<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">5RwBjXc7P6CDK4BZ6TNFpMd</article-id>
      <article-id pub-id-type="other">00002</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2009000100002</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(09)09200102</article-id>
      <article-id pub-id-type="doi">10.1590/S0066-782X2009000100002</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigos Originais</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Implante de stents farmacol&#243;gicos na art&#233;ria descendente anterior: indicadores de eventos tardios</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Santos</surname>
            <given-names>Marcelo de Freitas</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Tarbine</surname>
            <given-names>Sergio Gustavo</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Costantini</surname>
            <given-names>Costantino Ortiz</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Oliveira</surname>
            <given-names>Maria do Rocio Peixoto</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Bubna</surname>
            <given-names>Marcos Henrique</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Guarita-Souza</surname>
            <given-names>Luiz Cesar</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Braga</surname>
            <given-names>Chiu Yun Yu</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Stella</surname>
            <given-names>Francisco de Paula</given-names>
          </name>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Costantini</surname>
            <given-names>Costantino Roberto</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Rivetti</surname>
            <given-names>Luiz Antonio</given-names>
          </name>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <institution content-type="orgname">Hospital Cardiol&#243;gico Costantini</institution>
        <country country="BR">Brasil</country>
      </aff>
      <aff id="aff02">
        <addr-line>
          <named-content content-type="city">S&#227;o Paulo</named-content>
          <named-content content-type="state">S&#227;o Paulo</named-content>
        </addr-line>
        <institution content-type="orgname">Santa Casa de Miseric&#243;rdia de S&#227;o Paulo</institution>
        <institution content-type="orgdiv1">Faculdade de Ci&#234;ncias M&#233;dicas </institution>
        <country country="BR">Brazil</country>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>01</month>
        <year>2009</year>
      </pub-date>
      <volume>92</volume>
      <issue>1</issue>
      <fpage>2</fpage>
      <lpage>9</lpage>
      <history>
        <date date-type="rev-recd">
          <day>04</day>
          <month>11</month>
          <year>2007</year>
        </date>
        <date date-type="received">
          <day>12</day>
          <month>03</month>
          <year>2007</year>
        </date>
        <date date-type="accepted">
          <day>14</day>
          <month>04</month>
          <year>2008</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <abstract>
        <p>FUNDAMENTO: A efic&#225;cia dos stents farmacol&#243;gicos em reduzir os &#237;ndices de eventos card&#237;acos n&#227;o &#233; uniforme a todos os subgrupos de les&#245;es ou pacientes. OBJETIVO: Avaliar a evolu&#231;&#227;o cl&#237;nica tardia dos pacientes submetidos a implante de stents farmacol&#243;gicos nas les&#245;es ateroscler&#243;ticas da art&#233;ria descendente anterior e identificar, entre as caracter&#237;sticas cl&#237;nicas, angiogr&#225;ficas e do ultra-som intravascular, quais as que permitem predizer risco de eventos card&#237;acos. M&#201;TODOS: De maio de 2002 a agosto de 2005, foram tratados 205 pacientes com implante de 236 stents farmacol&#243;gicos guiados pelo ultra-som intravascular. RESULTADOS: Com um acompanhamento m&#233;dio de 711 dias, a taxa de trombose do stent foi de 0,48%, a mesma observada para infarto agudo do mioc&#225;rdio ou cirurgia de revasculariza&#231;&#227;o. A taxa de revasculariza&#231;&#227;o da les&#227;o tratada foi de 7,31% e a taxa global de eventos de 10,24%. Os indicadores de eventos, conforme an&#225;lise multivariada, foram o implante de mais de um stent na mesma art&#233;ria, les&#245;es conc&#234;ntricas e &#225;rea m&#237;nima intra-stent medida pelo ultra-som intravascular menor que 3,88 mm&#178;. CONCLUS&#195;O: Baseados nos dados obtidos, conclu&#237;mos que a revasculariza&#231;&#227;o da art&#233;ria descendente anterior com implante de stents farmacol&#243;gicos escolhidos e otimizados pelo ultra-som intravascular apresenta baixo &#237;ndice de eventos tardios. O implante de dois stents farmacol&#243;gicos para o tratamento das les&#245;es longas foi o principal fator independente para a ocorr&#234;ncia de eventos tardios. A &#225;rea luminal final maior que 3,88 mm&#178; obtidos nos segmentos de pequenos di&#226;metros de refer&#234;ncia &#233; um indicador independente de evolu&#231;&#227;o livre de eventos.</p>
      </abstract>
      <kwd-group xml:lang="pt" kwd-group-type="author-generated">
        <kwd>Angioplastia transluminal</kwd>
        <kwd>contenedores</kwd>
        <kwd>ultra-som</kwd>
      </kwd-group>
      <pub-date publication-format="electronic" date-type="pub">
        <day>12</day>
        <month>02</month>
        <year>2009</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>
      <bold>ARTIGO ORIGINAL</bold>
    </p>
    <p>Implante de <italic><bold>stents</bold></italic> farmacol&#243;gicos na art&#233;ria descendente anterior. Indicadores de eventos tardios </p>
    <p>
      <bold>Marcelo de Freitas Santos<sup>I</sup>; Sergio Gustavo Tarbine<sup>I</sup>; Costantino Ortiz Costantini<sup>I</sup>; Maria do Rocio Peixoto Oliveira<sup>I</sup>; Marcos Henrique Bubna<sup>I</sup>; Luiz Cesar Guarita-Souza<sup>I</sup>; Chiu Yun Yu Braga<sup>I</sup>; Francisco de Paula Stella<sup>II</sup>; Costantino Roberto Costantini<sup>I</sup>; Luiz Antonio Rivetti<sup>II</sup></bold>
    </p>
    <p><sup>I</sup>Hospital Cardiol&#243;gico Costantini - Brasil </p>
    <p><sup>II</sup>Faculdade de Ci&#234;ncias M&#233;dicas da Santa Casa de S&#227;o Paulo, S&#227;o Paulo, SP - Brasil</p>
    <p>
      <xref ref-type="corresp" rid="back">Correspond&#234;ncia</xref>
    </p>
    <p>
      <bold>RESUMO</bold>
    </p>
    <p><bold>FUNDAMENTO:</bold> A efic&#225;cia dos <italic>stents</italic> farmacol&#243;gicos em reduzir os &#237;ndices de eventos card&#237;acos n&#227;o &#233; uniforme a todos os subgrupos de les&#245;es ou pacientes. </p>
    <p><bold>OBJETIVO:</bold> Avaliar a evolu&#231;&#227;o cl&#237;nica tardia dos pacientes submetidos a implante de <italic>stents</italic> farmacol&#243;gicos nas les&#245;es ateroscler&#243;ticas da art&#233;ria descendente anterior e identificar, entre as caracter&#237;sticas cl&#237;nicas, angiogr&#225;ficas e do ultra-som intravascular, quais as que permitem predizer risco de eventos card&#237;acos. </p>
    <p><bold>M&#201;TODOS:</bold> De maio de 2002 a agosto de 2005, foram tratados 205 pacientes com implante de 236 <italic>stents</italic> farmacol&#243;gicos guiados pelo ultra-som intravascular. </p>
    <p><bold>RESULTADOS:</bold> Com um acompanhamento m&#233;dio de 711 dias, a taxa de trombose do <italic>stent</italic> foi de 0,48%, a mesma observada para infarto agudo do mioc&#225;rdio ou cirurgia de revasculariza&#231;&#227;o. A taxa de revasculariza&#231;&#227;o da les&#227;o tratada foi de 7,31% e a taxa global de eventos de 10,24%. Os indicadores de eventos, conforme an&#225;lise multivariada, foram o implante de mais de um <italic>stent</italic> na mesma art&#233;ria, les&#245;es conc&#234;ntricas e &#225;rea m&#237;nima intra-<italic>stent</italic> medida pelo ultra-som intravascular menor que 3,88 mm<sup>2</sup>. </p>
    <p><bold>CONCLUS&#195;O:</bold> Baseados nos dados obtidos, conclu&#237;mos que a revasculariza&#231;&#227;o da art&#233;ria descendente anterior com implante de <italic>stents</italic> farmacol&#243;gicos escolhidos e otimizados pelo ultra-som intravascular apresenta baixo &#237;ndice de eventos tardios. O implante de dois <italic>stents</italic> farmacol&#243;gicos para o tratamento das les&#245;es longas foi o principal fator independente para a ocorr&#234;ncia de eventos tardios. A &#225;rea luminal final maior que 3,88 mm<sup>2</sup> obtidos nos segmentos de pequenos di&#226;metros de refer&#234;ncia &#233; um indicador independente de evolu&#231;&#227;o livre de eventos.</p>
    <p><bold>Palavras-chave:</bold> Angioplastia transluminal, contenedores, ultra-som.</p>
    <p>
      <bold>Introdu&#231;&#227;o</bold>
    </p>
    <p>Os <italic>stents</italic> farmacol&#243;gicos com agentes antiproliferativos t&#234;m como alvo a supress&#227;o da hiperplasia neo-intimal. As a&#231;&#245;es farmacol&#243;gicas desses agentes bloqueiam diretamente o ciclo celular na sua fase inicial (a&#231;&#227;o citost&#225;tica) ou na sua fase final (a&#231;&#227;o citot&#243;xica). Os <italic>stents</italic> farmacol&#243;gicos com sirolimus (rapamicina) ou com paclitaxel - as pr&#243;teses farmacol&#243;gicas mais extensivamente estudadas com evolu&#231;&#227;o em longo prazo - t&#234;m apresentado significativa redu&#231;&#227;o dos eventos tardios, principalmente pela redu&#231;&#227;o da restenose, quando comparados aos <italic>stents</italic> n&#227;o-farmacol&#243;gicos (met&#225;licos)<sup>1-4</sup>.</p>
    <p>A boa evolu&#231;&#227;o da revasculariza&#231;&#227;o da art&#233;ria descendente anterior &#233; um indicador independente de sobrevida nos principais estudos cir&#250;rgicos comparativos de pacientes receptores ou n&#227;o de enxerto de art&#233;ria mam&#225;ria. Essa t&#233;cnica de revasculariza&#231;&#227;o &#233; indicada de modo extensivo principalmente nos pacientes com les&#245;es complexas na art&#233;ria descendente anterior - les&#245;es que envolvem os ramos diagonais, les&#245;es longas (&gt;20 mm), vasos finos (&lt;2,75 mm de di&#226;metro) ou por associa&#231;&#227;o com o diabete melito. Esses subgrupos foram inclu&#237;dos em muitos estudos randomizados para o uso dos <italic>stents</italic> farmacol&#243;gicos<sup>3,5-7</sup>, por&#233;m n&#227;o espec&#237;ficos &#224; art&#233;ria descendente anterior. O benef&#237;cio reconhecido dos <italic>stents</italic> farmacol&#243;gicos em grupos selecionados, nos diversos estudos randomizados j&#225; referidos, permite uma boa evolu&#231;&#227;o da revasculariza&#231;&#227;o da art&#233;ria descendente anterior, independentemente da complexidade da les&#227;o ateroscler&#243;tica ou da caracter&#237;stica cl&#237;nica presente.</p>
    <p>Alguns estudos sugerem que o uso de ultra-som intravascular, como m&#233;todo-guia do implante dos <italic>stents</italic> n&#227;o-farmacol&#243;gicos, poderia reduzir as taxas de restenose tardia em determinados subgrupos de pacientes<sup>8</sup>. Quanto &#224; participa&#231;&#227;o desse recurso como guia no implante de <italic>stents</italic> farmacol&#243;gicos, entretanto, as pesquisas publicadas t&#234;m sido ainda insuficientes.</p>
    <p>S&#227;o os seguintes os objetivos desta pesquisa:</p>
    <list list-type="bullet">
      <list-item>
        <p>Avaliar a evolu&#231;&#227;o cl&#237;nica (eventos card&#237;acos) tardia dos pacientes submetidos a tratamento de les&#245;es ateroscler&#243;ticas da art&#233;ria descendente anterior com implante de </p>
        <p><italic>stents</italic> farmacol&#243;gicos.</p>
      </list-item>
      <list-item>
        <p>Identificar, entre as caracter&#237;sticas cl&#237;nicas, angiogr&#225;ficas e do ultra-som, quais as que permitem indicar risco de eventos card&#237;acos.</p>
      </list-item>
    </list>
    <p>
      <bold>M&#233;todos</bold>
    </p>
    <p>
      <bold>Avalia&#231;&#227;o pr&#233;-procedimento</bold>
    </p>
    <p>Todos os pacientes submetidos ao procedimento intervencionista apresentaram previamente uma cinecoronariografia diagn&#243;stica. No dia que antecedeu o procedimento, seguindo uma padroniza&#231;&#227;o do servi&#231;o, foram submetidos &#224; avalia&#231;&#227;o cl&#237;nica, eletrocardiogr&#225;fica e laboratorial - hemograma, creatinina e glicemia de jejum. A medica&#231;&#227;o prescrita foi aspirina (200 mg), clopidogrel (300 mg) e uma estatina de escolha do m&#233;dico assistente. Foram mantidas as outras medica&#231;&#245;es habituais do paciente, com exce&#231;&#227;o dos anticoagulantes e hipoglicemiantes orais. Jejum foi prescrito para as seis horas anteriores ao encaminhamento &#224; sala de hemodin&#226;mica.</p>
    <p>Antes da libera&#231;&#227;o dos <italic>stents</italic> farmacol&#243;gicos, fez-se a pr&#233;-dilata&#231;&#227;o das les&#245;es mediante o uso dos bal&#245;es convencionais com di&#226;metro entre 2,0 mm e 3,5 mm ou com t&#233;cnicas ateroabrasivas. Implante direto sem pr&#233;-dilata&#231;&#227;o foi feito quando se observou que havia condi&#231;&#245;es favor&#225;veis para a sua expans&#227;o.</p>
    <p>Os <italic>stents</italic> farmacol&#243;gicos foram liberados com press&#227;o entre 4 e 18 atm, e a dilata&#231;&#227;o complementar foi realizada com bal&#227;o de comprimento menor que a extens&#227;o do <italic>stent</italic>, o que permite a expans&#227;o deste sem inj&#250;ria dos seus bordos. Ap&#243;s resultado angiogr&#225;fico adequado da libera&#231;&#227;o do <italic>stent</italic> (les&#227;o residual menor que 10% pela an&#225;lise subjetiva do operador) e com base nas medidas obtidas p&#243;s-implante com ultra-som intravascular, fez-se avalia&#231;&#227;o da necessidade ou n&#227;o de novas dilata&#231;&#245;es.</p>
    <p>
      <bold>Ultra-som intravascular</bold>
    </p>
    <p>Foi usado cateter transdutor Atlantis de 40 MHz, que cont&#233;m na extremidade um espelho angulado rotat&#243;rio com velocidade de 1.800 rpm na frente do cristal emissor das ondas sonoras. As ondas sonoras emitidas eram recebidas e transformadas em imagens do interior do vaso pelo aparelho de ultra-som Galaxy ou Clearview, da empresa Boston Scientific, que as disponibilizava para a tela em tempo real e as armazenava em fita de videocassete. A an&#225;lise pr&#233;-implante do <italic>stent</italic> farmacol&#243;gico tinha como objetivo avaliar os di&#226;metros de refer&#234;ncia proximais e distais, bem como a extens&#227;o da placa ateroscler&#243;tica para a sele&#231;&#227;o ideal do <italic>stent</italic> farmacol&#243;gico (tanto no di&#226;metro como na extens&#227;o). No controle p&#243;s-implante, buscou-se boa aposi&#231;&#227;o das hastes dos <italic>stents</italic> &#224; parede do vaso e correla&#231;&#227;o entre &#225;reas luminais m&#237;nimas intra-<italic>stent</italic> e as &#225;reas de refer&#234;ncia.</p>
    <p>Os c&#225;lculos da avalia&#231;&#227;o do IVUS p&#243;s-implante foram realizados com o programa Echoplaque 2, vers&#227;o 2.5.x, da empresa Indec Systems Inc, Calif&#243;rnia, USA.</p>
    <p>
      <bold>Acompanhamento cl&#237;nico</bold>
    </p>
    <p>Os pacientes foram acompanhados por seus cl&#237;nicos durante todo o processo. Nos meses de maio e junho de 2006, fez-se levantamento, por meio de contacto telef&#244;nico, dos eventos card&#237;acos maiores.</p>
    <p>Deu-se &#234;nfase aos eventos tardios:</p>
    <list list-type="bullet">
      <list-item>
        <p>&#243;bito;</p>
      </list-item>
      <list-item>
        <p>infarto agudo do mioc&#225;rdio;</p>
      </list-item>
      <list-item>
        <p>trombose do </p>
        <p><italic>stent</italic> farmacol&#243;gico, definida como oclus&#227;o angiogr&#225;fica aguda ou tardia dos </p>
        <p><italic>stents</italic>;</p>
      </list-item>
      <list-item>
        <p>taxa de revasculariza&#231;&#227;o da les&#227;o tratada (TLR) caracterizada como qualquer nova revasculariza&#231;&#227;o cir&#250;rgica ou percut&#226;nea decorrente de uma restenose angiogr&#225;fica das les&#245;es previamente dilatadas;</p>
      </list-item>
      <list-item>
        <p>taxa de revasculariza&#231;&#227;o do vaso alvo (TVR) caracterizada como qualquer nova revasculariza&#231;&#227;o cir&#250;rgica ou percut&#226;nea decorrente de restenose ou de uma nova les&#227;o no vaso previamente tratado.</p>
      </list-item>
    </list>
    <p>
      <bold>Crit&#233;rios de inclus&#227;o</bold>
    </p>
    <p>Participaram do estudo pacientes com idade superior a 18 anos, independentemente do sexo, de fatores de risco e da s&#237;ndrome cl&#237;nica no momento da admiss&#227;o, com indica&#231;&#227;o de tratamento intervencionista somente da art&#233;ria descendente anterior associada ou n&#227;o aos ramos septais ou diagonais. Em todos os pacientes, a fra&#231;&#227;o de eje&#231;&#227;o do ventr&#237;culo esquerdo era maior que 30%, e o di&#226;metro de refer&#234;ncia da art&#233;ria descendente anterior maior ou igual a 2,25 mm. Foram englobados os pacientes uniarterial ou multiarterial, com todos os tipos de les&#227;o ateroscler&#243;tica "de novo" (nomenclatura da for&#231;a tarefa AHA/ACC<sup>9</sup>) e com todos os tipos de restenose de <italic>stent</italic> n&#227;o-farmacol&#243;gico ou farmacol&#243;gico.</p>
    <p>
      <bold>Crit&#233;rios de exclus&#227;o</bold>
    </p>
    <p>Foram exclu&#237;dos deste estudo os indiv&#237;duos submetidos &#224; interven&#231;&#227;o cir&#250;rgica ou percut&#226;nea de outros vasos, al&#233;m do sistema da art&#233;ria descendente anterior, nos tr&#234;s meses precedentes. Exclu&#237;ram-se tamb&#233;m os pacientes com implante de <italic>stent</italic> no tronco da coron&#225;ria esquerda ou da art&#233;ria circunflexa, motivado por les&#227;o ostial da art&#233;ria descendente. Exclu&#237;ram ainda as gestantes ou pacientes com doen&#231;a grave concomitante, com alta probabilidade de &#243;bito no decorrer de 1 ano. E por final os pacientes com impossibilidade econ&#244;mica ou cl&#237;nica de receber a associa&#231;&#227;o dos antiagregantes plaquet&#225;rios clopidogrel e &#225;cido acetilsalic&#237;lico por no m&#237;nimo tr&#234;s meses.</p>
    <p>
      <bold>An&#225;lise estat&#237;stica</bold>
    </p>
    <p>Neste estudo, a vari&#225;vel resposta considerada foi pelo menos um evento (presente ou n&#227;o). Para avalia&#231;&#227;o da associa&#231;&#227;o entre vari&#225;veis dicot&#244;micas e a vari&#225;vel resposta, considerou-se o teste exato de Fisher. Vari&#225;veis cont&#237;nuas foram avaliadas pelo teste <italic>t</italic> de <italic>Student</italic> para amostras independentes, levando-se em conta a homogeneidade ou n&#227;o das vari&#226;ncias, ou pelo teste n&#227;o-param&#233;trico de Mann-Whitney. An&#225;lise multivariada foi realizada ajustando-se um modelo de regress&#227;o log&#237;stica no qual foram inclu&#237;das todas as vari&#225;veis que tivessem valor de p &lt; 0,25<sup>10</sup>. Al&#233;m dessas vari&#225;veis, foram inclu&#237;das outras com relev&#226;ncia cl&#237;nica (sexo, les&#227;o longa &gt;20 mm, tabagismo e di&#226;metro do <italic>stent</italic> implantado).</p>
    <p>Foram inclu&#237;das no modelo de forma dicotomizada as vari&#225;veis cont&#237;nuas - idade, di&#226;metro do bal&#227;o usado para expandir os <italic>stents</italic> p&#243;s-implante e &#225;rea luminal m&#237;nima intra-<italic>stent</italic> -, para as quais foi encontrado um ponto de corte aceit&#225;vel de acordo com o ajuste da curva ROC (&#225;rea abaixo da curva significativamente maior que 0,5 mm).</p>
    <p>Foram considerados aceit&#225;veis os seguintes pontos de corte:</p>
    <list list-type="bullet">
      <list-item>
        <p> idade: 57 anos;</p>
      </list-item>
      <list-item>
        <p>&#225;rea luminal m&#237;nima intra-</p>
        <p><italic>stent</italic>: 3,88 mm</p>
        <p><sup>2</sup>;</p>
      </list-item>
      <list-item>
        <p>di&#226;metro do bal&#227;o usado para expandir os </p>
        <p><italic>stents</italic> p&#243;s-implante: 3 mm.</p>
      </list-item>
    </list>
    <p>A an&#225;lise foi realizada com o <italic>software</italic> SPSS 11.0. Valores de p &lt; 0,05 indicavam signific&#226;ncia estat&#237;stica.</p>
    <p>
      <bold>Casu&#237;stica</bold>
    </p>
    <p>Constitu&#237;ram a casu&#237;stica desta pesquisa os pacientes com doen&#231;a coronariana ateroscler&#243;tica obstrutiva da art&#233;ria descendente anterior, diagnosticada mediante coronariografia invasiva. As les&#245;es obstrutivas apresentavam comprometimento esten&#243;tico da luz arterial maior que 70%, da&#237; a indica&#231;&#227;o do implante de <italic>stent</italic> farmacol&#243;gico como tratamento intervencionista, baseada nos achados cl&#237;nicos e angiogr&#225;ficos. Os pacientes foram tratados com implante de <italic>stent</italic> farmacol&#243;gico com o f&#225;rmaco sirolimus (<italic>stent</italic> Cypher<sup>&#174;</sup>) ou com o f&#225;rmaco paclitaxel (<italic>stent</italic> Taxus<sup>&#174;</sup>). Todas as pr&#243;teses foram selecionadas pelas medidas obtidas na avalia&#231;&#227;o do ultra-som intravascular na fase pr&#233;-implante e otimizadas na sua expans&#227;o com p&#243;s-dilata&#231;&#227;o guiada por ultra-som. A inclus&#227;o dos pacientes iniciou-se em maio de 2002 e terminou em agosto de 2005. Os procedimentos foram realizados no Hospital Cardiol&#243;gico Costantini.</p>
    <p>
      <bold>Resultados</bold>
    </p>
    <p>
      <bold>Caracter&#237;sticas cl&#237;nicas</bold>
    </p>
    <p>Foram tratados com implante de <italic>stent</italic> farmacol&#243;gico 205 pacientes. As caracter&#237;sticas cl&#237;nicas est&#227;o na <xref ref-type="table" rid="tab1">tabela 1</xref>.</p>
    <table-wrap id="tab1">
      <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt01.jpg"/></table-wrap>
    <p>
      <bold>Caracter&#237;sticas angiogr&#225;ficas</bold>
    </p>
    <p>Em 153 indiv&#237;duos (74,63%), a doen&#231;a ateroscler&#243;tica estava restrita &#224; art&#233;ria descendente anterior (pacientes uniarteriais), enquanto em 52 (25,36%) a doen&#231;a comprometia outros vasos, al&#233;m da art&#233;ria descendente anterior (pacientes multiarteriais). As les&#245;es da art&#233;ria descendente anterior envolviam em 56,61% a origem de ramos diagonais maiores de 2,25 mm, les&#227;o em bifurca&#231;&#227;o.</p>
    <p>Nos 205 pacientes, foram tratadas 242 les&#245;es da art&#233;ria descendente anterior (m&#233;dia de 1,18 les&#227;o por paciente), assim classificadas de acordo com a For&#231;a-tarefa AHA/ACC<sup>9</sup>:</p>
    <list list-type="bullet">
      <list-item>
        <p> tipo A: 6 les&#245;es (2,47%);</p>
      </list-item>
      <list-item>
        <p>tipo B1: 23 les&#245;es (9,50%);</p>
      </list-item>
      <list-item>
        <p>tipo B2: 96 les&#245;es (39,66%);</p>
      </list-item>
      <list-item>
        <p>tipo C: 80 les&#245;es (33,57%).</p>
      </list-item>
    </list>
    <p>N&#227;o seguiam a classifica&#231;&#227;o da For&#231;a-tarefa AHA/ACC, por serem resten&#243;ticas, 37 les&#245;es.</p>
    <p>As caracter&#237;sticas isoladas das les&#245;es est&#227;o apresentadas na <xref ref-type="table" rid="tab2">tabela 2</xref>.</p>
    <table-wrap id="tab2">
      <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt02.jpg"/></table-wrap>
    <p>Na art&#233;ria descendente anterior, foram implantados 240 <italic>stents</italic>, dos quais 236 eram farmacol&#243;gicos (1,15 <italic>stent</italic> farmacol&#243;gico por art&#233;ria).</p>
    <p>As diferen&#231;as nas caracter&#237;sticas dos <italic>stents</italic> Cypher<sup>&#174;</sup> e Taxus<sup>&#174;</sup> implantados est&#227;o detalhadas na <xref ref-type="table" rid="tab3">tabela 3</xref>.</p>
    <table-wrap id="tab3">
      <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt03.jpg"/></table-wrap>
    <p>A extens&#227;o m&#233;dia do <italic>stent</italic> farmacol&#243;gico por vaso foi de 27,74&#177;11,59 mm. Na amostra estudada, observou-se, de acordo com a soma das extens&#245;es dos <italic>stents</italic> farmacol&#243;gicos implantados em uma mesma art&#233;ria Descendente Anterior (DA), a seguinte casu&#237;stica:</p>
    <list list-type="bullet">
      <list-item>
        <p>67 DA (32,6%) receberam entre 8 e 20 mm;</p>
      </list-item>
      <list-item>
        <p>55 DA (26,8%) receberam entre 21 e 30 mm;</p>
      </list-item>
      <list-item>
        <p>57 DA (27,8%) receberam entre 31 e 40 mm;</p>
      </list-item>
      <list-item>
        <p>10 DA (4,8%) receberam entre 41 e 50 mm;</p>
      </list-item>
      <list-item>
        <p>16 DA (7,8%) receberam entre 51 e 65 mm.</p>
      </list-item>
    </list>
    <p>
      <bold>Medidas obtidas pela an&#225;lise do ultra-som intravascular</bold>
    </p>
    <p>No segmento de refer&#234;ncia proximal, a &#225;rea do vaso era de 15,13 &#177; 4,36 mm<sup>2</sup>, a &#225;rea do l&#250;men era de 7,62 &#177; 2,55 mm<sup>2</sup>, a porcentagem de estenose de 48,68 &#177; 11,47% e o di&#226;metro de refer&#234;ncia de 3,10 &#177; 0,51mm. No segmento de refer&#234;ncia distal, a &#225;rea do vaso era de 9,94 &#177; 3,51 mm<sup>2</sup>, a &#225;rea do l&#250;mem era de 6,27 &#177; 1,98 mm<sup>2</sup>, a porcentagem de estenose de 35,39 &#177; 13,31% e o di&#226;metro de refer&#234;ncia de 2,82 &#177; 0,43 mm.</p>
    <p>
      <bold>Medidas do ultra-som intravascular do segmento do <italic>stent</italic></bold>
    </p>
    <list list-type="bullet">
      <list-item>
        <p>&#193;rea luminal m&#237;nima (mm</p>
        <p><sup>2</sup>): 5,13 &#177; 1,53.</p>
      </list-item>
      <list-item>
        <p>Di&#226;metro luminal m&#237;nimo (mm): 2,55 &#177; 0,37.</p>
      </list-item>
      <list-item>
        <p>Assimetria: 0,86 &#177; 0,86.</p>
      </list-item>
      <list-item>
        <p>Volume: 190,79 &#177; 93,14.</p>
      </list-item>
    </list>
    <p>
      <bold>Evolu&#231;&#227;o cl&#237;nica</bold>
    </p>
    <p>O acompanhamento dos 205 pacientes teve o per&#237;odo m&#233;dio de 711&#177;306 dias (23,3&#177;10 meses), mais de 8 meses de evolu&#231;&#227;o do &#250;ltimo paciente desta casu&#237;stica. As taxas de ocorr&#234;ncia de trombose de <italic>stent</italic>, infarto agudo do mioc&#225;rdio ou cirurgia de revasculariza&#231;&#227;o miocardica ou TVR foram semelhantes 1/205 - 0,48% para cada desfecho. O &#250;nico paciente com trombose era do sexo masculino, de 43 anos, que havia sido submetido a implante de 1 <italic>stent</italic> Taxus<sup>&#174;</sup> 3,0/16 mm (les&#227;o resten&#243;tica de <italic>stent</italic>). A reinterven&#231;&#227;o com angioplastia convencional ocorreu quatro meses ap&#243;s o implante do <italic>stent</italic> farmacol&#243;gico e 15 dias ap&#243;s a suspens&#227;o do clopidogrel.</p>
    <p>A taxa de 1,46% de &#243;bito corresponde a tr&#234;s pacientes do sexo feminino:</p>
    <list list-type="bullet">
      <list-item>
        <p><italic>Paciente A -</italic> 76 anos de idade, com les&#227;o resten&#243;tica de </p>
        <p><italic>stent</italic> n&#227;o-farmacol&#243;gico, submetida a implante de um </p>
        <p><italic>stent</italic> Cypher</p>
        <p><sup>&#174;</sup> 3,0/18 mm. O procedimento foi realizado em maio de 2002 e o &#243;bito ocorreu em junho de 2005. &#211;bito s&#250;bito, domiciliar.</p>
      </list-item>
      <list-item>
        <p><italic>Paciente B</italic> - 60 anos de idade, diab&#233;tica, com les&#227;o resten&#243;tica de </p>
        <p><italic>stent</italic> n&#227;o-farmacol&#243;gico. Submetida a implante de dois </p>
        <p><italic>stents</italic> Cypher</p>
        <p><sup>&#174;</sup> 2,5/28 mm e 2,5/18 mm. O procedimento foi realizado em dezembro de 2002 e o &#243;bito ocorreu em outubro de 2005. &#211;bito por infarto agudo, na cidade de origem.</p>
      </list-item>
      <list-item>
        <p><italic>Paciente C -</italic> 78 anos de idade, com les&#227;o do tipo B2, submetida a implante de um </p>
        <p><italic>stent</italic> Taxus</p>
        <p><sup>&#174;</sup> 2,75/32 mm. O procedimento foi realizado em fevereiro de 2004 e o &#243;bito ocorreu em agosto de 2005. &#211;bito s&#250;bito, domiciliar, por prov&#225;vel acidente isqu&#234;mico cerebral.</p>
      </list-item>
    </list>
    <p>A taxa de revasculariza&#231;&#227;o da les&#227;o tratada foi de 7,31% (15 pacientes), desses pacientes 9 receberam um novo <italic>stent</italic> farmacol&#243;gico e os demais foram tratados com angioplastia com cateter bal&#227;o com l&#226;minas de tit&#226;nio.</p>
    <p>
      <bold>An&#225;lise univariada</bold>
    </p>
    <p>Neste estudo, a vari&#225;vel resposta considerada foi pelo menos um evento card&#237;aco (presente ou n&#227;o) (<xref ref-type="table" rid="tab4">tab. 4</xref>).</p>
    <table-wrap id="tab4">
      <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt04.jpg"/></table-wrap>
    <p>
      <bold>An&#225;lise multivariada</bold>
    </p>
    <p>Na <xref ref-type="table" rid="tab5">tabela 5</xref>, s&#227;o apresentados os valores de p resultantes do ajuste do modelo de regress&#227;o log&#237;stica, no qual foram inclu&#237;das as vari&#225;veis consideradas no estudo.</p>
    <table-wrap id="tab5">
      <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt05.jpg"/></table-wrap>
    <p>
      <bold>Discuss&#227;o</bold>
    </p>
    <p>Este estudo visou ao acompanhamento cl&#237;nico, em longo prazo (23,3&#177;10 meses de m&#233;dia), de pacientes submetidos &#224; angioplastia da art&#233;ria descendente anterior com implante de um ou mais <italic>stents</italic> farmacol&#243;gicos guiados por ultra-som intravascular. A associa&#231;&#227;o da t&#233;cnica do ultra-som intravascular como guia do implante do <italic>stent</italic> n&#227;o-farmacol&#243;gico permite a otimiza&#231;&#227;o da expans&#227;o deste, diminuindo a restenose tardia<sup>8</sup>. J&#225; no implante dos <italic>stents</italic> farmacol&#243;gicos, o uso do ultra-som intravascular para sele&#231;&#227;o e otimiza&#231;&#227;o da expans&#227;o dos <italic>stents</italic> necessita de valida&#231;&#227;o por estudos cient&#237;ficos. Estudos randomizados com implante de <italic>stents</italic> farmacol&#243;gicos apresentam resultados tardios distintos, os quais est&#227;o diretamente relacionados &#224;s caracter&#237;sticas das les&#245;es tratadas. O estudo Sirius<sup>3</sup> permitiu a inclus&#227;o de les&#245;es longas e vasos finos, elevando o &#237;ndice de restenose tardia para 8,9%, localizada principalmente nos bordos dos <italic>stents</italic>, visto que a restenose intra-<italic>stent</italic> era pequena (3,2%).</p>
    <p>Os dados apresentados imp&#245;em algumas quest&#245;es:</p>
    <list list-type="bullet">
      <list-item>
        <p>Se a sele&#231;&#227;o da extens&#227;o dos </p>
        <p><italic>stents</italic> fosse guiada por ultra-som, priorizando o recobrimento de toda a extens&#227;o da placa culpada, seriam os mesmos os &#237;ndices de restenose de bordos?</p>
      </list-item>
      <list-item>
        <p>Apesar de reconhecidos os baixos &#237;ndices de restenose intra-</p>
        <p><italic>stent</italic> dos </p>
        <p><italic>stents</italic> farmacol&#243;gicos, a otimiza&#231;&#227;o da expans&#227;o dos </p>
        <p><italic>stents</italic> teria impacto tardio positivo?</p>
      </list-item>
    </list>
    <p>Essas s&#227;o perguntas dif&#237;ceis de responder porque implicam muitos vieses da t&#233;cnica do implante dos <italic>stents</italic>, bem como da interpreta&#231;&#227;o pessoal das imagens do ultra-som intravascular.</p>
    <p>O ultra-som intravascular foi usado na avalia&#231;&#227;o pr&#233;-implante do <italic>stent</italic> para an&#225;lise da extens&#227;o da placa ateroscler&#243;tica obstrutiva, o que permitiria que o <italic>stent</italic> escolhido recobrisse todo o segmento da placa, ficando os seus bordos em um segmento com menor carga de placa ou sem les&#227;o ateroscler&#243;tica.</p>
    <p>Todos os <italic>stents</italic> implantados na art&#233;ria descendente anterior tiveram sua expans&#227;o otimizada conforme a avalia&#231;&#227;o do ultra-som intravascular. Independentemente de uma &#243;tima imagem angiogr&#225;fica, se pelo ultra-som se observasse que as pr&#243;teses estavam mal expandidas, os <italic>stents</italic> eram dilatados novamente.</p>
    <p>Com a evolu&#231;&#227;o dos <italic>stents</italic> farmacol&#243;gicas - que tornou poss&#237;vel um bom controle da prolifera&#231;&#227;o neo-intimal -, verificou-se que a perda tardia do di&#226;metro luminal intra-<italic>stent</italic> n&#227;o era baixa somente nos <italic>stents</italic> curtos (menores de 20 mm), mas era muito baixa tamb&#233;m nos <italic>stents</italic> longos<sup>11</sup>. Por essa a&#231;&#227;o dos <italic>stents</italic> farmacol&#243;gicos longos observada nos estudos cient&#237;ficos e na pr&#225;tica cl&#237;nica, passou-se a valorizar ainda mais a import&#226;ncia do reconhecimento da placa ateroscler&#243;tica pelo ultra-som na sele&#231;&#227;o do comprimento dos <italic>stents</italic>, de modo que se pudesse recobrir todo o segmento lesado.</p>
    <p>Neste estudo, a taxa global de (pelo menos um) eventos card&#237;acos foi de 10,24%. Eventos como &#243;bito, cirurgia de revasculariza&#231;&#227;o e infarto agudo do mioc&#225;rdio foram poucos, e entre eles a revasculariza&#231;&#227;o da les&#227;o tratada teve a taxa mais elevada (7,31%), correspondente a 9/ pacientes que receberam um novo <italic>stent</italic> farmacol&#243;gico e a outros 6 submetidos &#224; dilata&#231;&#227;o com cateter bal&#227;o com l&#226;minas de tit&#226;nio.</p>
    <p>A taxa de trombose tardia foi de 0,48% por paciente ou de 0,33% por <italic>stent</italic>, mesmo incluindo pacientes com les&#245;es complexas, <italic>stents</italic> longos, <italic>stents</italic> m&#250;ltiplos e les&#245;es em bifurca&#231;&#245;es, &#237;ndice muito baixo, semelhante ao encontrado em estudos com <italic>stent</italic> n&#227;o-farmacol&#243;gico<sup>12</sup>. Trombose ocorreu em um &#250;nico paciente, que suspendeu o uso do clopidogrel no quarto m&#234;s, evoluindo com trombose intra-<italic>stent</italic> 15 dias ap&#243;s.</p>
    <p>Nesta s&#233;rie, foram tratados todos os tipos de les&#245;es ateroscler&#243;ticas ou de s&#237;ndromes cl&#237;nicas que envolviam a art&#233;ria descendente anterior, e os resultados mostram que &#233; alta (98,54%) a taxa de sobrevida desses pacientes. A restenose cl&#237;nica (taxa de revasculariza&#231;&#227;o da les&#227;o tratada) foi o principal evento tardio observado em nossos pacientes (7,31%). Entretanto, a taxa de revasculariza&#231;&#227;o da les&#227;o tratada foi aqui inferior &#224;s taxas descritas em muitos estudos cl&#237;nicos.</p>
    <p>Os principais fatores indicadores de eventos tardios foram a &#225;rea luminal final avaliada pelo ultra-som e o n&#250;mero de <italic>stents</italic> implantados na art&#233;ria descendente anterior. O di&#226;metro de refer&#234;ncia do vaso, a les&#227;o em bifurca&#231;&#227;o, os <italic>stents</italic> implantados em vasos finos (<underline>&lt;</underline>2,75) ou o tipo de <italic>stent</italic> implantado (Cypher<sup>&#174;</sup> ou Taxus<sup>&#174;</sup>) n&#227;o apresentaram diferen&#231;a estat&#237;stica na an&#225;lise uni ou multivariada.</p>
    <p>Na an&#225;lise univariada realizada na presente pesquisa, observou-se que a &#225;rea luminal intra-<italic>stent</italic> menor que 3,88 mm<sup>2</sup> foi preditiva de eventos, com significativo valor de p (p = 0,0107). Os pacientes com &#225;rea luminal intra-<italic>stent</italic> menor que 3,88 mm<sup>2</sup> na avalia&#231;&#227;o final ao ultra-som apresentaram maior &#237;ndice de eventos quando comparados aos pacientes com &#225;reas luminais intra-<italic>stent</italic> maiores que 3,88 mm<sup>2</sup> (21,28% <italic>vs</italic> 6,96%, respectivamente, com p = 0,01). O tratamento de les&#245;es longas implica a coloca&#231;&#227;o dos <italic>stents</italic> nos segmentos mais distais do vaso, conseq&#252;entemente obtendo uma &#225;rea luminal bem inferior que as &#225;reas obtidas no segmento mais proximal. No momento em que esses <italic>stents</italic> foram bem implantados, verificou-se se todas as hastes dos <italic>stents</italic> estavam bem apostas &#224; parede do vaso, e se a &#225;rea luminal final correspondia &#224;s &#225;reas luminais de refer&#234;ncia. Observamos que os <italic>stents</italic> com &#225;rea luminal final &gt; 3,88 mm<sup>2</sup> pelo ultra-som apresentaram melhor evolu&#231;&#227;o tardia (esta &#225;rea luminal corresponde &#224; &#225;rea luminal m&#237;nima desejada nos segmentos considerados vasos finos). Entretanto, o encontro de uma &#225;rea luminal final de 3,88 mm<sup>2</sup> em um segmento de vaso calibroso implica uma pr&#243;tese hipoexpandida, com hastes soltas no interior da luz do vaso, podendo interferir no resultado tardio. Esta hip&#243;tese n&#227;o foi analisada nesta casu&#237;stica, visto que todos os <italic>stents</italic> foram hiperexpandidos, com &#225;reas adequadas &#224; &#225;rea luminal de refer&#234;ncia proximal e distal.</p>
    <p>Trinta e um pacientes receberam mais de um <italic>stent</italic> farmacol&#243;gico implantado na art&#233;ria descendente anterior; destes, 7 (22,58%) apresentaram pelo menos um evento. O implante de <italic>stents</italic> longos (m&#233;dia da extens&#227;o dos <italic>stents</italic> implantados nesta casu&#237;stica foi de 24,11) n&#227;o foi um fator de aumento de riscos tardios, por&#233;m o implante de duas pr&#243;teses foi um fator independente de eventos. Esse achado fortalece a import&#226;ncia da disponibilidade de <italic>stents</italic> longos com apresenta&#231;&#227;o maiores de 30 mm de extens&#227;o, o que orienta o intervencionista a utilizar esses <italic>stents</italic> em vez de implantar duas pr&#243;teses para o tratamento de les&#245;es longas.</p>
    <p>Um fato muito curioso verificou-se aqui: a &#250;nica caracter&#237;stica angiogr&#225;fica com p menor que 0,25 mm foi a excentricidade das les&#245;es (p = 0,18). As les&#245;es conc&#234;ntricas foram preditivas independentes de eventos, do mesmo modo que as les&#245;es exc&#234;ntricas apresentaram <italic>odd ratio</italic> de 0,24 (95% IC 0,07-0,81).</p>
    <p>Nesta casu&#237;stica, as les&#245;es exc&#234;ntricas foram um indicativo protetor contra eventos (p = 0,012, <italic>odd ratio</italic> 0,24 (95% IC 0,07-0,81)). O fato provavelmente relacionado &#224; distribui&#231;&#227;o das hastes do <italic>stent</italic>, que geralmente se separam junto da parede com menor resist&#234;ncia, ou seja, com menor quantidade de placa, e se agrupam no lado de menor expans&#227;o, &#233; o segmento com mais placa.</p>
    <p>A an&#225;lise multivariada demonstrou tend&#234;ncia estat&#237;stica do diabetes como indicador independente de eventos card&#237;acos; os n&#227;o-diab&#233;ticos apresentaram um <italic>odd ratio</italic> de 0,31 (95% IC 0,10-1,02) (p = 0,0536), portanto o diabete n&#227;o foi um forte preditor de eventos como demonstrado na literatura. Este fato pode estar relacionado &#224; caracter&#237;stica do grupo de pacientes n&#227;o-diab&#233;ticos que tamb&#233;m receberam <italic>stents</italic> longos, equiparando a extens&#227;o de malha met&#225;lica por vaso entre os grupos. Com o advento dos <italic>stents</italic> farmacol&#243;gicos, observa-se que os efeitos protetores dos f&#225;rmacos tamb&#233;m se estendem aos pacientes diab&#233;ticos, que apresentam evolu&#231;&#227;o muito semelhante &#224; dos pacientes n&#227;o-diab&#233;ticos. No entanto, ainda n&#227;o se pode afirmar que seja poss&#237;vel controlar por completo eventos tardios dos pacientes diab&#233;ticos.</p>
    <p>Muitos estudos cl&#237;nicos demonstraram a boa evolu&#231;&#227;o obtida com <italic>stents</italic> farmacol&#243;gicos em vasos menores que 2,75 mm (vasos finos). Nesta s&#233;rie, a taxa de eventos foi de 13,12% com o uso de <italic>stents</italic> menores que 3 mm, e de 9,03% (p = 0,45) com <italic>stents</italic> maiores. Essa vari&#225;vel foi estudada na regress&#227;o log&#237;stica por sua relev&#226;ncia como indicativo nos estudos com <italic>stents</italic> met&#225;licos. Na an&#225;lise multivariada, encontrou-se um p n&#227;o-significativo (p = 0,14).</p>
    <p>A casu&#237;stica estudada representa a experi&#234;ncia de um &#250;nico grupo, que tem como caracter&#237;stica o uso rotineiro do ultra-som intracoronariano para guiar o implante dos <italic>stents</italic> farmacol&#243;gicos. Este estudo marca principalmente quais s&#227;o os pacientes livres de eventos (porcentagem de acerto de 99,5% pelo modelo ajustado da regress&#227;o log&#237;stica).</p>
    <p>
      <bold>Conclus&#227;o</bold>
    </p>
    <p>Baseados nos dados obtidos, conclu&#237;mos que a revasculariza&#231;&#227;o da art&#233;ria descendente anterior com implante de <italic>stents</italic> farmacol&#243;gicos escolhidos e otimizados pelo ultra-som intravascular apresenta baixo &#237;ndice de eventos tardios. O implante de dois <italic>stents</italic> farmacol&#243;gicos para o tratamento das les&#245;es longas foi o principal fator independente para a ocorr&#234;ncia de eventos tardios. A &#225;rea luminal final maior que 3,88 mm<sup>2</sup> obtidos nos segmentos de pequenos di&#226;metros de referencia &#233; um indicador independente de evolu&#231;&#227;o livre de eventos.</p>
    <p>
      <bold>Potencial Conflito de Interesses</bold>
    </p>
    <p>Declaro n&#227;o haver conflito de interesses pertinentes.</p>
    <p>
      <bold>Fontes de Financiamento</bold>
    </p>
    <p>O presente estudo n&#227;o teve fontes de financiamento externas.</p>
    <p>
      <bold>Vincula&#231;&#227;o Acad&#234;mica</bold>
    </p>
    <p>Este artigo &#233; parte de tese de Doutorado de Marcelo de Freitas Santos pela Faculdade de Ci&#234;ncias M&#233;dicas da Santa Casa de S&#227;o Paulo.</p>
    <p>
      <fn id="back" fn-type="corresp">
        <p>Correspond&#234;ncia:</p>
        <p> Marcelo de Freitas Santos  </p>
        <p> Rua Monsenhor Ivo Zanlorenzi, 2546/1901 </p>
        <p> Mossungue, 81210-000, Curitiba, PR - Brasil </p>
        <p> E-mail: </p>
        <p>
          <email xlink:href="mfsantos@cardiol.br">mfsantos@cardiol.br</email>
        </p>
      </fn>
    </p>
    <p>Artigo recebido em 12/03/07; revisado recebido em 04/11/07; aceito em 14/04/08.</p>
  </body>
  <back>
    <ref-list>
      <ref id="B1">
        <mixed-citation>1. Morice MC, Serruys    PW, Sousa JE, Fajadet J, Hayashi EB, Perin M, et al. [for The Ravel Study    Group]. A randomized comparison of a sirolimus: eluting stent with a standard    stent for coronary revascularization. N Engl J Med. 2002; 346 (23): 1773-80.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>A randomized comparison of a sirolimus: eluting stent with a standard stent for coronary revascularization</article-title>
          <source>N Engl J Med</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>1773</fpage>
          <lpage>80</lpage>
          <issue>23</issue>
          <volume>346</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Morice</surname>
              <given-names>MC</given-names>
            </name>
            <name>
              <surname>Serruys</surname>
              <given-names>PW</given-names>
            </name>
            <name>
              <surname>Sousa</surname>
              <given-names>JE</given-names>
            </name>
            <name>
              <surname>Fajadet</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Hayashi</surname>
              <given-names>EB</given-names>
            </name>
            <name>
              <surname>Perin</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Fajadet J, Morice    MC, Bode C, Barragan P, Serruys PW, Wijns W, et al. Maintenance of long-term    clinical benefit with sirolimus-eluting coronary stents: three-year results    of the Ravel trial. Circulation. 2005; 111 (8): 1040-4.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Maintenance of long-term clinical benefit with sirolimus-eluting coronary stents: three-year results of the Ravel trial</article-title>
          <source>Circulation</source>
          <date>
            <year>2005</year>
          </date>
          <fpage>1040</fpage>
          <lpage>4</lpage>
          <issue>8</issue>
          <volume>111</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Fajadet</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Morice</surname>
              <given-names>MC</given-names>
            </name>
            <name>
              <surname>Bode</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Barragan</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Serruys</surname>
              <given-names>PW</given-names>
            </name>
            <name>
              <surname>Wijns</surname>
              <given-names>W</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. Moses JW, Leon    MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, et al. [for the    Sirius Investigators]. Sirolimus: eluting stents versus standard stents    in patients with stenosis in a native coronary artery. N Engl J Med. 2003; 349    (14): 1315-23.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Sirolimus: eluting stents versus standard stents in patients with stenosis in a native coronary artery</article-title>
          <source>N Engl J Med</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>1315</fpage>
          <lpage>23</lpage>
          <issue>14</issue>
          <volume>349</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Moses</surname>
              <given-names>JW</given-names>
            </name>
            <name>
              <surname>Leon</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Popma</surname>
              <given-names>JJ</given-names>
            </name>
            <name>
              <surname>Fitzgerald</surname>
              <given-names>PJ</given-names>
            </name>
            <name>
              <surname>Holmes</surname>
              <given-names>DR</given-names>
            </name>
            <name>
              <surname>O'Shaughnessy</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Holmes DR Jr,    Leon MB, Moses JW, Popma JJ, Cutlip D, Fitzgerald PJ, et al. Analysis of 1-year    clinical outcomes in the Sirius trial: a randomized trial of a sirolimus-eluting    stent versus a standard stent in patients at high risk for coronary restenosis.    Circulation. 2004; 109 (5): 634-40.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Analysis of 1-year clinical outcomes in the Sirius trial: a randomized trial of a sirolimus-eluting stent versus a standard stent in patients at high risk for coronary restenosis</article-title>
          <source>Circulation</source>
          <date>
            <year>2004</year>
          </date>
          <fpage>634</fpage>
          <lpage>40</lpage>
          <issue>5</issue>
          <volume>109</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Holmes Jr</surname>
              <given-names>DR</given-names>
            </name>
            <name>
              <surname>Leon</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Moses</surname>
              <given-names>JW</given-names>
            </name>
            <name>
              <surname>Popma</surname>
              <given-names>JJ</given-names>
            </name>
            <name>
              <surname>Cutlip</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Fitzgerald</surname>
              <given-names>PJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. Schofer J, Schl&#252;ter    M, Gershlick AH, Wijns W, Garcia E, Schampaert E, et al. [for the E-Sirius    Investigators]. Sirolimus-eluting stents for treatment of patients with    long atherosclerotic lesions in small coronary arteries: double-blind, randomised    controlled trial (E-Sirius). Lancet. 2003; 362 (9390): 1093-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-Sirius)</article-title>
          <source>Lancet</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>1093</fpage>
          <lpage>9</lpage>
          <issue>9390</issue>
          <volume>362</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Schofer</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Schl&#252;ter</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Gershlick</surname>
              <given-names>AH</given-names>
            </name>
            <name>
              <surname>Wijns</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Garcia</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Schampaert</surname>
              <given-names>E</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B6">
        <mixed-citation>6. Schl&#252;ter    M, Schofer J, Gershlick AH, Schampaert E, Wijns W, Breithardt G, et al. [for    the E- and C-SIRIUS Investigators]. Direct stenting of native de novo coronary    artery lesions with the sirolimus: eluting stent a post hoc subanalysis of the    pooled E- and C- Sirius trials. J Am Coll Cardiol. 2005; 45 (1): 10-3.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Direct stenting of native de novo coronary artery lesions with the sirolimus: eluting stent a post hoc subanalysis of the pooled E- and C- Sirius trials</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2005</year>
          </date>
          <fpage>10</fpage>
          <lpage>3</lpage>
          <issue>1</issue>
          <volume>45</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Schl&#252;ter</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Schofer</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Gershlick</surname>
              <given-names>AH</given-names>
            </name>
            <name>
              <surname>Schampaert</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Wijns</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Breithardt</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B7">
        <mixed-citation>7. Colombo A, Moses    JW, Morice MC, Ludwig J, Holmes DR Jr, Spanos V, et al. Randomized study to    evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions.    Circulation. 2004; 109 (10): 1244-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions</article-title>
          <source>Circulation</source>
          <date>
            <year>2004</year>
          </date>
          <fpage>1244</fpage>
          <lpage>9</lpage>
          <issue>10</issue>
          <volume>109</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Colombo</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Moses</surname>
              <given-names>JW</given-names>
            </name>
            <name>
              <surname>Morice</surname>
              <given-names>MC</given-names>
            </name>
            <name>
              <surname>Ludwig</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Holmes Jr</surname>
              <given-names>DR</given-names>
            </name>
            <name>
              <surname>Spanos</surname>
              <given-names>V</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B8">
        <mixed-citation>8. Casella G, Klauss    V, Ottani F, Siebert U, Sangiorgio P, Bracchetti D. Impact of intravascular    ultrasound-guided stenting on long-term clinical outcome: a meta-analysis of    available studies comparing intravascular ultrasound-guided and angiographically    guided stenting. Cathet Cardiovasc Intervent. 2003; 59 (3): 314-21.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Impact of intravascular ultrasound-guided stenting on long-term clinical outcome: a meta-analysis of available studies comparing intravascular ultrasound-guided and angiographically guided stenting</article-title>
          <source>Cathet Cardiovasc Intervent</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>314</fpage>
          <lpage>21</lpage>
          <issue>3</issue>
          <volume>59</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Casella</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Klauss</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Ottani</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Siebert</surname>
              <given-names>U</given-names>
            </name>
            <name>
              <surname>Sangiorgio</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Bracchetti</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B9">
        <mixed-citation>9. Ryan TJ, Faxon    DP, Gunnar RM, Kennedy JW, King SB 3rd, Loop FD, et al. Guidelines for percutaneous    transluminal coronary angioplasty: a report of the American College of Cardiology/American    Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular    Procedures (Subcommittee on Percutaneous Transluminal Coronary Angioplasty).    Circulation. 1988; 78 (2): 486-502.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Guidelines for percutaneous transluminal coronary angioplasty: a report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Subcommittee on Percutaneous Transluminal Coronary Angioplasty)</article-title>
          <source>Circulation</source>
          <date>
            <year>1988</year>
          </date>
          <fpage>486</fpage>
          <lpage>502</lpage>
          <issue>2</issue>
          <volume>78</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Ryan</surname>
              <given-names>TJ</given-names>
            </name>
            <name>
              <surname>Faxon</surname>
              <given-names>DP</given-names>
            </name>
            <name>
              <surname>Gunnar</surname>
              <given-names>RM</given-names>
            </name>
            <name>
              <surname>Kennedy</surname>
              <given-names>JW</given-names>
            </name>
            <name>
              <surname>King 3rd</surname>
              <given-names>SB</given-names>
            </name>
            <name>
              <surname>Loop</surname>
              <given-names>FD</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B10">
        <mixed-citation>10. Hosmer DW,    Lemeshow S. Applied logistic regression. New York: Wiley; 1989.</mixed-citation>
        <element-citation publication-type="book">
          <source>Applied logistic regression</source>
          <date>
            <year>1989</year>
          </date>
          <person-group person-group-type="author">
            <name>
              <surname>Hosmer</surname>
              <given-names>DW</given-names>
            </name>
            <name>
              <surname>Lemeshow</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B11">
        <mixed-citation>11. Cardiovascular    Research Foundation. Drug-eluting stent: clinical trials. CD9. In: 2004 TCT    Meeting (Transcatheter Cardiovascular Tehrapeutics). Washington; 2004.</mixed-citation>
        <element-citation publication-type="confproc">
          <date>
            <year>2004</year>
          </date>
        </element-citation>
      </ref>
      <ref id="B12">
        <mixed-citation>12. Colombo A,    Hall P, Nakamura S, Almagor Y, Maiello L, Martini G, et al. Intracoronary stenting    without anticoagulation accomplished with intravascular ultrasound guidance.    Circulation. 1995; 91 (6): 1676-88.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance</article-title>
          <source>Circulation</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>1676</fpage>
          <lpage>88</lpage>
          <issue>6</issue>
          <volume>91</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Colombo</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Hall</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Nakamura</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Almagor</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Maiello</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Martini</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Articles</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Pharmacological stent deployment in the left anterior descending artery: late event indicators</article-title>
      </title-group>
      <abstract xml:lang="en">
        <p>BACKGROUND: The efficacy of pharmacological stents in decreasing the incidence of cardiac events is not homogeneous for all lesions or patient subgroups. OBJECTIVE: 1) To evaluate the late clinical evolution of patients submitted to pharmacological stent implantation in atherosclerotic lesions of the left anterior descending artery; 2) to identify, among the clinical, angiographic and intravascular ultrasonographic characteristics, the ones predictive of cardiac event risk. METHODS: From May 2002 to August 2005, 205 patients were treated with 236 pharmacological stent implants, guided by the intravascular US (IVUS). RESULTS: After a mean follow-up period of 711 days, the rate of stent thrombosis was 0.48%, the same observed for acute myocardial infarction or revascularization surgery. The revascularization rate of the treated lesion was 7.31% and the general event rate was 10.24%. The event indicators, according to the multivariate analysis were the implant of more than one stent in the same artery, concentric lesions and the minimal intra-stent area measured by IVUS &lt; 3.88 mm&#178;. CONCLUSION: Based on the data obtained, we conclude that the revascularization of the left anterior descending artery with pharmacological stent implant, chosen and optimized by IVUS, presents a low incidence of late events. The implant of two pharmacological stents for the treatment of long lesions was the main independent factor for the occurrence of late events. The final luminal area &gt; 3.88 mm&#178; obtained in the small reference-diameter segments is an independent indicator of event-free evolution.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>Angioplasty, balloon</kwd>
        <kwd>stents</kwd>
        <kwd>ultrasonics</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>ORIGINAL ARTICLE</bold>
      </p>
      <p>
        <fn id="top-body2">
          <label>
            <bold>Pharmacological stent deployment in the left anterior descending artery: late event indicators </bold>
          </label>
          <p>
            <bold>Marcelo de Freitas Santos<sup>I</sup>; Sergio Gustavo Tarbine<sup>I</sup>; Costantino Ortiz Costantini<sup>I</sup>; Maria do Rocio Peixoto Oliveira<sup>I</sup>; Marcos Henrique Bubna<sup>I</sup>; Luiz Cesar Guarita-Souza<sup>I</sup>; Chiu Yun Yu Braga<sup>I</sup>; Francisco de Paula Stella<sup>II</sup>; Costantino Roberto Costantini<sup>I</sup>; Luiz Antonio Rivetti<sup>II</sup></bold>
          </p>
        </fn>
      </p>
      <p><sup>I</sup>Hospital Cardiol&#243;gico Costantini</p>
      <p><sup>II</sup>Faculdade de Ci&#234;ncias M&#233;dicas da Santa Casa de S&#227;o Paulo, S&#227;o Paulo, SP - Brasil</p>
      <p>Mailing address</p>
      <p>
        <bold>SUMMARY</bold>
      </p>
      <p><bold>BACKGROUND:</bold> The efficacy of pharmacological stents in decreasing the incidence of cardiac events is not homogeneous for all lesions or patient subgroups.</p>
      <p><bold>OBJECTIVE:</bold> 1) To evaluate the late clinical evolution of patients submitted to pharmacological stent implantation in atherosclerotic lesions of the left anterior descending artery; 2) to identify, among the clinical, angiographic and intravascular ultrasonographic characteristics, the ones predictive of cardiac event risk.</p>
      <p><bold>METHODS:</bold> From May 2002 to August 2005, 205 patients were treated with 236 pharmacological stent implants, guided by the intravascular US (IVUS).</p>
      <p><bold>RESULTS:</bold> After a mean follow-up period of 711 days, the rate of stent thrombosis was 0.48%, the same observed for acute myocardial infarction or revascularization surgery. The revascularization rate of the treated lesion was 7.31% and the general event rate was 10.24%. The event indicators, according to the multivariate analysis were the implant of more than one stent in the same artery, concentric lesions and the minimal intra-stent area measured by IVUS &lt; 3.88 mm<sup>2</sup>.</p>
      <p><bold>CONCLUSION:</bold> Based on the data obtained, we conclude that the revascularization of the left anterior descending artery with pharmacological stent implant, chosen and optimized by IVUS, presents a low incidence of late events. The implant of two pharmacological stents for the treatment of long lesions was the main independent factor for the occurrence of late events. The final luminal area &gt; 3.88 mm<sup>2</sup> obtained in the small reference-diameter segments is an independent indicator of event-free evolution.</p>
      <p><bold>Key words:</bold> Angioplasty, balloon; stents; ultrasonics.</p>
      <p>
        <bold>Introduction</bold>
      </p>
      <p>The pharmacological stents with antiproliferative agents have as target the suppression of neointimal hyperplasia. The pharmacological actions of these agents directly block the cell cycle in its initial phase (cytostatic phase) or in its final phase (cytotoxic phase). The sirolimus-coated (rapamycin) or paclitaxel-coated pharmacological stents - the most extensively studied pharmacological prosthesis with long-term evolution - have presented a significant decrease in late events, especially due to the decrease in the re-stenosis, when compared to non-pharmacological (metallic) stents<sup>1-4</sup>.</p>
      <p>The good evolution of the anterior descending artery revascularization is an independent indicator of survival in the main comparative surgical studies of patients receiving or not mammary artery grafts.</p>
      <p>This revascularization technique is extensively indicated, mainly in patients with complex lesions in the anterior descending artery - lesions that involve the diagonal branches, long lesions (&gt; 20 mm), thin vessels (&lt; 2.75 mm of diameter) or due to association with diabetes mellitus.</p>
      <p>These subgroups were included in many studies that were randomized for the use of pharmacological stents<sup>3,5-7</sup>; however, they were not specific for the anterior descending artery (ADA). The acknowledged benefit of the pharmacological stents in selected groups, in the several aforementioned randomized studies, allows a good evolution of the ADA revascularization, regardless of the complexity of the atherosclerotic lesion or its present clinical characteristic.</p>
      <p>Some studies have suggested that the use of IVUS to guide non-pharmacological stent implants could reduce the incidence of late re-stenosis in some subgroups of patients<sup>8</sup>. Regarding the participation of this resource to guide pharmacological stents, however, the published studies have been scarce.</p>
      <p>The aims of the present study are:</p>
      <p>1) To evaluate the late clinical evolution (cardiac events) of patients submitted to the treatment of atherosclerotic lesions of the ADA with pharmacological stent implants;</p>
      <p>2) To identify, among the clinical, angiographic and intravascular ultrasonographic characteristics, the ones that allow us to predict the risk of cardiac events.</p>
      <p>
        <bold>Methods</bold>
      </p>
      <p>
        <bold>Pre-procedure assessment</bold>
      </p>
      <p>All patients submitted to the intervention procedure had presented a previous diagnostic coronary angiography. On the day before the procedure, following the standard operations of the Service, they were submitted to clinical evaluation, electrocardiographic and laboratory assessment - complete blood count, creatinine and fasting glycemia. The prescribed medication was aspirin 200 mg, clopidogrel 300 mg and the attending physician's statin of choice. The patients' other usual medications were maintained, except anticoagulants and oral hypoglycemic drugs. A six-hour fasting, prior to entering the hemodynamic room, was prescribed.</p>
      <p>Before the release of the pharmacological stents, the pre-dilation of the lesions was carried out using the conventional balloons with a diameter between 2.0 mm and 3.5 mm or through atheroabrasive techniques. A direct implant without pre-dilation was performed when conditions favorable for its expansion were seen to be present.</p>
      <p>The pharmacological stents were released with a pressure between 4 and 18 ATM and the complementary dilation was carried out with a balloon that was shorter than the stent length, which allows the expansion of the latter without injuring its borders. After the adequate angiographic result of stent release (residual lesion &lt; 10% by the subject analysis of the operator) and based on the measurements obtained post-implant with IVUS, the necessity of new dilations was assessed.</p>
      <p>
        <bold>Intravascular ultrasound</bold>
      </p>
      <p>A transducer catheter Atlantis of 40 MHz was used, which has a rotating angulated mirror in its extremity that rotates at 1,800 rpm in the front of the sound-wave emitting crystal. The emitted sound waves were received and transformed into images of the interior of the vessel by the Galaxy or Clearview ultrasound device, by Boston Scientific, which projected them on the screen in real-time and stored them in video cassette tapes. The pre-implant analysis of the pharmacological stent aimed at evaluating the proximal and distal reference diameters, as well as the extension of the atherosclerotic plaque in order to select the ideal pharmacological stent (in diameter as well as in extension). In the post-implant control, a good apposition of the stent rods to the vessel walls and a correlation between intra-stent minimal luminal areas and the reference areas were sought.</p>
      <p>The calculations of the assessment of the post-implant IVUS were carried out with the Echoplaque 2 program, version 2.5.x, by Indec Systems Inc, California, USA.</p>
      <p>
        <bold>Clinical follow-up</bold>
      </p>
      <p>The patients were followed by their clinicians throughout the entire process. In May and June 2006, the occurrence of major cardiac events was verified by telephone contact.</p>
      <p>The late events that were emphasized were:</p>
      <p>- death;</p>
      <p>- acute myocardial infarction;</p>
      <p>- thrombosis of the pharmacological stent, defined as acute or late angiographic occlusion of the stents;</p>
      <p>- target lesion revascularization (TLR), characterized as any new surgical or percutaneous revascularization caused by an angiographic re-stenosis of previously dilated lesions;</p>
      <p>- target vessel revascularization (TVR), characterized by any new surgical or percutaneous revascularization caused by a re-stenosis or a new lesion in the previously dilated vessel.</p>
      <p>
        <bold>Inclusion criteria</bold>
      </p>
      <p>Patients aged 18 years or older, regardless of gender, risk factors and clinical syndrome at the moment of admission; with indication of interventionist treatment only for the ADA, associated or not to the septal or diagonal branches. Left ventricular ejection fraction (EF) was &gt; 30% in all patients and the reference diameter of the ADA was e" 2.25 mm. The uniarterial and multiarterial patients were joined, with all types of <italic>de-novo</italic> atherosclerotic lesions (nomenclature by the AHA/ACC task force<sup>9</sup>) and all types of non-pharmacological or pharmacological stent re-stenosis.</p>
      <p>
        <bold>Exclusion criteria</bold>
      </p>
      <p>To have been submitted to surgical or percutaneous intervention of other vessels other than the ADA system during the prior three months; patients with stent implant in the left coronary trunk or circumflex artery, caused by ostial lesion of the descending artery; pregnant patients those with concomitant severe disease, with high probability of death within 12 months and patients with economic or clinic limitations to receive the association of the platelet antiaggregants clopidogrel and acetylsalicylic acid for at least three months.</p>
      <p>
        <bold>Statistical analysis</bold>
      </p>
      <p>In the present study, the considered response variable was at least one event (present or not). To evaluate the association between dichotomous variables and the response variable, Fisher exact test was considered. Continuous variables were assessed by the Student's <italic>t</italic> test for independent samples, considering the homogeneity or not of the variances, or by the non-parametric Mann-Whitney test. A multivariate analysis was carried out by adjusting a model of logistic regression that included all variables that had a p value &lt; 0.25<sup>10</sup>. In addition to these variables, others were included, which had clinical relevance (gender, long lesion &gt; 20 mm, smoking and implanted stent diameter).</p>
      <p>The continuous variables age, diameter of the balloon used to expand the post-implant stents and minimal intra-stent luminal area were included in the model in the dichotomized form; an acceptable cutoff was found according to the adjustment of the ROC curve (area below the curve significantly &gt; 0.5 mm).</p>
      <p>The following cutoffs were considered acceptable:</p>
      <p>- age: 57 years;</p>
      <p>- minimal intra-stent luminal area: 3.88 mm<sup>2</sup>;</p>
      <p>- diameter of the balloon used to expand the post-implant stents: 3 mm.</p>
      <p>The statistical analysis was carried out using the software SPSS 11.0. Statistical significance was set at p&lt;0.05.</p>
      <p>
        <bold>Patients</bold>
      </p>
      <p>This sample consisted of patients with obstructive atherosclerotic coronary disease of the anterior descending artery (ADA), diagnosed by invasive coronary angiography.</p>
      <p>The obstructive lesions presented stenotic involvement of the arterial lumen &gt; 70%, thus the indication of the pharmacological stent implant as the interventionist treatment, based on the clinical and angiographic findings.</p>
      <p>The patients were treated with sirolimus-eluting (Cypher&#153; stent) or paclitaxel-eluting stent implant (Taxus&#153; stent). All the prostheses were selected through the measurements obtained at the ultrasonographic assessment in the pre-implant phase and optimized in their expansion with post-dilation guided by US. Patient inclusion started in May 2002 and finished in August 2005. The procedures were carried out in <italic>Hospital Cardiol&#243;gico Costantini</italic>.</p>
      <p>
        <bold>Results</bold>
      </p>
      <p>
        <bold>Clinical characteristics</bold>
      </p>
      <p>A total of 205 patients were treated with pharmacological stent implant, whose clinical characteristics are shown in <xref ref-type="table" rid="tab1-body2">Table 1</xref>.</p>
      <table-wrap id="tab1-body2">
        <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt01-en.jpg"/></table-wrap>
      <p>
        <bold>Angiographic characteristics</bold>
      </p>
      <p>In 153 individuals (74.63%) the atherosclerotic disease was restricted to the anterior descending artery (ADA), whereas in 52 (23.36%), the disease involved other vessels rather than the ADA (multiarterial patients). The lesions in the ADA involved, in 56.61% of the cases, the origin of the diagonal branches larger than 2.25 mm, bifurcation lesion.</p>
      <p>A total of 242 lesions of the ADA were treated in the 205 patients (mean of 1.18 lesions per patient), thus classified according to the AHA/ACC task force<sup>9</sup>:</p>
      <p>- type A: 6 lesions (2.47%);</p>
      <p>- type B1: 23 lesions (9.50%);</p>
      <p>- type B2: 96 lesions (39.66%);</p>
      <p>- type C: 80 lesions (33.57%).</p>
      <p>Thirty-seven lesions did not follow the classification by the AHA/ACC task force, as they were re-stenotic lesions. The isolated characteristics of the lesions are shown in <xref ref-type="table" rid="tab2-body2">Table 2</xref>. A total of 240 stents were implanted in the ADA, of which 236 were pharmacological ones (1.51 pharmacological stents per artery).</p>
      <table-wrap id="tab2-body2">
        <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt02-en.jpg"/></table-wrap>
      <p>The characteristic differences between the implanted Cypher&#153; and Taxus&#153; stents are shown in <xref ref-type="table" rid="tab3-body2">Table 3</xref>.</p>
      <table-wrap id="tab3-body2">
        <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt03-en.jpg"/></table-wrap>
      <p>The mean extension of the pharmacological stents per vessel was 27.74&#177;11.59/ mm. In the studied sample, according to the addition of the extensions of the pharmacological stents implanted in a same anterior descending artery (ADA), the following data was observed:</p>
      <p>- 67 ADAs (32.6%) received between 8 and 20 mm;</p>
      <p>- 55 ADAs (26.8%) received between 21 and 30 mm;</p>
      <p>- 57 ADAs (27.8%) received between 31 and 40 mm;</p>
      <p>- 10 ADAs (4.8%) received between 41 and 50 mm;</p>
      <p>- 16 ADAs (7.8%) received between 51 and 65 mm.</p>
      <p>These measurements were obtained through the analysis of the intravascular US</p>
      <p>In the proximal reference segment, the vessel area was 15.13 &#177; 4.36 mm<sup>2</sup>, the lumen area was 7.62 &#177; 2.55mm<sup>2</sup>, the percentage of stenosis was 48.68 &#177; 11.47% and the reference diameter was 3.10 &#177; 0.51mm. In the distal reference segment, the vessel area was 9.94 &#177; 3.51 mm<sup>2</sup>, the lumen area was 6.27 &#177; 1.98mm<sup>2</sup>, the percentage of stenosis was 35.39 &#177; 13.31% and the reference diameter was 2.82 &#177; 0.43mm.</p>
      <p>The measurements of the intravascular US of the stent segment were:</p>
      <p>- Minimal luminal area (mm<sup>2</sup>) of 5.13&#177;1.53;</p>
      <p>- Minimal luminal diameter (mm) 2.55&#177;0.37;</p>
      <p>- Asymmetry 0.86&#177;0.86;</p>
      <p>- Volume 190;79&#177;93;14.</p>
      <p>
        <bold>Clinical evolution</bold>
      </p>
      <p>The mean follow-up period of the 205 patients was 711&#177;306 days (23.3&#177;10 months), more than 8 months of evolution of the last patient in this series. The incidence rates of stent thrombosis, acute myocardial infarction or revascularization surgery or TVR were similar: 1/205 - 0.48% for each outcome. The only patient with thrombosis was a 43 year-old male that had been submitted to one Taxus&#153; implant 3.0/16 mm (re-stenotic stent lesion). The reintervention with conventional angioplasty occurred 4 months after the pharmacological stent implant and 15 days after clopidogrel withdrawal.</p>
      <p>The 1.46% death rate corresponds to three female patients:</p>
      <p><italic>- Patient A -</italic> 76 years old, with re-stenotic lesion of non-pharmacological stent, submitted to the implant of 1 Cypher&#153; stent, 3.0/18 mm. The procedure was carried out in May 2002 and the death occurred in June 2005. Sudden death occurred at home.</p>
      <p><italic>- Patient B -</italic> 60 years old, diabetic, with re-stenotic lesion of non-pharmacological stent. Submitted to the implant of 2 Cypher&#153; stents, 2.5/28 mm and 2.5/18 mm. The procedure was carried out in December 2002 and the death occurred in October 2005. Death by acute infarction occurred in her hometown.</p>
      <p><italic>- Patient C -</italic> 78 years old, lesion type B2, submitted to the implant of one Taxus&#153; stent 2.75/32 mm. The procedure was carried out in February 2004 and the death occurred in August 2005. Sudden death occurred at home, probably due to cerebral ischemic accident.</p>
      <p>The incidence of TVR was 7.31% (15 patients), of which 9 received a new pharmacological stent and the others were treated with angioplasty with balloon-catheter with titanium blades.</p>
      <p>
        <bold>Univariate analysis</bold>
      </p>
      <p>In the present study, the considered response variable was at least 1 cardiac event (present or not, <xref ref-type="table" rid="tab4-body2">Table 4</xref>).</p>
      <table-wrap id="tab4-body2">
        <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt04-en.jpg"/></table-wrap>
      <p>
        <bold>Multivariate analysis</bold>
      </p>
      <p><xref ref-type="table" rid="tab5-body2">Table 5</xref> shows the p values resulting from the adjustment of the logistic regression model, which included the variables considered in the study.</p>
      <table-wrap id="tab5-body2">
        <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt05-en.jpg"/></table-wrap>
      <p>
        <bold>Discussion</bold>
      </p>
      <p>This study aimed the long-term follow-up (mean of 23.3&#177;10 months) of patients submitted to the angioplasty of the anterior descending artery (ADA) with the implant of one or more pharmacological stents guided by intravascular ultrasound (IVUS). The association of the IVUS technique as a guide to implant the non-pharmacological stent allows its optimization, decreasing the late re-stenosis<sup>8</sup>. As for the implant of pharmacological stents, the use of IVUS to select and optimize the stent expansion needs to be validated by scientific studies.</p>
      <p>Randomized studies with the implant of pharmacological stents present distinct late outcomes, which are directly related to the characteristics of the treated lesions. The Sirius<sup>3</sup> study allowed the inclusion of long lesions and thin vessels, raising the incidence of late stenosis to 8.9%, located mainly in the stent borders, considering that the incidence of intra-stent re-stenosis was low (3.2%).</p>
      <p>The data presented raise some questions: If the selection of the extension of stents were guided by ultrasound, prioritizing the lining of the entire extension of the target plaque, would the rates of stent border re-stenosis be the same? Although the rates of intra-stent re-stenosis of pharmacological stents are known to be low, would the optimization of the stent expansion have a positive late effect?</p>
      <p>These are difficult questions to answer, as they involve many biases of the stent implant technique, as well as of the personal interpretation of the IVUS images.</p>
      <p>The intravascular ultrasound was used in the pre-implant assessment of the stent to analyze the extension of the obstructive atherosclerotic plaque, which would allow the chosen stent to recover the entire segment of the plaque, with its borders in a segment with a lower plaque load or without atherosclerotic lesion.</p>
      <p>All stents implanted in anterior descending artery had their expansion optimized according to the IVUS assessment. Regardless of an optimal angiographic image, if the ultrasound assessment showed that the prostheses were not adequately expanded, the stents were dilated again.</p>
      <p>With the development of the pharmacological stents - which allowed a good control of the neointimal proliferation - it was observed that the later loss of the intra-stent luminal diameter was low not only in the short stents (shorter than 20 mm), but was very low in long stents, as well<sup>11</sup>. Due to this action of long pharmacological stents observed in scientific studies and in clinical practice, the importance of the assessment of the atherosclerotic plaque by ultrasound in the selection of the length of the stents, so that the entire injured segment could be covered, increased even more.</p>
      <p>In this study, the general rate of (at least one) cardiac events was 10.24%. Events such as death, revascularization surgery and acute myocardial infarction were scarce and among them, the rates of TVR were the highest (7.31%), corresponding to 9 patients that received a new pharmacological stent and other 6 patients submitted to dilation with catheter-balloon with titanium blades.</p>
      <p>The incidence of late thrombosis was 0.48% per patient or 0.33% per stent, even when including patients with complex lesions, long stents, multiple stents and bifurcation lesions; this is a very low incidence, similar to the one found in studies with non-pharmacological stents<sup>12</sup>.</p>
      <p>Thrombosis occurred in only one patient that withdrew the use of clopidogrel in the fourth month, developing an intra-stent thrombosis 15 days later.</p>
      <p>In this series, all types of atherosclerotic lesions or clinical syndromes that involved the ADA were treated, and the results show that the survival rate among these patients is high (98.54%). The clinical re-stenosis (target vessel revascularization rate) was the main late event observed in our series (7.31%). However, the TVR rate observed here was lower than the ones described in many clinical studies.</p>
      <p>The main factors that indicated late events were the final luminal area evaluated by ultrasound and the number of stents implanted in the ADA. The reference diameter of the vessel, bifurcation lesion, stents implanted in thin vessels (d" 2.75) or the type of stent implanted (Cypher&#153; or Taxus&#153;) did not show any statistical difference at the uni- or multivariate analysis.</p>
      <p>The univariate analysis carried out in the present study showed that the intra-stent luminal area &lt; 3.88 mm<sup>2</sup> was an event predictor, with a significant p value (p=0.0107). The patients with an intra-stent luminal area &lt; 3.88 mm<sup>2</sup> at the final ultrasound assessment presented a higher incidence of events when compared to patients with intra-stent luminal area &gt; 3.88 mm<sup>2</sup> (21.28 % <italic>vs</italic> 6.96%, respectively, with p= 0.01). The treatment of long lesions implies in the implant of stents in the most distal segments of the vessel, consequently obtaining a luminal area that is quite smaller than the areas obtained in the most proximal segment. When these stents are well-implanted, it is verified if there is a good apposition of all the stent rods to the vessel wall and if the final luminal area corresponds to the reference luminal area. We observed that the stents with final luminal area &gt; 3.88 mm<sup>2</sup> at the ultrasound presented a better late evolution (this luminal area corresponds to the minimal wanted luminal area in the segments considered to be thin vessels). However, the finding of a final luminal area of 3.88 mm<sup>2</sup> in a segment of a large-caliber vessel implicates in a hypo-expanded prosthesis, with loose rods inside the lumen of the vessel, which can interfere in the late outcome. This hypothesis was not analyzed in this series, as all the stents were hyper-expanded, with areas that were adequate to the proximal an distal reference luminal areas.</p>
      <p>Thirty-one patients had more than 1 pharmacological stent implanted in the ADA; of these, 7 (22.58%) presented at least one event. The implant of long stents (mean length of stents implanted in this series: 24.11) was not a late event risk increase factor; however, the implant of two prostheses was an independent event factor. This finding supports the importance of the availability of long stents, with more 30 mm of length, indicating to the interventionist the use of these stents, instead of the implant of two prostheses for the treatment of long lesions.</p>
      <p>A noteworthy fact observed herein was that the only angiographic characteristic with a p value &lt; 0.25 was lesion eccentricity (p=0.18). The concentric lesions were independent predictors of events, similarly to the eccentric lesions that had an OR = 0.24 (95%CI: 0.07-0.81). The fact might be related to the distribution of the stent rods, which usually separate close to the wall with less resistance, i.e., with less plaque, and gather on the side with lower expansion, which is the segment with more plaque.</p>
      <p>The multivariate analysis showed a statistical tendency of diabetes to be an independent indicator of cardiac events; non-diabetic individuals presented an odds ratio of 0.31 (95%CI: 0.10-1.02; p=0.0536), thus diabetes was not a strong predictor of events as shown in the literature; this fact might be related to the characteristic of the group of non-diabetic patients that also received long stents, equaling the extension of the metallic net per vessel between the groups. The advent of pharmacological stents showed that the protective effects of the drugs also extend to the diabetic patients, who present evolution that is very similar to that of non-diabetic patients. However, one cannot affirm that it is possible to fully control late events in diabetic patients.</p>
      <p>Many clinical studies have demonstrated the good evolution with pharmacological stents in vessels &lt; 2.75 mm (thin vessels). In this series, the rate of events was 13.12% with the use of stents &lt; 3mm and 9.03% (p=0.45) with longer stents. This variable was studied in the logistic regression due to its relevance as an indicative factor in studies with metallic stents. The multivariate analysis showed a non-significant p (p=0.14).</p>
      <p>The studied series represents the experience of a single group that has as its characteristic, the routine use of intracoronary ultrasound to guide the implant of pharmacological stents. This study shows mainly which patients are event-free (percentage of exactness of 99.5% by the adjusted model of logistic regression).</p>
      <p>
        <bold>Conclusion</bold>
      </p>
      <p>Based on the obtained data, we conclude that the revascularization of the anterior descending artery with the implant of pharmacological stents chosen and optimized by the use of intravascular ultrasound presents a low incidence of late events. The implant of pharmacological stents for the treatment of long lesions was the main independent factor for the occurrence of late events. The final luminal area &gt; 3.88 mm<sup>2</sup>, obtained in segments of small reference diameters is an independent indicator of event-free evolution.</p>
      <p>
        <bold>Potential Conflict of Interest</bold>
      </p>
      <p>No potential conflict of interest relevant to this article was reported.</p>
      <p>
        <bold>Sources of Funding</bold>
      </p>
      <p>There were no external funding sources for this study.</p>
      <p>
        <bold>Study Association</bold>
      </p>
      <p>This article is part of the thesis of doctoral submitted by Marcelo de Freitas Santos, from <italic>Faculdade de Ci&#234;ncias M&#233;dicas da Santa Casa de S&#227;o Paulo</italic>.</p>
      <p>
        <bold>References</bold>
      </p>
    </body>
  </sub-article>
  <sub-article article-type="translation" id="TRes" xml:lang="es">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Art&#237;culos Originales</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="es">Implante de Stents farmacol&#243;gicos en la arteria descendente anterior: indicadores de eventos tard&#237;os</article-title>
      </title-group>
      <abstract xml:lang="es">
        <p>FUNDAMENTO: La eficacia de los stents farmacol&#243;gicos para reducir los &#237;ndices de eventos cardiacos no es la misma para todos los subgrupos de lesiones o pacientes. OBJETIVO: Evaluar la evoluci&#243;n cl&#237;nica tard&#237;a de los pacientes sometidos a implante de stents farmacol&#243;gicos en las lesiones ateroscler&#243;ticas de la arteria descendente anterior e identificar, entre las caracter&#237;sticas cl&#237;nicas, angiogr&#225;ficas y de ultrasonido intravascular, cuales son las que permiten predecir riesgos de eventos cardiacos M&#201;TODOS: De mayo de 2002 a agosto de 2005, se trataron a 205 pacientes con implante de 236 stents farmacol&#243;gicos guiados por ultrasonido intravascular. RESULTADOS: Con un seguimiento promedio de 711 d&#237;as, la tasa de trombosis del stent fue del 0,48%, la misma que se observ&#243; para infarto agudo de miocardio o cirug&#237;a de revascularizaci&#243;n. La tasa de revascularizaci&#243;n de la lesi&#243;n tratada fue del 7,31% y la tasa global de eventos fue del 10,24%. Los indicadores de eventos, conforme an&#225;lisis multivariada, fueron el implante de m&#225;s de un stent en la misma arteria, lesiones conc&#233;ntricas y &#225;rea m&#237;nima intrastent medida por el ultrasonido intravascular menor que 3,88 mm&#178;. CONCLUSI&#211;N: Tomando como base los datos obtenidos con esta investigaci&#243;n, concluimos que la revascularizaci&#243;n de la arteria descendente anterior con implante de stents farmacol&#243;gicos, elegidos y optimizados por el ultrasonido intravascular, presenta un bajo &#237;ndice de eventos tard&#237;os. El implante de dos stents farmacol&#243;gicos para el tratamiento de las lesiones largas fue el principal factor independiente para la ocurrencia de eventos tard&#237;os. El &#225;rea luminal final mayor que 3,88 mm&#178;, obtenida en los segmentos de peque&#241;os di&#225;metros de referencia es un indicador independiente de evoluci&#243;n libre de eventos.</p>
      </abstract>
      <kwd-group xml:lang="es">
        <kwd>Angioplastia transluminal</kwd>
        <kwd>contenedores</kwd>
        <kwd>ultrasonido</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>ART&#205;CULO ORIGINAL</bold>
      </p>
      <p>
        <fn id="top-body3">
          <label>
            <bold>Implante de <italic>Stents</italic> farmacol&#243;gicos en la arteria descendente anterior. Indicadores de eventos tard&#237;os</bold>
          </label>
          <p>
            <bold>Marcelo de Freitas Santos<sup>I</sup>; Sergio Gustavo Tarbine<sup>I</sup>; Costantino Ortiz Costantini<sup>I</sup>; Maria do Rocio Peixoto Oliveira<sup>I</sup>; Marcos Henrrique Bubna<sup>I</sup>; Luiz Cesar Guarita-Souza<sup>I</sup>; Chiu Yun Yu Braga<sup>I</sup>; Francisco de Paula Stella<sup>II</sup>; Costantino Roberto Costantini<sup>I</sup>; Luiz Antonio Rivetti<sup>II</sup></bold>
          </p>
        </fn>
      </p>
      <p><sup>I</sup>Hospital Cardiol&#243;gico Costantini, S&#227;o Paulo, SP - Brazil</p>
      <p><sup>II</sup>Faculdade de Ci&#234;ncias M&#233;dicas da Santa Casa de S&#227;o Paulo, S&#227;o Paulo, SP - Brazil</p>
      <p>Correspondencia</p>
      <p>
        <bold>RESUMEN</bold>
      </p>
      <p><bold>FUNDAMENTO: </bold> La eficacia de los <italic>stents</italic> farmacol&#243;gicos para reducir los &#237;ndices de eventos cardiacos no es la misma para todos los subgrupos de lesiones o pacientes.</p>
      <p><bold>OBJETIVO: </bold> Evaluar la evoluci&#243;n cl&#237;nica tard&#237;a de los pacientes sometidos a implante de <italic>stents</italic> farmacol&#243;gicos en las lesiones ateroscler&#243;ticas de la arteria descendente anterior e identificar, entre las caracter&#237;sticas cl&#237;nicas, angiogr&#225;ficas y de ultrasonido intravascular, cuales son las que permiten predecir riesgos de eventos cardiacos</p>
      <p><bold>M&#201;TODOS: </bold> De mayo de 2002 a agosto de 2005, se trataron a 205 pacientes con implante de 236 stents farmacol&#243;gicos guiados por ultrasonido intravascular.</p>
      <p><bold>RESULTADOS:</bold> Con un seguimiento promedio de 711 d&#237;as, la tasa de trombosis del stent fue del 0,48%, la misma que se observ&#243; para infarto agudo de miocardio o cirug&#237;a de revascularizaci&#243;n. La tasa de revascularizaci&#243;n de la lesi&#243;n tratada fue del 7,31% y la tasa global de eventos fue del 10,24%. Los indicadores de eventos, conforme an&#225;lisis multivariada, fueron el implante de m&#225;s de un stent en la misma arteria, lesiones conc&#233;ntricas y &#225;rea m&#237;nima intrastent medida por el ultrasonido intravascular menor que 3,88 mm<sup>2</sup>.</p>
      <p><bold>CONCLUSI&#211;N: </bold> Tomando como base los datos obtenidos con esta investigaci&#243;n, concluimos que la revascularizaci&#243;n de la arteria descendente anterior con implante de <italic>stents</italic> farmacol&#243;gicos, elegidos y optimizados por el ultrasonido intravascular, presenta un bajo &#237;ndice de eventos tard&#237;os. El implante de dos stents farmacol&#243;gicos para el tratamiento de las lesiones largas fue el principal factor independiente para la ocurrencia de eventos tard&#237;os. El &#225;rea luminal final mayor que 3,88 mm<sup>2</sup>, obtenida en los segmentos de peque&#241;os di&#225;metros de referencia es un indicador independiente de evoluci&#243;n libre de eventos.</p>
      <p><bold>Palabras-clave: </bold> Angioplastia transluminal, contenedores, ultrasonido.</p>
      <p>
        <bold>Introducci&#243;n</bold>
      </p>
      <p>Los <italic>stents</italic> farmacol&#243;gicos con agentes antiproliferativos tienen como blanco la supresi&#243;n de la hiperplasia neointimal. Las acciones farmacol&#243;gicas de esos agentes bloquean directamente el ciclo celular en su fase inicial (acci&#243;n citost&#225;tica) o en su fase final (acci&#243;n citot&#243;xica). Los <italic>stents</italic> farmacol&#243;gicos con sirolimus (rapamicina) o con paclitaxel &#151;las pr&#243;tesis farmacol&#243;gicas m&#225;s extensivamente estudiadas con evoluci&#243;n a largo plazo&#151; han presentado significativa redu-cci&#243;n de los eventos tard&#237;os, principalmente por la reducci&#243;n de la restenosis, si comparados a los <italic>stents</italic> no farmacol&#243;gicos (met&#225;licos)<sup>1-4</sup>.</p>
      <p>La buena evoluci&#243;n de la revascularizaci&#243;n de la arteria descendente anterior es un indicador independiente de sobrevida en los principales estudios quir&#250;rgicos comparativos de pacientes receptores o no de injerto de arteria mamaria. Se indica la realizaci&#243;n de esa t&#233;cnica de revascularizaci&#243;n, de modo extensivo, principalmente en los pacientes con lesiones complejas en la arteria descendente anterior &#151;lesiones que implican las ramas diagonales, lesiones largas (&gt;20/ mm), vasos finos (&lt;2,75/ mm de di&#225;metro) o por asociaci&#243;n a la diabetes mellitus. Muchos estudios randomizados incluyeron esos subgrupos para la utilizaci&#243;n de los <italic>stents</italic> farmacol&#243;gicos<sup>3,5-7</sup>, pero no espec&#237;ficos a la arteria descendente anterior. En los diversos estudios randomizados ya referidos, se reconoci&#243;, en grupos seleccionados, el beneficio aportado por los <italic>stents</italic> farmacol&#243;gicos: permite una buena evoluci&#243;n de la revascularizaci&#243;n de la arteria descendente anterior, independientemente de la complejidad de la lesi&#243;n ateroscler&#243;tica o de la caracter&#237;stica cl&#237;nica presente.</p>
      <p>Algunos estudios sugieren que la utilizaci&#243;n de ultrasonido intravascular (IVUS), como m&#233;todo gu&#237;a del implante de los <italic>stents</italic> no farmacol&#243;gicos, podr&#237;a reducir las tasas de restenosis tard&#237;a en determinados subgrupos de pacientes<sup>8</sup>. En cuanto a la participaci&#243;n de ese recurso como gu&#237;a en el implante de <italic>stents</italic> farmacol&#243;gicos, sin embargo, las investigaciones publicadas hasta ahora son todav&#237;a insuficientes.</p>
      <p>Siguen a continuaci&#243;n los objetivos de esta investigaci&#243;n:</p>
      <list list-type="bullet">
        <list-item>
          <p> Evaluar la evoluci&#243;n cl&#237;nica (eventos cardiacos) tard&#237;a de los pacientes sometidos a tratamiento de lesiones de la arteria descendente anterior con implante de </p>
          <p><italic>stents</italic> farmacol&#243;gicos.</p>
        </list-item>
        <list-item>
          <p>Identificar, entre las caracter&#237;sticas cl&#237;nicas, angiogr&#225;ficas y de ultrasonido intravascular, cuales son las que permiten indicar riesgos de eventos cardiacos.</p>
        </list-item>
      </list>
      <p>
        <bold>M&#233;todos</bold>
      </p>
      <p>
        <bold>Evaluaci&#243;n pre procedimiento</bold>
      </p>
      <p>Todos los pacientes sometidos al procedimiento intervencionista presentaron previamente una cinecoronariograf&#237;a diagn&#243;stica. El d&#237;a anterior al procedimiento, bajo una estandarizaci&#243;n del servicio, se los sometieron a evaluaci&#243;n cl&#237;nica, electrocardio-gr&#225;fica y laboratorial &#151;hemograma, creatinina y glicemia de ayuno. La medicaci&#243;n prescrita fue aspirina (200/ mg), clopidogrel (300/ mg) y una estatina de elecci&#243;n del m&#233;dico asistente. Los pacientes siguieron tomando las otras medicaciones habituales, a excepci&#243;n de los anticoagulantes y hipoglucemiantes orales. Se prescribi&#243; ayuno a los pacientes, seis horas antes de que fueran a la sala de hemodin&#225;mica.</p>
      <p>Antes de la liberaci&#243;n de los <italic>stents</italic> farmacol&#243;gicos, se hizo la predilataci&#243;n de las lesiones mediante la utilizaci&#243;n de los balones convencionales, con di&#225;metro entre 2,0 mm y 3,5 mm, o con t&#233;cnicas atero-ablativas. Se efectu&#243; implante directo, sin predilataci&#243;n, al observarse condiciones favorables para su expansi&#243;n.</p>
      <p>Se liberaron los <italic>stents</italic> farmacol&#243;gicos con presi&#243;n entre 4 y 18 atm, y la dilataci&#243;n complementaria se realiz&#243; con bal&#243;n de extensi&#243;n menor que la del <italic>stent</italic>, lo que permite la expansi&#243;n de &#233;ste sin da&#241;ar a sus bordes. Tras el resultado angiogr&#225;fico adecuado de la liberaci&#243;n del <italic>stent</italic> (lesi&#243;n residual menor que el 10% por el an&#225;lisis subjetivo del operador) y tomando como base las medidas obtenidas post implante con ultrasonido intravascular, se hizo una evaluaci&#243;n de la necesidad de nuevas dilataciones.</p>
      <p>
        <bold>Ultrasonido intravascular</bold>
      </p>
      <p>Se utiliz&#243; el cat&#233;ter transductor Atlantis de 40 MHz, cuya extremidad lleva un espejo angulado rotatorio con velocidad de 1.800 rpm, frente al cristal emisor de las ondas sonoras. El aparato de ultrasonido Galaxy o Clearview (de la empresa Boston Scientific) emit&#237;a las ondas sonoras, que tras recibidas, se transformaban en im&#225;genes del interior del vaso; el aparato dispon&#237;a las im&#225;genes en la pantalla en tiempo real y las almacenaba en cinta de videocasete. El an&#225;lisis pre implante del <italic>stent</italic> farmacol&#243;gico ten&#237;a como objetivo evaluar los di&#225;metros de referencia proximales y distales, as&#237; como la extensi&#243;n de la placa ateroscler&#243;tica, para la selecci&#243;n ideal del <italic>stent</italic> farmacol&#243;gico (tanto en el di&#225;metro como en la extensi&#243;n). En el control post implante, se busc&#243; una buena ubicaci&#243;n de las astas de los <italic>stents</italic> en la pared del vaso y la correlaci&#243;n entre &#225;reas luminales m&#237;nimas intrastent y las &#225;reas de referencia.</p>
      <p>Los c&#225;lculos de la evaluaci&#243;n del IVUS post implante se realizaron con el programa Echoplaque 2, versi&#243;n 2.5.x, de la empresa Indec Systems Inc, California, USA.</p>
      <p>
        <bold>Seguimiento cl&#237;nico</bold>
      </p>
      <p>Los pacientes fueron seguidos por sus m&#233;dicos durante todo el proceso. En los meses de mayo y junio de 2006, se hizo un levantamiento, por medio de llamada telef&#243;nica, de los eventos cardiacos mayores.</p>
      <p>Se puso &#233;nfasis a los eventos tard&#237;os a continuaci&#243;n:</p>
      <list list-type="bullet">
        <list-item>
          <p>&#211;bito;</p>
        </list-item>
        <list-item>
          <p>Infarto agudo de miocardio;</p>
        </list-item>
        <list-item>
          <p>Trombosis del </p>
          <p><italic>stent</italic> farmacol&#243;gico, definida como oclusi&#243;n angiogr&#225;fica aguda o tard&#237;a de los </p>
          <p><italic>stents</italic>;</p>
        </list-item>
        <list-item>
          <p>Tasa de revascularizaci&#243;n de la lesi&#243;n tratada (TLR), caracterizada como cualquier nueva revascularizaci&#243;n quir&#250;rgica o percut&#225;nea, resultante de una restenosis angiogr&#225;fica de las lesiones previamente dilatadas;</p>
        </list-item>
        <list-item>
          <p>Tasa de revascularizaci&#243;n del vaso blanco (TVR), caracterizada como cualquier nueva revascularizaci&#243;n quir&#250;rgica o percut&#225;nea, resultante de una restenosis o de una nueva lesi&#243;n en el vaso previamente tratado.</p>
        </list-item>
      </list>
      <p>
        <bold>Criterios de inclusi&#243;n</bold>
      </p>
      <p>Participaron del estudio pacientes con edad superior a los 18 a&#241;os, independientemente del sexo, de factores de riesgo y del s&#237;ndrome cl&#237;nico al ingreso, con indicaci&#243;n de tratamiento intervencionista solamente de la arteria descendente ante-rior asociada o no a las ramas septales o diagonales. En todos los pacientes, la fracci&#243;n de eyecci&#243;n del ventr&#237;culo izquierdo era mayor que el 30%, y el di&#225;metro de referencia de la arteria descendente anterior mayor o igual a 2,25/ mm. Se implicaron a los pacientes uniarteriales o multiarteriales, con todos los tipos de lesi&#243;n ateroscler&#243;tica "de nuevo" (nomenclatura de la fuerza de tarea AHA/ACC<sup>9</sup>) y con todos los tipos de restenosis de <italic>stent</italic> no farmacol&#243;gico o farmacol&#243;gico.</p>
      <p>
        <bold>Criterios de inclusi&#243;n</bold>
      </p>
      <p>Se excluyeron de este estudio a los individuos sometidos a la intervenci&#243;n quir&#250;rgica o percut&#225;nea de otros vasos, adem&#225;s del sistema de la arteria descendente anterior, en los tres meses precedentes. Se excluyeron tambi&#233;n a los pacientes con implante de <italic>stent</italic> en el tronco de la arteria coronaria izquierda o de la arteria circunfleja, motivado por lesi&#243;n ostial de la arteria descendente. Tambi&#233;n se excluyeron a las mujeres gestantes o a pacientes con enfermedad grave concomitante, con alta probabilidad de &#243;bito al transcurrir 1 a&#241;o. Y, por fin, los pacientes con imposibilidad econ&#243;mica o cl&#237;nica de recibir la asociaci&#243;n de los antiagregantes plaquetarios clopidogrel y &#225;cido acetilsalic&#237;lico por al menos tres meses.</p>
      <p>
        <bold>An&#225;lisis estad&#237;stico</bold>
      </p>
      <p>En este estudio, se consider&#243; al menos un evento (presente o no) como la variable respuesta. Para evaluaci&#243;n de la asociaci&#243;n entre las variables dicot&#243;micas y la variable respuesta, se tom&#243; en cuenta la prueba exacta de Fisher. Variables contin&#250;as fueron evaluadas por la prueba t de Student para muestras independientes &#151;tom&#225;ndose en consideraci&#243;n la homogeneidad o no de las variancias&#151;, o por la prueba no param&#233;trica de Mann-Whitney. Se realiz&#243; el an&#225;lisis multivariado con el ajuste de un modelo de regresi&#243;n log&#237;stica en el cual se incluyeron todas las variables que tuvieran valor de p &lt; 0,25<sup>10</sup>. Adem&#225;s de esas variables, se incluyeron otras con relevancia cl&#237;nica (sexo, lesi&#243;n larga &gt;20 mm, tabaquismo y di&#225;metro del <italic>stent</italic> implantado).</p>
      <p>El modelo incluy&#243;, de forma dicotomizada, las variables contin&#250;as &#151;edad, di&#225;metro del bal&#243;n utilizado para expandir los <italic>stents</italic> post implante y &#225;rea luminal m&#237;nima intrastent<bold><italic>&#151;</italic></bold>, y se encontr&#243; para estas un punto de corte aceptable de acuerdo con el ajuste de la curva ROC (&#225;rea abajo de la curva significativamente mayor que 0,5/ mm).</p>
      <p>Se tomaron en cuenta los puntos de corte que siguen a continuaci&#243;n:</p>
      <disp-quote>
        <p>&#149; Edad: 57 a&#241;os;</p>
        <p>&#149; &#193;rea luminal m&#237;nima intrastent: 3,88/ mm<sup>2</sup>;</p>
        <p>&#149; Di&#225;metro del bal&#243;n utilizado para expandir los <italic>stents</italic> post implante: 3 mm.</p>
      </disp-quote>
      <p>El an&#225;lisis se realiz&#243; con el <italic>software</italic> SPSS 11.0. Valores de p &lt; 0,05 indicaban significancia estad&#237;stica.</p>
      <p>
        <bold>Casu&#237;stica</bold>
      </p>
      <p>Formaron parte de la casu&#237;stica de esta investigaci&#243;n los pacientes con enfermedad coronaria ateroscler&#243;tica obstructiva de la arteria descendente anterior, diagnosticada mediante coronario-graf&#237;a invasiva. Las lesiones obstructivas presentaban compromiso esten&#243;tico de la luz arterial mayor que el 70%. Ello justific&#243; la indicaci&#243;n del implante de <italic>stent</italic> farmacol&#243;gico como tratamiento intervencionista, basada en los hallazgos cl&#237;nicos y angiogr&#225;ficos. A los pacientes se trataron con implante de <italic>stent</italic> farmacol&#243;gico con el f&#225;rmaco sirolimus (<italic>stent</italic> Cypher<sup>&#174;</sup>) o con el f&#225;rmaco paclitaxel (<italic>stent</italic> Taxus<sup>&#174;</sup>). Todas las pr&#243;tesis fueron seleccionadas por las medidas obtenidas en la evaluaci&#243;n del ultrasonido intravascular en la fase pre implante y optimizadas en su expansi&#243;n con post dilataci&#243;n guiada por ultrasonido. La inclusi&#243;n de los pacientes tuvo inicio en mayo de 2002 y se acab&#243; en agosto de 2005. Los procedimientos se analizaron en el Hospital Cardiol&#243;gico Costantini.</p>
      <p>
        <bold>Resultados</bold>
      </p>
      <p>
        <bold>Caracter&#237;sticas cl&#237;nicas</bold>
      </p>
      <p>Se trataron con implante de <italic>stent</italic> farmacol&#243;gico a 205 pacientes. Las caracter&#237;sticas cl&#237;nicas est&#225;n presentadas en la <xref ref-type="table" rid="t1-body3">Tabla 1</xref>.</p>
      <table-wrap id="t1-body3">
        <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt01-es.jpg"/></table-wrap>
      <p>
        <bold>Caracter&#237;sticas angiogr&#225;ficas</bold>
      </p>
      <p>En 153 individuos (74,63%), la enfermedad ateroscler&#243;tica estaba restricta a la arteria descen-dente anterior (pacientes uniarteriales), mientras que en 52 pacientes (25,36%) la enfermedad compromet&#237;a otros vasos, adem&#225;s de la arteria descendente anterior (pacientes multiarteriales). Las lesiones de la arteria descendente anterior implicaban en el 56,61% el origen de ramas diagonales mayores de 2,25 mm, lesi&#243;n en bifurcaci&#243;n.</p>
      <p>En los 205 pacientes, se trataron 242 lesiones de la arteria descendente anterior (promedio de 1,18 lesi&#243;n por paciente), as&#237; clasificadas de acuerdo con la Fuerza de Tarea AHA/ACC<sup>9</sup>:</p>
      <list list-type="bullet">
        <list-item>
          <p>Clase A: 6 lesiones (2,47%);</p>
        </list-item>
        <list-item>
          <p>Clase B1: 23 lesiones (9,50%);</p>
        </list-item>
        <list-item>
          <p>Clase B2: 96 lesiones (39,66%);</p>
        </list-item>
        <list-item>
          <p>Clase C: 80 lesiones (33,57%);</p>
        </list-item>
      </list>
      <p>Un total de 37 lesiones no segu&#237;a la clasificaci&#243;n de la Fuerza de Tarea AHA/ACC, por su condici&#243;n resten&#243;tica.</p>
      <p>Las caracter&#237;sticas aisladas de las lesiones est&#225;n presentadas en la <xref ref-type="table" rid="t2-body3">Tabla 2</xref>.</p>
      <table-wrap id="t2-body3">
        <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt02-es.jpg"/></table-wrap>
      <p>En la arteria descendente anterior, se implantaron 240 <italic>stents</italic>, de los cuales 236 eran farmacol&#243;gicos (1,15 <italic>stent</italic> farmacol&#243;gico por arteria).</p>
      <p>Las diferencias en las caracter&#237;sticas de los <italic>stents</italic> Cypher<sup>&#174;</sup> y Taxus<sup>&#174;</sup> implantados est&#225;n detalladas en la <xref ref-type="table" rid="t3-body3">Tabla 3</xref>.</p>
      <table-wrap id="t3-body3">
        <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt03-es.jpg"/></table-wrap>
      <p>La extensi&#243;n promedio del <italic>stent</italic> farmacol&#243;gico por vaso fue de 27,74<underline>+</underline>11,59/ mm. En la muestra estudiada, se observ&#243;, de acuerdo con el total de las extensiones de los <italic>stents</italic> farmacol&#243;gicos implantados en una misma arteria descendente anterior (DA), la siguiente casu&#237;stica:</p>
      <list list-type="bullet">
        <list-item>
          <p>67 DA (32,6%) recibieron entre 8 y 20/ mm;</p>
        </list-item>
        <list-item>
          <p>55 DA (26,8%) recibieron entre 21 y 30/ mm;</p>
        </list-item>
        <list-item>
          <p>57 DA (27,8%) recibieron entre 31 y 40/ mm;</p>
        </list-item>
        <list-item>
          <p>10 DA (4,8%) recibieron entre 41 y 50/ mm;</p>
        </list-item>
        <list-item>
          <p>16 DA (7,8%) recibieron entre 51 y 65/ mm;</p>
        </list-item>
      </list>
      <p>
        <bold>Medidas obtenidas mediante el an&#225;lisis del ultrasonido intravascular</bold>
      </p>
      <p>En el segmento de referencia proximal, el &#225;rea del vaso era de 15,13 <underline>+</underline> 4,36 mm2, el &#225;rea del l&#250;men era de 7,62 <underline>+</underline> 2,55 mm2, el porcentaje de estenosis de 48,68 <underline>+</underline> 11,47% y el di&#225;metro de referencia de 3,10 <underline>+</underline> 0,51mm. En el segmento de referencia distal, el &#225;rea del vaso era de 9,94 <underline>+</underline> 3,51 mm<sup>2</sup>, el &#225;rea del l&#250;men era de 6,27 <underline>+</underline> 1,98 mm<sup>2</sup>, el porcentaje estenosis de 35,39 <underline>+</underline> 13,31% y el di&#225;metro de referencia de 2,82 <underline>+</underline> 0,43 mm.</p>
      <p>
        <bold>Medidas del ultrasonido intravascular del segmento del <italic>stent</italic></bold>
      </p>
      <list list-type="bullet">
        <list-item>
          <p>&#193;rea luminal m&#237;nima (mm</p>
          <p><sup>2</sup>): 5,13 </p>
          <p><underline>+</underline> 1,53.</p>
        </list-item>
        <list-item>
          <p>Di&#225;metro luminal m&#237;nimo (mm): 2,55 </p>
          <p><underline>+</underline> 0,37.</p>
        </list-item>
        <list-item>
          <p>Asimetr&#237;a: 0,86 </p>
          <p><underline>+</underline> 0,86.</p>
        </list-item>
        <list-item>
          <p>Volumen: 190,79 </p>
          <p><underline>+</underline> 93,14.</p>
        </list-item>
      </list>
      <p>
        <bold>Evoluci&#243;n cl&#237;nica</bold>
      </p>
      <p>El seguimiento de los 205 pacientes tuvo la duraci&#243;n promedio de 711<underline>+</underline>306 d&#237;as (23,3<underline>+</underline>10 meses), m&#225;s de 8 meses de evoluci&#243;n del &#250;ltimo paciente de esta casu&#237;stica. Las tasas de ocurrencia de trombosis de <italic>stent</italic>, infarto agudo de miocardio, cirug&#237;a de revascularizaci&#243;n mioc&#225;rdica o TVR se mostraron semejantes 1/205 &#151;0,48% para cada desenlace. El &#250;nico paciente con trombosis era del sexo masculino, de 43 a&#241;os, que se sometiera a implante de 1 <italic>stent</italic> Taxus<sup>&#174;</sup> 3,0/16/ mm (lesi&#243;n resten&#243;tica de <italic>stent</italic>). La reintervenci&#243;n con angioplastia convencional ocurri&#243; cuatro meses tras el implante del <italic>stent</italic> farmacol&#243;gico y 15 d&#237;as despu&#233;s de la suspensi&#243;n del clopidogrel.</p>
      <p>La tasa del 1,46% de &#243;bito corresponde a tres pacientes del sexo femenino:</p>
      <list list-type="bullet">
        <list-item>
          <p><bold><italic>Paciente A</italic></bold>: 76 a&#241;os de edad, con lesi&#243;n resten&#243;tica de </p>
          <p><italic>stent</italic> no farmacol&#243;gico, sometida a implante de un </p>
          <p><italic>stent</italic> Cypher</p>
          <p><sup>&#174;</sup> 3,0/18/ mm. El procedimiento se reali-z&#243; en mayo de 2002 y el &#243;bito tuvo lugar en junio de 2005. &#211;bito s&#250;bito, domiciliar.</p>
        </list-item>
        <list-item>
          <p><bold><italic>Paciente B</italic></bold>: 60 a&#241;os de edad, diab&#233;tica, con lesi&#243;n resten&#243;tica de </p>
          <p><italic>stent</italic> no farmacol&#243;gico. Sometida a implante de dos </p>
          <p><italic>stents</italic> Cypher</p>
          <p><sup>&#174;</sup> 2,5/28/ mm y 2,5/18/ mm. El procedimiento tuvo lugar en diciembre de 2002 y el &#243;bito ocurri&#243; en octu-bre de 2005. &#211;bito por infarto agudo, en la ciudad de origen.</p>
        </list-item>
        <list-item>
          <p><bold><italic>Paciente C</italic></bold>: 78 a&#241;os de edad, con lesi&#243;n de la clase B2, sometida a implante de un/ </p>
          <p><italic>stent</italic> Taxus</p>
          <p><sup>&#174;</sup> 2,75/32/ mm. El procedimiento se realiz&#243; en febrero de 2004 y el &#243;bito ocurri&#243; en agosto de 2005. &#211;bito s&#250;bito, domiciliar, por probable accidente isqu&#233;mico cerebral.</p>
        </list-item>
      </list>
      <p>La tasa de revascularizaci&#243;n de la lesi&#243;n tratada fue de 7,31% (15 pacientes). De esos pacientes 9 recibieron un nuevo <italic>stent</italic> farmacol&#243;gico y los dem&#225;s se trataron con angioplastia con cat&#233;ter bal&#243;n con l&#225;minas de titanio.</p>
      <p>
        <bold>An&#225;lisis univariado</bold>
      </p>
      <p>En este estudio, la variable respuesta considerada fue de al menos un evento card&#237;aco (presente o no) (<xref ref-type="table" rid="t4-body3">tab. 4</xref>).</p>
      <table-wrap id="t4-body3">
        <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt04-es.jpg"/></table-wrap>
      <p>
        <bold>An&#225;lisis multivariado</bold>
      </p>
      <p>En la <xref ref-type="table" rid="t5-body3">Tabla 5</xref>, est&#225;n presentados los valores de p resultantes del ajuste del modelo de regresi&#243;n log&#237;stica, al cual se incluyeron las variables consideradas en el estudio.</p>
      <table-wrap id="t5-body3">
        <graphic xlink:href="1678-4170-abc-92-01-0002-00002-gt05-es.jpg"/></table-wrap>
      <p>
        <bold>Discusi&#243;n</bold>
      </p>
      <p>Este estudio busc&#243; el seguimiento cl&#237;nico, a largo plazo (23,3&#177;10 meses de promedio), de pacientes sometidos a la angioplastia de la arteria descendente anterior con implante de un o m&#225;s <italic>stents</italic> farmaco-l&#243;gicos guiados por ultrasonido intravascular. La asociaci&#243;n de la t&#233;cnica del ultrasonido intravascular como gu&#237;a del implante del <italic>stent</italic> no farmacol&#243;gico permite la optimizaci&#243;n de la expansi&#243;n del stent, lo que reduce la restenosis tard&#237;a<sup>8</sup>. Por otra parte, en el implante de los <italic>stents</italic> farmacol&#243;gicos, los estudios cient&#237;ficos necesitan validar la utilizaci&#243;n del ultrasonido intravascular para selecci&#243;n u optimizaci&#243;n de la expansi&#243;n de los <italic>stents</italic>. Estudios randomi-zados con implante de <italic>stents</italic> farmacol&#243;gicos presentan resultados tard&#237;os distintos, que se relacionan directamente con las caracter&#237;sticas de las lesiones tratadas. El estudio Sirius<sup>3</sup> permiti&#243; la inclusi&#243;n de lesiones largas y vasos finos, elevando el &#237;ndice de restenosis tard&#237;a para el 8,9%, ubicada principalmente en los bordes de los <italic>stents</italic>, visto que la restenosis intrastent era peque&#241;a (3,2%).</p>
      <p>Los datos presentados plantean algunas cuestiones:</p>
      <list list-type="bullet">
        <list-item>
          <p>Si la elecci&#243;n de la extensi&#243;n de los </p>
          <p><italic>stents</italic> fuera guiada por ultrasonido, priorizando el recubrimiento de toda la extensi&#243;n de la placa responsable, &#191;los &#237;ndices de restenosis de bordos ser&#237;an los mismos?</p>
        </list-item>
        <list-item>
          <p>Pese al reconocimiento de los bajos &#237;ndices de restenosis intrastent de los </p>
          <p><italic>stents</italic> farmacol&#243;gicos, &#191;la optimizaci&#243;n de la expansi&#243;n de los </p>
          <p><italic>stents</italic> tendr&#237;a un impacto tard&#237;o positivo?</p>
        </list-item>
      </list>
      <p>Esas son preguntas dif&#237;ciles de ersponder porque implican muchas v&#237;as de la t&#233;cnica del implante de los <italic>stents</italic>, as&#237; como de la interpretaci&#243;n personal de las im&#225;genes del ultrasonido intravascular.</p>
      <p>El ultrasonido intravascular se utiliz&#243; en la evaluaci&#243;n pre implante del <italic>stent</italic> para an&#225;lisis de la extensi&#243;n de la placa ateroscler&#243;tica obstructiva, lo que permitir&#237;a que el <italic>stent</italic> elegido recubriera todo el segmento de la placa, quedando sus bordes en un segmento con menor carga de placa o sin lesi&#243;n ateroscler&#243;tica.</p>
      <p>Todos los <italic>stents</italic> implantados en la arteria descendente anterior tuvieron su expansi&#243;n optimizada en conformidad con la evaluaci&#243;n del ultrasonido intravascular. Independientemente de una &#243;ptima imagen angiogr&#225;fica, caso se observara, mediante el ultrasonido, que las pr&#243;tesis estaban mal expandidas, los <italic>stents</italic> se dilataban nuevamente.</p>
      <p>Con la evoluci&#243;n de los <italic>stents</italic> farmacol&#243;gicos &#151;que volvi&#243; posible un control adecuado de la proliferaci&#243;n neointimal&#151;, se verific&#243; que la p&#233;rdida tard&#237;a del di&#225;metro luminal intrastent no era baja solamente en los <italic>stents</italic> cortos (menores de 20 mm), sino que tambi&#233;n era muy baja en los <italic>stents</italic> largos<sup>11</sup>. Por esa acci&#243;n de los <italic>stents</italic> farmacol&#243;gicos largos, observada en los estudios cient&#237;ficos y en la pr&#225;ctica cl&#237;nica, se pas&#243; a valorizar a&#250;n m&#225;s la importancia del reconocimiento de la placa ateroscler&#243;tica, realizada por el ultrasonido, en la elecci&#243;n de la extensi&#243;n de los <italic>stents</italic>, de modo que se pudiera recubrir todo el segmento lesionado.</p>
      <p>En este estudio, la tasa global de (como m&#237;nimo uno) eventos card&#237;acos fue del 10,24%. Eventos como &#243;bito, cirug&#237;a de revascularizaci&#243;n e infarto agudo de miocardio fueron pocos, siendo que entre ellos la revascularizaci&#243;n de la lesi&#243;n tratada tuvo la tasa m&#225;s elevada (7,31%), correspondiente a 9/ pacientes que recibieron un nuevo <italic>stent</italic> farmacol&#243;gico, y a otros 6 pacientes sometidos a la dilataci&#243;n con cat&#233;ter bal&#243;n con l&#225;minas de titanio.</p>
      <p>La tasa de trombosis tard&#237;a fue del 0,48% por paciente &#243; del 0,33% por <italic>stent</italic>, en ella se incluyeron lesiones complejas, <italic>stents</italic> largos, <italic>stents</italic> m&#250;ltiples y lesiones en bifurcaciones, &#237;ndice muy bajo y semejante al encontrado en estudios con <italic>stent</italic> no farmacol&#243;gico<sup>12</sup>. La trombosis ocurri&#243; en un &#250;nico paciente, que suspendi&#243; el uso del clopidogrel en el cuarto mes, evolucionando con trombosis intrastent tras 15 d&#237;as.</p>
      <p>En esta serie, se trataron todas las clases de lesiones ateroscler&#243;ticas o de s&#237;ndromes cl&#237;nicas que implicaban la arteria descendente anterior, y los resultados evidenciaron que la tasa de sobrevida de esos pacientes es alta (98,54%). La restenosis cl&#237;nica (tasa de revascularizaci&#243;n de la lesi&#243;n tratada) fue el principal evento tard&#237;o observado en nuestros pacientes (7,31%). Sin embargo, la tasa de revascularizaci&#243;n de la lesi&#243;n tratada en esta investigaci&#243;n fue inferior a las tasas descritas en muchos estudios cl&#237;nicos.</p>
      <p>Los principales factores indicadores de eventos tard&#237;os fueron el area final evaluada por el ultrasonido y el n&#250;mero de <italic>stents</italic> implantados en la arteria descendente anterior. El di&#225;metro de referencia del vaso, la lesi&#243;n en bifurcaci&#243;n, los <italic>stents</italic> implantados en vasos finos (d"2,75) &#243; el tipo de <italic>stent</italic> implantado (Cypher<sup>&#174;</sup> o Taxus<sup>&#174;</sup>) no presentaron diferencia estad&#237;stica en el an&#225;lisis uni o multivariado.</p>
      <p>En el an&#225;lisis univariado realizado en la presente investigaci&#243;n, se observ&#243; que el &#225;rea luminal intrastent menor que 3,88/ mm<sup>2</sup> fue predictiva de eventos, con valor significativo de p (p = 0,0107). Los pacientes con &#225;rea luminal intrastent menor que 3,88 mm<sup>2</sup> en la evaluaci&#243;n final al ultrasonido presentaron mayor &#237;ndice de eventos, cuando comparados a los pacientes con &#225;reas luminales intrastent mayores que 3,88 mm<sup>2</sup> (21,28% vs. 6,96%, respectivamente, con p = 0,01). El tratamiento de lesiones largas implica la ubicaci&#243;n de los <italic>stents</italic> en los segmentos m&#225;s distales del vaso, lo que lleva a obtener un &#225;rea luminal bastante inferior a las &#225;reas obtenidas en el segmento m&#225;s proximal. Al implantarse correctamente esos <italic>stents</italic>, se verific&#243; la correcta ubicaci&#243;n de todas las astas de los <italic>stents</italic> a la pared del vaso, y tambi&#233;n si el &#225;rea luminal final correspondia a las &#225;reas luminales de referencia.</p>
      <p>Observamos que los <italic>stents</italic> con &#225;rea luminal final &gt; 3,88 mm2 por ultrasonido presentaron mejor evoluci&#243;n tard&#237;a (esta &#225;rea luminal corresponde al &#225;rea luminal m&#237;nima deseada en los segmentos considerados vasos finos). No obstante, el encuentro de un &#225;rea luminal final de 3,88 mm<sup>2</sup> en un segmento de vaso de gran calibre implica una pr&#243;tesis hipoexpandida, con astas sueltas en el interior de la luz del vaso, lo que puede interferir con el resultado tard&#237;o. Esta hip&#243;tesis no se analiz&#243; en esta casu&#237;stica, una vez que todos los <italic>stents</italic> se expandieron a su m&#225;ximo, con &#225;reas adecuadas al &#225;rea luminal de referencia proximal y distal.</p>
      <p>Un total de 31 pacientes recibi&#243; m&#225;s de un <italic>stent</italic> farmacol&#243;gico implantado en la arteria descendente anterior; de &#233;stos, la cantidad de 7 (22,58%) present&#243; un evento como m&#237;nimo. El implante de <italic>stents</italic> largos (promedio de la extensi&#243;n de los <italic>stents</italic> implantados en esta casu&#237;stica fue de 24,11) no fue un factor de incremento de riesgos tard&#237;os, adem&#225;s de que el implante de dos pr&#243;tesis hayar sido un factor independiente de eventos. Ese hallazgo fortalece la importancia de la disponibilidad de <italic>stents</italic> largos con presentaci&#243;n mayor de 30 mm de extensi&#243;n, lo que orienta al intervencionista a utilizar esos <italic>stents</italic> en vez de implantar dos pr&#243;tesis para el tratamiento de lesiones largas.</p>
      <p>Un hecho muy curioso se verific&#243; en este estudio: la &#250;nica caracter&#237;stica angiogr&#225;fica con p menor que 0,25/ mm fue la excentricidad de las lesiones (p = 0,18). Las lesiones conc&#233;ntricas fueron predictivas independientes de eventos, a la vez que las lesiones exc&#233;ntricas presentaron <italic>odd ratio</italic> de 0,24 (95% IC 0,07-0,81).</p>
      <p>En esta casu&#237;stica, las lesiones exc&#233;ntricas se mostraron como un indicativo protector contra eventos (p = 0,012, <italic>odd ratio</italic> 0,24 (95% IC 0,07-0,81)). Este hecho probablemente relacionado a la distribuci&#243;n de las astas del <italic>stent</italic>, que generalmente se separan al juntarse a la pared de menor resistencia, es decir, con menor cantidad de placa, y se agrupan en el lado de menor expansi&#243;n, que es el segmento con m&#225;s placa.</p>
      <p>El an&#225;lisis multivariado present&#243; tendencia estad&#237;stica de la diabetes como indicador independiente de eventos cardiacos; los no diab&#233;ticos presentaron un <italic>odd ratio</italic> de 0,31 (95% IC 0,10-1,02) (p = 0,0536), por tanto la diabetes no fue un fuerte predictor de eventos como se ha demostrado en la literatura. Este hecho puede estar relacionado a la caracter&#237;stica del grupo de pacientes no diab&#233;ticos que tambi&#233;n recibieron <italic>stents</italic> largos, lo que equipar&#243; la extensi&#243;n de malla met&#225;lica por vaso entre los grupos. Con el advenimiento de los <italic>stents</italic> farmacol&#243;gicos, se puede observar que los efectos protectores de los f&#225;rmacos tambi&#233;n se extienden a los pacientes diab&#233;ticos, que presentan evoluci&#243;n muy semejante a la de los pacientes no diab&#233;ticos. Sin embargo, no se puede afirmar todav&#237;a que es posible controlar por completo los eventos tard&#237;os de los pacientes diab&#233;ticos.</p>
      <p>Muchos estudios cl&#237;nicos demostraron la buena evoluci&#243;n obtenida con <italic>stents</italic> farmacol&#243;-gicos en vasos menores que 2,75/ mm (vasos finos). En esta serie, la tasa de eventos fue del 13,12% con el uso de <italic>stents</italic> menores que 3/ mm, y de 9,03% (p = 0,45) con <italic>stents</italic> mayores. Esa variable se estudi&#243; en la regresi&#243;n log&#237;stica por su relevancia como indicativo en los estudios con <italic>stents</italic> met&#225;licos. En el an&#225;lisis multivariado, se encontr&#243; un valor de p no significativo (p = 0,14).</p>
      <p>La casu&#237;stica estudiada representa la experiencia de un &#250;nico grupo, que tiene como caracter&#237;stica el uso frecuente del ultrasonido intracoronariano para guiar el implante de los <italic>stents</italic> farmacol&#243;gicos. Este estudio marca principalmente cuales son los pacientes libres de eventos (porcentaje de acierto del 99,5% mediante el modelo ajustado de la regresi&#243;n log&#237;stica).</p>
      <p>
        <bold>Conclusi&#243;n</bold>
      </p>
      <p>Tomando como base los datos obtenidos con esta investigaci&#243;n, concluimos que la revascularizaci&#243;n de la arteria descendente anterior con implante de <italic>stents</italic> farmacol&#243;gicos elegidos y optimizados por el ultrasonido intravascular presenta un bajo &#237;ndice de eventos tard&#237;os. El implante de dos <italic>stents</italic> farmacol&#243;gicos para el tratamiento de las lesiones largas fue el principal factor independiente para la ocurrencia de eventos tard&#237;os. El &#225;rea luminal final mayor que 3,88 mm2 que se obtuvo en los segmentos de peque&#241;os di&#225;metros de referencia es un indicador independiente de evoluci&#243;n libre de eventos.</p>
      <p>
        <bold>Potencial Conflicto de Intereses</bold>
      </p>
      <p>Declaro no haber conflicto de intereses pertinentes.</p>
      <p>
        <bold>Fuentes de Financiaci&#243;n</bold>
      </p>
      <p>El presente estudio no tuvo fuentes de financiaci&#243;n externas.</p>
      <p>
        <bold>Vinculaci&#243;n Acad&#233;mica</bold>
      </p>
      <p>Este art&#237;culo forma parte de tesis de Doctorado de Marcelo de Freitas Santos, por la</p>
      <p>Facultad de Ciencias M&#233;dicas de la Santa Casa de S&#227;o Paulo.</p>
      <p>
        <bold>Referencias</bold>
      </p>
    </body>
  </sub-article>
</article>