<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="letter">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">bZB8n8zN7m5MVWVxK6cv4Jc</article-id>
      <article-id pub-id-type="other">00006</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2011000500006</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(11)09600506</article-id>
      <article-id pub-id-type="doi">10.1590/S0066-782X2011005000036</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigos Originais</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Curva de refer&#234;ncia da &#225;rea do septo interventricular fetal pelo m&#233;todo STIC: estudo preliminar</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Rolo</surname>
            <given-names>Liliam Cristine</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Nardozza</surname>
            <given-names>Luciano Marcondes Machado</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Araujo J&#250;nior</surname>
            <given-names>Edward</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Simioni</surname>
            <given-names>Christiane</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Zamith</surname>
            <given-names>Marina Maccagnano</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Moron</surname>
            <given-names>Antonio Fernandes</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <addr-line>
          <named-content content-type="city">S&#227;o Paulo</named-content>
          <named-content content-type="state">S&#227;o Paulo</named-content>
        </addr-line>
        <institution content-type="orgname">Universidade Federal de S&#227;o Paulo</institution>
        <institution content-type="orgdiv1">Departamento de Obstetr&#237;cia </institution>
        <country country="BR">Brazil</country>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>05</month>
        <year>2011</year>
      </pub-date>
      <volume>96</volume>
      <issue>5</issue>
      <fpage>386</fpage>
      <lpage>392</lpage>
      <history>
        <date date-type="received">
          <day>29</day>
          <month>07</month>
          <year>2010</year>
        </date>
        <date date-type="rev-recd">
          <day>17</day>
          <month>11</month>
          <year>2010</year>
        </date>
        <date date-type="accepted">
          <day>14</day>
          <month>12</month>
          <year>2010</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <abstract>
        <p>FUNDAMENTO: A detec&#231;&#227;o precoce de altera&#231;&#245;es septais, tais como a hipertrofia septal comumente presente em fetos de m&#227;es diab&#233;ticas, contribuiria para a redu&#231;&#227;o das altas taxas de mortalidade infantil. OBJETIVO: Determinar intervalos de refer&#234;ncia para a &#225;rea do septo interventricular fetal por meio da ultrassonografia tridimensional (US3D) utilizando o m&#233;todo STIC (Spatio-Temporal Image Correlation). M&#201;TODOS: Realizou-se um estudo de corte transversal com 69 gestantes normais entre a 18&#170; e 33&#170; semanas de gesta&#231;&#227;o. Utilizou-se como refer&#234;ncia o plano de quatro c&#226;maras com a ROI (Regi&#227;o de Interesse) posicionada a partir dos ventr&#237;culos, sendo a &#225;rea do septo delimitada de modo manual. Para se avaliar a correla&#231;&#227;o da &#225;rea do septo interventricular com a idade gestacional (IG), constru&#237;ram-se diagramas de dispers&#227;o e calculou-se o coeficiente de correla&#231;&#227;o de Pearson (r), sendo o ajuste realizado pelo coeficiente de determina&#231;&#227;o (R&#178;). Foram calculadas m&#233;dias, medianas, desvios-padr&#227;o (dp), valores m&#225;ximo e m&#237;nimo. Para o c&#225;lculo da reprodutibilidade intraobservador, utilizou-se o coeficiente de correla&#231;&#227;o intraclasse (CCI). Obteve-se a medida da espessura do septo interventricular e ela foi correlacionada com a IG e a &#225;rea septal obtida pelo modo renderizado em 52 pacientes utilizando-se o CCI. RESULTADOS: A &#225;rea do septo interventricular foi altamente correlacionada com a idade gestacional (r = 0,81), e a m&#233;dia aumentou de 0,47 cm&#178; na 18&#170; para 2,42 cm&#178; na 33&#170; semana de gesta&#231;&#227;o. A reprodutibilidade intraobservador foi excelente com CCI = 0,994. N&#227;o se observou correla&#231;&#227;o significativa entre a medida do septo interventricular e a IG (R&#178; = 0,200), assim como n&#227;o houve correla&#231;&#227;o com a &#225;rea do septo obtida pelo modo renderizado com CCI = 0,150. CONCLUS&#195;O: Intervalos de refer&#234;ncia para a &#225;rea do septo interventricular entre a 18&#170; e 33&#170; semanas de gesta&#231;&#227;o foram determinados e se mostraram altamente reprodut&#237;veis.</p>
      </abstract>
      <kwd-group xml:lang="pt" kwd-group-type="author-generated">
        <kwd>Gravidez</kwd>
        <kwd>cora&#231;&#227;o fetal</kwd>
        <kwd>septo interventricular</kwd>
        <kwd>valores de refer&#234;ncia</kwd>
        <kwd>imagem tridimensional</kwd>
      </kwd-group>
      <pub-date publication-format="electronic" date-type="pub">
        <day>01</day>
        <month>04</month>
        <year>2011</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>
      <bold>ARTIGO ORIGINAL</bold>
    </p>
    <p>
      <bold>Curva de refer&#234;ncia da &#225;rea do septo interventricular fetal pelo m&#233;todo STIC: estudo preliminar</bold>
    </p>
    <p>
      <bold>Liliam Cristine Rolo; Luciano Marcondes Machado Nardozza; Edward Araujo J&#250;nior; Christiane Simioni; Marina Maccagnano Zamith; Antonio Fernandes Moron</bold>
    </p>
    <p>Departamento de Obstetr&#237;cia - Universidade Federal de S&#227;o Paulo, S&#227;o Paulo, SP - Brasil</p>
    <p>
      <xref ref-type="corresp" rid="back">Correspond&#234;ncia</xref>
    </p>
    <p>
      <bold>RESUMO</bold>
    </p>
    <p><bold>FUNDAMENTO: </bold> A detec&#231;&#227;o precoce de altera&#231;&#245;es septais, tais como a hipertrofia septal comumente presente em fetos de m&#227;es diab&#233;ticas, contribuiria para a redu&#231;&#227;o das altas taxas de mortalidade infantil. </p>
    <p><bold>OBJETIVO: </bold> Determinar intervalos de refer&#234;ncia para a &#225;rea do septo interventricular fetal por meio da ultrassonografia tridimensional (US3D) utilizando o m&#233;todo STIC (<italic>Spatio-Temporal Image Correlation</italic>). </p>
    <p><bold>M&#201;TODOS: </bold> Realizou-se um estudo de corte transversal com 69 gestantes normais entre a 18&#170; e 33&#170; semanas de gesta&#231;&#227;o. Utilizou-se como refer&#234;ncia o plano de quatro c&#226;maras com a ROI (Regi&#227;o de Interesse) posicionada a partir dos ventr&#237;culos, sendo a &#225;rea do septo delimitada de modo manual. Para se avaliar a correla&#231;&#227;o da &#225;rea do septo interventricular com a idade gestacional (IG), constru&#237;ram-se diagramas de dispers&#227;o e calculou-se o coeficiente de correla&#231;&#227;o de Pearson (r), sendo o ajuste realizado pelo coeficiente de determina&#231;&#227;o (R<sup>2</sup>). Foram calculadas m&#233;dias, medianas, desvios-padr&#227;o (dp), valores m&#225;ximo e m&#237;nimo. Para o c&#225;lculo da reprodutibilidade intraobservador, utilizou-se o coeficiente de correla&#231;&#227;o intraclasse (CCI). Obteve-se a medida da espessura do septo interventricular e ela foi correlacionada com a IG e a &#225;rea septal obtida pelo modo renderizado em 52 pacientes utilizando-se o CCI. </p>
    <p><bold>RESULTADOS: </bold> A &#225;rea do septo interventricular foi altamente correlacionada com a idade gestacional (r = 0,81), e a m&#233;dia aumentou de 0,47 cm<sup>2</sup> na 18&#170; para 2,42 cm<sup>2</sup> na 33&#170; semana de gesta&#231;&#227;o. A reprodutibilidade intraobservador foi excelente com CCI = 0,994. N&#227;o se observou correla&#231;&#227;o significativa entre a medida do septo interventricular e a IG (R&#178; = 0,200), assim como n&#227;o houve correla&#231;&#227;o com a &#225;rea do septo obtida pelo modo renderizado com CCI = 0,150. </p>
    <p><bold>CONCLUS&#195;O: </bold> Intervalos de refer&#234;ncia para a &#225;rea do septo interventricular entre a 18&#170; e 33&#170; semanas de gesta&#231;&#227;o foram determinados e se mostraram altamente reprodut&#237;veis.</p>
    <p><bold>Palavras-chave: </bold> Gravidez, cora&#231;&#227;o fetal, septo interventricular, valores de refer&#234;ncia, imagem tridimensional.</p>
    <p>
      <bold>Introdu&#231;&#227;o</bold>
    </p>
    <p>O aumento progressivo da demanda de oxig&#234;nio em raz&#227;o do r&#225;pido crescimento do embri&#227;o durante as fases iniciais da embriog&#234;nese determina a precoce forma&#231;&#227;o card&#237;aca por volta do 22&#186;-23&#186; dias de gesta&#231;&#227;o<sup>1</sup>. Progressivamente, o cora&#231;&#227;o primitivo fetal sofre uma s&#233;rie de processos remodeladores capazes de modificar a sua anatomia, at&#233; atingir a forma funcional que conhecemos<sup>1</sup>.</p>
    <p>O cora&#231;&#227;o, quando j&#225; composto de suas quatro c&#226;maras (&#225;trios e ventr&#237;culos), apresenta no interior de seus ventr&#237;culos o septo interventricular (IV) divisor, formado a partir da fus&#227;o das paredes mediais: a parte muscular do septo IV. Dentro dos ventr&#237;culos, com a cavita&#231;&#227;o dos mesmos, os feixes musculares ser&#227;o formados e esses originam os m&#250;sculos papilares e as cordas tend&#237;neas<sup>1</sup>, com fun&#231;&#227;o de compet&#234;ncia valvar, impedindo o prolapso das c&#250;spides durante a s&#237;stole card&#237;aca e o refluxo sangu&#237;neo<sup>2</sup>.</p>
    <p>Em 50% dos casos, as malforma&#231;&#245;es card&#237;acas s&#227;o consideradas defeitos maiores, fatores determinantes da eleva&#231;&#227;o da taxa da mortalidade infantil precoce e tardia<sup>3,4</sup>, evidenciando a necessidade do rastreamento e diagn&#243;stico precoce de tais cardiopatias. Apesar da ampla aplica&#231;&#227;o da ultrassonografia convencional no rastreamento de cardiopatias cong&#234;nitas, a detec&#231;&#227;o pr&#233;-natal ainda apresenta lacunas diagn&#243;sticas, o que impulsiona o desenvolvimento de novas t&#233;cnicas de aquisi&#231;&#227;o de imagem para um melhor rastreamento card&#237;aco durante a rotina do pr&#233;-natal<sup>5-7</sup>.</p>
    <p>Nas &#250;ltimas d&#233;cadas, com o desenvolvimento da ultrassonografia tridimensional (US3D) e da tecnologia do <italic>Spatio-Temporal Image Correlation</italic> (STIC), surgiu uma nova forma de an&#225;lise card&#237;aca pr&#233;-natal. Tal t&#233;cnica permite a obten&#231;&#227;o do volume card&#237;aco e seu armazenamento para posterior reconstru&#231;&#227;o e an&#225;lise da sua anatomia, apresentando a imagem no modo multiplanar e de superf&#237;cie (renderizada), identificando-se as c&#226;maras card&#237;acas, as v&#225;lvulas atrioventriculares e semilunares, al&#233;m do posicionamento dos vasos e suas correla&#231;&#245;es, podendo-se tamb&#233;m acompanhar o movimento card&#237;aco pelo uso da t&#233;cnica do <italic>cineloop</italic><sup>7-9</sup>.</p>
    <p>Apesar dos in&#250;meros trabalhos desenvolvidos com a t&#233;cnica de STIC, n&#227;o se encontra na literatura a sua aplica&#231;&#227;o na avalia&#231;&#227;o da medida da &#225;rea do septo interventricular em cora&#231;&#245;es de fetos normais e/ou cardiopatas. Essa medida seria uma forma de analisar diretamente os defeitos septais, que s&#227;o os defeitos card&#237;acos cong&#234;nitos mais comumente encontrados, perfazendo cerca de 30% das doen&#231;as card&#237;acas, em especial os defeitos membran&#225;ceos<sup>1</sup>, al&#233;m de analisar indiretamente as demais malforma&#231;&#245;es card&#237;acas (como as estenoses valvares com consequentes hipertrofias ventriculares dentre outras). Al&#233;m disso, a medida da &#225;rea valvar possibilitar&#225; a detec&#231;&#227;o precoce da hipertrofia septal nos fetos de gestantes diab&#233;ticas, rastreando fetos com maior probabilidade de desenvolvimento de macrossomia e cardiomiopatia<sup>10,11</sup>.</p>
    <p>Este estudo tem por objetivo determinar valores de refer&#234;ncia para a &#225;rea do septo interventricular de fetos normais entre a 18&#170; e a 33&#170; semanas de gesta&#231;&#227;o por meio da US3D utilizando o m&#233;todo STIC.</p>
    <p>
      <bold>M&#233;todos</bold>
    </p>
    <p>Realizou-se um estudo do tipo corte transversal, entre dezembro de 2009 e maio de 2010, com 69 gestantes entre a 18&#170; e a 33&#170; semanas completas de gesta&#231;&#227;o. Este estudo foi aprovado pelo Comit&#234; de &#201;tica em Pesquisa da Universidade Federal de S&#227;o Paulo (Unifesp) sob o n<sup>0</sup> 0135/10, e as pacientes que concordaram na participa&#231;&#227;o volunt&#225;ria assinaram Termo de Consentimento Livre e Esclarecido.</p>
    <p>Todas as pacientes foram selecionadas no setor de pr&#233;-natal de baixo risco do Departamento de Obstetr&#237;cia da Unifesp, sendo essas oriundas do Sistema &#218;nico de Sa&#250;de do munic&#237;pio e da regi&#227;o metropolitana da cidade de S&#227;o Paulo. Os crit&#233;rios de inclus&#227;o foram os seguintes: gesta&#231;&#227;o &#250;nica com embri&#227;o vivo e idade gestacional determinada pela data da &#250;ltima menstrua&#231;&#227;o (DUM) e confirmada por ultrassonografia realizada at&#233; a 10&#170; semana utilizando como par&#226;metro o Comprimento Cabe&#231;a-N&#225;dega (CCN). Os crit&#233;rios de exclus&#227;o foram: oligo&#226;mnio [&#205;ndice de L&#237;quido Amni&#243;tico (ILA) abaixo do percentil 5 para a idade gestacional, segundo tabela proposta por Moore e Cayle<sup>12</sup>; feto posicionado com o dorso anterior (entre 11 e 1h); fetos com peso estimado abaixo e/ou acima de dois desvios-padr&#227;o da m&#233;dia, de acordo com a tabela proposta de Hadlock; gestantes portadoras de doen&#231;as cr&#244;nicas que pudessem afetar o crescimento e desenvolvimento fetal, tais como hipertens&#227;o arterial, diabete melito, colagenoses, entre outras; atenua&#231;&#227;o intensa do feixe sonoro por condi&#231;&#245;es tais como obesidade materna e cicatrizes abdominais; malforma&#231;&#227;o fetal diagnosticada &#224; ultrassonografia morfol&#243;gica de 1&#186; e 2&#186; trimestres; pacientes tabagistas e/ou usu&#225;rias de drogas il&#237;citas. Todas as gestantes foram submetidas a ecocardiografia fetal realizada entre 20 e 24 semanas de gesta&#231;&#227;o.</p>
    <p>Todos os exames foram realizados no Setor de Cardiologia Fetal do Departamento de Obstetr&#237;cia da Unifesp, sendo esses realizados por apenas um examinador (LCR) com experi&#234;ncia de tr&#234;s anos em US3D em obstetr&#237;cia. Todos os exames foram realizados em um aparelho da marca Voluson 730 Expert (General Eletric Medical Systems, Kretztechnic, Zipf, Austria) equipado com um transdutor convexo volum&#233;trico (RAB4-8P). As an&#225;lises <italic>off-line</italic> para a mensura&#231;&#227;o das &#225;reas do septo interventricular foram realizadas pelo mesmo examinador utilizando o <italic>software</italic> 4D <italic>View</italic> vers&#227;o 9.0 (GE, Medical Systems Kretztechnic, GmbH &amp; Co OHG).</p>
    <p>Os volumes card&#237;acos foram colhidos no corte das 4 c&#226;maras card&#237;acas com o dorso fetal, se poss&#237;vel, na posi&#231;&#227;o de 6 horas, utilizando-se um &#226;ngulo de abertura entre 20 e 40<sup>0</sup> e um tempo de aquisi&#231;&#227;o entre 10 e 15 segundos. Ap&#243;s a varredura tridimensional, a imagem foi apresentada na tela do aparelho na forma de tr&#234;s planos ortogonais: axial (A), sagital (B) e coronal (C). Antes de se iniciar as avalia&#231;&#245;es, foi utilizada a padroniza&#231;&#227;o proposta por Paladini<sup>13</sup> para a orienta&#231;&#227;o de volumes obtidos pelo STIC, ou seja, para fetos em apresenta&#231;&#227;o cef&#225;lica, o lado esquerdo do cora&#231;&#227;o coincide com o lado esquerdo da tela, enquanto para os fetos p&#233;lvicos, o lado esquerdo do cora&#231;&#227;o coincide com o lado direito da tela; devendo-se o plano A ser rodado 180<sup>0</sup> em torno do eixo "Y".</p>
    <p>O plano das quatro c&#226;maras card&#237;acas (A) foi selecionado como referencial, sendo esse rodado em torno do eixo "Z", de forma que o &#225;pice card&#237;aco se depusesse em 6 horas; em seguida, foi ativada a tecla RENDER, com ponto de refer&#234;ncia da caixa disposta no ter&#231;o m&#233;dio do septo interventricular. Tr&#234;s planos virtuais para avalia&#231;&#227;o do septo interventricular foram utilizados. Dois planos foram determinados pelo posicionamento da linha verde (ativa) da caixa de renderiza&#231;&#227;o paralelo &#224; borda externa do septo interventricular, com o ponto m&#233;dio mantido no seu ter&#231;o m&#233;dio. Utilizou-se a op&#231;&#227;o seis da ROI <italic>selection</italic>, delimitando-se a regi&#227;o do septo; por conven&#231;&#227;o, optou-se pela sua visibiliza&#231;&#227;o atrav&#233;s do lado do ventr&#237;culo esquerdo. A imagem renderizada foi magnificada e ent&#227;o a tecla MEASURE foi acionada e a op&#231;&#227;o TRACE AREA foi selecionada para se delimitar manualmente a &#225;rea septal em cm&#178;. A mensura&#231;&#227;o da &#225;rea septal foi realizada durante a fase inicial da di&#225;stole ventricular, momento em que o septo encontrava-se menos contra&#237;do (<xref ref-type="fig" rid="aop02811f01">Figura 1</xref>). A medida bidimensional da espessura septal tamb&#233;m foi obtida no plano de quatro c&#226;maras em mm (<xref ref-type="fig" rid="aop02811f02">Figura 2</xref>).</p>
    <p content-type="asset">
      <fig id="aop02811f01">
        <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf01.jpg"/></fig>
    </p>
    <p content-type="asset">
      <fig id="aop02811f02">
        <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf02.jpg"/></fig>
    </p>
    <p>Os dados foram armazenados em planilha do programa Excel (Microsoft, Redmond, WA, USA) e analisados por meio de um programa estat&#237;stico <italic>Statistical Package for the Social Sciences</italic> (SPSS) for Windows vers&#227;o 15.0 (SPSS Inc., Chicago, IL, USA). Foram calculadas m&#233;dias, medianas, desvios-padr&#227;o (dp), valores m&#225;ximo e m&#237;nimo para cada intervalo gestacional avaliado, bem como os percentis 5, 25, 50, 75 e 95. Para se avaliar a correla&#231;&#227;o entre as &#225;reas do septo interventricular com a idade gestacional (IG), foram determinados diagramas de dispers&#227;o obtendo-se &#237;ndice de correla&#231;&#227;o de Pearson (r), sendo o ajuste da equa&#231;&#227;o determinado pelo coeficiente de determina&#231;&#227;o (R<sup>2</sup>). Para a constru&#231;&#227;o de intervalos de refer&#234;ncia das &#225;reas do septo interventricular em fun&#231;&#227;o da idade gestacional, seguiu-se o modelo de regress&#227;o linear simples<sup>14</sup>, utilizando-se o m&#233;todo de Altman<sup>15</sup> com n&#237;vel de signific&#226;ncia de p &lt; 0,05. Para se avaliar a medida da espessura septal em fun&#231;&#227;o da idade gestacional utilizou-se tamb&#233;m a regress&#227;o linear. Para se avaliar a correla&#231;&#227;o entre a medida da espessura bidimensional do septo interventricular e a sua &#225;rea, utilizou-se o coeficiente de correla&#231;&#227;o intraclasse (CCI). Para o c&#225;lculo da reprodutibilidade intraobservador, o mesmo examinador (LCR) realizou uma segunda medida da &#225;rea septal de 40 fetos, medidas essas blindadas dos resultados da primeira. Para tanto, tamb&#233;m se utilizou o CCI e o gr&#225;fico de Bland-Altman<sup>16</sup>. Os gr&#225;ficos de Bland-Altman plotam as m&#233;dias duas medidas, realizadas por um mesmo examinador, contra a diferen&#231;a de suas m&#233;dias com intervalo de 95% de confian&#231;a de 1,96 dp da m&#233;dia. Em todas as an&#225;lises ser&#225; utilizado n&#237;vel de signific&#226;ncia de 0,05.</p>
    <p>
      <bold>Resultados</bold>
    </p>
    <p>Foram avaliadas 69 gestantes portando fetos normais entre a 18&#170; e a 33&#170; semanas completas da gesta&#231;&#227;o, e todas preencheram os crit&#233;rios de inclus&#227;o e foram alocadas na an&#225;lise estat&#237;stica final. A idade materna em m&#233;dia foi de 29,8 anos com dp &#177; 5,1, com m&#233;dia de 1,4 gesta&#231;&#245;es (dp &#177; 0,5) e paridade m&#233;dia de 0,3 partos (dp &#177; 0,5).</p>
    <p>A &#225;rea m&#233;dia da &#225;rea septal foi de 0,47 &#177; 0,10 cm<sup>2</sup> (variando de 0,36 - 0,59 cm<sup>2</sup>) na 18&#170; semana para 2,42 &#177; 1,13 cm<sup>2</sup> (variando de 1,26 - 3,92 cm<sup>2</sup>) na 33&#170; semana de gesta&#231;&#227;o. A <xref ref-type="table" rid="t1">tabela 1</xref> mostra m&#233;dias, medianas, desvios-padr&#227;o e valores m&#237;nimos e m&#225;ximos da &#225;rea do septo interventricular, enquanto a <xref ref-type="table" rid="t2">tabela 2</xref> mostra os percentis 5, 25, 50, 75 e 95 em cada intervalo gestacional avaliado.</p>
    <table-wrap id="t1">
      <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gt01.jpg"/></table-wrap>
    <table-wrap id="t2">
      <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gt02.jpg"/></table-wrap>
    <p>A &#225;rea septal apresentou forte correla&#231;&#227;o com a idade gestacional (r = 0,81). Foram realizados modelos de regress&#227;o polinomial, sendo o melhor ajuste com a equa&#231;&#227;o exponencial: &#225;rea do septo interventricular = 0,125 x IG + 0,043, com R<sup>2</sup>=0,65 (<xref ref-type="fig" rid="f3">Figura 3</xref>).</p>
    <fig id="f3">
      <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf03.jpg"/></fig>
    <p>Em 52 pacientes, a medida da espessura septal foi obtida no modo bidimensional, mas n&#227;o apresentou correla&#231;&#227;o significativa com a idade gestacional (R&#178; = 0,20), mostrando um padr&#227;o praticamente linear entre a 18&#170; e a 33&#170; semanas completas de gesta&#231;&#227;o (<xref ref-type="fig" rid="f4">Figura 4</xref>). Al&#233;m disso, n&#227;o houve correla&#231;&#227;o estatisticamente significante entre a medida da espessura e da &#225;rea septal no intervalo gestacional estudado com CCI= 0,150 [95% IC -0,480; 0,512], com p &lt; 0,005.</p>
    <fig id="f4">
      <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf04.jpg"/></fig>
    <p>Observou-se uma excelente reprodutibilidade intraobservador para a medida da &#225;rea do septo interventricular, com CCI= 0,994 (IC 95% 0,988 - 0,997). O gr&#225;fico de Bland-Altman comprovou essa boa reprodutibilidade com diferen&#231;a m&#233;dia entre as medidas de 0,01 cm<sup>2</sup> (dp &#177; 0,06 cm<sup>2</sup> e IC 95% &#177; 0,12 cm<sup>2</sup>) (<xref ref-type="fig" rid="f5">Figura 5</xref>).</p>
    <fig id="f5">
      <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf05.jpg"/></fig>
    <p>
      <bold>Discuss&#227;o</bold>
    </p>
    <p>A tecnologia STIC tem estado dispon&#237;vel em alguns aparelhos de US3D em meados da d&#233;cada de 2010. STIC consiste na aquisi&#231;&#227;o do volume do cora&#231;&#227;o fetal com suas conex&#245;es vasculares, permitindo a sua avalia&#231;&#227;o nos modo multiplanar ou renderizado na forma de uma sequ&#234;ncia "cineloop" de um ciclo card&#237;aco completo. Para a aquisi&#231;&#227;o do volume, deve-se selecionar uma regi&#227;o de interesse (ROI), que determina a altura e largura do volume, que englobe todo o cora&#231;&#227;o com suas conex&#245;es vasculares. Sempre que poss&#237;vel, a aquisi&#231;&#227;o deve ser realizada com o feto em dorso posterior (6 horas) e na aus&#234;ncia de movimentos respirat&#243;rios maternos. O &#226;ngulo de aquisi&#231;&#227;o, que determina a profundidade do volume, varia de acordo com a idade gestacional, e &#226;ngulos entre 20 e 25<sup>0</sup> s&#227;o suficientes em fetos no segundo trimestre. O tempo de aquisi&#231;&#227;o &#233; determinado pelo operador, variando de 7,5 a 15 segundos, e corresponde &#224; velocidade com que o transdutor varre a ROI. Ao volume em escala de cinzas, pode-se associar o modo Doppler colorido, al&#233;m de p&#243;s-processamentos como o "inversion mode" e o "B-flow imaging"<sup>8,17</sup>. A vantagem do STIC em rela&#231;&#227;o &#224; ecocardiografia bidimensional &#233; ser um m&#233;todo menos dependente do operador, possibilitando a identifica&#231;&#227;o de anormalidades nas vias de sa&#237;da do cora&#231;&#227;o fetal por examinadores com pouca a intermedi&#225;ria experi&#234;ncia<sup>18</sup>.</p>
    <p>Em rela&#231;&#227;o &#224; renderiza&#231;&#227;o de estruturas card&#237;acas, Yagel e cols.<sup>19</sup> avaliaram 136 gestantes, sendo 35 portando fetos com anomalias card&#237;acas, utilizando a renderiza&#231;&#227;o para obter planos para avalia&#231;&#227;o dos septos interatrial e interventricular, &#226;nulo das valvas atrioventriculares e alinhamento dos grandes vasos. Em 13 fetos com anomalias card&#237;acas, o plano do septo interventricular melhorou a avalia&#231;&#227;o do defeito septal, e em 4 o plano do septo interatrial contribuiu para avalia&#231;&#227;o do forame oval. Em 5 casos, o plano do &#226;nulo das valvas atrioventriculares imediatamente distais &#224;s valvas semilunares (coronal AV) melhorou a avalia&#231;&#227;o do alinhamento dos grandes vasos em rela&#231;&#227;o ao &#226;nulo das valvas atrioventriculares, e em 3 a avalia&#231;&#227;o das valvas semilunares, com ou sem mau alinhamento dos grandes vasos. Recentemente, Paladini e cols.<sup>20</sup> avaliaram uma s&#233;rie de 30 casos de defeitos parciais do septo atrioventricular fetal utilizando a ecocardiografia, e em 14 desses casos associou-se o STIC. Em todos os casos os marcadores ecocardiogr&#225;ficos para essa anomalia foram: defeito do septo atrial ostium primum e perda da apar&#234;ncia normal das valvas atrioventriculares.</p>
    <p>A medida da &#225;rea do septo interventricular &#233; de particular import&#226;ncia em fetos de risco para miocardiopatias hipertr&#243;ficas, como os filhos de m&#227;es diab&#233;ticas, nos quais h&#225; importante espessamento do septo interventricular, podendo causar obstru&#231;&#245;es no trato de sa&#237;da do ventr&#237;culo esquerdo<sup>21</sup>. A gravidade dos sintomas de insufici&#234;ncia respirat&#243;ria e fal&#234;ncia card&#237;aca congestiva se correlacionam com a severidade da miocardiopatia hipertr&#243;fica<sup>22,23</sup>. Tradicionalmente a medida da espessura do septo interventricular fetal tem sido realizada pela ecocardiografia bidimensional utilizando o modo M<sup>10,11,24</sup>; contudo, tal medida apresenta imprecis&#245;es, pois o septo interventricular n&#227;o &#233; uma estrutura uniforme.</p>
    <p>Neste estudo, utilizou-se a t&#233;cnica STIC para mensura&#231;&#227;o da &#225;rea do septo interventricular, metodologia at&#233; o momento in&#233;dita na literatura. A &#225;rea do septo mostrou-se fortemente correlacionada com a idade gestacional, al&#233;m de comprovada reprodutibilidade intraobservador. J&#225; a medida da espessura septal mostrou fraca correla&#231;&#227;o com a idade gestacional, mostrando um padr&#227;o praticamente linear da medida entre a 18&#170; e a 33&#170; semanas completas de gesta&#231;&#227;o, sem apresentar correla&#231;&#227;o estatisticamente significante com &#225;rea obtida pelo STIC. Tal resultado torna a &#225;rea septal um poss&#237;vel par&#226;metro ultrassonogr&#225;fico mais fidedigno que a medida da espessura do septo interventricular no diagn&#243;stico de hipertrofia septal.</p>
    <p>Em s&#237;ntese, este estudo determinou valores de refer&#234;ncia para a &#225;rea do septo interventricular fetal que poder&#227;o ser aplicados em fetos de risco para hipertrofia septal, como os filhos de m&#227;es diab&#233;ticas, favorecendo a detec&#231;&#227;o precoce de altera&#231;&#245;es funcionais e morfol&#243;gicas card&#237;acas fetais.</p>
    <p>
      <fn id="back" fn-type="corresp">
        <p>Correspond&#234;ncia:</p>
        <p> Edward Araujo J&#250;nior </p>
        <p> Rua Napole&#227;o de Barros, 875 - Vila Clementino </p>
        <p> 04024-002 - S&#227;o Paulo, SP - Brasil </p>
        <p> E-mail: </p>
        <p>
          <email xlink:href="araujojred@terra.com.br">araujojred@terra.com.br</email>
        </p>
      </fn>
    </p>
    <p>Artigo recebido em 29/07/10; revisado recebido em 17/11/10; aceito em 14/12/10.</p>
  </body>
  <back>
    <ref-list>
      <ref id="B1">
        <mixed-citation>1. Moore KL, Persaud    TVN. Embriologia b&#225;sica. Rio de Janeiro: Saunders/Elsevier; 2008.</mixed-citation>
        <element-citation publication-type="book">
          <source>Embriologia b&#225;sica</source>
          <date>
            <year>2008</year>
          </date>
          <person-group person-group-type="author">
            <name>
              <surname>Moore</surname>
              <given-names>KL</given-names>
            </name>
            <name>
              <surname>Persaud</surname>
              <given-names>TVN</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Hansen DE, Cahill    PD, DeCampli WM, Harrison DC, Derby GC, Mitchell RS. Valvular-ventricular intereaction:    importance of the mitral apparatus in canine left ventricular systolic performance.    Circulation. 1986;73(6):1310-20.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Valvular-ventricular intereaction: importance of the mitral apparatus in canine left ventricular systolic performance</article-title>
          <source>Circulation</source>
          <date>
            <year>1986</year>
          </date>
          <fpage>1310</fpage>
          <lpage>20</lpage>
          <issue>6</issue>
          <volume>73</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Hansen</surname>
              <given-names>DE</given-names>
            </name>
            <name>
              <surname>Cahill</surname>
              <given-names>PD</given-names>
            </name>
            <name>
              <surname>DeCampli</surname>
              <given-names>WM</given-names>
            </name>
            <name>
              <surname>Harrison</surname>
              <given-names>DC</given-names>
            </name>
            <name>
              <surname>Derby</surname>
              <given-names>GC</given-names>
            </name>
            <name>
              <surname>Mitchell</surname>
              <given-names>RS</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. McElhinney DB,    Silverman NH, Brook MM, Hanley FL, Stanger P. Asymmetrically short tendinous    cords causing congenital tricuspid regurgitation: improved understanding of    tricuspid valvular dysplasia in the era of color flow echocardiography. Cardiol    Young. 1999;9(3):300-4.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Asymmetrically short tendinous cords causing congenital tricuspid regurgitation: improved understanding of tricuspid valvular dysplasia in the era of color flow echocardiography</article-title>
          <source>Cardiol Young</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>300</fpage>
          <lpage>4</lpage>
          <issue>3</issue>
          <volume>9</volume>
          <person-group person-group-type="author">
            <name>
              <surname>McElhinney</surname>
              <given-names>DB</given-names>
            </name>
            <name>
              <surname>Silverman</surname>
              <given-names>NH</given-names>
            </name>
            <name>
              <surname>Brook</surname>
              <given-names>MM</given-names>
            </name>
            <name>
              <surname>Hanley</surname>
              <given-names>FL</given-names>
            </name>
            <name>
              <surname>Stanger</surname>
              <given-names>P</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Minami K, Kado    H, Sai S, Tatewaki H, Shiokawa Y, Nakashima A, et al. Midterm results of mitral    valve repair with artificial chordae in children. J Thorac Cardiovasc Surg.    2005;129(2):336-42.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Midterm results of mitral valve repair with artificial chordae in children</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <date>
            <year>2005</year>
          </date>
          <fpage>336</fpage>
          <lpage>42</lpage>
          <issue>2</issue>
          <volume>129</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Minami</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Kado</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Sai</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Tatewaki</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Shiokawa</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Nakashima</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. St&#252;mpflen    I, St&#252;mpflen A, Wimmer M, Bernaschek G. Effect of detailed echocardiography    as part of routine prenatal ultrasonographic screening on detection of congenital    heart disease. Lancet. 1996;348(9031):854-7.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Effect of detailed echocardiography as part of routine prenatal ultrasonographic screening on detection of congenital heart disease</article-title>
          <source>Lancet</source>
          <date>
            <year>1996</year>
          </date>
          <fpage>854</fpage>
          <lpage>7</lpage>
          <issue>9031</issue>
          <volume>348</volume>
          <person-group person-group-type="author">
            <name>
              <surname>St&#252;mpflen</surname>
              <given-names>I</given-names>
            </name>
            <name>
              <surname>St&#252;mpflen</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Wimmer</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Bernaschek</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B6">
        <mixed-citation>6. Berghella V,    Pagotto L, Kaufman M, Huhta JC, Wapner RJ. Accuracy of prenatal diagnosis of    congenital heart defects. Fetal Diagn Ther. 2001; 16(6):407-12.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Accuracy of prenatal diagnosis of congenital heart defects</article-title>
          <source>Fetal Diagn Ther</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>407</fpage>
          <lpage>12</lpage>
          <issue>6</issue>
          <volume>16</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Berghella</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Pagotto</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Kaufman</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Huhta</surname>
              <given-names>JC</given-names>
            </name>
            <name>
              <surname>Wapner</surname>
              <given-names>RJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B7">
        <mixed-citation>7. Kurjak A, Chervenak    FA. Donald School Textbook of Ultrasound in Obstetrics and Ginecology. New Delhi:    Jaypee Brothers Medical Publishers (P) Ltd; 2008.</mixed-citation>
        <element-citation publication-type="book">
          <source>Donald School Textbook of Ultrasound in Obstetrics and Ginecology</source>
          <date>
            <year>2008</year>
          </date>
          <person-group person-group-type="author">
            <name>
              <surname>Kurjak</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Chervenak</surname>
              <given-names>FA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B8">
        <mixed-citation>8. Gon&#231;alves    LF, Lee W, Chaiworapongsa T, Espinoza J, Schoen MJ, Falkensammer P, et al. Four-dimensional    ultrasonography of the fetal heart with spatiotemporal image correlation. Am    J Obstet Gynecol. 2003;189(6):1792-802.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation</article-title>
          <source>Am J Obstet Gynecol</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>1792</fpage>
          <lpage>802</lpage>
          <issue>6</issue>
          <volume>189</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Gon&#231;alves</surname>
              <given-names>LF</given-names>
            </name>
            <name>
              <surname>Lee</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Chaiworapongsa</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Espinoza</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Schoen</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Falkensammer</surname>
              <given-names>P</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B9">
        <mixed-citation>9. Devore GR, Falkensammer    P, Sklansky MS, Platt LD. Spatio-temporal image correlation (STIC): new technology    for evaluation of the fetal heart. Ultrasound Obstet Gynecol. 2003;22(4):380-7.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Spatio-temporal image correlation (STIC): new technology for evaluation of the fetal heart</article-title>
          <source>Ultrasound Obstet Gynecol</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>380</fpage>
          <lpage>7</lpage>
          <issue>4</issue>
          <volume>22</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Devore</surname>
              <given-names>GR</given-names>
            </name>
            <name>
              <surname>Falkensammer</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Sklansky</surname>
              <given-names>MS</given-names>
            </name>
            <name>
              <surname>Platt</surname>
              <given-names>LD</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B10">
        <mixed-citation>10. Macklon NS,    Hop WC, Wladimiroff JW. Fetal cardiac function and septal thickness in diabetic    pregnancy: a controlled observational and reproducibility study. Br J Obstet    Gynaecol. 1998;5(6):661-6.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Fetal cardiac function and septal thickness in diabetic pregnancy: a controlled observational and reproducibility study</article-title>
          <source>Br J Obstet Gynaecol</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>661</fpage>
          <lpage>6</lpage>
          <issue>6</issue>
          <volume>5</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Macklon</surname>
              <given-names>NS</given-names>
            </name>
            <name>
              <surname>Hop</surname>
              <given-names>WC</given-names>
            </name>
            <name>
              <surname>Wladimiroff</surname>
              <given-names>JW</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B11">
        <mixed-citation>11. Bethune M,    Bell R. Evaluation of the measurement of the fetal fat layer, interventricular    septum and abdominal circumference percentile in the prediction of macrosomia    in pregnancies affected by gestational diabetes. Ultrasound Obstet Gynecol.    2003;22(6):586-90.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Evaluation of the measurement of the fetal fat layer, interventricular septum and abdominal circumference percentile in the prediction of macrosomia in pregnancies affected by gestational diabetes</article-title>
          <source>Ultrasound Obstet Gynecol</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>586</fpage>
          <lpage>90</lpage>
          <issue>6</issue>
          <volume>22</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Bethune</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Bell</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B12">
        <mixed-citation>12. Moore KL. Anatomia    orientada para a cl&#237;nica. 2&#350; ed. Rio de Janeiro: Guanabara Koogan; 1990.</mixed-citation>
        <element-citation publication-type="book">
          <source>Anatomia orientada para a cl&#237;nica</source>
          <date>
            <year>1990</year>
          </date>
          <person-group person-group-type="author">
            <name>
              <surname>Moore</surname>
              <given-names>KL</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B13">
        <mixed-citation>13. Paladini D.    Standardization of on-screen fetal heart orientation prior to storage of spatio-temporal    image correlation (STIC) volume datasets. Ultrasound Obstet Gynecol. 2007;29(6):605-11.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Standardization of on-screen fetal heart orientation prior to storage of spatio-temporal image correlation (STIC) volume datasets</article-title>
          <source>Ultrasound Obstet Gynecol</source>
          <date>
            <year>2007</year>
          </date>
          <fpage>605</fpage>
          <lpage>11</lpage>
          <issue>6</issue>
          <volume>29</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Paladini</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B14">
        <mixed-citation>14. Hsieh FY, Bloch    DA, Larsen MD. A simple method of sample size calculation for linear and logistic    regression. Stat Med. 1998;17(14):1623-34.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>A simple method of sample size calculation for linear and logistic regression</article-title>
          <source>Stat Med</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>1623</fpage>
          <lpage>34</lpage>
          <issue>14</issue>
          <volume>17</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Hsieh</surname>
              <given-names>FY</given-names>
            </name>
            <name>
              <surname>Bloch</surname>
              <given-names>DA</given-names>
            </name>
            <name>
              <surname>Larsen</surname>
              <given-names>MD</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B15">
        <mixed-citation>15. Altman DG.    Construction of age-related reference centiles using absolute residuals. Stat    Med. 1993;12(10):917-24.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Construction of age-related reference centiles using absolute residuals</article-title>
          <source>Stat Med</source>
          <date>
            <year>1993</year>
          </date>
          <fpage>917</fpage>
          <lpage>24</lpage>
          <issue>10</issue>
          <volume>12</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Altman</surname>
              <given-names>DG</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B16">
        <mixed-citation>16. Bland JM, Altman    DG. Statistical methods for assessing agreement between two methods of clinical    measurement. Lancet. 1986;1(8476):307-10.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Statistical methods for assessing agreement between two methods of clinical measurement</article-title>
          <source>Lancet</source>
          <date>
            <year>1986</year>
          </date>
          <fpage>307</fpage>
          <lpage>10</lpage>
          <issue>8476</issue>
          <volume>1</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Bland</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Altman</surname>
              <given-names>DG</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B17">
        <mixed-citation>17. Vin&#227;ls    F, Poblete P, Giuliano A. Spatio-temporal image correlation (STIC): a new tool    for the prenatal screening of congenital heart defects. Ultrasound Obstet Gynecol.    2003;22(4):388-94.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Spatio-temporal image correlation (STIC): a new tool for the prenatal screening of congenital heart defects</article-title>
          <source>Ultrasound Obstet Gynecol</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>388</fpage>
          <lpage>94</lpage>
          <issue>4</issue>
          <volume>22</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Vin&#227;ls</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Poblete</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Giuliano</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B18">
        <mixed-citation>18. Paladini D,    Sglavo G, Greco E, Nappi C. Cardiac screening by STIC: can sonologists performing    the 20-week anomaly can pick up outflow tract abnormalities by scrolling the    A-plane of STIC volumes? Ultrasound Obstet Gynecol. 2008;32(7):865-70.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Cardiac screening by STIC: can sonologists performing the 20-week anomaly can pick up outflow tract abnormalities by scrolling the A-plane of STIC volumes?</article-title>
          <source>Ultrasound Obstet Gynecol</source>
          <date>
            <year>2008</year>
          </date>
          <fpage>865</fpage>
          <lpage>70</lpage>
          <issue>7</issue>
          <volume>32</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Paladini</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Sglavo</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Greco</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Nappi</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B19">
        <mixed-citation>19. Yagel S, Benachi    A, Bonnet D, Dumez Y, Hochner-Celnikier D, Cohen SM, et al. Rendering in fetal    cardiac scanning: the intracardiac septa and the coronal atrioventricular valve    planes. Ultrasound Obstet Gynecol. 2006; 28(3):266-74.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Rendering in fetal cardiac scanning: the intracardiac septa and the coronal atrioventricular valve planes</article-title>
          <source>Ultrasound Obstet Gynecol</source>
          <date>
            <year>2006</year>
          </date>
          <fpage>266</fpage>
          <lpage>74</lpage>
          <issue>3</issue>
          <volume>28</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Yagel</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Benachi</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Bonnet</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Dumez</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Hochner-Celnikier</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Cohen</surname>
              <given-names>SM</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B20">
        <mixed-citation>20. Paladini D,    Volpe P, Sglavo G, Russo MG, De Robertis V, Penner I, et al. Partial atrioventricular    septal defect in the fetus: diagnostic features and associations in a multicenter    series of 30 cases. Ultrasound Obstet Gynecol. 2009;34(3):268-73.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Partial atrioventricular septal defect in the fetus: diagnostic features and associations in a multicenter series of 30 cases</article-title>
          <source>Ultrasound Obstet Gynecol</source>
          <date>
            <year>2009</year>
          </date>
          <fpage>268</fpage>
          <lpage>73</lpage>
          <issue>3</issue>
          <volume>34</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Paladini</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Volpe</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Sglavo</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Russo</surname>
              <given-names>MG</given-names>
            </name>
            <name>
              <surname>De Robertis</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Penner</surname>
              <given-names>I</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B21">
        <mixed-citation>21. Abu-Sulaiman    RM, Subaih B. Congenital heart disease in infants of diabetic mothers: echocardiograph    study. Pediatr Cardiol. 2004;25(2):137-40.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Congenital heart disease in infants of diabetic mothers: echocardiograph study</article-title>
          <source>Pediatr Cardiol</source>
          <date>
            <year>2004</year>
          </date>
          <fpage>137</fpage>
          <lpage>40</lpage>
          <issue>2</issue>
          <volume>25</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Abu-Sulaiman</surname>
              <given-names>RM</given-names>
            </name>
            <name>
              <surname>Subaih</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B22">
        <mixed-citation>22. Gutgesell HP,    Speer ME, Rosenberg HS. Characterization of the cardiomyopathy in infants of    diabetic mothers. Circulation. 1980;61(2):441-50.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Characterization of the cardiomyopathy in infants of diabetic mothers</article-title>
          <source>Circulation</source>
          <date>
            <year>1980</year>
          </date>
          <fpage>441</fpage>
          <lpage>50</lpage>
          <issue>2</issue>
          <volume>61</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Gutgesell</surname>
              <given-names>HP</given-names>
            </name>
            <name>
              <surname>Speer</surname>
              <given-names>ME</given-names>
            </name>
            <name>
              <surname>Rosenberg</surname>
              <given-names>HS</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B23">
        <mixed-citation>23. Reller MD,    Kaplan S. Hypertrophic cardiomyopathy in infants of diabetic mothers: an update.    Am J Perinatol. 1988;5(4):353-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Hypertrophic cardiomyopathy in infants of diabetic mothers: an update</article-title>
          <source>Am J Perinatol</source>
          <date>
            <year>1988</year>
          </date>
          <fpage>353</fpage>
          <lpage>8</lpage>
          <issue>4</issue>
          <volume>5</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Reller</surname>
              <given-names>MD</given-names>
            </name>
            <name>
              <surname>Kaplan</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B24">
        <mixed-citation>24. Wong ML, Wong    WH, Cheung YF. Fetal myocardial performance in pregnancies complicated by gestational    impaired glucose tolerance. Ultrasound Obstet Gynecol. 2007;29(4):395-400.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Fetal myocardial performance in pregnancies complicated by gestational impaired glucose tolerance</article-title>
          <source>Ultrasound Obstet Gynecol</source>
          <date>
            <year>2007</year>
          </date>
          <fpage>395</fpage>
          <lpage>400</lpage>
          <issue>4</issue>
          <volume>29</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Wong</surname>
              <given-names>ML</given-names>
            </name>
            <name>
              <surname>Wong</surname>
              <given-names>WH</given-names>
            </name>
            <name>
              <surname>Cheung</surname>
              <given-names>YF</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="TRes" xml:lang="es">
    <front-stub>
      <article-categories/>
      <title-group>
        <article-title xml:lang="es">Curva de referencia del &#225;rea del septo interventricular fetal por el m&#233;todo STIC: estudio preliminar</article-title>
      </title-group>
      <abstract xml:lang="es">
        <p>FUNDAMENTO: La detecci&#243;n precoz de alteraciones septales, tales como la hipertrofia septal com&#250;nmente presente en fetos de madres diab&#233;ticas, contribuir&#237;a a la reducci&#243;n de las altas tasas de mortalidad infantil. OBJETIVO: Determinar intervalos de referencia para el &#225;rea del septo interventricular fetal por medio de la ultrasonograf&#237;a tridimensional (US3D) utilizando el m&#233;todo STIC (Spatio-Temporal Image Correlation). M&#201;TODOS: Se realiz&#243; un estudio de corte transversal con 69 gestantes normales entre la 18&#170; y 33&#170; semanas de gestaci&#243;n. Se utiliz&#243; como referencia el plano de cuatro c&#225;maras con la ROI (Regi&#243;n de Inter&#233;s) posicionada a partir de los ventr&#237;culos, siendo el &#225;rea del septo delimitada de modo manual. Para evaluar la correlaci&#243;n del &#225;rea del septo interventricular con la edad gestacional (EG), se construyeron diagramas de dispersi&#243;n y se calcul&#243; el coeficiente de correlaci&#243;n de Pearson (r), siendo el ajuste realizado por el coeficiente de determinaci&#243;n (R&#178;). Fueron calculadas medias, medianas, desviaciones-est&#225;ndar (de), valores m&#225;ximo y m&#237;nimo. Para el c&#225;lculo de la reproductibilidad intraobservador, se utiliz&#243; el coeficiente de correlaci&#243;n intraclase (CCI). Se obtuvo la medida del espesor del septo interventricular y la misma fue correlacionada con la EG y el &#225;rea septal obtenida por el modo renderizado en 52 pacientes utilizando el CCI. RESULTADOS: El &#225;rea del septo interventricular fue altamente correlacionada con la edad gestacional (r = 0,81), y la media aument&#243; de 0,47 cm&#178; en la 18&#170; a 2,42 cm&#178; en la 33&#170; semana de gestaci&#243;n. La reproductibilidad intraobservador fue excelente con CCI = 0,994. No se observ&#243; correlaci&#243;n significativa entre la medida del septo interventricular y la EG (R&#178; = 0,200), as&#237; como no hubo correlaci&#243;n con el &#225;rea del septo obtenida por el modo renderizado con CCI = 0,150. CONCLUSI&#211;N: Intervalos de referencia para el &#225;rea del septo interventricular entre la 18&#170; y 33&#170; semanas de gestaci&#243;n fueron determinados y se mostraron altamente reproducibles. (Arq Bras Cardiol 2011;96(5):386-392)</p>
      </abstract>
      <kwd-group xml:lang="es">
        <kwd>Gravidez</kwd>
        <kwd>coraz&#243;n fetal</kwd>
        <kwd>septo interventricular</kwd>
        <kwd>valores de referencia</kwd>
        <kwd>imagen tridimensional</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>ART&#205;CULO ORIGINAL</bold>
      </p>
      <fig id="topo-body2"/>
      <p>Curva de referencia del &#225;rea del septo interventricular fetal por el m&#233;todo STIC: estudio preliminar</p>
      <p>
        <bold>Liliam Cristine Rolo; Luciano Marcondes Machado Nardozza; Edward Araujo J&#250;nior; Christiane Simioni; Marina Maccagnano Zamith; Antonio Fernandes Moron</bold>
      </p>
      <p>Departamento de Obstetr&#237;cia - Universidade Federal de S&#227;o Paulo, S&#227;o Paulo, SP - Brasil</p>
      <p>Correspondencia</p>
      <p>
        <bold>RESUMEN</bold>
      </p>
      <p><bold>FUNDAMENTO:</bold> La detecci&#243;n precoz de alteraciones septales, tales como la hipertrofia septal com&#250;nmente presente en fetos de madres diab&#233;ticas, contribuir&#237;a a la reducci&#243;n de las altas tasas de mortalidad infantil.</p>
      <p><bold>OBJETIVO:</bold> Determinar intervalos de referencia para el &#225;rea del septo interventricular fetal por medio de la ultrasonograf&#237;a tridimensional (US3D) utilizando el m&#233;todo STIC (<italic>Spatio-Temporal Image Correlation</italic>).</p>
      <p><bold>M&#201;TODOS:</bold> Se realiz&#243; un estudio de corte transversal con 69 gestantes normales entre la 18&#170; y 33&#170; semanas de gestaci&#243;n. Se utiliz&#243; como referencia el plano de cuatro c&#225;maras con la ROI (Regi&#243;n de Inter&#233;s) posicionada a partir de los ventr&#237;culos, siendo el &#225;rea del septo delimitada de modo manual. Para evaluar la correlaci&#243;n del &#225;rea del septo interventricular con la edad gestacional (EG), se construyeron diagramas de dispersi&#243;n y se calcul&#243; el coeficiente de correlaci&#243;n de Pearson (r), siendo el ajuste realizado por el coeficiente de determinaci&#243;n (R<sup>2</sup>). Fueron calculadas medias, medianas, desviaciones-est&#225;ndar (de), valores m&#225;ximo y m&#237;nimo. Para el c&#225;lculo de la reproductibilidad intraobservador, se utiliz&#243; el coeficiente de correlaci&#243;n intraclase (CCI). Se obtuvo la medida del espesor del septo interventricular y la misma fue correlacionada con la EG y el &#225;rea septal obtenida por el modo renderizado en 52 pacientes utilizando el CCI.</p>
      <p><bold>RESULTADOS:</bold> El &#225;rea del septo interventricular fue altamente correlacionada con la edad gestacional (r = 0,81), y la media aument&#243; de 0,47 cm<sup>2</sup> en la 18&#170; a 2,42 cm<sup>2</sup> en la 33&#170; semana de gestaci&#243;n. La reproductibilidad intraobservador fue excelente con CCI = 0,994. No se observ&#243; correlaci&#243;n significativa entre la medida del septo interventricular y la EG (R&#178; = 0,200), as&#237; como no hubo correlaci&#243;n con el &#225;rea del septo obtenida por el modo renderizado con CCI = 0,150.</p>
      <p><bold>CONCLUSI&#211;N:</bold> Intervalos de referencia para el &#225;rea del septo interventricular entre la 18&#170; y 33&#170; semanas de gestaci&#243;n fueron determinados y se mostraron altamente reproducibles. (Arq Bras Cardiol 2011;96(5):386-392)</p>
      <p><bold>Palabras clave:</bold> Gravidez, coraz&#243;n fetal, septo interventricular, valores de referencia, imagen tridimensional.</p>
      <p>
        <bold>Introducci&#243;n</bold>
      </p>
      <p>El aumento progresivo de la demanda de ox&#237;geno en raz&#243;n del r&#225;pido crecimiento del embri&#243;n durante las fases iniciales de la embriog&#233;nesis determina la precoz formaci&#243;n card&#237;aca alrededor del 22&#186;-23&#186; d&#237;a de gestaci&#243;n<sup>1</sup>. Progresivamente, el coraz&#243;n primitivo fetal sufre una serie de procesos de remodelado capaces de modificar su anatom&#237;a, hasta alcanzar la forma funcional que conocemos<sup>1</sup>.</p>
      <p>El coraz&#243;n, ya compuesto de sus cuatro c&#225;maras (atrios y ventr&#237;culos), presenta en el interior de sus ventr&#237;culos el septo interventricular (IV) divisor, formado a partir de la fusi&#243;n de las paredes mediales: la parte muscular del septo IV. Dentro de los ventr&#237;culos, con la cavitaci&#243;n de los mismos, los haces musculares ser&#225;n formados y estos originan los m&#250;sculos papilares y las cuerdas tend&#237;neas<sup>1</sup>, con funci&#243;n de competencia valvular, impidiendo el prolapso de las c&#250;spides durante la s&#237;stole card&#237;aca y el reflujo sangu&#237;neo<sup>2</sup>.</p>
      <p>En 50% de los casos, las malformaciones card&#237;acas son consideradas defectos mayores, factores determinantes de la elevaci&#243;n de la tasa de la mortalidad infantil precoz y tardia<sup>3,4</sup>, evidenciando la necesidad del rastreo y diagn&#243;stico precoz de tales cardiopat&#237;as. A pesar de la amplia aplicaci&#243;n de la ultrasonograf&#237;a convencional en el rastreo de cardiopat&#237;as cong&#233;nitas, la detecci&#243;n prenatal aun presenta lagunas diagn&#243;sticas, lo que impulsa el desarrollo de nuevas t&#233;cnicas de adquisici&#243;n de imagen para un mejor rastreo card&#237;aco durante la rutina del prenatal<sup>5-7</sup>.</p>
      <p>En las &#250;ltimas d&#233;cadas, con el desarrollo de la ultrasonograf&#237;a tridimensional (US3D) y de la tecnolog&#237;a del<italic> Spatio-Temporal Image Correlation </italic>(STIC), surgi&#243; una nueva forma de an&#225;lisis card&#237;aco prenatal. Tal t&#233;cnica permite la obtenci&#243;n del volumen card&#237;aco y su almacenamiento para posterior reconstrucci&#243;n y an&#225;lisis de su anatom&#237;a, presentando la imagen en el modo multiplanar y de superficie (renderizada), identific&#225;ndose las c&#225;maras card&#237;acas, las v&#225;lvulas atrioventriculares y semilunares, adem&#225;s del posicionamiento de los vasos y sus correlaciones, pudi&#233;ndose tambi&#233;n controlar el movimiento card&#237;aco por el uso de la t&#233;cnica del <italic>cineloop</italic><sup>7-9</sup>.</p>
      <p>A pesar de los inn&#250;meros trabajos desarrollados con la t&#233;cnica de STIC, no se encuentra en la literatura su aplicaci&#243;n en la evaluaci&#243;n de la medida del &#225;rea del septo interventricular en corazones de fetos normales y/o card&#237;acos. Esa medida ser&#237;a una forma de analizar directamente los defectos septales, que son los defectos card&#237;acos cong&#233;nitos m&#225;s com&#250;nmente encontrados, justificando cerca de 30% de las enfermedades card&#237;acas, en especial los defectos membran&#225;ceos<sup>1</sup>, adem&#225;s de analizar indirectamente las dem&#225;s malformaciones card&#237;acas (como las estenosis valvulares con consecuentes hipertrofias ventriculares entre otras). Adem&#225;s de eso, la medida del &#225;rea valvular posibilitar&#225; la detecci&#243;n precoz de la hipertrofia septal en los fetos de gestantes diab&#233;ticas, rastreando fetos con mayor probabilidad de desarrollo de macrosom&#237;a y cardiomiopat&#237;a<sup>10,11</sup>.</p>
      <p>Este estudio tiene por objetivo determinar valores de referencia para el &#225;rea del septo interventricular de fetos normales entre la 18&#170; y la 33&#170; semanas de gestaci&#243;n por medio de la US3D utilizando el m&#233;todo STIC.</p>
      <p>
        <bold>M&#233;todos</bold>
      </p>
      <p>Se realiz&#243; un estudio del tipo corte transversal, entre diciembre de 2009 y mayo de 2010, con 69 gestantes entre la 18&#170; y la 33&#170; semanas completas de gestaci&#243;n. Este estudio fue aprobado por el Comit&#233; de &#201;tica en Investigaci&#243;n de la Universidad Federal de S&#227;o Paulo (Unifesp) bajo el n<sup>0</sup> 0135/10, y las pacientes que concordaron en la participaci&#243;n voluntaria firmaron T&#233;rmino de Consentimiento Libre y Aclarado.</p>
      <p>Todas las pacientes fueron seleccionadas en el sector de prenatal de bajo riesgo del Departamento de Obstetricia de la Unifesp, siendo oriundas del Sistema &#218;nico de Salud del municipio y de la regi&#243;n metropolitana de la ciudad de S&#227;o Paulo. Los criterios de inclusi&#243;n fueron los siguientes: gestaci&#243;n &#250;nica con embri&#243;n vivo y edad gestacional determinada por la fecha de la &#250;ltima menstruaci&#243;n (FUM) y confirmada por ultrasonograf&#237;a realizada hasta la 10&#170; semana utilizando como par&#225;metro el Largo Cabeza-Nalga (LCN). Los criterios de exclusi&#243;n fueron: oligoamnio [&#205;ndice de L&#237;quido Amni&#243;tico (ILA) abajo del percentil 5 para la edad gestacional, seg&#250;n tabla propuesta por Moore y Cayle<sup>12</sup>; feto posicionado con el dorso anterior (entre 11 y 1h); fetos con peso estimado abajo y/o encima de dos desviaciones-est&#225;ndar de la media, de acuerdo con la tabla propuesta de Hadlock; gestantes portadoras de enfermedades cr&#243;nicas que pudiesen afectar el crecimiento y desarrollo fetal, tales como hipertensi&#243;n arterial, diabetes mellitus, colagenosis, entre otras; atenuaci&#243;n intensa del haz sonoro por condiciones tales como obesidad materna y cicatrices abdominales; malformaci&#243;n fetal diagnosticada en la ultrasonograf&#237;a morfol&#243;gica de 1&#186; y 2&#186; trimestres; pacientes tabaquistas y/o usuarias de drogas il&#237;citas. Todas las gestantes fueron sometidas la ecocardiograf&#237;a fetal realizada entre 20 y 24 semanas de gestaci&#243;n.</p>
      <p>Todos los ex&#225;menes fueron realizados en el Sector de Cardiolog&#237;a Fetal del Departamento de Obstetricia de la Unifesp, siendo realizados por apenas un examinador (LCR) con experiencia de tres a&#241;os en US3D en obstetricia. Todos los ex&#225;menes fueron realizados en un aparato de la marca Voluson 730 Expert (General Eletric Medical Systems, Kretztechnic, Zipf, Austria) equipado con un transductor convexo volum&#233;trico (RAB4-8P). Los an&#225;lisis <italic>off-line</italic> para la medida de las &#225;reas del septo interventricular fueron realizadas por el mismo examinador utilizando el <italic>software</italic> 4D <italic>View</italic> versi&#243;n 9.0 (GE, Medical Systems Kretztechnic, GmbH &amp; Co OHG).</p>
      <p>Los vol&#250;menes card&#237;acos fueron recogidos en el corte de las 4 c&#225;maras card&#237;acas con el dorso fetal, si fuese posible, en la posici&#243;n de 6 horas, utiliz&#225;ndose un &#225;ngulo de abertura entre 20 y 40<sup>0</sup> y un tiempo de adquisici&#243;n de entre 10 y 15 segundos. Despu&#233;s del barrido tridimensional, la imagen fue presentada en la tela del aparato en la forma de tres planos ortogonales: axial (A), sagital (B) y coronal (C). Antes de iniciar las evaluaciones, fue utilizada la estandarizaci&#243;n propuesta por Paladini<sup>13</sup> para la orientaci&#243;n de vol&#250;menes obtenidos por el STIC, o sea, para fetos en presentaci&#243;n cef&#225;lica, el lado izquierdo del coraz&#243;n coincide con el lado izquierdo de la tela, mientras para los fetos p&#233;lvicos, el lado izquierdo del coraz&#243;n coincide con el lado derecho de la tela; debi&#233;ndose rotar el plano A 180<sup>0</sup> alrededor del eje "Y". </p>
      <p>El plano de las cuatro c&#225;maras card&#237;acas (A) fue seleccionado como referencial, siendo este rotado alrededor del eje "Z", de forma que el &#225;pice card&#237;aco se colocase en 6 horas; enseguida, fue activada la tecla RENDER, con punto de referencia de la caja dispuesta en el tercio medio del septo interventricular. Tres planos virtuales para evaluaci&#243;n del septo interventricular fueron utilizados. Dos planos fueron determinados por el posicionamiento de la l&#237;nea verde (activa) de la caja de renderizaci&#243;n paralelo al borde externo del septo interventricular, con el punto medio mantenido en su tercio medio. Se utiliz&#243; la opci&#243;n seis de la ROI <italic>selection</italic>, delimit&#225;ndose la regi&#243;n del septo; por convenci&#243;n, se opt&#243; por su visibilizaci&#243;n a trav&#233;s del lado del ventr&#237;culo izquierdo. La imagen renderizada fue magnificada y entonces la tecla MEASURE fue accionada y la opci&#243;n TRACE AREA fue seleccionada para delimitar manualmente el &#225;rea septal en cm&#178;. La medida del &#225;rea septal fue realizada durante la fase inicial de la di&#225;stole ventricular, momento en que el septo se encontraba menos contra&#237;do (<xref ref-type="fig" rid="esa06f1-body2">Fig. 1</xref>). La medida bidimensional del espesor septal tambi&#233;n fue obtenida en el plano de cuatro c&#225;maras en mm. (<xref ref-type="fig" rid="esa06f2-body2">Fig. 2</xref>).</p>
      <p content-type="asset">
        <fig id="esa06f1-body2">
          <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf01-es.jpg"/></fig>
      </p>
      <p content-type="asset">
        <fig id="esa06f2-body2">
          <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf02-es.jpg"/></fig>
      </p>
      <p>Los datos fueron almacenados en planilla del programa Excel (Microsoft, Redmond, WA, USA) y analizados por medio de un programa estad&#237;stico <italic>Statistical Package for the Social Sciences</italic> (SPSS) for Windows versi&#243;n 15.0 (SPSS Inc., Chicago, IL, USA). Fueron calculadas medias, medianas, desviaciones-est&#225;ndar (de), valores m&#225;ximo y m&#237;nimo para cada intervalo gestacional evaluado, as&#237; como los percentiles 5, 25, 50, 75 y 95. Para evaluar la correlaci&#243;n entre las &#225;reas del septo interventricular con la edad gestacional (EG), fueron determinados diagramas de dispersi&#243;n obteni&#233;ndose &#237;ndice de correlaci&#243;n de Pearson (r), siendo el ajuste de la ecuaci&#243;n determinado por el coeficiente de determinaci&#243;n (R<sup>2</sup>). Para la construcci&#243;n de intervalos de referencia de las &#225;reas del septo interventricular en funci&#243;n de la edad gestacional, se sigui&#243; el modelo de regresi&#243;n lineal simple<sup>14</sup>, utilizando el m&#233;todo de Altman<sup>15</sup> con nivel de significaci&#243;n de p &lt; 0,05. Para evaluar la medida del espesor septal en funci&#243;n de la edad gestacional se utiliz&#243; tambi&#233;n la regresi&#243;n lineal. Para evaluar la correlaci&#243;n entre la medida del espesor bidimensional del septo interventricular y su &#225;rea, se utiliz&#243; el coeficiente de correlaci&#243;n intraclase (CCI). Para el c&#225;lculo de la reproductibilidad intraobservador, el mismo examinador (LCR) realiz&#243; una segunda medida del &#225;rea septal de 40 fetos, medidas esas blindadas de los resultados de la primera. Para esto, tambi&#233;n se utiliz&#243; el CCI y el gr&#225;fico de Bland-Altman<sup>16</sup>. Los gr&#225;ficos de Bland-Altman plotean las medias dos medidas, realizadas por un mismo examinador, contra la diferencia de sus medias con intervalo de 95% de confianza de 1,96 de la media. En todos los an&#225;lisis se utiliz&#243; nivel de significaci&#243;n de 0,05.</p>
      <p>
        <bold>Resultados</bold>
      </p>
      <p>Fueron evaluadas 69 gestantes portando fetos normales entre la 18&#170; y la 33&#170; semanas completas de gestaci&#243;n, y todas llenaron los criterios de inclusi&#243;n y fueron ubicadas en el an&#225;lisis estad&#237;stico final. La edad materna en media fue de 29,8 a&#241;os con de &#177; 5,1, con media de 1,4 gestaci&#243;n (de &#177; 0,5) y paridad media de 0,3 parto (de &#177; 0,5).</p>
      <p>El &#225;rea media del &#225;rea septal fue de 0,47 &#177; 0,10 cm<sup>2 </sup>(variando de 0,36 - 0,59 cm<sup>2</sup>) en la 18&#170; semana a 2,42 &#177; 1,13 cm<sup>2</sup> (variando de 1,26 - 3,92 cm<sup>2</sup>) en la 33&#170; semana de gestaci&#243;n. La <xref ref-type="table" rid="esa06t1-body2">tabla 1</xref> muestra medias, medianas, desviaciones-est&#225;ndar y valores m&#237;nimos y m&#225;ximos del &#225;rea del septo interventricular, mientras que la <xref ref-type="table" rid="esa06t2-body2">tabla 2</xref> muestra los percentiles 5, 25, 50, 75 y 95 en cada intervalo gestacional evaluado.</p>
      <p content-type="asset">
        <table-wrap id="esa06t1-body2">
          <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gt01-es.jpg"/></table-wrap>
      </p>
      <p content-type="asset">
        <table-wrap id="esa06t2-body2">
          <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gt02-es.jpg"/></table-wrap>
      </p>
      <p>El &#225;rea septal present&#243; fuerte correlaci&#243;n con la edad gestacional (r = 0,81). Fueron realizados modelos de regresi&#243;n polinomial, siendo el mejor ajuste con la ecuaci&#243;n exponencial: &#225;rea del septo interventricular = exp (0,125 x IG + 0,043), con R<sup>2</sup>=0,65 (<xref ref-type="fig" rid="esa06f3-body2">Fig. 3</xref>).</p>
      <p content-type="asset">
        <fig id="esa06f3-body2">
          <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf03-es.jpg"/></fig>
      </p>
      <p>En 52 pacientes, la medida del espesor septal fue obtenida en el modo bidimensional, pero no present&#243; correlaci&#243;n significativa con la edad gestacional (R&#178; = 0,20), mostrando un est&#225;ndar pr&#225;cticamente lineal entre la 18&#170; y la 33&#170; semanas completas de gestaci&#243;n (<xref ref-type="fig" rid="esa06f4-body2">Fig. 4</xref>). Adem&#225;s de eso, no hubo correlaci&#243;n estad&#237;sticamente significativa entre la medida del espesor y del &#225;rea septal en el intervalo gestacional estudiado con CCI = 0,150 [95% IC -0,480; 0,512], con p &lt; 0,005.</p>
      <p content-type="asset">
        <fig id="esa06f4-body2">
          <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf04-es.jpg"/></fig>
      </p>
      <p>Se observ&#243; una excelente reproductibilidad intraobservador para la medida del &#225;rea del septo interventricular, con CCI= 0,994 (IC 95% 0,988 - 0,997). El gr&#225;fico de Bland-Altman comprob&#243; esa buena reproductibilidad con media de la diferencia entre las medidas de 0,01 cm<sup>2</sup> (de &#177; 0,06 cm<sup>2</sup> y IC 95% &#177; 0,12 cm<sup>2</sup>) (<xref ref-type="fig" rid="esa06f5-body2">Fig. 5</xref>).</p>
      <p content-type="asset">
        <fig id="esa06f5-body2">
          <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf05-es.jpg"/></fig>
      </p>
      <p>
        <bold>Discusi&#243;n</bold>
      </p>
      <p>La tecnolog&#237;a STIC ha estado disponible en algunos aparatos de US3D a mediados de la d&#233;cada de 2010. STIC consiste en la adquisici&#243;n del volumen del coraz&#243;n fetal con sus conexiones vasculares, permitiendo su evaluaci&#243;n en los modos multiplanar o renderizado en la forma de una secuencia "cineloop" de un ciclo card&#237;aco completo. Para la adquisici&#243;n del volumen, se debe seleccionar una regi&#243;n de inter&#233;s (ROI), que determina la altura y ancho del volumen, que englobe todo el coraz&#243;n con sus conexiones vasculares. Siempre que sea posible, la adquisici&#243;n debe ser realizada con el feto en dorso posterior (6 horas) y en la ausencia de movimientos respiratorios maternos. El &#225;ngulo de adquisici&#243;n, que determina la profundidad del volumen, var&#237;a de acuerdo con la edad gestacional, y &#225;ngulos entre 20 y 25<sup>0</sup> son suficientes en fetos en el segundo trimestre. El tiempo de adquisici&#243;n es determinado por el operador, variando de 7,5 a 15 segundos, y corresponde a la velocidad con que el transductor barre la ROI. Al volumen en escala de grises, se puede asociar el modo Doppler color, adem&#225;s de post procesamientos como el "inversion mode" y el "B-flow imaging"<sup>8,17</sup>. La ventaja del STIC en relaci&#243;n a la ecocardiograf&#237;a bidimensional es la de ser un m&#233;todo menos dependiente del operador, posibilitando la identificaci&#243;n de anormalidades en las v&#237;as de salida del coraz&#243;n fetal por examinadores con poca a intermedia experiencia<sup>18</sup>. </p>
      <p>En relaci&#243;n a la renderizaci&#243;n de estructuras card&#237;acas, Yagel et al<sup>19</sup> evaluaron 136 gestantes, siendo 35 portando fetos con anomal&#237;as card&#237;acas, utilizando la renderizaci&#243;n para obtener planos para evaluaci&#243;n de los septos interatrial y interventricular, &#225;nulo de las v&#225;lvulas atrioventriculares y alineamiento de los grandes vasos. En 13 fetos con anomal&#237;as card&#237;acas, el plano del septo interventricular mejor&#243; la evaluaci&#243;n del defecto septal, y en 4 el plano del septo interatrial contribuy&#243; para evaluaci&#243;n del foramen oval. En 5 casos, el plano del &#225;nulo de las v&#225;lvulas atrioventriculares inmediatamente distales a las v&#225;lvulas semilunares (coronal AV) mejor&#243; la evaluaci&#243;n del alineamiento de los grandes vasos en relaci&#243;n al &#225;nulo de las v&#225;lvulas atrioventriculares, y en 3 la evaluaci&#243;n de las v&#225;lvulas semilunares, con o sin mal alineamiento de los grandes vasos. Recientemente, Paladini et al<sup>20</sup> evaluaron una serie de 30 casos de defectos parciales del septo atrioventricular fetal utilizando la ecocardiograf&#237;a, y en 14 de esos casos se asoci&#243; el STIC. En todos los casos los marcadores ecocardiogr&#225;ficos para esa anomal&#237;a fueron: defecto del septo atrial ostium primum y p&#233;rdida de la apariencia normal de las v&#225;lvulas atrioventriculares. </p>
      <p>La medida del &#225;rea del septo interventricular es de particular importancia en fetos de riesgo para miocardiopat&#237;as hipertr&#243;ficas, como los hijos de madres diab&#233;ticas, en los cuales hay importante engrosamiento del septo interventricular, pudiendo causar obstrucciones en el tracto de salida del ventr&#237;culo izquierdo<sup>21</sup>. La gravedad de los s&#237;ntomas de insuficiencia respiratoria e insuficiencia card&#237;aca congestiva se correlacionan con la severidad de la miocardiopat&#237;a hipertr&#243;fica<sup>22,23</sup>. Tradicionalmente la medida del espesor del septo interventricular fetal ha sido realizada por la ecocardiograf&#237;a bidimensional utilizando el modo M<sup>10,11,24</sup>; con todo, tal medida presenta imprecisiones, pues el septo interventricular no es una estructura uniforme.</p>
      <p> En este estudio, se utiliz&#243; la t&#233;cnica STIC para medida del &#225;rea del septo interventricular, metodolog&#237;a hasta el momento in&#233;dita en la literatura. El &#225;rea del septo se mostr&#243; fuertemente correlacionada con la edad gestacional, adem&#225;s de comprobada reproductibilidad intraobservador. Ya la medida del espesor septal mostr&#243; d&#233;bil correlaci&#243;n con la edad gestacional, mostrando un est&#225;ndar pr&#225;cticamente lineal de la medida entre la 18&#170; y la 33&#170; semanas completas de gestaci&#243;n, sin presentar correlaci&#243;n estad&#237;sticamente significativa con &#225;rea obtenida por el STIC. Tal resultado vuelve el &#225;rea septal un posible par&#225;metro ultrasonogr&#225;fico m&#225;s fidedigno que la medida del espesor del septo interventricular en el diagn&#243;stico de hipertrofia septal.</p>
      <p>En s&#237;ntesis, este estudio determin&#243; valores de referencia para el &#225;rea del septo interventricular fetal que podr&#225;n ser aplicados en fetos de riesgo para hipertrofia septal, como los hijos de madres diab&#233;ticas, favoreciendo la detecci&#243;n precoz de alteraciones funcionales y morfol&#243;gicas card&#237;acas fetales.</p>
      <p>
        <bold>Potencial Conflicto de Intereses</bold>
      </p>
      <p>Declaro no haber conflicto de intereses pertinentes.</p>
      <p>
        <bold>Fuentes de Financiaci&#243;n</bold>
      </p>
      <p>CAPES financi&#243; el presente estudio.</p>
      <p>
        <bold>Vinculaci&#243;n Acad&#233;mica</bold>
      </p>
      <p>Este art&#237;culo forma parte de tesis de Doctorado de Liliam Cristine Rolo, from <italic>Universidade Federal de S&#227;o Paulo</italic>.</p>
      <p>
        <bold>Referencias</bold>
      </p>
    </body>
  </sub-article>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Articles</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Reference curve of the fetal ventricular septum area by the STIC method: preliminary study</article-title>
      </title-group>
      <abstract xml:lang="en">
        <p>BACKGROUND: Early detection of septal changes such as septal hypertrophy commonly present in fetuses of diabetic mothers would help reduce the high rates of infant mortality. OBJECTIVE: Determine reference ranges for the fetal ventricular septal area through three-dimensional ultrasound (US3D) using the STIC method (Spatio-Temporal Image Correlation). METHODS: We conducted a cross-sectional study with 69 pregnant women between the 18th and 33rd weeks of pregnancy. We used as a reference the four-chamber plane with the ROI (Region of Interest) positioned from the ventricles; the septum area were manually marked. To assess the correlation of the interventricular septum area with gestational age (GA), we constructed scatter plots and calculated Pearson's correlation coefficient (r), and the adjustment was performed by the coefficient of determination (R&#178;). We calculated averages, medians, standard deviations (sd), as well as maximum and minimum values. To calculate the intraobserver reproducibility, we used the intraclass correlation coefficient (ICC). The interventricular septum thickness was measured and it was correlated with gestational age and the septal area rendered in 52 patients using the ICC. RESULTS: The interventricular septum area was highly correlated with gestational age (r = 0.81), and the average increased from 0.47 cm&#178; in the 18th week to 2.42 cm&#178; in the 33rd of gestation. The intraobserver reproducibility was excellent with ICC = 0.994. No significant correlation was observed between the interventricular septum measurement and the GA (R&#178; = 0.200), as well as there was no correlation with the septal area rendered with ICC = 0.150. CONCLUSION: Reference intervals for the interventricular septum area between the 18th and the 33rd pregnancy week were determined to be highly reproducible.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>Pregnancy</kwd>
        <kwd>fetal heart</kwd>
        <kwd>ventricular septum</kwd>
        <kwd>reference values</kwd>
        <kwd>imaging, three-dimensional</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>ORIGINAL ARTICLE</bold>
      </p>
      <p>
        <fn id="top-body3">
          <label>
            <bold>Reference curve of the fetal ventricular septum area by the STIC method: preliminary study</bold>
          </label>
          <p>
            <bold>Liliam Cristine Rolo; Luciano Marcondes Machado Nardozza; Edward Araujo J&#250;nior; Christiane Simioni; Marina Maccagnano Zamith; Antonio Fernandes Moron</bold>
          </p>
        </fn>
      </p>
      <p>Departamento de Obstetr&#237;cia - Universidade Federal de S&#227;o Paulo, S&#227;o Paulo, SP - Brazil</p>
      <p>Mailing address</p>
      <p>
        <bold>ABSTRACT</bold>
      </p>
      <p><bold>BACKGROUND: </bold> Early detection of septal changes such as septal hypertrophy commonly present in fetuses of diabetic mothers would help reduce the high rates of infant mortality.</p>
      <p><bold>OBJECTIVE:</bold> Determine reference ranges for the fetal ventricular septal area through three-dimensional ultrasound (US3D) using the STIC method (Spatio-Temporal Image Correlation).</p>
      <p><bold>METHODS:</bold> We conducted a cross-sectional study with 69 pregnant women between the 18<sup>th</sup> and 33<sup>rd</sup> weeks of pregnancy. We used as a reference the four-chamber plane with the ROI (Region of Interest) positioned from the ventricles; the septum area were manually marked. To assess the correlation of the interventricular septum area with gestational age (GA), we constructed scatter plots and calculated Pearson's correlation coefficient (r), and the adjustment was performed by the coefficient of determination (R<sup>2</sup>). We calculated averages, medians, standard deviations (sd), as well as maximum and minimum values. To calculate the intraobserver reproducibility, we used the intraclass correlation coefficient (ICC). The interventricular septum thickness was measured and it was correlated with gestational age and the septal area rendered in 52 patients using the ICC.</p>
      <p><bold>RESULTS:</bold> The interventricular septum area was highly correlated with gestational age (r = 0.81), and the average increased from 0.47 cm<sup>2</sup> in the 18<sup>th</sup> week to 2.42 cm<sup>2</sup> in the 33<sup>rd</sup> of gestation. The intraobserver reproducibility was excellent with ICC = 0.994. No significant correlation was observed between the interventricular septum measurement and the GA (R&#178; = 0.200), as well as there was no correlation with the septal area rendered with ICC = 0.150.</p>
      <p><bold>CONCLUSION:</bold> Reference intervals for the interventricular septum area between the 18<sup>th</sup> and the 33<sup>rd</sup> pregnancy week were determined to be highly reproducible.</p>
      <p><bold>Keywords:</bold> Pregnancy; fetal heart; ventricular septum; reference values; imaging, three-dimensional.</p>
      <p>
        <bold>Introduction</bold>
      </p>
      <p>The progressive increase in oxygen demand due to the rapid growth of the embryo during the early stages of embryogenesis determines the early heart formation around the 22<sup>nd</sup> - 23<sup>th</sup> days of gestation<sup>1</sup>. Progressively, the primitive fetal heart undergoes a series of remodeling processes capable of modifying their anatomy to reach the functional form we know<sup>1</sup>.</p>
      <p>When the heart has its four chambers (atria and ventricles), its ventricles present the divider interventricular septum (IV) formed from the merger of the medial walls: the muscular part of the IV septum. Within the ventricles, with their cavitation, the muscle bundles are formed and these originate the papillary muscles and the chordae tendineae, or heart strings<sup>1</sup>, with the function of valve competence, preventing the prolapse of the cuspid valves during the cardiac systole and blood reflux<sup>2</sup>.</p>
      <p>In 50% of the cases, congenital heart defects are considered major factors determining the high rate of early and late infant mortality<sup>3,4</sup>, highlighting the need for screening and providing early diagnosis of such heart diseases. Despite the wide application of conventional ultrasonography in screening for heart defects, antenatal detection still has some diagnosis gaps, which drives the development of new image acquisition techniques for a better cardiac screening during routine antenatal tests<sup>5-7</sup>.</p>
      <p>In recent decades, with the development of three-dimensional ultrasound (US3D) and the Spatio-Temporal Image Correlation technology (STIC), a new form of prenatal cardiac examination has emerged. This technique allows obtaining cardiac volume and its storage for later reconstruction and analysis of anatomy, presenting the image in the multiplanar and surface mode (rendered), identifying the cardiac chambers, semilunar and atrioventricular valves, and the positioning of vessels and their correlations, and it is also possible to track the cardiac motion by using the cineloop technique<sup>7-9</sup>.</p>
      <p>Despite the number of projects developed with the STIC technique, the literature does not provide its application in assessing the interventricular septum area in hearts of normal fetuses and/or patients with heart disease. This would be a way to directly analyze septal defects, which are the most common congenital heart defects, accounting for about 30% of heart diseases, especially membrane defects<sup>1</sup>, also analyzing indirectly other cardiac malformations (such as valvular stenoses with consequent ventricular hypertrophy, among others). Moreover, the valve area measurement will allow the early detection of septal hypertrophy in fetuses of diabetic pregnant women, by tracking fetuses with greater likelihood of developing macrosomia and cardiomyopathy<sup>10,11</sup>.</p>
      <p>This study aims to determine reference values for the interventricular septum area of normal fetuses between the 18<sup>th</sup> and the 33<sup>rd</sup> pregnancy week through the US3D by using the method STIC.</p>
      <p>
        <bold>Methods</bold>
      </p>
      <p>We conducted a cross-sectional study from December 2009 to May 2010 with 69 pregnant women between the 18<sup>th</sup> and the 33<sup>rd</sup> pregnancy week. This study was approved by the Research Ethics Committee of the Federal University of S&#227;o Paulo (UNIFESP) under number 0135/10, and patients who agreed to participate voluntarily signed a consent form.</p>
      <p>All patients were selected in the low-risk prenatal sector of the Obstetrics Department of Unifesp, these being derived from the Brazilian Public Health System of the city and metropolitan area of S&#227;o Paulo. Inclusion criteria were: singleton pregnancies with live embryo and gestational age determined by the last menstrual period (LMP) confirmed by ultrasound test performed until the 10<sup>th</sup> week, using the crown-rump length (CRL) as a parameter. The exclusion criteria were: oligohydramnios [amniotic fluid index (AFI) below the 5<sup>th</sup> percentile for gestational age, according to the table proposed by Moore and Cayle<sup>12</sup>; fetus in the dorsal anterior position (between 11 and 1am); estimated fetal weight below and/or above two standard deviations from the average, according to the table proposed by Hadlock; pregnant women with chronic illnesses that could affect fetal growth and development, such as hypertension, diabetes mellitus, collagen diseases, among others; intense sound beam attenuation by conditions such such as maternal obesity and abdominal scars; fetal malformations diagnosed at morphology ultrasound of 1<sup>st</sup> and 2<sup>nd</sup> quarters; smokers and/or users of illegal drugs. All pregnant women underwent fetal echocardiography between the 20<sup>th</sup> and 24<sup>th</sup> pregnancy week.</p>
      <p>All examinations were performed in the Sector of Fetal Cardiology of the Department of Obstetrics of Unifesp, these being performed by a single examiner (LCR) with three years' experience in US3D in obstetrics. All examinations were performed on a device of the brand Voluson 730 Expert (General Electric Medical Systems, Kretztechnic, Zipf, Austria) equipped with a volumetric transducer (RAB4-8P). The offline analyses to measure the interventricular septum areas were performed by the same examiner using the software 4D View version 9.0 (GE, Medical Systems Kretztechnic, GmbH &amp; Co OHG).</p>
      <p>Cardiac volumes were collected in the four heart chambers section with the fetal back, if possible, at the 6 o'clock position, using an opening angle between 20&#186; and 40&#186; and an acquisition time between 10 and 15 seconds. After the three-dimensional scanning, the image was displayed on the device screen as three orthogonal planes: axial (A), sagittal (B) and coronal (C). Before starting the examinations, we used the standard proposed by Paladini<sup>13</sup> in order to guide the volumes obtained by the STIC, that is, for fetuses in the cephalic position, the left side of the heart coincides with the left side of the screen, while for pelvic fetuses, the left side of the heart coincides with the right side of the screen, where plane A should be rotated 180&#186; around the y-axis.</p>
      <p>The plane of the four heart chambers (A) was selected as a reference, this being rotated around the z-axis so that the cardiac apex was laid off in 6 hours; then the RENDER key was turned off with the reference point of the box laid on the middle third of the interventricular septum. Three virtual planes for the evaluation of the interventricular septum were used. Two planes were determined by the green line position (active) of the rendering box parallel to the outer edge of the interventricular septum, with the midpoint maintained in its middle third. We used the option six of the ROI selection, delimiting the septal region; by convention, we chose to view it through the left ventricular side. The rendered image was magnified and then the MEASURE key was pushed and the TRACE AREA option was selected to manually mark off the septal area in cm&#178;. The measurement of the septal area was performed during the initial phase of the ventricular diastole, when the septum was less contracted (<xref ref-type="fig" rid="en_aop02811f01-body3">Figure 1</xref>). The two-dimensional measure of the septal thickness was also obtained in four-chamber plane in mm (<xref ref-type="fig" rid="en_aop02811f02-body3">Figure 2</xref>).</p>
      <p content-type="asset">
        <fig id="en_aop02811f01-body3">
          <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf01-en.jpg"/></fig>
      </p>
      <p content-type="asset">
        <fig id="en_aop02811f02-body3">
          <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf02-en.jpg"/></fig>
      </p>
      <p>The data were stored in an Excel spreadsheet (Microsoft, Redmond, WA, USA) and analyzed using the program Statistical Package for the Social Sciences (SPSS) for Windows version 15.0 (SPSS Inc., Chicago, IL, USA). We calculated means, medians, standard deviations (SD), maximum and minimum values for each gestational interval evaluated, as well as the percentiles 5, 25, 50, 75 and 95. To assess the correlation between interventricular septum areas with gestational age (GA), scatter diagrams were determined by obtaining Pearson's correlation index (r), and the equation adjustment was given by the coefficient of determination (R2). For the construction of reference intervals for the interventricular septum areas as a function of gestational age, we followed the simple linear regression model<sup>14</sup> using the Altman's method<sup>15</sup> with a significance level of p &lt; 0.05. To assess the extent of septal thickness as a function of gestational age, we also used linear regression. To assess the correlation between the two-dimensional thickness of the interventricular septum and its area, we used the intraclass correlation coefficient (ICC). To calculate the intraobserver reproducibility, the same examiner (LCR) took another measurement of the septal area of 40 fetuses, with these measures blinded from the results of the former. For that purpose, we also used the ICC and Bland-Altman's plot<sup>16</sup>. The Bland-Altman's plot outlines the average of the two measurements performed by the same examiner against the difference in their averages with 95% of confidence interval of 1.96 SD of the average. In all analyses, a significance level of 0.05 will be used.</p>
      <p>
        <bold>Results</bold>
      </p>
      <p>We evaluated 69 pregnant women carrying normal fetuses between the 18<sup>th</sup> and the 33<sup>rd</sup> completed pregnancy week, and all met the inclusion criteria and were allocated in the final statistical analysis. Average maternal age was 29.8 years with sd &#177; 5.1, with an average of 1.4 pregnancies (SD &#177; 0.5) and average rate of 0.3 births (SD &#177; 0.5).</p>
      <p>The average area of the septal area was 0.47 &#177; 0.10 cm<sup>2</sup> (ranging from 0.36 to 0.59 cm<sup>2</sup>) in the 18<sup>th</sup> week to 2.42 &#177; 1.13 cm<sup>2</sup> (ranging from 1.26 to 3.92 cm<sup>2</sup>) in the 33<sup>rd</sup> pregnancy week. <xref ref-type="table" rid="en_aop02811t01-body3">Table 1</xref> shows the means, medians, standard deviations and minimum and maximum values of the interventricular septum area, while <xref ref-type="table" rid="en_aop02811t02-body3">Table 2</xref> shows the percentiles 5, 25, 50, 75 and 95 in each gestational interval evaluated.</p>
      <p content-type="asset">
        <table-wrap id="en_aop02811t01-body3">
          <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gt01-en.jpg"/></table-wrap>
      </p>
      <p content-type="asset">
        <table-wrap id="en_aop02811t02-body3">
          <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gt02-en.jpg"/></table-wrap>
      </p>
      <p>The septal area showed a strong correlation with the gestational age (r = 0.81). We performed polynomial regression models. The best adjustment with the exponential equation was: interventricular septum area = 0.125 x IG + 0.043, with R<sup>2</sup> = 0.65 (<xref ref-type="fig" rid="f3-body3">Figure 3</xref>).</p>
      <fig id="f3-body3">
        <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf03-en.jpg"/></fig>
      <p>In 52 patients, the septal thickness measurement was taken in the two-dimensional mode, but it did not present a significant correlation with gestational age (R&#178; = 0.20), showing an almost linear pattern between the 18<sup>th</sup> and the 33<sup>rd</sup> complete pregnancy week (<xref ref-type="fig" rid="f4-body3">Figure 4</xref>). Furthermore, there was no statistically significant correlation between the measaure of septal thickness and area in the gestational interval studied with ICC= 0.150 [95% CI -0.480; 0.512], with p &lt; 0.005.</p>
      <fig id="f4-body3">
        <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf04-en.jpg"/></fig>
      <p>There was an excellent intraobserver reproducibility for the measure of the interventricular septum area, with ICC = 0.994 (95% CI 0.988 to 0.997). The Bland-Altman's plot demonstrated this good reproducibility with the mean difference between the measurements of 0.01 cm<sup>2</sup> (SD &#177; 0.06 cm<sup>2</sup> and 95% CI &#177; 0.12 cm<sup>2</sup>) (<xref ref-type="fig" rid="f5-body3">Figure 5</xref>).</p>
      <fig id="f5-body3">
        <graphic xlink:href="1678-4170-abc-96-05-0386-00036-gf05-en.jpg"/></fig>
      <p>
        <bold>Discussion</bold>
      </p>
      <p>The STIC technology has been available on some US3D devices in mid-2010. STIC consists in the acquisition of the fetal heart volume with its vascular connections, allowing its evaluation in the multiplanar or rendered mode in the form of a cineloop sequence of a complete cardiac cycle. For the acquisition of the volume, we must select a region of interest (ROI), which determines the height and width of the volume, covering the entire heart with its vascular connections. Whenever possible, the acquisition should be performed with the fetus in the dorsal position (6 hours) and with no maternal breathing movements. The acquisition angle, which determines the depth of the volume varies with gestational age, and angles between 20&#186; and 25&#186; are sufficient in second-quarter fetuses. The acquisition time is determined by the operator, ranging from 7.5 to 15 seconds, and corresponds to the speed at which the transducer scans the ROI. The grayscale volume can be associated to the color Doppler mode, and post-processing such as the inversion mode and B-flow imaging<sup>8,17</sup>. The advantage of the STIC over dimensional echocardiography is that this method is less operator-dependent, allowing the identification of abnormalities in the outflow tracts of the fetal heart by examiners with little to intermediate experience<sup>18</sup>.</p>
      <p>Regarding the rendering of cardiac structures, Yagel et al<sup>19</sup> evaluated 136 pregnant women, of which 35 carried fetuses with cardiac anomalies, using the rendering method get planes for the evaluation of interatrial and interventricular septum, atrioventricular annulus and alignment of large vessels. In 13 fetuses with cardiac anomalies, the interventricular septum plane improved assessment of the septal defect, and in 4 of them, the atrial septum plane contributed to the evaluation of the foramen ovale. In five cases, the atrioventricular annulus plane immediately distal to the semilunar valves (coronal atrioventricular) improved the evaluation of the alignment of the large vessels in relation to the atrioventricular annulus, and in three of them, the evaluation of the semilunar valves, with or without malalignment of large vessels. Paladini et al<sup>20</sup> have recently evaluated a series of 30 cases of partial atrioventricular septal defects using in fetuses using echocardiography, and 14 of these cases was associated with STIC. In all of the cases, the echocardiographic markers for this anomaly were: ostium primum atrial septal defect and loss of normal appearance of the atrioventricular valves.</p>
      <p>Measuring the interventricular septum area is of particular importance in fetuses at risk for hypertrophic cardiomyopathy, such as the children of diabetic mothers, where there is significant thickening of the interventricular septum, causing obstructions in the left ventricular outflow tract<sup>21</sup>. The severity of symptoms of respiratory failure and congestive heart failure correlate with the severity of hypertrophic cardiomyopathy<sup>22,23</sup>. The measurement of the interventricular septum thickness has been traditionally performed by fetal echocardiography using the M mode<sup>10,11,24</sup>, however, this measure has inaccuracies, since the interventricular septum is not a uniform structure.</p>
      <p>In this study, we used the STIC technique to measure the interventricular septum area, a methodology so far unprecedented in the literature. The septum area was strongly correlated with gestational age, and intraobserver reproducibility was confirmed. The septal thickness measure revealed a weak correlation with gestational age, showing a virtually linear pattern of the measure between the 18<sup>th</sup> and 33<sup>th</sup> pregnancy week without showing a statistically significant correlation with the area obtained by the STIC. This result makes the septal area a potentially more reliable ultrasound parameter to measure the interventricular septum thickness in the diagnosis of septal hypertrophy.</p>
      <p>In summary, this study determined reference values for the fetal ventricular septal area, which can be applied to fetuses at risk for septal hypertrophy, such as the children of diabetic mothers, promoting early detection of morphological and functional changes in fetal hearts.</p>
      <p>
        <bold>References</bold>
      </p>
    </body>
  </sub-article>
</article>