<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">wzB9bvPGt3G4gNcCJJWRwyB</article-id>
      <article-id pub-id-type="other">00017</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2010001500017</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(10)09500517</article-id>
      <article-id pub-id-type="doi">10.1590/S0066-782X2010001500017</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Carta ao Editor</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>A seguran&#231;a do teste de caminhada de seis minutos</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Guimar&#227;es</surname>
            <given-names>Guilherme Veiga</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Carvalho</surname>
            <given-names>Vitor Oliveira</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Belli</surname>
            <given-names>Juliana Fernanda</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <addr-line>
          <named-content content-type="city">S&#227;o Paulo</named-content>
          <named-content content-type="state">S&#227;o Paulo</named-content>
        </addr-line>
        <institution content-type="orgname">Universidade de S&#227;o Paulo</institution>
        <institution content-type="orgdiv1">Faculdade de Medicina </institution>
        <institution content-type="orgdiv2">Hospital das Cl&#237;nicas</institution>
        <country country="BR">Brazil</country>
      </aff>
      <aff id="aff02">
        <addr-line>
          <named-content content-type="city">S&#227;o Paulo</named-content>
          <named-content content-type="state">S&#227;o Paulo</named-content>
        </addr-line>
        <institution content-type="orgname">Universidade de S&#227;o Paulo</institution>
        <country country="BR">Brazil</country>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>10</month>
        <year>2010</year>
      </pub-date>
      <volume>95</volume>
      <issue>5</issue>
      <fpage>671</fpage>
      <lpage>671</lpage>
      <history>
        <date date-type="received">
          <day>27</day>
          <month>08</month>
          <year>2009</year>
        </date>
        <date date-type="accepted">
          <day>09</day>
          <month>09</month>
          <year>2009</year>
        </date>
        <date date-type="rev-recd">
          <day>02</day>
          <month>09</month>
          <year>2009</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <kwd-group xml:lang="pt" kwd-group-type="author-generated">
        <kwd>Seguran&#231;a</kwd>
        <kwd>caminhada</kwd>
        <kwd>exerc&#237;cio</kwd>
      </kwd-group>
      <pub-date publication-format="electronic" date-type="pub">
        <day>13</day>
        <month>04</month>
        <year>2011</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>
      <bold>CARTA AO EDITOR</bold>
    </p>
    <p>
      <bold>A seguran&#231;a do teste de caminhada de seis minutos</bold>
    </p>
    <p>
      <bold>Guilherme Veiga Guimar&#227;es<sup>I,II</sup>; Vitor Oliveira Carvalho<sup>I,II</sup>; Juliana Fernanda Belli<sup>I,II</sup></bold>
    </p>
    <p><sup>I</sup>Laborat&#243;rio de Insufici&#234;ncia Card&#237;aca e Transplante do Instituto do Cora&#231;&#227;o do Hospital das Cl&#237;nicas da Faculdade de Medicina da USP (InCor HC-FMUSP), S&#227;o Paulo, SP - Brasil </p>
    <p><sup>II</sup>Laborat&#243;rio de Atividade F&#237;sica e Sa&#250;de (LAtiS/InCor), S&#227;o Paulo, SP - Brasil</p>
    <p>
      <xref ref-type="corresp" rid="end">Correspond&#234;ncia</xref>
    </p>
    <p><bold>Palavras-chave:</bold> Seguran&#231;a, caminhada, exerc&#237;cio.</p>
    <p>
      <bold>Senhor Editor,</bold>
    </p>
    <p>Cipriano e cols.<sup>1</sup> estudaram a seguran&#231;a do teste de caminhada de 6 minutos (TC6) em pacientes em pr&#233;-transplante card&#237;aco. Baseado no comportamento cl&#237;nico e eletrocardiogr&#225;fico, tal estudo mostrou que o TC6 foi seguro. Dois pacientes apresentaram arritmia pr&#233;-TC6 e n&#227;o pioraram ante o esfor&#231;o, 4 tiveram eleva&#231;&#227;o significativa nos n&#237;veis de lactato, e tr&#234;s interromperam o exame por dispneia. No entanto, o teste de caminhada de 6 minutos pode ser considerado de alta intensidade para alguns pacientes com insufici&#234;ncia card&#237;aca.</p>
    <p>A discuss&#227;o acerca da natureza subm&#225;xima do TC6 n&#227;o &#233; recente, bem como sua seguran&#231;a em pacientes com insufici&#234;ncia card&#237;aca<sup><italic>2</italic></sup>. Guimar&#227;es e cols.<sup>2</sup> observaram que no teste ergoespirom&#233;trico TC6, utilizando escala de Borg entre 11 e 13, <italic>versus</italic> o TC6 utilizando as recomenda&#231;&#245;es usuais, a m&#233;dia da dist&#226;ncia percorrida foi de 332 <italic>versus</italic> 470 m, VO<sub>2</sub> de 60% <italic>versus</italic> 90% do VO<sub>2</sub> pico, frequ&#234;ncia card&#237;aca de 77% <italic>versus</italic> 89% da FCmax, e raz&#227;o de troca respirat&#243;ria de 0,90 <italic>versus</italic> 1,06.</p>
    <p>Na compara&#231;&#227;o entre os testes, observou-se diferen&#231;a estat&#237;stica entre as avalia&#231;&#245;es. Dessa forma, sendo o objetivo do TC6 um poss&#237;vel reflexo da atividade di&#225;ria neste grupo de pacientes, o uso da escala de Borg, entre relativamente f&#225;cil e ligeiramente cansativo, durante TC6 parece ser mais adequado e garante a seguran&#231;a para tal finalidade<sup>3,4</sup>, al&#233;m de ser reprodut&#237;vel e assegurar sua natureza subm&#225;xima<sup>22,5</sup>.</p>
    <p>
      <bold>Resposta</bold>
    </p>
    <p>O artigo de Guimar&#227;es e cols.<sup>2</sup>, forneceu informa&#231;&#245;es cient&#237;ficas importantes a respeito do teste de caminhada de 6 Minutos, especialmente quanto a compara&#231;&#227;o com o teste "controlado" e teste cardiopulmonar m&#225;ximo. Acreditamos que nosso artigo<sup>1</sup> tenha fornecido informa&#231;&#245;es adicionais e cientificamente relevantes quanto &#224; intensidade e seguran&#231;a, uma vez que utilizou pioneiramente as medidas de lactato e eletrocardiografia <italic>online</italic> por telemetria, respectivamente, durante o teste de caminhada de 6 minutos. O estudo de Belardinelli<sup>3</sup> foi citado como refer&#234;ncia em nosso artigo (refer&#234;ncia n&#186; 26), no entanto, descreveu a partir de um estudo de revis&#227;o, a ocorr&#234;ncia de arritmias durante um programa de exerc&#237;cio para condicionamento f&#237;sico, e n&#227;o durante um teste de esfor&#231;o para avalia&#231;&#227;o cardiorrespirat&#243;ria, como teste de caminhado de 6 minutos. A aplica&#231;&#227;o do referido teste com o controle da intensidade (Borg) e a reprodutibilidade, n&#227;o foram objetivos de nosso estudo<sup>4,5</sup>.</p>
    <p>
      <fn id="end" fn-type="corresp">
        <label>
          <bold>Correspond&#234;ncia:</bold>
        </label>
        <p> Guilherme Veiga Guimar&#227;es </p>
        <p> Rua Dr. Baeta Neves, 98 - Pinheiros </p>
        <p> 05444-050 - S&#227;o Paulo, SP - Brasil </p>
        <p> E-mail: </p>
        <p>
          <email xlink:href="gvguima@usp.br">gvguima@usp.br</email>
        </p>
      </fn>
    </p>
    <p>Artigo recebido em 27/08/09; revisado recebido em 02/09/09; aceito em 09/09/09.</p>
  </body>
  <back>
    <ref-list>
      <ref id="B1">
        <mixed-citation>1. Cipriano Jr G, Yuri D, Bernardelli GF, Mair V, Buffolo E, Branco JNR. Avalia&#231;&#227;o da seguran&#231;a do teste de caminhada dos 6 minutos em pacientes no pr&#233;-transplante card&#237;aco. Arq Bras Cardiol. 2009; 92 (4): 312-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Avalia&#231;&#227;o da seguran&#231;a do teste de caminhada dos 6 minutos em pacientes no pr&#233;-transplante card&#237;aco</article-title>
          <source>Arq Bras Cardiol</source>
          <date>
            <year>2009</year>
          </date>
          <fpage>312</fpage>
          <lpage>9</lpage>
          <issue>4</issue>
          <volume>92</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Cipriano Jr</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Yuri</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Bernardelli</surname>
              <given-names>GF</given-names>
            </name>
            <name>
              <surname>Mair</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Buffolo</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Branco</surname>
              <given-names>JNR.</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Guimar&#227;es GV, Bellotti G, Bacal F, Mocelin A, Bocchi EA. Can the cardiopulmonary 6-minute walk test reproduce the usual activities of patients with heart failure? Arq Bras Cardiol. 2002; 78 (6): 557-60.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Can the cardiopulmonary 6-minute walk test reproduce the usual activities of patients with heart failure?</article-title>
          <source>Arq Bras Cardiol</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>557</fpage>
          <lpage>60</lpage>
          <issue>6</issue>
          <volume>78</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Guimar&#227;es</surname>
              <given-names>GV</given-names>
            </name>
            <name>
              <surname>Bellotti</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Bacal</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Mocelin</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Bocchi</surname>
              <given-names>EA.</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. Belardinelli R. Arrhythmias during acute and chronic exercise in chronic heart failure. Int J Cardiol. 2003; 90 (2-3): 213-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Arrhythmias during acute and chronic exercise in chronic heart failure</article-title>
          <source>Int J Cardiol</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>213</fpage>
          <lpage>8</lpage>
          <issue>2-3</issue>
          <volume>90</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Belardinelli</surname>
              <given-names>R.</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Carvalho VO, Bocchi EA, Guimar&#227;es GV. The Borg scale as an important tool of self-monitoring and self-regulation of exercise prescription in heart failure patients during hydrotherapy: a randomized blinded controlled trial. Circ J. 2009; 73 (10): 1871-6.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>The Borg scale as an important tool of self-monitoring and self-regulation of exercise prescription in heart failure patients during hydrotherapy: a randomized blinded controlled trial</article-title>
          <source>Circ J</source>
          <date>
            <year>2009</year>
          </date>
          <fpage>1871</fpage>
          <lpage>6</lpage>
          <issue>10</issue>
          <volume>73</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Carvalho</surname>
              <given-names>VO</given-names>
            </name>
            <name>
              <surname>Bocchi</surname>
              <given-names>EA</given-names>
            </name>
            <name>
              <surname>Guimar&#227;es</surname>
              <given-names>GV.</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. Guimar&#227;es GV, Carvalho VO, Bocchi EA. Reproducibility of the self-controlled six-minute walking test in heart failure patients. Clinics. 2008; 63 (2): 201-6.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Reproducibility of the self-controlled six-minute walking test in heart failure patients</article-title>
          <source>Clinics</source>
          <date>
            <year>2008</year>
          </date>
          <fpage>201</fpage>
          <lpage>6</lpage>
          <issue>2</issue>
          <volume>63</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Guimar&#227;es</surname>
              <given-names>GV</given-names>
            </name>
            <name>
              <surname>Carvalho</surname>
              <given-names>VO</given-names>
            </name>
            <name>
              <surname>Bocchi</surname>
              <given-names>EA.</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="TRes" xml:lang="es">
    <front-stub>
      <article-categories/>
      <title-group>
        <article-title xml:lang="es">La seguridad del test de caminata de seis minutos</article-title>
      </title-group>
      <kwd-group xml:lang="es">
        <kwd>Seguridad</kwd>
        <kwd>caminata</kwd>
        <kwd>ejercicio</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>CARTA AL EDITOR</bold>
      </p>
      <p>
        <fn id="top-body2">
          <label>
            <bold>La seguridad del test de caminata de seis minutos</bold>
          </label>
          <p>
            <bold>Guilherme Veiga Guimar&#227;es<sup>I,II</sup>; Vitor Oliveira Carvalho<sup>I,II</sup>; Juliana Fernanda Belli<sup>I,II</sup></bold>
          </p>
        </fn>
      </p>
      <p><sup>I</sup>Laborat&#243;rio de Insufici&#234;ncia Card&#237;aca e Transplante do Instituto do Cora&#231;&#227;o do Hospital das Cl&#237;nicas da Faculdade de Medicina da USP (InCor HC-FMUSP), S&#227;o Paulo, SP - Brasil</p>
      <p><sup>II</sup>Laborat&#243;rio de Atividade F&#237;sica e Sa&#250;de (LAtiS/InCor), S&#227;o Paulo, SP - Brasil</p>
      <p>Correspondencia</p>
      <p><bold>Palabras-clave:</bold> Seguridad, caminata, ejercicio.</p>
      <p>
        <bold>Se&#241;or Editor,</bold>
      </p>
      <p>Cipriano et alet al<sup>1</sup> estudiaron la seguridad del test de caminata de 6 minutos (TC6) en pacientes en pretransplante card&#237;aco. Basado en el comportamiento cl&#237;nico y electrocardiogr&#225;fico, tal estudio mostr&#243; que el TC6 fue seguro. Dos pacientes presentaron arritmia pre TC6 y no empeoraron ante el esfuerzo, <sup>4</sup> tuvieron elevaci&#243;n significativa en los niveles de lactato, y tres interrumpieron el examen por disnea. Mientras tanto, el test de caminata de 6 minutos puede ser considerado de alta intensidad para algunos pacientes con insuficiencia card&#237;aca.</p>
      <p>La discusi&#243;n acerca de la natureza subm&#225;xima del TC6 no es reciente, as&#237; como su seguridad en pacientes con insuficiencia card&#237;aca<italic><sup>2</sup></italic>. Guimar&#227;es et alet al<sup>2</sup> observaron que en el test ergoespirom&#233;trico TC6, utilizando escala de Borg entre 11 y 13, versus el TC6 utilizando las recomendaciones usuales, la media de la distancia recorrida fue de 332 <italic>versus</italic> 470 m, VO<sub>2</sub> de 60% <italic>versus</italic> 90% del VO<sub>2</sub> pico, frecuencia card&#237;aca de 77% <italic>versus</italic> 89% de la FCmax, y raz&#243;n de intercambio respiratorio de 0,90 <italic>versus</italic> 1,06.</p>
      <p>En la comparaci&#243;n entre los tests, se observ&#243; diferencia estad&#237;stica entre las evaluaciones. De esa forma, siendo el objetivo del TC6 un posible reflejo de la actividad diaria en este grupo de pacientes, el uso de la escala de Borg, entre relativamente f&#225;cil y ligeramente cansados, durante TC6 parece ser m&#225;s adecuado y garantiza la seguridad para tal finalidad3<sup>,</sup>4, adem&#225;s de ser reproducible y asegurar su naturaleza subm&#225;xima<sup>2,5</sup>.</p>
      <p>
        <bold>Respuesta</bold>
      </p>
      <p>El Art&#237;culo de Guimar&#227;es et al<sup>2</sup>, provee informaciones cient&#237;ficas importantes respecto del test de caminata de 6 Minutos, especialmente en cuanto a la comparaci&#243;n con el test "controlado" y test cardiopulmonar m&#225;ximo. Creemos que nuestro art&#237;culo<sup>1</sup> haya provisto informaciones adicionales y cient&#237;ficamente relevantes en cuanto a la intensidad y seguridad, una vez que utiliz&#243; en forma pionera las medidas de lactato y electrocardiograf&#237;a <italic>online</italic> por telemetr&#237;a, respectivamente, durante el test de caminata de 6 Minutos. El estudio de Belardinelli<sup>3</sup> fue citado como referencia en nuestro art&#237;culo (referencia No. 26), mientras tanto, describi&#243; a partir de un estudio de revisi&#243;n, la ocurrencia de arritmias durante un programa de ejercicio para condicionamiento f&#237;sico, y no durante un test de esfuerzo para evaluaci&#243;n cardiorrespiratoria, como el test de caminata de 6 minutos. La aplicaci&#243;n del referido test con el control de la intensidad (Borg) y la reproductibilidad, no fueron objetivos de nuestro estudio<sup>4,5</sup>.</p>
      <p>
        <bold>Referencias</bold>
      </p>
    </body>
  </sub-article>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Letter to the Editor</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Safety of the cardiopulmonary 6-minute walk test</article-title>
      </title-group>
      <kwd-group xml:lang="en">
        <kwd>Safety</kwd>
        <kwd>walking</kwd>
        <kwd>exercise</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>LETTER TO THE EDITOR</bold>
      </p>
      <p>
        <fn id="top-body3">
          <label>
            <bold>Safety of the cardiopulmonary 6-minute walk test</bold>
          </label>
          <p>
            <bold>Guilherme Veiga Guimar&#227;es<sup>I,II</sup>; Vitor Oliveira Carvalho<sup>I,II</sup>; Juliana Fernanda Belli<sup>I,II</sup></bold>
          </p>
        </fn>
      </p>
      <p><sup>I</sup>Laborat&#243;rio de Insufici&#234;ncia Card&#237;aca e Transplante do Instituto do Cora&#231;&#227;o do Hospital das Cl&#237;nicas da Faculdade de Medicina da USP (InCor HC-FMUSP), S&#227;o Paulo, SP - Brazil</p>
      <p><sup>II</sup>Laborat&#243;rio de Atividade F&#237;sica e Sa&#250;de (LAtiS/InCor), S&#227;o Paulo, SP - Brazil</p>
      <p>Mailing address</p>
      <p><bold>Keywords:</bold> Safety; walking; exercise.</p>
      <p>Cipriano et al<sup>1</sup> studied the safety of the cardiopulmonary 6-minute walk test (6MWT) in pre-heart transplant patients. Based on the clinical and electrocardiographic behavior, the study showed the 6MWT was safe. Two patients presented pre-6MWT arrhythmia that did not worsen during exertion, four presented a significant increase in lactate levels and three interrupted the test due to dyspnea.</p>
      <p>However, the 6MWT can be considered of high-intensity for some patients with heart failure (HF)<sup>2</sup>. The discussion regarding the submaximal nature of the 6MWT is not a recent one, as well as the discussion on whether the test is safe for patients with HF2. Guimar&#227;es et al<sup>2</sup> observed that at the ergospirometric 6MWT using the Borg scale between 11 and 13 <italic>vs</italic> the 6MWT using the usual recommendations, the mean walked distance was 332 <italic>versus</italic> 470 m, with a VO<sub>2</sub> of 60% <italic>versus</italic> 90% of VO<sub>2</sub> peak, heart rate of 77% <italic>versus</italic> 89% of HRmax and respiratory exchange rate of 0.90 <italic>versus</italic> 1.06.</p>
      <p>When comparing the two tests, a statistically significant difference was observed between the assessments. Therefore, considering that the objective of the 6MWT is to be a reflection of the daily activities in this group of patients, the use of the Borg scale during the 6MWT between relatively easy and slightly strenuous, seems to be more adequate and guarantees the safety for such purpose<sup>3,4</sup>, in addition to being reproducible and ensuring its submaximal nature<sup>2,5</sup>.</p>
      <p>
        <bold>Answer</bold>
      </p>
      <p>The article by Guimar&#227;es et al<sup>2</sup>, provided important scientific information on the Six-Minute Walk Test (6MWT), especially regarding the comparison with the "controlled" test and the maximal cardiopulmonary test. We believe that our article<sup>1</sup> has provided additional and scientifically relevant information regarding the intensity and safety, as it pioneered the use of lactate levels and electrocardiography results online by telemetry, respectively, during the 6MWT.</p>
      <p>The study by Belardinelli<sup>3</sup> was cited as a reference in our article (Reference #26); however, it described, based on a review study, the occurrence of arrhythmias during an exercise program aiming at physical fitness and not during an exercise test for cardiorespiratory assessment, such as the 6MWT.</p>
      <p>The use of the aforementioned test with the control of intensity (Borg) and the reproducibility were not the objectives of our study<sup>4,5</sup>.</p>
      <p>
        <bold>References</bold>
      </p>
    </body>
  </sub-article>
</article>
