<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">8CBxgZHKzrrMTX7WpsjDkSt</article-id>
      <article-id pub-id-type="other">00001</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2006000400001</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(06)08600401</article-id>
      <article-id pub-id-type="doi">10.1590/S0066-782X2006000400001</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Editorial</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Stents com elui&#231;&#227;o de sirolimus para tratamento de estenose em art&#233;rias coron&#225;rias de pequeno calibre: o que aprendemos?</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Costa</surname>
            <given-names>Ricardo A.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Lansky</surname>
            <given-names>Alexandra J.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <addr-line>
          <named-content content-type="city">Nova York</named-content>
          <named-content content-type="state">NY</named-content>
        </addr-line>
        <institution content-type="orgname">Columbia University Medical Center</institution>
        <institution content-type="orgdiv1">Cardiovascular Research Foundation </institution>
        <country country="US">USA</country>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>04</month>
        <year>2006</year>
      </pub-date>
      <volume>86</volume>
      <issue>4</issue>
      <fpage>245</fpage>
      <lpage>248</lpage>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <pub-date publication-format="electronic" date-type="pub">
        <day>25</day>
        <month>04</month>
        <year>2006</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>
      <bold>EDITORIAL</bold>
    </p>
    <p>Stents com elui&#231;&#227;o de sirolimus para tratamento de estenose em art&#233;rias coron&#225;rias de pequeno calibre: o que aprendemos?</p>
    <p>
      <bold>Ricardo A. Costa, MD; Alexandra J. Lansky, MD</bold>
    </p>
    <p>Cardiovascular Research Foundation and Columbia University Medical Center - Nova York, NY, USA</p>
    <p>
      <xref ref-type="corresp" rid="back10">Correspond&#234;ncia</xref>
    </p>
    <p>A interven&#231;&#227;o coronariana percut&#226;nea (ICP) em vasos de pequeno calibre (definida de maneira ampla como estenose em vaso com di&#226;metro de refer&#234;ncia inferior a 2,75-2,80 mm ou 3,00 mm)<sup>1,2</sup> tem sido historicamente associada a altas taxas de reestenose (18-52%) e revasculariza&#231;&#227;o do vaso (at&#233; 27%)<sup>1,3-5</sup>. Antes do advento dos <italic>stents</italic> revestidos com medicamentos, havia uma forte rela&#231;&#227;o entre reestenose e calibre do vaso, com uma associa&#231;&#227;o inversa entre o calibre do vaso e reestenose angiogr&#225;fica, atribu&#237;da &#224; quantidade desproporcionalmente maior de hiperplasia neointimal (HNI) em rela&#231;&#227;o ao calibre dos pequenos vasos<sup>1,3</sup>. Esse fen&#244;meno parecia ser agravado em diab&#233;ticos, que muitas vezes apresentam art&#233;rias "pequenas" em virtude de doen&#231;a coronariana difusa e exagerada resposta proliferativa neointimal<sup>4</sup>. Diversos estudos tentaram demonstrar a efic&#225;cia do implante de endopr&#243;teses em compara&#231;&#227;o com angioplastia transluminal coronariana (ATC) por bal&#227;o em vasos de pequeno calibre, mas os resultados foram controversos. Entretanto, uma recente metan&#225;lise de 11 estudos cl&#237;nicos randomizados (2.971 pacientes) comparou o uso de <italic>stents</italic> n&#227;o-revestidos com ATC por bal&#227;o em vasos de 2,22 a 2,60 mm, e os resultados demonstraram que o implante de endopr&#243;tese reduziu a reestenose (p = 0,003), com risco relativo de 0,77 (IC 95% 0,65, 0,92)<sup>1</sup>.</p>
    <p>Com a introdu&#231;&#227;o dos <italic>stents</italic> revestidos com sirolimus, muitos esperavam que a sua efic&#225;cia na preven&#231;&#227;o de reestenose em les&#245;es n&#227;o-complicadas fosse estendida para subgrupos de alto risco, como vasos pequenos. Em seu artigo para os <italic>Arquivos Brasileiros de Cardiologia</italic>, Devito e cols.<sup>6</sup> relataram os resultados obtidos com 80 pacientes inclu&#237;dos em um estudo prospectivo n&#227;o-randomizado que comparou o <italic>stent</italic> revestido com sirolimus (Cypher<sup>&#174;</sup>) com um <italic>stent</italic> n&#227;o-revestido (Multi-Link Pixel<sup>&#174;</sup>) no tratamento de les&#245;es coronarianas prim&#225;rias em vasos de 2,20 a 2,75 mm de di&#226;metro. Todas as endopr&#243;teses foram implantadas com sucesso, e as dimens&#245;es finais da luz foram semelhantes nos dois grupos. (&#201; importante observar que, nessa investiga&#231;&#227;o, os pacientes foram inclu&#237;dos consecutivamente em dois momentos distintos, e embora os dados cl&#237;nicos e demogr&#225;ficos iniciais fossem compat&#237;veis, os dois grupos n&#227;o eram totalmente homog&#234;neos em rela&#231;&#227;o a alguns crit&#233;rios importantes, como complexidade da les&#227;o e tamanho da endopr&#243;tese). No acompanhamento, perda tardia da luz (PTL), reestenose e &#225;rea de hiperplasia neointimal (HNI) foram reduzidas significativamente com o emprego de <italic>stent</italic> com sirolimus; al&#233;m disso, houve redu&#231;&#227;o de 3,5 vezes na revasculariza&#231;&#227;o da les&#227;o-alvo (RLA) com o uso de <italic>stent</italic> com sirolimus em compara&#231;&#227;o com <italic>stent</italic> comum, diferen&#231;a essa que n&#227;o alcan&#231;ou signific&#226;ncia estat&#237;stica.</p>
    <p>O desempenho do <italic>stent</italic> com sirolimus em "vasos pequenos" foi avaliado em v&#225;rios estudos cl&#237;nicos randomizados e registros (<xref ref-type="table" rid="t1">tab. 1</xref>). A PTL, um substituto da hiperplasia neointimal, foi reduzida de forma significativa com o uso de <italic>stent</italic> com sirolimus em vasos pequenos comparado com o <italic>stent</italic> comum, ficando em 98,7%, 78,8%, 81%, 88,2% e 82,2% nos estudos RAVEL, SIRIUS, E-SIRIUS, C-SIRIUS e SES-SMART, respectivamente<sup>2,5,7-10</sup>. No estudo de Devito, a PTL foi reduzida em 77,5%, p &lt; 0,001<sup>6</sup>. No SIRIUS-2.25, a PTL intra<italic>-stent</italic> foi ligeiramente mais elevada (0,36 mm) do que nos outros estudos (0,01-0,21 mm) (<xref ref-type="table" rid="t1">tab. 1</xref>). As porcentagens de diab&#233;ticos (40%) e les&#245;es complexas (B2/C) desse estudo eram maiores<sup>11</sup>. Os pacientes diab&#233;ticos tem demonstrado apresentar maior PTL do que os n&#227;o-diab&#233;ticos<sup>12,13.</sup> Na an&#225;lise de Devito, que tamb&#233;m tinha 40% de diab&#233;ticos por&#233;m les&#245;es menos complexas, a PTL foi de 0,25 mm<sup>6</sup>. De modo geral, as PTL foram compar&#225;veis &#224;s das les&#245;es em vasos de maior di&#226;metro tratados com <italic>stents</italic> revestidos com sirolimus<sup>7-9,14</sup> e consideravelmente menores do que as dos <italic>stents</italic> comuns (0,80-1,05 mm)<sup>2,5,7,10</sup>, confirmando a regularidade e efic&#225;cia dos <italic>stents</italic> com sirolimus na preven&#231;&#227;o de HNI, apesar das diferen&#231;as relativas &#224; porcentagem de pacientes diab&#233;ticos, ao calibre do vaso e &#224;s caracter&#237;sticas da les&#227;o.</p>
    <p content-type="asset">
      <table-wrap id="t1">
        <graphic xlink:href="1678-4170-abc-86-04-0245-00001-gt01.jpg"/></table-wrap>
    </p>
    <p>A cl&#225;ssica rela&#231;&#227;o inversa entre calibre do vaso e reestenose n&#227;o foi observada com o uso de <italic>stents</italic> com sirolimus no estudo RAVEL (0% de reestenose em todos os di&#226;metros de vaso)<sup>7</sup>. Entretanto, em uma suban&#225;lise do estudo SIRIUS (em que as les&#245;es eram mais extensas e mais complexas), as les&#245;es foram divididas em tercis de acordo com o calibre do vaso, e a porcentagem de reestenose intra<italic>-stent</italic> foi de 5%, 2,5% e 1,9% com o uso de <italic>stent</italic> com sirolimus em vasos pequenos (2,32 mm), m&#233;dios (2,78 mm) e grandes (3,31 mm). Da mesma forma, a porcentagem de reestenose no segmento do vaso-alvo foi maior em vasos pequenos (17,6%), em compara&#231;&#227;o com vasos m&#233;dios (6,6%) e grandes (1,9%)<sup>9</sup>. Conseq&#252;entemente, as redu&#231;&#245;es de risco de reestenose no segmento do vaso-alvo com o uso de <italic>stent</italic> com sirolimus ca&#237;ram para 93,7%, 81,7% e 58,8% em vasos grandes, m&#233;dios e pequenos, respectivamente. As taxas de reestenose do SIRIUS-2.25 foram compar&#225;veis &#224;s do tercil de "vasos pequenos" do SIRIUS e associadas com comprimento da endopr&#243;tese, diabetes e n&#250;mero de pr&#243;teses implantadas<sup>11</sup>. No artigo de Devito, houve 0% de reestenose intra<italic>-stent</italic> e apenas 4% de reestenose no segmento do vaso-alvo com <italic>stents</italic> com sirolimus, comparado com 33,3% de reestenose intra<italic>-stent</italic> e 36,7% de reestenose no segmento do vaso-alvo com o emprego de <italic>stent</italic> comum (p &lt; 0,001)<sup>6</sup>. Resultados semelhantes foram encontrados nos estudos RAVEL, E-SIRIUS, C-SIRIUS e SVELTE<sup>5,7,10,15</sup>. No RESEARCH, o calibre do vaso era consideravelmente menor do que nos outros estudos (<xref ref-type="table" rid="t1">tab. 1</xref>), e os casos de reestenose (apenas intra<italic>-stent</italic>) ocorreram principalmente ap&#243;s o tratamento de les&#245;es ostiais<sup>14</sup>. &#201; importante ressaltar que, na suban&#225;lise de diab&#233;ticos do SES-SMART, o <italic>stent</italic> com sirolimus foi associado com redu&#231;&#227;o significativa de PTL e reestenose, em compara&#231;&#227;o com o <italic>stent</italic> comum; entretanto, quando apenas os pacientes insulino-dependentes foram levados em considera&#231;&#227;o (35%), a taxa de reestenose com o uso de <italic>stent</italic> com sirolimus subiu para 40%<sup>12</sup>. Esses dados levam &#224;s seguintes considera&#231;&#245;es em rela&#231;&#227;o ao uso de <italic>stent</italic> com sirolimus em vasos pequenos: 1) as taxas de reestenose nos vasos pequenos s&#227;o mais elevadas do que nos vasos de maior calibre; 2) a reestenose parece aumentar de acordo com a gravidade da les&#227;o e &#225;rea coberta pela endopr&#243;tese; 3) pacientes diab&#233;ticos apresentam taxas mais altas de reestenose. Talvez isso se deva n&#227;o apenas &#224; resposta vascular hiperproliferativa e agressiva observada com freq&#252;&#234;ncia, mas tamb&#233;m ao implante sub-otimo do <italic>stent</italic> (cobertura incompleta da les&#227;o e expans&#227;o insuficiente do <italic>stent</italic>), uma vez que os diab&#233;ticos muitas vezes apresentam les&#245;es longas e difusas (como foi mencionado anteriormente); e 4) a taxa mais elevada de reestenose "no segmento do vaso-alvo" (comparado com reestenose "intra<italic>-stent</italic>") encontrada na maioria dos estudos (<xref ref-type="table" rid="t1">tab. 1</xref>) pode ser conseq&#252;&#234;ncia de cobertura incompleta da les&#227;o e/ou segmento lesado durante a realiza&#231;&#227;o de interven&#231;&#227;o coronariana percut&#226;nea. Esses problemas foram identificados por alguns autores<sup>8,16</sup>. Para a obten&#231;&#227;o de melhores resultados com vasos pequenos &#233; essencial o aprimoramento das t&#233;cnicas de aplica&#231;&#227;o dos "<italic>stents</italic> com elui&#231;&#227;o de medicamento" &#150; reduzindo ao m&#237;nimo o trauma da &#225;rea lesada com o emprego de bal&#245;es curtos de pr&#233;-dilata&#231;&#227;o, cobrindo toda a les&#227;o/segmento lesado, usando bal&#245;es curtos para a p&#243;s-dilata&#231;&#227;o (posicionados no interior da &#225;rea coberta para evitar les&#227;o al&#233;m das bordas dos <italic>stents</italic>) e efetuando uma aposi&#231;&#227;o completa, no caso de m&#250;ltiplas pr&#243;teses, evitando falhas.</p>
    <p>Estudos anteriores realizados com a utiliza&#231;&#227;o de ultra-som intracoronariano (USIC) demonstraram que o di&#226;metro luminal final em vasos com menos de 2,75 mm prev&#234; a necessidade de revasculariza&#231;&#227;o<sup>17</sup>. Resultados semelhantes foram encontrados com o uso de <italic>stents</italic> com sirolimus. No subestudo de USIC do SIRIUS, constatou-se que uma &#225;rea luminal m&#237;nima final intra<italic>-stent</italic> superior a 4,5 mm<sup>2</sup> em vasos com menos de 2,8 mm de di&#226;metro (por ACQ) representava um limiar que previa uma luz "adequada" pelo USIC no acompanhamento (&gt;4,0 mm<sup>2</sup>). O valor preditivo positivo das dimens&#245;es do <italic>stent</italic> pelo USIC foi de 90%<sup>18</sup>. Al&#233;m disso, Takebayashi e cols. relataram uma s&#233;rie de pacientes com fal&#234;ncia no vaso-alvo ap&#243;s implante de <italic>stent</italic> com sirolimus, a maioria (especialmente reestenose intra<italic>-stent</italic>) associada com subexpans&#227;o do <italic>stent</italic><sup>19</sup>. Isso era esperado, pois, uma vez que um medicamento que se mostrou eficaz (nesse caso, o sirolimus) inibiu a maior parte da hiperplasia neointimal (<xref ref-type="table" rid="t1">tab. 1</xref>), a principal causa de reestenose intra<italic>-stent</italic> passou a ser a subexpans&#227;o da endopr&#243;tese. Por fim, uma porcentagem maior de &#225;rea da placa e uma &#225;rea maior de borda do <italic>stent</italic>/&#225;rea luminal m&#237;nima de refer&#234;ncia foi associada com estenose da borda no grupo de <italic>stent</italic> com sirolimus do estudo SIRIUS<sup>20</sup>. Essas evid&#234;ncias indicam que a efic&#225;cia do <italic>stent</italic> com sirolimus depende da capacidade da pr&#243;tese de impedir a forma&#231;&#227;o de HNI e de uma t&#233;cnica de aplica&#231;&#227;o perfeita. No contexto dos vasos de pequeno calibre, a realiza&#231;&#227;o de ICP guiada por USIC para a coloca&#231;&#227;o de <italic>stents</italic> com sirolimus deve ser levada em considera&#231;&#227;o e at&#233; mesmo recomendada, pois apresenta algumas vantagens: 1) permite a avalia&#231;&#227;o precisa do di&#226;metro do vaso e da extens&#227;o da les&#227;o antes do procedimento, o que ajuda os operadores a selecionarem a t&#233;cnica e o dispositivo apropriados para a cobertura total da les&#227;o e o emprego de um <italic>stent</italic> de tamanho adequado; 2) ajuda a identificar uma expans&#227;o inadequada do <italic>stent</italic>, permitindo que o operador dilate posteriormente a endopr&#243;tese para obter a expans&#227;o ideal.</p>
    <p>Finalmente, o implante de <italic>stents</italic> com sirolimus em vasos pequenos tem sido associado com altas taxas de sucesso (&gt; 95%) e seguran&#231;a (compar&#225;veis &#224; de vasos maiores tratados com esses <italic>stents</italic>), refletindo-se na baixa incid&#234;ncia de trombose intra<italic>-stent</italic> e eventos cl&#237;nicos adversos maiores no acompanhamento de m&#233;dio e longo prazo (<xref ref-type="table" rid="t1">tab. 1</xref>)<sup>2,5,6,8,10,11,14,15</sup>. Al&#233;m disso, o <italic>stent</italic> com sirolimus levou a uma redu&#231;&#227;o relativa de 70% a 81% da RLA comparado com o <italic>stent</italic> comum em estudos cl&#237;nicos randomizados de "pequenos vasos"<sup>2,5,10</sup>. Um fato importante &#233; que as taxas de RLA e eventos cl&#237;nicos adversos maiores (<xref ref-type="table" rid="t1">tab. 1</xref>) foram extraordinariamente baixas em todos os estudos (&lt; 10%), sobretudo levando-se em considera&#231;&#227;o as les&#245;es de alto risco e as popula&#231;&#245;es de alto risco tratadas. Esses resultados confirmam o enorme impacto e os benef&#237;cios gerais do <italic>stent</italic> com sirolimus em compara&#231;&#227;o com <italic>stent</italic> comum e os importantes controles com ICP em vasos pequenos. No entanto, apesar do enorme avan&#231;o alcan&#231;ado nessa &#225;rea, o vaso de pequeno calibre ainda est&#225; associado com a ocorr&#234;ncia de reestenose ap&#243;s o implante de <italic>stent</italic> com sirolimus<sup>8</sup>. Portanto, ainda s&#227;o necess&#225;rios esfor&#231;os no sentido de melhorar os resultados, como aprimoramento da t&#233;cnica de aplica&#231;&#227;o dos <italic>stents</italic> e desenvolvimento de novas tecnologias espec&#237;ficas para vasos pequenos.</p>
    <p>
      <bold>REFER&#202;NCIAS</bold>
    </p>
    <p>1. Moreno R, Fernandez C, Alfonso F, Hernandez R, Perez-Vizcayno MJ, Escaned J et al. Coronary stenting versus balloon angioplasty in small vessels: a meta-analysis from 11 randomized studies. J Am Coll Cardiol. 2004;43:1964-72.</p>
    <p>2. Ardissino D, Cavallini C, Bramucci E, Indolfi C, Marzocchi A, Manari A et al. Sirolimus-eluting vs uncoated stents for prevention of restenosis in small coronary arteries: a randomized trial. Jama. 2004;292:2727-34.</p>
    <p>3. Holmes DR Jr, Kereiakes DJ. The approach to small vessels in the era of drug-eluting stents. Rev Cardiovasc Med. 2005;6 Suppl 1:S31-7.</p>
    <p>4. Saucedo JF, Popma JJ, Kennard ED, Talley JD, Lansky A, Leon MB et al. Relation of coronary artery size to one-year clinical events after new device angioplasty of native coronary arteries (a New Approach to Coronary Intervention [NACI] Registry Report). Am J Cardiol. 2000;85:166-71.</p>
    <p>5. Schampaert E, Cohen EA, Schluter M, Reeves F, Traboulsi M, Title LM et al. The Canadian study of the sirolimus-eluting stent in the treatment of patients with long de novo lesions in small native coronary arteries (C-SIRIUS). J Am Coll Cardiol. 2004;43:1110-5.</p>
    <p>6. Devito FS, Sousa AGMR, Feres F, Abizaid A, Staico R, Mattos LAP et al. Comparative Analysis of Intimal Hyperplasia After Sirolimus-Eluting Stent and Thin-Strut Bare Metal Stent Implantation in Small Coronary Arteries. Arq Bras Cardiol. 2006;86:268-75.</p>
    <p>7. Regar E, Serruys PW, Bode C, Holubarsch C, Guermonprez JL, Wijns W et al. Angiographic findings of the multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL): sirolimus-eluting stents inhibit restenosis irrespective of the vessel size. Circulation. 2002;106:1949-56.</p>
    <p>8. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003;349:1315-23.</p>
    <p>9. Popma JJ, Leon MB, Moses JW, Holmes DR Jr, Cox N, Fitzpatrick M et al. Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries. Circulation. 2004;110:3773-80.</p>
    <p>10. Schofer J, Schluter M, Gershlick AH, Wijns W, Garcia E, Schampaert E et al. Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS). Lancet. 2003;362:1093-9.</p>
    <p>11. Nikolsky E, Moses JW, Cambier P, Bachinsky B, O' Shaughnessy C, Mehran R et al. Results from the 2.25mm Sirolimus-Eluting BS Velocity Stent Registry in Patients with Native Coronary Artery Lesions. Am J Cardiol. 2005;96 (Suppl 7A):179H.</p>
    <p>12. Ortolani P, Ardissino D, Cavallini C, Bramucci E, Indolfi C, Aquilina M et al. Effect of sirolimus-eluting stent in diabetic patients with small coronary arteries (a SES-SMART substudy). Am J Cardiol. 2005;96:1393-8.</p>
    <p>13. Moussa I, Leon MB, Baim DS, O'Neill WW, Popma JJ, Buchbinder M et al. Impact of sirolimus-eluting stents on outcome in diabetic patients: a SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) substudy. Circulation. 2004;109:2273-8.</p>
    <p>14. Lemos PA, Arampatzis CA, Saia F, Hoye A, Degertekin M, Tanabe K et al. Treatment of very small vessels with 2.25-mm diameter sirolimus-eluting stents (from the RESEARCH registry). Am J Cardiol. 2004;93:633-6.</p>
    <p>15. Sousa JE. SVELTE: Multicenter, Controlled Study of Sirolimus-Eluting Stents in Small Vessels. Transcatheter Cardiovascular Therapeutics (TCT), Washington, DC [presentation]. <ext-link ext-link-type="uri" xlink:href="http://www.tctmd.com/csportal/appmanager/tctmd/main?_nfpb=true&amp;_pageLabel=TCTMDContent&amp;hdCon=814312.%202004">http://www.tctmd.com/csportal/appmanager/tctmd/main?_nfpb=true&amp;_pageLabel= TCTMDContent&amp;hdCon=814312. 2004</ext-link>.</p>
    <p>16. Lemos PA, Saia F, Ligthart JM, Arampatzis CA, Sianos G, Tanabe K et al. Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases. Circulation. 2003;108:257-60.</p>
    <p>17. Iakovou I, Mintz GS, Dangas G, Abizaid A, Mehran R, Lansky AJ et al. Optimal final lumen area and predictors of target lesion revascularization after stent implantation in small coronary arteries. Am J Cardiol. 2003;92:1171-6.</p>
    <p>18. Sonoda S, Morino Y, Ako J, Terashima M, Hassan AH, Bonneau HN et al. Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial. J Am Coll Cardiol. 2004;43:1959-63.</p>
    <p>19. Takebayashi H, Kobayashi Y, Mintz GS, Carlier SG, Fujii K, Yasuda T et al. Intravascular ultrasound assessment of lesions with target vessel failure after sirolimus-eluting stent implantation. Am J Cardiol. 2005;95:498-502.</p>
    <p>20. Sakurai R, Ako J, Morino Y, Sonoda S, Kaneda H, Terashima M et al. Predictors of edge stenosis following sirolimus-eluting stent deployment (a quantitative intravascular ultrasound analysis from the SIRIUS trial). Am J Cardiol. 2005;96:1251-3.</p>
    <p>
      <fn id="back10" fn-type="corresp">
        <label>
          <bold>Correspond&#234;ncia:</bold>
        </label>
        <p> Ricardo A. Costa </p>
        <p> 55 East 59th Street, 6th Floor </p>
        <p> New York, USA, 10022 </p>
        <p> E-mail: </p>
        <p>
          <email xlink:href="rcosta@crf.org">rcosta@crf.org</email>
        </p>
      </fn>
    </p>
    <p>Recebido em 22/02/06 </p>
    <p> Aceito em 22/02/06</p>
  </body>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Editorial</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Sirolimus-eluting stents for the treatment of stenoses in small coronary arteries: what have we learned?</article-title>
      </title-group>
    </front-stub>
    <body>
      <p>
        <bold>EDITORIAL</bold>
      </p>
      <p>Sirolimus-eluting stents for the treatment of stenoses in small coronary arteries: what have we learned? </p>
      <p>
        <bold>Ricardo A. Costa, MD; Alexandra J. Lansky, MD</bold>
      </p>
      <p>Cardiovascular Research Foundation and Columbia University Medical Center - Nova York, NY, USA</p>
      <p>
        <xref ref-type="corresp" rid="back10-body2">Mailing Address</xref>
      </p>
      <p>Percutaneous coronary intervention (PCI) in small vessels (broadly defined as stenosis in vessel with reference diameter &lt;2.75-2.80mm, or &lt;3.00mm)<sup>1,2</sup>, have been historically associated with high rates of restenosis (18-52%) and vessel revascularization (up to 27%)<sup>1,3-5</sup>. Prior to drug-eluting stents (DES), a strong correlation between restenosis and vessel size was recognized, with an inverse association between vessel size and angiographic restenosis; this was attributed to the disproportionately greater amount of neointimal hyperplasia (NIH) relative to the vessel caliber in smaller vessels<sup>1,3</sup>. This phenomenon seemed to be aggravated in diabetics who often present "small" arteries because of diffuse coronary disease and exaggerated neointimal proliferative response<sup>4</sup>. Several studies had attempted to demonstrate the efficacy of stenting versus balloon angioplasty in small vessels, but results were controversial. However, a recent meta-analysis of 11 randomized trials (2,971 patients) comparing bare metal stents (BMS) versus balloon angioplasty in vessels 2.22-2.60mm, demonstrated that restenosis was improved by stent implantation (p=0.003), with relative risk of 0.77 (95% confidence interval 0.65, 0.92)<sup>1</sup>.</p>
      <p>With the introduction of sirolimus-eluting stents (SES), many expected that the similar effectiveness of SES for preventing restenosis in uncomplicated lesions would extend to high risk subsets such as small vessels. In this issue of the <italic>Arquivos Brasileiros de Cardiologia</italic>, Devito et al<sup>6</sup> reports the outcomes of 80 patients enrolled in a prospective, non-randomized comparison between SES (Cypher<sup>&#174;</sup> stent) versus a BMS (ML-Pixel<sup>&#174;</sup> stent), for the treatment of <italic>de novo</italic> coronary lesions in vessels 2.20-2.75mm in diameter. All stents were implanted successfully and final luminal dimensions were similar in both groups. (It is important to note that in this investigation, patients were consecutively enrolled at two different time points, and even though baseline clinical demographics were comparable, the two groups were not perfectly matched according to some important criteria, including lesion complexity and stent size.) At follow-up, late lumen loss (LLL), restenosis and NIH area were significantly reduced with SES; also, a 3.5-fold decrease in target lesion revascularization (TLR) was found in SES compared to BMS, a difference that did not reach statistical significance.</p>
      <p>The performance of SES in small vessels has been evaluated in several randomized clinical trials and registries (<xref ref-type="table" rid="en_28912t1-body2">Table 1</xref>). LLL, a surrogate of NIH, was significantly decreased with SES compared to BMS in "small vessels" by 98.7%, 78.8%, 81%, 88.2%, and 82.2% in RAVEL, SIRIUS, E-SIRIUS, C-SIRIUS, and SES-SMART, respectively<sup>2,5,7-10</sup>. In Devito's study, LLL was decreased by 77.5%, p&lt;0.001<sup>6</sup>. A slightly higher in-stent LLL (0.36mm) was found in SIRIUS-2.25 compared to the other studies (0.01-0.21mm) (<xref ref-type="table" rid="en_28912t1-body2">Table 1</xref>). SIRIUS-2.25 had increased rates of diabetics (40%) and complex lesions (71% B2/C) <sup>11</sup>. Diabetics have been demonstrated to have higher LLL compared to non-diabetics<sup>12,13</sup>. In Devito's analysis, which also had 40% of diabetes but less complex lesions, LLL was 0.25mm<sup>6</sup>. Overall, these LLL were comparable to the LLL found in lesions in larger vessels treated with SES<sup>7-9,14</sup>, and were considerably lower compared to BMS (0.80-1.05mm)<sup>2,5,7,10</sup>, confirming the consistency and effectiveness of SES in preventing NIH, despite differences in diabetes rates, vessel size and lesion characteristics.</p>
      <p content-type="asset">
        <table-wrap id="en_28912t1-body2">
          <graphic xlink:href="1678-4170-abc-86-04-0245-00001-gt01-en.jpg"/></table-wrap>
      </p>
      <p>The classic inverse relationship between vessel size and restenosis was not seen with SES in RAVEL (0% restenosis in all vessel sizes)<sup>7</sup>. But, in a sub-analysis of the SIRIUS trial (which had longer and more complex lesions), lesions were divided into tertiles according to vessel size, and in-stent restenosis was 5%, 2.5%, and 1.9% with SES in small (2.32mm), "medium" (2.78mm), and large (3.31mm) vessels. Conversely, in-segment restenosis was increased in small vessels (17.6%), compared to "medium" (6.6%), and large (1.9%) vessels<sup>9</sup>. As a result, the risk reductions for in-segment restenosis with SES decreased by 93.7%, to 81.7%, to 58.8% in large, "medium", and small vessels, respectively. In SIRIUS-2.25, restenosis rates were comparable to SIRIUS "small vessel" tertile, and was associated with stent length, diabetes and number of stents implanted<sup>11</sup>. In Devito's report, there was no in-stent restenosis and only 4% in-segment restenosis with SES compared to 33.3% in-stent and 36.7% in-segment restenosis with BMS (p&lt;0.001)<sup>6</sup>. Similar results were found in RAVEL, E- and C-SIRIUS, and SVELTE<sup>5,7,10,15</sup>. In RESEARCH, vessel size was considerably smaller compared to the other studies (<xref ref-type="table" rid="en_28912t1-body2">Table 1</xref>), and restenosis (only in-stent) occurred mostly after treatment of ostial lesions<sup>14</sup>. Importantly, in the SES-SMART sub-analysis in diabetics, SES was associated with significant decrease in LLL and restenosis compared to BMS; however, when considering only insulin dependents (35%), restenosis with SES rose to 40%<sup>12</sup>. These data convey some considerations regarding SES in small vessels, including: 1) small vessels experience higher restenosis rates compared to larger vessels; 2) restenosis appears to increase according to lesion severity and stented length; 3) diabetics may experience higher rates of restenosis. This may be related not only to the hyperproliferative and aggressive vascular response often observed, but also to suboptimal stent deployment (incomplete lesion coverage, inadequate stent expansion, see below), since diabetics frequently present with long and diffuse disease (as mentioned before); and 4) the higher "in-segment" restenosis (compared to "in-stent") observed in the majority of studies (<xref ref-type="table" rid="en_28912t1-body2">Table 1</xref>) may be reflecting incomplete lesion coverage and/or injured segment during PCI. This situation has been recognized<sup>8,16</sup> and improvement in the "DES" technique &#150; minimize peri-lesion trauma using short pre-dilatation balloons, complete lesion/injured segment coverage, short post-dilatation balloons (positioned within the stented area to prevent injury outside of the stent edges), and overlap multiple stents avoiding gaps, may be critical to optimize results in small vessels.</p>
      <p>Previous studies with IVUS demonstrated that final luminal dimensions in vessels &lt;2.75mm predict vessel revascularization<sup>17</sup>. Similar results were found with SES. In the IVUS sub-study of the SIRIUS trial, a final minimum stent area &gt;4.5mm<sup>2</sup> for vessels &lt;2.8mm (by QCA) was found to be a threshold that predicted an "adequate" IVUS lumen at follow-up (&gt;4.0mm<sup>2</sup>). The positive predictive value of the IVUS stent dimensions was 90%<sup>18</sup>. In addition, Takebayashi et al reported a series of patients with target vessel failure post-SES implantation where the majority of failures (especially in-stent restenosis) were associated with stent <italic>underexpansion</italic><sup>19</sup>. This is expected as once an effective drug, (in this case, sirolimus), inhibited most of the NIH (<xref ref-type="table" rid="en_28912t1-body2">Table 1</xref>), the main cause of in-stent restenosis became stent <italic>underexpansion</italic>. At last, a larger reference percentage of plaque area and a larger edge stent area/reference minimum lumen area were associated with edge stenosis with SES in SIRIUS<sup>20</sup>. These evidences suggest that successful SES is relied upon a combination of SES' ability to prevent NIH formation and optimal stenting technique. In the context of small vessels, IVUS guided PCI for SES implantation should be especially considered and even recommended, as it: 1) allows accurate assessment of vessel size and lesion length before the procedure, helping operators to selected the proper device and technical approach to achieve full lesion coverage and proper stented segment matching; and 2) may identify inadequate stent expansion, permitting the operator to post dilate the stent to achieve optimal stent expansion.</p>
      <p>Finally, implantation of SES in small vessels has been associated with a high procedural success rate (&gt;95%) and sustained safety (comparable to larger vessels treaded with SES), reflected by the low incidence of stent thrombosis and MACE during the mid- and long term follow-up (<xref ref-type="table" rid="en_28912t1-body2">Table 1</xref>)<sup>2,5,6,8,10,11,14,15</sup>. In addition, SES led to a 70% to 81% relative reduction of TLR compared to BMS in "small vessel" randomized trials<sup>2,5,10</sup>. Importantly, both TLR and MACE rates with SES (<xref ref-type="table" rid="en_28912t1-body2">Table 1</xref>) were remarkably low in all studies (&lt;10%), especially given the high-risk lesions treaded and the high-risk population. These results confirm the dramatic impact and overall benefits of SES compared to BMS and historical controls of PCI in small vessels. Nevertheless, despite the impressive progress obtained in the field, small vessel is still predictive of restenosis after SES implantation<sup>8</sup>; therefore, continued efforts, including optimize DES technique and development of novel DES technologies specifically designed for small vessels, are still needed to improve outcome.</p>
      <p>
        <bold>REFERENCES</bold>
      </p>
      <p>1. Moreno R, Fernandez C, Alfonso F, Hernandez R, Perez-Vizcayno MJ, Escaned J et al. Coronary stenting versus balloon angioplasty in small vessels: a meta-analysis from 11 randomized studies. J Am Coll Cardiol. 2004;43:1964-72.</p>
      <p>2. Ardissino D, Cavallini C, Bramucci E, Indolfi C, Marzocchi A, Manari A et al. Sirolimus-eluting vs uncoated stents for prevention of restenosis in small coronary arteries: a randomized trial. JAMA. 2004;292:2727-34.</p>
      <p>3. Holmes DR Jr, Kereiakes DJ. The approach to small vessels in the era of drug-eluting stents. Rev Cardiovasc Med. 2005;6 Suppl 1:S31-7.</p>
      <p>4. Saucedo JF, Popma JJ, Kennard ED, Talley JD, Lansky A, Leon MB et al. Relation of coronary artery size to one-year clinical events after new device angioplasty of native coronary arteries (a New Approach to Coronary Intervention [NACI] Registry Report). Am J Cardiol. 2000;85:166-71.</p>
      <p>5. Schampaert E, Cohen EA, Schluter M, Reeves F, Traboulsi M, Title LM et al. The Canadian study of the sirolimus-eluting stent in the treatment of patients with long de novo lesions in small native coronary arteries (C-SIRIUS). J Am Coll Cardiol. 2004;43:1110-5.</p>
      <p>6. Devito FS, Sousa AGMR, Feres F, Abizaid A, Staico R, Mattos LAP et al. Comparative Analysis of Intimal Hyperplasia After Sirolimus-Eluting Stent and Thin-Strut Bare Metal Stent Implantation in Small Coronary Arteries. Arq Bras Cardiol. 2006;86:268-75.</p>
      <p>7. Regar E, Serruys PW, Bode C, Holubarsch C, Guermonprez JL, Wijns W et al. Angiographic findings of the multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL): sirolimus-eluting stents inhibit restenosis irrespective of the vessel size. Circulation. 2002;106:1949-56.</p>
      <p>8. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003;349:1315-23.</p>
      <p>9. Popma JJ, Leon MB, Moses JW, Holmes DR Jr, Cox N, Fitzpatrick M et al. Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries. Circulation. 2004;110:3773-80.</p>
      <p>10. Schofer J, Schluter M, Gershlick AH, Wijns W, Garcia E, Schampaert E et al. Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS). Lancet. 2003;362:1093-9.</p>
      <p>11. Nikolsky E, Moses JW, Cambier P, Bachinsky B, O' Shaughnessy C, Mehran R et al. Results from the 2.25mm Sirolimus-Eluting BS Velocity Stent Registry in Patients with Native Coronary Artery Lesions. Am J Cardiol. 2005;96 (Suppl 7A):179H.</p>
      <p>12. Ortolani P, Ardissino D, Cavallini C, Bramucci E, Indolfi C, Aquilina M et al. Effect of sirolimus-eluting stent in diabetic patients with small coronary arteries (a SES-SMART substudy). Am J Cardiol. 2005;96:1393-8.</p>
      <p>13. Moussa I, Leon MB, Baim DS, O'Neill WW, Popma JJ, Buchbinder M et al. Impact of sirolimus-eluting stents on outcome in diabetic patients: a SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) substudy. Circulation. 2004;109:2273-8.</p>
      <p>14. Lemos PA, Arampatzis CA, Saia F, Hoye A, Degertekin M, Tanabe K et al. Treatment of very small vessels with 2.25-mm diameter sirolimus-eluting stents (from the RESEARCH registry). Am J Cardiol. 2004;93:633-6.</p>
      <p>15. Sousa JE. SVELTE: Multicenter, Controlled Study of Sirolimus-Eluting Stents in Small Vessels. Transcatheter Cardiovascular Therapeutics (TCT), Washington, DC [presentation]. <ext-link ext-link-type="uri" xlink:href="http://www.tctmd.com/csportal/appmanager/tctmd/main?_nfpb=true&amp;_pageLabel=TCTMDContent&amp;hdCon=814312.%202004">http://www.tctmd.com/csportal/appmanager/tctmd/main?_nfpb=true&amp;_pageLabel= TCTMDContent&amp;hdCon=814312. 2004</ext-link>.</p>
      <p>16. Lemos PA, Saia F, Ligthart JM, Arampatzis CA, Sianos G, Tanabe K et al. Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases. Circulation. 2003;108:257-60.</p>
      <p>17. Iakovou I, Mintz GS, Dangas G, Abizaid A, Mehran R, Lansky AJ et al. Optimal final lumen area and predictors of target lesion revascularization after stent implantation in small coronary arteries. Am J Cardiol. 2003;92:1171-6.</p>
      <p>18. Sonoda S, Morino Y, Ako J, Terashima M, Hassan AH, Bonneau HN et al. Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial. J Am Coll Cardiol. 2004;43:1959-63.</p>
      <p>19. Takebayashi H, Kobayashi Y, Mintz GS, Carlier SG, Fujii K, Yasuda T et al. Intravascular ultrasound assessment of lesions with target vessel failure after sirolimus-eluting stent implantation. Am J Cardiol. 2005;95:498-502.</p>
      <p>20. Sakurai R, Ako J, Morino Y, Sonoda S, Kaneda H, Terashima M et al. Predictors of edge stenosis following sirolimus-eluting stent deployment (a quantitative intravascular ultrasound analysis from the SIRIUS trial). Am J Cardiol. 2005;96:1251-3.</p>
      <p>
        <fn id="back10-body2" fn-type="corresp">
          <label>
            <bold> Mailing Address:</bold>
          </label>
          <p> Ricardo A. Costa</p>
          <p> 55 East 59th Street, 6th Floor</p>
          <p> New York, USA, 10022</p>
          <p> E-mail: </p>
          <p>
            <email xlink:href="rcosta@crf.org">rcosta@crf.org</email>
          </p>
        </fn>
      </p>
      <p>Received on 02/22/06</p>
      <p> Accepted on 02/22/06</p>
    </body>
  </sub-article>
</article>