<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">5kG43QVQnVSHKmkDZ9JnDtG</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2012000100007</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(12)09800107</article-id>
      <article-id pub-id-type="doi">10.1590/S0066-782X2011005000118</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigos Originais</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Implante de Stent guiado por ultrassom intracoronariano melhora desfechos: meta-an&#225;lise de ensaios randomizados</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Sbruzzi</surname>
            <given-names>Graciele</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Quadros</surname>
            <given-names>Alexandre Schaan de</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Ribeiro</surname>
            <given-names>Rodrigo Antonini</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Abelin</surname>
            <given-names>An&#237;bal Pereira</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Berwanger</surname>
            <given-names>Ot&#225;vio</given-names>
          </name>
          <xref ref-type="aff" rid="aff04"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Plentz</surname>
            <given-names>Rodrigo Della Me&#227;</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Schann</surname>
            <given-names>Beatriz DAgord</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff03"/>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <addr-line>
          <named-content content-type="city">Porto Alegre</named-content>
          <named-content content-type="state">Rio Grande do Sul</named-content>
        </addr-line>
        <institution content-type="orgname">Funda&#231;&#227;o Universit&#225;ria de Cardiologia</institution>
        <institution content-type="orgdiv1">Instituto de Cardiologia do Rio Grande do Sul </institution>
        <country country="BR">Brazil</country>
      </aff>
      <aff id="aff02">
        <addr-line>
          <named-content content-type="city">Porto Alegre</named-content>
          <named-content content-type="state">Rio Grande do Sul</named-content>
        </addr-line>
        <institution content-type="orgname">Universidade Federal de Ci&#234;ncias da Sa&#250;de de Porto Alegre</institution>
        <country country="BR">Brazil</country>
      </aff>
      <aff id="aff04">
        <addr-line>
          <named-content content-type="city">S&#227;o Paulo</named-content>
          <named-content content-type="state"/>
        </addr-line>
        <institution content-type="orgname">Hospital do Cora&#231;&#227;o</institution>
        <institution content-type="orgdiv1">Instituto de Ensino e Pesquisa </institution>
        <country country="BR">Brazil</country>
      </aff>
      <aff id="aff03">
        <addr-line>
          <named-content content-type="city">Porto Alegre</named-content>
          <named-content content-type="state">Rio Grande do Sul</named-content>
        </addr-line>
        <institution content-type="orgname">Universidade Federal do Rio Grande do Sul</institution>
        <institution content-type="orgdiv1">Hospital de Cl&#237;nicas de Porto Alegre </institution>
        <country country="BR">Brazil</country>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>01</month>
        <year>2012</year>
      </pub-date>
      <volume>98</volume>
      <issue>1</issue>
      <fpage>35</fpage>
      <lpage>44</lpage>
      <history>
        <date date-type="received">
          <day>06</day>
          <month>04</month>
          <year>2011</year>
        </date>
        <date date-type="accepted">
          <day>14</day>
          <month>06</month>
          <year>2011</year>
        </date>
        <date date-type="rev-recd">
          <day>25</day>
          <month>05</month>
          <year>2011</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <abstract>
        <p>FUNDAMENTO: Ultrassom Intracoronariano (USIC) tem sido usado como um m&#233;todo auxiliar a fim de otimizar o implante de stents. No entanto, o impacto desse m&#233;todo em alguns resultados &#233; controverso. OBJETIVO: Analisar sistematicamente o impacto dos stents coronarianos guiados por USIC, em compara&#231;&#227;o com os stents guiados angiograficamente, sobre os resultados cl&#237;nicos e angiogr&#225;ficos. M&#201;TODOS: Foi realizada uma busca em bases de dados (MEDLINE, Cochrane CENTRAL, EMBASE) e refer&#234;ncias de estudos publicados entre 1982 e 2010. Foram inclu&#237;dos Ensaios Cl&#237;nicos Randomizados (ECR) que compararam o implante de stents coronarianos guiados por angiografia e USIC versus implante de stents coronarianos guiados apenas por angiografia (ANGIO). O seguimento m&#237;nimo foi de seis meses e os resultados avaliados foram eventos card&#237;acos adversos importantes (MACE), Revasculariza&#231;&#227;o da Les&#227;o-alvo (RLA) e reestenose angiogr&#225;fica. Dois revisores extra&#237;ram os dados de forma independente. Raz&#227;o de risco sum&#225;rio e intervalos de confian&#231;a de 95% (CI) foram calculados com modelos com efeitos aleat&#243;rios. A abordagem GRADE foi utilizada para determinar a qualidade geral de evid&#234;ncias para cada resultado. RESULTADOS: Dos 3.631 artigos identificados, oito ECR avaliando um total de 2.341 pacientes foram inclu&#237;dos. Houve uma redu&#231;&#227;o de 27% na reestenose angiogr&#225;fica (95% IC: 3% -46%) e uma redu&#231;&#227;o de 38% em RLA (95% IC: 17% -53%) em favor de USIC versus ANGIO. No entanto, os MACE n&#227;o foram reduzidos por USIC (RR: 0,79; 95%CI: 0,61-1,03). Os dados MACE representam apenas 47% do tamanho &#243;timo de informa&#231;&#245;es necess&#225;rias para detectar com seguran&#231;a um efeito de tratamento plaus&#237;vel. CONCLUS&#213;ES: Observamos que o implante de stent coronariano guiado por USIC oferece redu&#231;&#245;es significativas em RLA e reestenose angiogr&#225;fica em compara&#231;&#227;o com implante de stent guiado por angiografia, por&#233;m n&#227;o reduz casos de MACE.</p>
      </abstract>
      <kwd-group xml:lang="pt" kwd-group-type="author-generated">
        <kwd>Ultrassonografia de interven&#231;&#227;o</kwd>
        <kwd>metan&#225;lise</kwd>
        <kwd>ensaios cl&#237;nicos controlados aleat&#243;rios</kwd>
      </kwd-group>
      <pub-date publication-format="electronic" date-type="pub">
        <day>13</day>
        <month>12</month>
        <year>2011</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>Implante de Stent guiado por ultrassom intracoronariano melhora desfechos: meta-an&#225;lise de ensaios randomizados</p>
    <p>
      <bold>Graciele Sbruzzi<sup>I</sup>; Alexandre Schaan de Quadros<sup>I</sup>; Rodrigo Antonini Ribeiro<sup>I</sup>; An&#237;bal Pereira Abelin<sup>I</sup>; Ot&#225;vio Berwanger<sup>IV</sup>; Rodrigo Della Me&#227; Plentz<sup>I, II</sup>; Beatriz DAgord Schann<sup>I, III</sup></bold>
    </p>
    <p><sup>I</sup>Instituto de Cardiologia do Rio Grande do Sul/Funda&#231;&#227;o Universit&#225;ria de Cardiologia, Porto Alegre, RS, Brasil</p>
    <p><sup>II</sup>Universidade Federal de Ci&#234;ncias da Sa&#250;de de Porto Alegre, Porto Alegre, RS, Brasil</p>
    <p><sup>III</sup>Hospital de Cl&#237;nicas de Porto Alegre/Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brasil</p>
    <p><sup>IV</sup>Instituto de Ensino e Pesquisa do HCor (Hospital do Cora&#231;&#227;o), S&#227;o Paulo, SP, Brasil</p>
    <p>
      <xref ref-type="corresp" rid="end">Correspond&#234;ncia</xref>
    </p>
    <p>
      <bold>RESUMO</bold>
    </p>
    <p><bold>FUNDAMENTO:</bold> Ultrassom Intracoronariano (USIC) tem sido usado como um m&#233;todo auxiliar a fim de otimizar o implante de stents. No entanto, o impacto desse m&#233;todo em alguns resultados &#233; controverso.</p>
    <p><bold>OBJETIVO:</bold> Analisar sistematicamente o impacto dos stents coronarianos guiados por USIC, em compara&#231;&#227;o com os stents guiados angiograficamente, sobre os resultados cl&#237;nicos e angiogr&#225;ficos.</p>
    <p><bold>M&#201;TODOS:</bold> Foi realizada uma busca em bases de dados (MEDLINE, Cochrane CENTRAL, EMBASE) e refer&#234;ncias de estudos publicados entre 1982 e 2010. Foram inclu&#237;dos Ensaios Cl&#237;nicos Randomizados (ECR) que compararam o implante de stents coronarianos guiados por angiografia e USIC versus implante de stents coronarianos guiados apenas por angiografia (ANGIO). O seguimento m&#237;nimo foi de seis meses e os resultados avaliados foram eventos card&#237;acos adversos importantes (MACE), Revasculariza&#231;&#227;o da Les&#227;o-alvo (RLA) e reestenose angiogr&#225;fica. Dois revisores extra&#237;ram os dados de forma independente. Raz&#227;o de risco sum&#225;rio e intervalos de confian&#231;a de 95% (CI) foram calculados com modelos com efeitos aleat&#243;rios. A abordagem GRADE foi utilizada para determinar a qualidade geral de evid&#234;ncias para cada resultado.</p>
    <p><bold>RESULTADOS:</bold> Dos 3.631 artigos identificados, oito ECR avaliando um total de 2.341 pacientes foram inclu&#237;dos. Houve uma redu&#231;&#227;o de 27% na reestenose angiogr&#225;fica (95% IC: 3% -46%) e uma redu&#231;&#227;o de 38% em RLA (95% IC: 17% -53%) em favor de USIC versus ANGIO. No entanto, os MACE n&#227;o foram reduzidos por USIC (RR: 0,79; 95%CI: 0,61-1,03). Os dados MACE representam apenas 47% do tamanho &#243;timo de informa&#231;&#245;es necess&#225;rias para detectar com seguran&#231;a um efeito de tratamento plaus&#237;vel.</p>
    <p><bold>CONCLUS&#213;ES:</bold> Observamos que o implante de stent coronariano guiado por USIC oferece redu&#231;&#245;es significativas em RLA e reestenose angiogr&#225;fica em compara&#231;&#227;o com implante de stent guiado por angiografia, por&#233;m n&#227;o reduz casos de MACE.</p>
    <p><bold>Palavras-chave:</bold> Ultrassonografia de interven&#231;&#227;o / utiliza&#231;&#227;o, metan&#225;lise, ensaios cl&#237;nicos controlados aleat&#243;rios.</p>
    <p>
      <bold>Introdu&#231;&#227;o</bold>
    </p>
    <p>O implante de <italic>stent</italic> coronariano representa o principal m&#233;todo de revasculariza&#231;&#227;o percut&#226;nea na pr&#225;tica atual, pois reduz reestenose e eventos card&#237;acos adversos importantes (MACE)<sup>1</sup> quando comparado &#224; angioplastia com bal&#227;o. Para avaliar a adequa&#231;&#227;o da implanta&#231;&#227;o do <italic>stent</italic> durante o procedimento, pode-se usar a angiografia coronariana quantitativa e o ultrassom intracoronariano (USIC). Em compara&#231;&#227;o com o procedimento guiado por ultrassom intracoronariano, o primeiro m&#233;todo &#233; mais barato, mais f&#225;cil de executar e dispon&#237;vel em todos os centros. Por outro lado, o USIC pode fornecer informa&#231;&#245;es diagn&#243;sticas adicionais importantes n&#227;o avaliadas pela angiografia. </p>
    <p>Ap&#243;s a interven&#231;&#227;o coronariana percut&#226;nea, as taxas de reestenose s&#227;o fortemente influenciadas por um pequeno di&#226;metro luminal e a &#225;rea seccional transversal reduzida da art&#233;ria tratada. A estrutura conceitual para a hip&#243;tese de que a interven&#231;&#227;o coronariana percut&#226;nea guiada pelo USIC resultaria em melhores resultados angiogr&#225;ficos e cl&#237;nicos de longo prazo, quando comparados &#224; estrat&#233;gia padr&#227;o (procedimentos guiados apenas por angiografia), se baseia na observa&#231;&#227;o de que o exame de USIC ap&#243;s o implante de <italic>stent</italic> permite uma p&#243;s-dilata&#231;&#227;o agressiva segura e controlada com grandes di&#226;metros finais<sup>2,3</sup>. Colombo e cols.<sup>4</sup> estiveram entre os primeiros a mostrar que o implante de <italic>stent</italic> coronariano guiado por USIC &#233; seguro, vi&#225;vel e proporciona uma melhor justaposi&#231;&#227;o da pr&#243;tese &#224; parede vascular do que o resultado obtido no procedimento sem USIC. Em seu trabalho seminal, o USIC utilizado para guiar a implanta&#231;&#227;o do <italic>stent</italic> coronariano esteve associado com maior di&#226;metro luminal final e menor estenose residual em compara&#231;&#227;o com a n&#227;o utiliza&#231;&#227;o do USIC durante o procedimento, com uma redu&#231;&#227;o significativa das taxas de trombose. Estudos subsequentes apresentaram resultados semelhantes<sup>5,6</sup> e tamb&#233;m indicaram os efeitos ben&#233;ficos do USIC nos casos de MACE<sup>6,7</sup>. No entanto, outros autores n&#227;o mostraram grandes benef&#237;cios cl&#237;nicos do ultrassom intravascular guiada implante de <italic>stent</italic><sup>8,9</sup>. </p>
    <p>Na &#250;ltima d&#233;cada, uma s&#233;rie de estudos observacionais e randomizados tem investigado o benef&#237;cio do <italic>stent</italic> guiado por USIC em resultados de longo prazo, mas esses estudos possuem amostras de pequenas dimens&#245;es e resultados conflitantes. Neste estudo avaliamos o impacto da implanta&#231;&#227;o rotineira de <italic>stent</italic> coronariano guiado por USIC nos resultados cl&#237;nicos e angiogr&#225;ficos de longo prazo por meio de uma an&#225;lise sistem&#225;tica dos ensaios cl&#237;nicos randomizados.</p>
    <p>
      <bold>M&#233;todos</bold>
    </p>
    <p>
      <bold>Crit&#233;rios de elegibilidade</bold>
    </p>
    <p>Foram inclu&#237;dos Ensaios Cl&#237;nicos Randomizados (ECR) que compararam o implante de <italic>stent</italic> coronariano guiado por angiografia mais ultrassom intracoron&#225;rio (doravante designado USIC) <italic>versus</italic> implante de <italic>stent</italic> coronariano guiado apenas por angiografia (doravante designado ANGIO) em pacientes com les&#227;o coronariana sintom&#225;tica ou isquemia silenciosa, tendo avaliado os seguintes resultados: MACE, revasculariza&#231;&#227;o e/ou reestenose angiogr&#225;fica. Ensaios com acompanhamento inferior a seis meses foram exclu&#237;dos. Em casos de ensaios com v&#225;rias publica&#231;&#245;es (ou subestudos), o estudo foi inclu&#237;do apenas uma vez. </p>
    <p>
      <bold>Estrat&#233;gia de busca e sele&#231;&#227;o do estudo</bold>
    </p>
    <p>Procuramos de forma independente e duplicada, entre o per&#237;odo de 1982 e mar&#231;o de 2010, as seguintes bases de dados eletr&#244;nicas: MEDLINE (acessada pelo PubMed), Cochrane Central Register of Controlled Trials (Cochrane CENTRAL) e EMBASE. Al&#233;m disso, buscamos as refer&#234;ncias de estudos publicados. A pesquisa foi realizada em mar&#231;o de 2010 e foi composta pelos seguintes termos: "ultra-som intravascular", "ultra-som intracoron&#225;rio", "USIC", "doen&#231;a arterial coron&#225;ria", associada a uma estrat&#233;gia de alta sensibilidade para a busca de ensaios cl&#237;nicos randomizados<sup>10</sup>. As buscas foram limitadas a artigos em ingl&#234;s, espanhol e portugu&#234;s. As estrat&#233;gias detalhadas utilizadas podem ser disponibilizadas mediante solicita&#231;&#227;o. </p>
    <p>
      <bold>Extra&#231;&#227;o de dados</bold>
    </p>
    <p>Os t&#237;tulos e resumos de todos os artigos identificados pela estrat&#233;gia de busca foram avaliados independentemente por dois investigadores (G.S. e A.P.A.), de forma duplicada. Nenhum dos resumos forneceu informa&#231;&#245;es suficientes sobre os crit&#233;rios de inclus&#227;o e exclus&#227;o selecionados para a avalia&#231;&#227;o do texto integral. Na segunda fase, os mesmos revisores, de maneira independente, avaliaram os artigos na &#237;ntegra e fizeram a sua sele&#231;&#227;o de acordo com os crit&#233;rios de elegibilidade. Desacordos entre os revisores foram resolvidos por consenso, e, em casos de persist&#234;ncia do desacordo, a avalia&#231;&#227;o era feita por um terceiro revisor (A.S.Q.). Para evitar poss&#237;veis duplas contagens de pacientes inclu&#237;dos em mais de um relat&#243;rio dos mesmos autores/grupos de trabalho, foram avaliados os per&#237;odos de recrutamento de pacientes e &#225;reas de recrutamento, e os autores foram contatados para esclarecimentos. Caso n&#227;o fossem encontrados no relat&#243;rio publicado os dados necess&#225;rios, o respectivo autor era contatado para fornecer os dados faltantes. </p>
    <p>Dois revisores (G.S. e R.A.R.) conduziram, de forma independente, a extra&#231;&#227;o dos dados no que diz respeito &#224;s caracter&#237;sticas metodol&#243;gicas dos estudos, interven&#231;&#245;es e resultados por meio de formul&#225;rios padronizados; os desacordos foram resolvidos por consenso ou por um terceiro revisor (A.S.Q.). O par&#226;metro prim&#225;rio extra&#237;do foi o MACE, definido como morte, infarto do mioc&#225;rdio ou procedimento de revasculariza&#231;&#227;o [conforme estabelecido pelos autores, incluindo Interven&#231;&#227;o Coronariana Percut&#226;nea (nova ICP), Cirurgia de Revasculariza&#231;&#227;o Mioc&#225;rdica cir&#250;rgica (CRM), Revasculariza&#231;&#227;o do Vaso Alvo (RVA) ou revasculariza&#231;&#227;o da les&#227;o alvo (RLA)]. (<xref ref-type="table" rid="a112tab01">Tabela 1</xref>). Al&#233;m disso, a reestenose angiogr&#225;fica (definida como estenose de di&#226;metro &gt;50% em seis meses), bem como todos os componentes de MACE acima descritos tamb&#233;m foram analisados individualmente como par&#226;metro secund&#225;rio. </p>
    <p content-type="asset">
      <table-wrap id="a112tab01">
        <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gt01.jpg"/></table-wrap>
    </p>
    <p>
      <bold>Avalia&#231;&#227;o do risco de vi&#233;s</bold>
    </p>
    <p>A avalia&#231;&#227;o da qualidade do estudo incluiu a gera&#231;&#227;o de sequ&#234;ncia, oculta&#231;&#227;o de aloca&#231;&#227;o, cegamento dos avaliadores dos resultados, o uso da an&#225;lise inten&#231;&#227;o de tratar e descri&#231;&#227;o das perdas e exclus&#245;es. Estudos sem uma descri&#231;&#227;o clara de uma gera&#231;&#227;o sequ&#234;ncia adequada foram considerados como n&#227;o tendo atendido a esses crit&#233;rios. Considerou-se que a falta de descri&#231;&#227;o de como a lista de aloca&#231;&#227;o foi ocultada (o que pode incluir termos como "central", "baseado na web" ou "randomiza&#231;&#227;o por telefone", ou uma afirma&#231;&#227;o clara de que a lista de aloca&#231;&#227;o foi ocultada) caracterizava aus&#234;ncia de oculta&#231;&#227;o de aloca&#231;&#227;o. O uso da an&#225;lise inten&#231;&#227;o de tratar foi considerado como: confirma&#231;&#227;o sobre a avalia&#231;&#227;o de estudo de que o n&#250;mero de participantes randomizados e analisados eram id&#234;nticos, exceto para os pacientes que perderam o seguimento ou que retiraram seu consentimento para participa&#231;&#227;o no estudo. Considerou-se que estudos sem essa caracter&#237;stica n&#227;o haviam atendido esse crit&#233;rio. A avalia&#231;&#227;o da qualidade foi realizada de forma independente por dois revisores (G.S. e R.A.R.).</p>
    <p>
      <bold>An&#225;lise de dados</bold>
    </p>
    <p>Os &#237;ndices de risco sum&#225;rio (RR) e intervalos de confian&#231;a de 95% (CI) foram calculados com modelos de efeito aleat&#243;rio (Mantel-Haenszel) de acordo com o n&#250;mero de eventos relatados na an&#225;lise de inten&#231;&#227;o de tratar dos estudos originais ou subestudos. Para o resultado de reestenose angiogr&#225;fica, foi utilizada a an&#225;lise de caso dispon&#237;vel<sup>11</sup>. Para esse resultado, a an&#225;lise de sensibilidade foi realizada considerando a an&#225;lise de inten&#231;&#227;o de tratar. A heterogeneidade estat&#237;stica dos efeitos de tratamento entre os estudos foi avaliada pelo teste de Cochran Q e a inconsist&#234;ncia pelo teste I<sup>2</sup>, em que se considerou que valores acima de 25% e 50% indicavam heterogeneidade moderada e alta, respectivamente<sup>12</sup>. Todas as an&#225;lises foram realizadas utilizando o Review Manager vers&#227;o 5.0 (Colabora&#231;&#227;o Cochrane)<sup>13</sup>.</p>
    <p>As an&#225;lises de sensibilidade foram realizadas considerando as caracter&#237;sticas metodol&#243;gicas dos estudos (an&#225;lise de inten&#231;&#227;o de tratar, gera&#231;&#227;o adequada de sequ&#234;ncia, oculta&#231;&#227;o da aloca&#231;&#227;o e cegamento dos avaliadores de resultados). </p>
    <p>Os autores tinham pleno acesso aos dados e assumiram total responsabilidade por sua integridade. Todos os autores deram sua aprova&#231;&#227;o para a apresenta&#231;&#227;o do manuscrito final. </p>
    <p>
      <bold>Resumo dos resultados</bold>
    </p>
    <p>Apresentamos a qualidade geral das evid&#234;ncias usando a abordagem GRADE conforme recomendado pelo Cochrane Handbook para Revis&#245;es Sistem&#225;ticas de Interven&#231;&#245;es. Para cada resultado espec&#237;fico, a qualidade das evid&#234;ncias baseou-se em cinco fatores: (1) limita&#231;&#245;es do desenho do estudo; (2) consist&#234;ncia dos resultados; (3) objetividade; (4) precis&#227;o e (5) potencial de vi&#233;s de publica&#231;&#227;o. A qualidade foi reduzida em um n&#237;vel para cada um dos fatores n&#227;o atendidos. A abordagem GRADE resultou em quatro n&#237;veis de qualidade da evid&#234;ncia: alta, moderada, baixa e muito baixa<sup>14</sup>. O software GRADE Profiler (vers&#227;o 3.2) foi utilizado<sup>15</sup>. </p>
    <p>
      <bold>Confiabilidade e conclusividade dos dados</bold>
    </p>
    <p>O dimensionamento ideal das informa&#231;&#245;es de evid&#234;ncias dispon&#237;veis sobre o implante de <italic>stent</italic> por USIC <italic>versus</italic> ANGIO baseou-se no resultado composto de MACE<sup>16,17</sup>. O tamanho de amostra necess&#225;rio para uma meta-an&#225;lise confi&#225;vel e conclusiva seria o tamanho necess&#225;rio para um ECR &#250;nico ideal alimentado, ent&#227;o calculamos o tamanho de amostra ideal para a nossa meta-an&#225;lise. Utilizamos essa dimens&#227;o ideal de informa&#231;&#245;es como uma maneira de determinar se as evid&#234;ncias em nossa meta-an&#225;lise eram confi&#225;veis e conclusivas.</p>
    <p>
      <bold>Resultados</bold>
    </p>
    <p>
      <bold>Descri&#231;&#227;o dos estudos</bold>
    </p>
    <p>De 3.631 cita&#231;&#245;es potencialmente relevantes recuperadas de bancos de dados eletr&#244;nicos e pesquisas de listas de refer&#234;ncia, oito RCT<sup>5-9,18-20</sup> preencheram os crit&#233;rios de inclus&#227;o. A <xref ref-type="fig" rid="a112fig01">figura 1</xref> mostra o diagrama de fluxo de estudos nesta revis&#227;o. Os estudos inclu&#237;dos tinham um total de 2.397 pacientes (1.182 no grupo de implante de <italic>stent</italic> guiado por USIC). A <xref ref-type="table" rid="a112tab01">tabela 1</xref> resume as caracter&#237;sticas desses estudos. </p>
    <p content-type="asset">
      <fig id="a112fig01">
        <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gf01.jpg"/></fig>
    </p>
    <p>
      <bold>Risco de vi&#233;s</bold>
    </p>
    <p>Dos estudos inclu&#237;dos, 37% apresentaram gera&#231;&#227;o de sequ&#234;ncia adequada, 62% relataram oculta&#231;&#227;o de aloca&#231;&#227;o, 62% haviam cegado a avalia&#231;&#227;o dos resultados, 87% descreveram perdas de seguimento e exclus&#245;es, e 100% utilizaram o princ&#237;pio da an&#225;lise de inten&#231;&#227;o de tratar para an&#225;lises estat&#237;sticas (<xref ref-type="table" rid="a112tab02">Tabela 2</xref>).</p>
    <p content-type="asset">
      <table-wrap id="a112tab02">
        <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gt02.jpg"/></table-wrap>
    </p>
    <p>
      <bold>Efeitos das interven&#231;&#245;es</bold>
    </p>
    <p>
      <bold>Par&#226;metro prim&#225;rio: eventos card&#237;acos adversos importantes</bold>
    </p>
    <p>Sete artigos<sup>5-9,18,19</sup> (n = 2,186) avaliaram MACE (<xref ref-type="fig" rid="a112fig02">Figura 2</xref>). O implante de <italic>stent</italic> guiado por USIC esteve associado a uma redu&#231;&#227;o n&#227;o significativa de 21% de MACE em compara&#231;&#227;o com o implante de <italic>stent</italic> guiado pela ANGIO (RR: 0,79; 95% IC: 0,61-1,03; I<sup>2</sup>: 44%). Com base na abordagem GRADE, a qualidade das evid&#234;ncias para este resultado foi considerada baixa, principalmente por causa da imprecis&#227;o e inconsist&#234;ncia dos resultados (<xref ref-type="table" rid="a112tab03">Tabela 3</xref>). </p>
    <p content-type="asset">
      <fig id="a112fig02">
        <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gf02.jpg"/></fig>
    </p>
    <p content-type="asset">
      <table-wrap id="a112tab03">
        <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gt03.jpg"/></table-wrap>
    </p>
    <p>Analisando-se os resultados de forma individual, observamos que o implante de <italic>stent</italic> guiado por USIC estava associado a um aumento n&#227;o significativo de 35% na mortalidade por todas as causas<sup>5-9,18-20</sup> (RR: 1.35; 95% IC: 0.73-2.48; I<sup>2</sup>: 0%) e uma redu&#231;&#227;o significativa de 39% no infarto do mioc&#225;rdio<sup>5-9,18,19</sup> (RR: 0.61; 95% IC: 0.29-1.26; I<sup>2</sup>: 37%) em compara&#231;&#227;o com o implante de <italic>stent</italic> guiado por ANGIO (<xref ref-type="fig" rid="a112fig02">fig. 2</xref>). Com base na abordagem GRADE, a qualidade geral das evid&#234;ncias apresentou-se moderada pela mortalidade por todas as causas (com base na imprecis&#227;o dos resultados) e baixa pelo infarto do mioc&#225;rdio (com base na imprecis&#227;o e na inconsist&#234;ncia dos resultados) (<xref ref-type="table" rid="a112tab03">Tabela 3</xref>).</p>
    <p>
      <bold>Par&#226;metros secund&#225;rios</bold>
    </p>
    <p>
      <bold>Reestenose angiogr&#225;fica</bold>
    </p>
    <p>A <xref ref-type="fig" rid="a112fig03">figura 3</xref> mostra uma compara&#231;&#227;o entre o implante de <italic>stent</italic> guiado por USIC <italic>versus </italic>ANGIO em compara&#231;&#227;o com a reestenose angiogr&#225;fica<sup>5-8,18,20</sup>. A estrat&#233;gia guiada por USIC determinou uma redu&#231;&#227;o de 27% na reestenose angiogr&#225;fica (RR: 0.73; 95% IC: 0.54-0.97; I<sup>2</sup>: 51%). O n&#250;mero de pacientes que precisavam de tratamento (NNT) iara evitar uma reestenose angiogr&#225;fica foi 11. De acordo com a abordagem GRADE, a qualidade das evid&#234;ncias para esse resultado apresentou-se moderada com base na inconsist&#234;ncia dos resultados obtidos nessa an&#225;lise (<xref ref-type="table" rid="a112tab03">Tabela 3</xref>). </p>
    <p content-type="asset">
      <fig id="a112fig03">
        <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gf03.jpg"/></fig>
    </p>
    <p>
      <bold>Revasculariza&#231;&#227;o de les&#227;o alvo e revasculariza&#231;&#227;o de vaso alvo</bold>
    </p>
    <p>Cinco ECR<sup>5,6,9,18,19</sup> avaliaram RLA e dois artigos<sup>5,7</sup> avaliaram RVA (<xref ref-type="fig" rid="a112fig04">Figura 4</xref>). Houve uma redu&#231;&#227;o de 38% nos casos de RLA (RR: 0,62; 95% IC: 0,47-0,83; I<sup>2</sup>: 0%) em pacientes submetidos a implante de <italic>stent</italic> guiado por USIC <italic>versus</italic> ANGIO. O NNT para prevenir uma RLA era 20. Com base na abordagem GRADE, as evid&#234;ncias para RLA era de alta qualidade (<xref ref-type="table" rid="a112tab03">Tabela 3</xref>). Al&#233;m disso, houve uma redu&#231;&#227;o n&#227;o significativa de 42% nos casos de RVA (RR: 0,58; 95% IC: 0,30-1,12; I<sup>2</sup>: 0%) em favor do USIC. De acordo com a abordagem GRADE, havia evid&#234;ncias de qualidade moderada para esse resultado com base na imprecis&#227;o dos resultados (<xref ref-type="table" rid="a112tab03">Tabela 3</xref>).</p>
    <p content-type="asset">
      <fig id="a112fig04">
        <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gf04.jpg"/></fig>
    </p>
    <p>
      <bold>Novos procedimentos de interven&#231;&#227;o coron&#225;ria percut&#226;nea e cirurgia de revasculariza&#231;&#227;o mioc&#225;rdica</bold>
    </p>
    <p>Dois artigos<sup>7,8</sup> avaliaram nova ICP e tr&#234;s avaliaram a cirurgia de revasculariza&#231;&#227;o mioc&#225;rdica<sup>7,9</sup>. O implante de <italic>stent</italic> guiado por USIC determinou uma redu&#231;&#227;o n&#227;o significativa de 43% nos casos de re-PCI (RR: 0,57; 95% IC: 0,16-2,01; I<sup>2</sup>: 84%) e uma redu&#231;&#227;o n&#227;o significativa de 4% nos casos de cirurgia de revasculariza&#231;&#227;o mioc&#225;rdica (RR: 0,96; 95% IC: 0,52-1,77; I<sup>2</sup>: 0%) em compara&#231;&#227;o com o implante de <italic>stent</italic> guiado por ANGIO. Com base na abordagem GRADE, re-PCI e cirurgia de revasculariza&#231;&#227;o mioc&#225;rdica apresentaram evid&#234;ncias de qualidade muito baixa e moderada, respectivamente (<xref ref-type="table" rid="a112tab03">Tabela 3</xref>).</p>
    <p>
      <bold>Confiabilidade e conclusividade dos dados</bold>
    </p>
    <p>Para determinar a dimens&#227;o ideal das informa&#231;&#245;es, assumimos uma taxa de eventos nos controles de 20% (a taxa de evento nos controles em nossa meta-an&#225;lise para MACE) e uma redu&#231;&#227;o do risco relativo em 20%, com poder de 90% e &#945; bilateral de 0,01. Esse c&#225;lculo indica que a dimens&#227;o ideal de informa&#231;&#245;es necess&#225;rias para detectar com seguran&#231;a um efeito de tratamento plaus&#237;vel para esse resultado &#233; de no m&#237;nimo 4.655 pacientes. </p>
    <p>
      <bold>An&#225;lises de sensibilidade</bold>
    </p>
    <p>As an&#225;lises de sensibilidade foram realizadas para os resultados, MACE e reestenose angiogr&#225;fica. </p>
    <p>Para MACE, n&#227;o foi realizada an&#225;lise de sensibilidade considerando-se a an&#225;lise de inten&#231;&#227;o de tratar, devido ao fato de que todos os estudos inclu&#237;dos nessa meta-an&#225;lise inclu&#237;ram essa caracter&#237;stica metodol&#243;gica. Sobre oculta&#231;&#227;o da aloca&#231;&#227;o, os estudos de Frey e cols.<sup>18</sup> e Oemrawsingh e cols.<sup>6</sup> foram removidos da meta-an&#225;lise pois n&#227;o atendiam ao crit&#233;rio, embora o resultado da an&#225;lise permanecesse inalterado (RR: 0,85, 95% IC: 0,64 -1,13; I<sup>2</sup>: 35%). Tamb&#233;m observamos o mesmo padr&#227;o em rela&#231;&#227;o &#224; descri&#231;&#227;o adequada da sequ&#234;ncia de randomiza&#231;&#227;o, quando, ap&#243;s a retirada dos estudos<sup>5,6,8,19</sup> que n&#227;o atendiam a essa caracter&#237;stica, n&#227;o havia altera&#231;&#227;o no resultado da an&#225;lise (RR: 0,83, 95% IC: 0,63-1,09, I<sup>2</sup>: 36%). Al&#233;m disso, considerando o cegamento dos avaliadores dos resultados, dois artigos<sup>7,19</sup> foram retirados da meta-an&#225;lise e n&#227;o houve diferen&#231;a no resultado (RR: 0,81, IC 95%: 0,59-1,11; I<sup>2</sup>: 52%). Com a retirada do estudo que utilizou <italic>stents</italic> farmacol&#243;gicos<sup>19</sup> a partir da an&#225;lise, nenhuma mudan&#231;a foi observada nos resultados (RR: 0,76, IC 95%: 0,57-1,03; I<sup>2</sup>: 53%). </p>
    <p>O resultado de reestenose angiogr&#225;fica foi apresentado utilizando-se a an&#225;lise de caso dispon&#237;vel. Portanto, foi realizada an&#225;lise de sensibilidade utilizando a an&#225;lise de inten&#231;&#227;o de tratar por meio da imputa&#231;&#227;o de dados<sup>11</sup>. Para esse resultado, a n&#227;o utiliza&#231;&#227;o da an&#225;lise de inten&#231;&#227;o de tratar por parte dos autores n&#227;o influenciou o resultado da meta-an&#225;lise (RR: 0,80, 95% IC: 0,64-0,98; I<sup>2</sup>: 45%).</p>
    <p>
      <bold>Discuss&#227;o</bold>
    </p>
    <p>No presente artigo, realizamos uma revis&#227;o sistem&#225;tica e uma meta-an&#225;lise para avaliar o impacto do implante de <italic>stents</italic> coronarianos guiados por USIC em resultados de longo prazo. Nossos resultados demonstraram uma redu&#231;&#227;o significativa de 38% nos casos de RLA e 27% na reestenose angiogr&#225;fica com essa estrat&#233;gia, mas nenhuma diferen&#231;a estatisticamente significativa no total de casos de MACE, &#243;bito ou infarto do mioc&#225;rdio. </p>
    <p>Na pr&#225;tica de cardiologia intervencionista atual, a penetra&#231;&#227;o do USIC apresentou-se bastante heterog&#234;nea, de acordo com a experi&#234;ncia e prefer&#234;ncia de cada centro e cada cirurgi&#227;o. As mais recentes Diretrizes para Interven&#231;&#227;o Coronariana Percut&#226;nea atribuem a recomenda&#231;&#227;o classe IIa n&#237;vel de evid&#234;ncia B para o implante de <italic>stent</italic> coronariano guiado por USIC<sup>21</sup>. Nossos resultados podem servir para fortalecer essa recomenda&#231;&#227;o, tendo em vista que reestenoses angiogr&#225;ficas e cl&#237;nicas foram significativamente reduzidas com o emprego de USIC. </p>
    <p>O custo dessa tecnologia, contudo, tamb&#233;m deve ser levado em conta. Considerando o NNT para evitar uma RLA (20) e o custo adicional para incluir o USIC em um procedimento de ICP (em torno de R$ 2 mil), seriam necess&#225;rios R$ 40 mil para evitar uma RLA. </p>
    <p>Tamb&#233;m &#233; importante considerar se o USIC deve ser feito em todos os pacientes, ou apenas naqueles com alto risco de reestenose. A nossa an&#225;lise n&#227;o fornece nenhuma informa&#231;&#227;o sobre a exist&#234;ncia de subgrupos com maiores benef&#237;cios, por&#233;m sugere que pacientes com maior complexidade podem se beneficiar mais. A rela&#231;&#227;o custo-benef&#237;cio das interven&#231;&#245;es destinadas a reduzir a repeti&#231;&#227;o das revasculariza&#231;&#245;es tamb&#233;m &#233; favor&#225;vel naqueles com elevados riscos basais de reestenose<sup>22</sup>. </p>
    <p>Atualmente, os<italic> stents</italic> farmacol&#243;gicos s&#227;o recomendados para a redu&#231;&#227;o da reestenoses/reoclus&#227;o, contanto que n&#227;o haja contraindica&#231;&#227;o para terapias antiplaquet&#225;rias duplas prolongadas<sup>23-26</sup>. Nosso estudo n&#227;o abordou a quest&#227;o sobre se o implante rotineiro de <italic>stent</italic> guiado por USIC &#233; melhor do que a angiografia isolada quando um <italic>stent</italic> farmacol&#243;gico &#233; implantado<sup>19</sup>. Embora alguns preditores da reestenose a implanta&#231;&#227;o de <italic>stents</italic> farmacol&#243;gicos ou <italic>stents</italic> de metal simples sejam similares<sup>27,28</sup>, a extrapola&#231;&#227;o dos dados de uma popula&#231;&#227;o para outra pode n&#227;o ser apropriada. Contudo, deve-se considerar nos nossos resultados que nem todos os pacientes, na pr&#225;tica di&#225;ria, ser&#227;o bons candidatos para receber um <italic>stent</italic> farmacol&#243;gico. Pacientes com contraindica&#231;&#245;es ou baixa ades&#227;o &#224; terapia antiplaquet&#225;ria dupla de longo prazo, cirurgia n&#227;o card&#237;aca planejada e comorbidades associadas com risco elevado de hemorragia representam algumas dessas situa&#231;&#245;es<sup>24,29-32</sup>. </p>
    <p>As an&#225;lises de sensibilidade realizadas n&#227;o alteraram os resultados globais da meta-an&#225;lise. Frey e cols.<sup>18</sup> realizaram um estudo cl&#237;nico randomizado com implante de <italic>stent</italic> provis&#243;rio guiado por USIC <italic>versus </italic>tratamento convencional, mas nem todos os pacientes receberam o implante de <italic>stent</italic>. Decidimos incluir esse ensaio nessa meta-an&#225;lise, e a an&#225;lise de sensibilidade que promoveu a retirada desse estudo n&#227;o alterou os resultados para MACE, mortalidade, infarto do mioc&#225;rdio, reestenose angiogr&#225;fica e RLA. O estudo realizado por Jakabcin e cols.<sup>19</sup> adotou implante de rotina de <italic>stent</italic> farmacol&#243;gico por protocolo. Sendo assim, tamb&#233;m decidimos incluir os dados desse ensaio. Na an&#225;lise de sensibilidade onde esse estudo foi removido, os resultados n&#227;o se alteraram. </p>
    <p>Nosso estudo apresenta diversos pontos fortes do ponto de vista metodol&#243;gico, a saber: 1. Perguntas direcionadas de revis&#227;o; 2. Pesquisa bibliogr&#225;fica abrangente e sistem&#225;tica; e 3. A colabora&#231;&#227;o de uma equipe multidisciplinar de cardiologistas intervencionistas, pesquisadores de sa&#250;de e metod&#243;logos, que utilizaram crit&#233;rios de elegibilidade expl&#237;citos e reprodut&#237;veis e duplicaram decis&#245;es de elegibilidade altamente independentes e reprodut&#237;veis, al&#233;m de abstra&#231;&#245;es de dados. A meta-an&#225;lise foi utilizada para expressar quantitativamente os resultados obtidos e avaliar a qualidade das evid&#234;ncias para cada resultado analisado. Outro ponto forte importante deste relat&#243;rio &#233; que calculamos o tamanho da amostra (n&#250;mero ideal de informa&#231;&#245;es) necess&#225;rio para a nossa meta-an&#225;lise de forma a determinar se as evid&#234;ncias apresentadas em nossa meta-an&#225;lise eram confi&#225;veis e conclusivas. </p>
    <p>Casella e cols.<sup>33</sup> tamb&#233;m conduziram uma meta-an&#225;lise nesse campo, que foi publicada h&#225; muitos anos. O trabalho consistia apenas de cinco ECR (n = 1.883), ao passo que a presente revis&#227;o consistiu de tr&#234;s ECR adicionais, totalizando oito ensaios cl&#237;nicos (n = 2.341). Considerando apenas a an&#225;lise os ECR da primeira revis&#227;o<sup>33</sup>, o implante de <italic>stent</italic> guiado por USIC n&#227;o reduziu os casos de MACE (OR: 0,82, 95% IC: 0,64-1,04), &#243;bitos (OR: 1,27, 95% IC: 0,47-3,42) ou infarto do mioc&#225;rdio (OR: 0,96, 95% IC: 0,59-1,56), semelhante aos resultados do presente estudo. No entanto, n&#227;o observamos taxas menores de reestenose com implante de <italic>stent</italic> guiado por USIC em compara&#231;&#227;o ao implante de <italic>stent</italic> guiado por angiografia, o que n&#227;o foi reportado por Casella e cols.<sup>33</sup> (OR: 0,81, 95% IC: 0,62-1,06). Deve-se ressaltar que a nossa revis&#227;o sistem&#225;tica incluiu apenas ERC e apresentou maior n&#250;mero de estudos em compara&#231;&#227;o com o estudo de Casella e cols.<sup>33</sup>, o que deve ter contribu&#237;do para uma melhor estimativa dos dados encontrados pelo nosso grupo.</p>
    <p>Parise e cols.<sup>34</sup> tamb&#233;m realizaram uma revis&#227;o sistem&#225;tica desse t&#243;pico recentemente. Em seu artigo, os resultados relacionados a reestenose foram semelhantes, por&#233;m os autores tamb&#233;m encontraram um benef&#237;cio do USIC na redu&#231;&#227;o dos casos de MACE (OR 0,72, 95% IC 0,52-0,99), o que n&#227;o foi apresentado na nossa an&#225;lise. A principal diferen&#231;a entre essas duas meta-an&#225;lises &#233; a omiss&#227;o dos dados de casos de MACE no ensaio RESIST em nossos c&#225;lculos<sup>20</sup>, o que, em sua publica&#231;&#227;o, n&#227;o apresentou a defini&#231;&#227;o de MACE. De fato, uma publica&#231;&#227;o secund&#225;ria do ensaio sugere que os n&#250;meros usados por Parise e cols.<sup>34</sup> em seu artigo inclu&#237;ram apenas revasculariza&#231;&#227;o e &#243;bito, o que n&#227;o insere na nossa defini&#231;&#227;o (e na defini&#231;&#227;o de outros ensaios) de MACE, que inclu&#237;a infarto do mioc&#225;rdio<sup>35</sup>. Ademais, a nossa an&#225;lise baseada na abordagem GRADE sugere evid&#234;ncias de baixa qualidade para esse resultado, e o nosso c&#225;lculo do n&#250;mero ideal de informa&#231;&#245;es mostra que a quest&#227;o sobre o benef&#237;cio do USIC em rela&#231;&#227;o a MACE est&#225; longe de ser respondida de forma adequada.</p>
    <p>Algumas limita&#231;&#245;es presentes no nosso estudo merecem ser destacadas. Primeiramente, a maioria dos estudos inclu&#237;dos na nossa revis&#227;o sistem&#225;tica podem n&#227;o representar a pr&#225;tica de ICP atual, tendo em vista que os <italic>stents</italic> utilizados nos ensaios s&#227;o os <italic>stents</italic> empregados atualmente. T&#233;cnicas de ICP mudaram consideravelmente, os cardiologistas intervencionistas possuem mais experi&#234;ncia hoje do que antes, a terapia antiplaquet&#225;ria &#233; mais agressiva e a complexidade dos casos aumentou<sup>25</sup>. Al&#233;m disso, a dimens&#227;o da amostra n&#227;o era a ideal, tendo em vista que o total de dados dispon&#237;veis sobre MACE representa apenas 47% do n&#250;mero ideal de informa&#231;&#245;es necess&#225;rias para detectar, com confiabilidade, um efeito de tratamento plaus&#237;vel. No entanto, com mais estudos e com um n&#250;mero maior de pacientes, o implante de <italic>stent</italic> guiado por USIC pode reduzir significativamente os casos de MACE, tendo em vista que o valor de p para esta an&#225;lise foi 0,08. </p>
    <p>
      <bold>Conclus&#245;es</bold>
    </p>
    <p>Esta revis&#227;o sistem&#225;tica e meta-an&#225;lise demonstra que o implante de <italic>stent</italic> guiado por USIC reduz a reestenose angiogr&#225;fica e RLA em compara&#231;&#227;o com o implante de <italic>stent</italic> guiado por angiografia, por&#233;m n&#227;o reduz os casos de MACE. Esses dados podem fornecer um suporte maior ao uso de USIC, mas a realiza&#231;&#227;o de ECRs de maior escala e de alta qualidade &#233; necess&#225;ria a fim de elucidar o poss&#237;vel benef&#237;cio do USIC em rela&#231;&#227;o aos hard endpoints (desfechos duros).</p>
    <p>
      <bold>Potencial Conflito de Interesses</bold>
    </p>
    <p>Declaro n&#227;o haver conflito de interesses pertinentes.</p>
    <p>
      <bold>Fontes de Financiamento</bold>
    </p>
    <p>O presente estudo foi parcialmente financiado pelo CNPq e CAPES.</p>
    <p>
      <bold>Vincula&#231;&#227;o Acad&#234;mica</bold>
    </p>
    <p>N&#227;o h&#225; vincula&#231;&#227;o deste estudo a programas de p&#243;s-gradua&#231;&#227;o.</p>
    <p>
      <fn id="end" fn-type="corresp">
        <label>
          <bold>Correspond&#234;ncia:</bold>
        </label>
        <p> Graciele Sbruzzi</p>
        <p> Rua Padre Antonio Vieira, 9 / 306, Santo Antonio</p>
        <p> 90640-060 - Porto Alegre, RS, Brasil </p>
        <p> E-mail: </p>
        <p><email xlink:href="graci.10@bol.com.br">graci.10@bol.com.br</email>, </p>
        <p>
          <email xlink:href="graci_sbruzzi@hotmail.com">graci_sbruzzi@hotmail.com</email>
        </p>
      </fn>
    </p>
    <p>Artigo recebido em 06/04/11; revisado recebido em 25/05/11; aceito em 14/06/11.</p>
    <p>Este artigo sofreu altera&#231;&#245;es por solicita&#231;&#227;o do editor em Jan/2012 conforme ERRATA publicada no Volume 98 N&#250;mero 1 do peri&#243;dico. (<ext-link ext-link-type="uri" xlink:href="http://www.scielo.br/pdf/abc/v98n1/v98n1a21.pdf">http://www.scielo.br/pdf/abc/v98n1/v98n1a21.pdf</ext-link>)</p>
  </body>
  <back>
    <ref-list>
      <ref id="B1">
        <mixed-citation>1. Hannan EL, Racz MJ, Arani DT, McCallister BD, Walford G, Ryan TJ. A comparison of short- and long-term outcomes for balloon angioplasty and coronary stent placement. J Am Coll Cardiol. 2000;36(2):395-403.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>A comparison of short- and long-term outcomes for balloon angioplasty and coronary stent placement</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>395</fpage>
          <lpage>403</lpage>
          <issue>2</issue>
          <volume>36</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Hannan</surname>
              <given-names>EL</given-names>
            </name>
            <name>
              <surname>Racz</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Arani</surname>
              <given-names>DT</given-names>
            </name>
            <name>
              <surname>McCallister</surname>
              <given-names>BD</given-names>
            </name>
            <name>
              <surname>Walford</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Ryan</surname>
              <given-names>TJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Mudra H, Klauss V, Blasini R, Kroetz M, Rieber J, Regar E, et al. Ultrasound guidance of Palmaz-Schatz intracoronary stenting with a combined intravascular ultrasound balloon catheter. Circulation. 1994;90(3):1252-61.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Ultrasound guidance of Palmaz-Schatz intracoronary stenting with a combined intravascular ultrasound balloon catheter</article-title>
          <source>Circulation</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>1252</fpage>
          <lpage>61</lpage>
          <issue>3</issue>
          <volume>90</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Mudra</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Klauss</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Blasini</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Kroetz</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Rieber</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Regar</surname>
              <given-names>E</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. Serruys PW, van Der Giessen W, Garcia E, Macaya C, Colombo A, Rutsch W, et al. Clinical and Angiographic Results with the Multi-Link Stent Implanted under Intravascular Ultrasound Guidance (West-2 Study). J Invasive Cardiol. 1998;10(Suppl B):20B-7B.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Clinical and Angiographic Results with the Multi-Link Stent Implanted under Intravascular Ultrasound Guidance (West-2 Study)</article-title>
          <source>J Invasive Cardiol</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>20B</fpage>
          <lpage>7B</lpage>
          <volume>10</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Serruys</surname>
              <given-names>PW</given-names>
            </name>
            <name>
              <surname>van Der Giessen</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Garcia</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Macaya</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Colombo</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Rutsch</surname>
              <given-names>W</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Colombo A, Hall P, Nakamura S, Almagor Y, Maiello L, Martini G, et al. Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation. 1995;91(6):1676-88.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance</article-title>
          <source>Circulation</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>1676</fpage>
          <lpage>88</lpage>
          <issue>6</issue>
          <volume>91</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Colombo</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Hall</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Nakamura</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Almagor</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Maiello</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Martini</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. Gil RJ, Pawlowski T, Dudek D, Horszczaruk G, Zmudka K, Lesiak M, et al. Comparison of angiographically guided direct stenting technique with direct stenting and optimal balloon angioplasty guided with intravascular ultrasound. The multicenter, randomized trial results. Am Heart J. 2007;154(4):669-75.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Comparison of angiographically guided direct stenting technique with direct stenting and optimal balloon angioplasty guided with intravascular ultrasound: The multicenter, randomized trial results</article-title>
          <source>Am Heart J</source>
          <date>
            <year>2007</year>
          </date>
          <fpage>669</fpage>
          <lpage>75</lpage>
          <issue>4</issue>
          <volume>154</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Gil</surname>
              <given-names>RJ</given-names>
            </name>
            <name>
              <surname>Pawlowski</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Dudek</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Horszczaruk</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Zmudka</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Lesiak</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B6">
        <mixed-citation>6. Oemrawsingh PV, Mintz GS, Schalij MJ, Zwinderman AH, Jukema JW, van der Wall EE. Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: final results of a randomized comparison with angiographic guidance (TULIP Study). Circulation. 2003;107(1):62-7.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: final results of a randomized comparison with angiographic guidance (TULIP Study)</article-title>
          <source>Circulation</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>62</fpage>
          <lpage>7</lpage>
          <issue>1</issue>
          <volume>107</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Oemrawsingh</surname>
              <given-names>PV</given-names>
            </name>
            <name>
              <surname>Mintz</surname>
              <given-names>GS</given-names>
            </name>
            <name>
              <surname>Schalij</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Zwinderman</surname>
              <given-names>AH</given-names>
            </name>
            <name>
              <surname>Jukema</surname>
              <given-names>JW</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B7">
        <mixed-citation>7. Gaster AL, Slothuus Skjoldborg U, Larsen J, Korsholm L, von Birgelen C, Jensen S, et al. Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study. Heart. 2003;89(9):1043-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study</article-title>
          <source>Heart</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>1043</fpage>
          <lpage>9</lpage>
          <issue>9</issue>
          <volume>89</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Gaster</surname>
              <given-names>AL</given-names>
            </name>
            <name>
              <surname>Slothuus Skjoldborg</surname>
              <given-names>U</given-names>
            </name>
            <name>
              <surname>Larsen</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Korsholm</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>von Birgelen</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Jensen</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B8">
        <mixed-citation>8. Mudra H, di Mario C, de Jaegere P, Figulla HR, Macaya C, Zahn R, et al. Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study). Circulation. 2001;104(12):1343-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study)</article-title>
          <source>Circulation</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>1343</fpage>
          <lpage>9</lpage>
          <issue>12</issue>
          <volume>104</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Mudra</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>di Mario</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>de Jaegere</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Figulla</surname>
              <given-names>HR</given-names>
            </name>
            <name>
              <surname>Macaya</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Zahn</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B9">
        <mixed-citation>9. Russo RJ, Silva PD, Teirstein PS, Attubato MJ, Davidson CJ, DeFranco AC, et al. A randomized controlled trial of angiography versus intravascular ultrasound-directed bare-metal coronary stent placement (the AVID Trial). Circ Cardiovasc Interv. 2009;2(2):113-23.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>A randomized controlled trial of angiography versus intravascular ultrasound-directed bare-metal coronary stent placement (the AVID Trial)</article-title>
          <source>Circ Cardiovasc Interv</source>
          <date>
            <year>2009</year>
          </date>
          <fpage>113</fpage>
          <lpage>23</lpage>
          <issue>2</issue>
          <volume>2</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Russo</surname>
              <given-names>RJ</given-names>
            </name>
            <name>
              <surname>Silva</surname>
              <given-names>PD</given-names>
            </name>
            <name>
              <surname>Teirstein</surname>
              <given-names>PS</given-names>
            </name>
            <name>
              <surname>Attubato</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Davidson</surname>
              <given-names>CJ</given-names>
            </name>
            <name>
              <surname>DeFranco</surname>
              <given-names>AC</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B10">
        <mixed-citation>10. Robinson KA, Dickersin K. Development of a highly sensitive search strategy for the retrieval of reports of controlled trials using PubMed. Int J Epidemiol. 2002;31(1):150-3.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Development of a highly sensitive search strategy for the retrieval of reports of controlled trials using PubMed</article-title>
          <source>Int J Epidemiol</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>150</fpage>
          <lpage>3</lpage>
          <issue>1</issue>
          <volume>31</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Robinson</surname>
              <given-names>KA</given-names>
            </name>
            <name>
              <surname>Dickersin</surname>
              <given-names>K</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B11">
        <mixed-citation>11. Higgins JPT, Green S. Cochrane handbook for systematic reviews of interventions. 5<sup>th</sup> ed. New York: John Wiley &amp; Sons; 2008. (Cochrane Book Series).</mixed-citation>
        <element-citation publication-type="book">
          <source>Cochrane handbook for systematic reviews of interventions</source>
          <date>
            <year>2008</year>
          </date>
          <person-group person-group-type="author">
            <name>
              <surname>Higgins</surname>
              <given-names>JPT</given-names>
            </name>
            <name>
              <surname>Green</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B12">
        <mixed-citation>12. Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. 2003;327(7414):557-60.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Measuring inconsistency in meta-analyses</article-title>
          <source>BMJ</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>557</fpage>
          <lpage>60</lpage>
          <issue>7414</issue>
          <volume>327</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Higgins</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>Thompson</surname>
              <given-names>SG</given-names>
            </name>
            <name>
              <surname>Deeks</surname>
              <given-names>JJ</given-names>
            </name>
            <name>
              <surname>Altman</surname>
              <given-names>DG</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B13">
        <mixed-citation>13. Cochrane collaboration. [Accessed on 2011 Feb. 3]. Available from: <ext-link ext-link-type="uri" xlink:href="http://www.cochrane.org">http://www.cochrane.org</ext-link></mixed-citation>
        <element-citation publication-type="book">
          <source>Cochrane collaboration</source>
        </element-citation>
      </ref>
      <ref id="B14">
        <mixed-citation>14. Guyatt GH, Oxman AD, Vist GE, Kunz R, Falck-Ytter Y, Alonso-Coello P, et al. GRADE: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ. 2008;336(7650):924-6.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>GRADE: an emerging consensus on rating quality of evidence and strength of recommendations</article-title>
          <source>BMJ</source>
          <date>
            <year>2008</year>
          </date>
          <fpage>924</fpage>
          <lpage>6</lpage>
          <issue>7650</issue>
          <volume>336</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Guyatt</surname>
              <given-names>GH</given-names>
            </name>
            <name>
              <surname>Oxman</surname>
              <given-names>AD</given-names>
            </name>
            <name>
              <surname>Vist</surname>
              <given-names>GE</given-names>
            </name>
            <name>
              <surname>Kunz</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Falck-Ytter</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Alonso-Coello</surname>
              <given-names>P</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B15">
        <mixed-citation>15. GRADE pro. [Computer program]. Version 3.2 for Windows. Jan Brozek, Andrew Oxman, Holger Sch&#252;nemann.</mixed-citation>
        <element-citation publication-type="book">
          <source>GRADE pro</source>
          <person-group person-group-type="author">
            <name>
              <surname>Brozek</surname>
              <given-names>Jan</given-names>
            </name>
            <name>
              <surname>Oxman</surname>
              <given-names>Andrew</given-names>
            </name>
            <name>
              <surname>Sch&#252;nemann</surname>
              <given-names>Holger</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B16">
        <mixed-citation>16. Devereaux PJ, Beattie WS, Choi PT, Badner NH, Guyatt GH, Villar JC, et al. How strong is the evidence for the use of perioperative beta blockers in non-cardiac surgery? Systematic review and meta-analysis of randomised controlled trials. BMJ. 2005;331(7512):313-21.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>How strong is the evidence for the use of perioperative beta blockers in non-cardiac surgery: Systematic review and meta-analysis of randomised controlled trials</article-title>
          <source>BMJ</source>
          <date>
            <year>2005</year>
          </date>
          <fpage>313</fpage>
          <lpage>21</lpage>
          <issue>7512</issue>
          <volume>331</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Devereaux</surname>
              <given-names>PJ</given-names>
            </name>
            <name>
              <surname>Beattie</surname>
              <given-names>WS</given-names>
            </name>
            <name>
              <surname>Choi</surname>
              <given-names>PT</given-names>
            </name>
            <name>
              <surname>Badner</surname>
              <given-names>NH</given-names>
            </name>
            <name>
              <surname>Guyatt</surname>
              <given-names>GH</given-names>
            </name>
            <name>
              <surname>Villar</surname>
              <given-names>JC</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B17">
        <mixed-citation>17. Pogue JM, Yusuf S. Cumulating evidence from randomized trials: utilizing sequential monitoring boundaries for cumulative meta-analysis. Control Clin Trials. 1997;18(6):580-93.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Cumulating evidence from randomized trials: utilizing sequential monitoring boundaries for cumulative meta-analysis</article-title>
          <source>Control Clin Trials</source>
          <date>
            <year>1997</year>
          </date>
          <fpage>580</fpage>
          <lpage>93</lpage>
          <issue>6</issue>
          <volume>18</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Pogue</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Yusuf</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B18">
        <mixed-citation>18. Frey AW, Hodgson JM, Muller C, Bestehorn HP, Roskamm H. Ultrasound-guided strategy for provisional stenting with focal balloon combination catheter: results from the randomized Strategy for Intracoronary Ultrasound-guided PTCA and Stenting (SIPS) trial. Circulation. 2000;102(20):2497-502.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Ultrasound-guided strategy for provisional stenting with focal balloon combination catheter: results from the randomized Strategy for Intracoronary Ultrasound-guided PTCA and Stenting (SIPS) trial</article-title>
          <source>Circulation</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>2497</fpage>
          <lpage>502</lpage>
          <issue>20</issue>
          <volume>102</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Frey</surname>
              <given-names>AW</given-names>
            </name>
            <name>
              <surname>Hodgson</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Muller</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Bestehorn</surname>
              <given-names>HP</given-names>
            </name>
            <name>
              <surname>Roskamm</surname>
              <given-names>H</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B19">
        <mixed-citation>19. Jakabcin J, Spacek R, Bystron M, Kvasnak M, Jager J, Veselka J, et al. Long-term health outcome and mortality evaluation after invasive coronary treatment using drug eluting stents with or without the IVUS guidance. Randomized control trial. HOME DES IVUS. Catheter Cardiovasc Interv. 2010;75(4):578-83.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Long-term health outcome and mortality evaluation after invasive coronary treatment using drug eluting stents with or without the IVUS guidance: Randomized control trial. HOME DES IVUS</article-title>
          <source>Catheter Cardiovasc Interv</source>
          <date>
            <year>2010</year>
          </date>
          <fpage>578</fpage>
          <lpage>83</lpage>
          <issue>4</issue>
          <volume>75</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Jakabcin</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Spacek</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Bystron</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Kvasnak</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Jager</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Veselka</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B20">
        <mixed-citation>20. Schiele F, Meneveau N, Vuillemenot A, Zhang DD, Gupta S, Mercier M, et al. Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: a multicenter, randomized study comparing two strategies--with and without intravascular ultrasound guidance. RESIST Study Group. REStenosis after Ivus guided STenting. J Am Coll Cardiol. 1998;32(2):320-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: a multicenter, randomized study comparing two strategies--with and without intravascular ultrasound guidance. RESIST Study Group. REStenosis after Ivus guided STenting</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>320</fpage>
          <lpage>8</lpage>
          <issue>2</issue>
          <volume>32</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Schiele</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Meneveau</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Vuillemenot</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Zhang</surname>
              <given-names>DD</given-names>
            </name>
            <name>
              <surname>Gupta</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Mercier</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B21">
        <mixed-citation>21. Smith SC Jr, Feldman TE, Hirshfeld JW Jr, Jacobs AK, Kern MJ, King SB 3<sup>rd</sup>, et al. ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention--summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/SCAI Writing Committee to Update the 2001 Guidelines for Percutaneous Coronary Intervention). Circulation. 2006;113(1):156-75.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention--summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/SCAI Writing Committee to Update the 2001 Guidelines for Percutaneous Coronary Intervention)</article-title>
          <source>Circulation</source>
          <date>
            <year>2006</year>
          </date>
          <fpage>156</fpage>
          <lpage>75</lpage>
          <issue>1</issue>
          <volume>113</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Smith Jr</surname>
              <given-names>SC</given-names>
            </name>
            <name>
              <surname>Feldman</surname>
              <given-names>TE</given-names>
            </name>
            <name>
              <surname>Hirshfeld Jr</surname>
              <given-names>JW</given-names>
            </name>
            <name>
              <surname>Jacobs</surname>
              <given-names>AK</given-names>
            </name>
            <name>
              <surname>Kern</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>King 3rd</surname>
              <given-names>SB</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B22">
        <mixed-citation>22. Brunner-La Rocca HP, Kaiser C, Bernheim A, Zellweger MJ, Jeger R, Buser PT, et al. Cost-effectiveness of drug-eluting stents in patients at high or low risk of major cardiac events in the Basel Stent KostenEffektivitats Trial (BASKET): an 18-month analysis. Lancet. 2007;370(9598):1552-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Cost-effectiveness of drug-eluting stents in patients at high or low risk of major cardiac events in the Basel Stent KostenEffektivitats Trial (BASKET): an 18-month analysis</article-title>
          <source>Lancet</source>
          <date>
            <year>2007</year>
          </date>
          <fpage>1552</fpage>
          <lpage>9</lpage>
          <issue>9598</issue>
          <volume>370</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Brunner-La Rocca</surname>
              <given-names>HP</given-names>
            </name>
            <name>
              <surname>Kaiser</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Bernheim</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Zellweger</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Jeger</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Buser</surname>
              <given-names>PT</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B23">
        <mixed-citation>23. Wijns W, Kolh P, Danchin N, Di Mario C, Falk V, Folliguet T, et al. Guidelines on myocardial revascularization: The Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2010;31(20):2501-55.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Guidelines on myocardial revascularization: The Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS)</article-title>
          <source>Eur Heart J</source>
          <date>
            <year>2010</year>
          </date>
          <fpage>2501</fpage>
          <lpage>55</lpage>
          <issue>20</issue>
          <volume>31</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Wijns</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Kolh</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Danchin</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Di Mario</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Falk</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Folliguet</surname>
              <given-names>T</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B24">
        <mixed-citation>24. Daemen J, Simoons ML, Wijns W, Bagust A, Bos G, Bowen JM, et al. ESC Forum on Drug Eluting Stents European Heart House, Nice, 27-28 September 2007. Eur Heart J. 2009;30(2):152-61.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>ESC Forum on Drug Eluting Stents European Heart House, Nice, 27-28 September 2007</article-title>
          <source>Eur Heart J</source>
          <date>
            <year>2009</year>
          </date>
          <fpage>152</fpage>
          <lpage>61</lpage>
          <issue>2</issue>
          <volume>30</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Daemen</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Simoons</surname>
              <given-names>ML</given-names>
            </name>
            <name>
              <surname>Wijns</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Bagust</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Bos</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Bowen</surname>
              <given-names>JM</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B25">
        <mixed-citation>25. Kirtane AJ, Gupta A, Iyengar S, Moses JW, Leon MB, Applegate R, et al. Safety and efficacy of drug-eluting and bare metal stents: comprehensive meta-analysis of randomized trials and observational studies. Circulation. 2009;119(25):3198-206.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Safety and efficacy of drug-eluting and bare metal stents: comprehensive meta-analysis of randomized trials and observational studies</article-title>
          <source>Circulation</source>
          <date>
            <year>2009</year>
          </date>
          <fpage>3198</fpage>
          <lpage>206</lpage>
          <issue>25</issue>
          <volume>119</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Kirtane</surname>
              <given-names>AJ</given-names>
            </name>
            <name>
              <surname>Gupta</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Iyengar</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Moses</surname>
              <given-names>JW</given-names>
            </name>
            <name>
              <surname>Leon</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Applegate</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B26">
        <mixed-citation>26. Stettler C, Wandel S, Allemann S, Kastrati A, Morice MC, Schomig A, et al. Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis. Lancet. 2007;370(9591):937-48.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis</article-title>
          <source>Lancet</source>
          <date>
            <year>2007</year>
          </date>
          <fpage>937</fpage>
          <lpage>48</lpage>
          <issue>9591</issue>
          <volume>370</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Stettler</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Wandel</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Allemann</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Kastrati</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Morice</surname>
              <given-names>MC</given-names>
            </name>
            <name>
              <surname>Schomig</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B27">
        <mixed-citation>27. Kastrati A, Dibra A, Mehilli J, Mayer S, Pinieck S, Pache J, et al. Predictive factors of restenosis after coronary implantation of sirolimus- or paclitaxel-eluting stents. Circulation. 2006;113(19):2293-300.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Predictive factors of restenosis after coronary implantation of sirolimus- or paclitaxel-eluting stents</article-title>
          <source>Circulation</source>
          <date>
            <year>2006</year>
          </date>
          <fpage>2293</fpage>
          <lpage>300</lpage>
          <issue>19</issue>
          <volume>113</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Kastrati</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Dibra</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Mehilli</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Mayer</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Pinieck</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Pache</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B28">
        <mixed-citation>28. Quadros AS, Diemer F, Welter D, Modkovski T, Sarmento-Leite R, Gottschall CA. Validation of a risk score for target vessel revascularization after coronary stent implantation. J Invasive Cardiol. 2009;21(12):618-22.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Validation of a risk score for target vessel revascularization after coronary stent implantation</article-title>
          <source>J Invasive Cardiol</source>
          <date>
            <year>2009</year>
          </date>
          <fpage>618</fpage>
          <lpage>22</lpage>
          <issue>12</issue>
          <volume>21</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Quadros</surname>
              <given-names>AS</given-names>
            </name>
            <name>
              <surname>Diemer</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Welter</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Modkovski</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Sarmento-Leite</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Gottschall</surname>
              <given-names>CA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B29">
        <mixed-citation>29. Grines CL, Bonow RO, Casey DE Jr, Gardner TJ, Lockhart PB, Moliterno DJ, et al. Prevention of premature discontinuation of dual antiplatelet therapy in patients with coronary artery stents: a science advisory from the American Heart Association, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, American College of Surgeons, and American Dental Association, with representation from the American College of Physicians. Circulation. 2007;115(6):813-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Prevention of premature discontinuation of dual antiplatelet therapy in patients with coronary artery stents: a science advisory from the American Heart Association, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, American College of Surgeons, and American Dental Association, with representation from the American College of Physicians</article-title>
          <source>Circulation</source>
          <date>
            <year>2007</year>
          </date>
          <fpage>813</fpage>
          <lpage>8</lpage>
          <issue>6</issue>
          <volume>115</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Grines</surname>
              <given-names>CL</given-names>
            </name>
            <name>
              <surname>Bonow</surname>
              <given-names>RO</given-names>
            </name>
            <name>
              <surname>Casey Jr</surname>
              <given-names>DE</given-names>
            </name>
            <name>
              <surname>Gardner</surname>
              <given-names>TJ</given-names>
            </name>
            <name>
              <surname>Lockhart</surname>
              <given-names>PB</given-names>
            </name>
            <name>
              <surname>Moliterno</surname>
              <given-names>DJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B30">
        <mixed-citation>30. Pfisterer M, Brunner-La Rocca HP, Buser PT, Rickenbacher P, Hunziker P, Mueller C, et al. Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: an observational study of drug-eluting versus bare-metal stents. J Am Coll Cardiol. 2006;48(12):2584-91.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: an observational study of drug-eluting versus bare-metal stents</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2006</year>
          </date>
          <fpage>2584</fpage>
          <lpage>91</lpage>
          <issue>12</issue>
          <volume>48</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Pfisterer</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Brunner-La Rocca</surname>
              <given-names>HP</given-names>
            </name>
            <name>
              <surname>Buser</surname>
              <given-names>PT</given-names>
            </name>
            <name>
              <surname>Rickenbacher</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Hunziker</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Mueller</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B31">
        <mixed-citation>31. Spertus JA, Kettelkamp R, Vance C, Decker C, Jones PG, Rumsfeld JS, et al. Prevalence, predictors, and outcomes of premature discontinuation of thienopyridine therapy after drug-eluting stent placement: results from the PREMIER registry. Circulation. 2006;113(24):2803-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Prevalence, predictors, and outcomes of premature discontinuation of thienopyridine therapy after drug-eluting stent placement: results from the PREMIER registry</article-title>
          <source>Circulation</source>
          <date>
            <year>2006</year>
          </date>
          <fpage>2803</fpage>
          <lpage>9</lpage>
          <issue>24</issue>
          <volume>113</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Spertus</surname>
              <given-names>JA</given-names>
            </name>
            <name>
              <surname>Kettelkamp</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Vance</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Decker</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Jones</surname>
              <given-names>PG</given-names>
            </name>
            <name>
              <surname>Rumsfeld</surname>
              <given-names>JS</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B32">
        <mixed-citation>32. Zeymer U, Zahn R. Drug-eluting stents: effective and safe for every patient and every lesion? Eur Heart J. 2007;28(21):2559-60.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Drug-eluting stents: effective and safe for every patient and every lesion?</article-title>
          <source>Eur Heart J</source>
          <date>
            <year>2007</year>
          </date>
          <fpage>2559</fpage>
          <lpage>60</lpage>
          <issue>21</issue>
          <volume>28</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Zeymer</surname>
              <given-names>U</given-names>
            </name>
            <name>
              <surname>Zahn</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B33">
        <mixed-citation>33. Casella G, Klauss V, Ottami F, Siebert U, Sangiorgio P, Braccheti D. Impact of intravascular ultrasound guided stenting on long-term clinical outcome: A meta-analysis of available studies comparing intravascular ultrasound guided and angiographically guided stenting. Catheter Cardiovasc. Interv. 2003;59(3):314-21.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Impact of intravascular ultrasound guided stenting on long-term clinical outcome: A meta-analysis of available studies comparing intravascular ultrasound guided and angiographically guided stenting</article-title>
          <source>Catheter Cardiovasc Interv</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>314</fpage>
          <lpage>21</lpage>
          <issue>3</issue>
          <volume>59</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Casella</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Klauss</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Ottami</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Siebert</surname>
              <given-names>U</given-names>
            </name>
            <name>
              <surname>Sangiorgio</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Braccheti</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B34">
        <mixed-citation>34. Parise H, Maehara A, Stone GW, Leon MB, Mintz GS. Meta-analysis of randomized studies comparing intravascular ultrasound versus angiographic guidance of percutaneous coronary intervention in pre-drug-eluting stent era. Am J Cardiol. 2011;107(3):374-82.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Meta-analysis of randomized studies comparing intravascular ultrasound versus angiographic guidance of percutaneous coronary intervention in pre-drug-eluting stent era</article-title>
          <source>Am J Cardiol</source>
          <date>
            <year>2011</year>
          </date>
          <fpage>374</fpage>
          <lpage>82</lpage>
          <issue>3</issue>
          <volume>107</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Parise</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Maehara</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Stone</surname>
              <given-names>GW</given-names>
            </name>
            <name>
              <surname>Leon</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Mintz</surname>
              <given-names>GS</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B35">
        <mixed-citation>35. Schiele F, Meneveau N, Seronde MF, Caulfield F, Pisa B, Arveux P, et al. Medical costs of intravascular ultrasound optimization of stent deployment. Results of the multicenter randomized 'REStenosis after Intravascular ultrasound STenting' (RESIST) study. Int J Cardiovasc Intervent. 2000;3(4):207-13.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Medical costs of intravascular ultrasound optimization of stent deployment: Results of the multicenter randomized 'REStenosis after Intravascular ultrasound STenting' (RESIST) study</article-title>
          <source>Int J Cardiovasc Intervent</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>207</fpage>
          <lpage>13</lpage>
          <issue>4</issue>
          <volume>3</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Schiele</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Meneveau</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Seronde</surname>
              <given-names>MF</given-names>
            </name>
            <name>
              <surname>Caulfield</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Pisa</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Arveux</surname>
              <given-names>P</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Articles</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Intracoronary ultrasound-guided stenting improves outcomes: a meta-analysis of randomized trials</article-title>
      </title-group>
      <abstract xml:lang="en">
        <p>BACKGROUND: Intracoronary ultrasound (IVUS) has been used as an adjunctive method in order to optimize implantation of stents. However, the impact of this method in some outcomes is controversial. OBJECTIVE: To systematically review the impact of routine IVUS-guided coronary stent as compared to angiographic-guided, on clinical and angiographic outcomes. METHODS: A search of databases (MEDLINE, Cochrane CENTRAL, EMBASE) and references of published studies, from 1982 to 2010, was conducted. Randomized clinical trials (RCTs) that compared angiography plus IVUS-guided (IVUS) vs. angiography alone guided (ANGIO) coronary stent implantation were included. Minimum follow-up was 6 months and the outcomes assessed were major adverse cardiac events (MACE), target lesion revascularization (TLR) and angiographic restenosis. Two reviewers independently extracted the data. Summary risk ratio and 95% confidence intervals (CI) were calculated with random-effects models. The GRADE approach was used to determine the overall quality of evidence for each outcome. RESULTS: Out of 3,631 articles identified, 8 RCTs evaluating a total of 2,341 patients were included. There was a 27% reduction in angiographic restenosis (95%CI: 3%-46%) and a 38% reduction in TLR (95%CI: 17%-53%) in favor of IVUS vs. ANGIO. However, MACE were not reduced by IVUS (RR: 0.79; 95%CI: 0.61-1.03). The MACE data represent only 47% of the optimal information size required to reliably detect a plausible treatment effect. CONCLUSIONS: We observed that IVUS-guided coronary stenting provides significant reductions in TLR and angiographic restenosis compared to angiographically-guided stenting, but it does not reduce MACE.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>Ultrasonography, interventional</kwd>
        <kwd>meta-analysis</kwd>
        <kwd>randomized controlled trials</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p><undefined id="tx-body2"/>Intracoronary ultrasound-guided stenting improves outcomes: a meta-analysis of randomized trials</p>
      <p>
        <bold>Graciele Sbruzzi<sup>I</sup>; Alexandre Schaan de Quadros<sup>I</sup>; Rodrigo Antonini Ribeiro<sup>I</sup>; An&#237;bal Pereira Abelin<sup>I</sup>; Ot&#225;vio Berwanger<sup>IV</sup>; Rodrigo Della Me&#227; Plentz<sup>I, II</sup>; Beatriz DAgord Schann<sup>1, III</sup></bold>
      </p>
      <p><sup>I</sup>Instituto de Cardiologia do Rio Grande do Sul/Funda&#231;&#227;o Universit&#225;ria de Cardiologia, Porto Alegre, RS, Brazil</p>
      <p><sup>II</sup>Universidade Federal de Ci&#234;ncias da Sa&#250;de de Porto Alegre, Porto Alegre, RS, Brazil</p>
      <p><sup>III</sup>Hospital de Cl&#237;nicas de Porto Alegre/Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil</p>
      <p><sup>IV</sup>Instituto de Ensino e Pesquisa do HCor (Hospital do Cora&#231;&#227;o), S&#227;o Paulo, SP, Brazil</p>
      <p>Correspond&#234;ncia</p>
      <p>
        <bold>ABSTRACT</bold>
      </p>
      <p><bold>BACKGROUND:</bold> Intracoronary ultrasound (IVUS) has been used as an adjunctive method in order to optimize implantation of stents. However, the impact of this method in some outcomes is controversial.</p>
      <p><bold>OBJECTIVE:</bold> To systematically review the impact of routine IVUS-guided coronary stent as compared to angiographic-guided, on clinical and angiographic outcomes.</p>
      <p><bold>METHODS:</bold> A search of databases (MEDLINE, Cochrane CENTRAL, EMBASE) and references of published studies, from 1982 to 2010, was conducted. Randomized clinical trials (RCTs) that compared angiography plus IVUS-guided (IVUS) vs. angiography alone guided (ANGIO) coronary stent implantation were included. Minimum follow-up was 6 months and the outcomes assessed were major adverse cardiac events (MACE), target lesion revascularization (TLR) and angiographic restenosis. Two reviewers independently extracted the data. Summary risk ratio and 95% confidence intervals (CI) were calculated with random-effects models. The GRADE approach was used to determine the overall quality of evidence for each outcome.</p>
      <p><bold>RESULTS:</bold> Out of 3,631 articles identified, 8 RCTs evaluating a total of 2,341 patients were included. There was a 27% reduction in angiographic restenosis (95%CI: 3%-46%) and a 38% reduction in TLR (95%CI: 17%-53%) in favor of IVUS vs. ANGIO. However, MACE were not reduced by IVUS (RR: 0.79; 95%CI: 0.61-1.03). The MACE data represent only 47% of the optimal information size required to reliably detect a plausible treatment effect.</p>
      <p><bold>CONCLUSIONS:</bold> We observed that IVUS-guided coronary stenting provides significant reductions in TLR and angiographic restenosis compared to angiographically-guided stenting, but it does not reduce MACE.</p>
      <p><bold>Keywords:</bold> Ultrasonography, interventional / utilization; meta-analysis, randomized controlled trials.</p>
      <p>
        <bold>Introduction</bold>
      </p>
      <p>Coronary stent implantation represents the main percutaneous revascularization method in the current practice because it reduces restenosis and major adverse cardiac events (MACE)<sup>1</sup> when compared to balloon angioplasty. To assess the appropriateness of stent deployment during the procedure, quantitative coronary angiography and intravascular ultrasound (IVUS) can be used. As compared to the IVUS-guided procedure, the first method is cheaper, easier to perform and available in all centers. On the other hand, IVUS can provide important additional diagnostic information not assessed by angiography.</p>
      <p>After percutaneous coronary interventions, restenosis rates are strongly influenced by a small luminal diameter and a reduced cross sectional area of the vessel treated. The conceptual framework for the hypothesis that IVUS-guided percutaneous coronary intervention would result in better long-term angiographic and clinical outcomes when compared to the standard strategy (angiographic-guided only) is based on the observation that IVUS examination after stenting allows a safe and controlled aggressive post-dilatation, with large final diameters<sup>2,3</sup>. Colombo et al<sup>4</sup> were among the first to show that IVUS guided coronary stenting is safe, feasible and provides a better apposition of the prosthesis to the vascular wall than that obtained in the procedure without IVUS. In their seminal work, IVUS use to guide coronary stenting was associated with larger final luminal diameter and lower residual stenosis than not using IVUS during the procedure, with a significant lowering of thrombosis rates. Subsequent studies presented similar results<sup>5,6</sup> and also indicated beneficial effects of IVUS on MACE<sup>6,7</sup>. However, other authors did not show major clinical benefits of IVUS-guided stenting<sup>8,9</sup>.</p>
      <p>In the last decade, a number of observational and randomized studies have investigated the benefit of routine IVUS-guided stenting on long-term outcomes, but these studies have small sample sizes and conflicting results. In this study, we assessed the impact of routine IVUS-guided coronary stent implantation on long-term clinical and angiographic outcomes by means of a systematic review with meta-analysis of randomized clinical trials.</p>
      <p>
        <bold>Methods</bold>
      </p>
      <p>
        <bold>Eligibility criteria</bold>
      </p>
      <p>We included randomized clinical trials (RCTs) that compared angiography plus IVUS-guided (hereinafter referred to as IVUS) vs. angiography alone guided (hereafter referred to as ANGIO) coronary stent implantation in patients with symptomatic coronary lesion or silent ischemia, which evaluated any of the following outcomes: MACE, revascularization and/or angiographic restenosis. Trials with follow-up shorter than 6 months were excluded. If a trial had multiple publications (or substudies), the study was included only once. </p>
      <p>
        <bold>Search strategy and study selection</bold>
      </p>
      <p>We searched independently, in duplicate, from 1982 to March 2010, the following electronic databases: MEDLINE (accessed by PubMed), Cochrane Central Register of Controlled Trials (Cochrane CENTRAL) and EMBASE. In addition, we searched the references of published studies. The search was performed in March 2010 and comprised the following terms: "intravascular ultrasound", "intracoronary ultrasound", "IVUS", "coronary artery disease", associated with a high sensitivity strategy for the search of randomized clinical trials<sup>10</sup>. The searches were limited to English, Spanish and Portuguese language articles. The detailed strategies used are available on request. </p>
      <p>
        <bold>Data extraction</bold>
      </p>
      <p>Titles and abstracts of all articles identified by the search strategy were independently evaluated by two investigators (G.S. and A.P.A.), in duplicate. None of the abstracts provided sufficient information regarding the inclusion and exclusion criteria selected for full-text evaluation. In the second phase, the same reviewers independently evaluated these full-text articles and made their selection in accordance with the eligibility criteria. Disagreements between reviewers were solved by consensus, and, if the disagreement persisted, it was evaluated by a third reviewer (A.S.Q). To avoid potential double counting of patients included in more than one report of the same authors/working groups, patient recruitment periods and recruitment areas were evaluated, and authors were contacted for clarification. If the required data could not be found in the published report, the corresponding author was contacted to provide the missing data of interest. </p>
      <p>Two reviewers (G.S. and R.A.R.) independently conducted data extraction with regard to the methodological characteristics of the studies, interventions and outcomes using standardized forms; disagreements were solved by consensus or by a third reviewer (A.S.Q). The primary endpoint extracted was MACE, which was defined as death, myocardial infarction or revascularization procedure [as established by the authors, including new percutaneous coronary intervention (re-PCI), coronary artery bypass grafting surgery (CABG), target vessel revascularization (TVR) or target lesion revascularization (TLR)]. (<xref ref-type="table" rid="en_a112tab01-body2">Table 1</xref>). In addition, angiography restenosis (defined as &gt;50% diameter stenosis at 6 months), as well as all the aforementioned components of MACE, were also analyzed individually as secondary endpoints. </p>
      <p content-type="asset">
        <table-wrap id="en_a112tab01-body2">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gt01-en.jpg"/></table-wrap>
      </p>
      <p>
        <bold>Assessment of risk of bias</bold>
      </p>
      <p>Study quality assessment included adequate sequence generation, allocation concealment, blinding of assessors of outcomes, use of intention-to-treat analysis and description of losses and exclusions. Studies without a clear description of an adequate sequence generation were considered not to have fulfilled these criteria. A lack of description of how the allocation list was concealed (which could include terms like "central", "web-based" or "telephone randomization", or a clear statement that the allocation list was concealed) was judged to characterize absence of allocation concealment. Use of intention-to-treat analysis was considered as: confirmation on study assessment that the number of participants randomized and the number analyzed were identical, except for patients lost to follow-up or who withdrew consent for study participation. Studies without this characteristic were considered not to have fulfilled this criterion. Quality assessment was independently performed by two reviewers (G.S. and R.A.R.).</p>
      <p>
        <bold>Data analysis</bold>
      </p>
      <p>Summary risk ratios (RR) and 95% confidence intervals (CI) were calculated with random-effect models (Mantel-Haenszel) according to the number of events reported in the original studies or substudies intention-to-treat analysis. For the angiographic restenosis outcome, we used the case analysis available<sup>11</sup>. For this outcome, sensitivity analysis was carried out considering intention-to-treat analysis. Statistical heterogeneity of the treatment effects among studies was assessed using the Cochran's Q test and the inconsistency I<sup>2 </sup>test, in which values above 25% and 50% were considered to indicate moderate and high heterogeneity, respectively<sup>12</sup>. All analyses were conducted using Review Manager version 5.0 (Cochrane Collaboration)<sup>13</sup>.</p>
      <p>Sensitivity analyses were carried out considering the methodological characteristics of the studies (intention-to-treat analysis, adequate sequence generation, allocation concealment and blinding of assessors of outcomes). </p>
      <p>The authors had full access to the data and take full responsibility for its integrity. All authors gave their approval for submission of the final manuscript. </p>
      <p>
        <bold>Summary of findings</bold>
      </p>
      <p>We presented the overall quality of evidence using the GRADE approach as recommended by the Cochrane Handbook for Systematic Reviews of Interventions.<sup>11</sup> For each specific outcome, the quality of evidence was based on 5 factors: (1) limitations of the study design; (2) consistency of results; (3) directness; (4) precision and (5) potential for publication bias. The quality was reduced by one level for each of the factors not met. The GRADE approach resulted in 4 levels of quality of evidence: high, moderate, low and very low<sup>14</sup>. GRADE profiler software (version 3.2) was used<sup>15</sup>. </p>
      <p>
        <bold>Reliability and conclusiveness of data</bold>
      </p>
      <p>The optimal information sizing of evidence available on IVUS <italic>vs.</italic> ANGIO stenting was based on the composite outcome of MACE<sup>16,17</sup>. The sample size needed for a reliable and conclusive meta-analysis is at least as large as that for a single optimally powered RCT, so we calculated the sample size requirement for our meta-analysis. We used this optimal information size as a way of determining whether evidence in our meta-analysis was reliable and conclusive.</p>
      <p>
        <bold>Results</bold>
      </p>
      <p>
        <bold>Description of studies</bold>
      </p>
      <p>Out of 3,631 potentially relevant citations retrieved from electronic databases and searches of reference lists, 8 RCTs<sup>5-9,18-20</sup> met the inclusion criteria. <xref ref-type="fig" rid="en_a112fig01-body2">Figure 1</xref> shows the flow diagram of studies in this review. The studies included had a total of 2,397 patients (1,182 in the IVUS-guided stenting group). <xref ref-type="table" rid="en_a112tab01-body2">Table 1</xref> summarizes the characteristics of these studies. </p>
      <p content-type="asset">
        <fig id="en_a112fig01-body2">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gf01-en.jpg"/></fig>
      </p>
      <p>
        <bold>Risk of bias</bold>
      </p>
      <p>Out of the studies included, 37% presented adequate sequence generation, 62% reported allocation concealment, 62% had blinded assessment of outcomes, 87% described losses to follow-up and exclusions and 100% used the intention-to-treat principle for statistical analyses (<xref ref-type="table" rid="en_a112tab02-body2">Table 2</xref>).</p>
      <p content-type="asset">
        <table-wrap id="en_a112tab02-body2">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gt02-en.jpg"/></table-wrap>
      </p>
      <p>
        <bold>Effects of interventions</bold>
      </p>
      <p>
        <bold>Primary endpoint: Major adverse cardiac events</bold>
      </p>
      <p>Seven articles<sup>5-9,18,19</sup> (n = 2.186) evaluated MACE (<xref ref-type="fig" rid="en_a112fig02-body2">Figure 2</xref>). IVUS stenting was associated with a nonsignificant reduction of 21% in MACE compared to ANGIO stenting (RR: 0.79; 95% CI: 0.61-1.03; I<sup>2</sup>: 44%). Based on the GRADE approach, the quality of the evidence for this outcome was considered low, mainly because of imprecision and the inconsistency of the results (<xref ref-type="table" rid="en_a112tab03-body2">Table 3</xref>). </p>
      <p content-type="asset">
        <fig id="en_a112fig02-body2">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gf02-en.jpg"/></fig>
      </p>
      <p content-type="asset">
        <table-wrap id="en_a112tab03-body2">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gt03-en.jpg"/></table-wrap>
      </p>
      <p>Analyzing individual outcomes, we observed that IVUS stenting was associated with a non-significant increase of 35% in all-cause mortality<sup>5-9,18-20</sup> (RR: 1.35; 95% CI: 0.73-2.48; I<sup>2</sup>: 0%) and a non-significant reduction of 39% in myocardial infarction<sup>5-9,18,19</sup> (RR: 0.61; 95% CI: 0.29-1.26; I<sup>2</sup>: 37%) as compared to ANGIO stenting (<xref ref-type="fig" rid="en_a112fig02-body2">Figure 2</xref>). Based on the GRADE approach, the overall quality of evidence was moderate for all-cause mortality (on basis of the imprecision of the results) and low for myocardial infarction (based on imprecision and the inconsistency of the results) (<xref ref-type="table" rid="en_a112tab03-body2">Table 3</xref>).</p>
      <p>
        <bold>Secondary endpoints</bold>
      </p>
      <p>
        <bold>Angiographic restenosis</bold>
      </p>
      <p><xref ref-type="fig" rid="en_a112fig03-body2">Figure 3</xref> shows the comparison between IVUS vs. ANGIO stenting in relation to angiographic restenosis<sup>5-8,18,20</sup>. The IVUS-guided strategy determined a 27% reduction in angiographic restenosis (RR: 0.73; 95% CI: 0.54-0.97; I<sup>2</sup>: 51%). The number of patients needed to treat (NNT) in order to prevent one angiographic restenosis was 11. According to the GRADE approach, the quality of the evidence for this outcome was moderate based on the inconsistency of the results in this analysis (<xref ref-type="table" rid="en_a112tab03-body2">Table 3</xref>). </p>
      <p content-type="asset">
        <fig id="en_a112fig03-body2">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gf03-en.jpg"/></fig>
      </p>
      <p>
        <bold>Target lesion revascularization and target vessel revascularization</bold>
      </p>
      <p>Five RCTs<sup>5,6,9,18,19</sup> evaluated TLR and 2 articles<sup>5,7</sup> evaluated TVR (<xref ref-type="fig" rid="en_a112fig04-body2">Figure 4</xref>). There was a 38% reduction in TLR (RR: 0.62; 95% CI: 0.47-0.83; I<sup>2</sup>: 0%) in patients submitted to IVUS stenting vs. ANGIO stenting. The NNT to prevent one TLR was 20. Based on the GRADE approach, the evidence for TLR was of high quality (<xref ref-type="table" rid="en_a112tab03-body2">Table 3</xref>). Furthermore, there was a non-significant reduction of 42% in TVR (RR: 0.58; 95% CI: 0.30-1.12; I<sup>2</sup>: 0%) in favor of IVUS. According to GRADE, there was moderate quality evidence for this outcome on the basis of the imprecision of the results (<xref ref-type="table" rid="en_a112tab03-body2">Table 3</xref>).</p>
      <p content-type="asset">
        <fig id="en_a112fig04-body2">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gf04-en.jpg"/></fig>
      </p>
      <p>
        <bold>New percutaneous coronary intervention and coronary artery bypass grafting surgery</bold>
      </p>
      <p>Two articles<sup>7,8</sup> evaluated re-PCI and three<sup>7,9</sup> evaluated CABG surgery. IVUS stenting determined a non-significant reduction of 43% in re-PCI (RR: 0.57; 95% CI: 0.16-2.01; I<sup>2</sup>: 84%) and a non-significant reduction of 4% in CABG surgery (RR: 0.96; 95% CI: 0.52-1.77; I<sup>2</sup>: 0%) as compared to ANGIO stenting. Based on the GRADE approach, re-PCI and CABG surgery presented very low and moderate quality evidence, respectively (<xref ref-type="table" rid="en_a112tab03-body2">Table 3</xref>).</p>
      <p>
        <bold>Reliability and conclusiveness of data</bold>
      </p>
      <p>To determine the optimal information size, we assumed a 20% control event rate (the control event rate in our meta-analysis for MACE) and a 20% relative risk reduction with 90% power and a 0.01 two-sided &#945;. This calculation indicated that the optimal information size needed to reliably detect a plausible treatment effect for this outcome is at least 4,655 patients.</p>
      <p>
        <bold>Sensitivity analyses</bold>
      </p>
      <p>Sensitivity analyses were performed for the outcomes, MACE and angiographic restenosis. </p>
      <p>For MACE, no sensitivity analysis was performed considering the intention-to-treat analysis, because all studies included in this meta-analysis included this methodological characteristic. Regarding allocation concealment, the studies from Frey et al<sup>18</sup> and Oemrawsingh et al<sup>6</sup> were removed from the meta-analysis because they did not fulfill the criterion, though the result of the analysis remained unchanged (RR: 0.85, 95% CI: 0.64 -1.13; I<sup>2</sup>: 35%). We also observed the same pattern in relation to the proper description of the sequence of randomization, when, following the removal of studies<sup>5,6,8,19</sup> that failed to fulfill this characteristic, there was no change to the outcome of the analysis (RR: 0.83, 95% CI: 0.63-1.09 , I<sup>2</sup>: 36%). Furthermore, considering the blinding of assessors of outcomes, two articles<sup>7,19</sup> were removed from the meta-analysis and no difference was observed in the outcome (RR: 0.81, 95% CI: 0.59-1.11; I<sup>2</sup>: 52%). In addition, with the withdrawal of the study that used drug eluting stents (DES)<sup>19</sup> from the analysis, no change was observed in the results (RR: 0.76, 95% CI: 0.57-1.03; I<sup>2</sup>: 53%). </p>
      <p>The angiographic restenosis outcome was presented using the case analysis available. Therefore, sensitivity analysis was performed using intention-to-treat analysis through data imputation<sup>11</sup>. For this outcome, non-use of intention-to-treat analysis by the authors did not influence the meta-analysis result (RR: 0.80, 95% CI: 0.64-0.98; I<sup>2</sup>: 45%).</p>
      <p>
        <bold>Discussion</bold>
      </p>
      <p>In this article, we performed a systematic review and meta-analysis evaluating the impact of routine IVUS-guided coronary stent implantation on long-term outcomes. Our results demonstrated a significant reduction of 38% in TLR and 27% in angiographic restenosis with this strategy, but no statistically significant differences on total MACE, death or myocardial infarction. </p>
      <p>In the current interventional cardiology practice, IVUS penetration has been highly heterogeneous, according to the experience and preference of each center and operator. The last updated Guidelines for Percutaneous Coronary Intervention assign a class IIa recommendation, level of evidence B, for IVUS guided coronary stent implantation<sup>21</sup>. Our results may serve to strengthen this recommendation, since angiographic and clinical restenoses were significantly lowered with IVUS guidance. </p>
      <p>However, the cost of this technology should also be taken into account. Considering the NNT to prevent one TLR (20) and the usual additional cost to include IVUS in a PCI procedure (circa R$ 2,000), a total expenditure of R$ 40,000 would be needed to prevent one TLR. </p>
      <p>It is also important to consider if IVUS should be performed in all patients, or only in those at high risk of restenosis. Our analysis does not provide insights regarding the existence of subgroups with greater benefits, but it is reasonable to suggest that more complex patients could benefit more. The cost-benefit ratio of interventions aimed at reducing repeated revascularizations is also more favorable in those at high baseline restenosis risks<sup>22</sup>. </p>
      <p>Drug eluting stents are currently recommended for reduction of restenosis/re-occlusion, as long as no contraindication to extended dual antiplatelet therapy exists<sup>23-26</sup>. Our study did not address the question of whether routine IVUS-guided stenting is better than angiography alone when a DES is implanted<sup>19</sup>. Although some of the predictors of restenosis after DES or bare metal stent are similar<sup>27,28</sup>, extrapolation of the data from one population to the other may not be appropriate. However, our results should also be put into the perspective that not all patients in daily practice will be good candidates to receive a DES. Patients with contraindications or known poor adherence to long term dual antiplatelet therapy, planned noncardiac surgery and comorbidities associated with increased risk of bleeding represent some of these situations<sup>24,29-32</sup>. </p>
      <p>The sensitivity analyses performed did not change the global results of the meta-analysis. Frey et al<sup>18</sup> performed a randomized clinical with IVUS-guided provisional stenting vs. conventional treating, but a stent was not actually implanted in all patients. We decided to include this trial in this meta-analysis, and sensitivity analysis removing this study did not alter the results for MACE, mortality, myocardial infarction, angiographic restenosis and TLR. The study performed by Jakabcin et al<sup>19</sup> adopted routine DES implantation by protocol, and we have also decided to include data from this trial. In the sensitivity analysis performed where this study was removed, the results were not modified. </p>
      <p>Our study has several methodological strengths, which are: 1. Focused review questions, 2. A comprehensive and systematic literature search and 3. The collaboration of a multidisciplinary team of interventional cardiologists, healthcare researchers and methodologists, that used explicit and reproducible eligibility criteria and duplicate highly independent and reproducible eligibility decisions and data abstractions. We employed meta-analysis to quantitatively express the results obtained and evaluated the quality of evidence for each outcome analyzed. Another important strength of this report is that we calculated the sample size (optimal information size) requirement for our meta-analysis as a way of determining whether evidence in our meta-analysis was reliable and conclusive. </p>
      <p>Casella et al<sup>33</sup> have also conducted a meta-analysis in this field, which was published several years ago. This work included only 5 RCTs (n=1.883), while this review included 3 new RCTs, totaling 8 clinical trials (n=2.341). Considering only the analysis of RCTs of the first review<sup>33</sup>, IVUS-guided stenting did not reduce MACE (OR: 0.82, 95% CI: 0.64-1.04), death (OR: 1.27, 95% CI: 0.47-3.42) or myocardial infarction (OR: 0.96, 95% CI: 0.59-1.56), similar to the findings of this study. However, we did observe lower restenosis rates with IVUS-guided stenting in comparison with angiographically-guided stenting, which was not seen by Casella et al<sup>33</sup> (OR: 0.81, 95% CI: 0.62-1.06). It should be emphasized that our systematic review only included RCTs and had a larger number of studies as compared to that of Casella et al<sup>33</sup>, which may have contributed towards a better estimation of the data found by our group.</p>
      <p>Parise et al<sup>34</sup> have also performed a systematic review on this topic recently. In their paper, the results regarding restenosis were similar, but they have also found a benefit of IVUS in the reduction of MACE (OR 0.72, 95% CI 0.52 &#150; 0.99), which was not shown in our analysis. The major difference between the two meta-analyses is the omission of the RESIST trial MACE data in our calculations<sup>20</sup>, which, in its publication, did not present the definition of MACE. In fact, a secondary publication of that trial suggests that the numbers used in the Parise et al<sup>34</sup> paper included only revascularization and death, what falls out of our definition (and the one from all other trials) of MACE, which included myocardial infarction<sup>35</sup>. Moreover, our analysis based on the GRADE approach suggests low-quality evidence for this outcome, and our calculation of the optimal information size shows that the question about the benefit of IVUS regarding MACE is far from being adequately responded.</p>
      <p>Some limitations of our study should be pointed out. Firstly, most studies included in our systematic review may not represent the current PCI practice, since the stents used in the trials are not the ones employed today. PCI techniques have considerably changed, interventional cardiologists have more experience today than before, antiplatelet therapy is more aggressive and the complexity of the cases has increased<sup>25</sup>. Furthermore, the sample size was not ideal, since the total data available on MACE represent only 47% of the optimal information size required to reliably detect a plausible treatment effect. However, with more studies and with a larger number of patients, IVUS-guided stenting could significantly reduce MACE, since the p value for this analysis was 0.08. </p>
      <p>
        <bold>Conclusions</bold>
      </p>
      <p>This systematic review and meta-analysis demonstrates that IVUS-guided stenting reduces angiographic restenosis and TLR compared to angiographic-guided stenting, but do not reduce MACE. This data should provide further support for IVUS use, but the conduction of large scale and high-quality RCTs is needed to clarify the potential benefit of IVUS guidance regarding hard endpoints.</p>
      <p>
        <bold>Potential Conflict of Interest</bold>
      </p>
      <p>No potential conflict of interest relevant to this article was reported.</p>
      <p>
        <bold>Sources of Funding</bold>
      </p>
      <p>This study was partially funded by CNPq and CAPES.</p>
      <p>
        <bold>Study Association</bold>
      </p>
      <p>This study is not associated with any post-graduation program.</p>
      <p>
        <bold>References</bold>
      </p>
    </body>
  </sub-article>
  <sub-article article-type="translation" id="TRes" xml:lang="es">
    <front-stub>
      <article-categories/>
      <title-group>
        <article-title xml:lang="es">Implante de stents guiado por ultrasonido intracoronario mejora desenlaces: metan&#225;lisis de ensayos randomizados</article-title>
      </title-group>
      <abstract xml:lang="es">
        <p>FUNDAMENTO: El ultrasonido intracoronario (USIC) ha sido utilizado como m&#233;todo Complementario para optimizaci&#243;n del implante de stents. Entre tanto, el impacto de ese m&#233;todo en algunos desenlaces es controvertido. OBJETIVO: Revisar sistem&#225;ticamente el impacto de la adici&#243;n del USIC a la angiograf&#237;a para optimizaci&#243;n del implante de stents sobre los desenlaces cl&#237;nicos y angiogr&#225;ficos M&#201;TODOS: Fue conducida b&#250;squeda en las bases MEDLINE, Cochrane CENTRAL y EMBASE y referencias de estudios publicados, de 1982 a 2010. Fueron incluidos ensayos cl&#237;nicos randomizados (ECRs) que compararon USIC adicionado a angiograf&#237;a coronaria (USIC) vs. Angiograf&#237;a aislada (ANGIO) como gu&#237;a para implantaci&#243;n de stents. El seguimiento m&#237;nimo fue de 6 meses y los desenlaces analizados fueron eventos cardiovasculares mayores (ECVM), revascularizaci&#243;n del vaso blanco (RVB) y reestenosis angiogr&#225;fica. Dos revisores independientes extrajeron los datos. El riesgo relativo y el intervalo de confianza (IC) de 95% fueron calculados con efectos rand&#243;micos. El GRADE fue usado para determinar la calidad global de la evidencia para cada desenlace. RESULTADOS: De los 3.631 art&#237;culos identificados, 8 ECRs totalizando 2.341 pacientes fueron incluidos. Hubo una reducci&#243;n de 27% en la reestenosis angiogr&#225;fica (IC95%: 3%-46%) y una reducci&#243;n de 38% en la RVB (IC95%: 17%-53%) en favor del USIC vs. ANGIO. Entre tanto, ECVM no fueron reducidos por el USIC (RR: 0,79; IC95%: 0,61-1,03). Los datos de ECVM representan solamente 47% del tama&#241;o &#243;ptimo de la informaci&#243;n necesaria para detectar un efecto plausible de tratamiento. CONCLUSIONES: Fue observado que el implante de stents guiado por USIC promueve reducciones significativas en la RVB y reestenosis angiogr&#225;fica cuando es comparado a angiograf&#237;a aislada, sin embargo no reduce ECVM.</p>
      </abstract>
      <kwd-group xml:lang="es">
        <kwd>Ultrasonograf&#237;a de intervenci&#243;n</kwd>
        <kwd>enfermedad de las coronarias</kwd>
        <kwd>revisi&#243;n</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>ART&#205;CULO ORIGINAL</bold>
      </p>
      <p>
        <fn id="enda-body3">
          <label>
            <bold>Implante de stents guiado por ultrasonido intracoronario mejora desenlaces: metan&#225;lisis de ensayos randomizados</bold>
          </label>
          <p>
            <bold>Graciele Sbruzzi<sup>I</sup>; Alexandre Schaan de Quadros<sup>I</sup>; Rodrigo Antonini Ribeiro<sup>I</sup>; An&#237;bal Pereira Abelin<sup>I</sup>; Ot&#225;vio Berwanger<sup>IV</sup>; Rodrigo Della M&#233;a Plentz<sup>I,II</sup>; Beatriz D'Agord Schaan<sup>I,</sup><sup>III</sup></bold>
          </p>
        </fn>
      </p>
      <p><sup>I</sup>Instituto de Cardiologia do Rio Grande do Sul/Funda&#231;&#227;o Universit&#225;ria de Cardiologia</p>
      <p><sup>II</sup>Universidade Federal de Ci&#234;ncias da Sa&#250;de de Porto Alegre</p>
      <p><sup>III</sup>Hospital de Cl&#237;nicas de Porto Alegre/Universidade Federal do Rio Grande do Sul, Porto Alegre, RS</p>
      <p><sup>IV</sup>Instituto de Ensino e Pesquisa do HCor (Hospital do Cora&#231;&#227;o), S&#227;o Paulo, SP, Brasil </p>
      <p>Correspondencia</p>
      <p>
        <bold>RESUMEN</bold>
      </p>
      <p><bold>FUNDAMENTO:</bold> El ultrasonido intracoronario (USIC) ha sido utilizado como m&#233;todo Complementario para optimizaci&#243;n del implante de <italic>stents</italic>. Entre tanto, el impacto de ese m&#233;todo en algunos desenlaces es controvertido.</p>
      <p><bold>OBJETIVO:</bold> Revisar sistem&#225;ticamente el impacto de la adici&#243;n del USIC a la angiograf&#237;a para optimizaci&#243;n del implante de <italic>stents</italic> sobre los desenlaces cl&#237;nicos y angiogr&#225;ficos</p>
      <p><bold>M&#201;TODOS:</bold> Fue conducida b&#250;squeda en las bases MEDLINE, Cochrane CENTRAL y EMBASE y referencias de estudios publicados, de 1982 a 2010. Fueron incluidos ensayos cl&#237;nicos randomizados (ECRs) que compararon USIC adicionado a angiograf&#237;a coronaria (USIC) vs. Angiograf&#237;a aislada (ANGIO) como gu&#237;a para implantaci&#243;n de <italic>stents</italic>. El seguimiento m&#237;nimo fue de 6 meses y los desenlaces analizados fueron eventos cardiovasculares mayores (ECVM), revascularizaci&#243;n del vaso blanco (RVB) y reestenosis angiogr&#225;fica. Dos revisores independientes extrajeron los datos. El riesgo relativo y el intervalo de confianza (IC) de 95% fueron calculados con efectos rand&#243;micos. El GRADE fue usado para determinar la calidad global de la evidencia para cada desenlace.</p>
      <p><bold>RESULTADOS:</bold> De los 3.631 art&#237;culos identificados, 8 ECRs totalizando 2.341 pacientes fueron incluidos. Hubo una reducci&#243;n de 27% en la reestenosis angiogr&#225;fica (IC95%: 3%-46%) y una reducci&#243;n de 38% en la RVB (IC95%: 17%-53%) en favor del USIC vs. ANGIO. Entre tanto, ECVM no fueron reducidos por el USIC (RR: 0,79; IC95%: 0,61-1,03). Los datos de ECVM representan solamente 47% del tama&#241;o &#243;ptimo de la informaci&#243;n necesaria para detectar un efecto plausible de tratamiento.</p>
      <p><bold>CONCLUSIONES:</bold> Fue observado que el implante de <italic>stents</italic> guiado por USIC promueve reducciones significativas en la RVB y reestenosis angiogr&#225;fica cuando es comparado a angiograf&#237;a aislada, sin embargo no reduce ECVM.</p>
      <p><bold>Palabras clave:</bold> Ultrasonograf&#237;a de intervenci&#243;n, enfermedad de las coronarias, revisi&#243;n.</p>
      <p>
        <bold>Introducci&#243;n</bold>
      </p>
      <p>El implante de <italic>stent</italic> coronario representa el principal m&#233;todo de revascularizaci&#243;n percut&#225;nea en la pr&#225;ctica actual, pues reduce reestenosis y eventos cardiovasculares mayores (ECVM)<sup>1</sup> cuando es comparado a la angioplastia con bal&#243;n. Para evaluar la adecuaci&#243;n de la implantaci&#243;n del <italic>stent</italic> durante el procedimiento, se puede usar la angiograf&#237;a coronaria cuantitativa y el ultrasonido intracoronario (USIC). En comparaci&#243;n con el procedimiento guiado por ultrasonido intracoronario, el primer m&#233;todo es m&#225;s barato, m&#225;s f&#225;cil de ejecutar y disponible en todos los centros. Por otro lado, el USIC puede proveer informaciones diagn&#243;sticas adicionales importantes no evaluadas por la angiograf&#237;a.</p>
      <p>Despu&#233;s de la intervenci&#243;n coronaria percut&#225;nea, las tasas de reestenosis son fuertemente influenciadas por un peque&#241;o di&#225;metro luminal y el &#225;rea seccional transversal reducida de la arteria tratada. La estructura conceptual para la hip&#243;tesis de que la intervenci&#243;n coronaria percut&#225;nea guiada por el USIC resultar&#237;a en mejores resultados angiogr&#225;ficos y cl&#237;nicos de largo plazo, cuando son comparados a la estrategia est&#225;ndar (procedimientos guiados apenas por angiograf&#237;a), se basa en la observaci&#243;n de que el examen de USIC despu&#233;s del implante de <italic>stent</italic> permite una post dilataci&#243;n agresiva segura y controlada con grandes di&#225;metros finales<sup>2,3</sup>. Colombo et al<sup>4</sup> estuvieron entre los primeros en mostrar que el implante de <italic>stent</italic> coronario guiado por USIC es seguro, viable y proporciona una mejor yuxtaposici&#243;n de la pr&#243;tesis a la pared vascular que el resultado obtenido en el procedimiento sin USIC. En su trabajo seminal, el USIC utilizado para guiar la implantaci&#243;n del <italic>stent</italic> coronario estuvo asociado con mayor di&#225;metro luminal final y menor estenosis residual en comparaci&#243;n con la no utilizaci&#243;n del USIC durante el procedimiento, con una reducci&#243;n significativa de las tasas de trombosis. Estudios subsecuentes presentaron resultados semejantes<sup>5,6</sup> y tambi&#233;n indicaron los efectos ben&#233;ficos del USIC en los casos de ECVM<sup>6,7</sup>. Mientras tanto, otros autores no mostraron grandes beneficios cl&#237;nicos del USIC como gu&#237;a en la implantaci&#243;n de <italic>stents</italic><sup>8,9</sup>.</p>
      <p>En la &#250;ltima d&#233;cada, una serie de estudios observacionales y randomizados han investigado el beneficio del <italic>stent</italic> guiado por USIC en resultados de largo plazo, pero esos estudios poseen peque&#241;os tama&#241;os de muestra y resultados conflictivos. En este estudio evaluamos el impacto de la implantaci&#243;n de rutina de <italic>stent</italic> coronario guiado por USIC en los resultados cl&#237;nicos y angiogr&#225;ficos de largo plazo por medio de una revisi&#243;n sistem&#225;tica con metan&#225;lisis de ensayos cl&#237;nicos randomizados.</p>
      <p>
        <bold>M&#233;todos</bold>
      </p>
      <p>
        <bold>Criterios de elegibilidad</bold>
      </p>
      <p>Fueron incluidos Ensayos Cl&#237;nicos Randomizados (ECR) que compararon el implante de <italic>stent</italic> coronario guiado por angiograf&#237;a m&#225;s USIC (en adelante designado como USIC) <italic>versus</italic> implante de <italic>stent</italic> coronario guiado apenas por angiograf&#237;a (en adelante designado como ANGIO) en pacientes con lesi&#243;n coronaria sintom&#225;tica o isquemia silenciosa, habiendo evaluado los siguientes resultados: ECVM, revascularizaci&#243;n y/o reestenosis angiogr&#225;fica. Ensayos con control inferior a seis meses fueron excluidos. En casos de ensayos con varias publicaciones (o subestudios), el estudio fue incluido apenas una vez.</p>
      <p>
        <bold>Estrategia de b&#250;squeda y selecci&#243;n de los estudios</bold>
      </p>
      <p>Procuramos de forma independiente y duplicada, entre el per&#237;odo de 1982 y marzo de 2010, en las siguientes bases de datos electr&#243;nicas: MEDLINE (a trav&#233;s del PubMed), Cochrane Central Register of Controlled Trials (Cochrane CENTRAL) y EMBASE. Adem&#225;s de eso, buscamos las referencias de estudios publicados. La b&#250;squeda fue realizada en marzo de 2010 y fue compuesta por los siguientes t&#233;rminos: "ultrasonido intravascular", "ultrasonido intracoronario", "USIC", "enfermedad arterial coronaria", asociada a una estrategia de alta sensibilidad para la b&#250;squeda de ensayos cl&#237;nicos randomizados<sup>10</sup>. Las b&#250;squedas fueron limitadas a art&#237;culos en ingl&#233;s, espa&#241;ol y portugu&#233;s. Las estrategias detalladas utilizadas pueden ser ofrecidas mediante solicitud.</p>
      <p>
        <bold>Extracci&#243;n de datos</bold>
      </p>
      <p>Los t&#237;tulos y res&#250;menes de todos los art&#237;culos identificados por la estrategia de b&#250;squeda fueron evaluados independientemente por dos investigadores (G.S. y A.P.A.), de forma duplicada. Todos los res&#250;menes que no proveyeron informaciones suficientes respecto a los criterios de inclusi&#243;n y exclusi&#243;n fueron seleccionados para evaluaci&#243;n del art&#237;culo completo. En la segunda fase, los mismos revisores, de manera independiente, evaluaron los art&#237;culos &#237;ntegramente e hicieron su selecci&#243;n de acuerdo con los criterios de elegibilidad. Los desacuerdos entre los revisores fueron resueltos por consenso, y, en casos de persistencia del desacuerdo, la evaluaci&#243;n era hecha por un tercer revisor (A.S.Q.). Para evitar posibles dobles recuentos de pacientes incluidos en m&#225;s de un informe de los mismos autores/grupos de trabajo, fueron evaluados los per&#237;odos de reclutamiento de pacientes y &#225;reas de reclutamiento, y los autores fueron contactados para aclaraciones. En caso de que no fuesen encontrados en el informe publicado los datos necesarios, el respectivo autor era contactado para proveer los datos faltantes.</p>
      <p>Dos revisores (G.S. y R.A.R.) condujeron, de forma independiente, la extracci&#243;n de los datos en lo que se refiere a las caracter&#237;sticas metodol&#243;gicas de los estudios, intervenciones y resultados por medio de formularios estandarizados; los desacuerdos fueron resueltos por consenso o por un tercer revisor (A.S.Q.). El desenlace primario colectado fue ECVM, que fue definido como muerte, infarto de miocardio o procedimiento de revascularizaci&#243;n [seg&#250;n lo establecido por los autores, incluyendo Intervenci&#243;n Coronaria Percut&#225;nea (nueva ICP), Cirug&#237;a de Revascularizaci&#243;n Mioc&#225;rdica quir&#250;rgica (CRM), Revascularizaci&#243;n del Vaso Blanco (RVB) o revascularizaci&#243;n de la lesi&#243;n blanco (RLB)] (<xref ref-type="table" rid="es_a07tab01m-body3">Tabla 1</xref>). Adem&#225;s de eso, la reestenosis angiogr&#225;fica (definida como estenosis de di&#225;metro &gt;50% en seis meses), as&#237; como todos los componentes de ECVM encima descriptos tambi&#233;n fueron analizados individualmente como desenlaces secundarios.</p>
      <p content-type="asset">
        <table-wrap id="es_a07tab01m-body3">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gt01-es.jpg"/></table-wrap>
      </p>
      <p>
        <bold>Evaluaci&#243;n del riesgo de sesgo</bold>
      </p>
      <p>La evaluaci&#243;n de la calidad de los estudios incluy&#243; adecuada generaci&#243;n de la secuencia de randomizaci&#243;n, secreto de la ubicaci&#243;n, cegamiento de los evaluadores de los resultados, el uso del an&#225;lisis por intenci&#243;n de tratar y descripci&#243;n de las p&#233;rdidas y exclusiones. Estudios sin una descripci&#243;n clara de una generaci&#243;n de secuencia adecuada fueron considerados como no habiendo atendido esos criterios. Se consider&#243; que la falta de descripci&#243;n de c&#243;mo fue ocultada la lista de ubicaci&#243;n (lo que puede incluir t&#233;rminos como "central", "basado en la web" o "randomizaci&#243;n por tel&#233;fono", o una afirmaci&#243;n clara de que la lista de ubicaci&#243;n fue ocultada) caracterizaba ausencia de ocultaci&#243;n de ubicaci&#243;n. El uso del an&#225;lisis intenci&#243;n de tratar fue considerado como: confirmaci&#243;n sobre la evaluaci&#243;n de estudio de que el n&#250;mero de participantes randomizados y analizados eran id&#233;nticos, excepto para los pacientes que perdieron el seguimiento o que retiraron su consentimiento para participaci&#243;n en el estudio. Se consider&#243; que estudios sin esa caracter&#237;stica no hab&#237;an atendido ese criterio. La evaluaci&#243;n de la calidad fue realizada de forma independiente por dos revisores (G.S. y R.A.R.).</p>
      <p>
        <bold>An&#225;lisis de datos</bold>
      </p>
      <p>Los &#237;ndices de riesgo relativo (RR) e intervalos de confianza de 95% (IC) fueron calculados con modelos de efecto aleatorio (Mantel-Haenszel) de acuerdo con el n&#250;mero de eventos relatados en el an&#225;lisis de intenci&#243;n de tratar de los estudios originales o subestudios. Para el resultado de reestenosis angiogr&#225;fica, fue utilizado el an&#225;lisis de caso disponible<sup>11</sup>. Para ese resultado, el an&#225;lisis de sensibilidad fue realizado considerando el an&#225;lisis de intenci&#243;n de tratar. La heterogeneidad estad&#237;stica de los efectos de tratamiento entre los estudios fue evaluada por el test Q de Cochran y test de inconsistencia I<sup>2</sup>, en que, en que se consider&#243; que valores encima de 25% y 50% indicaban heterogeneidad moderada y alta, respectivamente<sup>12</sup>. Todos los an&#225;lisis fueron realizados utilizando el Review Manager versi&#243;n 5.0 (Colaboraci&#243;n Cochrane)<sup>13</sup>.</p>
      <p>Los an&#225;lisis de sensibilidad fueron realizados considerando las caracter&#237;sticas metodol&#243;gicas de los estudios (an&#225;lisis de intenci&#243;n de tratar, generaci&#243;n adecuada de secuencia, secreto de la ubicaci&#243;n y cegamiento de los evaluadores de desenlaces).</p>
      <p>Los autores ten&#237;an pleno acceso a los datos y asumieron total responsabilidad por su integridad. Todos los autores dieron su aprobaci&#243;n para la presentaci&#243;n del manuscrito final.</p>
      <p>
        <bold>Resumen de los resultados</bold>
      </p>
      <p>Presentamos la calidad general de las evidencias usando el abordaje GRADE seg&#250;n es recomendado por el <italic>Cochrane Handbook for Systematic Reviews of Interventions</italic>. Para cada resultado espec&#237;fico, la calidad de las evidencias se bas&#243; en cinco factores: (1) limitaciones del dise&#241;o del estudio; (2) consistencia de los resultados; (3) objetividad; (4) precisi&#243;n y (5) potencial de sesgo de publicaci&#243;n. La calidad fue reducida en un nivel para cada uno de los factores no atendidos. El abordaje GRADE result&#243; en cuatro niveles de calidad de la evidencia: alta, moderada, baja y muy baja<sup>14</sup>. El software GRADE Profiler (versi&#243;n 3.2) fue utilizado<sup>15</sup>.</p>
      <p>
        <bold>Confiabilidad y conclusividad de los datos</bold>
      </p>
      <p>El dimensionamiento ideal de las informaciones de evidencias disponibles sobre el implante de <italic>stent</italic> por USIC <italic>versus</italic> ANGIO se bas&#243; en el resultado compuesto de ECVM<sup>16,17</sup>. El tama&#241;o de muestra necesario para un metan&#225;lisis confiable y conclusivo ser&#237;a el tama&#241;o necesario para un ECR &#250;nico y ideal, entonces calculamos el tama&#241;o de muestra ideal para nuestro metan&#225;lisis. Utilizamos esa dimensi&#243;n ideal de informaciones como una manera de determinar si las evidencias en nuestro metan&#225;lisis eran confiables y conclusivas.</p>
      <p>
        <bold>Resultados</bold>
      </p>
      <p>
        <bold>Descripci&#243;n de los estudios</bold>
      </p>
      <p>De 3.631 citaciones potencialmente relevantes recuperadas de bancos de datos electr&#243;nicos y pesquisas de listas de referencia, ocho RCT<sup>5-9,18-20</sup> llenaron los criterios de inclusi&#243;n. La <xref ref-type="fig" rid="es_a07fig01m-body3">figura 1</xref> muestra el flujograma de estudios en esta revisi&#243;n. Los estudios incluidos ten&#237;an un total de 2.397 pacientes (1.182 en el grupo de implante de <italic>stent</italic> guiado por USIC). La <xref ref-type="table" rid="es_a07tab01m-body3">tabla 1</xref> resume las caracter&#237;sticas de esos estudios.</p>
      <p content-type="asset">
        <fig id="es_a07fig01m-body3">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gf01-es.jpg"/></fig>
      </p>
      <p>
        <bold>Riesgo de sesgo</bold>
      </p>
      <p>De los estudios incluidos, 37% presentaron generaci&#243;n de secuencia adecuada, 62% relataron ocultaci&#243;n de ubicaci&#243;n, 62% hab&#237;an cegado los evaluadores de desenlaces, 87% describieron p&#233;rdidas de seguimiento y exclusiones, y 100% utilizaron el principio del an&#225;lisis de intenci&#243;n de tratar para an&#225;lisis estad&#237;sticos (<xref ref-type="table" rid="es_a07tab02m-body3">Tabla 2</xref>).</p>
      <p content-type="asset">
        <table-wrap id="es_a07tab02m-body3">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gt02-es.jpg"/></table-wrap>
      </p>
      <p>
        <bold>Efectos de las intervenciones</bold>
      </p>
      <p>
        <bold>Desenlace primario: eventos cardiovasculares mayores</bold>
      </p>
      <p>Siete art&#237;culos<sup>5-9,18,19</sup> (n = 2,186) evaluaron ECVM (<xref ref-type="fig" rid="es_a07fig02m-body3">Figura 2</xref>). El implante de <italic>stent</italic> guiado por USIC estuvo asociado a una reducci&#243;n no significativa de 21% de ECVM en comparaci&#243;n con el implante de <italic>stent</italic> guiado por la ANGIO (RR: 0,79; IC 95%: 0,61-1,03; I<sup>2</sup>: 44%). Con base en el abordaje GRADE, la calidad de las evidencias para este resultado fue considerada baja, principalmente por causa de la imprecisi&#243;n e inconsistencia de los resultados (<xref ref-type="table" rid="es_a07tab03m-body3">Tabla 3</xref>).</p>
      <p content-type="asset">
        <fig id="es_a07fig02m-body3">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gf02-es.jpg"/></fig>
      </p>
      <p content-type="asset">
        <table-wrap id="es_a07tab03m-body3">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gt03-es.jpg"/></table-wrap>
      </p>
      <p>Analizando los resultados de forma individual, observamos que el implante de <italic>stent</italic> guiado por USIC estaba asociado a un aumento no significativo de 35% en la mortalidad por todas las causas<sup>5-9,18-20</sup> (RR: 1,35; IC 95%: 0,73-2,48; I<sup>2</sup>: 0%) y una reducci&#243;n significativa de 39% en el infarto de miocardio<sup>5-9,18,19</sup> (RR: 0,61; IC 95%: 0,29-1,26; I<sup>2</sup>: 37%) en comparaci&#243;n con el implante de <italic>stent</italic> guiado por ANGIO (<xref ref-type="fig" rid="es_a07fig02m-body3">Fig. 2</xref>). Con base en el abordaje GRADE, la calidad general de las evidencias se present&#243; moderada para la mortalidad por todas las causas (con base en la imprecisi&#243;n de los resultados) y baja para el infarto del miocardio (con base en la imprecisi&#243;n y en la inconsistencia de los resultados) (<xref ref-type="table" rid="es_a07tab03m-body3">Tabla 3</xref>).</p>
      <p>
        <bold>Desenlaces secundarios</bold>
      </p>
      <p>
        <bold>Reestenosis angiogr&#225;fica</bold>
      </p>
      <p>La <xref ref-type="fig" rid="es_a07fig03m-body3">figura 3</xref> muestra una comparaci&#243;n entre el implante de <italic>stent</italic> guiado por USIC <italic>versus </italic>ANGIO en relaci&#243;n a la reestenosis angiogr&#225;fica<sup>5-8,18,20</sup>. La estrategia guiada por USIC determin&#243; una reducci&#243;n de 27% en la reestenosis angiogr&#225;fica (RR: 0,73; IC 95%: 0,54-0,97; I<sup>2</sup>: 51%). El n&#250;mero de pacientes necesarios para tratar (NNT) para evitar una reestenosis angiogr&#225;fica fue 11. De acuerdo con el abordaje GRADE, la calidad de las evidencias para ese resultado se present&#243; moderada con base en la inconsistencia de los resultados obtenidos en ese an&#225;lisis (<xref ref-type="table" rid="es_a07tab03m-body3">Tabla 3</xref>).</p>
      <p content-type="asset">
        <fig id="es_a07fig03m-body3">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gf03-es.jpg"/></fig>
      </p>
      <p>
        <bold>Revascularizaci&#243;n de lesi&#243;n blanco y revascularizaci&#243;n de vaso blanco</bold>
      </p>
      <p>Cinco ECR<sup>5,6,9,18,19</sup> evaluaron RLB y dos art&#237;culos<sup>5,7</sup> evaluaron RVB (<xref ref-type="fig" rid="es_a07fig04m-body3">Figura 4</xref>). Hubo una reducci&#243;n de 38% en los casos de RLB (RR: 0,62; IC 95%: 0,47-0,83; I<sup>2</sup>: 0%) en pacientes sometidos a implante de <italic>stent</italic> guiado por USIC <italic>versus</italic> ANGIO. El NNT para prevenir una RLB fue 20. Con base en el abordaje GRADE, las evidencias para RLB fue de alta calidad (<xref ref-type="table" rid="es_a07tab03m-body3">Tabla 3</xref>). Adem&#225;s de eso, hubo una reducci&#243;n no significativa de 42% en los casos de RVB (RR: 0,58; IC 95%: 0,30-1,12; I2: 0%) en favor del USIC. De acuerdo con el abordaje GRADE, hab&#237;a evidencias de calidad moderada para ese resultado con base en la imprecisi&#243;n de los resultados (<xref ref-type="table" rid="es_a07tab03m-body3">Tabla 3</xref>).</p>
      <p content-type="asset">
        <fig id="es_a07fig04m-body3">
          <graphic xlink:href="1678-4170-abc-98-01-0035-00118-gf04-es.jpg"/></fig>
      </p>
      <p>
        <bold>Nuevos procedimientos de intervenci&#243;n coronaria percut&#225;nea y cirug&#237;a de revascularizaci&#243;n mioc&#225;rdica</bold>
      </p>
      <p>Dos art&#237;culos<sup>7,8</sup> evaluaron nueva ICP y tres evaluaron la cirug&#237;a de revascularizaci&#243;n mioc&#225;rdica<sup>7,9</sup>. El implante de <italic>stent</italic> guiado por USIC determin&#243; una reducci&#243;n no significativa de 43% en los casos de nueva PCI (RR: 0,57; IC 95%: 0,16-2,01; I2: 84%) y una reducci&#243;n no significativa de 4% en los casos de cirug&#237;a de revascularizaci&#243;n mioc&#225;rdica (RR: 0,96; IC 95%: 0,52-1,77; I2: 0%) en comparaci&#243;n con el implante de <italic>stent</italic> guiado por ANGIO. Con base en el abordaje GRADEh, re-PCI y cirug&#237;a de revascularizaci&#243;n mioc&#225;rdica presentaron evidencias de calidad muy baja y moderada, respectivamente (<xref ref-type="table" rid="es_a07tab03m-body3">Tabla 3</xref>).</p>
      <p>
        <bold>Confiabilidad y conclusividad de los datos</bold>
      </p>
      <p>Para determinar la dimensi&#243;n ideal de las informaciones, asumimos una tasa de eventos en los controles de 20% (la tasa de evento en los controles en nuestro metan&#225;lisis para ECVM) y una reducci&#243;n del riesgo relativo en 20%, con poder de 90% y &#945; bilateral de 0,01. Ese c&#225;lculo indica que la dimensi&#243;n ideal de informaciones necesarias para detectar con seguridad un efecto de tratamiento plausible para ese resultado es de por lo menos 4.655 pacientes.</p>
      <p>
        <bold>An&#225;lisis de sensibilidad</bold>
      </p>
      <p>Los an&#225;lisis de sensibilidad fueron realizados para los desenlaces, ECVM y reestenosis angiogr&#225;fica.</p>
      <p>Para ECVM, no fue realizado an&#225;lisis de sensibilidad consider&#225;ndose el an&#225;lisis de intenci&#243;n de tratar, debido al hecho de que todos los estudios incluidos en ese metan&#225;lisis incluyeron esa caracter&#237;stica metodol&#243;gica. Sobre secreto de la ubicaci&#243;n, los estudios de Frey et al<sup>18</sup> y Oemrawsingh et al<sup>6</sup> fueron removidos del metan&#225;lisis pues no respond&#237;an al criterio, aunque el resultado del an&#225;lisis permaneciese inalterado (RR: 0,85, IC 95%:: 0,64 -1,13; I<sup>2</sup>: 35%). Tambi&#233;n observamos el mismo est&#225;ndar en relaci&#243;n a la descripci&#243;n adecuada de la secuencia de randomizaci&#243;n, cuando, despu&#233;s de la retirada de los estudios<sup>5,6,8,19</sup> que no atend&#237;an a esa caracter&#237;stica, no hab&#237;a alteraci&#243;n en el resultado del an&#225;lisis (RR: 0,83, IC 95%: 0,63-1,09, I2: 36%). Adem&#225;s de eso, considerando el cegamiento de los evaluadores de los resultados, dos art&#237;culos<sup>7,19</sup> fueron retirados del metan&#225;lisis y no hubo diferencia en el resultado (RR: 0,81, IC 95%: 0,59-1,11; I<sup>2</sup>: 52%). Con la retirada del estudio que utiliz&#243; <italic>stents</italic> farmacol&#243;gicos<sup>19</sup> del an&#225;lisis, ning&#250;n cambio fue observado en los resultados (RR: 0,76, IC 95%: 0,57-1,03; I<sup>2</sup>: 53%).</p>
      <p>El resultado de reestenosis angiogr&#225;fica fue presentado utilizando el an&#225;lisis de caso disponible. Por lo tanto, fue realizado an&#225;lisis de sensibilidad utilizando el an&#225;lisis de intenci&#243;n de tratar por medio de la imputaci&#243;n de datos<sup>11</sup>. Para ese resultado, la no utilizaci&#243;n del an&#225;lisis de intenci&#243;n de tratar por parte de los autores no influenci&#243; el resultado del metan&#225;lisis (RR: 0,80, IC 95%: 0,64-0,98; I<sup>2</sup>: 45%).</p>
      <p>
        <bold>Discusi&#243;n</bold>
      </p>
      <p>En el presente art&#237;culo, realizamos una revisi&#243;n sistem&#225;tica con metan&#225;lisis para evaluar el impacto del implante de <italic>stents</italic> coronarios guiados por USIC en resultados de largo plazo. Nuestros resultados demostraron una reducci&#243;n significativa de 38% en los casos de RLB y 27% en la reestenosis angiogr&#225;fica con esa estrategia, pero ninguna diferencia estad&#237;sticamente significativa en el total de casos de ECVM, &#243;bito o infarto de miocardio.</p>
      <p>En la pr&#225;ctica de cardiolog&#237;a intervencionista actual, la penetraci&#243;n del USIC se present&#243; bastante heterog&#233;nea, de acuerdo con la experiencia y preferencia de cada centro y cada cirujano. Las m&#225;s recientes Directrices para Intervenci&#243;n Coronaria Percut&#225;nea atribuyen la recomendaci&#243;n clase IIa nivel de evidencia B para el implante de <italic>stent</italic> coronario guiado por USIC<sup>21</sup>. Nuestros resultados pueden servir para fortalecer esa recomendaci&#243;n, teniendo en vista que reestenosiss angiogr&#225;ficas y cl&#237;nicas fueron significativamente reducidas con el empleo de USIC.</p>
      <p>El costo de esa tecnolog&#237;a, con todo, tambi&#233;n debe ser tenido en cuenta. Considerando el NNT para evitar una RLB (20) y el costo adicional para incluir el USIC en un procedimiento de ICP (alrededor de R$ 2 mil), ser&#237;an necesarios R$ 40 mil para evitar una RLB.</p>
      <p>Tambi&#233;n es importante considerar si el USIC debe ser hecho en todos los pacientes, o apenas en aquellos con alto riesgo de reestenosis. Nuestro an&#225;lisis no provee ninguna informaci&#243;n sobre la existencia de subgrupos con mayores beneficios, sin embargo sugiere que pacientes con mayor complejidad pueden beneficiarse m&#225;s. La relaci&#243;n costo-beneficio de las intervenciones destinadas a reducir la repetici&#243;n de las revascularizaciones tambi&#233;n es favorable en aquellos con elevados riesgos basales de reestenosis<sup>22</sup>.</p>
      <p>Actualmente, los<italic> stents</italic> farmacol&#243;gicos son recomendados para la reducci&#243;n de la reestenosis/reoclusi&#243;n, con tanto que no haya contraindicaci&#243;n para terapias antiplaquetarias dobles prolongadas<sup>23-26</sup>. Nuestro estudio no abord&#243; la cuesti&#243;n sobre si el implante de rutina de <italic>stent</italic> guiado por USIC es mejor que la angiograf&#237;a aislada cuando un <italic>stent</italic> farmacol&#243;gico es implantado<sup>19</sup>. Aunque algunos de los predictores de reestenosis despu&#233;s de la implantaci&#243;n de <italic>stents</italic> farmacol&#243;gicos o <italic>stents</italic> de metal simples sean similares<sup>27,28</sup>, la extrapolaci&#243;n de los datos de una poblaci&#243;n a otra puede no ser apropiada. Con todo, se debe considerar en nuestros resultados que no todos los pacientes, en la pr&#225;ctica diaria, ser&#225;n buenos candidatos para recibir un <italic>stent</italic> farmacol&#243;gico. Pacientes con contraindicaciones o baja adhesi&#243;n a la terapia antiplaquetaria doble de largo plazo, cirug&#237;a no card&#237;aca planeada y comorbilidades asociadas con riesgo elevado de hemorragia representan algunas de esas situaciones<sup>24,29-32</sup>.</p>
      <p>Los an&#225;lisis de sensibilidad realizados no alteraron los resultados globales del metan&#225;lisis. Frey et al<sup>18</sup> realizaron un estudio cl&#237;nico randomizado con implante de <italic>stent</italic> provisorio guiado por USIC <italic>versus </italic>tratamiento convencional, pero no todos los pacientes recibieron el implante de <italic>stent</italic>. Decidimos incluir ese ensayo en ese metan&#225;lisis, y el an&#225;lisis de sensibilidad que promovi&#243; la retirada de ese estudio no alter&#243; los resultados para ECVM, mortalidad, infarto de miocardio, reestenosis angiogr&#225;fica y RLB. El estudio realizado por Jakabcin et al<sup>19</sup> adopt&#243; implante de rutina de <italic>stent</italic> farmacol&#243;gico por protocolo. Siendo as&#237;, tambi&#233;n decidimos incluir los datos de ese ensayo. En el an&#225;lisis de sensibilidad donde ese estudio fue removido, los resultados no se alteraron.</p>
      <p>Nuestro estudio presenta diversos puntos fuertes del punto de vista metodol&#243;gico, a saber: 1. Cuesti&#243;n de investigaci&#243;n enfocada; 2. Investigaci&#243;n bibliogr&#225;fica abarcadora y sistem&#225;tica; y 3. La colaboraci&#243;n de un equipo multidisciplinario de cardi&#243;logos intervencionistas, investigadores de salud y metod&#243;logos, que utilizaron criterios de elegibilidad expl&#237;citos y reproducibles y duplicaron decisiones de elegibilidad altamente independientes y reproducibles, adem&#225;s de las extracciones de datos. El metan&#225;lisis fue utilizado para expresar cuantitativamente los resultados obtenidos y evaluar la calidad de las evidencias para cada resultado analizado. Otro punto fuerte importante de este informe es que calculamos el tama&#241;o de la muestra (n&#250;mero ideal de informaciones) necesario para nuestro metan&#225;lisis de forma de determinar si las evidencias presentadas en nuestro metan&#225;lisis eran confiables y conclusivas.</p>
      <p>Casella et al<sup>33</sup> tambi&#233;n condujeron un metan&#225;lisis en ese campo, que fue publicado hace muchos a&#241;os. El trabajo consist&#237;a en apenas cinco ECR (n = 1.883), al tiempo que la presente revisi&#243;n consisti&#243; en tres ECR adicionales, totalizando ocho ensayos cl&#237;nicos (n = 2.341). Considerando apenas el an&#225;lisis de los ECR de la primera revisi&#243;n<sup>33</sup>, el implante de <italic>stent</italic> guiado por USIC no redujo los casos de ECVM (OR: 0,82, IC 95%: 0,64-1,04), &#243;bitos (OR: 1,27, IC 95%: 0,47-3,42) o infarto de miocardio (OR: 0,96, IC 95%: 0,59-1,56), semejante a los resultados del presente estudio. Mientras tanto, no observamos tasas menores de reestenosis con implante de <italic>stent</italic> guiado por USIC en comparaci&#243;n al implante de <italic>stent</italic> guiado por angiograf&#237;a, lo que no fue reportado por Casella et al<sup>33</sup> (OR: 0,81, IC 95%: 0,62-1,06). Se debe resaltar que nuestra revisi&#243;n sistem&#225;tica incluy&#243; apenas ERC y present&#243; mayor n&#250;mero de estudios en comparaci&#243;n con el estudio de Casella et al<sup>33</sup>, lo que debe haber contribuido a una mejor estimativa de los datos encontrados por nuestro grupo.</p>
      <p>Parise et al<sup>34</sup> tambi&#233;n realizaron una revisi&#243;n sistem&#225;tica de ese t&#243;pico recientemente. En su art&#237;culo, los resultados relacionados a reestenosis fueron semejantes, sin embargo los autores tambi&#233;n encontraron un beneficio del USIC en la reducci&#243;n de los casos de ECVM (OR 0,72, IC 95%: 0,52-0,99), lo que no fue presentado en nuestro an&#225;lisis. La principal diferencia entre esos dos metan&#225;lisis es la omisi&#243;n de los datos de casos de ECVM en el ensayo RESIST en nuestros c&#225;lculos<sup>20</sup>, lo que, en su publicaci&#243;n, no present&#243; la definici&#243;n de ECVM. De hecho, una publicaci&#243;n secundaria del ensayo sugiere que los n&#250;meros usados por Parise et al.<sup>34</sup> en su art&#237;culo incluyeron apenas revascularizaci&#243;n y &#243;bito, lo que no entra en nuestra definici&#243;n (y en la definici&#243;n de otros ensayos) de ECVM, que inclu&#237;a infarto de miocardio<sup>35</sup>. Adem&#225;s de eso, nuestro an&#225;lisis basado en el abordaje GRADE sugiere evidencias de baja calidad para ese resultado, y nuestro c&#225;lculo del n&#250;mero ideal de informaciones muestra que la cuesti&#243;n sobre el beneficio del USIC en relaci&#243;n a ECVM est&#225; lejos de ser respondida de forma adecuada.</p>
      <p>Algunas limitaciones presentes en nuestro estudio merecen ser destacadas. Primeramente, la mayor&#237;a de los estudios incluidos en nuestra revisi&#243;n sistem&#225;tica pueden no representar la pr&#225;ctica de ICP anual, teniendo en vista que los <italic>stents</italic> utilizados en los ensayos no son los <italic>stents</italic> empleados actualmente. Las t&#233;cnicas de ICP cambiaron considerablemente, los cardi&#243;logos intervencionistas poseen m&#225;s experiencia hoy que antes, la terapia antiplaquetaria es m&#225;s agresiva y la complejidad de los casos aument&#243;<sup>25</sup>. Adem&#225;s de eso, la dimensi&#243;n de la muestra no era la ideal, teniendo en vista que el total de datos disponibles sobre ECVM representa apenas 47% del n&#250;mero ideal de informaciones necesarias para detectar, con confiabilidad, un efecto de tratamiento plausible. Mientras tanto, con m&#225;s estudios y con un n&#250;mero mayor de pacientes, el implante de <italic>stent</italic> guiado por USIC puede reducir significativamente los casos de ECVM, teniendo en vista que el valor de p para este an&#225;lisis fue 0,08.</p>
      <p>
        <bold>Conclusiones</bold>
      </p>
      <p>Esta revisi&#243;n sistem&#225;tica y metan&#225;lisis demuestra que el implante de <italic>stent</italic> guiado por USIC reduce la reestenosis angiogr&#225;fica y RLB en comparaci&#243;n con el implante de <italic>stent</italic> guiado por angiograf&#237;a, sin embargo no reduce los casos de ECVM. Esos datos pueden proveer un soporte mayor al uso de USIC, pero la realizaci&#243;n de ECRs de mayor escala y de alta calidad es necesaria a fin de elucidar el posible beneficio del USIC en relaci&#243;n a los desenlaces duros.</p>
      <p>
        <bold>Potencial Conflicto de Intereses</bold>
      </p>
      <p>Declaro no haber conflicto de intereses pertinentes.</p>
      <p>
        <bold>Fuentes de Financiaci&#243;n</bold>
      </p>
      <p>CNPq y CAPES financiaron el presente estudio.</p>
      <p>
        <bold>Vinculaci&#243;n Acad&#233;mica</bold>
      </p>
      <p>No hay vinculaci&#243;n de este estudio a programas de postgrado.</p>
      <p>
        <bold>Referencias</bold>
      </p>
    </body>
  </sub-article>
</article>
