<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="other">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">QVwS9nLQvMVTwJtbwFvjp9F</article-id>
      <article-id pub-id-type="other">00027</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2007000300027</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(07)08800327</article-id>
      <article-id pub-id-type="doi">10.1590/S0066-782X2007000300027</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Atualiza&#231;&#227;o Cl&#237;nica</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Tratamento da respira&#231;&#227;o de Cheyne-Stokes em pacientes com insufici&#234;ncia card&#237;aca congestiva</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Freitas</surname>
            <given-names>Ivan Guerra de Ara&#250;jo</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Togeiro</surname>
            <given-names>S&#244;nia Maria Guimar&#227;es Pereira</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Tufik</surname>
            <given-names>S&#233;rgio</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <addr-line>
          <named-content content-type="city">S&#227;o Paulo</named-content>
          <named-content content-type="state">SP</named-content>
        </addr-line>
        <institution content-type="orgname">UNIFESP</institution>
        <institution content-type="orgdiv1">Escola Paulista de Medicina </institution>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>03</month>
        <year>2007</year>
      </pub-date>
      <volume>88</volume>
      <issue>3</issue>
      <fpage>e68</fpage>
      <lpage>e72</lpage>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <pub-date publication-format="electronic" date-type="pub">
        <day>21</day>
        <month>05</month>
        <year>2007</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>
      <bold>ATUALIZA&#199;&#195;O CL&#205;NICA</bold>
    </p>
    <p>Tratamento da respira&#231;&#227;o de Cheyne-Stokes em pacientes com insufici&#234;ncia card&#237;aca congestiva</p>
    <p>
      <bold>Ivan Guerra de Ara&#250;jo Freitas; S&#244;nia Maria Guimar&#227;es Pereira Togeiro; S&#233;rgio Tufik</bold>
    </p>
    <p> Escola Paulista de Medicina &#150; UNIFESP - S&#227;o Paulo, SP</p>
    <p>
      <xref ref-type="corresp" rid="end">Correspond&#234;ncia</xref>
    </p>
    <p><bold>Palavra-chave:</bold> Respira&#231;&#227;o de Cheyne-Stokes, insufici&#234;ncia card&#237;aca congestiva, hipocapnia.</p>
    <p>
      <bold>Introdu&#231;&#227;o</bold>
    </p>
    <p>A respira&#231;&#227;o de Cheyne-Stokes &#233; um evento presente em pacientes cardiopatas e com doen&#231;a neurol&#243;gica cerebral. Acomete aproximadamente 40% dos cardiopatas est&#225;veis com fra&#231;&#227;o de eje&#231;&#227;o (Fej) menor que 45%<sup>1</sup>. &#201; um sinal de gravidade da insufici&#234;ncia card&#237;aca, por estar associado a um aumento da estimula&#231;&#227;o simp&#225;tica, um conhecido fator de mau progn&#243;stico nesses pacientes<sup>2</sup>. Apesar de poder ser observada durante a vig&#237;lia, seu diagn&#243;stico &#233; feito por meio de polissonografia e consiste de:</p>
    <p>&#149; Pelo menos tr&#234;s ciclos consecutivos de uma altera&#231;&#227;o crescendo-decrescendo na amplitude respirat&#243;ria.</p>
    <p>&#149; Um ou ambos dos seguintes:</p>
    <p>a) &#205;ndice de apn&#233;ia/hipopn&#233;ia central maior ou igual a 5 por hora.</p>
    <p>b) A altera&#231;&#227;o c&#237;clica crescendo-decrescendo da amplitude respirat&#243;ria tem dura&#231;&#227;o de pelo menos 10 minutos consecutivos<sup>3 </sup>(<xref ref-type="fig" rid="fig01">fig.1</xref>).</p>
    <fig id="fig01">
      <graphic xlink:href="1678-4170-abc-88-03-0e68-00027-gf01.jpg"/></fig>
    <p>Os mecanismos que levam a respira&#231;&#227;o de Cheyne-Stokes (RCS) ainda n&#227;o foram completamente definidos. Sabe-se que esses pacientes s&#227;o hipoc&#225;pnicos, o que precipitaria o aparecimento de apn&#233;ias centrais. Especulam-se v&#225;rios motivos para essa hipocapnia/hiperventila&#231;&#227;o cr&#244;nica: maior sensibilidade dos quimiorreceptores respirat&#243;rios ao CO<sub>2</sub>; baixos estoques corp&#243;reos de O<sub>2</sub> levando a instabilidade respirat&#243;ria e hiperventila&#231;&#227;o; edema pulmonar intersticial em raz&#227;o de alta press&#227;o capilar pulmonar. O aumento do tempo circulat&#243;rio dos pacientes com insufici&#234;ncia card&#237;aca congestiva (ICC) tamb&#233;m &#233; implicado na fisiopatologia da RCS, j&#225; que o atraso na informa&#231;&#227;o da varia&#231;&#227;o da PaCO<sub>2</sub> do pulm&#227;o para os quimiorreceptores respirat&#243;rios provocaria a oscila&#231;&#227;o t&#237;pica desse tipo de respira&#231;&#227;o<sup>4</sup>.</p>
    <p>Em pesquisa sobre o assunto no Medline, o CPAP &#233; a modalidade mais estudada (40%). Oxigenioterapia compreende 16% das refer&#234;ncias. O tratamento da RCS visa combater a hip&#243;xia e os despertares noturnos presentes durante a respira&#231;&#227;o e que aumentam a atividade simp&#225;tica; melhorar a sonol&#234;ncia diurna e melhorar a fun&#231;&#227;o card&#237;aca. As modalidades terap&#234;uticas que veremos a seguir tentam atacar um dos prov&#225;veis mecanismos geradores da respira&#231;&#227;o (<xref ref-type="table" rid="tab01">tab.1</xref>).</p>
    <table-wrap id="tab01">
      <graphic xlink:href="1678-4170-abc-88-03-0e68-00027-gt01.jpg"/></table-wrap>
    <p>
      <bold>CPAP</bold>
    </p>
    <p>O CPAP (Continuous Positive Airway Pressure) j&#225; foi extensivamente comprovado como a modalidade terap&#234;utica de escolha na s&#237;ndrome de apn&#233;ia/hipopn&#233;ia obstrutiva do sono, na qual tem a fun&#231;&#227;o de evitar o colapso das vias a&#233;reas superiores. Entretanto, na RCS o CPAP tem outras fun&#231;&#245;es. Ele aumenta os estoques corp&#243;reos de O<sub>2</sub><sup>5</sup> mediante o incremento da capacidade residual funcional, al&#233;m de elevar a PaCO<sub>2</sub> por diminuir o volume corrente. Ao aumentar os estoques corp&#243;reos de O<sub>2</sub>, reduz a instabilidade respirat&#243;ria respons&#225;vel pelas varia&#231;&#245;es da respira&#231;&#227;o. A eleva&#231;&#227;o da PaCO<sub>2</sub> dificulta o aparecimento de apn&#233;ias centrais em raz&#227;o do aumento da diferen&#231;a entre o PaCO<sub>2</sub> do paciente e o PaCO<sub>2</sub> do limiar de apn&#233;ia. Krachman demonstrou os efeitos do CPAP nas reservas de O<sub>2</sub> corp&#243;reo. CPAP reduziu a velocidade de queda da satura&#231;&#227;o da oxi-hemoglobina (dSat/dt) provocada pelas apn&#233;ias, um valor que se correlaciona negativamente com as reservas corp&#243;reas de O<sub>2</sub><sup>5</sup>.</p>
    <p>A press&#227;o positiva em vias a&#233;reas tamb&#233;m age melhorando a fun&#231;&#227;o ventricular nos pacientes com ICC por diminuir a pr&#233; e a p&#243;s-carga. Naughton demonstrou que o CPAP reduz a press&#227;o transmural de ventr&#237;culo esquerdo (PTMVE = press&#227;o sist&#243;lica de ventr&#237;culo esquerdo &#150; press&#227;o esof&#225;gica) e o produto PTMVE sist&#243;lica x freq&#252;&#234;ncia card&#237;aca (um &#237;ndice de gera&#231;&#227;o de for&#231;a mioc&#225;rdica sist&#243;lica e consumo de O<sub>2</sub>) diminuindo a carga do ventr&#237;culo esquerdo (VE)<sup>6</sup>. Foi demonstrado tamb&#233;m que os pacientes cardiopatas com RCS t&#234;m congest&#227;o venosa pulmonar e press&#227;o intersticial elevada<sup>7</sup>, o que causa aumento da estimula&#231;&#227;o vagal aferente provocando hiperventila&#231;&#227;o. O CPAP tamb&#233;m combate o edema intersticial.</p>
    <p>Pelo fato de que grande parte desses pacientes ronca, o CPAP pode funcionar por diminuir a resist&#234;ncia de vias a&#233;reas. Nos roncadores, h&#225; uma queda maior na press&#227;o pleural e, portanto, maior pr&#233;-carga de ventr&#237;culo esquerdo, o que se corrige tornando as vias a&#233;reas mais p&#233;rveas com o CPAP.</p>
    <p>V&#225;rios estudos mostram os efeitos do CPAP na RCS de pacientes cardiopatas reduzindo o &#237;ndice de apn&#233;ia/hipopn&#233;ia (IAH) centrais<sup>2,5,8-12</sup>, melhorando a satura&#231;&#227;o da oxi-hemoglobina (SatO<sub>2</sub>) noturna<sup>2,8-10,12</sup>, diminuindo o tempo de sono em RCS<sup>9</sup> e o n&#250;mero de despertares breves<sup>9-12</sup>, incrementando assim a porcentagem de sono de ondas lentas<sup>9,12</sup>. Seus efeitos tamb&#233;m se mant&#234;m durante o dia, como observado na melhora da Fej de VE<sup>2,11,12</sup>, na classifica&#231;&#227;o de ICC da NYHA<sup>2,9,11,12</sup>, na redu&#231;&#227;o da sonol&#234;ncia diurna na escala de Epworth e queda da freq&#252;&#234;ncia card&#237;aca durante a vig&#237;lia<sup>11</sup>. Diminui a atividade simp&#225;tica reduzindo a concentra&#231;&#227;o da norepinefrina urin&#225;ria noturna e a concentra&#231;&#227;o de norepinefrina plasm&#225;tica matutina<sup>2</sup> e diminui a freq&#252;&#234;ncia de arritmias ventriculares<sup>10</sup>. Aumenta a sobrevida livre de transplante card&#237;aco e diminui a taxa de mortalidade/transplante card&#237;aco em trabalho que realizou seguimento por mais de dois anos<sup>13</sup>. Em rela&#231;&#227;o &#224; qualidade de vida, houve melhora na pontua&#231;&#227;o do "Chronic Heart Failure Questionaire" nos quesitos dispn&#233;ia, fadiga, bem-estar emocional e dom&#237;nio da doen&#231;a<sup>11</sup>.</p>
    <p>Nem todos os pacientes respondem ao CPAP. Javaheri<sup>10</sup> encontrou uma freq&#252;&#234;ncia de somente 43% de resposta (pacientes cujo IAH decresceu para menos que 15 por hora). Os "n&#227;o-respondedores" tinham um IAH m&#233;dio de 62, e os "respondedores", um IAH m&#233;dio de 36, o que mostra que os pacientes mais graves podem n&#227;o responder ao CPAP provavelmente porque esse pode levar a uma tend&#234;ncia a despertar, promovendo instabilidade respirat&#243;ria em raz&#227;o das press&#245;es mais elevadas usadas nesses pacientes. Outros estudos encontraram uma freq&#252;&#234;ncia maior de resposta, mas tinham uma popula&#231;&#227;o menos grave<sup>9</sup>.</p>
    <p>Contrariamente, outros autores mostram falha do CPAP em melhorar a RCS<sup>14,15</sup> ou mesmo que esse possa ser delet&#233;rio para esses pacientes<sup>15</sup>. Um erro metodol&#243;gico que pode ter contribu&#237;do para o insucesso do CPAP foi o protocolo utilizado no ajuste da press&#227;o, iniciada arbitrariamente em 7,5 cmH<sub>2</sub>O ou maior. Javaheri<sup>10</sup> e Naughton e cols.<sup>11</sup> elaboraram maneiras diferentes de titular a press&#227;o correta, mas ambos s&#227;o un&#226;nimes em iniciar a titula&#231;&#227;o com press&#227;o de 5 cmH<sub>2</sub>O e aumentar gradualmente a press&#227;o at&#233; um valor toler&#225;vel pelo paciente, tentando chegar entre 10 e 12 cmH<sub>2</sub>O. Outra poss&#237;vel explica&#231;&#227;o para aus&#234;ncia de efeitos ben&#233;ficos &#233; a avalia&#231;&#227;o do CPAP ap&#243;s somente uma noite de uso<sup>14</sup>. J&#225; foi demonstrado que os benef&#237;cios do CPAP s&#227;o conseguidos com o passar do tempo (h&#225; aumento da Fej em um e tr&#234;s meses de uso) e o n&#237;vel de press&#227;o tamb&#233;m pode ser otimizado durante o tratamento.</p>
    <p>Recentemente, um importante estudo multic&#234;ntrico<sup>16</sup> envolvendo 258 pacientes avaliou o uso do CPAP em longo prazo (24 meses) em cardiopatas. O resultado, por&#233;m, n&#227;o foi o esperado. Apesar de reduzir o &#237;ndice de apn&#233;ias centrais, aumentar a satura&#231;&#227;o da oxi-hemoglobina, melhorar a fun&#231;&#227;o card&#237;aca e reduzir os n&#237;veis de norepinefrina plasm&#225;tica, o CPAP falhou em demonstrar benef&#237;cio na mortalidade e na sobrevida livre de transplante. No in&#237;cio do estudo, a curva de sobrevida livre de transplante favoreceu o grupo controle, mas ap&#243;s 18 meses, passou a favorecer o grupo do CPAP, n&#227;o havendo diferen&#231;a estat&#237;stica no final do estudo. Esses resultados, que n&#227;o corroboraram expectativas geradas pelos estudos anteriores, podem decorrer do uso mais freq&#252;ente de betabloqueador em rela&#231;&#227;o aos mais antigos. A concomit&#226;ncia do uso do CPAP e betabloqueador limitou o potencial para melhorar a fun&#231;&#227;o ventricular obtida somente pelo CPAP.</p>
    <p>Um efeito adverso indesej&#225;vel do CPAP &#233; a diminui&#231;&#227;o do d&#233;bito card&#237;aco e conseq&#252;ente hipotens&#227;o arterial, que pode ser evitada com titula&#231;&#227;o da press&#227;o a partir de 5 cmH<sub>2</sub>O e eleva&#231;&#227;o gradual ao longo de dias ou semanas, conforme tolerado pelo paciente. Outra queixa comum &#233; o desconforto causado pela m&#225;scara nasal.</p>
    <p>Outro m&#233;todo de ventila&#231;&#227;o com press&#227;o positiva (ventila&#231;&#227;o assistida com dois n&#237;veis de press&#227;o, BiPAP) foi comparado ao CPAP, por&#233;m n&#227;o conferiu nenhuma vantagem sobre este, al&#233;m do seu custo proibitivo<sup>9</sup>.</p>
    <p>
      <bold>Oxig&#234;nio</bold>
    </p>
    <p>Os principais efeitos do O<sub>2</sub> na RCS s&#227;o: incremento dos estoques corp&#243;reos de O<sub>2</sub> prevenindo instabilidade dos gases arteriais e a remo&#231;&#227;o do est&#237;mulo hip&#243;xico para hiperpn&#233;ia permitindo que o PaCO<sub>2</sub> aumente alargando a diferen&#231;a entre o PaCO<sub>2</sub> do paciente e o PaCO<sub>2</sub> do limiar de apn&#233;ia<sup>17</sup>.</p>
    <p>Estudos mostram os v&#225;rios benef&#237;cios do O<sub>2</sub> na RCS: redu&#231;&#227;o do IAH<sup>8,18-22</sup>, melhora da SatO<sub>2</sub> noturna<sup>8,18-22</sup>, diminui&#231;&#227;o do tempo m&#233;dio de RCS<sup>18,21</sup> e dos despertares breves<sup>18,20,22</sup>, aumento do sono de ondas lentas<sup>18,22</sup>, redu&#231;&#227;o da freq&#252;&#234;ncia card&#237;aca durante a noite<sup>20</sup>. N&#227;o modificou sintomas<sup>20,21</sup>, por&#233;m melhorou um par&#226;metro de fun&#231;&#227;o cognitiva: a velocidade de processamento da informa&#231;&#227;o<sup>20</sup>. Reduziu a ativa&#231;&#227;o simp&#225;tica demonstrada pela diminui&#231;&#227;o da excre&#231;&#227;o urin&#225;ria noturna de noradrenalina<sup>21</sup>. Houve aumento do pico de consumo de O<sub>2 </sub>em teste de exerc&#237;cio com bicicleta<sup>20</sup>, que &#233; um forte preditor de mortalidade, o que leva a especula&#231;&#245;es sobre melhora da sobrevida com O<sub>2</sub>. Krachman e cols.<sup>8</sup> compararam O<sub>2</sub> com CPAP num estudo prospectivo randomizado com 25 pacientes e conclu&#237;ram que as duas modalidades s&#227;o igualmente efetivas, embora nesse estudo tanto o CPAP como o O<sub>2</sub> tenham sido usados somente por uma noite. Como j&#225; visto, o efeito do CPAP depende de um tempo prolongado de uso.</p>
    <p>O fluxo de O<sub>2</sub> usado nesses estudos variou de 2 a 4 l/min, e a taxa de resposta ao O<sub>2</sub> (porcentagem dos que tiveram o IAH reduzido para menos de 15 por hora) foi de 39%<sup>19</sup>. Como no caso do CPAP, os "respondedores" foram aqueles com RCS mais leve (menor IAH, dessatura&#231;&#227;o da oxi-hemoglobina mais leve e PaCO<sub>2</sub> maior).</p>
    <p>
      <bold>Teofilina</bold>
    </p>
    <p>O mecanismo pelo qual a teofilina age &#233; incerto. Sabe-se que &#233; inibidora da fosfodiesterase,mas nas concentra&#231;&#245;es utilizadas para tratamento da RCS n&#227;o tem esse efeito inibit&#243;rio. Em concentra&#231;&#245;es terap&#234;uticas, compete com a adenosina em alguns de seus receptores. No sistema nervoso central, a adenosina &#233; depressora respirat&#243;ria e a teofilina, por competir com ela, tem efeito estimulante respirat&#243;rio, evitando apn&#233;ias centrais.</p>
    <p>Demonstrou-se que a teofilina reduziu o IAH<sup>23,24</sup>, melhorou a SatO<sub>2</sub> noturna<sup>23,24</sup> e diminuiu os despertares breves totais<sup>24</sup> e associados a altera&#231;&#245;es respirat&#243;rias<sup>23</sup>. N&#227;o alterou efici&#234;ncia do sono, est&#225;gios do sono<sup>23,24</sup>, nem Fej de VE<sup>23</sup>. Tamb&#233;m n&#227;o alterou arritmias ventriculares, sugerindo ser uma op&#231;&#227;o segura nesses pacientes. &#201; importante saber que Javaheri e cols.<sup>23</sup> usaram O<sub>2</sub> nos pacientes em raz&#227;o da dessatura&#231;&#227;o da oxi-hemoglobina durante os exames, e isso pode ter contribu&#237;do para uma altera&#231;&#227;o nos resultados.</p>
    <p>As doses de teofilina utilizadas foram: 200-300 mg/dia (4,3 mg/kg de peso)<sup>24</sup> e 3,3 mg/kg de peso, duas vezes ao dia<sup>23</sup>. Seus defensores justificam seu uso enaltecendo as limita&#231;&#245;es das outras modalidades terap&#234;uticas: baixa ades&#227;o ao CPAP e possibilidade de remo&#231;&#227;o inadvertida da c&#226;nula de O<sub>2</sub> durante o sono.</p>
    <p>
      <bold>Outras op&#231;&#245;es</bold>
    </p>
    <p>1) Otimiza&#231;&#227;o da medica&#231;&#227;o para ICC: na verdade, essa deveria ser a primeira op&#231;&#227;o de tratamento, j&#225; que &#233; a mais simples. Walsh e cols.<sup>22</sup> demonstraram que pacientes com ICC est&#225;veis em uso de apenas furosemida evolu&#237;ram com aumento do sono de ondas lentas e sono REM, redu&#231;&#227;o do IAH e dos eventos de dessatura&#231;&#227;o, al&#233;m de incremento no CO<sub>2</sub> do final da expira&#231;&#227;o e redu&#231;&#227;o da ventila&#231;&#227;o-minuto ap&#243;s acr&#233;scimo de captopril 75 mg/dia durante um m&#234;s. Dark e cols.<sup>25</sup> estudaram pacientes que eram internados por descompensa&#231;&#227;o da insufici&#234;ncia card&#237;aca, mostrando anormalidades do padr&#227;o respirat&#243;rio (predominantemente apn&#233;ias centrais com RCS) em todos eles. Ap&#243;s compensa&#231;&#227;o da ICC durante a interna&#231;&#227;o com diur&#233;ticos, vasodilatadores, anti-hipertensivos, antiarr&#237;tmicos e inotr&#243;picos positivos foi realizada nova polissonografia com diminui&#231;&#227;o do IAH e tend&#234;ncia a melhora da SatO<sub>2</sub>.</p>
    <p>2) Marcapasso: o implante de marcapasso esquerdo ou biventricular com modo de desencadeamento atrial<sup>26</sup> mostrou redu&#231;&#227;o do IAH, melhora da SatO<sub>2</sub> e da qualidade subjetiva do sono, possivelmente por melhora da fun&#231;&#227;o card&#237;aca. Nesse estudo, nenhum paciente tinha indica&#231;&#227;o convencional de marcapasso.</p>
    <p>3) Benzodiazep&#237;nicos: a raz&#227;o para se usar benzodiazep&#237;nicos &#233; o efeito de aumento do limiar de despertar, j&#225; que esse &#233; decorrente da RCS e pode ser um fator perpetuante do problema, pela hiperventila&#231;&#227;o e hipocapnia conseq&#252;entes ao despertar. Estudos mostram redu&#231;&#227;o dos despertares breves, mas sem redu&#231;&#227;o significante do IAH nem da SatO<sub>2</sub> noturna<sup>27,28</sup>. Especial aten&#231;&#227;o deve ser dada ao paciente com apn&#233;ias obstrutivas, pois os benzodiazep&#237;nicos podem agrav&#225;-los.</p>
    <p>4) CO<sub>2</sub>: o uso de CO<sub>2 </sub>(0,2-1 l/min) misturado com O<sub>2</sub> (2l/min) durante o sono j&#225; foi estudado mostrando diminui&#231;&#227;o na dura&#231;&#227;o da RCS e melhora da SatO<sub>2</sub>, mas piorou a qualidade do sono e aumentou a atividade simp&#225;tica<sup>29</sup>. Al&#233;m disso, a hipercapnia resultante eleva a p&#243;s-carga ventricular esquerda e direita. Por esses motivos, n&#227;o deve ser indicada para pacientes com ICC.</p>
    <p>5) Servoventila&#231;&#227;o adaptativa: essa nova modalidade ventilat&#243;ria consiste de um vari&#225;vel suporte ventilat&#243;rio que se adapta dependendo da fase da respira&#231;&#227;o: maior nos per&#237;odos de apn&#233;ia e menor nos per&#237;odos de hiperventila&#231;&#227;o. Corrigiu a RCS, reduzindo objetivamente a sonol&#234;ncia diurna, os n&#237;veis plasm&#225;ticos de BNP (marcador de severidade da insufici&#234;ncia card&#237;aca) e a excre&#231;&#227;o de metadrenalina urin&#225;ria<sup>30</sup>. Melhorou qualidade do sono (aumentou tempo total de sono, efici&#234;ncia do sono, porcentagem de sono REM e de ondas lentas e diminuiu &#237;ndice de despertares breves), al&#233;m de reduzir IAH e dessatura&#231;&#245;es quando comparado com controle. Houve diferen&#231;as significativas de alguns desses par&#226;metros em compara&#231;&#227;o ao CPAP<sup>31</sup>.</p>
    <p>
      <bold>Conclus&#227;o</bold>
    </p>
    <p>Apesar de ser a modalidade mais estudada, a utiliza&#231;&#227;o do CPAP na RCS ainda &#233; controversa, e a experi&#234;ncia desse tratamento no Brasil ainda &#233; escassa, j&#225; que o CPAP n&#227;o &#233; fornecido gratuitamente e a maioria dos pacientes tem dificuldade de compr&#225;-lo. O O<sub>2</sub> &#233; uma op&#231;&#227;o no caso dos intolerantes ao CPAP, ou que, por outro motivo, n&#227;o possam us&#225;-lo. Por&#233;m, ainda n&#227;o foi avaliada a sobrevida em longo prazo dessa modalidade terap&#234;utica. Os outros tratamentos citados aqui necessitam de mais estudos. A RCS &#233; um evento freq&#252;ente nos cardiopatas e est&#225; associada a um pior progn&#243;stico, sendo, assim, importante o diagn&#243;stico e o tratamento corretos.</p>
    <p>
      <bold>Refer&#234;ncias</bold>
    </p>
    <p>1. Leung RST, Bradley TD. Sleep apnea and cardiovascular disease. Am J Respir Crit Care Med. 2001; 164: 2147-65.</p>
    <p>2. Naughton MT, Bernard DC, Liu PP, Rutheford R, Rankin F, Bradley TD. Effects of nasal CPAP on sympathetic activity in patients with heart failure and central sleep apnea. Am J Respir Crit Care Med. 1995; 152: 473-9.</p>
    <p>3. Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force. Sleep. 1999; 22: 667-84.</p>
    <p>4. Kellogg RH. Central chemical regulation of respiration. In: Fenn WO, Rahn H, eds. Handbook of physiology. Baltimore, MD: Williams &amp; Wilkens; 1964. p. 507-34.</p>
    <p>5. Krachman SL, Crocetti J, Berger TJ, Chatila W, Eisen HJ, D&#146;Alonzo GE. Effects of nasal continuous positive airway pressure on oxygen stores in patients with Cheyne-Stokes respiration and congestive heart failure. Chest. 2003; 123: 59-66.</p>
    <p>6. Naughton MT, Rahman MA, Hara K, Floras JS, Bradley TD. Effect of continuous positive airway pressure on intrathoracic and left ventricular transmural pressures in patients with congestive heart failure. Circulation. 1995; 91: 1725-31.</p>
    <p>7. Solin P, Bergin P, Richardson M, Kaye DM, Walters EH, Naughton MT. Influence of pulmonary capillary wedge pressure on central apnea in heart failure. Circulation. 1999; 99: 1574-9.</p>
    <p>8. Krachman SL, D&#146; Alonzo GE, Berger TJ, Eisen HJ. Comparison of oxygen therapy with nasal continuous positive airway pressure on Cheyne-Stokes respiration during sleep in congestive heart failure. Chest. 1999; 116: 1550-7.</p>
    <p>9. K&#246;hnlein T, Welte T, Tan LB, Elliott MW. Assisted ventilation for heart failure patients with Cheyne-Stokes respiration. Eur Respir J. 2002; 20: 934-41.</p>
    <p>10. Javaheri S. Effects of continuous positive airway pressure on sleep apnea and ventricular irritability in patients with heart failure. Circulation. 2000; 101: 392-7.</p>
    <p>11. Naughton MT, Liu PP, Bernard DC, Goldstein RS, Bradley TD. Treatment of congestive heart failure and Cheyne-Stokes respiration during sleep by continuous positive airway pressure. Am J Respir Crit Care Med. 1995; 151: 92-7.</p>
    <p>12. Takasaki Y, Orr D, Popkin J, Rutherford R, Liu P, Bradley TD. Effect of nasal continuous positive airway pressure on sleep apnea in congestive heart failure. Am Rev Respir Dis. 1989; 140: 1578-84.</p>
    <p>13. Sin DD, Logan AG, Fitzgerald FS, Liu PP, Bradley TD. Effects of continuous positive airway pressure on cardiovascular outcomes in heart failure patients with and without Cheyne-Stokes respiration. Circulation. 2000; 102: 61-6.</p>
    <p>14. Buckle P, Millar T, Kryger M. The effect of short-term nasal CPAP on Cheyne-Stokes respiration in congestive heart failure. Chest. 1992; 102: 31-5.</p>
    <p>15. Davies RJO, Harrington KJ, Ormerod OJM, Stradling JR. Nasal continuous positive airway pressure in chronic heart failure with sleep-disordered breathing. Am Rev Respir Dis. 1993; 147: 630-4. </p>
    <p>16. Bradley TD, Logan AG, Kimoff RJ, Series F, Morrison D, Ferguson K, et al. Continuous positive airway pressure for central sleep apnea and heart failure. N Engl J Med. 2005; 353: 2025-33.</p>
    <p>17. Berssenbrugge A, Dempsey J, Iber C, Skatrud J, Wilson P. Mechanisms of hypoxia-induced periodic breathing during sleep in humans. J Physiol. 1983; 343: 507-26.</p>
    <p>18. Hanly PJ, Millar TW, Steljes DG, Baert R, Frais MA, Kryger MH. The effect of oxygen on respiration and sleep in patients with congestive heart failure. Ann Intern Med. 1989; 111: 777-82.</p>
    <p>19. Javaheri S, Ahmed M, Parker TJ. Effects of nasal O2 on sleep-related disordered breathing in ambulatory patients with stable heart failure. Sleep. 1999; 22: 1101-6.</p>
    <p>20. Andreas S, Clemens C, Sandholzer H, Figulla HR, Kreuzer H . Improvement of exercise capacity with treatment of Cheyne-Stokes respiration in patients with congestive heart failure. J Am Coll Cardiol. 1996; 27: 1486-90.</p>
    <p>21. Staniforth AD, Kinnear WJM, Starling R, Hetmanski DJ, Cowley AJ. Effect of oxygen on sleep quality, cognitive function and sympathetic activity in patients with chronic heart failure and Cheyne-Stokes respiration. Eur Heart J. 1998; 19: 922-8.</p>
    <p>22. Walsh JT, Andrews R, Starling R, Cowley AJ, Johnston IDA, Kinnear WJ. Effects of captopril and oxygen on sleep apnoea in patients with mild to moderate congestive cardiac failure. Br Heart J. 1995; 73: 237-41.</p>
    <p>23. Javaheri S, Parker TJ, Wexler L, Liming JD, Lindower P, Roselle GA. Effect of theophylline on sleep-disordered breathing in heart failure. N Engl J Med. 1996; 335: 562-7.</p>
    <p>24. Hu K, Li QQ, Yang J, Hu SP, Chen XL. The effect of theophylline on sleep-disordered breathing in patients with stable chronic congestive heart failure. Chin Med J. 2003; 116: 1711-6.</p>
    <p>25. Dark DS, Pingleton SK, Kerby GR, Crabb JE, Gollub SB, Glatter TR, et al. Breathig pattern abnormalities and arterial oxygen desaturation during sleep in the congestive heart failure syndrome. Chest. 1987; 91: 833-6.</p>
    <p>26. Sinha AM, Skobel EC, Breithardt OA, Norra C, Markus KU, Breuer C, et al. Cardiac resynchronization therapy improves central sleep apnea and Cheyne-Stokes respiration in patients with chronic heart failure. J Am Coll Cardiol. 2004; 44: 68-71.</p>
    <p>27. Biberdorf DJ, Steens R, Millar TW, Kryger MH. Benzodiazepines in congestive heart failure: efects of temazepam on arousability and Cheyne-Stokes respiration. Sleep. 1993; 16: 529-38.</p>
    <p>28. Guilleminault C, Clerk A, Labanowski M, Simmons J, Stoohs R. Cardiac failure and benzodiazepines. Sleep. 1993; 16: 524-8.</p>
    <p>29. Andreas S, Weidel K, Hagenah G, Heindl S. Treatment of Cheyne-Stokes respiration with nasal oxygen and carbon dioxide. Eur Respir J. 1998; 12: 414-9.</p>
    <p>30. Pepperell JCT, Maskell NA, Jones DR, Langford-Wiley BA, Crosthwaite N, Stradling JA, et al. A randomized controlled trial of adaptive ventilation for Cheyne-Stokes breathing in heart failure. Am J Respir Crit Care Med. 2003; 168: 1109-14.</p>
    <p>31. Teschler H, D&#246;hring J, Wang Y, Berthon-Jones M. Adaptive pressure support servo-ventilation: a novel treatment for Cheyne-Stokes respiration in heart failure. Am J Respir Crit Care Med. 2001; 164: 614-9.</p>
    <p>
      <fn id="end" fn-type="corresp">
        <p>Correspond&#234;ncia:</p>
        <p> Ivan Guerra de Ara&#250;jo Freitas </p>
        <p> Rua Dr. Diogo de Faria, 1226/84 </p>
        <p> 04037-004 &#150; S&#227;o Paulo, SP </p>
        <p> E-mail: </p>
        <p>
          <email xlink:href="drivanguerra@gmail.com">drivanguerra@gmail.com</email>
        </p>
      </fn>
    </p>
    <p> Artigo recebido em 11/01/06; revisado recebido em 15/08/06; aceito em 09/10/06.</p>
  </body>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Clinical Update</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Treatment of Cheyne-Stokes respiration in patients with congestive heart failure</article-title>
      </title-group>
    </front-stub>
    <body>
      <p>
        <bold>CLINICAL UPDATE</bold>
      </p>
      <p> Treatment of Cheyne-Stokes respiration in patients with congestive heart failure</p>
      <p>
        <bold>Ivan Guerra de Ara&#250;jo Freitas; S&#244;nia Maria Guimar&#227;es Pereira Togeiro; S&#233;rgio Tufik</bold>
      </p>
      <p> Escola Paulista de Medicina &#150; UNIFESP - S&#227;o Paulo, SP - Brazil</p>
      <p>
        <xref ref-type="corresp" rid="end-body2">Mailing Address</xref>
      </p>
      <p><bold>Key words:</bold> Cheyne-Stokes respiration; heart failure, congestive; hypocapnia.</p>
      <p>
        <bold>Introduction</bold>
      </p>
      <p>Cheyne-Stokes respiration is an event observed in patients with cardiopathies and brain/neurological diseases. It affects around 40% of stable cardiopaths with an ejection fraction (EF) &lt; 45%<sup>1</sup>. It is a sign of heart failure severity, being associated to an increase in the sympathetic stimulation, which is a known poor prognosis factor in these patients<sup>2</sup>. Although it can be observed during the state of wakefulness, its diagnosis is achieved through polysomnography and consists of: </p>
      <p>- At least 03 consecutive cycles of an increasing-decreasing alteration in the respiratory range. </p>
      <p>- One or both of the following: </p>
      <p>a) Index of central apnea/ hypopnea <underline>&gt;</underline> 5 per hour. </p>
      <p>b) The increasing-decreasing cyclic alteration of the respiratory range lasts at least 10 consecutive minutes<sup>3 </sup>(<xref ref-type="fig" rid="fig01-body2">Figure 1</xref>).</p>
      <fig id="fig01-body2">
        <graphic xlink:href="1678-4170-abc-88-03-0e68-00027-gf01-en.jpg"/></fig>
      <p>The mechanisms that lead to Cheyne-Stokes respiration (CSR) have yet to be completely clarified. It is known that these patients are hypocapnic, which would cause the occurrence of central apnea. Several reasons for this chronic hypocapnia/hyperventilation are speculated: a higher sensibility of the respiratory CO<sub>2</sub> chemoreceptors; low body oxygen stores, leading to respiratory instability and hyperventilation; interstitial pulmonary edema due to high lung capillary pressure. The increase in the circulatory time of patients with congestive heart failure (CHF) is also implicated in the physiopathology of CSR, as the delayed information of the lung Pa<sub>CO2</sub> variation to the respiratory chemoreceptors would cause the typical oscillation of this type of respiration<sup>4</sup>.</p>
      <p>A research on the subject at MEDLINE showed that Continuous Positive Airway Pressure (CPAP) is the most studied modality (40%). Oxygen therapy comprises 16% of the References. The treatment of CSR aims at fighting hypoxia and the nocturnal awakenings present during the respiration, which increase the sympathetic activity, as well as improving diurnal somnolence and heart function. The therapeutic modalities that will be shown subsequently try to attack one of the probable mechanisms that generate the respiration (<xref ref-type="table" rid="tab01-body2">Table 1</xref>).</p>
      <table-wrap id="tab01-body2">
        <graphic xlink:href="1678-4170-abc-88-03-0e68-00027-gt01-en.jpg"/></table-wrap>
      <p>
        <bold>CPAP</bold>
      </p>
      <p>The CPAP has been extensively shown as the therapeutic modality of choice in Sleep Obstructive Apnea/Hypopnea Syndrome, where it has the function of preventing the collapse of the upper airways. However, in CSR, CPAP has other functions. It increases the body oxygen stores<sup>5</sup> through the increment of the functional residual capacity, in addition to increasing PaCO<sub>2</sub> by decreasing the current volume. By increasing the body oxygen stores of, it reduces the respiratory instability, which is responsible for the respiration variations. The elevation of PaCO<sub>2</sub> impairs the occurrence of central apneas due to the increase in the difference between the patient&#146;s PaCO<sub>2</sub> and the PaCO<sub>2 </sub>of the apnea threshold. Krachman demonstrated the effects of the CPAP on body stores of O<sub>2</sub>. CPAP diminished the velocity of the oxyhemoglobin saturation decline (dSat/dt) caused by the apneas, a value that correlates negatively with the body oxygen stores<sup>5</sup>. </p>
      <p>The positive pressure in the airways also acts by improving the ventricular function in patients with CHF by decreasing the pre- and post-load. </p>
      <p>Naughton demonstrated that CPAP reduces the left ventricle (LV) end-systolic transmural pressure (LVESTMP = systolic pressure of the left ventricle &#150; esophageal pressure) and the product LVESTMP x cardiac frequency (an index of systolic myocardial power generation and O<sub>2</sub> consumption), decreasing the LV load<sup>6</sup>. It has also been demonstrated that cardiopath patients with CSR have elevated pulmonary venous congestion and interstitial pressure<sup>7</sup>, which causes increased afferent vagal stimulation resulting in hyperventilation. CPAP also fights the interstitial edema.</p>
      <p>Due to the fact that many of these patients snore, CPAP can also act by decreasing the airway resistance. In snorers, there is a higher decrease in the pleural pressure and therefore, a higher LV pre-load, which is corrected by making the airways more pervious with CPAP.</p>
      <p>Several studies have shown the effects of CPAP on CSR of patients with cardiopathies, by reducing the central apnea/hypopnea index (AHI)<sup>2,5, 8-12</sup>, improving nocturnal oxyhemoglobin saturation (SatO<sub>2</sub>)<sup>2,8-10,12</sup>, decreasing the time of CSR during sleep<sup>9</sup> and the number of brief awakenings<sup>9-12</sup>, increasing the percentage of slow-wave sleep<sup>9,12</sup>. Its effects are also maintained during the day as observed in the LV EF improvement<sup>2,11,12</sup>, in the NYHA classification of CHF<sup>2,9,11,12</sup>, in the reduction of diurnal somnolence at the Epworth scale and decreased heart frequency during the state of wakefulness<sup>11</sup>. It also decreases the sympathetic activity by reducing the concentrations of nocturnal urinary norepinephrine and morning plasma norepinephrine<sup>2</sup> and decreases the frequency of ventricular arrhythmias<sup>10</sup>. It increases the heart transplant free-survival and decreases the mortality/heart transplant rate as shown in a study with more than 2 years of follow-up<sup>13</sup>. As for quality of life, there was improvement in the "Chronic Heart Failure Questionnaire" score regarding the items dyspnea, fatigue, emotional well-bring, and disease domain<sup>11</sup>.</p>
      <p>Not all patients respond to CPAP. Javaheri<sup>10</sup> found a frequency of only 43% of responders (patients whose AHI decreased to less than 15 per hour). The non-responders had a mean AHI of 62 and the responders, a mean AHI of 36, which shows that more severe patients may not respond to CPAP, probably due to the fact that the latter can lead to a tendency to wake up, promoting respiratory instability due to the more elevated pressures used in these patients. Other studies have found a higher frequency of responders, but they had less severe cohorts<sup>9</sup>. </p>
      <p>Contrarily, other authors have shown that CPAP failed to improve CSR<sup>14,15</sup>, or even showed that it can be deleterious for these patients<sup>15</sup>. A methodological error that might have contributed to the lack of success of CPAP was the protocol used in pressure adjustment, initiated arbitrarily at 7.5 cmH<sub>2</sub>O or higher.</p>
      <p>Javaheri<sup>10</sup> and Naughton et al<sup>11</sup> created different ways to titrate the correct pressure, but both are in agreement about starting the titration with a pressure of 5 cmH<sub>2</sub>O and increasing the pressure gradually until a value that is tolerable by the patient is reached, trying to achieve between 10 to 12 cmH<sub>2</sub>O. Another possible explanation for the absence of beneficial effects is the CPAP evaluation after just one night of its use<sup>14</sup>. It has been demonstrated that the benefits of CPAP are achieved with time (there is an increase in EF within 1 to 3 months of use) and the pressure level can also be optimized during treatment. </p>
      <p>Recently, an important multicentric study<sup>16</sup> that involved 258 patients evaluated long-term use (24 months) of CPAP in cardiopaths. The result, however, was not the expected one. Although it reduced the central apnea index, increased the oxyhemoglobin saturation, improved heart function and reduced the levels of plasma norepinephrine, CPAP failed in demonstrating benefits regarding mortality and transplant-free survival. </p>
      <p>In the beginning of the study, the transplant-free survival curve favored the control group, but 18 months later it started to favor the CPAP group, with no statistical difference at the end of the study. These results that did not corroborate the expectations generated by previous studies can be a consequence of more frequent beta-blocker use in comparison to the older ones. The concomitance of CPAP use and beta-blocker has limited the potential to improve the ventricular function obtained with CPAP alone. </p>
      <p>An undesirable adverse effect of CPAP is the cardiac output decrease and consequent arterial hypotension, which can be prevented with pressure titration from 5 cmH<sub>2</sub>O and its gradual elevation for days or weeks as tolerated by the patient. Another common complaint is the discomfort caused by the nasal mask.</p>
      <p>Another method of ventilation with positive pressure (Bi-level Positive Airway Pressure, BiPAP) was compared to CPAP, but did not show any advantage when compared to the latter, in addition to its very high cost<sup>9</sup>.</p>
      <p>
        <bold>Oxygen</bold>
      </p>
      <p>The main effects of O<sub>2</sub> on CSR are: increase of body oxygen stores, preventing the instability of arterial gases and the removal of the hypoxic stimulus to hyperpnea allowing the increase of PaCO<sub>2</sub>, augmenting the difference between the patient&#146;s PaCO<sub>2</sub> and the PaCO<sub>2</sub> of the apnea threshold<sup>17</sup>.</p>
      <p>Studies have shown the several benefits of O<sub>2</sub> in CSR: AHI reduction<sup>18-22</sup>, improvement of the nocturnal SatO<sub>2</sub><sup>8,18-22</sup>, decrease in the mean time of CSR<sup>18,21</sup> and brief awakenings<sup>18,20,22</sup>, increase of slow wave sleep<sup>18,22</sup>, reduction in cardiac frequency during the night<sup>20</sup>. It did not modify symptoms<sup>20,21</sup>, but improved a cognitive function parameter: the velocity of information processing<sup>20</sup>. It reduced the sympathetic activation demonstrated by the decrease of nocturnal urinary excretion of noradrenaline<sup>21</sup>. There was an increase in peak O<sub>2 </sub>consumption at the ergometric cycle test<sup>20</sup>, which is a strong predictor of mortality; this leads to speculations about the improvement of survival com O<sub>2</sub>. Krachman et al<sup>8</sup> compared O<sub>2</sub> with CPAP in prospective randomized study with 25 patients and concluded that the two modalities of treatment are equally effective, although in this study CPAP as well as O<sub>2</sub> were used for only one night. As seen before, CPAP effect depends on its long-term use. </p>
      <p>The O<sub>2</sub> flow used in these studies varied from 2 to 4 l/min and the response rate to O<sub>2</sub> (percentage of those who had the AHI reduced to &lt; 15 per hour) was 39%<sup>19</sup>. As with CPAP, the responders were those with milder CSR (lower AHI, milder oxyhemoglobin desaturation and higher PaCO<sub>2</sub>).</p>
      <p>
        <bold>Theophylline</bold>
      </p>
      <p>The mechanism through which Theophylline acts is uncertain. It is known that it inhibits phosphodiesterase, but at the concentrations used for the treatment of CSR, it does not have the inhibitory effect. At therapeutic concentrations, it competes with adenosine in some of its receptors. At the central nervous system (CNS), adenosine is a respiratory depressor and Theophylline has a respiratory stimulation effect as it competes with the first, preventing central apneas. </p>
      <p>It has been demonstrated that Theophylline reduced AHI<sup>23,24</sup>, improved nocturnal SatO<sub>2</sub><sup>23,24</sup> and decreased total brief awakenings<sup>24</sup> and those associated with respiratory alterations<sup>23</sup>. It did not alter sleep efficiency, sleep stages<sup>23,24</sup>, or LV EF<sup>23</sup>. Additionally, it did not alter ventricular arrhythmias, suggesting that it is a safe option for these patients. It is important to know that Javaheri et al<sup>23 </sup>used O<sub>2</sub> in patients due to oxyhemoglobin desaturation during examinations and this fact might have contributed to alterations in the results. </p>
      <p>The Theophylline doses used were: 200-300 mg/day (4.3 mg/kg)<sup>24</sup> and 3.3 mg/kg, twice a day<sup>23</sup>. Its defenders justify its use by mentioning the limitations of other therapeutic modalities: low adherence to CPAP and the possibility of inadvertently dislodging the O<sub>2</sub> cannula during sleep. </p>
      <p>
        <bold>Other options</bold>
      </p>
      <p>1) CHF drug therapy optimization: In fact, this should be the first-choice treatment, as it is the simplest. Walsh et al<sup>22</sup> demonstrated that patients with stable CHF with the use of furosemide alone, showed increase of slow wave sleep and REM sleep, reduction of HAI and desaturation events, as well as CO<sub>2</sub> increment at the end of the expiration and ventilation reduction a minute after the addition of captopril 75 mg/day for a month. Dark et al<sup>25</sup> studied patients who were admitted due to heart failure decompensation, showing respiratory pattern abnormalities (predominantly central apnea with CSR) in all of them. After CHF compensation during hospital stay with diuretics, vasodilators, antihypertensive drugs, antiarrhythmic drugs and positive inotropics, a new polysomnography was performed with decrease in AHI and a tendency of SatO<sub>2</sub>improvement.</p>
      <p>2) Pacemaker: Left or biventricular pacemaker implant with atrial trigger mode<sup>26</sup> showed a reduction in AHI and improvement in SatO<sub>2</sub> as well as in the subjective quality of sleep, possibly due to cardiac function improvement. In this study, no patient had a conventional indication of pacemaker.</p>
      <p>3) Benzodiazepine drugs: The reason for not using benzodiazepine drugs is the effect of increasing the awakening threshold, as it is a consequence of CSR and can be a perpetuating factor of the problem, due to hyperventilation and hypocapnia, caused by awakening. Studies have shown reduction of the brief awakenings, but no significant decrease in AHI or nocturnal SatO<sub>2</sub><sup>27,28</sup>. Special attention should be given to the patients with obstructive apneas, as the benzodiazepine drugs can aggravate them. </p>
      <p>4) CO<sub>2</sub>: The use of CO<sub>2</sub> (0.2-1 l/min) mixed with O<sub>2</sub> (2l/min) during sleep has been studied, and showed decrease in the duration of CSR and improvement in SatO<sub>2</sub>, but decreased the quality of sleep and increased the sympathetic activity<sup>29</sup>. Additionally, the resulting hypercapnia increases the left and right ventricular post-load. Therefore, it must not be indicated for patients with CHF. </p>
      <p>5) Adaptive servo-ventilation (ASV): This new ventilatory modality consists of a variable ventilatory support that adapts depending on the phase of the respiration, being higher in apnea and lower in hyperventilation periods. It corrected CSR, objectively reducing the diurnal somnolence, plasma BNP levels (a marker of heart failure severity) and the excretion of urinary metadrenaline<sup>30</sup>. It improved the quality of sleep (by increasing total sleep time, sleep efficiency, percentage of REM and slow wave sleep and decreasing the brief awakening index) and reduced AHI and desaturations, when compared to controls. There were significant differences in some of these parameters in comparison to CPAP<sup>31</sup>.</p>
      <p>
        <bold>Conclusion</bold>
      </p>
      <p>Although it is the most studied treatment modality, the use of CPAP in CSR is still controversial and the experience of this treatment in Brazil is still scarce, as CPAP is not provided by the public Health Services and most patients have difficulty to buy it. O<sub>2</sub> is an option for patients who are intolerant to CPAP or who cannot use it for any other reason. However, the long-term survival of this treatment modality has yet to be assessed. The other types of treatment reported here need further studies. CSR is a frequent event in cardiopaths and it is associated with a worse prognosis; thus, the correct diagnosis and treatment are of utmost importance.</p>
      <p>
        <bold>References</bold>
      </p>
      <p>1. Leung RST, Bradley TD. Sleep apnea and cardiovascular disease. Am J Respir Crit Care Med. 2001; 164: 2147-65.</p>
      <p>2. Naughton MT, Bernard DC, Liu PP, Rutheford R, Rankin F, Bradley TD. Effects of nasal CPAP on sympathetic activity in patients with heart failure and central sleep apnea. Am J Respir Crit Care Med. 1995; 152: 473-9.</p>
      <p>3. Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force. Sleep. 1999; 22: 667-84.</p>
      <p>4. Kellogg RH. Central chemical regulation of respiration. In: Fenn WO, Rahn H, eds. Handbook of physiology. Baltimore, MD: Williams &amp; Wilkens; 1964. p. 507-34.</p>
      <p>5. Krachman SL, Crocetti J, Berger TJ, Chatila W, Eisen HJ, D&#146;Alonzo GE. Effects of nasal continuous positive airway pressure on oxygen stores in patients with Cheyne-Stokes respiration and congestive heart failure. Chest. 2003; 123: 59-66.</p>
      <p>6. Naughton MT, Rahman MA, Hara K, Floras JS, Bradley TD. Effect of continuous positive airway pressure on intrathoracic and left ventricular transmural pressures in patients with congestive heart failure. Circulation. 1995; 91: 1725-31.</p>
      <p>7. Solin P, Bergin P, Richardson M, Kaye DM, Walters EH, Naughton MT. Influence of pulmonary capillary wedge pressure on central apnea in heart failure. Circulation. 1999; 99: 1574-9.</p>
      <p>8. Krachman SL, D&#146; Alonzo GE, Berger TJ, Eisen HJ. Comparison of oxygen therapy with nasal continuous positive airway pressure on Cheyne-Stokes respiration during sleep in congestive heart failure. Chest. 1999; 116: 1550-7.</p>
      <p>9. K&#246;hnlein T, Welte T, Tan LB, Elliott MW. Assisted ventilation for heart failure patients with Cheyne-Stokes respiration. Eur Respir J. 2002; 20: 934-41.</p>
      <p>10. Javaheri S. Effects of continuous positive airway pressure on sleep apnea and ventricular irritability in patients with heart failure. Circulation. 2000; 101: 392-7.</p>
      <p>11. Naughton MT, Liu PP, Bernard DC, Goldstein RS, Bradley TD. Treatment of congestive heart failure and Cheyne-Stokes respiration during sleep by continuous positive airway pressure. Am J Respir Crit Care Med. 1995; 151: 92-7.</p>
      <p>12. Takasaki Y, Orr D, Popkin J, Rutherford R, Liu P, Bradley TD. Effect of nasal continuous positive airway pressure on sleep apnea in congestive heart failure. Am Rev Respir Dis. 1989; 140: 1578-84.</p>
      <p>13. Sin DD, Logan AG, Fitzgerald FS, Liu PP, Bradley TD. Effects of continuous positive airway pressure on cardiovascular outcomes in heart failure patients with and without Cheyne-Stokes respiration. Circulation. 2000; 102: 61-6.</p>
      <p>14. Buckle P, Millar T, Kryger M. The effect of short-term nasal CPAP on Cheyne-Stokes respiration in congestive heart failure. Chest. 1992; 102: 31-5.</p>
      <p>15. Davies RJO, Harrington KJ, Ormerod OJM, Stradling JR. Nasal continuous positive airway pressure in chronic heart failure with sleep-disordered breathing. Am Rev Respir Dis. 1993; 147: 630-4. </p>
      <p>16. Bradley TD, Logan AG, Kimoff RJ, Series F, Morrison D, Ferguson K, et al. Continuous positive airway pressure for central sleep apnea and heart failure. N Engl J Med. 2005; 353: 2025-33.</p>
      <p>17. Berssenbrugge A, Dempsey J, Iber C, Skatrud J, Wilson P. Mechanisms of hypoxia-induced periodic breathing during sleep in humans. J Physiol. 1983; 343: 507-26.</p>
      <p>18. Hanly PJ, Millar TW, Steljes DG, Baert R, Frais MA, Kryger MH. The effect of oxygen on respiration and sleep in patients with congestive heart failure. Ann Intern Med. 1989; 111: 777-82.</p>
      <p>19. Javaheri S, Ahmed M, Parker TJ. Effects of nasal O2 on sleep-related disordered breathing in ambulatory patients with stable heart failure. Sleep. 1999; 22: 1101-6.</p>
      <p>20. Andreas S, Clemens C, Sandholzer H, Figulla HR, Kreuzer H . Improvement of exercise capacity with treatment of Cheyne-Stokes respiration in patients with congestive heart failure. J Am Coll Cardiol. 1996; 27: 1486-90.</p>
      <p>21. Staniforth AD, Kinnear WJM, Starling R, Hetmanski DJ, Cowley AJ. Effect of oxygen on sleep quality, cognitive function and sympathetic activity in patients with chronic heart failure and Cheyne-Stokes respiration. Eur Heart J. 1998; 19: 922-8.</p>
      <p>22. Walsh JT, Andrews R, Starling R, Cowley AJ, Johnston IDA, Kinnear WJ. Effects of captopril and oxygen on sleep apnoea in patients with mild to moderate congestive cardiac failure. Br Heart J. 1995; 73: 237-41.</p>
      <p>23. Javaheri S, Parker TJ, Wexler L, Liming JD, Lindower P, Roselle GA. Effect of theophylline on sleep-disordered breathing in heart failure. N Engl J Med. 1996; 335: 562-7.</p>
      <p>24. Hu K, Li QQ, Yang J, Hu SP, Chen XL. The effect of theophylline on sleep-disordered breathing in patients with stable chronic congestive heart failure. Chin Med J. 2003; 116: 1711-6.</p>
      <p>25. Dark DS, Pingleton SK, Kerby GR, Crabb JE, Gollub SB, Glatter TR, et al. Breathig pattern abnormalities and arterial oxygen desaturation during sleep in the congestive heart failure syndrome. Chest. 1987; 91: 833-6.</p>
      <p>26. Sinha AM, Skobel EC, Breithardt OA, Norra C, Markus KU, Breuer C, et al. Cardiac resynchronization therapy improves central sleep apnea and Cheyne-Stokes respiration in patients with chronic heart failure. J Am Coll Cardiol. 2004; 44: 68-71.</p>
      <p>27. Biberdorf DJ, Steens R, Millar TW, Kryger MH. Benzodiazepines in congestive heart failure: efects of temazepam on arousability and Cheyne-Stokes respiration. Sleep. 1993; 16: 529-38.</p>
      <p>28. Guilleminault C, Clerk A, Labanowski M, Simmons J, Stoohs R. Cardiac failure and benzodiazepines. Sleep. 1993; 16: 524-8.</p>
      <p>29. Andreas S, Weidel K, Hagenah G, Heindl S. Treatment of Cheyne-Stokes respiration with nasal oxygen and carbon dioxide. Eur Respir J. 1998; 12: 414-9.</p>
      <p>30. Pepperell JCT, Maskell NA, Jones DR, Langford-Wiley BA, Crosthwaite N, Stradling JA, et al. A randomized controlled trial of adaptive ventilation for Cheyne-Stokes breathing in heart failure. Am J Respir Crit Care Med. 2003; 168: 1109-14.</p>
      <p>31. Teschler H, D&#246;hring J, Wang Y, Berthon-Jones M. Adaptive pressure support servo-ventilation: a novel treatment for Cheyne-Stokes respiration in heart failure. Am J Respir Crit Care Med. 2001; 164: 614-9.</p>
      <p>
        <fn id="end-body2" fn-type="corresp">
          <label>
            <bold>Mailing Address:</bold>
          </label>
          <p> Ivan Guerra de Ara&#250;jo Freitas</p>
          <p> Rua Dr. Diogo de Faria, 1226/84</p>
          <p> 04037-004 &#150; S&#227;o Paulo, SP - Brazil</p>
          <p> E-mail: </p>
          <p>
            <email xlink:href="drivanguerra@gmail.com">drivanguerra@gmail.com</email>
          </p>
        </fn>
      </p>
      <p> Manuscript received January 11, 2006; revised manuscript received August 15, 2006; accepted October 9, 2006.</p>
      <p>10. Javaheri S. Effects of continuous positive airway pressure on sleep apnea and ventricular irritability in patients with heart failure. Circulation. 2000; 101: 392-7.</p>
    </body>
  </sub-article>
</article>
