fleisher</surname>
              <given-names>LA</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>2017 AHA/ACC focused update of the 2014 AHA/ACC Guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2017</year>
          <volume>70</volume>
          <issue>25</issue>
          <fpage>252</fpage>
          <lpage>289</lpage>
        </element-citation>
      </ref>
      <ref id="B99">
        <label>99</label>
        <mixed-citation>99. Maeno Y , Yoon SH , Abramowitz Y , Watanabe Y , Jilaihawi H , Lin MS , et al . Effect of ascending aortic dimension on acute procedural success following self-expanding transcatheter aortic valve replacement: a multicenter retrospective analysis . Int J Cardiol 2017 ; 244 : 100 &#8211; 5 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Maeno</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Yoon</surname>
              <given-names>SH</given-names>
            </name>
            <name>
              <surname>Abramowitz</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Watanabe</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Jilaihawi</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Lin</surname>
              <given-names>MS</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Effect of ascending aortic dimension on acute procedural success following self-expanding transcatheter aortic valve replacement: a multicenter retrospective analysis</article-title>
          <source>Int J Cardiol</source>
          <year>2017</year>
          <volume>244</volume>
          <fpage>100</fpage>
          <lpage>105</lpage>
        </element-citation>
      </ref>
      <ref id="B100">
        <label>100</label>
        <mixed-citation>100. Alkhouli M , Sengupta P , Badhwar V . Toward precision in balloon-expandable tavr: oversizing tight versus just right . JACC Cardiovasc Interv 2017 ; 10 ( 8 ): 821 &#8211; 3 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Alkhouli</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Sengupta</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Badhwar</surname>
              <given-names>V</given-names>
            </name>
          </person-group>
          <article-title>Toward precision in balloon-expandable tavr: oversizing tight versus just right</article-title>
          <source>JACC Cardiovasc Interv</source>
          <year>2017</year>
          <volume>10</volume>
          <issue>8</issue>
          <fpage>821</fpage>
          <lpage>823</lpage>
        </element-citation>
      </ref>
      <ref id="B101">
        <label>101</label>
        <mixed-citation>101. Dvir D , Webb JG , Piazza N , Blanke P , Barbanti M , Bleiziffer S , et al . Multicenter evaluation of transcatheter aortic valve replacement using either SAPIEN XT or CoreValve: degree of device oversizing by computedtomography and clinical outcomes . Catheter Cardiovasc Interv 2015 ; 86 ( 3 ): 508 &#8211; 15 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Dvir</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Webb</surname>
              <given-names>JG</given-names>
            </name>
            <name>
              <surname>Piazza</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Blanke</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Barbanti</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Bleiziffer</surname>
              <given-names>S</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Multicenter evaluation of transcatheter aortic valve replacement using either SAPIEN XT or CoreValve: degree of device oversizing by computedtomography and clinical outcomes</article-title>
          <source>Catheter Cardiovasc Interv</source>
          <year>2015</year>
          <volume>86</volume>
          <issue>3</issue>
          <fpage>508</fpage>
          <lpage>515</lpage>
        </element-citation>
      </ref>
      <ref id="B102">
        <label>102</label>
        <mixed-citation>102. Pesarini G , Lunardi M , Piccoli A , Gottin L , Prati D , Ferrero V , et al . Effectiveness and safety of transcatheter aortic valve implantation in patients with pure aortic regurgitation and advanced heart failure . Am J Cardiol 2018 ; 121 ( 5 ): 642 &#8211; 8 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Pesarini</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Lunardi</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Piccoli</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Gottin</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Prati</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Ferrero</surname>
              <given-names>V</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Effectiveness and safety of transcatheter aortic valve implantation in patients with pure aortic regurgitation and advanced heart failure</article-title>
          <source>Am J Cardiol</source>
          <year>2018</year>
          <volume>121</volume>
          <issue>5</issue>
          <fpage>642</fpage>
          <lpage>648</lpage>
        </element-citation>
      </ref>
      <ref id="B103">
        <label>103</label>
        <mixed-citation>103. Nakamura Y , Teefy P , Kiaii B , Syed J , Jones PM , Bainbridge D , et al . Transcatheter aortic valve implantation in a patient with severe aortic insufficiency and minimal aortic annular calcification . Can J Cardiol 2013 ; 29 ( 9 ): 1138 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Nakamura</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Teefy</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Kiaii</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Syed</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Jones</surname>
              <given-names>PM</given-names>
            </name>
            <name>
              <surname>Bainbridge</surname>
              <given-names>D</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter aortic valve implantation in a patient with severe aortic insufficiency and minimal aortic annular calcification</article-title>
          <source>Can J Cardiol</source>
          <year>2013</year>
          <volume>29</volume>
          <issue>9</issue>
          <size units="pages">1138</size>
        </element-citation>
      </ref>
      <ref id="B104">
        <label>104</label>
        <mixed-citation>104. Kumar A , Sato K , Banerjee K , Narayanswami J , Betancor J , Menon V , et al . Hemodynamic durability of transcatheter aortic valves using the updated Valve Academic Research Consortium-2 criteria . Catheter Cardiovasc Interv 2019 Mar 1 ; 93 ( 4 ): 729 - 38</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Kumar</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Sato</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Banerjee</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Narayanswami</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Betancor</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Menon</surname>
              <given-names>V</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Hemodynamic durability of transcatheter aortic valves using the updated Valve Academic Research Consortium-2 criteria</article-title>
          <source>Catheter Cardiovasc Interv</source>
          <year>2019</year>
          <month>03</month>
          <day>1</day>
          <volume>93</volume>
          <issue>4</issue>
          <fpage>729</fpage>
          <lpage>738</lpage>
        </element-citation>
      </ref>
      <ref id="B105">
        <label>105</label>
        <mixed-citation>105. Yoon SH , Schmidt T , Bleiziffer S , Schofer N , Fiorina C , Garcia AJ , et al . Transcatheter aortic valve replacement in pure native aortic valve regurgitation . J Am Coll Cardiol 2017 ; 70 ( 22 ): 2752 &#8211; 63 .</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Yoon</surname>
              <given-names>SH</given-names>
            </name>
            <name>
              <surname>Schmidt</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Bleiziffer</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Schofer</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Fiorina</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Garcia</surname>
              <given-names>AJ</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Transcatheter aortic valve replacement in pure native aortic valve regurgitation</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2017</year>
          <volume>70</volume>
          <issue>22</issue>
          <fpage>2752</fpage>
          <lpage>2763</lpage>
        </element-citation>
      </ref>
    </ref-list>
    <fn-group>
      <fn fn-type="other">
        <p>Ethics Approval and Consent to Participate</p>
        <p>This article does not contain any studies with human participants or animals performed by any of the authors.</p>
      </fn>
      <fn fn-type="other">
        <p>Study Association</p>
        <p>This study is not associated with any thesis or dissertation work.</p>
      </fn>
    </fn-group>
    <fn-group>
      <fn fn-type="supported-by">
        <p>Sources of Funding</p>
        <p>There were no external funding sources for this study.</p>
      </fn>
    </fn-group>
  </back>
</article>
