<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">BcvttNwxp9wfrhgcVtf6TXQ</article-id>
      <article-id pub-id-type="other">00002</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2011000100002</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(11)09600102</article-id>
      <article-id pub-id-type="doi">10.1590/S0066-782X2010005000158</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigos Originais</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Disfun&#231;&#227;o do homoenxerto pulmonar utilizado na reconstru&#231;&#227;o do trato de sa&#237;da do ventr&#237;culo direito</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Lenzi</surname>
            <given-names>Andr&#233;a Weirich</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Olandoski</surname>
            <given-names>M&#225;rcia</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Ferreira</surname>
            <given-names>Wanderley Saviolo</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Sallum</surname>
            <given-names>Fabio Said</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Miyague</surname>
            <given-names>Nelson Itiro</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <addr-line>
          <named-content content-type="city">Curitiba</named-content>
          <named-content content-type="state">Paran&#225;</named-content>
        </addr-line>
        <institution content-type="orgname">Pontif&#237;cia Universidade Cat&#243;lica do Paran&#225;</institution>
        <institution content-type="orgdiv1">Hospital Pequeno Pr&#237;ncipe </institution>
        <country country="BR">Brazil</country>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>01</month>
        <year>2011</year>
      </pub-date>
      <volume>96</volume>
      <issue>1</issue>
      <fpage>02</fpage>
      <lpage>07</lpage>
      <history>
        <date date-type="rev-recd">
          <day>18</day>
          <month>02</month>
          <year>2010</year>
        </date>
        <date date-type="received">
          <day>20</day>
          <month>05</month>
          <year>2009</year>
        </date>
        <date date-type="accepted">
          <day>12</day>
          <month>03</month>
          <year>2010</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <abstract>
        <p>FUNDAMENTO: O homoenxerto pulmonar tem sido utilizado como uma op&#231;&#227;o na corre&#231;&#227;o de cardiopatia cong&#234;nita com obstru&#231;&#227;o da via de sa&#237;da do ventr&#237;culo direito. Os resultados em longo prazo, no entanto, mostram-se pouco satisfat&#243;rios. OBJETIVO: Identificar os fatores de risco associados &#224; disfun&#231;&#227;o e &#224; fal&#234;ncia do homoenxerto pulmonar. M&#201;TODOS: Estudo em crian&#231;as submetidas &#224; amplia&#231;&#227;o da via de sa&#237;da do ventr&#237;culo direito com homoenxerto pulmonar. As vari&#225;veis cl&#237;nicas, cir&#250;rgicas, evolutivas e de aspectos morfol&#243;gicos da pr&#243;tese foram analisadas como fatores de risco. RESULTADOS: A amostra final de 75 pacientes com idade mediana na cirurgia de 22 meses, variando de 1-157 meses, apresentou 13 pacientes (17,0%) que desenvolveram disfun&#231;&#227;o do homoenxerto, caracterizado por estenose ou insufici&#234;ncia pulmonar grave. O tempo de ocorr&#234;ncia entre o implante do homoenxerto e a detec&#231;&#227;o da disfun&#231;&#227;o foi de 45 &#177; 20 meses. Quando o tamanho do homoenxerto foi menor de 21 mm e o escore Z da valva pulmonar foi menor do que zero, ou maior do que tr&#234;s, foram considerados fatores de risco para a ocorr&#234;ncia de disfun&#231;&#227;o. CONCLUS&#195;O: O homoenxerto pulmonar de tamanho menor do que 21 mm e a valva pulmonar inadequada para idade e peso do paciente s&#227;o fatores determinantes para disfun&#231;&#227;o da pr&#243;tese.</p>
      </abstract>
      <kwd-group xml:lang="pt" kwd-group-type="author-generated">
        <kwd>Transplante hom&#243;logo</kwd>
        <kwd>ventr&#237;culos do cora&#231;&#227;o</kwd>
        <kwd>cardiopatias cong&#234;nitas</kwd>
      </kwd-group>
      <pub-date publication-format="electronic" date-type="pub">
        <day>10</day>
        <month>12</month>
        <year>2010</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>Disfun&#231;&#227;o do homoenxerto pulmonar utilizado na reconstru&#231;&#227;o do trato de sa&#237;da do ventr&#237;culo direito</p>
    <p>
      <bold>Andr&#233;a Weirich Lenzi; M&#225;rcia Olandoski; Wanderley Saviolo Ferreira; Fabio Said Sallum; Nelson Itiro Miyague</bold>
    </p>
    <p> Hospital Pequeno Pr&#237;ncipe, Pontificia Universidade Cat&#243;lica Paran&#225;, Curitiba, PR - Brasil</p>
    <p>
      <xref ref-type="corresp" rid="nt">Correspond&#234;ncia</xref>
    </p>
    <p>
      <bold>RESUMO</bold>
    </p>
    <p><bold>FUNDAMENTO:</bold> O homoenxerto pulmonar tem sido utilizado como uma op&#231;&#227;o na corre&#231;&#227;o de cardiopatia cong&#234;nita com obstru&#231;&#227;o da via de sa&#237;da do ventr&#237;culo direito. Os resultados em longo prazo, no entanto, mostram-se pouco satisfat&#243;rios. </p>
    <p><bold>OBJETIVO:</bold> Identificar os fatores de risco associados &#224; disfun&#231;&#227;o e &#224; fal&#234;ncia do homoenxerto pulmonar. </p>
    <p><bold>M&#201;TODOS:</bold> Estudo em crian&#231;as submetidas &#224; amplia&#231;&#227;o da via de sa&#237;da do ventr&#237;culo direito com homoenxerto pulmonar. As vari&#225;veis cl&#237;nicas, cir&#250;rgicas, evolutivas e de aspectos morfol&#243;gicos da pr&#243;tese foram analisadas como fatores de risco. </p>
    <p><bold>RESULTADOS:</bold> A amostra final de 75 pacientes com idade mediana na cirurgia de 22 meses, variando de 1-157 meses, apresentou 13 pacientes (17,0%) que desenvolveram disfun&#231;&#227;o do homoenxerto, caracterizado por estenose ou insufici&#234;ncia pulmonar grave. O tempo de ocorr&#234;ncia entre o implante do homoenxerto e a detec&#231;&#227;o da disfun&#231;&#227;o foi de 45 &#177; 20 meses. Quando o tamanho do homoenxerto foi menor de 21 mm e o escore Z da valva pulmonar foi menor do que zero, ou maior do que tr&#234;s, foram considerados fatores de risco para a ocorr&#234;ncia de disfun&#231;&#227;o. </p>
    <p><bold>CONCLUS&#195;O:</bold> O homoenxerto pulmonar de tamanho menor do que 21 mm e a valva pulmonar inadequada para idade e peso do paciente s&#227;o fatores determinantes para disfun&#231;&#227;o da pr&#243;tese.</p>
    <p><bold>Palavras-chave:</bold> Transplante hom&#243;logo/fisiopatologia, ventr&#237;culos do cora&#231;&#227;o, cardiopatias cong&#234;nitas/cirurgia.</p>
    <p>
      <bold>Introdu&#231;&#227;o</bold>
    </p>
    <p>O uso do homoenxerto no tratamento cir&#250;rgico das cardiopatias cong&#234;nitas teve seu inicio na d&#233;cada de 60, com Rastelli e col. (1964) e Ross e Somerville (1966). Nos anos iniciais, a alta taxa de calcifica&#231;&#227;o e estenose do enxerto provocou a busca de diferentes combina&#231;&#245;es de materiais para as cirurgias de reconstru&#231;&#227;o<sup>1</sup>.</p>
    <p>A partir da d&#233;cada de 80, com o aprimoramento das t&#233;cnicas de preparo e conserva&#231;&#227;o, o homoenxerto tornou-se o material de escolha em v&#225;rios servi&#231;os<sup>1</sup>. Apesar disso, a literatura ainda tem mostrado a necessidade de troca cir&#250;rgica pela ocorr&#234;ncia de estenose ou insufici&#234;ncia da pr&#243;tese. </p>
    <p>O servi&#231;o de cirurgia card&#237;aca pedi&#225;trica da Santa Casa de Curitiba utiliza, desde a d&#233;cada de 90, o homoenxerto pulmonar ou a&#243;rtico na corre&#231;&#227;o de cardiopatias cong&#234;nitas, obtendo bom resultado. </p>
    <p>A reconstru&#231;&#227;o da via de sa&#237;da do ventr&#237;culo direito com homoenxerto pulmonar teria melhor evolu&#231;&#227;o em m&#233;dio e longo prazo.</p>
    <p>O objetivo do estudo foi avaliar a influ&#234;ncia de diversos fatores de risco reconhecidos na literatura para a ocorr&#234;ncia de disfun&#231;&#227;o do homoenxerto em uma amostra de pacientes operados com enxerto desenvolvido em nosso meio.</p>
    <p>
      <bold>Material e m&#233;todos</bold>
    </p>
    <p>Para este estudo, avaliou-se 92 pacientes, operados no per&#237;odo de 1998-2005, que utilizaram homoenxerto do tipo pulmonar criopreservado na reconstru&#231;&#227;o da via de sa&#237;da do ventr&#237;culo direito, ou na substitui&#231;&#227;o de um heteroenxerto colocado nesta posi&#231;&#227;o em cirurgia pr&#233;via. </p>
    <p>O homoenxerto pulmonar criopreservado foi fornecido pelo Banco de Valvas Card&#237;acas Humanas da Santa Casa de Curitiba.</p>
    <p>Foram exclu&#237;dos deste estudo os pacientes que usaram o homoenxerto pulmonar na reconstru&#231;&#227;o do trato de sa&#237;da esquerdo, como nas cirurgias de Norwood e na interrup&#231;&#227;o do arco a&#243;rtico ou nas cirurgias de anastomose cavopulmonar. Al&#233;m daqueles com dados incompletos em seus prontu&#225;rios.</p>
    <p>Em seus prontu&#225;rios, foram coletados os dados referentes ao sexo, tipo de cardiopatia, presen&#231;a de altera&#231;&#227;o da &#225;rvore pulmonar, tipo sangu&#237;neo, idade na primeira consulta e no momento da cirurgia, cirurgia pr&#233;via, o tempo de acompanhamento ambulatorial e resultado de exames realizados na institui&#231;&#227;o, como ecocardiograma Doppler colorido e cateterismo card&#237;aco. </p>
    <p>Os dados da parte cir&#250;rgica analisados foram: tamanhos de homoenxerto, tipo sangu&#237;neo doador, valor Z da valva pulmonar, a manuten&#231;&#227;o da integridade do homoenxerto, o tempo de extracorp&#243;rea e o tempo de clampeamento a&#243;rtico. Os dados do p&#243;s-operat&#243;rio foram: as intercorr&#234;ncias durante a perman&#234;ncia na unidade de terapia intensiva e a ocorr&#234;ncia de &#243;bito no p&#243;s-operat&#243;rio imediato. </p>
    <p>O valor Z da valva pulmonar relaciona o tamanho do homoenxerto em mil&#237;metros com a superf&#237;cie corp&#243;rea do paciente. O valor Z da valva pulmonar igual a zero significa o tamanho ideal do homoenxerto para a superf&#237;cie corp&#243;rea do paciente. Os valores negativos e positivos significam um desvio-padr&#227;o para mais ou para menos do valor ideal. </p>
    <p>A integridade do homoenxerto pulmonar pode ser alterada pelo cirurgi&#227;o, diminuindo-se o tamanho do anel valvar, retirando-se uma das c&#250;spides ou substituindo-se as c&#250;spides por uma monoc&#250;spide de homoenxerto, ou outro material.</p>
    <p>As cirurgias foram realizadas pela mesma equipe cir&#250;rgica, e alguns pacientes, antes da cirurgia de corre&#231;&#227;o total, necessitaram de cirurgias paliativas.</p>
    <p>Do acompanhamento ambulatorial, analisou-se a insufici&#234;ncia ou a estenose pulmonar, medidas por meio de exames ecocardiogr&#225;ficos e classificados em leve, moderada e grave. A insufici&#234;ncia ou estenose grave do homoenxerto foi designada como disfun&#231;&#227;o.</p>
    <p>A insufici&#234;ncia grave foi considerada como regurgita&#231;&#227;o que abrange totalmente o di&#226;metro do anel pulmonar e com refluxo diast&#243;lico no Doppler colorido em ramos das art&#233;rias pulmonares. A estenose grave foi considerada como um gradiente sist&#243;lico instant&#226;neo e m&#225;ximo no Doppler maior do que 50 mmHg. </p>
    <p>A exist&#234;ncia de refluxo de discreta abrang&#234;ncia do anel definiu-se como insufici&#234;ncia pulmonar leve. A insufici&#234;ncia pulmonar moderada foi definida quando havia regurgita&#231;&#227;o de cerca de metade do di&#226;metro do anel valvar com refluxo diast&#243;lico no Doppler colorido em tronco da art&#233;ria pulmonar. A estenose pulmonar leve foi considerada na presen&#231;a de gradiente sist&#243;lico pulmonar instant&#226;neo m&#225;ximo no Doppler menor do que 30 mmHg e moderada entre 30-50 mmHg.</p>
    <p>Considerou-se como fal&#234;ncia do homoenxerto a necessidade de troca do homoenxerto pulmonar por via cir&#250;rgica devido a sua disfun&#231;&#227;o (insufici&#234;ncia ou estenose severa). </p>
    <p>Para a compara&#231;&#227;o das curvas de tempo at&#233; a ocorr&#234;ncia de disfun&#231;&#227;o de homoenxerto, foi usado o teste de <italic>Log-rank</italic>. Os casos que at&#233; a &#250;ltima avalia&#231;&#227;o ecocardiogr&#225;fica n&#227;o haviam apresentado disfun&#231;&#227;o do homoenxerto foram considerados censurados. Na an&#225;lise univariada, foram analisadas as vari&#225;veis sexo, idade &#224; &#233;poca da cirurgia, tipo de cardiopatia, tamanho de homoenxerto, valor Z da valva pulmonar, compatibilidade sangu&#237;nea, altera&#231;&#227;o da anatomia da &#225;rvore pulmonar, cirurgia pr&#233;via, tempo de extracorp&#243;rea e tempo de clampeamento a&#243;rtico.</p>
    <p>Para avalia&#231;&#227;o conjunta de fatores, foram ajustado um modelo de Regress&#227;o de Cox e estimados os valores de risco relativo e intervalos de 95,0% de confian&#231;a. Curvas de Kaplan-Meier foram constru&#237;das para apresentar as curvas de tempo para a disfun&#231;&#227;o de homoenxerto. Valores de p &lt; 0,05 indicaram signific&#226;ncia estat&#237;stica. Os dados foram organizados em planilha Excel e analisados com o uso do programa computacional <italic>Statistica</italic> v.8.0.</p>
    <p>
      <bold>Resultados</bold>
    </p>
    <p>Analisaram-se os prontu&#225;rios dos 92 pacientes submetidos &#224; corre&#231;&#227;o cir&#250;rgica da cardiopatia com utiliza&#231;&#227;o de homoenxerto pulmonar criopreservado no trato de sa&#237;da do ventr&#237;culo direito.</p>
    <p>A idade m&#233;dia dos pacientes na primeira consulta foi de 14,3 &#177; 4,2 meses. Quarenta pacientes foram atendidos no primeiro m&#234;s de vida e 66 durante o primeiro ano de vida. Dos pacientes, 56% eram do sexo feminino. </p>
    <p>As cardiopatias est&#227;o relacionadas na <xref ref-type="table" rid="tab01">Tabela 1</xref>. Os pacientes com tetralogia de Fallot, que utilizaram o homoenxerto pulmonar, foram os com agenesia da valva pulmonar ou com hipoplasia de anel e tronco pulmonar.</p>
    <table-wrap id="tab01">
      <graphic xlink:href="1678-4170-abc-96-01-0002-00158-gt01.jpg"/></table-wrap>
    <p>O tempo de acompanhamento ambulatorial desses pacientes foi de 106 &#177; 62,7 meses, com mediana de 89 meses, variando de 24 meses a 272 meses.</p>
    <p>A idade m&#233;dia dos pacientes no momento da cirurgia de corre&#231;&#227;o da cardiopatia foi de 40,3 &#177; 42,3 meses, com mediana de 22 meses, variando de 1 m&#234;s a 157 meses. Trinta por cento da amostra (28 casos) operaram abaixo de um ano de idade, havendo varia&#231;&#227;o nas idades de corre&#231;&#227;o total conforme a cardiopatia.</p>
    <p>Em 8 pacientes, realizou-se a troca de um tubo de peric&#225;rdio bovino colocado em cirurgia pr&#233;via por um homoenxerto pulmonar, em m&#233;dia 110,5 &#177; 24,3 meses ap&#243;s a cirurgia inicial.</p>
    <p>Em 46,0% dos pacientes, a &#225;rvore pulmonar mostrava altera&#231;&#245;es como estenose de ramo, aus&#234;ncia de ramo, ramos pulmonares aneurism&#225;ticos ou presen&#231;a de efeitos colaterais sist&#234;micos pulmonares.</p>
    <p>O homoenxerto pulmonar utilizado nas cirurgias variou seu tamanho de 12 a 26 mm, com m&#233;dia de 21,5 &#177; 3,2 mm e mediana de 22 mm. O valor Z da valva pulmonar variou de menos um a 5, com media de 2,8 &#177; 1,4 e mediana de 3. Cinquenta e sete por cento dos homoenxertos tiveram seu valor <italic>Z </italic>entre 0 e mais 3.</p>
    <p>A integridade do homoenxerto pulmonar na coloca&#231;&#227;o variou conforme o paciente. Em 11 casos (12,0% da amostra), houve altera&#231;&#227;o do homoenxerto pulmonar para sua melhor adaptabilidade: 9 casos utilizaram uma monocuspide do homoenxerto e dois casos uma monocuspide de goretex. </p>
    <p>Em 47 pacientes, utilizou-se um teto, de hemashield ou peric&#225;rdio bovino, para fazer a liga&#231;&#227;o do ventr&#237;culo direito com o homoenxerto pulmonar. Em 30,0% dos pacientes, houve compatibilidade sangu&#237;nea entre o doador do homoenxerto e o receptor. </p>
    <p>Em 56,0% dos pacientes, o tempo de extracorp&#243;rea esteve acima dos 120 minutos, com m&#233;dia de 135 &#177; 44,6 minutos. Em 62,0% dos casos, o tempo clampeamento de aorta manteve-se acima de 80 minutos, com m&#233;dia de 99,5 &#177; 34,2 minutos.</p>
    <p>Houve 17 casos de &#243;bito precoce, 11 destes por fal&#234;ncia de m&#250;ltiplos &#243;rg&#227;os e dois &#243;bitos tardios. </p>
    <p>A disfun&#231;&#227;o do homoenxerto pulmonar na avalia&#231;&#227;o ambulatorial apresentou-se em 13 pacientes (17,0% da amostra) e, destes, 5 foram submetidos &#224; troca cir&#250;rgica do homoenxerto. </p>
    <p>Dez pacientes apresentavam estenose grave do homoenxerto pulmonar com gradiente sist&#243;lico m&#233;dio 67 &#177; 22 mmHg, variando de 50 mmhg a 127 mmHg, e tr&#234;s pacientes tinham insufici&#234;ncia pulmonar grave.</p>
    <p>Para os pacientes com disfun&#231;&#227;o do homoenxerto, o tempo da cirurgia at&#233; a ocorr&#234;ncia da disfun&#231;&#227;o foi em m&#233;dia 45,4 &#177; 20,3 meses com mediana de 36 meses, variando de 7 a 86 meses. </p>
    <p>Para tr&#234;s anos, a sobrevida livre de disfun&#231;&#227;o foi de 90,0%, para 5 anos, foi de 84,0% e, para 7 anos, foi de 80,0%. A sobrevida livre de troca cir&#250;rgica do homoenxerto foi, para 3 anos, de 96,0%, para 5 anos, foi de 94,0% e para 7 anos de 93,0%. </p>
    <p>Apenas o tamanho do homoenxerto, igual ou menor do que 21 mm, esteve implicado na disfun&#231;&#227;o grave do homoenxerto, tendo uma sobrevida livre de disfun&#231;&#227;o em 5 anos de 45,0% para este tamanho, e de 80,0% para os homoenxertos acima de 21 mm (p = 0,009) (<xref ref-type="fig" rid="f01">Gr&#225;fico 1</xref>).</p>
    <p content-type="asset">
      <fig id="f01">
        <graphic xlink:href="1678-4170-abc-96-01-0002-00158-gf01.jpg"/></fig>
    </p>
    <p>O valor Z da valva pulmonar revelou que, para as medidas entre zero e mais tr&#234;s, a taxa para ocorr&#234;ncia de disfun&#231;&#227;o em 5 anos foi de 22,0%, e, para as medidas abaixo de zero ou acima de mais tr&#234;s, foi 65,0% (p = 0,09) (<xref ref-type="fig" rid="f02">Gr&#225;fico 2</xref>).</p>
    <p content-type="asset">
      <fig id="f02">
        <graphic xlink:href="1678-4170-abc-96-01-0002-00158-gf02.jpg"/></fig>
    </p>
    <p>Na regress&#227;o Cox, a vari&#225;vel implicada na disfun&#231;&#227;o do homoenxerto foi o tamanho, onde o homoenxerto com tamanho menor ou igual a 21 mm teve risco 3,7 vezes maior de que a disfun&#231;&#227;o do homoenxerto acima 21 mm (<xref ref-type="table" rid="tab02">Tabela 2</xref>).</p>
    <table-wrap id="tab02">
      <graphic xlink:href="1678-4170-abc-96-01-0002-00158-gt02.jpg"/></table-wrap>
    <p>
      <bold>Discuss&#227;o</bold>
    </p>
    <p>Nos &#250;ltimos anos, o servi&#231;o de cirurgia card&#237;aca do Hospital Pequeno Pr&#237;ncipe de Curitiba optou pelo emprego do homoenxerto pulmonar para reconstru&#231;&#227;o do trato de sa&#237;da do ventr&#237;culo direito devido &#224;s suas vantagens t&#233;cnicas e aos bons resultados cl&#237;nicos e cir&#250;rgicos de pacientes j&#225; operados<sup>2,3</sup>.</p>
    <p>A op&#231;&#227;o desse servi&#231;o pelo uso do homoenxerto pulmonar, em tal posi&#231;&#227;o, est&#225; baseada em estudos que mostram que o homoenxerto a&#243;rtico em posi&#231;&#227;o pulmonar apresenta maior &#237;ndice de calcifica&#231;&#227;o devido a sua composi&#231;&#227;o rica em elastina<sup>4-15</sup>.</p>
    <p>Do ponto de vista cir&#250;rgico, o homoenxerto pulmonar est&#225; dispon&#237;vel em tamanhos pequenos, tem maior capacidade hemost&#225;tica, maior maleabilidade e facilidade de manuseio para o cirurgi&#227;o, seus ramos podem ser usados para amplia&#231;&#227;o de &#225;reas esten&#243;ticas nas art&#233;rias pulmonares, dispensa anticoagula&#231;&#227;o cr&#244;nica, apresenta maior resist&#234;ncia &#224; endocardite e possui uma potencial viabilidade para o segundo reparo<sup>5,7,10,11,15-18</sup>.</p>
    <p>Na maioria dos casos, a deteriora&#231;&#227;o do homoenxerto acontece por estenose devido &#224; calcifica&#231;&#227;o<sup>1</sup>. A taxa de fal&#234;ncia do homoenxerto varia conforme o estudo, sendo, em 5 anos, entre 10,0-40,0%<sup>5,14</sup> dos homoenxertos implantados e, em 10 anos, entre 46,0-65,0%<sup>4,7</sup>.</p>
    <p>Dos fatores risco implicados na deteriora&#231;&#227;o do homoenxerto, o tipo de cardiopatia &#233; um deles. Forbess e cols.<sup>19</sup>, Bando e cols.<sup>9</sup> e Dearanie cols.<sup>4 </sup>acharam uma maior taxa de fal&#234;ncia do homoenxerto associado a cardiopatias como <italic>truncus arteriosus</italic>, transposi&#231;&#227;o das grandes art&#233;rias com estenose pulmonar e dupla via de sa&#237;da do ventr&#237;culo direito, no entanto, neste estudo, n&#227;o houve correla&#231;&#227;o da durabilidade do homoenxerto com o tipo de cardiopatia.</p>
    <p>Na idade jovem, &#224; coloca&#231;&#227;o do homoenxerto &#233; considerada um fator de risco para a fal&#234;ncia do conduto<sup>4,5,8,9,12,14,15,18-21</sup>. Os motivos para isto s&#227;o diversos, e, entre eles, est&#227;o o padr&#227;o crescimento acelerado da crian&#231;a, a utiliza&#231;&#227;o de homoenxertos de tamanhos menores e a resposta imunol&#243;gica exacerbada na crian&#231;a. Em nosso estudo, n&#227;o houve diferen&#231;a na durabilidade dos homoenxertos colocados em crian&#231;as abaixo de um ano e acima de um ano de idade. </p>
    <p>Um dos pontos mais discutidos &#233; o tamanho do homoenxerto utilizado e sua influ&#234;ncia na durabilidade. O homoenxerto pulmonar de tamanho pequeno &#233; associado a uma maior taxa de disfun&#231;&#227;o e de troca cir&#250;rgica<sup>4,5,14,15,18,19,21-24 </sup>.</p>
    <p>Nosso trabalho demonstrou que o uso de homoenxerto pulmonar menor do que 21 mm tem uma maior probabilidade de disfun&#231;&#227;o, ou seja, o homoenxerto abaixo de 21 mm tem 3,7 vezes mais risco de desenvolver disfun&#231;&#227;o que o acima de 21 mm. A sobrevida livre de disfun&#231;&#227;o, em 5 anos, para um homoenxerto menor de 21 mm &#233; de 55,0% e, acima de 21 mm, &#233; de 85,0%.</p>
    <p>Outros estudos j&#225; haviam relatado que o tamanho do homoenxerto &#233; um fator de risco para disfun&#231;&#227;o. Bielefeld e cols.<sup>15</sup> demonstraram que a ocorr&#234;ncia de disfun&#231;&#227;o em homoenxerto acima de 20 mm &#233; baixa. Razzouke cols.<sup>24</sup> afirmam que homoenxerto acima de 24 mm tem sobrevida livre de troca cir&#250;rgica maior e Boethige cols.<sup>21</sup> mostram que o homoenxerto abaixo de 20 mm &#233; menos dur&#225;vel em crian&#231;as e desenvolve gradiente de estenose mais rapidamente.</p>
    <p>O valor Z pequeno da valva pulmonar tamb&#233;m &#233; implicado na disfun&#231;&#227;o do homoenxerto<sup>7,8,20</sup>. A taxa maior de disfun&#231;&#227;o em nosso estudo foi para um valor Z abaixo de zero e acima de mais tr&#234;s, enfim, os melhores resultados foram obtidos quando o tamanho da valva pulmonar ficou entre o valor Z zero e mais tr&#234;s. Assim sendo, alguns centros, incluindo o nosso Servi&#231;o, t&#234;m utilizado um homoenxerto de maior n&#250;mero poss&#237;vel para a crian&#231;a, na tentativa de compensar o crescimento natural da mesma com uma valva de maior tamanho e diminuir a incid&#234;ncia de disfun&#231;&#227;o e troca cir&#250;rgica<sup>7,14,20,21,25,26</sup>.</p>
    <p>Neste trabalho, outros fatores de risco para disfun&#231;&#227;o da pr&#243;tese, conhecidos na literatura como compatibilidade sangu&#237;nea entre doador e receptor, altera&#231;&#227;o da anatomia da &#225;rvore pulmonar, cirurgia card&#237;aca com amplia&#231;&#227;o pr&#233;via, utiliza&#231;&#227;o do homoenxerto &#237;ntegro ou a substitui&#231;&#227;o de uma de suas partes, sexo do paciente, tempo de extracorp&#243;rea e a idade &#224; cirurgia n&#227;o tiveram influ&#234;ncia na durabilidade do homoenxerto.</p>
    <p>
      <bold>Conclus&#227;o</bold>
    </p>
    <p>A utiliza&#231;&#227;o do homoenxerto pulmonar para amplia&#231;&#227;o do trato de sa&#237;da do ventr&#237;culo direito apresenta bons resultados, com uma taxa de disfun&#231;&#227;o de 17,0% dos casos. Este estudo mostrou menor chance de disfun&#231;&#227;o com implante de um homoenxerto pulmonar acima de 21 mm e um valor Z da valva pulmonar compreendido entre zero e mais tr&#234;s.</p>
    <p>
      <bold>Potencial Conflito de Interesses</bold>
    </p>
    <p>Declaro n&#227;o haver conflito de interesses pertinentes.</p>
    <p>
      <bold>Fontes de Financiamento</bold>
    </p>
    <p>O presente estudo n&#227;o teve fontes de financiamento externas.</p>
    <p>
      <bold>Vincula&#231;&#227;o Acad&#234;mica</bold>
    </p>
    <p>Este artigo &#233; parte de tese de mestrado de Andr&#233;a Weirich Lenzi pela Pontif&#237;cia Universidade Cat&#243;lica do Paran&#225;.</p>
    <p>
      <fn id="nt" fn-type="corresp">
        <p>Correspond&#234;ncia:</p>
        <p> Andr&#233;a Weirich Lenzi </p>
        <p> Rua Vicente Machado, 690/03 - Batel </p>
        <p> 80420-011 - Curitiba, PR - Brasil </p>
        <p> E-mail: </p>
        <p>
          <email xlink:href="andreawlenzi@yahoo.com.br">andreawlenzi@yahoo.com.br</email>
        </p>
      </fn>
    </p>
    <p>Artigo recebido em 20/05/09 </p>
    <p> revisado recebido em 18/02/10 </p>
    <p> aceito em 12/03/10</p>
  </body>
  <back>
    <ref-list>
      <ref id="B1">
        <mixed-citation>1. Stark J. The use of valved conduits in pediatric cardiac surgery. Pediatr Cardiol. 1998; 19 (4): 282-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>The use of valved conduits in pediatric cardiac surgery</article-title>
          <source>Pediatr Cardiol</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>282</fpage>
          <lpage>8</lpage>
          <issue>4</issue>
          <volume>19</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Stark</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Costa F, Dohmen P, Vieira E. Opera&#231;&#227;o de Ross com homoenxertos valvares descelularizados: resultados de m&#233;dio prazo. Rev Bras Cir Cardiovasc. 2007; 22 (4): 454-62.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Opera&#231;&#227;o de Ross com homoenxertos valvares descelularizados: resultados de m&#233;dio prazo</article-title>
          <source>Rev Bras Cir Cardiovasc</source>
          <date>
            <year>2007</year>
          </date>
          <fpage>454</fpage>
          <lpage>62</lpage>
          <issue>4</issue>
          <volume>22</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Costa</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Dohmen</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Vieira</surname>
              <given-names>E</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. Giffhorn H, Ferreira W, Costa F. Avalia&#231;&#227;o inicial de homoenxertos em posi&#231;&#227;o pulmonar em crian&#231;as e adolescentes. Rev Bras Cir Cardiovasc. 1999; 14 (2): 121-7.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Avalia&#231;&#227;o inicial de homoenxertos em posi&#231;&#227;o pulmonar em crian&#231;as e adolescentes</article-title>
          <source>Rev Bras Cir Cardiovasc</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>121</fpage>
          <lpage>7</lpage>
          <issue>2</issue>
          <volume>14</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Giffhorn</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Ferreira</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Costa</surname>
              <given-names>F</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Dearani J, Danielson GK, Puga FJ, Schaff HV, Warnes CW, Drescoll DI, et al. Late follow up of 109 patients undergoing operation for complex congenital heart disease utilizing pulmonary ventricle to pulmonary artery conduits. Ann Thorac Surg. 2003; 75 (2): 399-411.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Late follow up of 109 patients undergoing operation for complex congenital heart disease utilizing pulmonary ventricle to pulmonary artery conduits</article-title>
          <source>Ann Thorac Surg</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>399</fpage>
          <lpage>411</lpage>
          <issue>2</issue>
          <volume>75</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Dearani</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Danielson</surname>
              <given-names>GK</given-names>
            </name>
            <name>
              <surname>Puga</surname>
              <given-names>FJ</given-names>
            </name>
            <name>
              <surname>Schaff</surname>
              <given-names>HV</given-names>
            </name>
            <name>
              <surname>Warnes</surname>
              <given-names>CW</given-names>
            </name>
            <name>
              <surname>Drescoll</surname>
              <given-names>DI</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. Niwaya K, Knott-Craig CJ, Lane MM, Chandrasekaren K, Overhoet ED, Elkins RC. Cryopreserved homograft valves in the pulmonary position: risk analysis for intermediate-term failure. J Thorac Cardiovasc Surg. 1999; 117: 141-7.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Cryopreserved homograft valves in the pulmonary position: risk analysis for intermediate-term failure</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>141</fpage>
          <lpage>7</lpage>
          <volume>117</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Niwaya</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Knott-Craig</surname>
              <given-names>CJ</given-names>
            </name>
            <name>
              <surname>Lane</surname>
              <given-names>MM</given-names>
            </name>
            <name>
              <surname>Chandrasekaren</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Overhoet</surname>
              <given-names>ED</given-names>
            </name>
            <name>
              <surname>Elkins</surname>
              <given-names>RC</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B6">
        <mixed-citation>6. Stark J, Bull C, Stajevic M, Jothl M, Elliot M, de Leval M. Fate of subpulmonary homograft conduits: determinants of late failure. J Thorac Cardiovasc Surg. 1998; 115: 506-16.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Fate of subpulmonary homograft conduits: determinants of late failure</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>506</fpage>
          <lpage>16</lpage>
          <volume>115</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Stark</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Bull</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Stajevic</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Jothl</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Elliot</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>de Leval</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B7">
        <mixed-citation>7. Mohammdi S, Belli E, Martinovic I, Honyel L, Capderon A, Petit J, et al. Surgery for right ventricle to pulmonary artery conduit obstruction: risk factors for further reoperation. Eur J Cardiothorac Surg. 2005; 28: 217-22.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Surgery for right ventricle to pulmonary artery conduit obstruction: risk factors for further reoperation</article-title>
          <source>Eur J Cardiothorac Surg</source>
          <date>
            <year>2005</year>
          </date>
          <fpage>217</fpage>
          <lpage>22</lpage>
          <volume>28</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Mohammdi</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Belli</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Martinovic</surname>
              <given-names>I</given-names>
            </name>
            <name>
              <surname>Honyel</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Capderon</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Petit</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B8">
        <mixed-citation>8. Caldarone CA, McCrindle BW, Van Arsdell GS, Coles JG, Welb G, Freedom RM, et al. Independent factors associated with longevity of prosthetic pulmonary valves and valved conduits. J Thorac Cardiovasc Surg. 2000; 120: 1022-31.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Independent factors associated with longevity of prosthetic pulmonary valves and valved conduits</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>1022</fpage>
          <lpage>31</lpage>
          <volume>120</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Caldarone</surname>
              <given-names>CA</given-names>
            </name>
            <name>
              <surname>McCrindle</surname>
              <given-names>BW</given-names>
            </name>
            <name>
              <surname>Van Arsdell</surname>
              <given-names>GS</given-names>
            </name>
            <name>
              <surname>Coles</surname>
              <given-names>JG</given-names>
            </name>
            <name>
              <surname>Welb</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Freedom</surname>
              <given-names>RM</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B9">
        <mixed-citation>9. Bando K, Danielson GK, Schaff HV, Mair DD, Jubsrud PR, Puga FJ. Outcome of pulmonary and aortic homografts for right ventricular outflow tract reconstruction. J Thorac Cardiovasc Surg. 1995; 109 (3): 509-17.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Outcome of pulmonary and aortic homografts for right ventricular outflow tract reconstruction</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>509</fpage>
          <lpage>17</lpage>
          <issue>3</issue>
          <volume>109</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Bando</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Danielson</surname>
              <given-names>GK</given-names>
            </name>
            <name>
              <surname>Schaff</surname>
              <given-names>HV</given-names>
            </name>
            <name>
              <surname>Mair</surname>
              <given-names>DD</given-names>
            </name>
            <name>
              <surname>Jubsrud</surname>
              <given-names>PR</given-names>
            </name>
            <name>
              <surname>Puga</surname>
              <given-names>FJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B10">
        <mixed-citation>10. Albert JD, Bishop DA, Fullerton DA, Campbell DN, Clark DR. Conduit reconstruction of the right ventricular outflow tract. J Thorac Cardiovasc Surg. 1993; 106 (2): 228-36.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Conduit reconstruction of the right ventricular outflow tract</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <date>
            <year>1993</year>
          </date>
          <fpage>228</fpage>
          <lpage>36</lpage>
          <issue>2</issue>
          <volume>106</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Albert</surname>
              <given-names>JD</given-names>
            </name>
            <name>
              <surname>Bishop</surname>
              <given-names>DA</given-names>
            </name>
            <name>
              <surname>Fullerton</surname>
              <given-names>DA</given-names>
            </name>
            <name>
              <surname>Campbell</surname>
              <given-names>DN</given-names>
            </name>
            <name>
              <surname>Clark</surname>
              <given-names>DR</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B11">
        <mixed-citation>11. Jashari R, Daenen W, Vanderkelen A, Meyns B. Is ABO group incompatibility really the reason of accelerated failure of cryopreservaded allografts in very young patients ? Cell and Tissue Banking. 2004; 5 (4): 253-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Is ABO group incompatibility really the reason of accelerated failure of cryopreservaded allografts in very young patients</article-title>
          <source>Cell and Tissue Banking</source>
          <date>
            <year>2004</year>
          </date>
          <fpage>253</fpage>
          <lpage>9</lpage>
          <issue>4</issue>
          <volume>5</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Jashari</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Daenen</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Vanderkelen</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Meyns</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B12">
        <mixed-citation>12. Basket RJ, Nanton MA, Warren AE. Human leukocyte antigen-DR and ABO mismatch are associated with accelerated homograft valve failure in children: implications for therapeutics interventions. J Thorac Cardiovasc Surg. 2003; 126 (1): 232-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Human leukocyte antigen-DR and ABO mismatch are associated with accelerated homograft valve failure in children: implications for therapeutics interventions</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>232</fpage>
          <lpage>9</lpage>
          <issue>1</issue>
          <volume>126</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Basket</surname>
              <given-names>RJ</given-names>
            </name>
            <name>
              <surname>Nanton</surname>
              <given-names>MA</given-names>
            </name>
            <name>
              <surname>Warren</surname>
              <given-names>AE</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B13">
        <mixed-citation>13. Cleveland DC, Williams WG, Razzouk AJ, Tusler GA, Rebeyka IM, Duffy L, et al. Failure of cryopreserved homograft valved conduits in the pulmonary circulation. Circulation. 1992; 86 (5 Suppl II):150-3.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Failure of cryopreserved homograft valved conduits in the pulmonary circulation</article-title>
          <source>Circulation</source>
          <date>
            <year>1992</year>
          </date>
          <fpage>150</fpage>
          <lpage>3</lpage>
          <volume>86</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Cleveland</surname>
              <given-names>DC</given-names>
            </name>
            <name>
              <surname>Williams</surname>
              <given-names>WG</given-names>
            </name>
            <name>
              <surname>Razzouk</surname>
              <given-names>AJ</given-names>
            </name>
            <name>
              <surname>Tusler</surname>
              <given-names>GA</given-names>
            </name>
            <name>
              <surname>Rebeyka</surname>
              <given-names>IM</given-names>
            </name>
            <name>
              <surname>Duffy</surname>
              <given-names>L</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B14">
        <mixed-citation>14. Brown JW, Ruzmetov M, Rodefeld MD, Vijoy P, Turrentine MW. Right ventricular outflow tract reconstruction with an allograft conduit in non-Ross patients: risk factors for allograft dysfunction and failure. Ann Thorac Surg. 2005; 80 (2): 655-64.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Right ventricular outflow tract reconstruction with an allograft conduit in non-Ross patients: risk factors for allograft dysfunction and failure</article-title>
          <source>Ann Thorac Surg</source>
          <date>
            <year>2005</year>
          </date>
          <fpage>655</fpage>
          <lpage>64</lpage>
          <issue>2</issue>
          <volume>80</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Brown</surname>
              <given-names>JW</given-names>
            </name>
            <name>
              <surname>Ruzmetov</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Rodefeld</surname>
              <given-names>MD</given-names>
            </name>
            <name>
              <surname>Vijoy</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Turrentine</surname>
              <given-names>MW</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B15">
        <mixed-citation>15. Bielefeld MR, Bishop DA, Campbell DN, Mitchell MB, Crover FL, Clarke DR. Reoperative homograft right ventricular outflow tract reconstruction. Ann Thorac Surg. 2001; 71: 482-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Reoperative homograft right ventricular outflow tract reconstruction</article-title>
          <source>Ann Thorac Surg</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>482</fpage>
          <lpage>8</lpage>
          <volume>71</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Bielefeld</surname>
              <given-names>MR</given-names>
            </name>
            <name>
              <surname>Bishop</surname>
              <given-names>DA</given-names>
            </name>
            <name>
              <surname>Campbell</surname>
              <given-names>DN</given-names>
            </name>
            <name>
              <surname>Mitchell</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Crover</surname>
              <given-names>FL</given-names>
            </name>
            <name>
              <surname>Clarke</surname>
              <given-names>DR</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B16">
        <mixed-citation>16. Levive AJ, Miller PA, Stumper OS. Early results of right ventricular-pulmonary artery conduits in patients under 1 year of age. Eur J Cardiothorac Surg. 2001; 19 (2): 122-6.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Early results of right ventricular-pulmonary artery conduits in patients under 1 year of age</article-title>
          <source>Eur J Cardiothorac Surg</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>122</fpage>
          <lpage>6</lpage>
          <issue>2</issue>
          <volume>19</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Levive</surname>
              <given-names>AJ</given-names>
            </name>
            <name>
              <surname>Miller</surname>
              <given-names>PA</given-names>
            </name>
            <name>
              <surname>Stumper</surname>
              <given-names>OS</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B17">
        <mixed-citation>17. Hopkins RA, Reyes II A, Imperato DA. Ventricular outflow tract reconstructions with cryopreserved cardiac valved homografts: a single surgeon's 10-year experience. Ann Surg. 1996; 223 (5): 544-54.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Ventricular outflow tract reconstructions with cryopreserved cardiac valved homografts: a single surgeon's 10-year experience</article-title>
          <source>Ann Surg</source>
          <date>
            <year>1996</year>
          </date>
          <fpage>544</fpage>
          <lpage>54</lpage>
          <issue>5</issue>
          <volume>223</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Hopkins</surname>
              <given-names>RA</given-names>
            </name>
            <name>
              <surname>Reyes II</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Imperato</surname>
              <given-names>DA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B18">
        <mixed-citation>18. Tabete S, Nagakura S, Boyle ME Jr, Duncan BW. Right ventricle to pulmonary artery reconstruction using a valved homograft. Circ J. 2003; 67 (2): 906-12.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Right ventricle to pulmonary artery reconstruction using a valved homograft</article-title>
          <source>Circ J</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>906</fpage>
          <lpage>12</lpage>
          <issue>2</issue>
          <volume>67</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Tabete</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Nagakura</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Boyle Jr</surname>
              <given-names>ME</given-names>
            </name>
            <name>
              <surname>Duncan</surname>
              <given-names>BW</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B19">
        <mixed-citation>19. Forbess JM, Ashish SS, St. Louis JD, Jaggers JJ, Ungerleider RM. Cryopreservade homografts in the pulmonary position: determinants of durability. Ann Thorac Surg. 2001; 71 (1): 54-60.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Cryopreservade homografts in the pulmonary position: determinants of durability</article-title>
          <source>Ann Thorac Surg</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>54</fpage>
          <lpage>60</lpage>
          <issue>1</issue>
          <volume>71</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Forbess</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Ashish</surname>
              <given-names>SS</given-names>
            </name>
            <name>
              <surname>St. Louis</surname>
              <given-names>JD</given-names>
            </name>
            <name>
              <surname>Jaggers</surname>
              <given-names>JJ</given-names>
            </name>
            <name>
              <surname>Ungerleider</surname>
              <given-names>RM</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B20">
        <mixed-citation>20. Karamlou T, Blackstone EH, Hawkins JA. Can pulmonary conduit dysfunction and failure be reduced in infants and children less than age 2 years at initial implantation ? J Thorac Cardiovasc Surg. 2006; 132 (4): 829-38.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Can pulmonary conduit dysfunction and failure be reduced in infants and children less than age 2 years at initial implantation</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <date>
            <year>2006</year>
          </date>
          <fpage>829</fpage>
          <lpage>38</lpage>
          <issue>4</issue>
          <volume>132</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Karamlou</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Blackstone</surname>
              <given-names>EH</given-names>
            </name>
            <name>
              <surname>Hawkins</surname>
              <given-names>JA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B21">
        <mixed-citation>21. Boethig D, Goerler H , Westhoff-Bleck M, Omo M, Daiber A, Haverich A, et al. Evaluation of 188 consecutive homografts implanted in pulmonary position after 20 years. Eur J Cardiothorac Surg. 2007; 32: 133-42.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Evaluation of 188 consecutive homografts implanted in pulmonary position after 20 years</article-title>
          <source>Eur J Cardiothorac Surg</source>
          <date>
            <year>2007</year>
          </date>
          <fpage>133</fpage>
          <lpage>42</lpage>
          <volume>32</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Boethig</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Goerler</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Westhoff-Bleck</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Omo</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Daiber</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Haverich</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B22">
        <mixed-citation>22. Chan KC, Fyfe DA, Mckay CA. Right ventricular outflow reconstruction with cryopreserved homografts in pediatric patients: intermediate-term follow up with serial echocardiographic assessment. J Am Coll Cardiol. 1994; 24 (2): 483-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Right ventricular outflow reconstruction with cryopreserved homografts in pediatric patients: intermediate-term follow up with serial echocardiographic assessment</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>483</fpage>
          <lpage>9</lpage>
          <issue>2</issue>
          <volume>24</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Chan</surname>
              <given-names>KC</given-names>
            </name>
            <name>
              <surname>Fyfe</surname>
              <given-names>DA</given-names>
            </name>
            <name>
              <surname>Mckay</surname>
              <given-names>CA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B23">
        <mixed-citation>23. Perron J, Moran AM, Gauvreau K, del Nido PJ, Mayer JE Jr, Jonas RA. Valved homograft conduit repair of the right heart in early infancy. Ann Thorac Surg 1999; 68: 542-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Valved homograft conduit repair of the right heart in early infancy</article-title>
          <source>Ann Thorac Surg</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>542</fpage>
          <lpage>8</lpage>
          <volume>68</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Perron</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Moran</surname>
              <given-names>AM</given-names>
            </name>
            <name>
              <surname>Gauvreau</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>del Nido</surname>
              <given-names>PJ</given-names>
            </name>
            <name>
              <surname>Mayer Jr</surname>
              <given-names>JE</given-names>
            </name>
            <name>
              <surname>Jonas</surname>
              <given-names>RA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B24">
        <mixed-citation>24. Razzouk AJ, Williams WG, Cleveland DCColes JE, Rebeyka M, Trusler GA, et al. Surgical connections from ventricle to pulmonary artery. Comparison of four types of valved implants. Circulation. 1992; 86 (5 Suppl II): 154-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Surgical connections from ventricle to pulmonary artery: Comparison of four types of valved implants</article-title>
          <source>Circulation</source>
          <date>
            <year>1992</year>
          </date>
          <fpage>154</fpage>
          <lpage>8</lpage>
          <volume>86</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Razzouk</surname>
              <given-names>AJ</given-names>
            </name>
            <name>
              <surname>Williams</surname>
              <given-names>WG</given-names>
            </name>
            <name>
              <surname>Cleveland DCColes</surname>
              <given-names>JE</given-names>
            </name>
            <name>
              <surname>Rebeyka</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Trusler</surname>
              <given-names>GA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B25">
        <mixed-citation>25. Karamlou T, Ungerleider RM, Alsoufi B, Burch G, Silberbach M, Reller M, et al. Oversizing pulmonary homograft conduits does not significantly decrease allograft failure in children. EurJ Cardiothorac Surg. 2005; 27: 548-53.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Oversizing pulmonary homograft conduits does not significantly decrease allograft failure in children</article-title>
          <source>EurJ Cardiothorac Surg</source>
          <date>
            <year>2005</year>
          </date>
          <fpage>548</fpage>
          <lpage>53</lpage>
          <volume>27</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Karamlou</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Ungerleider</surname>
              <given-names>RM</given-names>
            </name>
            <name>
              <surname>Alsoufi</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Burch</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Silberbach</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Reller</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B26">
        <mixed-citation>26. Christenson JT, Vala D, Sierra J, Beghetti M, Kalangos A. Blood group incompatibility and accelerated homograft fibrocalcifications. J Thorac Cardiovasc Surg. 2004; 127 (1): 242-50.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Blood group incompatibility and accelerated homograft fibrocalcifications</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <date>
            <year>2004</year>
          </date>
          <fpage>242</fpage>
          <lpage>50</lpage>
          <issue>1</issue>
          <volume>127</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Christenson</surname>
              <given-names>JT</given-names>
            </name>
            <name>
              <surname>Vala</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Sierra</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Beghetti</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Kalangos</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Articles</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Dysfunction of the pulmonary homograft used in the reconstruction of the right ventricle exit tract</article-title>
      </title-group>
      <abstract xml:lang="en">
        <p>BACKGROUND: The pulmonary homograft has been used as an option in the correction of congenital cardiopathy with obstruction of the right ventricle exit tract. The long term results, however, are little satisfactory. OBJECTIVE: Identify the risk factors associated to the dysfunction and the pulmonary homograft failure. METHODS: Study with children submitted to the enlargement of the exit tract of the right ventricle with pulmonary homograft. The clinical, surgical, evolutional and morphological aspects of the prosthesis variables were analyzed as risk factors. RESULTS: The final sample of 75 patients with median age at the surgery of 22 months, varying from 1-157 months, presented 13 patients (17.0%) who developed dysfunction of the homograft, characterized by stenosis or severe pulmonary insufficiency. The occurrence time between the homograft implant and the detection of the dysfunction was of 45 &#177; 20 months. When the size of the homograft was smaller than 21 mm and the Z score of the pulmonary valva is lower than zero, or higher than three, the risk factors were considered for the dysfunction occurrence. CONCLUSION: The pulmonary homograft smaller than 21 mm and the inadequate pulmonary valva for the age and weight of the patient are determining factors for the prosthesis dysfunction.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>Transplantation, homologous</kwd>
        <kwd>heart ventricles</kwd>
        <kwd>heart defects</kwd>
        <kwd>congenital</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p><undefined id="tx-body2"/>Dysfunction of the pulmonary homograft used in the reconstruction of the right ventricle exit tract</p>
      <p>
        <bold>Andr&#233;a Weirich Lenzi; M&#225;rcia Olandoski; Wanderley Saviolo Ferreira; Fabio Said Sallum; Nelson Itiro Miyague</bold>
      </p>
      <p> Hospital Pequeno Pr&#237;ncipe, Pontificia Universidade Cat&#243;lica Paran&#225;, Curitiba, PR - Brazil</p>
      <p>Mailing address</p>
      <p>
        <bold>ABSTRACT</bold>
      </p>
      <p><bold>BACKGROUND:</bold> The pulmonary homograft has been used as an option in the correction of congenital cardiopathy with obstruction of the right ventricle exit tract. The long term results, however, are little satisfactory. </p>
      <p><bold>OBJECTIVE:</bold> Identify the risk factors associated to the dysfunction and the pulmonary homograft failure.</p>
      <p><bold>METHODS:</bold> Study with children submitted to the enlargement of the exit tract of the right ventricle with pulmonary homograft. The clinical, surgical, evolutional and morphological aspects of the prosthesis variables were analyzed as risk factors.</p>
      <p><bold>RESULTS:</bold> The final sample of 75 patients with median age at the surgery of 22 months, varying from 1-157 months, presented 13 patients (17.0%) who developed dysfunction of the homograft, characterized by stenosis or severe pulmonary insufficiency. The occurrence time between the homograft implant and the detection of the dysfunction was of 45 &#177; 20 months. When the size of the homograft was smaller than 21 mm and the Z score of the pulmonary valva is lower than zero, or higher than three, the risk factors were considered for the dysfunction occurrence.</p>
      <p><bold>CONCLUSION:</bold> The pulmonary homograft smaller than 21 mm and the inadequate pulmonary valva for the age and weight of the patient are determining factors for the prosthesis dysfunction.</p>
      <p><bold>Key words:</bold> Transplantation, homologous/physiopathology; heart ventricles; heart defects, congenital/surgery.</p>
      <p>
        <bold>Introduction</bold>
      </p>
      <p>The use of homograft in the surgical treatment of the congenital cardiopathies started in the 60's, with Rastelli et al (1964) and Ross and Somerville (1966). In the first years, the high calcification and stenosis rate of the graft caused the search for different combinations of materials for the reconstruction surgeries<sup>1</sup>.</p>
      <p>From the 80's, with the improvement of the techniques of preparation and conservation, the homograft became the chosen material in several services<sup>1</sup>. Despite this, the literature has still been showing the need for surgical changing due to the occurrence of stenosis or prosthesis insufficiency. </p>
      <p>The pediatric cardiac surgery service of <italic>Santa Casa de Curitiba </italic>has been using, since the 90's, the pulmonary or aortic homograft in the correction of the congenital cardiopathies, obtaining good result,</p>
      <p>The reconstruction of the exit path of the right ventricle with pulmonary homograft would have a better evolution in the medium and long term.</p>
      <p>The objective of the study was to evaluate the influence of several risk factors recognized in the literature for the occurrence of dysfunction of the homograft in a sample of operated patients with graft developed in our group.</p>
      <p>
        <bold>Material and methods</bold>
      </p>
      <p>For this study, 90 patients were evaluated, operated in the 1998-2005 period, who used cryopreserved pulmonary type homograft in the reconstruction of the exit pathway of the right ventricle, or in the replacement of a heterograft placed in this position in a previous surgery.</p>
      <p>The cryopreserved pulmonary homograft was provided by the Human Cardiac Valvas Bank of <italic>Santa Casa de Curitiba</italic>.</p>
      <p>The patients using the pulmonary homograft in the reconstruction of the left exit tract, as in the Norwood surgeries and in the interruption of the aortic arch or in the surgeries of cavopulmonary anastomosis were excluded from this study. In addition to those with incomplete data in their records.</p>
      <p>In their records, the data related to gender, cardiopathy type, presence of change in the pulmonary tree, blood type, age in the first visit and at the moment of the surgery, previous surgery, time of outpatient follow-up and result of the tests performed in the institution, such as color echocardiogram doppler and cardiac catheterism were collected.</p>
      <p>The analyzed data of the surgical part were: homograft sizes, donator's blood type, Z value of the pulmonary valva, the maintenance of the homograft integrity, the extracorporeal time and the aortic clamping time. The post-surgery data were: the intercurrences during the stay in the intensive care unit and the occurrence of death in the immediate post-surgery.</p>
      <p>The Z value of the pulmonary valva relates the homograft size in millimeters with the body surface of the patient. The Z value of the pulmonary valva equal to zero means the ideal size of the homograft for the patient's body surface. The negative and positive values mean a less or greater standard deviation from the ideal value,</p>
      <p>The pulmonary homograft integrity can be altered by the surgeon, decreasing the valva ring size, removing one of the cuspids or replacing the cuspids by a monocuspid of homograft, or other material.</p>
      <p>The surgeries were performed by the same surgical team and some patients, before the total correction surgery, required palliative surgeries.</p>
      <p>From the outpatient follow-up, it was analyzed the insufficiency or the pulmonary stenosis, measured by means of echocardiographic tests and classified as mild, moderate and severe. The insufficiency or severe stenosis of the homograft was designated as dysfunction.</p>
      <p>The severe insufficiency was considered as regurgitation that encompasses totally the diameter of the pulmonary ring and with dyastolic reflux in the color Doppler in branches of the pulmonary arteries. The severe stenosis was considered as an instantaneous and maximum systolic gradient in the Doppler, superior to 50 mmHg,</p>
      <p>The existence of reflux with discreet amplitude of the ring was defined as mild pulmonary insufficiency. The moderate pulmonary insufficiency was defined when there was regurgitation of around half of the diameter of the valva ring, with dyastolic reflux in the color Doppler in the trunk of the pulmonary artery. The mild pulmonary stenosis was considered in the presence of the maximum instantaneous pulmonary systolic gradient in the Doppler inferior to 30 mmHg and moderate between 30-50 mmHg,</p>
      <p>It was considered as homograft failure the need to change the pulmonary homograft by surgery due to its dysfunction (insufficiency or severe stenosis).</p>
      <p>For comparing the time curves up to the occurrence of the homograft dysfunction, it was used the Log-rank test. The cases that until the last echocardiographic evaluation did not present homograft dysfunction were considered as censored. In the univariate analysis, the variables gender, age at the time of the surgery, cardiopathy type, homograft size, Z value of the pulmonary valva, blood compatibility, anatomy change of the pulmonary tree, previous surgery, extracorporeal time and aortic clamping time were analyzed.</p>
      <p>For the joint evaluation of factors, a Cox's regression model was adjusted and the relative risk values were estimated, as well as 95.0% confidence intervals. Kaplan-Meier curves were built for presenting the time curves for the homograft dysfunction. Values of p &lt; 0.05 indicated statistical significance. The data were organized in an Excel worksheet and analyzed with the use of the computing software Statistica v.8.0.</p>
      <p>
        <bold>Results</bold>
      </p>
      <p>The records of 92 patients submitted to surgical correction of the cardiopathy with the use of the cryopreserved pulmonary homograft in the right ventricle exit tract were analyzed.</p>
      <p>The average age of the patients in the first visit was 14.3 &#177; 4.2 months. Forty patients received care in the first month of life and 66 during the first year of life. From the patients, 56% were females. </p>
      <p>The cardiopathies are listed in <xref ref-type="table" rid="tab01-body2">Table 1</xref>. The patients with tetralogy of Fallot, who used the pulmonary homograft, were those with agenesia of the pulmonary valva or with hypoplasia of ring and pulmonary trunk.</p>
      <table-wrap id="tab01-body2">
        <graphic xlink:href="1678-4170-abc-96-01-0002-00158-gt01-en.jpg"/></table-wrap>
      <p>The outpatient follow-up of these patients was 106 &#177; 62.7 months, with median of 89 months, varying from 24 months to 272 months.</p>
      <p>The average age of the patients at the moment of the surgery of the cardiopathy correction was 40,3 &#177; 42,3 months, with median of 22 months, varying from 1 month to 157 months. Thirty per cent of the sample (28 cases) were operated before being one year old, with variation in the total correction ages as per the cardiopathy. </p>
      <p>In 8 patients, the exchange of a bovine pericardium tube was performed in a previous surgery by a pulmonary homograft, around 110.5 &#177; 24.3 months after the initial surgery.</p>
      <p>In 46.0% of the patients, the pulmonary tree showed changes as branch stenosis, absence of branch, aneurysmatic pulmonary branches or presence of pulmonary systemic side effects.</p>
      <p>The pulmonary homograft used in the surgeries varied in size from 12 to 26 mm, with average of 21.5 &#177; 3.2 mm and median of 22 mm. The Z value of the pulmonary valva varied from less than one to 5, with average of 2.8 &#177; 1.4 and median of 3. Fifty seven per cent of the homografts had their Z value between 0 and plus 3.</p>
      <p>The integrity of the pulmonary homograft when inserted, varied as per the patient. In 11 cases (12.0% of the sample), there was a change in the pulmonary homograft for better adaptability: 9 cases used a monocuspid of the homograft and two cases a monocuspid of goretex. </p>
      <p>In 47 patients, a hemashield ceiling or bovine pericardium, to make the connection of the right ventricle with the pulmonary homograft. In 30.0% of the patients there was blood compatibility between the donator of the homograft and the receptor. </p>
      <p>In 56.0% of the patients, the extracorporeal time was above 120 minutes, with average of 135 &#177; 44.6 minutes. In 62,0% of the cases, the clamping time of the aorta was kept over 80 minutes, with average of 99.5 &#177; 34.2 minutes.</p>
      <p>There were 17 early deaths, 11 of them by failure of multiple organs and two late deaths.</p>
      <p>The pulmonary homograft dysfunction in the outpatient evaluation was present in 13 patients (17.0% of the sample) and, from these, 5 were submitted to surgical change of the homograft.</p>
      <p>Ten patients presented severe stenosis of the pulmonary homograft with average systolic gradient of 67 &#177; 22 mmHg, varying from 50 mmHg to 127 mmHg, and three patients had severe pulmonary insufficiency.</p>
      <p>For the patients with homograft dysfunction, the surgery time up to the occurrence of the dysfunction was in average 45.4 &#177; 20.3 months with median of 36 months, varying from 7 to 86 months. </p>
      <p>For three years, the survival free from dysfunction was of 90.0%, for 5 years, was of 84.0% and, for 7 years, it was of 80.0%. The survival free from homograft surgical exchange was for 3 years, of 96.0%, for 5 years, was of 94.0% and for 7 years of 93.0%. </p>
      <p>Only the size of the homograft, equal or smaller than 21 mm, was involved in severe dysfunction of the homograft, having a survival free from dysfunction in 5 years of 45.0% for this size and of 80.0% for the homograft over 21 mm (p = 0.009) (<xref ref-type="fig" rid="en_153grf01-body2">Graph 1</xref>).</p>
      <p content-type="asset">
        <fig id="en_153grf01-body2">
          <graphic xlink:href="1678-4170-abc-96-01-0002-00158-gf01-en.jpg"/></fig>
      </p>
      <p>The Z value of the pulmonary valva revealed that, for the measures between zero and plus three, the rate for the dysfunction occurrence in 5 years was of 22.0%, and, for the measures below zero or above plus three, was 65,0% (p = 0.09) (<xref ref-type="fig" rid="en_153grf02-body2">Graph 2</xref>).</p>
      <p content-type="asset">
        <fig id="en_153grf02-body2">
          <graphic xlink:href="1678-4170-abc-96-01-0002-00158-gf02-en.jpg"/></fig>
      </p>
      <p>In Cox's regression, the variable involved in the homograft dysfunction was the size, when the homograft with size inferior or equal to 21 mm had a risk 3,7 times higher than the homograft dysfunction over 21 mm (<xref ref-type="table" rid="tab02-body2">table 2</xref>).</p>
      <table-wrap id="tab02-body2">
        <graphic xlink:href="1678-4170-abc-96-01-0002-00158-gt02-en.jpg"/></table-wrap>
      <p>
        <bold>Discussion</bold>
      </p>
      <p>In the last years, the cardiac surgery service of Santa Casa de Curitiba chose to use the pulmonary homograft for reconstructing the right ventricle exit tract due to its technical advantages and the good clinical and surgical results of the already operated patients<sup>2,3</sup>.</p>
      <p>The option of this service for the use of the pulmonary homograft, in such position, is based on studies that show that the aortic homograft in pulmonary position presents higher index of calcification due to its composition rich in elastin<sup>4-15</sup>.</p>
      <p>From the surgical point of view, the pulmonary homograft is available in small sizes, has higher hemostatic capacity, higher ductility and handling easiness for the surgeon, their branches can be used for enlarging the stenotic areas in the pulmonary arteries, does not need chronic anticoagulation, presents higher resistance to endocarditis and has a potential feasibility for the second repair<sup>5,7,10,11,15-18</sup>.</p>
      <p>In the majority of the cases, the deterioration of the homograft takes place by stenosis due to the calcification<sup>1</sup>. The rate of homograft failure varies as per the study, being in 5 years between 10.0-40.0%<sup>5,14</sup> of the implanted homografts and, in 10 years, between 46.0-65.0%<sup>4,7</sup>.</p>
      <p>Of the risk factors involved in the deterioration of the homograft, the cardiopathy type is one of them. Forbess et al<sup>19</sup>, Bando et al<sup>9</sup> and Dearanie et al<sup>4</sup> found a higher failure rate of the homograft associated to the cardiopathies as <italic>truncus arteriosus</italic>, transposition of the great arteries with pulmonary stenosis and double exit pathway from the right ventricle; however, in this study, there was no homograft durability correlation with the type of cardiopathy.</p>
      <p>In young people, the insertion of the homograft it is considered a risk factor for the conduit failure<sup>4,5,8,9,12,14,15,18-21</sup>. The reasons for this are diverse and, among them, the accelerated growth pattern of the children, the use of homografts of smaller sizes and the immunological response exacerbate in the children. In our study, there was no difference in the durability of the homografts inserted in children below and above one year old. </p>
      <p>One of the most discussed points is the size of the homograft used and its influence in the durability. The pulmonary homograft small in size is associated to a higher dysfunction rate and surgical exchange<sup>4,5,14,15,18,19,21-24</sup>.</p>
      <p>Our study demonstrated that the use of a pulmonary homograft smaller than 21 mm has a higher probability of dysfunction, that is, the homograft below 21 mm has 3.7 times more risk of developing dysfunction than the one above 21 mm. The survival free from dysfunction in 5 years, for a homograft inferior to 21 mm is of 55.0% and, above 21 mm, is of 85.0%.</p>
      <p>Other studies have already related that the homograft size is a risk factor for dysfunction. Bielefeld et al<sup>15</sup> demonstrated that the occurrence of the dysfunction in the homograft above 20 mm is low. Razzouke et al<sup>29</sup> affirms that the homograft above 24 mm has a higher survival free from surgical exchange and Boethige et al<sup>20</sup> shows that the homograft below 20 mm is less durable in children and develops stenosis gradient more quickly.</p>
      <p>The small Z value of the pulmonary valva is also involved in the homograft dysfunction<sup>7,8,20</sup>. The higher dysfunction rate in our study was for a Z value below zero and above plus three, that is, the best results were obtained when the size of the pulmonary valva was between zero and plus three Z value. Thus, some centers, including our Service, has been using a homograft with the biggest number possible for the children, trying to compensate the natural growth of them with a valva of biggest size and decrease the incidence of dysfunction and surgical exchange<sup>7,14,20,21,25,26</sup>.</p>
      <p>In this study, other risk factors for dysfunction of the prosthesis known in the literature such as blood compatibility between donator and receptor, change in the anatomy of the pulmonary tree, cardiac surgery with previous enlargement, use of integral homograft or a replacement of one of its parts, patient sex, extracorporeal time and the age at the surgery did not have influence in the durability of the homograft.</p>
      <p>
        <bold>Conclusion</bold>
      </p>
      <p>The use of pulmonary homograft for the enlargement of the right ventricle exit tract presents good results, with a dysfunction rate of 17.0% of the cases. This study showed lower chance of dysfunction with implant of a pulmonary homograft over 21 mm and a Z value of pulmonary valva between zero and plus three.</p>
      <p>
        <bold>Potential Conflict of Interest</bold>
      </p>
      <p>No potential conflict of interest relevant to this article was reported.</p>
      <p>
        <bold>Sources of Funding</bold>
      </p>
      <p>There were no external funding sources for this study.</p>
      <p>
        <bold>Study Association</bold>
      </p>
      <p>This article is part of the thesis of master submitted by Andr&#233;a Weirich Lenzi, from <italic>Pontif&#237;cia Universidade Cat&#243;lica do Paran&#225;</italic>.</p>
      <p>
        <bold>References</bold>
      </p>
    </body>
  </sub-article>
  <sub-article article-type="translation" id="TRes" xml:lang="es">
    <front-stub>
      <article-categories/>
      <title-group>
        <article-title xml:lang="es">Disfunci&#243;n del homoinjerto pulmonar utilizado en la reconstrucci&#243;n del tracto de salida del ventr&#237;culo derecho</article-title>
      </title-group>
      <abstract xml:lang="es">
        <p>FUNDAMENTO: El homoinjerto pulmonar ha sido utilizado como una opci&#243;n en la correcci&#243;n de cardiopat&#237;a cong&#233;nita con obstrucci&#243;n de la v&#237;a de salida del ventr&#237;culo derecho. Los resultados a largo plazo, mientras tanto, se muestran poco satisfactorios. OBJETIVO: Identificar los factores de riesgo asociados a la disfunci&#243;n y a la falla del homoinjerto pulmonar. M&#201;TODOS: Estudio en ni&#241;os sometidos a la ampliaci&#243;n de la v&#237;a de salida del ventr&#237;culo derecho con homoinjerto pulmonar. Las variables cl&#237;nicas, quir&#250;rgicas, evolutivas y de aspectos morfol&#243;gicos de la pr&#243;tesis fueron analizadas como factores de riesgo. RESULTADOS: La muestra final de 75 pacientes con edad mediana en la cirug&#237;a de 22 meses, variando de 1-157 meses, present&#243; 13 pacientes (17,0%) que desarrollaron disfunci&#243;n del homoinjerto, caracterizado por estenosis o insuficiencia pulmonar grave. El tiempo de ocurrencia entre el implante del homoinjerto y la detecci&#243;n de la disfunci&#243;n fue de 45 &#177; 20 meses. Cuando el tama&#241;o del homoinjerto fue menor de 21 mm y el escore Z de la v&#225;lvula pulmonar fue menor que cero, o mayor que tres, fueron considerados factores de riesgo para la ocurrencia de disfunci&#243;n. CONCLUSI&#211;N: El homoinjerto pulmonar de tama&#241;o menor que 21 mm y la v&#225;lvula pulmonar inadecuada para edad y peso del paciente son factores determinantes para disfunci&#243;n de la pr&#243;tesis.</p>
      </abstract>
      <kwd-group xml:lang="es">
        <kwd>Transplante hom&#243;logo</kwd>
        <kwd>ventr&#237;culos del coraz&#243;n</kwd>
        <kwd>cardiopatias cong&#233;nitas</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>ART&#205;CULO ORIGINAL</p>
      <p> CARDIOLOGIA PEDI&#193;TRICA</p>
      <p>
        <fn id="nota_1-body3">
          <label>
            <bold>Disfunci&#243;n del homoinjerto pulmonar utilizado en la reconstrucci&#243;n del tracto de salida del ventr&#237;culo derecho</bold>
          </label>
          <p>
            <bold>Andr&#233;a Weirich Lenzi; M&#225;rcia Olandoski; Wanderley Saviolo Ferreira; Fabio Said Sallum; Nelson Itiro Miyague</bold>
          </p>
        </fn>
      </p>
      <p>Hospital Pequeno Pr&#237;ncipe, Pontificia Universidade Cat&#243;lica Paran&#225;, Curitiba, PR - Brasil</p>
      <p>Correspondencia</p>
      <p>
        <bold>RESUMEN</bold>
      </p>
      <p><bold>FUNDAMENTO:</bold> El homoinjerto pulmonar ha sido utilizado como una opci&#243;n en la correcci&#243;n de cardiopat&#237;a cong&#233;nita con obstrucci&#243;n de la v&#237;a de salida del ventr&#237;culo derecho. Los resultados a largo plazo, mientras tanto, se muestran poco satisfactorios.</p>
      <p><bold>OBJETIVO:</bold> Identificar los factores de riesgo asociados a la disfunci&#243;n y a la falla del homoinjerto pulmonar.</p>
      <p><bold>M&#201;TODOS:</bold> Estudio en ni&#241;os sometidos a la ampliaci&#243;n de la v&#237;a de salida del ventr&#237;culo derecho con homoinjerto pulmonar. Las variables cl&#237;nicas, quir&#250;rgicas, evolutivas y de aspectos morfol&#243;gicos de la pr&#243;tesis fueron analizadas como factores de riesgo.</p>
      <p><bold>RESULTADOS:</bold> La muestra final de 75 pacientes con edad mediana en la cirug&#237;a de 22 meses, variando de 1-157 meses, present&#243; 13 pacientes (17,0%) que desarrollaron disfunci&#243;n del homoinjerto, caracterizado por estenosis o insuficiencia pulmonar grave. El tiempo de ocurrencia entre el implante del homoinjerto y la detecci&#243;n de la disfunci&#243;n fue de 45 &#177; 20 meses. Cuando el tama&#241;o del homoinjerto fue menor de 21 mm y el escore Z de la v&#225;lvula pulmonar fue menor que cero, o mayor que tres, fueron considerados factores de riesgo para la ocurrencia de disfunci&#243;n.</p>
      <p><bold>CONCLUSI&#211;N:</bold> El homoinjerto pulmonar de tama&#241;o menor que 21 mm y la v&#225;lvula pulmonar inadecuada para edad y peso del paciente son factores determinantes para disfunci&#243;n de la pr&#243;tesis.</p>
      <p><bold>Palabras clave:</bold> Transplante hom&#243;logo/fisiopatolog&#237;a, ventr&#237;culos del coraz&#243;n, cardiopatias cong&#233;nitas/cirug&#237;a.</p>
      <p>
        <bold>Introducci&#243;n</bold>
      </p>
      <p>El uso del homoinjerto en el tratamiento quir&#250;rgico de las cardiopat&#237;as cong&#233;nitas tuvo su inicio en la d&#233;cada de 60, con Rastelli et al (1964) y Ross y Somerville (1966). En los a&#241;os iniciales, la alta tasa de calcificaci&#243;n y estenosis del injerto provoc&#243; la b&#250;squeda de diferentes combinaciones de materiales para las cirug&#237;as de reconstrucci&#243;n<sup>1</sup>.</p>
      <p>A partir de la d&#233;cada de 80, con el mejoramiento de las t&#233;cnicas de preparaci&#243;n y conservaci&#243;n, el homoinjerto se volvi&#243; el material de elecci&#243;n en varios servicios<sup>1</sup>. A pesar de eso, la literatura aun ha mostrado la necesidad de intercambio quir&#250;rgico por la ocurrencia de estenosis o insuficiencia de la pr&#243;tesis. </p>
      <p>El servicio de cirug&#237;a card&#237;aca pedi&#225;trica de la Santa Casa de Curitiba utiliza, desde la d&#233;cada de 90, el homoinjerto pulmonar o a&#243;rtico en la correcci&#243;n de cardiopat&#237;as cong&#233;nitas, obteniendo buen resultado. </p>
      <p>La reconstrucci&#243;n de la v&#237;a de salida del ventr&#237;culo derecho con homoinjerto pulmonar tendr&#237;a mejor evoluci&#243;n en medio y largo plazo.</p>
      <p>El objetivo del estudio fue evaluar la influencia de diversos factores de riesgo reconocidos en la literatura para la ocurrencia de disfunci&#243;n del homoinjerto en una muestra de pacientes operados con injerto desarrollado en nuestro medio.</p>
      <p>
        <bold>Material y m&#233;todos</bold>
      </p>
      <p>Para este estudio, se evalu&#243; 92 pacientes, operados en el per&#237;odo de 1998-2005, que utilizaron homoinjerto del tipo pulmonar criopreservado en la reconstrucci&#243;n de la v&#237;a de salida del ventr&#237;culo derecho, o en la sustituci&#243;n de un heteroinjerto colocado en esta posici&#243;n en cirug&#237;a previa. </p>
      <p>El homoinjerto pulmonar criopreservado fue provisto por el Banco de V&#225;lvulas Card&#237;acas Humanas de la Santa Casa de Curitiba.</p>
      <p>Fueron excluidos de este estudio los pacientes que usaron el homoinjerto pulmonar en la reconstrucci&#243;n del tracto de salida izquierdo, como en las cirug&#237;as de Norwood y en la interrupci&#243;n del arco a&#243;rtico o en las cirug&#237;as de anastomosis cavopulmonar. Adem&#225;s de aquellos con datos incompletos en sus historias cl&#237;nicas.</p>
      <p>En sus historias cl&#237;nicas, fueron colectados los datos referentes al sexo, tipo de cardiopat&#237;a, presencia de alteraci&#243;n del &#225;rbol pulmonar, tipo sangu&#237;neo, edad en la primera consulta y en el momento de la cirug&#237;a, cirug&#237;a previa, el tiempo de control ambulatorio y resultado de ex&#225;menes realizados en la instituci&#243;n, como ecocardiograma Doppler color y cateterismo card&#237;aco. </p>
      <p>Los datos de la parte quir&#250;rgica analizados fueron: tama&#241;os de homoinjerto, tipo sangu&#237;neo donante, valor Z de la v&#225;lvula pulmonar, la manutenci&#243;n de la integridad del homoinjerto, el tiempo de extracorp&#243;rea y el tiempo de clampeo a&#243;rtico. Los datos del postoperatorio fueron: las intercurrencias durante la permanencia en la unidad de terapia intensiva y la ocurrencia de &#243;bito en el post operatorio inmediato. </p>
      <p>El valor Z de la v&#225;lvula pulmonar relaciona el tama&#241;o del homoinjerto en mil&#237;metros con la superficie corporal del paciente. El valor Z de la v&#225;lvula pulmonar igual a cero significa el tama&#241;o ideal del homoinjerto para la superficie corporal del paciente. Los valores negativos y positivos significan una desviaci&#243;n-est&#225;ndar para m&#225;s o para menos del valor ideal. </p>
      <p>La integridad del homoinjerto pulmonar puede ser alterada por el cirujano, disminuy&#233;ndo el tama&#241;o del anillo valvular, retir&#225;ndo una de las c&#250;spides o sustituy&#233;ndo las c&#250;spides por una monoc&#250;spide de homoinjerto, o otro material.</p>
      <p>Las cirug&#237;as fueron realizadas por el mismo equipo quir&#250;rgico, y algunos pacientes, antes de la cirug&#237;a de correcci&#243;n total, necesitaron cirug&#237;as paliativas.</p>
      <p>Del control ambulatorio, se analiz&#243; la insuficiencia o la estenosis pulmonar, medidas por medio de ex&#225;menes ecocardiogr&#225;ficos y clasificados en leve, moderada y grave. La insuficiencia o estenosis grave del homoinjerto fue designada como disfunci&#243;n.</p>
      <p>La insuficiencia grave fue considerada como regurgitaci&#243;n que abarca totalmente el di&#225;metro del anillo pulmonar y con reflujo diast&#243;lico en el Doppler color en ramas de las arterias pulmonares. La estenosis grave fue considerada como un gradiente sist&#243;lico instant&#225;neo y m&#225;ximo en el Doppler mayor que 50 mmHg. </p>
      <p>La existencia de reflujo de discreta inclusi&#243;n del anillo se defini&#243; como insuficiencia pulmonar leve. La insuficiencia pulmonar moderada fue definida cuando hab&#237;a regurgitaci&#243;n de cerca de mitad del di&#225;metro del anillo valvular con reflujo diast&#243;lico en el Doppler color en tronco de la arteria pulmonar. La estenosis pulmonar leve fue considerada en la presencia de gradiente sist&#243;lico pulmonar instant&#225;neo m&#225;ximo en el Doppler menor que 30 mmHg y moderada entre 30-50 mmHg.</p>
      <p>Se consider&#243; como falla del homoinjerto la necesidad de intercambio del homoinjerto pulmonar por v&#237;a quir&#250;rgica debido a su disfunci&#243;n (insuficiencia o estenosis severa). </p>
      <p>Para la comparaci&#243;n de las curvas de tiempo hasta la ocurrencia de disfunci&#243;n de homoinjerto, fue usado el test de <italic>Log-rank</italic>. Los casos que hasta la &#250;ltima evaluaci&#243;n ecocardiogr&#225;fica no hab&#237;an presentado disfunci&#243;n del homoinjerto fueron considerados censurados. En el an&#225;lisis univariado, fueron analizadas las variables sexo, edad a la &#233;poca de la cirug&#237;a, tipo de cardiopat&#237;a, tama&#241;o de homoinjerto, valor Z de la v&#225;lvula pulmonar, compatibilidad sangu&#237;nea, alteraci&#243;n de la anatom&#237;a del &#225;rbol pulmonar, cirug&#237;a previa, tiempo de extracorp&#243;rea y tiempo de clampeo a&#243;rtico.</p>
      <p>Para evaluaci&#243;n conjunta de factores, fue ajustado un modelo de Regresi&#243;n de Cox y estimados los valores de riesgo relativo e intervalos de 95,0% de confianza. Curvas de Kaplan-Meier fueron construidas para presentar las curvas de tiempo para la disfunci&#243;n de homoinjerto. Valores de p &lt; 0,05 indicaron significaci&#243;n estad&#237;stica. Los datos fueron organizados en planilla Excel y analizados con el uso del programa computacional <italic>Statistica</italic> v.8.0.</p>
      <p>
        <bold>Resultados</bold>
      </p>
      <p>Se analizaron los historias cl&#237;nicas de los 92 pacientes sometidos a correcci&#243;n quir&#250;rgica de la cardiopat&#237;a con utilizaci&#243;n de homoinjerto pulmonar criopreservado en el tracto de salida del ventr&#237;culo derecho.</p>
      <p>La edad media de los pacientes en la primera consulta fue de 14,3 &#177; 4,2 meses. Cuarenta pacientes fueron atendidos en el primer mes de vida y 66 durante el primer a&#241;o de vida. De los pacientes, 56% eran del sexo femenino. </p>
      <p>Las cardiopat&#237;as est&#225;n relacionadas en la <xref ref-type="table" rid="tab1-body3">Tabla 1</xref>. Los pacientes con tetralog&#237;a de Fallot, que utilizaron el homoinjerto pulmonar, fueron los que ten&#237;an agenesia de la v&#225;lvula pulmonar o con hipoplasia de anillo y tronco pulmonar.</p>
      <table-wrap id="tab1-body3">
        <graphic xlink:href="1678-4170-abc-96-01-0002-00158-gt01-es.jpg"/></table-wrap>
      <p>El tiempo de control ambulatorio de esos pacientes fue de 106 &#177; 62,7 meses, con mediana de 89 meses, variando de 24 meses a 272 meses.</p>
      <p>La edad media de los pacientes en el momento de la cirug&#237;a de correcci&#243;n de la cardiopat&#237;a fue de 40,3 &#177; 42,3 meses, con mediana de 22 meses, variando de 1 mes a 157 meses. Treinta por ciento de la muestra (28 casos) operaron abajo de un a&#241;o de edad, habiendo variaci&#243;n en las edades de correcci&#243;n total seg&#250;n la cardiopat&#237;a.</p>
      <p>En 8 pacientes, se realiz&#243; el intercambio de un tubo de pericardio bovino colocado en cirug&#237;a previa por un homoinjerto pulmonar, en media 110,5 &#177; 24,3 meses despu&#233;s de la cirug&#237;a inicial.</p>
      <p>En 46,0% de los pacientes, el &#225;rbol pulmonar mostraba alteraciones como estenosis de rama, ausencia de rama, ramas pulmonares aneurism&#225;ticos o presencia de efectos colaterales sist&#233;micos pulmonares.</p>
      <p>El homoinjerto pulmonar utilizado en las cirug&#237;as vari&#243; su tama&#241;o de 12 a 26 mm, con media de 21,5 &#177; 3,2 mm y mediana de 22 mm. El valor Z de la v&#225;lvula pulmonar vari&#243; de menos uno a 5, con media de 2,8 &#177; 1,4 y mediana de 3. Cincuenta y siete por ciento de los homoinjertos tuvieron su valor <italic>Z </italic>entre 0 y m&#225;s 3.</p>
      <p> La integridad del homoinjerto pulmonar en la colocaci&#243;n vari&#243; seg&#250;n el paciente. En 11 casos (12,0% de la muestra), hubo alteraci&#243;n del homoinjerto pulmonar para su mejor adaptabilidad: 9 casos utilizaron una monoc&#250;spide del homoinjerto y dos casos una monoc&#250;spide de goretex. </p>
      <p>En 47 pacientes, se utiliz&#243; un techo, de hemashield o pericardio bovino, para hacer la ligaz&#243;n del ventr&#237;culo derecho con el homoinjerto pulmonar. En 30,0% de los pacientes, hubo compatibilidad sangu&#237;nea entre el donante del homoinjerto y el receptor. </p>
      <p>En 56,0% de los pacientes, el tiempo de extracorp&#243;rea estuvo encima de los 120 minutos, con media de 135 &#177; 44,6 minutos. En 62,0% de los casos, el tiempo clampeo de aorta se mantuvo encima de 80 minutos, con media de 99,5 &#177; 34,2 minutos.</p>
      <p>Hubo 17 casos de &#243;bito precoz, 11 de estos por falla de m&#250;ltiplos &#243;rganos y de los &#243;bitos tard&#237;os. </p>
      <p>La disfunci&#243;n del homoinjerto pulmonar en la evaluaci&#243;n ambulatoria se present&#243; en 13 pacientes (17,0% de la muestra) y, de estos, 5 fueron sometidos a intercambio quir&#250;rgico del homoinjerto. </p>
      <p>Diez pacientes presentaban estenosis grave del homoinjerto pulmonar con gradiente sist&#243;lico medio 67 &#177; 22 mmHg, variando de 50 mmhg a 127 mmHg, y tres pacientes ten&#237;an insuficiencia pulmonar grave.</p>
      <p>Para los pacientes con disfunci&#243;n del homoinjerto, el tiempo de la cirug&#237;a hasta la ocurrencia de la disfunci&#243;n fue en media 45,4 &#177; 20,3 meses con mediana de 36 meses, variando de 7 a 86 meses. </p>
      <p>Para tres a&#241;os, la sobrevida libre de disfunci&#243;n fue de 90,0%, para 5 a&#241;os, fue de 84,0% y, para 7 a&#241;os, fue de 80,0%. La sobrevida libre de intercambio quir&#250;rgico del homoinjerto fue, para 3 a&#241;os, de 96,0%, para 5 a&#241;os, fue de 94,0% y para 7 a&#241;os de 93,0%. </p>
      <p>Apenas el tama&#241;o del homoinjerto, igual o menor que 21 mm, estuvo implicado en la disfunci&#243;n grave del homoinjerto, teniendo una sobrevida libre de disfunci&#243;n en 5 a&#241;os de 45,0% para este tama&#241;o, y de 80,0% para los homoinjertos encima de 21 mm (p = 0,009) (<xref ref-type="fig" rid="es_a02gra01-body3">Gr&#225;fico 1</xref>).</p>
      <p content-type="asset">
        <fig id="es_a02gra01-body3">
          <graphic xlink:href="1678-4170-abc-96-01-0002-00158-gf01-es.jpg"/></fig>
      </p>
      <p>El valor Z de la v&#225;lvula pulmonar revel&#243; que, para las medidas entre cero y m&#225;s tres, la tasa para ocurrencia de disfunci&#243;n en 5 a&#241;os fue de 22,0%, y, para las medidas abajo de cero o encima de m&#225;s tres, fue 65,0% (p = 0,09) (<xref ref-type="fig" rid="es_a02gra02-body3">Gr&#225;fico 2</xref>).</p>
      <p content-type="asset">
        <fig id="es_a02gra02-body3">
          <graphic xlink:href="1678-4170-abc-96-01-0002-00158-gf02-es.jpg"/></fig>
      </p>
      <p>En la regresi&#243;n Cox, la variable implicada en la disfunci&#243;n del homoinjerto fue el tama&#241;o, donde el homoinjerto con tama&#241;o menor o igual a 21 mm tuvo riesgo 3,7 veces mayor que la disfunci&#243;n del homoinjerto encima 21 mm (<xref ref-type="table" rid="tab2-body3">Tabla 2</xref>).</p>
      <table-wrap id="tab2-body3">
        <graphic xlink:href="1678-4170-abc-96-01-0002-00158-gt02-es.jpg"/></table-wrap>
      <p>
        <bold>Discusi&#243;n</bold>
      </p>
      <p>En los &#250;ltimos a&#241;os, el servicio de cirug&#237;a card&#237;aca del Hospital Pequeno Pr&#237;ncipe de Curitiba opt&#243; por el empleo del homoinjerto pulmonar para reconstrucci&#243;n del tracto de salida del ventr&#237;culo derecho debido a sus ventajas t&#233;cnicas y a los buenos resultados cl&#237;nicos y quir&#250;rgicos de pacientes ya operados<sup>2,3</sup>.</p>
      <p>La opci&#243;n de ese servicio por el uso del homoinjerto pulmonar, en tal posici&#243;n, est&#225; basada en estudios que muestran que el homoinjerto a&#243;rtico en posici&#243;n pulmonar presenta mayor &#237;ndice de calcificaci&#243;n debido a su composici&#243;n rica en elastina<sup>4-15</sup>.</p>
      <p>Del punto de vista quir&#250;rgico, el homoinjerto pulmonar est&#225; disponible en tama&#241;os peque&#241;os, tiene mayor capacidad hemost&#225;tica, mayor maleabilidad y facilidad de manejo para el cirujano, sus ramas pueden ser usados para ampliaci&#243;n de &#225;reas esten&#243;ticas en las arterias pulmonares, no precisa anticoagulaci&#243;n cr&#243;nica, presenta mayor resistencia a la endocarditis y posee una potencial viabilidad para la segunda reparaci&#243;n<sup>5,7,10,11,15-18</sup>.</p>
      <p>En la mayor&#237;a de los casos, el deterioro del homoinjerto acontece por estenosis debido a la calcificaci&#243;n<sup>1</sup>. La tasa de falla del homoinjerto var&#237;a seg&#250;n el estudio, siendo, en 5 a&#241;os, entre 10,0-40,0%<sup>5,14</sup> de los homoinjertos implantados y, en 10 a&#241;os, entre 46,0-65,0%<sup>4,7</sup>.</p>
      <p>De los factores de riesgo implicados en el deterioro del homoinjerto, el tipo de cardiopat&#237;a es uno de ellos. Forbess et al<sup>19</sup>, Bando et al<sup>9</sup> y Dearanie et al<sup>4</sup> encontraron una mayor tasa de falla del homoinjerto asociado a cardiopat&#237;as como <italic>truncus arteriosus</italic>, transposici&#243;n de las grandes arterias con estenosis pulmonar y doble v&#237;a de salida del ventr&#237;culo derecho, mientras tanto, en este estudio, no hubo correlaci&#243;n de la durabilidad del homoinjerto con el tipo de cardiopat&#237;a.</p>
      <p>En la edad joven, la colocaci&#243;n del homoinjerto es considerada un factor de riesgo para la falla del conducto<sup>4,5,8,9,12,14,15,18-21</sup>. Los motivos para esto son diversos, y, entre ellos, est&#225;n el est&#225;ndar crecimiento acelerado del ni&#241;o, la utilizaci&#243;n de homoinjertos de tama&#241;os menores y la respuesta inmunol&#243;gica exacerbada en el ni&#241;o. En nuestro estudio, no hubo diferencia en la durabilidad de los homoinjertos colocados en ni&#241;os abajo de un a&#241;o y encima de un a&#241;o de edad. </p>
      <p>Uno de los puntos m&#225;s discutidos es el tama&#241;o del homoinjerto utilizado y su influencia en la durabilidad. El homoinjerto pulmonar de tama&#241;o peque&#241;o es asociado a una mayor tasa de disfunci&#243;n y de intercambio quir&#250;rgico<sup>4,5,14,15,18,19,21-24</sup>.</p>
      <p>Nuestro trabajo demostr&#243; que el uso de homoinjerto pulmonar menor de 21 mm tiene una mayor probabilidad de disfunci&#243;n, o sea, el homoinjerto abajo de 21 mm tiene 3,7 veces m&#225;s riesgo de desarrollar disfunci&#243;n que el de encima de 21 mm. La sobrevida libre de disfunci&#243;n, en 5 a&#241;os, para un homoinjerto menor de 21 mm es de 55,0% y, encima de 21 mm, es de 85,0%.</p>
      <p>Otros estudios ya hab&#237;an relatado que el tama&#241;o del homoinjerto es un factor de riesgo para disfunci&#243;n. Bielefeld et al<sup>15</sup> demostraron que la ocurrencia de disfunci&#243;n en homoinjerto encima de 20 mm es baja. Razzouke et al<sup>24</sup> afirman que homoinjerto encima de 24 mm tiene sobrevida libre de intercambio quir&#250;rgico mayor y Boethige et al<sup>21</sup> muestran que el homoinjerto abajo de 20 mm es menos durable en ni&#241;os y desarrolla gradiente de estenosis m&#225;s r&#225;pidamente.</p>
      <p>El valor Z peque&#241;o de la v&#225;lvula pulmonar tambi&#233;n es implicado en la disfunci&#243;n del homoijerto<sup>7,8,20</sup>. La tasa mayor de disfunci&#243;n en nuestro estudio fue para un valor Z abajo de cero y encima de m&#225;s tres, en fin, los mejores resultados fueron obtenidos cuando el tama&#241;o de la v&#225;lvula pulmonar qued&#243; entre el valor Z cero y m&#225;s tres. As&#237; siendo, algunos centros, incluyendo nuestro Servicio, han utilizado un homoinjerto de mayor n&#250;mero posible para el ni&#241;o, en la tentativa de compensar su crecimiento natural con una v&#225;lvula de mayor tama&#241;o y disminuir la incidencia de disfunci&#243;n y intercambio quir&#250;rgico<sup>7,14,20,21,25,26</sup>.</p>
      <p>En este trabajo, otros factores de riesgo para disfunci&#243;n de la pr&#243;tesis, conocidos en la literatura como compatibilidad sangu&#237;nea entre donante y receptor, alteraci&#243;n de la anatom&#237;a del &#225;rbol pulmonar, cirug&#237;a card&#237;aca con ampliaci&#243;n previa, utilizaci&#243;n del homoinjerto &#237;ntegro o la sustituci&#243;n de una de sus partes, sexo del paciente, tiempo de extracorp&#243;rea y la edad a la cirug&#237;a no tuvieron influencia en la durabilidad del homoinjerto.</p>
      <p>
        <bold>Conclusi&#243;n</bold>
      </p>
      <p>La utilizaci&#243;n del homoinjerto pulmonar para ampliaci&#243;n del tracto de salida del ventr&#237;culo derecho presenta buenos resultados, con una tasa de disfunci&#243;n de 17,0% de los casos. Este estudio mostr&#243; menor posibilidad de disfunci&#243;n con implante de un homoinjerto pulmonar encima de 21 mm y un valor Z de la v&#225;lvula pulmonar comprendido entre cero y m&#225;s tres.</p>
      <p>
        <bold>Potencial Conflicto de Intereses</bold>
      </p>
      <p>Declaro no haber conflicto de intereses pertinentes.</p>
      <p>
        <bold>Fuentes de Financiamiento</bold>
      </p>
      <p>El presente estudio no tuvo fuentes de financiamiento externas.</p>
      <p>
        <bold>Vinculaci&#243;n Acad&#233;mica</bold>
      </p>
      <p>Este art&#237;culo es parte de tesis de maestr&#237;a de Andr&#233;a Weirich Lenzi por la Pontif&#237;cia Universidade Cat&#243;lica de Paran&#225;.</p>
      <p>
        <bold>Referencias</bold>
      </p>
    </body>
  </sub-article>
</article>
