<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">kQQdLWpspxhWZFSWPv3bCVN</article-id>
      <article-id pub-id-type="other">00017</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2009001200017</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(09)09300617</article-id>
      <article-id pub-id-type="doi">10.1590/S0066-782X2009001200017</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigos Originais</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Utilidade do Ultrassom intracard&#237;aco no isolamento de veias pulmonares usando cateter-bal&#227;o a laser</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Leite</surname>
            <given-names>Luiz</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Su</surname>
            <given-names>Wilber</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Johnson</surname>
            <given-names>Susan B.</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Milton</surname>
            <given-names>Mark</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Henz</surname>
            <given-names>Benhur</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Sarabanda</surname>
            <given-names>Alvaro</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Santos</surname>
            <given-names>Simone N.</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Packer</surname>
            <given-names>Douglas L.</given-names>
          </name>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <addr-line>
          <named-content content-type="city">Rochester</named-content>
          <named-content content-type="state"/>
        </addr-line>
        <institution content-type="orgname">Mayo Clinic</institution>
        <institution content-type="orgdiv1">Divis&#227;o de Doen&#231;as Cardiovasculares e Cl&#237;nica M&#233;dica </institution>
        <country country="US">United States</country>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>12</month>
        <year>2009</year>
      </pub-date>
      <volume>93</volume>
      <issue>6</issue>
      <fpage>666</fpage>
      <lpage>671</lpage>
      <history>
        <date date-type="received">
          <day>22</day>
          <month>06</month>
          <year>2008</year>
        </date>
        <date date-type="rev-recd">
          <day>05</day>
          <month>10</month>
          <year>2008</year>
        </date>
        <date date-type="accepted">
          <day>22</day>
          <month>10</month>
          <year>2008</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <abstract>
        <p>FUNDAMENTO: O isolamento das veias pulmonares (IVP) tem sido usado como endpoint para a abla&#231;&#227;o da fibrila&#231;&#227;o atrial (FA) com cateter bal&#227;o. OBJETIVO: Determinar a utilidade do ultrassom intracard&#237;aco (USIC) para guiar o IVP, usando cateter bal&#227;o a laser. M&#201;TODOS: 59 VP foram ablacionadas em 27 c&#227;es. Imagens de Doppler foram usadas para identificar os vazamentos do fluxo sangu&#237;neo entre a VP e o bal&#227;o. Ap&#243;s cada libera&#231;&#227;o de energia, o cateter de mapeamento circular foi reposicionado para verificar se o isolamento tinha sido obtido. A posi&#231;&#227;o de vazamento foi ent&#227;o correlacionada com a posi&#231;&#227;o do gap no estudo patol&#243;gico. A an&#225;lise de regress&#227;o log&#237;stica multivariada foi realizada. RESULTADOS: Cinquenta e nove VP foram submetidas &#224; abla&#231;&#227;o. O tempo m&#233;dio de energia liberada foi de 279&#177;177 seg., o di&#226;metro m&#233;dio do bal&#227;o era de 23&#177;3 mm, e o comprimento m&#233;dio do bal&#227;o era 25&#177;4 mm. O isolamento completo foi obtido em 38/59 (64%), e foi significantemente mais comum sem vazamento: [30/38 (79%) versus 8/23 (35%), p&lt;0,001]. Isso foi independente do tempo de aplica&#231;&#227;o (302&#177;223 seg. vs. 266&#177;148 sec., p=ns), pot&#234;ncia (3,5 W/cm, 4,5 W/cm, e 5,5 W/cm), di&#226;metro do bal&#227;o (24&#177; 3 mm vs. 22&#177; 3 mm, p= ns) e comprimento (27&#177;4 mm vs. 24&#177;4 mm, p=ns). O valor preditivo positivo para previs&#227;o de isolamento completo foi de 65% e o valor preditivo negativo foi 83%. CONCLUS&#195;O: Um vazamento identific&#225;vel entre a VP e o dispositivo de abla&#231;&#227;o por cateter-bal&#227;o observado no USIC &#233; preditor de menor taxa de isolamento de VP mais baixas. O USIC pode ser &#250;til para detectar vazamentos a fim de evitar o uso ineficaz de aplica&#231;&#227;o energia durante a abla&#231;&#227;o circunferencial da VP. Isto tamb&#233;m pode ser &#250;til quando outras energias s&#227;o utilizadas.</p>
      </abstract>
      <kwd-group xml:lang="pt" kwd-group-type="author-generated">
        <kwd>ultra-sonografia</kwd>
        <kwd>abla&#231;&#227;o por cateter</kwd>
        <kwd>veias pulmonares</kwd>
        <kwd>dilata&#231;&#227;o com bal&#227;o</kwd>
      </kwd-group>
      <pub-date publication-format="electronic" date-type="pub">
        <day>05</day>
        <month>05</month>
        <year>2010</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>ARTIGO ORIGINAL </p>
    <p> EXPERIMENTAL </p>
    <p>
      <bold>Utilidade do Ultrassom intracard&#237;aco no isolamento de veias pulmonares usando cateter-bal&#227;o a laser</bold>
    </p>
    <p>
      <bold>Luiz Leite; Wilber Su; Susan B. Johnson; Mark Milton; Benhur Henz; Alvaro Sarabanda; Simone N. Santos; Douglas L. Packer</bold>
    </p>
    <p>Divis&#227;o de Doen&#231;as Cardiovasculares e Cl&#237;nica M&#233;dica - Mayo Clinic, Rochester, Minnesota, USA</p>
    <p>
      <xref ref-type="corresp" rid="back">Correspond&#234;ncia</xref>
    </p>
    <p>
      <bold>RESUMO</bold>
    </p>
    <p><bold>FUNDAMENTO: </bold> O isolamento das veias pulmonares (IVP) tem sido usado como <italic>endpoint</italic> para a abla&#231;&#227;o da fibrila&#231;&#227;o atrial (FA) com cateter bal&#227;o. </p>
    <p><bold>OBJETIVO: </bold> Determinar a utilidade do ultrassom intracard&#237;aco (USIC) para guiar o IVP, usando cateter bal&#227;o a laser. </p>
    <p><bold>M&#201;TODOS: </bold> 59 VP foram ablacionadas em 27 c&#227;es. Imagens de Doppler foram usadas para identificar os vazamentos do fluxo sangu&#237;neo entre a VP e o bal&#227;o. Ap&#243;s cada libera&#231;&#227;o de energia, o cateter de mapeamento circular foi reposicionado para verificar se o isolamento tinha sido obtido. A posi&#231;&#227;o de vazamento foi ent&#227;o correlacionada com a posi&#231;&#227;o do <italic>gap</italic> no estudo patol&#243;gico. A an&#225;lise de regress&#227;o log&#237;stica multivariada foi realizada. </p>
    <p><bold>RESULTADOS: </bold> Cinquenta e nove VP foram submetidas &#224; abla&#231;&#227;o. O tempo m&#233;dio de energia liberada foi de 279&#177;177 seg., o di&#226;metro m&#233;dio do bal&#227;o era de 23&#177;3 mm, e o comprimento m&#233;dio do bal&#227;o era 25&#177;4 mm. O isolamento completo foi obtido em 38/59 (64%), e foi significantemente mais comum sem vazamento: [30/38 (79%) <italic>versus</italic> 8/23 (35%), p&lt;0,001]. Isso foi independente do tempo de aplica&#231;&#227;o (302&#177;223 seg. vs. 266&#177;148 sec., p=ns), pot&#234;ncia (3,5 W/cm, 4,5 W/cm, e 5,5 W/cm), di&#226;metro do bal&#227;o (24&#177; 3 mm <italic>vs</italic>. 22&#177; 3 mm, p= ns) e comprimento (27&#177;4 mm vs. 24&#177;4 mm, p=ns). O valor preditivo positivo para previs&#227;o de isolamento completo foi de 65% e o valor preditivo negativo foi 83%. </p>
    <p><bold>CONCLUS&#195;O: </bold> Um vazamento identific&#225;vel entre a VP e o dispositivo de abla&#231;&#227;o por cateter-bal&#227;o observado no USIC &#233; preditor de menor taxa de isolamento de VP mais baixas. O USIC pode ser &#250;til para detectar vazamentos a fim de evitar o uso ineficaz de aplica&#231;&#227;o energia durante a abla&#231;&#227;o circunferencial da VP. Isto tamb&#233;m pode ser &#250;til quando outras energias s&#227;o utilizadas. </p>
    <p><bold>Palavras chave: </bold> ultra-sonografia, abla&#231;&#227;o por cateter, veias pulmonares, dilata&#231;&#227;o com bal&#227;o.</p>
    <p>
      <bold>Introdu&#231;&#227;o</bold>
    </p>
    <p>A Fibrila&#231;&#227;o Atrial (FA) &#233; uma das arritmias card&#237;acas mais comuns na pr&#225;tica cl&#237;nica. Recentemente, v&#225;rios autores relataram que a maioria das FA parox&#237;sticas pode ser iniciada pelo disparo de focos ect&#243;picos das veias pulmonares (VP)<sup>1-3</sup>. Embora a FA seja resolvida com a elimina&#231;&#227;o desses focos de VP atrav&#233;s de abla&#231;&#227;o por cateter com radiofreq&#252;&#234;ncia (ACRF), as taxas de recorr&#234;ncia da FA s&#227;o altas e algumas complica&#231;&#245;es s&#227;o muito preocupantes<sup>4-6</sup>.</p>
    <p>A fim de diminuir a recorr&#234;ncia da FA e evitar a estenose de VP, o isolamento da VP tem sido proposto como o <italic>endpoint</italic> para a abla&#231;&#227;o, seja com RF ou energia alternativa, tais como ultrassom e laser<sup>7-9</sup>. Um novo m&#233;todo de abla&#231;&#227;o por cateter-bal&#227;o a laser (ACBL) foi recentemente desenvolvido para eletricamente isolar a VP do &#225;trio esquerdo ao criar les&#245;es circunferenciais no &#243;stio da VP<sup>10</sup>. O ultrassom intracard&#237;aco (USIC) tem sido aplicado no laborat&#243;rio de eletrofisiologia para guiar a forma&#231;&#227;o de les&#245;es por RF, para realizar pun&#231;&#227;o transseptal e orientar o posicionamento dos cateteres durante abla&#231;&#227;o da FA<sup>11-13</sup>. Embora a utilidade do USIC ainda n&#227;o seja conhecida na ACBL, ele pode ajudar a determinar a posi&#231;&#227;o do cateter e o contato tecidual adequado.</p>
    <p>Dessa forma, o objetivo do presente estudo foi determinar o papel do USIC ao guiar o isolamento da VP com ACBL e avaliar o papel do contato tecidual direto na forma&#231;&#227;o de les&#227;o e isolamento da VP.</p>
    <p>
      <bold>M&#233;todos</bold>
    </p>
    <p>
      <bold>Prepara&#231;&#227;o dos Animais</bold>
    </p>
    <p>O protocolo do estudo foi aprovado pelo Comit&#234; Institucional de Uso e Cuidados Animais da Mayo Foundation - Institutional Animal Care and Use Committee - e todos os procedimentos foram seguidos de acordo com as diretrizes internacionais. Vinte e sete c&#227;es machos sem ra&#231;a definida (SRD), com peso de 30 a 40 kg, foram anestesiados com nembutal (30 mg/kg) em estudos agudos ou brevital (12.5 mg/kg) seguido de isoflurano (1-3%) em estudos cr&#244;nicos. Ventila&#231;&#227;o mec&#226;nica foi fornecida durante os procedimentos com suplementa&#231;&#227;o de oxig&#234;nio. Ap&#243;s a monitora&#231;&#227;o do ECG ter sido estabelecida, acesso venoso foi obtido percutaneamente ou atrav&#233;s das veias jugulares externas direita e esquerda, usando bainhas 8-12 Fr. A veia femoral direita foi canulada com uma bainha 16 Fr para subsequente acesso &#224; bainha transseptal, como descrito anteriormente<sup>12</sup>. Resumidamente, a pun&#231;&#227;o transseptal foi realizada sob orienta&#231;&#227;o fluorosc&#243;pica e do USIC atrav&#233;s de uma bainha transseptal Mullins e agulha Brockenbrough. Finalmente, uma bainha 8 Fr foi utilizada para canular a art&#233;ria femoral direita para monitora&#231;&#227;o da press&#227;o arterial. Heparina foi administrada para manter o Tempo de Coagula&#231;&#227;o Ativada (TCA) &gt; 300 segundos.</p>
    <p>
      <bold>Imagem do Ultrassom Intracard&#237;aco</bold>
    </p>
    <p>O ultrassom intracard&#237;aco foi realizado utilizando-se um cateter de ultrassom 10 Fr, 5,5-10 MHz, com ponta multidirecional dirig&#237;vel (Acunav; Acuson, Mountain View, CA, EUA) com capacidade de Doppler. Detalhes do modelo do cateter foram relatados anteriormente<sup>11,14,15</sup>. O cateter de ultrassom foi avan&#231;ado atrav&#233;s de uma bainha 12 French na veia jugular externa e posicionada no &#225;trio direito superior, de onde era poss&#237;vel visibilizar o &#225;trio esquerdo e a VP e a posi&#231;&#227;o do cateter-bal&#227;o a laser. O cateter era ent&#227;o acoplado a uma plataforma de imagens ultrassonogr&#225;ficas Sequoia (Acuson, Mountain View, CA, EUA). Antes da aplica&#231;&#227;o do laser, o USIC com Doppler colorido foi usado para avaliar a presen&#231;a de vazamento de fluxo sangu&#237;neo entre a VP alvo e a ACBL para otimizar o contato bal&#227;o-tecido. Al&#233;m disso, o di&#226;metro (anterior-posterior e m&#233;dio-lateral), a circunferencialidade, a &#225;rea do &#225;trio esquerdo, o di&#226;metro do &#243;stio da VP e as velocidades de fluxo de Doppler foram medidos antes e depois da abla&#231;&#227;o usando o USIC.</p>
    <p>
      <bold>Estudo eletrofisiol&#243;gico e abla&#231;&#227;o por bal&#227;o a laser</bold>
    </p>
    <p>Um cateter 7 Fr, deflect&#237;vel, de mapeamento circular foi inserido via bainha transseptal e posicionado na VP-alvo para registro e estimula&#231;&#227;o. Um cateter de 7 Fr, 10-p&#243;los tamb&#233;m foi inserido atrav&#233;s do acesso jugular e posicionado no seio coron&#225;rio. Os eletrogramas intracavit&#225;rios foram mostrados simultaneamente com o ECG de superf&#237;cie e registrados em um sistema multicanal (Prucka Cardiolab System, GE Medical Systems, Waukesha, WI, EUA). O isolamento da VP foi avaliado durante o ritmo sinusal normal e estimula&#231;&#227;o do seio coron&#225;rio distal usando o cateter de mapeamento circular (<xref ref-type="fig" rid="f1">Figura 1</xref>).</p>
    <fig id="f1">
      <graphic xlink:href="1678-4170-abc-93-06-0666-00017-gf01.jpg"/></fig>
    <p>A abla&#231;&#227;o por cateter-bal&#227;o foi realizada pr&#243;xima ao orif&#237;cio da VP atrav&#233;s de abordagem transseptal sob orienta&#231;&#227;o fluorosc&#243;pica e do USIC. Devido &#224; experi&#234;ncia inicial com este novo cateter-bal&#227;o, para este protocolo, as VP superiores foram escolhidas para abla&#231;&#227;o. Ap&#243;s o posicionamento da ponta do bal&#227;o a laser na VP-alvo, o bal&#227;o de abla&#231;&#227;o foi inflado at&#233; uma press&#227;o de 1 ATM com mistura de D<sub>2</sub>O/ contraste radiopaco. Dois tamanhos diferentes de an&#233;is estavam dispon&#237;veis: 17 mm e 22 mm (CardioFocus). Ambos o comprimento e o di&#226;metro do bal&#227;o foram medidos pelo USIC ap&#243;s o mesmo ter sido inflado. A energia laser foi liberada a 3,5 W/cm, 4,5 W/cm, e 5,5 W/cm por 120 a 720 seg. O sistema de abla&#231;&#227;o foi seletivamente acoplado &#224; sa&#237;da do gerador de energia a laser a uma onda cont&#237;nua de 980 nm e transferido para o bal&#227;o de abla&#231;&#227;o atrav&#233;s de fibra &#243;tica.</p>
    <p>A pot&#234;ncia e o tempo durante a abla&#231;&#227;o foram registrados. As veias pulmonares foram selecionadas para abla&#231;&#227;o e o cateter a laser foi avan&#231;ado atrav&#233;s de uma bainha 12 Fr posicionada no &#243;stio da veia e a superf&#237;cie de abla&#231;&#227;o foi posicionado contra o tecido na &#225;rea desejada da VP. Utilizou-se fluoroscopia, reflex&#227;o luminosa e sensor de contato para determinar o contato do bal&#227;o com o tecido e a posi&#231;&#227;o do arranjo do cateter via ultrassom foram utilizados para ajudar a determinar a melhor posi&#231;&#227;o. Um registro de ativa&#231;&#227;o foi feito antes e ap&#243;s cada les&#227;o ter sido criada usando um cateter de mapeamento circular. Se informa&#231;&#227;o da posi&#231;&#227;o fluorosc&#243;pica ou do US indicasse que o contato era grosseiramente sub-&#243;timo, o cateter era reposicionado. A energia a laser foi liberada de acordo com os par&#226;metros de libera&#231;&#227;o estabelecidos. A dura&#231;&#227;o da libera&#231;&#227;o foi de 120 segundos. Ap&#243;s a libera&#231;&#227;o da energia, os limites dos eletrogramas e da estimula&#231;&#227;o foram repetidos. Este procedimento foi repetido por at&#233; 6 vezes ou at&#233; quando o isolamento da VP foi observado. O mapeamento longitudinal e circular da veia foi utilizado para avaliar bloqueio de entrada durante estimula&#231;&#227;o do &#225;trio direito, seio coron&#225;rio e ritmo sinusal.</p>
    <p>
      <bold>Caracteriza&#231;&#227;o Histol&#243;gica das Les&#245;es de Abla&#231;&#227;o</bold>
    </p>
    <p>Ap&#243;s cada sess&#227;o de abla&#231;&#227;o, os animais eram retornados ao biot&#233;rio para monitora&#231;&#227;o p&#243;s-procedimento e 30 dias da fase de matura&#231;&#227;o. Ap&#243;s esse per&#237;odo, os animais foram novamente anestesiados profundamente com nembutal. A fibrila&#231;&#227;o ventricular foi induzida com estimula&#231;&#227;o de alta frequ&#234;ncia e os animais foram exsanguinados. Uma toracotomia lateral direita foi realizada e o cora&#231;&#227;o e o pulm&#227;o foram conjuntamente retirados com o peric&#225;rdio intacto. Uma avalia&#231;&#227;o macrosc&#243;pica foi realizada, durante a qual as superf&#237;cies dos tecidos endoc&#225;rdico e epic&#225;rdico foram revisadas para verificar a falta de continuidade das les&#245;es de abla&#231;&#227;o (<italic>gap</italic>). A rela&#231;&#227;o entre esses locais e quaisquer <italic>gaps</italic> aparentes no anel de abla&#231;&#227;o no orif&#237;cio da veia pulmonar tamb&#233;m foi estabelecida. A localiza&#231;&#227;o do <italic>gap</italic> foi ent&#227;o correlacionada com os achados ultrassonogr&#225;ficos.</p>
    <p>
      <bold>An&#225;lise Estat&#237;stica</bold>
    </p>
    <p>Dados cont&#237;nuos s&#227;o apresentados como m&#233;dias &#177; DP, exceto onde indicado em contr&#225;rio. As diferen&#231;as entre a presen&#231;a e aus&#234;ncia do isolamento da VP foram realizadas atrav&#233;s do teste <italic>t</italic> de Student para vari&#225;veis cont&#237;nuas. Para vari&#225;veis categ&#243;ricas, o teste de Qui-quadrado ou Teste Exato de Fisher foram usados, como apropriado. A an&#225;lise de regress&#227;o log&#237;stica multivariada foi feita para determinar quais do seguintes fatores estavam associados de forma independente com o isolamento da VP: VP submetida &#224; abla&#231;&#227;o, energia liberada, e dura&#231;&#227;o da energia a laser, presen&#231;a de vazamento identificado por USIC, di&#226;metro e comprimento do bal&#227;o para isolamento bem-sucedido da VP. Um m&#233;todo <italic>forward stepwise</italic> (raz&#227;o de probabilidade) foi usado para determinar os preditores significantes de obten&#231;&#227;o de isolamento completo da VP, considerando-se crit&#233;rios de elimina&#231;&#227;o de p &gt; 0,10. O intervalo de confian&#231;a de 95% foi calculado para <italic>odds ratio</italic> ap&#243;s regress&#227;o log&#237;stica. Um valor de p <underline>&lt;</underline> 0,05 foi considerado como estatisticamente significante. O valor preditivo positivo e negativo da presen&#231;a de vazamento foi calculado para a obten&#231;&#227;o de isolamento da VP.</p>
    <p>
      <bold>Resultados</bold>
    </p>
    <p>A abordagem transseptal foi realizada de forma bem sucedida em todos os animais e o cateter bal&#227;o e o cateter de mapeamento circular foram posicionados na VP-alvo. Cinquenta e nove VP foram submetidas &#224; abla&#231;&#227;o em 27 c&#227;es adultos, incluindo 23 VP superiores direitas (VPSD), 27 VP superiores esquerdas (VPSE), 8 VP inferiores esquerdas (VPIE) e 1 VP inferior direita (VPID). Dezessete VP foram submetidas &#224; abla&#231;&#227;o em 7 c&#227;es de forma aguda e 42 VP foram submetidas &#224; abla&#231;&#227;o em 20 c&#227;es de forma cr&#244;nica. Os potenciais das VP foram observados em todas as veias antes da abla&#231;&#227;o &#224; laser durante o ritmo sinusal normal e estimula&#231;&#227;o do seio coron&#225;rio distal.</p>
    <p>
      <bold>Abla&#231;&#227;o por Bal&#227;o &#224; Laser e Isolamento da VP</bold>
    </p>
    <p>O tempo m&#233;dio total de abla&#231;&#227;o foi de 275 &#177; 88 minutos, e o tempo m&#233;dio de fluoroscopia foi de 83 &#177; 18 minutos. De um total de 59 VP, 18, 30% (4 VPSD, 7 VPSE, 6 VPIE e 1 VPID) foram ablacionadas a 3,5 W/cm. Vinte e quatro, 40% VP (11 VPSD, 12 VPSE e 1 VPIE) foram ablacionadas a 4,5 W/cm, e 17, 30% (8 VPSD, 8 VPSE e 1 VPIE) a 5,5 W/cm. Um animal foi submetido &#224; abla&#231;&#227;o de dois ramos separados da VPSD. A dura&#231;&#227;o m&#233;dia da energia aplicada foi 279 &#177; 177 seg. O isolamento completo da VP foi obtido em 38/59 (64%) das VP submetidas &#224; abla&#231;&#227;o. N&#227;o houve diferen&#231;a na dura&#231;&#227;o m&#233;dia da energia aplicada quando o isolamento da VP foi alcan&#231;ado (266 &#177; 148 seg.) quando comparada com aquelas cujo isolamento n&#227;o foi obtido (303 &#177; 223 seg.). A taxa de isolamento da VP foi significantemente mais alta (p=0,002) com uma pot&#234;ncia de 5,5 W/cm (88,9%) e 4,5 W/cm (64,3%) quando comparadas com 3,5 W/cm (30,8%). N&#227;o houve diferen&#231;a entre 4,5 and 5,5 W/cm.</p>
    <p>
      <bold>Achados do Ultrassom Intracard&#237;aco e Dados Patol&#243;gicos</bold>
    </p>
    <p>Com a ponta do cateter do USIC localizado no &#225;trio direito (AD), perto da jun&#231;&#227;o da veia cava superior (VCS) e o AD, foi poss&#237;vel visibilizar o &#225;trio esquerdo, determinar a localiza&#231;&#227;o e di&#226;metro do &#243;stio de todas as VP e medir as velocidades de fluxo da VP pelo Doppler, medidas da ACBL e vazamentos entre a VP e a ACBL. A <xref ref-type="fig" rid="f2">Figura 2</xref> mostra a disposi&#231;&#227;o da ACBL na VP e como o comprimento e o di&#226;metro foram medidos. Ap&#243;s ter sido inflado, o di&#226;metro m&#233;dio da ACBL foi de 23,1 &#177; 3,0 mm, e o comprimento m&#233;dio foi de 25,6 &#177; 4,4 mm. N&#227;o houve diferen&#231;a entre o di&#226;metro e o comprimento da ACBL quando o isolamento da VP foi atingido ou n&#227;o (24,1 &#177; 3,3 mm <italic>vs</italic>. 22,9 &#177; 3,2 mm; 27,2 &#177; 4,1 mm <italic>vs</italic>. 24,8 &#177; 4,3 mm, respectivamente). O di&#226;metro m&#233;dio da VP no orif&#237;cio foi de 14,1 &#177; 2,8 mm, e n&#227;o houve diferen&#231;a entre o isolamento completo e o incompleto (14,4 &#177; 2,9 <italic>vs</italic>. 13,6 &#177; 2,5, <italic>p</italic> = 0,33). A diferen&#231;a entre o di&#226;metro da VP no orif&#237;cio e o di&#226;metro do bal&#227;o ap&#243;s ter sido inflado mostra que havia uma distens&#227;o significante na parede da VP durante a libera&#231;&#227;o da energia a laser.</p>
    <p content-type="asset">
      <fig id="f2">
        <graphic xlink:href="1678-4170-abc-93-06-0666-00017-gf02.jpg"/></fig>
    </p>
    <p>O vazamento de fluxo sangu&#237;neo identificado por Doppler colorido entre a ACBL e o tecido da VP foi detectado em 23 de 59 (39%) VP-alvo. A <xref ref-type="fig" rid="f3">Figura 3</xref> mostra um vazamento na VPSD na parte superior e na VPSE na parte inferior, que se correlacionou com a localiza&#231;&#227;o do <italic>gap</italic> na an&#225;lise patol&#243;gica (<xref ref-type="fig" rid="f4">Figura 4</xref>). A obten&#231;&#227;o de isolamento completo da VP foi significantemente mais comum na aus&#234;ncia de vazamento de fluxo sangu&#237;neo: 30 de 38 (79%) VP, comparadas com 8 de 23 (35%), quando um vazamento foi documentado (p&lt;0,001). A crit&#233;rio da presen&#231;a de vazamento de fluxo sangu&#237;neo atrav&#233;s do USIC teve uma especificidade de 86,8% e uma sensibilidade de 71,5% para n&#227;o obten&#231;&#227;o do isolamento da VP. O valor preditivo positivo para isolamento incompleto foi de 75% e o valor preditivo negativo foi de 84,6%.</p>
    <fig id="f3">
      <graphic xlink:href="1678-4170-abc-93-06-0666-00017-gf03.jpg"/></fig>
    <fig id="f4">
      <graphic xlink:href="1678-4170-abc-93-06-0666-00017-gf04.jpg"/></fig>
    <p>Os 4 vazamentos visibilizados na VPSD estavam localizados na parte inferior. Da mesma forma, na an&#225;lise patol&#243;gica, o <italic>gap</italic> estava presente na parte inferior nas 3 VPSD. De forma similar, houve 11 vazamentos visualizados na VPSE: 10 na parte inferior e 1 lateral. O exame macrosc&#243;pico mostrou 9 <italic>gaps</italic> localizados na parte inferior e nenhum <italic>gap</italic> lateral.</p>
    <p>
      <bold>An&#225;lise por Regress&#227;o Log&#237;stica Multivariada</bold>
    </p>
    <p>Na an&#225;lise por regress&#227;o log&#237;stica multivariada, a aus&#234;ncia de vazamento foi um preditor independente de obten&#231;&#227;o de isolamento da VP. Quando esses achados foram analisados por an&#225;lise multivariada com todos os outros par&#226;metros testados, incluindo tempo de aplica&#231;&#227;o, pot&#234;ncia, VP submetidas &#224; abla&#231;&#227;o, di&#226;metro e comprimento do bal&#227;o, a chance de obter o isolamento da VP foi significantemente maior quando o vazamento n&#227;o era vis&#237;vel ao USIC (<italic>OR: 6.5, IC 95%: 1,4- 29,1)</italic>. O isolamento completo da VP mostrou uma tend&#234;ncia a ser independentemente mais comum com o uso de pot&#234;ncia de 4,5 e 5,5 W/cm do que com 3,5 W/cm (<italic>p</italic> = 0,076, OR: 5,3; IC 95%: 0,84- 33,0). Os vasos superiores, que foram preditores de isolamento el&#233;trico na an&#225;lise univariada, n&#227;o atingiram signific&#226;ncia estat&#237;stica ao n&#237;vel de 0,05 na an&#225;lise multivariada.</p>
    <p>
      <bold>Discuss&#227;o</bold>
    </p>
    <p>Apesar da &#234;nfase de v&#225;rios estudos sobre a import&#226;ncia do contato cateter-tecido, quando uma corrente de radiofrequ&#234;ncia &#233; utilizada como fonte de energia, essa informa&#231;&#227;o tem sido estudada recentemente ao utilizar-se energia a laser, especialmente para abla&#231;&#227;o circunferencial nas VP. O principal achado do presente estudo foi o estabelecimento da utilidade do USIC para guiar a abla&#231;&#227;o da VP, usando um novo tipo de abla&#231;&#227;o por cateter-bal&#227;o de fibra &#243;tica com energia a laser. Observamos que o isolamento el&#233;trico completo da VP era significantemente mais comum quando n&#227;o havia identifica&#231;&#227;o de vazamento de luxo sangu&#237;neo entre o tecido da VP e a abla&#231;&#227;o por cateter-bal&#227;o, o que determina a import&#226;ncia do contato cateter-bal&#227;o-tecido tamb&#233;m com o uso da energia a laser. Um bom contato entre o bal&#227;o e o orif&#237;cio da VP &#233; necess&#225;rio para obter uma les&#227;o circunferencial<sup>14-17</sup>. Essas necessidades est&#227;o provavelmente relacionadas &#224; intera&#231;&#245;es fotomec&#226;nicas e fotot&#233;rmicas entre a energia a laser no tecido e a transfer&#234;ncia de calor, o que pode ser influenciado pelas caracter&#237;sticas da circula&#231;&#227;o sangu&#237;nea e tecido. O ultrassom intracard&#237;aco usando um cateter de ultrassom com arranjo de fase com ponta multidirecional dirig&#237;vel fornece uma excelente vis&#227;o das veias pulmonares e dos cateteres colocados dentro desses vasos<sup>18-20</sup>. A posi&#231;&#227;o do cateter-bal&#227;o na VP-alvo foi confirmada antes de cada aplica&#231;&#227;o, e o uso de Doppler colorido mostrou a obten&#231;&#227;o do contato entre a parede da VP e a superf&#237;cie do cateter-bal&#227;o. O USIC tem se mostrado muito &#250;til na eletrofisiologia intervencionista, incluindo a cateteriza&#231;&#227;o transseptal, visualiza&#231;&#227;o de estruturas anat&#244;micas-alvo e avalia&#231;&#227;o do contato cateter-tecido. Mangrum e cols.<sup>20</sup> relataram a utilidade do USIC para guiar o isolamento da VP em seres humanos, mostrando a possibilidade de visualizar o posicionamento do cateter, contato com o tecido e forma&#231;&#227;o de les&#227;o, mas usando o sistema rotacional mec&#226;nico<sup>20</sup>. Como novas tecnologias para isolamento da VP usando cateter-bal&#227;o circunferencial foram desenvolvidas, adicionamos a utilidade do Doppler de fluxo colorido para esse tipo de procedimento e, que seja de nosso conhecimento, este &#233; o primeiro estudo que mostra a import&#226;ncia do contato com o tecido usando abla&#231;&#227;o a laser.</p>
    <p>Desde o primeiro estudo relatado por Jais e cols.<sup>21</sup> de uma origem focal da FA desencadeada por batimentos ect&#243;picos originados nas VP v&#225;rios investigadores demonstraram que a energia de RF dirigida a esses focos elimina os batimentos iniciantes da VP e a FA parox&#237;stica<sup>21</sup>. Entretanto, as taxas de recorr&#234;ncia da FA ap&#243;s a abla&#231;&#227;o bem sucedida ainda s&#227;o altas e complica&#231;&#245;es podem se desenvolver ap&#243;s o procedimento<sup>22,23</sup>. A energia de RF tamb&#233;m tem sido usada para isolar a VP ao criar uma les&#227;o circunferencial cont&#237;nua no orif&#237;cio. Alternativamente, diferentes fontes de energia tem sido utilizadas para abla&#231;&#227;o circunferencial atrav&#233;s de energia radial. Natale e cols.<sup>7</sup> relataram o uso de cateter-bal&#227;o de ultrassom para isolar a VP a partir do &#225;trio esquerdo, o que foi obtido em 60% dos casos<sup>7</sup>. No presente estudo, o isolamento da VP foi obtida em 64% dos casos ap&#243;s uma dura&#231;&#227;o m&#233;dia de libera&#231;&#227;o de energia de 280 &#177; 177 seg., o que &#233; bastante similar &#224;quela utilizada por Natale e cols.<sup>7</sup> Entretanto, nossas taxas de isolamento de VP aumentaram para 79% quando n&#227;o foram observados vazamentos de fluxo sangu&#237;neo.</p>
    <p>
      <bold>Limita&#231;&#245;es do Estudo</bold>
    </p>
    <p>Este estudo apresenta varias limita&#231;&#245;es a serem consideradas. Embora a imagem do USIC tenha mostrado de forma clara o &#225;trio esquerdo e a jun&#231;&#227;o de todas as veias na VP, o n&#250;mero de veias inferiores submetidas &#224; abla&#231;&#227;o &#233; muito pequeno comparado ao n&#250;mero de veias superiores, e n&#227;o fomos capazes de demonstrar a mesma utilidade para os dois tipos. Finalmente, estudos adicionais s&#227;o necess&#225;rios para comparar o uso do USIC com outras novas tecnologias desenvolvidas para estabelecer o contato cateter-tecido. Outra potencial limita&#231;&#227;o foi a compara&#231;&#227;o entre o tamanho da VP e o tamanho do bal&#227;o, o qual n&#227;o se ajustava. Entretanto, o fato de o di&#226;metro m&#233;dio do bal&#227;o depois de inflado ser significantemente maior do que o di&#226;metro da VP no orif&#237;cio de fato melhora o contato cateter-bal&#227;o-tecido.</p>
    <p>
      <bold>Implica&#231;&#245;es Cl&#237;nicas</bold>
    </p>
    <p>O contato cateter-tecido mostrou ser importante tamb&#233;m para a abla&#231;&#227;o circunferencial a laser usando o cateter bal&#227;o. Para esse prop&#243;sito, o ultrassom intracard&#237;aco (USIC) poder ser &#250;til ao mostrar o vazamento do fluxo sangu&#237;neo durante a libera&#231;&#227;o de energia, o que aumenta a possibilidade de atingir o isolamento completo da VP. Como conseq&#252;&#234;ncia, o uso do USIC poderia evitar a aplica&#231;&#227;o ineficaz de energia durante a abla&#231;&#227;o circunferencial da VP e isso diminuiria o risco de estenose da VP.</p>
    <p>
      <bold>Potencial Conflito de Interesses</bold>
    </p>
    <p>Declaro n&#227;o haver conflito de interesses pertinentes.</p>
    <p>
      <bold>Fontes de Financiamento</bold>
    </p>
    <p>O presente estudo n&#227;o teve fontes de financiamento externas.</p>
    <p>
      <bold>Vincula&#231;&#227;o Acad&#234;mica</bold>
    </p>
    <p>Este artigo &#233; parte de tese de p&#243;s-doutorado de Luiz Roberto Leite da Silva pela Mayo Clinic Foundation.</p>
    <p>
      <fn id="back" fn-type="corresp">
        <p>Correspond&#234;ncia:</p>
        <p> Luiz Leite </p>
        <p> SHIS QI 15 Conjunto G Bloco 3 - Subsolo </p>
        <p> Lago Sul, Bras&#237;lia, DF, Brasil </p>
        <p> E-mail: </p>
        <p>
          <email xlink:href="leite.luiz@brturbo.com.br">leite.luiz@brturbo.com.br</email>
        </p>
      </fn>
    </p>
    <p>Artigo recebido em 22/06/08; revisado recebido em 05/10/08; aceito em 22/10/08</p>
  </body>
  <back>
    <ref-list>
      <ref id="B1">
        <mixed-citation>1. Chen SA, Tai    CT, Tsai CF, Hsieh MH, Ding YA, Chang MS. Radiofrequency catheter ablation of    atrial fibrillation initiated by pulmonary vein ectopic beats. J Cardiovasc    Electrophysiol. 2000; 11: 218-27.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Radiofrequency catheter ablation of atrial fibrillation initiated by pulmonary vein ectopic beats</article-title>
          <source>J Cardiovasc Electrophysiol</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>218</fpage>
          <lpage>27</lpage>
          <volume>11</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Chen</surname>
              <given-names>SA</given-names>
            </name>
            <name>
              <surname>Tai</surname>
              <given-names>CT</given-names>
            </name>
            <name>
              <surname>Tsai</surname>
              <given-names>CF</given-names>
            </name>
            <name>
              <surname>Hsieh</surname>
              <given-names>MH</given-names>
            </name>
            <name>
              <surname>Ding</surname>
              <given-names>YA</given-names>
            </name>
            <name>
              <surname>Chang</surname>
              <given-names>MS</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Arentz T, Blum    T, von Rosenthal J, Peters K, Kalusche D. Focal paroxysmal atrial fibrillation:    experiences with treatment using high frequency catheter ablation. Dtsch Med    Wochenschr. 2000; 125: 479-83.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Focal paroxysmal atrial fibrillation: experiences with treatment using high frequency catheter ablation</article-title>
          <source>Dtsch Med Wochenschr</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>479</fpage>
          <lpage>83</lpage>
          <volume>125</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Arentz</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Blum</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>von Rosenthal</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Peters</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Kalusche</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. Haissaguerre    M, Jais P, Shah DC, Takahashi A, Hocini M, Quinion G, et al. Spontaneous initiation    of atrial fibrillation by ectopic beats originating in the pulmonary veins.    N Engl J Med. 1998; 339: 659-66.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins</article-title>
          <source>N Engl J Med</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>659</fpage>
          <lpage>66</lpage>
          <volume>339</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Haissaguerre</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Jais</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Shah</surname>
              <given-names>DC</given-names>
            </name>
            <name>
              <surname>Takahashi</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Hocini</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Quinion</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Robbins IM,    Colvin EV, Doyle TP, Kemp WE, Loyd JE, McMahon WS, et al. Pulmonary vein stenosis    after catheter ablation of atrial fibrillation. Circulation. 1998; 98: 1769-75.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Pulmonary vein stenosis after catheter ablation of atrial fibrillation</article-title>
          <source>Circulation</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>1769</fpage>
          <lpage>75</lpage>
          <volume>98</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Robbins</surname>
              <given-names>IM</given-names>
            </name>
            <name>
              <surname>Colvin</surname>
              <given-names>EV</given-names>
            </name>
            <name>
              <surname>Doyle</surname>
              <given-names>TP</given-names>
            </name>
            <name>
              <surname>Kemp</surname>
              <given-names>WE</given-names>
            </name>
            <name>
              <surname>Loyd</surname>
              <given-names>JE</given-names>
            </name>
            <name>
              <surname>McMahon</surname>
              <given-names>WS</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. Sohn RH, Schiller    NB. Left upper pulmonary vein stenosis 2 months after radiofrequency catheter    ablation of atrial fibrillation. Circulation. 2000; 101: E154-5.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Left upper pulmonary vein stenosis 2 months after radiofrequency catheter ablation of atrial fibrillation</article-title>
          <source>Circulation</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>E154</fpage>
          <lpage>5</lpage>
          <volume>101</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Sohn</surname>
              <given-names>RH</given-names>
            </name>
            <name>
              <surname>Schiller</surname>
              <given-names>NB</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B6">
        <mixed-citation>6. Taylor GW, Kay    GN, Zheng X, Bishop S, Ideker RE. Pathological effects of extensive radiofrequency    energy applications in the pulmonary veins in dogs. Circulation. 2000; 101:    1736-42.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Pathological effects of extensive radiofrequency energy applications in the pulmonary veins in dogs</article-title>
          <source>Circulation</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>1736</fpage>
          <lpage>42</lpage>
          <volume>101</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Taylor</surname>
              <given-names>GW</given-names>
            </name>
            <name>
              <surname>Kay</surname>
              <given-names>GN</given-names>
            </name>
            <name>
              <surname>Zheng</surname>
              <given-names>X</given-names>
            </name>
            <name>
              <surname>Bishop</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Ideker</surname>
              <given-names>RE</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B7">
        <mixed-citation>7. Natale A, Pisano    E, Shewchik J, Bash D, Fanelli R, Potenza D, et al. First human experience with    pulmonary vein isolation using a through- the-balloon circumferential ultrasound    ablation system for recurrent atrial fibrillation. Circulation. 2000; 102: 1879-82.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>First human experience with pulmonary vein isolation using a through- the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation</article-title>
          <source>Circulation</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>1879</fpage>
          <lpage>82</lpage>
          <volume>102</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Natale</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Pisano</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Shewchik</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Bash</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Fanelli</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Potenza</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B8">
        <mixed-citation>8. Haissaguerre    M, Jais P, Shah DC, Garrigue S, Takahashi A, Laverne T, et al. Electrophysiological    end point for catheter ablation of atrial fibrillation initiated from multiple    pulmonary venous foci. Circulation. 2000; 101: 1409-17.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci</article-title>
          <source>Circulation</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>1409</fpage>
          <lpage>17</lpage>
          <volume>101</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Haissaguerre</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Jais</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Shah</surname>
              <given-names>DC</given-names>
            </name>
            <name>
              <surname>Garrigue</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Takahashi</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Laverne</surname>
              <given-names>T</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B9">
        <mixed-citation>9. Oral H, Knight    BP, Tada H, Ozaydin M, Chugh A, Hassan S, et al. Pulmonary vein isolation for    paroxysmal and persistent atrial fibrillation. Circulation. 2002; 105: 1077-81.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation</article-title>
          <source>Circulation</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>1077</fpage>
          <lpage>81</lpage>
          <volume>105</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Oral</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Knight</surname>
              <given-names>BP</given-names>
            </name>
            <name>
              <surname>Tada</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Ozaydin</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Chugh</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Hassan</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B10">
        <mixed-citation>10. Su W, Johnson    S, Packer D. First experience with circumferential pulmonary vein ablation using    a laser energy balloon catheter. Circulation. 2001; 104: II-567.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>First experience with circumferential pulmonary vein ablation using a laser energy balloon catheter</article-title>
          <source>Circulation</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>II</fpage>
          <lpage>567</lpage>
          <volume>104</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Su</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Johnson</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Packer</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B11">
        <mixed-citation>11. Packer DL,    Stevens CL, Curley MG, Bruce CJ, Miller FA, Khandheria BK, et al. Intracardiac    phased-array imaging: methods and initial clinical experience with high resolution,    under blood visualization: initial experience with intracardiac phased-array    ultrasound. J Am Coll Cardiol. 2002; 39: 509-16.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Intracardiac phased-array imaging: methods and initial clinical experience with high resolution, under blood visualization: initial experience with intracardiac phased-array ultrasound</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>509</fpage>
          <lpage>16</lpage>
          <volume>39</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Packer</surname>
              <given-names>DL</given-names>
            </name>
            <name>
              <surname>Stevens</surname>
              <given-names>CL</given-names>
            </name>
            <name>
              <surname>Curley</surname>
              <given-names>MG</given-names>
            </name>
            <name>
              <surname>Bruce</surname>
              <given-names>CJ</given-names>
            </name>
            <name>
              <surname>Miller</surname>
              <given-names>FA</given-names>
            </name>
            <name>
              <surname>Khandheria</surname>
              <given-names>BK</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B12">
        <mixed-citation>12. Johnson SB,    Seward JB, Packer DL. Phased-array intracardiac echocardiography for guiding    transseptal catheter placement: utility and learning curve. Pacing Clin Electrophysiol.    2002; 25: 402-7.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Phased-array intracardiac echocardiography for guiding transseptal catheter placement: utility and learning curve</article-title>
          <source>Pacing Clin Electrophysiol</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>402</fpage>
          <lpage>7</lpage>
          <volume>25</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Johnson</surname>
              <given-names>SB</given-names>
            </name>
            <name>
              <surname>Seward</surname>
              <given-names>JB</given-names>
            </name>
            <name>
              <surname>Packer</surname>
              <given-names>DL</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B13">
        <mixed-citation>13. Morton JB,    Sanders P, Byrne MJ, Power J, Mow C, Edwards GA, et al. Phased-Array intracardiac    echocardiography to guide radiofrequency ablation in the left atrium and at    the pulmonary vein ostium. J Cardiovasc Electrophysiol 2001;12 (3): 343-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Phased-Array intracardiac echocardiography to guide radiofrequency ablation in the left atrium and at the pulmonary vein ostium</article-title>
          <source>J Cardiovasc Electrophysiol</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>343</fpage>
          <lpage>8</lpage>
          <issue>3</issue>
          <volume>12</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Morton</surname>
              <given-names>JB</given-names>
            </name>
            <name>
              <surname>Sanders</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Byrne</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Power</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Mow</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Edwards</surname>
              <given-names>GA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B14">
        <mixed-citation>14. Reddy VY, Houghtaling    C, Fallon J, Fisher G, Farr N, Clarke J, et al. Use of diode laser balloon ablation    catheter to generate cincunferential pulmonary venous lesions in a open-thoracotomy    caprine model. Pacing Clin Electrophysiol. 2004; 27: 52-7.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Use of diode laser balloon ablation catheter to generate cincunferential pulmonary venous lesions in a open-thoracotomy caprine model</article-title>
          <source>Pacing Clin Electrophysiol</source>
          <date>
            <year>2004</year>
          </date>
          <fpage>52</fpage>
          <lpage>7</lpage>
          <volume>27</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Reddy</surname>
              <given-names>VY</given-names>
            </name>
            <name>
              <surname>Houghtaling</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Fallon</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Fisher</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Farr</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Clarke</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B15">
        <mixed-citation>15. Whelan WM,    Wyman DR, Wilson B. Investigations of large vessel cooling during interstitial    laser heating. Med Phys. 1995; 22 (1): 105-15.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Investigations of large vessel cooling during interstitial laser heating</article-title>
          <source>Med Phys</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>105</fpage>
          <lpage>15</lpage>
          <issue>1</issue>
          <volume>22</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Whelan</surname>
              <given-names>WM</given-names>
            </name>
            <name>
              <surname>Wyman</surname>
              <given-names>DR</given-names>
            </name>
            <name>
              <surname>Wilson</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B16">
        <mixed-citation>16. Chen L, ter    Haar G, Hill CR, Dworkin M, Carnochan P, Young H, et al. Effect of blood perfusion    on the ablation of liver parenchyma with high-intensity focused ultrasound.    Phys Med Biol. 1993; 38: 1661-173.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound</article-title>
          <source>Phys Med Biol</source>
          <date>
            <year>1993</year>
          </date>
          <fpage>1661</fpage>
          <lpage>173</lpage>
          <volume>38</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Chen</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>ter Haar</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Hill</surname>
              <given-names>CR</given-names>
            </name>
            <name>
              <surname>Dworkin</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Carnochan</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Young</surname>
              <given-names>H</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B17">
        <mixed-citation>17. Liu Z, Ahmed    M, Weistein Y, Yi M, Mahajan RL, Goldberg SN. Characterization of the RF ablation-induced    "oven effect": the importance of background tissue thermal conductivity on tissue    heating. Int J Hyperthermia. 2006; 22: 327-42.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Characterization of the RF ablation-induced "oven effect": the importance of background tissue thermal conductivity on tissue heating</article-title>
          <source>Int J Hyperthermia</source>
          <date>
            <year>2006</year>
          </date>
          <fpage>327</fpage>
          <lpage>42</lpage>
          <volume>22</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Liu</surname>
              <given-names>Z</given-names>
            </name>
            <name>
              <surname>Ahmed</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Weistein</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Yi</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Mahajan</surname>
              <given-names>RL</given-names>
            </name>
            <name>
              <surname>Goldberg</surname>
              <given-names>SN</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B18">
        <mixed-citation>18. Bruce CJ, Packer    DL, O'Leary PW, Seward JB. Feasibility study: transesophageal echocardiography    with a 10F (3.2- mm), multifrequency (5.5- to 10-MHz) ultrasound catheter in    a small rabbit model. J Am Soc Echocardiogr. 1999; 12: 596-600.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Feasibility study: transesophageal echocardiography with a 10F (3.2- mm), multifrequency (5.5- to 10-MHz) ultrasound catheter in a small rabbit model</article-title>
          <source>J Am Soc Echocardiogr</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>596</fpage>
          <lpage>600</lpage>
          <volume>12</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Bruce</surname>
              <given-names>CJ</given-names>
            </name>
            <name>
              <surname>Packer</surname>
              <given-names>DL</given-names>
            </name>
            <name>
              <surname>O'Leary</surname>
              <given-names>PW</given-names>
            </name>
            <name>
              <surname>Seward</surname>
              <given-names>JB</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B19">
        <mixed-citation>19. Bruce CJ, Packer    DL, Belohlavek M, Seward JB. Intracardiac echocardiography: newest technology.    J Am Soc Echocardiogr. 2000; 13: 788-95.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Intracardiac echocardiography: newest technology</article-title>
          <source>J Am Soc Echocardiogr</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>788</fpage>
          <lpage>95</lpage>
          <volume>13</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Bruce</surname>
              <given-names>CJ</given-names>
            </name>
            <name>
              <surname>Packer</surname>
              <given-names>DL</given-names>
            </name>
            <name>
              <surname>Belohlavek</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Seward</surname>
              <given-names>JB</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B20">
        <mixed-citation>20. Mangrum JM,    Mounsey JP, Kok LC, De Marco JP, Haines DE. Intracardiac echocardiography-guided,    anatomically based radiofrequency ablation of focal atrial fibrillation originating    from pulmonary veins. J Am Coll Cardiol. 2002; 39: 1964-72.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Intracardiac echocardiography-guided, anatomically based radiofrequency ablation of focal atrial fibrillation originating from pulmonary veins</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>1964</fpage>
          <lpage>72</lpage>
          <volume>39</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Mangrum</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Mounsey</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>Kok</surname>
              <given-names>LC</given-names>
            </name>
            <name>
              <surname>De Marco</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>Haines</surname>
              <given-names>DE</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B21">
        <mixed-citation>21. Jais P, Haissaguerre    M, Shah DC, Chouairi S, Gencel L, Hocini M, et al. A focal source of atrial    fibrillation treated by discrete radiofrequency ablation. Circulation. 1997;    95: 572-6.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>A focal source of atrial fibrillation treated by discrete radiofrequency ablation</article-title>
          <source>Circulation</source>
          <date>
            <year>1997</year>
          </date>
          <fpage>572</fpage>
          <lpage>6</lpage>
          <volume>95</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Jais</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Haissaguerre</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Shah</surname>
              <given-names>DC</given-names>
            </name>
            <name>
              <surname>Chouairi</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Gencel</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Hocini</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B22">
        <mixed-citation>22. Oral H, Knight    BP, Ozaydin M, Toda H, Chugh A, Hassan S, et al. Clinical significance of early    recurrences of atrial fibrillation after pulmonary vein isolation. J Am Coll    Cardiol. 2002; 40 (1): 100-4.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Clinical significance of early recurrences of atrial fibrillation after pulmonary vein isolation</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>100</fpage>
          <lpage>4</lpage>
          <issue>1</issue>
          <volume>40</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Oral</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Knight</surname>
              <given-names>BP</given-names>
            </name>
            <name>
              <surname>Ozaydin</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Toda</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Chugh</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Hassan</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B23">
        <mixed-citation>23. Cappato R,    Calkins H, Chen SA, Davies W, Iesaka Y, Kalman J, et al. Worldwide survey on    the methods, efficacy, and safety of catheter ablation for human atrial fibrillation.    Circulation. 2005; 111: 1100-105.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation</article-title>
          <source>Circulation</source>
          <date>
            <year>2005</year>
          </date>
          <fpage>1100</fpage>
          <lpage>105</lpage>
          <volume>111</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Cappato</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Calkins</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Chen</surname>
              <given-names>SA</given-names>
            </name>
            <name>
              <surname>Davies</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Iesaka</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Kalman</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="TRes" xml:lang="es">
    <front-stub>
      <article-categories/>
      <title-group>
        <article-title xml:lang="es">Utilidad del ultrasonido intracard&#237;aco en el aislamiento de venas pulmonares usando cat&#233;ter-bal&#243;n l&#225;ser</article-title>
      </title-group>
      <abstract xml:lang="es">
        <p>FUNDAMENTO: Se us&#243; el aislamiento de las venas pulmonares (AVP) como endpoint para la ablaci&#243;n de la fibrilaci&#243;n atrial (FA) con cat&#233;ter-bal&#243;n. OBJETIVO: Determinar la utilidad del ultrasonido intracard&#237;aco (USIC) para guiar el AVP, usando cat&#233;ter-bal&#243;n l&#225;ser. M&#201;TODOS: Se ablacionaron 59 VP en 27 perros. Se usaron im&#225;genes de Doppler para identificar los derrames del flujo sangu&#237;neo entre la VP y el bal&#243;n. Tras cada liberaci&#243;n de energ&#237;a, se reposicion&#243; el cat&#233;ter de mapeamiento circular para verificar si se obtuvo el aislamiento. Se correlaccion&#243;, entonces, la posici&#243;n del derrame con la posici&#243;n del gap en el estudio patol&#243;gico. Se realiz&#243; el an&#225;lisis de regresi&#243;n log&#237;stica multivariada. RESULTADOS: Se sometieron 59 VP a la ablaci&#243;n. El tiempo promedio de energ&#237;a liberada fue de 279&#177;177 seg., el di&#225;metro promedio del bal&#243;n era de 23&#177;3 mm, y la largura promedio del bal&#243;n era 25&#177;4 mm. Se obtuvo el aislamiento completo en 38/59 (64%), y fue significantemente m&#225;s com&#250;n sin derrame: [30/38 (79%) versus 8/23 (35%), p&lt;0,001]. Eso fue independiente del tiempo de aplicaci&#243;n (302&#177;223 seg. vs. 266&#177;148 sec., p=ns), potencia (3,5 W/cm, 4,5 W/cm, y 5,5 W/cm), di&#225;metro del bal&#243;n (24&#177; 3 mm vs. 22&#177; 3 mm, p= ns) y largura (27&#177;4 mm vs. 24&#177;4 mm, p=ns). El valor predictivo positivo para la previsi&#243;n del aislamiento completo fue del 65% y el valor predictivo negativo fue del 83%. CONCLUSI&#211;N: Un derrame identificable entre la VP y el dispositivo de ablaci&#243;n por cat&#233;ter-bal&#243;n observado en el USIC es predictor de menor tasa del aislamiento de la VP m&#225;s baja. El USIC puede ser &#250;til para detectar derrames a fin de evitar el uso ineficaz de la aplicaci&#243;n de la energ&#237;a durante la ablaci&#243;n circunferencial de la VP. Ello tambi&#233;n puede ser &#250;til cuando se utilizan otras energ&#237;as.</p>
      </abstract>
      <kwd-group xml:lang="es">
        <kwd>Ultrasonograf&#237;a</kwd>
        <kwd>ablaci&#243;n por cat&#233;ter</kwd>
        <kwd>venas pulmonares</kwd>
        <kwd>dilataci&#243;n con bal&#243;n</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>ART&#205;CULO ORIGINAL</bold>
      </p>
      <p>
        <fn id="top-body2">
          <label>
            <bold>Utilidad del ultrasonido intracard&#237;aco en el aislamiento de venas pulmonares usando cat&#233;ter-bal&#243;n l&#225;ser</bold>
          </label>
          <p>
            <bold>Luiz Leite; Wilber Su; Susan B. Johnson; Mark Milton; Benhur Henz; Alvaro Sarabanda; Simone N. Santos; Douglas L. Packer</bold>
          </p>
        </fn>
      </p>
      <p>Divisi&#243;n de Enfermedades Cardiovasculares y Cl&#237;nica M&#233;dica - Mayo Clinic, Rochester, Minnesota, USA</p>
      <p>Correspondencia</p>
      <p>
        <bold>RESUMEN</bold>
      </p>
      <p><bold>FUNDAMENTO: </bold> Se us&#243; el aislamiento de las venas pulmonares (AVP) como <italic>endpoint</italic> para la ablaci&#243;n de la fibrilaci&#243;n atrial (FA) con cat&#233;ter-bal&#243;n.</p>
      <p><bold>OBJETIVO:</bold> Determinar la utilidad del ultrasonido intracard&#237;aco (USIC) para guiar el AVP, usando cat&#233;ter-bal&#243;n l&#225;ser.</p>
      <p><bold>M&#201;TODOS:</bold> Se ablacionaron 59 VP en 27 perros. Se usaron im&#225;genes de Doppler para identificar los derrames del flujo sangu&#237;neo entre la VP y el bal&#243;n. Tras cada liberaci&#243;n de energ&#237;a, se reposicion&#243; el cat&#233;ter de mapeamiento circular para verificar si se obtuvo el aislamiento. Se correlaccion&#243;, entonces, la posici&#243;n del derrame con la posici&#243;n del <italic>gap</italic> en el estudio patol&#243;gico. Se realiz&#243; el an&#225;lisis de regresi&#243;n log&#237;stica multivariada.</p>
      <p><bold>RESULTADOS:</bold> Se sometieron 59 VP a la ablaci&#243;n. El tiempo promedio de energ&#237;a liberada fue de 279&#177;177 seg., el di&#225;metro promedio del bal&#243;n era de 23&#177;3 mm, y la largura promedio del bal&#243;n era 25&#177;4 mm. Se obtuvo el aislamiento completo en 38/59 (64%), y fue significantemente m&#225;s com&#250;n sin derrame: [30/38 (79%) <italic>versus</italic> 8/23 (35%), p&lt;0,001]. Eso fue independiente del tiempo de aplicaci&#243;n (302&#177;223 seg. vs. 266&#177;148 sec., p=ns), potencia (3,5 W/cm, 4,5 W/cm, y 5,5 W/cm), di&#225;metro del bal&#243;n (24&#177; 3 mm <italic>vs</italic>. 22&#177; 3 mm, p= ns) y largura (27&#177;4 mm vs. 24&#177;4 mm, p=ns). El valor predictivo positivo para la previsi&#243;n del aislamiento completo fue del 65% y el valor predictivo negativo fue del 83%.</p>
      <p><bold>CONCLUSI&#211;N:</bold> Un derrame identificable entre la VP y el dispositivo de ablaci&#243;n por cat&#233;ter-bal&#243;n observado en el USIC es predictor de menor tasa del aislamiento de la VP m&#225;s baja. El USIC puede ser &#250;til para detectar derrames a fin de evitar el uso ineficaz de la aplicaci&#243;n de la energ&#237;a durante la ablaci&#243;n circunferencial de la VP. Ello tambi&#233;n puede ser &#250;til cuando se utilizan otras energ&#237;as. </p>
      <p><bold>Palabras claves: </bold> Ultrasonograf&#237;a, ablaci&#243;n por cat&#233;ter, venas pulmonares, dilataci&#243;n con bal&#243;n.</p>
      <p>
        <bold>Introducci&#243;n</bold>
      </p>
      <p>La Fibrilaci&#243;n Atrial (FA) es una de las arritmias card&#237;acas m&#225;s comunes en la pr&#225;ctica cl&#237;nica. Recientemente, varios autores relataron que la mayor&#237;a de las FA parox&#237;sticas puede iniciarse por el disparo de focos ect&#243;picos de las venas pulmonares (VP)<sup>1-3</sup>. Aunque la FA se resuelve con la eliminaci&#243;n de esos focos de VP a trav&#233;s de la ablaci&#243;n por cat&#233;ter con radiofrecuencia (ACRF), las tasas de recurrencia de la FA son altas y algunas complicaciones son muy preocupantes<sup>4-6</sup>.</p>
      <p>A fin de disminuir la recurrencia de la FA y evitar la estenosis de la VP, se viene proponoiendo el aislamiento de la VP como el <italic>endpoint</italic> para la ablaci&#243;n, ya sea con RF o con energ&#237;a alternativa, tales como ultrasonido y l&#225;ser<sup>7-9</sup>. Un nuevo m&#233;todo de ablaci&#243;n por cat&#233;ter-bal&#243;n l&#225;ser (ACBL) se desarroll&#243; recientemente para el&#233;ctricamente aislar la VP del atrio izquierdo al crear lesiones circunferenciales en el ostio de la VP<sup>10</sup>. Se viene aplicando el ultrasonido intracard&#237;aco (USIC) en el laboratorio de electrofisiolog&#237;a para guiar la formaci&#243;n de lesiones por RF, para realizar punci&#243;n transeptal y orientar el posicionamiento de los cat&#233;teres durante la ablaci&#243;n de la FA<sup>11-13</sup>. Aunque la utilidad del USIC todav&#237;a no es conocida en la ACBL, &#233;l puede ayudar a determinar la posici&#243;n del cat&#233;ter y el contacto tisular adecuado.</p>
      <p>As&#237;, el objetivo del presente estudio fue determinar el rol del USIC al guiar el aislamiento de la VP con ACBL y evaluar el rol del contacto tisular directo en la formaci&#243;n de lesi&#243;n y aislamiento de la VP.</p>
      <p>
        <bold>M&#233;todos</bold>
      </p>
      <p>
        <bold>Preparaci&#243;n de los animales</bold>
      </p>
      <p>El Comit&#233; Institucional de Uso y Cuidados Animales de la Mayo Foundation - Institutional Animal Care and Use Committee aprob&#243; el protocolo del estudio y se siguieron todos los procedimientos de acuerdo con las directrices internacionales. Se anestesiaron 27 perros machos sin raza definida (SRD), con peso de 30 a 40 kg, con nembutal (30 mg/kg) en estudios agudos o brevital (12.5 mg/kg) seguido de isoflurano (1-3%) en estudios cr&#243;nicos. Se suministr&#243; ventilaci&#243;n mec&#225;nica durante los procedimientos con suplementaci&#243;n de ox&#237;geno. Tras establecerse la monitorizaci&#243;n del ECG, se obtuvo acceso venoso percut&#225;neo o a trav&#233;s de las venas yugulares externas derecha e izquierda, usando vainas 8-12 Fr. Se canul&#243; la vena femoral derecha con una vaina 16 Fr para subsecuente acceso a la vaina transeptal, como descripto anteriormente<sup>12</sup>. En resumen, se realiz&#243; la punci&#243;n transeptal bajo la orientaci&#243;n fluorosc&#243;pica y del USIC a trav&#233;s de una vaina transeptal Mullins y una aguja Brockenbrough. Por fin, se utiliz&#243; una vaina 8 para canular la arteria femoral derecha para monitorizaci&#243;n de la presi&#243;n arterial. Se suministr&#243; Heparina para mantener el Tiempo de Coagulaci&#243;n Activada (TCA) &gt; 300 segundos.</p>
      <p>
        <bold>Imagen del ultrasonido intracard&#237;aco</bold>
      </p>
      <p>Se realiz&#243; el ultrasonido intracard&#237;aco utiliz&#225;ndose un cat&#233;ter de ultrasonido 10 Fr, 5,5-10 MHz, con punta multidireccional dirigible (Acunav; Acuson, Mountain View, CA, EUA) con capacidad de Doppler. Se relataron anteriormente los detalles del modelo del cat&#233;ter<sup>11,14,15</sup>. Se avanz&#243; el cat&#233;ter de ultrasonido a trav&#233;s de una vaina 12 French en la vena yugular externa, posicionada en el atrio derecho superior, donde se pod&#237;a visualizar el atrio izquierdo y la VP y la posici&#243;n del cat&#233;ter-bal&#243;n l&#225;ser. As&#237; que se acoplaba el cat&#233;ter a una plataforma de im&#225;genes ultrasonogr&#225;ficas Sequoia (Acuson, Mountain View, CA, EUA). Antes de la aplicaci&#243;n del l&#225;ser, se us&#243; el USIC con Doppler color para evaluar la presencia de derrame de flujo sangu&#237;neo entre la VP objetivo y la ACBL para optimizar el contacto bal&#243;n-tejido. Adem&#225;s, se midieron el di&#225;metro (anterior-posterior y mediano-lateral), la circunferencialidad y el &#225;rea del atrio izquierdo y el di&#225;metro del ostio de la VP y las velocidades de flujo de Doppler antes y despu&#233;s de la ablaci&#243;n usando el USIC.</p>
      <p>
        <bold>Estudio electrofisiol&#243;gico y ablaci&#243;n por bal&#243;n l&#225;ser</bold>
      </p>
      <p>Se insert&#243; un cat&#233;ter 7 Fr, deflectable, de mapeamiento circular, v&#237;a la vaina transeptal, posicionada en la VP-objetivo para registro y estimulaci&#243;n. Tambi&#233;n se insert&#243; un cat&#233;ter de 7 Fr, 10-polos a trav&#233;s del acceso yugular, posicionado en el seno coronario. Se mostraron los electrogramas intracavitarios simult&#225;neamente con el ECG de superficie y registrados en un sistema multicanal (Prucka Cardiolab System, GE Medical Systems, Waukesha, WI, EUA). Se evalu&#243; el aislamiento de la VP durante el ritmo sinusal normal y estimulaci&#243;n del seno coronario distal usando el cat&#233;ter de mapeamiento circular (<xref ref-type="fig" rid="f1-body2">Figura 1</xref>).</p>
      <fig id="f1-body2">
        <graphic xlink:href="1678-4170-abc-93-06-0666-00017-gf01-es.jpg"/></fig>
      <p>Se realiz&#243; la ablaci&#243;n por cat&#233;ter-bal&#243;n pr&#243;xima al orificio de la VP a trav&#233;s del abordaje transeptal bajo la orientaci&#243;n fluorosc&#243;pica y del USIC. Debido a la experiencia inicial con este nuevo cat&#233;ter-bal&#243;n, para este protocolo, se eligieron las VP superiores para ablaci&#243;n. Tras el posicionamiento de la punta del bal&#243;n l&#225;ser en la VP-objetivo, se infl&#243; el bal&#243;n de ablaci&#243;n hasta una presi&#243;n de 1 ATM con mezcla de D<sub>2</sub>O/ contraste radiopaco. Dos tama&#241;os distintos de anillos estaban disponibles: 17 mm y 22 mm (CardioFocus). Se midieron la largura y el di&#225;metro del bal&#243;n por el USIC tras inflarse el mismo. Se liber&#243; la energ&#237;a l&#225;ser a 3,5 W/cm, 4,5 W/cm, y 5,5 W/cm por 120 a 720 seg. Se acopl&#243; selectivamente el sistema de ablaci&#243;n a la salida del generador de energ&#237;a l&#225;ser a una onda continua de 980 nm y se transfiri&#243; al bal&#243;n de ablaci&#243;n a trav&#233;s de fibra &#243;ptica.</p>
      <p>Se registraron la potencia y el tiempo durante la ablaci&#243;n. Se seleccionaron las venas pulmonares para ablaci&#243;n y se avanz&#243; el cat&#233;ter l&#225;ser a trav&#233;s de una vaina 12 Fr posicionada en el ostio de la vena y se posicion&#243; la superficie de ablaci&#243;n contra el tejido en el &#225;rea deseada de la VP. Se utilizaron la fluoroscopia, la reflexi&#243;n luminosa y el sensor de contacto para determinar el contacto del bal&#243;n con el tejido y la posici&#243;n de la preparaci&#243;n del cat&#233;ter v&#237;a ultrasonido para ayudar a determinar la mejor posici&#243;n. Se hizo antes un registro de activaci&#243;n, tras la creaci&#243;n de cada lesi&#243;n, usando un cat&#233;ter circular de mapeo. Si la informaci&#243;n de la posici&#243;n fluorosc&#243;pica o del US indicara que el contacto era groseramente sub-&#243;ptimo, el cat&#233;ter ser&#237;a reposicionado. Se liber&#243; la energ&#237;a l&#225;ser de acuerdo con los par&#225;metros de liberaci&#243;n establecidos. La duraci&#243;n de la liberaci&#243;n fue de 120 segundos. Tras la liberaci&#243;n de la energ&#237;a, se repitieron los l&#237;mites de los electrogramas y de la estimulaci&#243;n. Se repiti&#243; este procedimiento por hasta 6 veces o hasta cuando se observ&#243; el aislamiento de la VP. Se utiliz&#243; el mapeo longitudinal y circular de la vena para evaluar el bloqueo de entrada durante la estimulaci&#243;n del atrio derecho, seno coronario y ritmo sinusal.</p>
      <p>
        <bold>Caracterizaci&#243;n histol&#243;gica de las lesiones de ablaci&#243;n</bold>
      </p>
      <p>Tras cada sesi&#243;n de ablaci&#243;n, regresaron los animales al bioterio para monitorizaci&#243;n postprocedimiento 30 d&#237;as de la fase de maduraci&#243;n. Tras ese periodo, nuevamente anestesiaron profundamente los animales con nembutal. Se indujo la fibrilaci&#243;n ventricular con estimulaci&#243;n de alta frecuencia y se exanguinaron los animales. Se realiz&#243; una toracotom&#237;a lateral derecha y se retiraron conjuntamente el coraz&#243;n y el pulm&#243;n con el pericardio intacto. Se realiz&#243; una evaluaci&#243;n macrosc&#243;pica, durante la que se revisaron las superficies de los tejidos endoc&#225;rdico y epic&#225;rdico para verificar la falta de continuidad de las lesiones de ablaci&#243;n (<italic>gap</italic>). Se estableci&#243; tambi&#233;n la relaci&#243;n entre esos locales y cualesquier <italic>gaps</italic> aparientes en el anillo de ablaci&#243;n en el orificio de la vena pulmonar. Se correlaccion&#243;, entonces, la localizaci&#243;n del <italic>gap</italic> con los hallazgos ultrasonogr&#225;ficos.</p>
      <p>
        <bold>An&#225;lisis estad&#237;stico</bold>
      </p>
      <p>Se presentan datos continuos como promedios &#177; DE, excepto donde se indica en contrario. Se realizaron las diferencias entre la presencia y la ausencia del aislamiento de la VP a trav&#233;s del test <italic>t</italic> de Student para variables continuas. Para variables categ&#243;ricas, se usaron el test de Qui-cuadrado o Test Exacto de Fisher, como apropiado. Se realiz&#243; el an&#225;lisis de regresi&#243;n log&#237;stica multivariada para determinar cu&#225;les de los siguientes factores estaban asociados de manera independiente con el aislamiento de la VP: VP sometida a la ablaci&#243;n, energ&#237;a liberada, y duraci&#243;n de la energ&#237;a l&#225;ser, presencia de derrame identificado por USIC, di&#225;metro y largura del bal&#243;n para aislamiento exitoso de la VP. Se emple&#243; un m&#233;todo <italic>forward stepwise</italic> (raz&#243;n de probabilidad) para determinar los predictores significantes de obtenci&#243;n del aislamiento completo de la VP, consider&#225;ndose los criterios de eliminaci&#243;n de P &gt; 0,10. Se calcul&#243; el intermedio de confianza del 95% para <italic>odds ratio</italic> tras regresi&#243;n log&#237;stica. Se consider&#243; un valor de P <underline>&lt;</underline> 0,05 como estad&#237;sticamente significante. Se calcul&#243; el valor predictivo positivo y negativo de la presencia del derrame para la obtenci&#243;n del aislamiento de la VP.</p>
      <p>
        <bold>Resultados</bold>
      </p>
      <p>Se realiz&#243; un abordaje transeptal de manera existosa en todos los animales y posicionaron el cat&#233;ter bal&#243;n y el cat&#233;ter de mapeo circular en la VP-objetivo. Se sometieron 59 VP a la ablaci&#243;n en 27 perros adultos, incluyendo 23 VP superiores derechas (VPSD), 27 VP superiores izquierdas (VPSE), 8 VP inferiores izquierdas (VPIE) y 1 VP inferior derecha (VPID). Se sometieron 17 VP a la ablaci&#243;n en 7 perros de forma aguda y sometieron 42 VP a la ablaci&#243;n en 20 perros de forma cr&#243;nica. Se observaron los potenciales de las VP en todas las venas antes de la ablaci&#243;n con l&#225;ser durante el ritmo sinusal normal y estimulaci&#243;n del seno coronario distal.</p>
      <p>
        <bold>Ablaci&#243;n por bal&#243;n l&#225;ser y aislamiento de la VP</bold>
      </p>
      <p>El tiempo promedio total de ablaci&#243;n fue de 275 &#177; 88 minutos, y el tiempo promedio de fluoroscopia fue de 83 &#177; 18 minutos. De un total de 59 VP, 18, se ablacionaron el 30% (4 VPSD, 7 VPSE, 6 VPIE y 1 VPID) a 3,5 W/cm. Se ablacionaron 24, el 40% VP (11 VPSD, 12 VPSE y 1 VPIE) a 4,5 W/cm, y 17, el 30% (8 VPSD, 8 VPSE y 1 VPIE) a 5,5 W/cm. Se sometieron a un animal a la ablaci&#243;n de dos ramas separadas de la VPSD. La duraci&#243;n promedio de la energ&#237;a aplicada fue de 279 &#177; 177 seg. Se obtuvo el aislamiento completo de la VP en 38/59 (64%) de las VP sometidas a la ablaci&#243;n. No hubo diferencia en la duraci&#243;n promedio de la energ&#237;a aplicada cuando se alcanz&#243; el aislamiento de la VP (266 &#177; 148 seg.) cuando comparada con aqu&#233;llas cuyo aislamiento no se obtuvo (303 &#177; 223 seg.). La tasa de aislamiento de la VP fue significantemente m&#225;s alta (p=0,002) con una potencia de 5,5 W/cm (88,9%) y 4,5 W/cm (64,3%) cuando comparadas con 3,5 W/cm (30,8%). No hubo diferencia entre 4,5 y 5,5 W/cm.</p>
      <p>
        <bold>Hallazgos del ultrasonido intracard&#237;aco y datos patol&#243;gicos</bold>
      </p>
      <p>Con la punta del cat&#233;ter del USIC localizado en el atrio derecho (AD), cerca de la uni&#243;n de la vena cava superior (VCS) y el AD, fue posible visualizar el atrio izquierdo, determinar la localizaci&#243;n y el di&#225;metro del ostio de todas las VP y medir las velocidades del flujo de la VP por el Doppler, medidas de la ACBL y derrames entre la VP y la ACBL (Tabla 1). La <xref ref-type="fig" rid="es_17f2-body2">Figura 2</xref> muestra la disposici&#243;n de la ACBL en la VP y como midieron la largura y el di&#225;metro. Tras inflarse, el di&#225;metro promedio de la ACBL fue de 23,1 &#177; 3,0 mm, y la largura promedio fue de 25,6 &#177; 4,4 mm. No hubo diferencia entre el di&#225;metro y la largura de la ACBL cuando se alcanz&#243; o no el aislamiento de la VP (24,1 &#177; 3,3 mm <italic>vs</italic>. 22,9 &#177; 3,2 mm; 27,2 &#177; 4,1 mm <italic>vs</italic>. 24,8 &#177; 4,3 mm, respectivamente). El di&#225;metro promedio de la VP en el orificio fue de 14,1 &#177; 2,8 mm, y no hubo diferencia entre el aislamiento completo y el incompleto (14,4 &#177; 2,9 <italic>vs</italic>. 13,6 &#177; 2,5, <italic>p</italic> = 0,33). La diferencia entre el di&#225;metro de la VP en el orificio y el di&#225;metro del bal&#243;n tras inflarse muestra que hab&#237;a una distensi&#243;n significante en la pared de la VP durante la liberaci&#243;n de la energ&#237;a l&#225;ser.</p>
      <p content-type="asset">
        <fig id="es_17f2-body2">
          <graphic xlink:href="1678-4170-abc-93-06-0666-00017-gf02-es.jpg"/></fig>
      </p>
      <p>Se detect&#243; el derrame de flujo sangu&#237;neo identificado por Doppler color entre la ACBL y el tejido de la VP en 23 de 59 (39%) VP-objetivo. La <xref ref-type="fig" rid="f3-body2">Figura 3</xref> muestra un derrame en la VPSD en la parte superior y en la VPSE en la parte inferior, que se correlaccion&#243; con la localizaci&#243;n del <italic>gap</italic> en el an&#225;lisis patol&#243;gico (<xref ref-type="fig" rid="f4-body2">Figura 4</xref>). La obtenci&#243;n del aislamiento completo de la VP fue significantemente m&#225;s com&#250;n en la ausencia de derrame del flujo sangu&#237;neo: 30 de 38 (79%) VP, comparadas con 8 de 23 (35%), cuando se document&#243; un derrame (p&lt;0,001). El criterio de la presencia de derrame del flujo sangu&#237;neo a trav&#233;s del USIC tuvo una especificidad del 86,8% y una sensibilidad del 71,5% para no obtenci&#243;n del aislamiento de la VP. El valor predictivo positivo para aislamiento incompleto fue del 75% y el valor predictivo negativo fue del 84,6%.</p>
      <fig id="f3-body2">
        <graphic xlink:href="1678-4170-abc-93-06-0666-00017-gf03-es.jpg"/></fig>
      <fig id="f4-body2">
        <graphic xlink:href="1678-4170-abc-93-06-0666-00017-gf04-es.jpg"/></fig>
      <p>Los 4 derrames visualizados en la VPSD estaban localizados en la parte inferior. De la misma forma, en el an&#225;lisis patol&#243;gico, el <italic>gap</italic> estaba presente en la parte inferior en las 3 VPSD. De forma similar, hubo 11 derrames visualizados en la VPSE: 10 en la parte inferior y 1 lateral. El examen macrosc&#243;pico mostr&#243; 9 <italic>gaps</italic> localizados en la parte inferior y ning&#250;n <italic>gap</italic> lateral.</p>
      <p>
        <bold>An&#225;lisis por regresi&#243;n log&#237;stica multivariada</bold>
      </p>
      <p>En el an&#225;lisis por regresi&#243;n log&#237;stica multivariada, la ausencia de derrame fue un predictor independiente de obtenci&#243;n de aislamiento de la VP. Cuando se analizaron esos hallazgos por an&#225;lisis multivariado con todos los otros par&#225;metros testados, incluyendo tiempo de aplicaci&#243;n, potencia, VP sometidos a la ablaci&#243;n, di&#225;metro y largura del bal&#243;n, la oportunidad de obtener el aislamiento de la VP fue significantemente mayor cuando el derrame no era visible al USIC (OR: 6.5, IC 95%: 1,4- 29,1). El aislamiento completo de la VP mostr&#243; una tendencia a ser independientemente m&#225;s com&#250;n con el uso de la potencia de 4,5 y 5,5 W/cm que con 3,5 W/cm (p = 0,076, OR: 5,3; IC 95%: 0,84- 33,0). Los vasos superiores, que fueron predictores del aislamiento el&#233;ctrico en el an&#225;lisis univariado, no alcanzaron significancia estad&#237;stica al nivel de 0,05 en el an&#225;lisis multivariado.</p>
      <p>
        <bold>Discusi&#243;n</bold>
      </p>
      <p>Pese a la &#233;nfasis de varios estudios sobre la importancia del contacto cat&#233;ter-tejido, cuando una corriente de radiofrecuencia se utiliza como fuente de energ&#237;a, esa informaci&#243;n se viene estudiando recientemente al utilizarse la energ&#237;a l&#225;ser, especialmente para la ablaci&#243;n circunferencial en las VP. El principal hallazgo del presente estudio fue el establecimiento de la utilidad del USIC para guiar la ablaci&#243;n de la VP, usando un nuevo tipo de ablaci&#243;n por cat&#233;ter-bal&#243;n de fibra &#243;ptica con energ&#237;a l&#225;ser. Observamos que el aislamiento el&#233;ctrico completo de la VP era significantemente m&#225;s com&#250;n cuando no hab&#237;a identificaci&#243;n de derrame del flujo sangu&#237;neo entre el tejido de la VP y la ablaci&#243;n por cat&#233;ter-bal&#243;n, lo que determina la importancia del contacto cat&#233;ter-bal&#243;n-tejido tambi&#233;n con el uso de la energ&#237;a l&#225;ser. Un buen contacto entre el bal&#243;n y el orificio de la VP es necesario para obtener una lesi&#243;n circunferencial<sup>14-17</sup>. Esas necesidades est&#225;n probablemente relacionadas a interacciones fotomec&#225;nicas y fotot&#233;rmicas entre la energ&#237;a l&#225;ser en el tejido y la transferencia de calor, lo que puede influenciarse por las caracter&#237;sticas de la circulaci&#243;n sangu&#237;nea y del tejido. El ultrasonido intracard&#237;aco usando un cat&#233;ter de ultrasonido con preparaci&#243;n de fase con punta multidireccional dirigible brinda una excelente visi&#243;n de las venas pulmonares y de los cat&#233;teres colocados dentro de esos vasos<sup>18-20</sup>. Se confirm&#243; la posici&#243;n del cat&#233;ter-bal&#243;n en la VP-objetivo antes de cada aplicaci&#243;n, y el uso del Doppler color mostr&#243; la obtenci&#243;n del contacto entre la pared de la VP y la superficie del cat&#233;ter-bal&#243;n. El USIC se ha mostrado muy &#250;til en la eletrofisiolog&#237;a intervencionista, incluyendo la cateterizaci&#243;n transeptal, visualizaci&#243;n de estructuras anat&#243;micas-objetivo y evaluaci&#243;n del contacto cat&#233;ter-tejido. Mangrum et al.<sup>20</sup> relataron la utilidad del USIC para guiar el aislamiento de la VP en seres humanos, mostrando la posibilidad de visualizar el posicionamiento del cat&#233;ter, el contacto con el tejido y la formaci&#243;n de la lesi&#243;n, pero usando el sistema rotacional mec&#225;nico<sup>20</sup>. Como se desarrollaron nuevas tecnolog&#237;as para aislamiento de la VP usando cat&#233;ter-bal&#243;n circunferencial, adicionamos la utilidad del Doppler de flujo colorido para ese tipo de procedimiento y, de acuerdo con nuestro conocimiento, este es el primer estudio que muestra la importancia del contacto con el tejido usando ablaci&#243;n con l&#225;ser.</p>
      <p>Desde el primer estudio relatado por Jais et al.<sup>21</sup> de un origen focal de la FA desencadeada por latidos ect&#243;picos originados en las VP, varios investigadores demostraron que la energ&#237;a de RF dirigida a esos focos elimina los latidos iniciantes de la VP y la FA parox&#237;stica<sup>21</sup>. Sin embargo, las tasas de recurrencia de la FA tras la ablaci&#243;n exitosa todav&#237;a son altas y complicaciones pueden desarrollarse despu&#233;s del procedimiento<sup>22,23</sup>. Tambi&#233;n se us&#243; la energ&#237;a de RF para aislar la VP al crear una lesi&#243;n circunferencial continua en el orificio. Alternativamente, se utilizaron diferentes fuentes de energ&#237;a para la ablaci&#243;n circunferencial a trav&#233;s de la energ&#237;a radial. Natale et al.<sup>7</sup> relataron el uso de cat&#233;ter-bal&#243;n de ultrasonido para aislar la VP a partir del atrio izquierdo, teniendo &#233;xito en el 60% de los casos<sup>7</sup>. En el presente estudio, se logr&#243; el aislamiento de la VP en el 64% de los casos tras una duraci&#243;n promedio de liberaci&#243;n de energia de 280 &#177; 177 seg., lo que es bastante similar a aqu&#233;lla utilizada por Natale et al.<sup>7</sup> Sin embargo, nuestras tasas de aislamiento de VP aumentaron en un 79% cuando no se observaron derrames del flujo sangu&#237;neo.</p>
      <p>
        <bold>Limitaciones del estudio</bold>
      </p>
      <p>Este estudio presenta varias limitaciones que se tendr&#225;n en cuenta. Aunque la imagen del USIC revel&#243; de forma clara el atrio izquierdo y la junci&#243;n de todas las venas en la VP, el n&#250;mero de venas inferiores sometidas a la ablaci&#243;n es muy peque&#241;o comparado al n&#250;mero de venas superiores, y no fuimos capaces de demostrar la misma utilidad para los dos tipos. Finalmente, estudios adicionales son necesarios para comparar el uso del USIC con otras nuevas tecnolog&#237;as desarrolladas para establecer el contacto cat&#233;ter-tejido. Otra potencial limitaci&#243;n fue la comparaci&#243;n entre el tama&#241;o de la VP y el tama&#241;o del bal&#243;n, que no se ajustaba. No obstante, el hecho del di&#225;metro promedio del bal&#243;n ser significantemente mayor despu&#233;s de inflado que el di&#225;metro de la VP en el orificio, mejora efectivamente el contacto cat&#233;ter-bal&#243;n-tejido.</p>
      <p>
        <bold>Implicaciones cl&#237;nicas</bold>
      </p>
      <p>El contacto cat&#233;ter-tejido revel&#243; ser importante tambi&#233;n para la ablaci&#243;n circunferencial con l&#225;ser usando el cat&#233;ter-bal&#243;n. Para ese prop&#243;sito, el ultrasonido intracard&#237;aco (USIC) puede ser &#250;til al mostrar el derrame del flujo sangu&#237;neo durante la liberaci&#243;n de energ&#237;a, lo que aumenta la posibilidad de alcanzar el aislamiento completo de la VP. En consecuencia, el uso del USIC podr&#237;a evitar la aplicaci&#243;n ineficaz de energ&#237;a durante la ablaci&#243;n circunferencial de la VP y eso disminuir&#237;a el riesgo de estenosis de la VP.</p>
      <p>
        <bold>Potencial Conflicto de Intereses</bold>
      </p>
      <p>Declaro no haber conflicto de intereses pertinentes.</p>
      <p>
        <bold>Fuentes de Financiaci&#243;n</bold>
      </p>
      <p>El presente estudio no tuvo fuentes de financiaci&#243;n externas.</p>
      <p>
        <bold>Vinculaci&#243;n Acad&#233;mica</bold>
      </p>
      <p>Este art&#237;culo forma parte de la tesis de postdoctorado de Luiz Roberto Leite de la Silva, por la Mayo Clinic Foundation.</p>
      <p>
        <bold>Referencias</bold>
      </p>
    </body>
  </sub-article>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Articles</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Utility of intracardiac ultrasound imaging to guide pulmonary vein ablation using laser balloon catheter</article-title>
      </title-group>
      <abstract xml:lang="en">
        <p>BACKGROUND: Pulmonary vein isolation (PVI) with balloon catheter has been used as the endpoint for AF ablation. OBJECTIVE: To determine the usefulness of intracardiac ultrasound (ICUS) to guide PVI using laser balloon catheter. METHODS: 59 PVs were ablated in 27 dogs. Doppler imaging was used to identify blood flow leaks between PV and balloon. After each energy delivery, the circular mapping catheter was repositioned to check if isolation had been achieved. The leak position was then correlated with the gap position at the pathological study. Multivariate logistic regression analysis was undertaken. RESULTS: 59 PV were ablated. Mean burn time was 279&#177;177 sec, mean balloon diameter was 23&#177;3 mm, and mean balloon length was 25&#177;4 mm. Complete isolation was achieved in 38/59 (64%) cases, and it was significantly more common when there was no leak: [30/38 (79%) versus 8/23 (35%), p&lt;0.001]. This occurred regardless of time of laser application (302&#177;223 sec. vs. 266&#177;148 sec., p=ns), laser power (3.5 W/cm, 4.5 W/cm, and 5.5 W/cm), balloon diameter (24&#177; 3 mm vs. 22&#177; 3 mm, p=ns) and length (27&#177;4 mm vs. 24&#177;4mm, p=ns). The positive predictive value for predicting incomplete isolation was 65% and the negative predictive value was 83%. CONCLUSION: An identifiable leak between PV and the LBA device seen at the ICUS is predictive of lower PV isolation rates. ICUS may be useful for leak detection to avoid ineffective energy application during circumferential PV ablation. This could also be helpful when other types of energy are used.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>ultrasonography</kwd>
        <kwd>catether ablation</kwd>
        <kwd>pulmonary veins</kwd>
        <kwd>balloon dilatation</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>ORIGINAL ARTICLE</bold>
      </p>
      <p>
        <fn id="top-body3">
          <label>
            <bold>Utility of intracardiac ultrasound imaging to guide pulmonary vein ablation using laser balloon catheter</bold>
          </label>
          <p>
            <bold>Luiz Leite; Wilber Su; Susan B. Johnson; Mark Milton; Benhur Henz; Alvaro Sarabanda; Simone N. Santos; Douglas L. Packer</bold>
          </p>
        </fn>
      </p>
      <p>Divis&#227;o de Doen&#231;as Cardiovasculares e Cl&#237;nica M&#233;dica - Mayo Clinic, Rochester, Minnesota, USA</p>
      <p> Mailing address</p>
      <p>
        <bold>ABSTRACT</bold>
      </p>
      <p><bold>BACKGROUND: </bold> Pulmonary vein isolation (PVI) with balloon catheter has been used as the endpoint for AF ablation.</p>
      <p><bold>OBJECTIVE:</bold> To determine the usefulness of intracardiac ultrasound (ICUS) to guide PVI using laser balloon catheter.</p>
      <p><bold>METHODS:</bold> 59 PVs were ablated in 27 dogs. Doppler imaging was used to identify blood flow leaks between PV and balloon. After each energy delivery, the circular mapping catheter was repositioned to check if isolation had been achieved. The leak position was then correlated with the gap position at the pathological study. Multivariate logistic regression analysis was undertaken.</p>
      <p><bold>RESULTS: </bold> 59 PV were ablated. Mean burn time was 279&#177;177 sec, mean balloon diameter was 23&#177;3 mm, and mean balloon length was 25&#177;4 mm. Complete isolation was achieved in 38/59 (64%) cases, and it was significantly more common when there was no leak: [30/38 (79%) versus 8/23 (35%), p&lt;0.001]. This occurred regardless of time of laser application (302&#177;223 sec. vs. 266&#177;148 sec., p=ns), laser power (3.5 W/cm, 4.5 W/cm, and 5.5 W/cm), balloon diameter (24&#177; 3 mm vs. 22&#177; 3 mm, p=ns) and length (27&#177;4 mm vs. 24&#177;4mm, p=ns). The positive predictive value for predicting incomplete isolation was 65% and the negative predictive value was 83%.</p>
      <p><bold>CONCLUSION:</bold> An identifiable leak between PV and the LBA device seen at the ICUS is predictive of lower PV isolation rates. ICUS may be useful for leak detection to avoid ineffective energy application during circumferential PV ablation. This could also be helpful when other types of energy are used.</p>
      <p><bold>Key words:</bold> Ultrasonography; catether ablation; pulmonary veins; balloon dilatation.</p>
      <p>
        <bold>Introduction</bold>
      </p>
      <p>Atrial Fibrillation (AF) is one of the most common cardiac arrhythmias in clinical practice. Recently, several authors have reported that most paroxysmal AF can be initiated by firing ectopic foci from the pulmonary veins (PV)<sup>1-3</sup>. Despite termination of AF by eliminating these PV foci with radiofrequency catheter ablation (RFCA), recurrence rates of AF are high and some complications are a cause of concern<sup>4-6</sup>.</p>
      <p>In order to decrease recurrence of AF and avoid PV stenosis, PV isolation has been proposed as the endpoint for ablation, either with RF or alternative energy such as ultrasound and laser<sup>7-9</sup>. A novel laser balloon catheter ablation (LBCA) strategy was recently developed to electrically isolate the PV from the left atrium by creating circumferential lesions at the PV ostium<sup>10</sup>. Intracardiac ultrasound (ICUS) has been applied in the electrophysiology laboratory to guide RF ablation lesions, to perform transseptal puncture, and to guide catheter placement during AF ablation<sup>11-13</sup>. Although the usefulness of ICUS is still unclear in LBCA, it may help to determine catheter position and adequate tissue contact. Therefore, the purpose of the present study was to determine the role of ICUS in guiding PV isolation with LBAC and to assess the role of direct tissue contact in lesion formation and PV isolation.</p>
      <p>
        <bold>Methods</bold>
      </p>
      <p>
        <bold>Animal preparation</bold>
      </p>
      <p>The study protocol was approved by the Mayo Foundation - Institutional Animal Care and Use Committee, and all procedures were followed in accordance with institutional guidelines. Twenty-seven male mongrel dogs (weight, 30 to 40 kg) were anesthetized with nembutal (30 mg/kg) in acute studies or brevital (12.5 mg/kg) followed by isoflurane (1-3%) in chronic studies. Mechanical ventilation was provided during the procedures with to supplement oxygen. After ECG monitoring was established, venous access was obtained percutaneously or by accessing the right and left external jugular veins using 8-12 Fr sheaths. The right femoral vein was cannulated with a 16 Fr sheath for subsequent transseptal sheath access, as previously described<sup>12</sup>. Briefly, left atrial transseptal puncture was performed under intracardiac ultrasound and fluoroscopic guidance using a standard Mullins transseptal sheath and a Brockenbrough needle. Finally, an 8 Fr sheath was used to cannulate the right femoral artery for arterial pressure monitoring. Heparin was given to keep ACT &gt; 300 seconds.</p>
      <p>
        <bold>Intracardiac ultrasound imaging</bold>
      </p>
      <p>Intracardiac ultrasound was performed using a 10-Fr 5.5-10 MHz, phased-array ultrasound catheter with a multi-directional steerable tip (Acunav; Acuson, Mountain View, CA, USA) with Doppler capabilities. Details of catheter design have been previously reported<sup>11,14,15</sup>. The ultrasound catheter was advanced via a 12-French sheath in the external jugular vein and positioned in the high right atrium, from where it was possible to visualize the left atrium and the PV, and the LBC position. The catheter was then coupled to a Sequoia ultrasound imaging platform (Acuson, Mountain View, CA, USA). Before laser energy application, ICUS with color Doppler was used to assess the presence of a blood flow leak between the targeted PV and the LBCA to optimize the balloon-tissue contact. Furthermore, diameter (anterior-posterior and medium-lateral), circumferentiality, and area of the left atrium and PV ostium diameter and Doppler flow velocities were measured before and after ablation using ICUS.</p>
      <p>
        <bold>Electrophysiology study and laser balloon ablation</bold>
      </p>
      <p>A 7 Fr, deflectable, circular mapping catheter was inserted via a transseptal sheath and positioned into the PV targeted for recording and pacing. A 7 Fr, 10-pole catheter was also inserted via the jugular access and positioned into the coronary sinus. Electrograms were displayed simultaneously with surface ECG and recorded on a multichannel system (Prucka Cardiolab System, GE Medical Systems, Waukesha, WI, USA). PV isolation was evaluated during normal sinus rhythm and distal coronary sinus pacing at twice the diastolic threshold using a circular mapping catheter (<xref ref-type="fig" rid="f1-body3">Figure 1</xref>).</p>
      <fig id="f1-body3">
        <graphic xlink:href="1678-4170-abc-93-06-0666-00017-gf01-en.jpg"/></fig>
      <p>Laser balloon catheter ablation was performed next to the PV orifice via a transseptal approach under fluoroscopic and ICUS guidance. Because of the initial experience with this new balloon catheter, superior PVs were preferably selected for ablation with this protocol. After positioning the laser balloon tip in the target PV, the ablation balloon was inflated to a pressure of 1 ATM with D<sub>2</sub>O/radiopaque contrast mix. Two different balloon ring sizes were available: 17 mm and 22 mm (CardioFocus). Both the balloon length and diameter were measured by ICUS after inflated. Laser energy was delivered at 3.5 W/cm, 4.5 W/cm, and at 5.5 W/cm for 120 to 720 sec. The ablation system was selectively coupled to the output of the laser generator at 980nm continuous wave and transferred to the ablation balloon via fiber optics. Power and time during ablation was recorded. The pulmonary veins were selected for ablation and the laser catheter was advanced through a 12 Fr sheath positioned at the ostium of the vein and the ablation surface was positioned against the tissue in the desired area of the pulmonary vein. The fluoroscopic view, light reflectance, contact sensed and ultrasound position of the catheter array was used to achieve the best position. An activation recording was made before and after each lesion was created using a circumferential mapping catheter. If the fluoroscopic or ultrasound position information indicated that the contact was grossly sub-optimal, the catheter was repositioned. Laser energy was delivered according to established delivery paradigms. The delivery duration was 120 seconds. Following energy delivery, electrograms and pacing thresholds were repeated. This procedure was repeated up to 6 times or when PV isolation was observed. Longitudinal and circular mapping of the vein was used to assess entrance block during NSR, RA and DCS pacing.</p>
      <p>
        <bold>Histological characterization of the ablation lesions</bold>
      </p>
      <p>After each ablation session, animals were returned to the <italic>vivarium</italic> for post-procedure monitoring and 30 days of the maturation phase. After that period, animals were again deeply anesthetized with nembutal. Ventricular fibrillation was then induced with high burst pacing and the animals were exsanguinated. A right lateral thoracotomy was performed and the entire heart-lung preparation was removed with the intact pericardium. A gross examination was performed, during which endocardial and epicardial tissue surfaces were reviewed for verification of lack of continuity of the ablation lesions (gap). The relationship between these sites and any apparent gaps in the ablation ring at the orifice of the pulmonary vein was also established. The gap location was then correlated with ultrasound findings.</p>
      <p>
        <bold>Statistical analysis</bold>
      </p>
      <p>Continuous data are presented as mean &#177; SD, unless otherwise stated. Differences between the presence and absence of PV isolation were performed with Student's <italic>t</italic> test for continuous variables. For categorical variables, Chi-square or Fisher's exact test were used when appropriate. Multivariate logistic regression analysis was performed to determine which of the following factors were independently associated with PV isolation: ablated PV, delivered power, and laser energy duration, presence of leak identified by ICUS, balloon diameter and length for successful PV isolation. A forward stepwise (likelihood ratio) method was used to determine the significant predictors of achieving complete PV isolation, considering the elimination criteria of P &gt; 0.10). Confidence intervals at 95% were calculated for odds ratio following logistic regression. A P value <underline>&lt;</underline> 0.05 was considered statistically significant. The positive and negative predictive accuracy of the presence of leaks was calculated for the achievement of successful PV isolation.</p>
      <p>
        <bold>Results</bold>
      </p>
      <p>The transseptal approach was successfully accomplished in all dogs, and the balloon catheter and the circular mapping catheter were positioned in the targeted PV. Fifty-nine PV were ablated in 27 adults mongrel dogs, including 23 right superior PV (RSPV), 27 left superior PV (LSPV), 8 left inferior PV (LIPV), and 1 right inferior PV (RIPV). Seventeen PV were acutely ablated in 7 dogs and 42 PV were chronically ablated in 20 dogs. PV potentials were observed in all veins before laser ablation, during both normal sinus rhythm and distal coronary sinus pacing.</p>
      <p>
        <bold>Laser balloon ablation and PV isolation</bold>
      </p>
      <p>The mean total ablation time was 275 &#177; 88 minutes, and the mean fluoroscopy time was 83 &#177; 18 minutes. Of a total of 59 ablated PV, 18, 30% (4 RSPV, 7 LSPV, 6 LIPV, and 1 RIPV) were ablated at 3.5 W/cm. Twenty-four, 40% PV (11 RSPV, 12 LSPV, 1 and LIPV) were ablated at 4.5 W/cm, and 17, 30% (8 RSPV, 8 LSPV, and 1 LIPV) were ablated at 5.5 W/cm. In one dog 2 separate RSPV branches were ablated. The mean duration of energy applied was 279 &#177; 177 sec. Complete PV isolation was achieved in 38/59 (64%) of the ablated PV. There was no difference in mean duration of energy applied when PV isolation was achieved (266 &#177; 148 sec) compared to those in which isolation was not achieved (303 &#177; 223 sec). The rate of PV isolation was significantly higher (p=0.002) using a power of 5.5 W/cm (88.9%) and 4.5 W/cm (64.3%) than with 3.5 W/cm (30.8%). There was no difference between 4.5 and 5.5 W/cm.</p>
      <p>
        <bold>Intracardiac ultrasound findings and pathological data</bold>
      </p>
      <p>With the ICUS catheter tip located at the right atrium (RA), near the junction of the superior vena cava (SVC) and the RA, it was possible to visualize the left atrium, determine location and diameter of all PV ostia, and measure PV Doppler flow velocities, LBCA measurements and leaks between PV and LBCA. <xref ref-type="fig" rid="en_17f2-body3">Figure 2</xref> depicts the LBCA deployment at the PV and how the length and diameter were measured. After being inflated, the mean LBCA diameter was 23.1 &#177; 3.0 mm, and the mean length was 25.6 &#177; 4.4 mm. There was no difference in the LBCA diameter and length whether PV isolation was achieved or not (24.1 &#177; 3.3 mm <italic>vs</italic>. 22.9 &#177; 3.2 mm; 27.2 &#177; 4.1 mm <italic>vs</italic>. 24.8 &#177; 4.3 mm, respectively). The mean PV diameter at the orifice was 14.1 &#177; 2.8 mm, and there was no difference between complete and incomplete isolation (14.4 &#177; 2.9 <italic>vs</italic>. 13.6 &#177; 2.5, <italic>p</italic> = 0.33). The difference between the PV diameter at the orifice and the balloon diameter after being inflated shows that there was a significant distension of the PV wall during laser energy delivery.</p>
      <p content-type="asset">
        <fig id="en_17f2-body3">
          <graphic xlink:href="1678-4170-abc-93-06-0666-00017-gf02-en.jpg"/></fig>
      </p>
      <p>Color Doppler blood flow leak between the LBCA and the PV tissue was detected in 23 out of 59 (39%) targeted PV. <xref ref-type="fig" rid="f3-body3">Figure 3</xref> shows a leak in the RSPV superiorly and in the LSPV inferiorly, which were correlated with the location of the gap in the pathological analysis (<xref ref-type="fig" rid="f4-body3">Figure 4</xref>). Achievement of complete PV isolation was significantly more common in the absence of blood flow leak: 30 out of 38 (79%) PV, compared to 8 of 23 (35%) PV when a leak was documented (p&lt;0.001). The presence of blood flow leak criterion by ICUS had 86.8% specificity and 71.5% sensitivity for not achieving PV isolation. The positive value for predicting incomplete isolation was 75% and the negative predictive value was 84.6%.</p>
      <fig id="f3-body3">
        <graphic xlink:href="1678-4170-abc-93-06-0666-00017-gf03-en.jpg"/></fig>
      <fig id="f4-body3">
        <graphic xlink:href="1678-4170-abc-93-06-0666-00017-gf04-en.jpg"/></fig>
      <p>All 4 leaks visualized in the RSPV were located inferiorly. Additionally, at the pathological analysis, a gap was present inferiorly in 3 RSPVs. Similarly, 11 leaks were visualized in the LSPV: 10 inferiorly and 1 laterally. The gross pathology assessment showed 9 gaps located inferiorly and no lateral gaps.</p>
      <p>
        <italic>
          <bold>Multivariate logistic regression analysis</bold>
        </italic>
      </p>
      <p>At the multivariate logistic regression analysis, the absence of blood flow leak was an independent predictor of achieving PV isolation. When these findings were run in multivariate analysis with all other tested parameters, including: time of application, laser power, ablated PV, balloon diameter and length, the chance of achieving PV isolation was significantly greater when a leak was not visible at the ICUS (OR: 6.5, 95% CI: 1.4; 29.1). Complete PV isolation tended to be independently more common when the laser power used was 4.5 and 5.5 W/cm than with 3.5 W/cm (p = 0.076, OR: 5.3, 95% CI: 0.84; 33.0). Superior vessels, which were a predictor of electrical isolation at the univariate analysis, did not reach significance at the level of 0.05 at the multivariate analysis.</p>
      <p>
        <bold>Discussion</bold>
      </p>
      <p>Despite the emphasis given by several studies on the importance of catheter-tissue contact when radiofrequency current is used as energy source, this information has been recently studied when using laser energy, especially for circumferential ablation in the pulmonary veins. The main finding provided by the present study was to establish the usefulness of ICUS to guide PV ablation using a new fiber-optic balloon-catheter ablation with laser energy. We observed that complete electrical PV isolation was significantly more common when no blood flow leaks were identified between PV tissue and balloon catheter ablation, which determines the importance of catheter-balloon tissue contact also with laser energy. Good contact between the balloon and the PV orifice is necessary to obtain a circumferential lesion<sup>14-17</sup>. These requirements are probably related to photothermal and photomechanical interactions between laser energy on the tissue and heat transfer, which can be influenced by blood stream and tissue characteristics. Intracardiac ultrasound using phased-array ultrasound catheter with a multi-directional steerable tip provides an excellent view of the pulmonary veins and of the catheters placed within these vessels<sup>18-20</sup>. The balloon catheter position in the targeted PV was confirmed before each single application, and the use of the color flow Doppler yielded the determination of the contact between the PV wall and the catheter balloon surface. The intracardiac ultrasound has shown to be very useful in interventional electrophysiology, including transseptal catheterization, visualization of targeted anatomical structures and evaluation of catheter-tissue contact. Mangrum et al<sup>20</sup> reported the usefulness of ICUS for guiding PV isolation in humans, showing the possibility of visualizing the catheter positioning, tissue contact and lesion formation, but using the mechanical rotational system<sup>20</sup>. As new technologies for PV isolation using circumferential balloon catheter have been developed, we added the usefulness of color Doppler flow to this kind of procedure, and to the best of our knowledge, this is the first report showing the importance of tissue contact using laser ablation.</p>
      <p>Since the first report by Jais et al.<sup>21</sup>, of a focal origin of AF triggering by ectopic beats from the PV, several investigators have demonstrated that radiofrequency energy delivered at these foci eliminates the PV-initiated beats and paroxysmal AF<sup>21</sup>. However, recurrence rates of AF after successful ablation is still high and complications may ensue after this procedure<sup>22,23</sup>. Radiofrequency energy has also been used to isolate PV by creating a continuous circumferential lesion at the orifice. Alternatively, different energy sources have been used for circumferential ablation through radial energy delivery. Natale et al<sup>7</sup> reported the use of ultrasound balloon catheter to isolate PV from the left atrium, which was accomplished in 60%<sup>7</sup>. In the present study, PV isolation was achieved in 64% after mean energy delivery duration of 280 &#177; 177 sec, which is very similar to that reported by Natale et al.<sup>7</sup> However, our rates of PV isolation increased to 79% when no blood flow leaks were observed.</p>
      <p>
        <italic>
          <bold>Study limitations</bold>
        </italic>
      </p>
      <p>This study has several limitations to be considered. Although the ICUS imaging showed very well the left atrium and PV junction of all veins, the number of inferior veins ablated is very small when compared to the superior veins, and we were not able to prove the same usefulness for both. Finally, further studies are necessary to compare the use of the ICUS with other new technologies developed to establish catheter-tissue contact. Another potential limitation was the comparison between PV size and the balloon size, which did not fit. However, as the mean balloon size diameter, after inflated, was significantly greater than the PV diameter at the orifice, this would actually improve the balloon catheter-tissue contact.</p>
      <p>
        <italic>
          <bold>Clinical implications</bold>
        </italic>
      </p>
      <p>The catheter-tissue contact showed to be important also for circumferential laser ablation using balloon catheter. For this purpose, intracardiac ultrasound may be useful in showing blood flow leaks during energy delivery, which decreases the possibility of achieving complete PV isolation. As a consequence, the use of ICUS would avoid ineffective energy application during circumferential PV ablation and would decrease the risk of PV stenosis.</p>
      <p>
        <bold>Potential Conflict of Interest</bold>
      </p>
      <p>No potential conflict of interest relevant to this article was reported.</p>
      <p>
        <bold>Sources of Funding</bold>
      </p>
      <p>There were no external funding sources for this study.</p>
      <p>
        <bold>Study Association</bold>
      </p>
      <p>This article is part of the thesis of post doctoral submitted by Luiz Roberto Leite da Silva, from Mayo Clinic Foundation.</p>
      <p>
        <bold>References</bold>
      </p>
    </body>