<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">6pzmGFYympVTGXKbjykYqGw</article-id>
      <article-id pub-id-type="other">00011</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2004001900011</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(04)08300011</article-id>
      <article-id pub-id-type="doi">10.1590/S0066-782X2004001900011</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigos Originais</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Estudo prospectivo e randomizado de pacientes tratados com e sem stents revestidos com carbeto de sil&#237;cio amorfo para a preven&#231;&#227;o da reestenose coronariana. Avalia&#231;&#227;o ultra-sonogr&#225;fica</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Tanajura</surname>
            <given-names>Luiz Fernando Leite</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Sousa</surname>
            <given-names>J. Eduardo M. R.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Sousa</surname>
            <given-names>Amanda G. M. R.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Abizaid</surname>
            <given-names>Alexandre</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Paula</surname>
            <given-names>Jo&#227;o Eduardo T.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Albertal</surname>
            <given-names>Mariano</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Feres</surname>
            <given-names>Fausto</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Mattos</surname>
            <given-names>Luiz Alberto P.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Staico</surname>
            <given-names>Rodolfo</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Pinto</surname>
            <given-names>Ibraim M.F.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <addr-line>
          <named-content content-type="state">S&#227;o Paulo</named-content>
        </addr-line>
        <institution content-type="orgname">Instituto Dante Pazzanese de Cardiologia</institution>
        <country country="BR">Brazil</country>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>12</month>
        <year>2004</year>
      </pub-date>
      <volume>83</volume>
      <issue>spe</issue>
      <fpage>59</fpage>
      <lpage>63</lpage>
      <history>
        <date date-type="accepted">
          <day>15</day>
          <month>09</month>
          <year>2004</year>
        </date>
        <date date-type="received">
          <day>24</day>
          <month>06</month>
          <year>2004</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <abstract>
        <p>OBJETIVO: A reestenose intra-stent &#233; a maior limita&#231;&#227;o das interven&#231;&#245;es coron&#225;rias percut&#226;neas. O carbeto de sil&#237;cio amorfo (SiC-a), subst&#226;ncia antitromb&#243;tica e antiinflamat&#243;ria capaz de reduzir a deposi&#231;&#227;o de fibrina, plaquetas e leuc&#243;citos sobre o stent, apresenta potencial de prevenir a hiperplasia neo-intimal e a reestenose. M&#201;TODOS: Estudo prospectivo, randomizado e tipo r&#243;tulo aberto comparando pacientes com doen&#231;a coronariana tratados com e sem stents revestidos com o SiC-a, utilizando a angiografia quantitativa e o ultra-som intracoron&#225;rio. Foram inclu&#237;dos 100 pacientes (50 em cada grupo) a fim de mensurar o volume de hiperplasia neo-intimal intra-stent/extremidades. Como os stents comparados apresentavam extens&#245;es diferentes, o volume de hiperplasia foi analisado em valores absolutos (por paciente) e relativos (por mil&#237;metro de extens&#227;o do stent). Avaliaram-se ainda os eventos card&#237;acos maiores e os resultados da angiografia quantitativa. RESULTADOS: Os grupos apresentaram caracter&#237;sticas de base semelhantes. Todos os pacientes foram tratados com sucesso. No 6&#176; m&#234;s de evolu&#231;&#227;o foram reestudados 94% dos casos dos dois grupos, obtendo-se ultra-som em 92%. O volume de hiperplasia neo-intimal absoluto foi significativamente maior nos tratados com os stents revestidos (51.2 DP 18.8 mm&#179; vs 41.9 DP 16.4 mm&#179;; p=0.014), por&#233;m o relativo foi semelhante (2.9 DP 1.0 mm&#179;/mm stent vs 2.5 DP 0.9 mm&#179;/mm stent; p=0.108). A obstru&#231;&#227;o volum&#233;trica da luz tamb&#233;m foi similar (36.4 DP 11.1% vs 37.9 DP 10.9%; p=0.505). O di&#226;metro m&#237;nimo da luz (1.9 DP 0.7 mm vs 1.8 DO 0.6 mm; p=0.552), a reestenose (19.1% vs 17%; p&gt;0.999) e a revasculariza&#231;&#227;o do vaso-alvo (16% vs 14%; p&gt;0.999) n&#227;o diferiram. CONCLUS&#195;O: Os stents revestidos apresentaram resultados cl&#237;nicos, angiogr&#225;ficos e ultra-sonogr&#225;ficos similares aos controles.</p>
      </abstract>
      <kwd-group xml:lang="pt" kwd-group-type="author-generated">
        <kwd>Reestenose</kwd>
        <kwd>doen&#231;a arterial coron&#225;ria</kwd>
        <kwd>angioplastia coron&#225;ria</kwd>
      </kwd-group>
      <pub-date publication-format="electronic" date-type="pub">
        <day>13</day>
        <month>12</month>
        <year>2004</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>
      <bold>ARTIGO ORIGINAL</bold>
    </p>
    <p>
      <bold>Estudo prospectivo e randomizado de pacientes tratados com e sem stents revestidos com carbeto de sil&#237;cio amorfo para a preven&#231;&#227;o da reestenose coronariana. Avalia&#231;&#227;o ultra-sonogr&#225;fica</bold>
    </p>
    <p>Luiz Fernando Leite Tanajura; J. Eduardo M. R. Sousa; Amanda G. M. R. Sousa; Alexandre Abizaid; Jo&#227;o Eduardo T. Paula; Mariano Albertal; Fausto Feres; Luiz Alberto P. Mattos; Rodolfo Staico; Ibraim M.F. Pinto </p>
    <p> S&#227;o Paulo, SP</p>
    <p>Instituto Dante Pazzanese de Cardiologia </p>
    <p>
      <xref ref-type="corresp" rid="end">Endere&#231;o para correspond&#234;ncia</xref>
    </p>
    <p>
      <bold>RESUMO</bold>
    </p>
    <p><bold>OBJETIVO: </bold>A reestenose intra-stent &#233; a maior limita&#231;&#227;o das interven&#231;&#245;es coron&#225;rias percut&#226;neas. O carbeto de sil&#237;cio amorfo (SiC-a), subst&#226;ncia antitromb&#243;tica e antiinflamat&#243;ria capaz de reduzir a deposi&#231;&#227;o de fibrina, plaquetas e leuc&#243;citos sobre o stent, apresenta potencial de prevenir a hiperplasia neo-intimal e a reestenose. </p>
    <p><bold>M&#201;TODOS: </bold>Estudo prospectivo, randomizado e tipo r&#243;tulo aberto comparando pacientes com doen&#231;a coronariana tratados com e sem stents revestidos com o SiC-a, utilizando a angiografia quantitativa e o ultra-som intracoron&#225;rio. Foram inclu&#237;dos 100 pacientes (50 em cada grupo) a fim de mensurar o volume de hiperplasia neo-intimal intra-stent/extremidades. Como os stents comparados apresentavam extens&#245;es diferentes, o volume de hiperplasia foi analisado em valores absolutos (por paciente) e relativos (por mil&#237;metro de extens&#227;o do stent). Avaliaram-se ainda os eventos card&#237;acos maiores e os resultados da angiografia quantitativa. </p>
    <p><bold>RESULTADOS:</bold> Os grupos apresentaram caracter&#237;sticas de base semelhantes. Todos os pacientes foram tratados com sucesso. No 6&#176; m&#234;s de evolu&#231;&#227;o foram reestudados 94% dos casos dos dois grupos, obtendo-se ultra-som em 92%. O volume de hiperplasia neo-intimal absoluto foi significativamente maior nos tratados com os stents revestidos (51.2 DP 18.8 mm<sup>3</sup> vs 41.9 DP 16.4 mm<sup>3</sup>; p=0.014), por&#233;m o relativo foi semelhante (2.9 DP 1.0 mm<sup>3</sup>/mm stent vs 2.5 DP 0.9 mm<sup>3</sup>/mm stent; p=0.108). A obstru&#231;&#227;o volum&#233;trica da luz tamb&#233;m foi similar (36.4 DP 11.1% vs 37.9 DP 10.9%; p=0.505). O di&#226;metro m&#237;nimo da luz (1.9 DP 0.7 mm vs 1.8 DO 0.6 mm; p=0.552), a reestenose (19.1% vs 17%; p&gt;0.999) e a revasculariza&#231;&#227;o do vaso-alvo (16% vs 14%; p&gt;0.999) n&#227;o diferiram. </p>
    <p><bold>CONCLUS&#195;O:</bold> Os stents revestidos apresentaram resultados cl&#237;nicos, angiogr&#225;ficos e ultra-sonogr&#225;ficos similares aos controles. </p>
    <p><bold>Palavras-chave: </bold>Reestenose, doen&#231;a arterial coron&#225;ria, angioplastia coron&#225;ria</p>
    <p> A partir de meados da &#250;ltima d&#233;cada, o implante dos stents coronarianos tornou-se a t&#233;cnica de revasculariza&#231;&#227;o percut&#226;nea mais utilizada em todo o mundo, em virtude de suas vantagens sobre as demais t&#233;cnicas, em rela&#231;&#227;o ao manejo de les&#245;es-alvo complexas, no controle das complica&#231;&#245;es na sala de cateterismo e, em especial, pela redu&#231;&#227;o da reestenose angiogr&#225;fica e da revasculariza&#231;&#227;o do vaso-alvo na evolu&#231;&#227;o cl&#237;nica tardia<sup>1,2</sup>. No entanto, a reestenose intra-stent, causa comum de recidiva da angina e da necessidade de procedimentos adicionais de revasculariza&#231;&#227;o, continua a restringir os benef&#237;cios cl&#237;nicos e econ&#244;micos advindos de sua utiliza&#231;&#227;o rotineira<sup>3,4</sup>. </p>
    <p>Como os stents virtualmente eliminaram a retra&#231;&#227;o el&#225;stica e o remodelamento cr&#244;nico, mecanismos claramente implicados na fisiopatologia da reestenose ap&#243;s interven&#231;&#245;es coronarianas percut&#226;neas (ICP) com o bal&#227;o ou as aterectomias, a causa b&#225;sica da reestenose intra-stent &#233; a hiperplasia neo-intimal<sup>5,6</sup>. Tentativas de preveni-la por meio de medicamentos administrados por via sist&#234;mica mostraram-se infrut&#237;feras<sup>2,4</sup>. Estudo recente associou significativamente os fen&#244;menos tromb&#243;ticos e inflamat&#243;rios &#224;s reobstru&#231;&#245;es ap&#243;s implante dos stents, o que n&#227;o foi observado ap&#243;s o uso do bal&#227;o<sup>7</sup>. Desta forma, o carbeto de sil&#237;cio amorfo (SiC-a), subst&#226;ncia inativa capaz de implementar a hemo e biocompatibilidade das endopr&#243;teses, em raz&#227;o de suas propriedades antitromb&#243;tica e antiinflamat&#243;ria, seria potencialmente capaz de reduzir a prolifera&#231;&#227;o neo-intimal e, em conseq&#252;&#234;ncia, a reestenose intra-stent<sup>8,9</sup>. O objetivo do estudo CERAMIC (<italic>randomized intravascular ultrasound comparison between endoprostheses with and without amorphous sIlicon-carbide for the prevention of coronary restenosis</italic>) foi comparar, utilizando o ultra-som intracoron&#225;rio e a angiografia coron&#225;ria quantitativa, os resultados tardios de stents com e sem este tipo de cobertura. </p>
    <p>
      <bold>M&#233;todos</bold>
    </p>
    <p>Esta investiga&#231;&#227;o foi prospectiva, randomizada e do tipo r&#243;tulo aberto.O protocolo foi aprovado pelo comit&#234; de &#233;tica em pesquisa da nossa Institui&#231;&#227;o. Todos os pacientes selecionados assinaram o termo de consentimento. O estudo foi elaborado em setembro de 1999 e a randomiza&#231;&#227;o ocorreu entre fevereiro e outubro de 2000. As angiografias coronarianas tardias foram realizadas entre agosto de 2001 e junho de 2002. </p>
    <p>Os crit&#233;rios de inclus&#227;o foram: 1) pacientes de ambos os sexos, com idade <underline>&gt;</underline> que 18 anos; 2) portadores de angina do peito est&#225;vel ou inst&#225;vel, isquemia mioc&#225;rdica silenciosa ou casos que evolu&#237;ssem assintom&#225;ticos ap&#243;s infarto do mioc&#225;rdio recente (&gt; 72h e &lt; 30 dias); 3) les&#227;o-alvo tipo <italic>de novo</italic>, em art&#233;rias coron&#225;rias naturais, com di&#226;metro de refer&#234;ncia entre 3.0 e 3.5mm e extens&#227;o inferior a 15mm; 4) di&#226;metro de estenose entre 50 e 99%, pela angiografia coronariana quantitativa; 5) ICP uniarterial, requerendo do tratamento de uma &#250;nica les&#227;o-alvo; 6) anatomia coronariana adequada para o implante de qualquer um dos stents designados pela randomiza&#231;&#227;o. Exclu&#237;ram-se os casos de: 1) infarto do mioc&#225;rdio nas &#250;ltimas 72h; 2) estenoses significativas (&gt; 50%) acometendo o tronco da coron&#225;ria esquerda; 3) les&#245;es ostiais a&#243;rticas e n&#227;o a&#243;rticas; 4) evid&#234;ncias angiogr&#225;ficas de trombo ou calcifica&#231;&#227;o acentuada; 5) estenoses em bifurca&#231;&#245;es que envolvessem ramos secund&#225;rios com di&#226;metro &gt; 2.0mm; 6) fra&#231;&#227;o de eje&#231;&#227;o ventricular global &lt; 30%; 7) antecedentes de alergia a aspirina, clopidogrel, ticlopidina, heparina ou a&#231;o inoxid&#225;vel. </p>
    <p>Os pacientes foram divididos em dois grupos: 1) grupo SiC-a - 50 casos tratados por um stent revestido pelo SiC-a (<italic>Teneo</italic><sup>&#174;</sup><italic>, Biotronik, Alemanha</italic>), nas extens&#245;es de 15 ou 20mm, com espessura das hastes de 0,08mm; 2) grupo controle - 50 pacientes nos quais implantaram-se stents convencionais (<italic>Bx Velocity</italic><sup>&#174;</sup><italic>, Cordis, Estados Unidos</italic>), nas extens&#245;es de 13 ou 18mm, com estrutura constitu&#237;da por hastes mais espessas (0,14mm). O revestimento dos stents Teneo<sup>&#174;</sup> &#233; feito utilizando a t&#233;cnica da deposi&#231;&#227;o de vapor qu&#237;mico por plasma aumentado, que origina uma camada com espessura de 0,08 mg da subst&#226;ncia inativa<sup>8</sup>. </p>
    <p>As ICP foram realizadas pela t&#233;cnica convencional de libera&#231;&#227;o &#243;tima, com pr&#233;-dilata&#231;&#227;o. Nos casos de dissec&#231;&#245;es remanescentes ou cobertura incompleta da les&#227;o-alvo, o protocolo permitia o implante de stents adicionais, preferencialmente iguais aos selecionados pela randomiza&#231;&#227;o. </p>
    <p>A farmacologia adjunta consistiu de: 1) heparina n&#227;o fracionada, na dose de 100UI/kg peso, administrada imediatamente antes do procedimento com o objetivo de atingir um tempo de coagula&#231;&#227;o ativado de 250s ou mais; 2) aspirina (200 mg/dia), iniciada pelo menos na v&#233;spera da interven&#231;&#227;o e mantida indefinidamente; 3) clopidogrel (dose de ataque de 300 mg, seguida por 75mg/dia) ou ticlopidina (500 mg/dia), ambas com pr&#233;-tratamento m&#237;nimo de um dia e utilizadas por 30 dias, com controle do hemograma a cada 15 dias. </p>
    <p>Ap&#243;s a alta hospitalar, os pacientes foram avaliados com 30 dias e seis meses de evolu&#231;&#227;o. As angiografias coronarianas tardias foram programadas para ser realizadas a partir do 6&#186; m&#234;s de evolu&#231;&#227;o, ou antes, se clinicamente indicados. Nessa ocasi&#227;o, todos os casos reestudados deveriam ser submetidos ao ultra-som intracoronariano. Qualquer revasculariza&#231;&#227;o adicional s&#243; poderia ser realizada em presen&#231;a de isquemia mioc&#225;rdica espont&#226;nea ou induzida. </p>
    <p>As imagens angiogr&#225;ficas foram obtidas em m&#250;ltiplas proje&#231;&#245;es, ap&#243;s administra&#231;&#227;o intracoronariana de nitratos. Sempre foi selecionada para an&#225;lise a proje&#231;&#227;o que apresentava o menor di&#226;metro m&#237;nimo da luz (DLM). Todos os dados foram analisados empregando-se o m&#233;todo de detec&#231;&#227;o autom&#225;tica de bordas. As vari&#225;veis foram mensuradas nas fases pr&#233;-implante, imediatamente p&#243;s-implante e na angiografia coronariana tardia. O DLM e a perda tardia da luz foram avaliados no segmento intra-stent e nas extremidades proximal e distal da endopr&#243;tese, considerando-se, respectivamente, a dist&#226;ncia de 5,0 mm antes e ap&#243;s o stent. Definiu-se sucesso do procedimento como les&#227;o residual &lt; 10% (visual), associada a aus&#234;ncia de complica&#231;&#245;es maiores hospitalares (&#243;bito, infarto e cirurgia de emerg&#234;ncia) e a reestenose pelo crit&#233;rio bin&#225;rio cl&#225;ssico (estenose igual ou superior a 50%); as reobstru&#231;&#245;es foram classificadas de acordo com a proposta de Mehran e cols<sup>10</sup>. </p>
    <p>Como os stents comparados apresentavam aspecto fluorosc&#243;picos diferentes (o <italic>Teneo<sup>&#174;</sup></italic> apresenta marcas de ouro nas extremidades), a an&#225;lise angiogr&#225;fica n&#227;o foi feita de forma cega. </p>
    <p>A an&#225;lise volum&#233;trica foi realizada por meio do programa de computa&#231;&#227;o <italic>Echoplaque</italic>, 2&#170; vers&#227;o (Indec Systems Inc., Estados Unidos), abrangendo o segmento intra-stent e as extremidades proximal e distal da endopr&#243;tese. Como este estudo comparou stents com extens&#245;es diferentes, no segmento intra-stent o volume de hiperplasia neo-intimal foi calculado em valores absolutos (por paciente) e relativos (por mil&#237;metro de segmento arterial coberto pelo metal); pelo mesmo motivo, tamb&#233;m foi mensurada a obstru&#231;&#227;o volum&#233;trica da luz (raz&#227;o entre o volume de hiperplasia neo-intimal e o volume do stent), com a finalidade de corrigir quaisquer distor&#231;&#245;es nos resultados que pudessem ocorrer em raz&#227;o das diferen&#231;as nas extens&#245;es dos stents. O recuo do cateter de ultra-som da por&#231;&#227;o distal &#224; les&#227;o at&#233; o &#243;stio do vaso foi realizado por meio de tra&#231;&#227;o autom&#225;tica, a uma velocidade constante de 0,5 mm/s. </p>
    <p>As extens&#245;es distintas das duas endopr&#243;teses tamb&#233;m impossibiliaram que a an&#225;lise do USIC fosse realizada de forma cega. </p>
    <p>O objetivo prim&#225;rio da investiga&#231;&#227;o foi mensurar o volume de hiperplasia neo-intimal no segmento que envolvia a endopr&#243;tese e as extremidades, aferido pelo USIC no sexto m&#234;s de evolu&#231;&#227;o, e os secund&#225;rios inclu&#237;ram: 1) taxa de reestenose bin&#225;ria; 2) DLM e perda tardia da luz; 3) revasculariza&#231;&#227;o do vaso-alvo e da les&#227;o-alvo; 4) eventos card&#237;acos maiores: &#243;bito, infarto do mioc&#225;rdio (com ou sem supradesnivelamento do segmento ST) e quaisquer revasculariza&#231;&#245;es adicionais realizadas na evolu&#231;&#227;o cl&#237;nica tardia. </p>
    <p>O c&#225;lculo do tamanho da amostra foi feito pelo m&#233;todo descrito por Armitage e Berry<sup>11</sup>. Estimando a m&#233;dia do volume de hiperplasia neo-intimal dos casos tratados com o stent Bx Velocity<sup>&#174;</sup> em 40 mm<sup>3</sup>, com desvio padr&#227;o de 20 mm<sup>3</sup>, m&#233;dia similar &#224; aferida com este modelo no estudo RAVEL<sup>12</sup>, calculou-se que seriam necess&#225;rios pelo menos 33 pacientes em cada grupo para detectar uma redu&#231;&#227;o de 30% ou mais deste valor nos pacientes tratados com os stents revestidos com o SiC-a, com poder do teste de 80%, hip&#243;tese monocaudal e n&#237;vel de signific&#226;ncia de 0,05. Prevendo-se eventuais perdas de seguimento e/ou recusa dos pacientes em serem submetidos ao estudo angiogr&#225;fico tardio, optou-se por incluir 50 casos em cada grupo. </p>
    <p>Os dados quantitativos foram expressos como m&#233;dia e desvio padr&#227;o (DP), enquanto os qualitativos, freq&#252;&#234;ncias absolutas e percentagens. A compara&#231;&#227;o entre as vari&#225;veis quantitativas foi feita por meio do teste t de Student; medidas que n&#227;o apresentassem distribui&#231;&#227;o normal foram analisadas pelo teste n&#227;o param&#233;trico de Mann-Whiteney. As vari&#225;veis qualitativas foram comparadas pelo teste do qui-quadrado com corre&#231;&#227;o de continuidade ou pelo teste exato de Fisher, quando necess&#225;rio. As avalia&#231;&#245;es foram feitas pelo princ&#237;pio da inten&#231;&#227;o de tratar. </p>
    <p>
      <bold>Resultados</bold>
    </p>
    <p>Os grupos n&#227;o apresentaram diferen&#231;as significativas em rela&#231;&#227;o &#224;s principais vari&#225;veis cl&#237;nicas e angiogr&#225;ficas (<xref ref-type="table" rid="tab01">tab. I</xref>). Angina inst&#225;vel do tipo IIIB da classifica&#231;&#227;o de Braunwald foi observada em cinco pacientes do grupo SiC-a e em quatro do grupo controle. A tienopiridina mais freq&#252;entemente prescrita foi a ticlopidina (96% versus 92%; p=0,678). </p>
    <table-wrap id="tab01">
      <graphic xlink:href="1678-4170-abc-83-spe-0059-00011-gt01.jpg"/></table-wrap>
    <p>Todos os 100 pacientes foram tratados com sucesso do procedimento sem necessidade da administra&#231;&#227;o de inibidores da glicoprote&#237;na IIb IIIa. Obteve-se revasculariza&#231;&#227;o completa em 32(64%) pacientes tratados com os stents revestidos e em 37(74%) controles (p=0,387). Stents com di&#226;metro de 3,5mm foram implantados na maior parte dos casos (56% vs 54%; p&gt;0,999). A necessidade do implante de endopr&#243;teses de forma n&#227;o planejada foi rara e semelhante nos dois grupos (2% vs 4%; p&gt;0,999), perfazendo um total de 51 (SiC-a) e 52 (controle) stents utilizados. A extens&#227;o m&#233;dia do segmento arterial coberto pelos stents tamb&#233;m foi similar (17,7 DP 4,0mm vs 16,7 DP 4,3mm; p=0,231). </p>
    <p>N&#227;o foram observados eventos na fase hospitalar e no 1&#186; m&#234;s de evolu&#231;&#227;o; tamb&#233;m n&#227;o ocorreram casos de trombose aguda ou subaguda. </p>
    <p>Todos os pacientes foram avaliados no 6&#186; m&#234;s de evolu&#231;&#227;o, em um per&#237;odo de tempo semelhante (6,1 meses versus 6,0 meses; p=0,691). Os eventos card&#237;acos maiores mostraram-se infrequentes e semelhantes em ambos os grupos. Houve um &#243;bito no grupo SiC-a (morte s&#250;bita, no 3&#186; m&#234;s de evolu&#231;&#227;o). Apenas um dos 15 pacientes que necessitou procedimentos adicionais de revasculariza&#231;&#227;o foi operado (grupo SiC-a), em decorr&#234;ncia de reestenose difusa proliferativa da por&#231;&#227;o proximal da art&#233;ria descendente anterior. Obteve-se sucesso do procedimento em todos os 14 casos tratados por meio de nova ICP. As revasculariza&#231;&#245;es da les&#227;o-alvo (14% vs 14%) e do vaso-alvo (16% vs 14%; p&gt;0,999) tamb&#233;m foram semelhantes. N&#227;o ocorreram eventos adversos n&#227;o cardiovasculares s&#233;rios. </p>
    <p>No 6&#186; m&#234;s de evolu&#231;&#227;o, 47(94%) casos de cada grupo foram submetidos &#224; angiografia coronariana de controle. Detectou-se reestenose em 9 (19,1%) pacientes do grupo SiC-a e em 8 (17,0%) do grupo controle (p&gt;0,999). As morfologias focais (44,4% vs 50,0%; p&gt;0,999) e difusas (56,6% vs 50,0%; p&gt;0,999) foram observadas de forma semelhante. </p>
    <p>A <xref ref-type="table" rid="tab02">tabela II</xref> exp&#245;e os resultados obtidos no segmento intra-stent e nas extremidades proximal e distal das endopr&#243;teses. Nas tr&#234;s localiza&#231;&#245;es, nas fases pr&#233;-ICP, p&#243;s-ICP e na angiografia coronariana tardia, o DLM e a perda tardia da luz n&#227;o apresentaram diferen&#231;as significativas. O ganho agudo e o ganho l&#237;quido intra-stent tamb&#233;m n&#227;o diferiram. </p>
    <table-wrap id="tab02">
      <graphic xlink:href="1678-4170-abc-83-spe-0059-00011-gt02.jpg"/></table-wrap>
    <p>O USIC foi realizado em 46(92%) pacientes de ambos os grupos. N&#227;o foi poss&#237;vel estudar um caso de cada grupo, em decorr&#234;ncia de dificuldades anat&#244;micas, que impossibilitaram o avan&#231;o do cateter de ultra-som. Dos 92 ultra-sons realizados, apenas um exame n&#227;o se mostrou adequado para an&#225;lise (grupo controle), por problemas de grava&#231;&#227;o, analisando-se 46 e 45 exames, respectivamente, nos grupos SiC-a e controle,. </p>
    <p>O volume de hiperplasia neo-intimal absoluto foi significativamente maior nos pacientes que receberam stents revestidos (51,2 DP 18,8 mm<sup>3</sup> versus 41,9 DP 16,4 mm<sup>3</sup>; p=0,014), n&#227;o confirmado pela mensura&#231;&#227;o em valores relativos (2,9 DP 1,0 mm<sup>3</sup>/mm stent versus 2,5 DP 0,9 mm<sup>3</sup>/mm stent; p=0,108). A obstru&#231;&#227;o volum&#233;trica da luz tamb&#233;m n&#227;o apresentou diferen&#231;as significativas (36,4 DP 11,1% vs 37,9 DP 10,9%; p=0,505). A an&#225;lise volum&#233;trica realizada nas extremidades proximal e distal das endopr&#243;teses demonstrou resultados similares entre os dois grupos, excluindo a possibilidade de efeito das bordas (<xref ref-type="table" rid="tab03">tab. III</xref>). N&#227;o foram observados casos de aposi&#231;&#227;o incompleta dos stents. </p>
    <table-wrap id="tab03">
      <graphic xlink:href="1678-4170-abc-83-spe-0059-00011-gt03.jpg"/></table-wrap>
    <p>
      <bold>Discuss&#227;o</bold>
    </p>
    <p>Esta investiga&#231;&#227;o demonstrou que o revestimento de stents coronarianos com o SiC-a n&#227;o reduziu a hiperplasia neo-intimal, mensurada pelo USIC, ap&#243;s procedimentos percut&#226;neos eletivos, em grupo de pacientes abrangendo, praticamente, todas as formas cl&#237;nicas de apresenta&#231;&#227;o da doen&#231;a coronariana. Em conseq&#252;&#234;ncia, a reestenose bin&#225;ria tamb&#233;m n&#227;o foi influenciada e nem as vari&#225;veis cl&#237;nicas (revasculariza&#231;&#227;o do vaso e da les&#227;o-alvo) e angiogr&#225;ficas (perda tardia da luz e di&#226;metro m&#237;nimo da luz) a ela associadas. </p>
    <p>A reestenose intra-stent restringe os benef&#237;cios tardios das ICP<sup>3,4,13</sup>, especialmente por ser a maior causa das revasculariza&#231;&#245;es adicionais no 1&#186; ano de evolu&#231;&#227;o. A hiperplasia neo-intimal, mecanismo patogen&#233;tico da reestenose intra-stent, origina-se de m&#250;ltiplos fatores, dentre os quais, as rea&#231;&#245;es tromb&#243;ticas e inflamat&#243;rias, conseq&#252;entes ao dano causado na parede vascular pela angioplastia<sup>14,15</sup>. Inoue e cols.<sup>9</sup>, comparando casos eletivos tratados com stent e com bal&#227;o, associaram significativamente a perda tardia da luz e a reestenose intra-stent aos fen&#244;menos tromb&#243;ticos e inflamat&#243;rios, o que n&#227;o ocorreu nas recidivas ap&#243;s uso do bal&#227;o. Essas observa&#231;&#245;es fortaleceram hip&#243;teses pr&#233;vias<sup>16</sup>, segundo as quais o trombo funcionaria como uma fonte praticamente inesgot&#225;vel de fatores de crescimento, predispondo as recidivas. </p>
    <p>Como nenhum medicamento antitromb&#243;tico ou antiproliferativo, administrado por via sist&#234;mica, mostrou-se capaz de prevenir o seu aparecimento, outras alternativas terap&#234;uticas t&#234;m sido investigadas<sup>16-18</sup>. </p>
    <p>Uma das linhas de pesquisa &#233; o revestimento dos stents utilizando subst&#226;ncias inativas, como o SiC-a, material semicondutor de eletricidade, que lhe confere potente a&#231;&#227;o antitromb&#243;tica<sup>8,9,16-18</sup>. Estudos experimentais demonstraram que, nas superf&#237;cies met&#225;licas, a trombose inicia-se pela transfer&#234;ncia de &#237;ons do fibrinog&#234;nio para o metal <sup>8,17</sup>. Por impedir ou dificultar essas rea&#231;&#245;es, esta subst&#226;ncia apresenta potencial de reduzir a trombose arterial em biometais<sup>9,17</sup>. Assim, implementando a bio e hemocompatibilidade das endopr&#243;teses, o SiC-a poderia interferir favoravelmente na cascata de rea&#231;&#245;es org&#226;nicas que gera a hiperplasia neo-intimal e a reestenose, reduzindo-as<sup>10,11,19</sup>. </p>
    <p>Recentemente, Monink e cols.<sup>9</sup> ratificaram a superior bio e hemocompatibilidade do SiC-a, utilizando um modelo experimental de circuito fechado que mimetizava a circula&#231;&#227;o sang&#252;&#237;nea, constitu&#237;do por silicone e acionado por uma bomba tipo rolete, avaliaram-se stents revestidos com SiC-a, recobertos com heparina e convencionais, de a&#231;o inoxid&#225;vel. Por meio de imunofluoresc&#234;ncia mensuraram-se, em cada tipo de pr&#243;tese, as liga&#231;&#245;es dos ant&#237;genos dos receptores da glicoprote&#237;na IIIa (de ades&#227;o plaquet&#225;ria) e CD 11B (de ades&#227;o dos leuc&#243;citos). Ambas as mensura&#231;&#245;es demonstraram redu&#231;&#245;es significativas dos dois ant&#237;genos nos stents revestidos pelo SiC-a, quando comparados aos demais, confirmando o potencial antitromb&#243;tico e antiinflamat&#243;rio desta subst&#226;ncia. </p>
    <p>Este estudo n&#227;o comprovou essa hip&#243;tese. Os resultados das principais vari&#225;veis cl&#237;nicas, angiogr&#225;ficas e ultra-sonogr&#225;ficas n&#227;o demonstraram vantagem significante dos stents revestidos em rela&#231;&#227;o aos convencionais; as duas endopr&#243;teses tamb&#233;m n&#227;o apresentaram efeitos nas bordas. </p>
    <p>Ao contr&#225;rio do esperado, os casos tratados com os stents revestidos apresentaram aumento significante do volume absoluto de hiperplasia intimal, provavelmente em decorr&#234;ncia da maior extens&#227;o destas pr&#243;teses, uma vez que o c&#225;lculo do volume &#233; feito pela soma das &#225;reas a cada mil&#237;metro de sua extens&#227;o. A hip&#243;tese de igualdade entre os dois tratamentos nos pareceu comprovada pelos resultados do volume relativo, que n&#227;o apresentou diferen&#231;a significativa, e, mais especificamente, pelo fato da obstru&#231;&#227;o do volume da luz, vari&#225;vel que corrige eventuais distor&#231;&#245;es associadas ao comprimento do stent, ter sido similar. </p>
    <p>A experi&#234;ncia cl&#237;nica com o revestimento de stents com o SiC-a ainda &#233; limitada. A literatura registra apenas experi&#234;ncias isoladas, sem angiografia coronariana de controle sistem&#225;tica na evolu&#231;&#227;o, dificultando uma avalia&#231;&#227;o precisa do seu potencial<sup>17-20</sup>. Apenas o estudo TRUST<sup>21</sup>, recentemente publicado, no qual foram comparados stents revestidos com este material frente a diversas endopr&#243;teses convencionais, na vig&#234;ncia de angina inst&#225;vel IIB e IIIB da classifica&#231;&#227;o de Braunwald, mostrou resultados sugestivos de redu&#231;&#227;o significativa nos eventos card&#237;acos maiores em seis meses, por&#233;m apenas no subgrupo que evolu&#237;a com angina inst&#225;vel IIIB (5.8% vs 15.3%; p=0.049), o que n&#227;o foi constatado nos demais casos. A grande restri&#231;&#227;o feita a esses resultados foi tratar-se de suban&#225;lise do estudo, o que torna esse achado potencialmente casual. </p>
    <p>Em nosso estudo, os resultados do grupo controle (<italic>stent Bx Velocity<sup>&#174;</sup></italic>), foram, em parte, semelhantes aos apresentados por esta pr&#243;tese em outros ensaios, como o RAVEL<sup>12</sup>, no qual a perda tardia da luz foi pr&#243;xima a 1,0mm e o volume de hiperplasia neo-intimal aferido pelo USIC em torno de 40,0mm<sup>3</sup>. Outras vari&#225;veis, por&#233;m, apresentaram achados discordantes, em especial a reestenose bin&#225;ria (17,0% vs 26,6%) e a revasculariza&#231;&#227;o do vaso-alvo (14% vs 22,8%), talvez devido ao fato do menor di&#226;metro de refer&#234;ncia pr&#233;-implante aferido no RAVEL (2.6mm vs 2.8mm), vari&#225;vel preditora independente de maiores taxas de reestenose<sup>22</sup>. </p>
    <p>Foram limita&#231;&#245;es: 1) al&#233;m do aspecto revestimento, outra diferen&#231;a relevante entre os stents comparados neste estudo foi a espessura das hastes, superior no <italic>Bx Velocity</italic><sup>&#174;</sup>, o que poderia ter influenciado os resultados, pois investiga&#231;&#227;o pr&#233;via que comparou endopr&#243;teses sob este prisma<sup>23</sup>, associou as hastes mais espessas a maiores taxas de reestenose e revasculariza&#231;&#227;o do vaso-alvo, possivelmente em decorr&#234;ncia de um maior grau de dano endotelial, n&#227;o reproduzido nesta investiga&#231;&#227;o; 2) como n&#227;o foram inclu&#237;dos no estudo pacientes com infarto do mioc&#225;rdio h&#225; menos de 72h, bem como os com les&#245;es de muito maior complexidade angiogr&#225;fica (reesten&#243;ticas, bifurca&#231;&#245;es, segmentares com extens&#227;o maior que 15mm), os resultados n&#227;o devem ser extrapolados para estas situa&#231;&#245;es; 3) o impacto nos com angina inst&#225;vel III de Braunwald, os que mais se beneficiariam do revestimento em quest&#227;o segundo o estudo TRUST<sup>21</sup>, n&#227;o p&#244;de ser precisamente estabelecido; 4) o fato das an&#225;lises angiogr&#225;fica e ultra-sonogr&#225;fica n&#227;o terem sido cegas pode, de alguma forma, ter interferido nos resultados. </p>
    <p>Em conclus&#227;o, nos pacientes tratados por meio de stents revestidos pelo SiC-a n&#227;o foram observadas vantagens cl&#237;nicas, angiogr&#225;ficas ou nos resultados do USIC, em compara&#231;&#227;o com os stents convencionais. Entretanto, os resultados similares observados entre os grupos tornam este modelo uma alternativa v&#225;lida em pacientes cujos perfis cl&#237;nico e angiogr&#225;fico assemelhem-se aos do nosso estudo.</p>
    <p>
      <fn id="end" fn-type="corresp">
        <p>Endere&#231;o para correspond&#234;ncia</p>
        <p> Dr. Luiz Fernando Leite Tanajura </p>
        <p> Rua Caiubi, 324/71 </p>
        <p> Cep 05010-000 &#150; S&#227;o Paulo &#150; SP </p>
        <p> E-mail - </p>
        <p>
          <email xlink:href="lfleite@cardiol.br">lfleite@cardiol.br</email>
        </p>
      </fn>
    </p>
    <p>Enviado para publica&#231;&#227;o em 24/06/2004 </p>
    <p> Aceito em 15/09/2004</p>
  </body>
  <back>
    <ref-list>
      <ref id="B1">
        <mixed-citation>1. Serruys PW, Jaegere P, Kiemeneij F, et al.    A comparison of balloon-expandable stent implantation with balloon angioplasty    in patients with coronary artery disease. N Engl J Med 1994; 331: 489-95. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>A comparison of balloon-expandable stent implantation with balloon angioplasty in patients with coronary artery disease</article-title>
          <source>N Engl J Med</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>489</fpage>
          <lpage>95</lpage>
          <volume>331</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Serruys</surname>
              <given-names>PW</given-names>
            </name>
            <name>
              <surname>Jaegere</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Kiemeneij</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>et</surname>
              <given-names>al</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Ruygrok PN, Serruys PW. Intracoronary stenting.    From concept to custom<italic>. </italic>Circulation 1996; 94: 882-90. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>From concept to custom</article-title>
          <source>Circulation</source>
          <date>
            <year>1996</year>
          </date>
          <fpage>882</fpage>
          <lpage>90</lpage>
          <volume>94</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Ruygrok</surname>
              <given-names>PN</given-names>
            </name>
            <name>
              <surname>Serruys</surname>
              <given-names>PW.</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. Till FV, Aliabadi D, Kinn JW, et al. Real    life stenting: a comparison of target vessel revascularization in Benestent-Stress    lesions to non Benestent-Stress lesions. [Abstract] Circulation 1996; 94(Suppl.    I): I-332. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Real life stenting: a comparison of target vessel revascularization in Benestent-Stress lesions to non Benestent-Stress lesions</article-title>
          <source>Circulation</source>
          <date>
            <year>1996</year>
          </date>
          <fpage>I</fpage>
          <lpage>332</lpage>
          <issue>Suppl. I</issue>
          <volume>94</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Till</surname>
              <given-names>FV</given-names>
            </name>
            <name>
              <surname>Aliabadi</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Kinn</surname>
              <given-names>JW</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Lowe HC, Oesterle SN, Khachigian LM. Coronary    in-stent restenosis: current status and future strategies. J Am Coll Cardiol    2002; 39: 183-93. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Coronary in-stent restenosis: current status and future strategies</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>183</fpage>
          <lpage>93</lpage>
          <volume>39</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Lowe</surname>
              <given-names>HC</given-names>
            </name>
            <name>
              <surname>Oesterle</surname>
              <given-names>SN</given-names>
            </name>
            <name>
              <surname>Khachigian</surname>
              <given-names>LM</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. Dussaillant GR, Mintz GS, Pichard AD, et al.    Small stent size and intimal hyperplasia contribute to restenosis: a volumetric    intravascular ultrasound analysis. J Am Coll Cardiol 1995; 26: 720-4. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Small stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>720</fpage>
          <lpage>4</lpage>
          <volume>26</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Dussaillant</surname>
              <given-names>GR</given-names>
            </name>
            <name>
              <surname>Mintz</surname>
              <given-names>GS</given-names>
            </name>
            <name>
              <surname>Pichard</surname>
              <given-names>AD</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B6">
        <mixed-citation>6. Hoffmann R, Mintz GS, Dussaillant GR, et al.    Patterns and mechanisms of in-stent restenosis: a serial intravascular ultrasound    study. Circulation 1996; 94: 1247-54. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Patterns and mechanisms of in-stent restenosis: a serial intravascular ultrasound study</article-title>
          <source>Circulation</source>
          <date>
            <year>1996</year>
          </date>
          <fpage>1247</fpage>
          <lpage>54</lpage>
          <volume>94</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Hoffmann</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Mintz</surname>
              <given-names>GS</given-names>
            </name>
            <name>
              <surname>Dussaillant</surname>
              <given-names>GR</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B7">
        <mixed-citation>7. Inoue T, Sohma R, Miyazaki T, et al. Comparison    of activation process of platelets and neutrophils after coronary stent implantation    versus balloon angioplasty for stable angina pectoris. Am J Cardiol 2000; 86:    1057-62. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Comparison of activation process of platelets and neutrophils after coronary stent implantation versus balloon angioplasty for stable angina pectoris</article-title>
          <source>Am J Cardiol</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>1057</fpage>
          <lpage>62</lpage>
          <volume>86</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Inoue</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Sohma</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Miyazaki</surname>
              <given-names>T</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B8">
        <mixed-citation>8. Bolz A, Amon M, Osbek C, et al. Coating of    cardiovascular stents with a semi-conductor to improve their hemocompatibility.    Tex Heart Inst J 1996; 23: 162-6. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Coating of cardiovascular stents with a semi-conductor to improve their hemocompatibility</article-title>
          <source>Tex Heart Inst J</source>
          <date>
            <year>1996</year>
          </date>
          <fpage>162</fpage>
          <lpage>6</lpage>
          <volume>23</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Bolz</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Amon</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Osbek</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B9">
        <mixed-citation>9. Monnink SHJ, Van Boven AJ, Peels HJ, et al.    Silicon-carbide coated coronary stents have low platelet and leukocyte adhesion    during platelet activation. J Investig Med 1999; 47: 304-10. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Silicon-carbide coated coronary stents have low platelet and leukocyte adhesion during platelet activation</article-title>
          <source>J Investig Med</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>304</fpage>
          <lpage>10</lpage>
          <volume>47</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Monnink</surname>
              <given-names>SHJ</given-names>
            </name>
            <name>
              <surname>Van</surname>
              <given-names>Boven AJ</given-names>
            </name>
            <name>
              <surname>Peels</surname>
              <given-names>HJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B10">
        <mixed-citation>10. Armitage P, Berry G. The planning of statistical    investigations. In: Armitage P, Berry G, ed. Statistical Methods in Medical    Research<bold>. </bold>Oxford: Blackwell, 1994: 175-206. </mixed-citation>
        <element-citation publication-type="book">
          <source>Statistical Methods in Medical Research</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>175</fpage>
          <lpage>206</lpage>
          <person-group person-group-type="author">
            <name>
              <surname>Armitage</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Berry</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Armitage</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Berry</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B11">
        <mixed-citation>11. Serruys PW, Unger F, Sousa JE, et al. Comparison    of coronary artery bypass surgery and stenting for the treatment of multivessel    disease. N Engl J Med 2001; 344: 1117-24. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Comparison of coronary artery bypass surgery and stenting for the treatment of multivessel disease</article-title>
          <source>N Engl J Med</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>1117</fpage>
          <lpage>24</lpage>
          <volume>344</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Serruys</surname>
              <given-names>PW</given-names>
            </name>
            <name>
              <surname>Unger</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Sousa</surname>
              <given-names>JE</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B12">
        <mixed-citation>12. Lincoff AM, Topol EJ, Ellis SG. Local drug    delivery for the prevention of restenosis. Fact, fancy and future. Circulation    1994; 90: 2070-84. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Local drug delivery for the prevention of restenosis: Fact, fancy and future</article-title>
          <source>Circulation</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>2070</fpage>
          <lpage>84</lpage>
          <volume>90</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Lincoff</surname>
              <given-names>AM</given-names>
            </name>
            <name>
              <surname>Topol</surname>
              <given-names>EJ</given-names>
            </name>
            <name>
              <surname>Ellis</surname>
              <given-names>SG.</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B13">
        <mixed-citation>13. Chandrasekar B, Tanguay JF. Platelets and    restenosis. J Am Coll Cardiol 2000; 35: 555-62. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Platelets and restenosis</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>555</fpage>
          <lpage>62</lpage>
          <volume>35</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Chandrasekar</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Tanguay</surname>
              <given-names>JF</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B14">
        <mixed-citation>14. Schwartz RS, Holmes DR, Topol EJ. The restenosis    paradigm revisited: an alternative proposal for cellular mechanisms. J Am Coll    Cardiol 1992; 20: 1284-93. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>The restenosis paradigm revisited: an alternative proposal for cellular mechanisms</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>1992</year>
          </date>
          <fpage>1284</fpage>
          <lpage>93</lpage>
          <volume>20</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Schwartz</surname>
              <given-names>RS</given-names>
            </name>
            <name>
              <surname>Holmes</surname>
              <given-names>DR</given-names>
            </name>
            <name>
              <surname>Topol</surname>
              <given-names>EJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B15">
        <mixed-citation>15. Hoffmann R, Mintz GS. Coronary in-stent restenosis     predictors, treatment and prevention. Eur Heart J 2000; 21: 1739-49.    </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Coronary in-stent restenosis - predictors, treatment and prevention</article-title>
          <source>Eur Heart J</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>1739</fpage>
          <lpage>49</lpage>
          <volume>21</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Hoffmann</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Mintz</surname>
              <given-names>GS</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B16">
        <mixed-citation>16. Babapulle MN, Eisenberg MJ. Coated stents    for the prevention of restenosis: part II. Circulation 2002; 106: 2859-66. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Coated stents for the prevention of restenosis: part II</article-title>
          <source>Circulation</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>2859</fpage>
          <lpage>66</lpage>
          <volume>106</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Babapulle</surname>
              <given-names>MN</given-names>
            </name>
            <name>
              <surname>Eisenberg</surname>
              <given-names>MJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B17">
        <mixed-citation>17. Heublein B, Ozbek C, Pethig K. Silicon carbide-coated    stents: clinical experience in coronary lesions with increased thrombotic risk.    J Endovasc Surg 1998; 51: 32-6. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Silicon carbide-coated stents: clinical experience in coronary lesions with increased thrombotic risk</article-title>
          <source>J Endovasc Surg</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>32</fpage>
          <lpage>6</lpage>
          <volume>51</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Heublein</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Ozbek</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Pethig</surname>
              <given-names>K</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B18">
        <mixed-citation>18. Hanekamp CEE, Bonnier HJRM, Michels RH, et    al. Initial results and long-term clinical follow-up of an amorphous hydrogenated    silicon-carbide coated stent in daily practice. Int J Cardiovasc Interv 1998;    1: 81-6. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Initial results and long-term clinical follow-up of an amorphous hydrogenated silicon-carbide coated stent in daily practice</article-title>
          <source>Int J Cardiovasc Interv</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>81</fpage>
          <lpage>6</lpage>
          <volume>1</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Hanekamp</surname>
              <given-names>CEE</given-names>
            </name>
            <name>
              <surname>Bonnier</surname>
              <given-names>HJRM</given-names>
            </name>
            <name>
              <surname>Michels</surname>
              <given-names>RH</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B19">
        <mixed-citation>19. Heublein B, Pethig K, Elsayed AM. Silicon    carbide coating: a semiconducting hybrid design of coronary stents. A feasibility    study. J Invas Cardiol 1998; 10: 255-62. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>A feasibility study</article-title>
          <source>J Invas Cardiol</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>255</fpage>
          <lpage>62</lpage>
          <volume>10</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Heublein</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Pethig</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Elsayed</surname>
              <given-names>AM.</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B20">
        <mixed-citation>20. Hamm CW, Hugenholtz PG. Silicon carbide coated    stents in patients with acute coronary syndrome (Trust study). Catheter Cardiovasc    Interv 2003; 60: 375-81. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Silicon carbide coated stents in patients with acute coronary syndrome (Trust study)</article-title>
          <source>Catheter Cardiovasc Interv</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>375</fpage>
          <lpage>81</lpage>
          <volume>60</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Hamm</surname>
              <given-names>CW</given-names>
            </name>
            <name>
              <surname>Hugenholtz</surname>
              <given-names>PG</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B21">
        <mixed-citation>21. Morice MC, Serruys PW, Sousa JE, et al. A    randomized comparison of a sirolimus-eluting stent with a standard stent for    coronary revascularization. N Engl J Med 2002; 346: 1773-80. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization</article-title>
          <source>N Engl J Med</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>1773</fpage>
          <lpage>80</lpage>
          <volume>346</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Morice</surname>
              <given-names>MC</given-names>
            </name>
            <name>
              <surname>Serruys</surname>
              <given-names>PW</given-names>
            </name>
            <name>
              <surname>Sousa</surname>
              <given-names>JE</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B22">
        <mixed-citation>22. Elezi S, Kastrati A, Neumann FJ, et al. Vessel    size and long-term outcome after coronary stent placement. Circulation 1998;    98: 1875-80. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Vessel size and long-term outcome after coronary stent placement</article-title>
          <source>Circulation</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>1875</fpage>
          <lpage>80</lpage>
          <volume>98</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Elezi</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Kastrati</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Neumann</surname>
              <given-names>FJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B23">
        <mixed-citation>23. Pache J, Kastrati A, Mehilli J, et al. Intracoronary    stenting and angiographic results: strut thickness effect on restenosis outcome    (Isar-Stereo-2) trial. J Am Coll Cardiol 2003; 41: 1283-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (Isar-Stereo-2) trial</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>1283</fpage>
          <lpage>8</lpage>
          <volume>41</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Pache</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Kastrati</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Mehilli</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Articles</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Randomized intravascular ultrasound comparison between endoprostheses with and without amorphous silicon-carbide</article-title>
      </title-group>
      <abstract xml:lang="en">
        <p>OBJECTIVE: In-stent restenosis remains a major limitation following coronary stent implantation. Amorphous silicon-carbide (a-SiC) coating has been shown to improve stent biocompatibility, therefore, reducing local inflammation and thrombus generation. Due to the latter, a-SiC coating might have an impact on the prevention of neointimal hyperplasia (NIH) and restenosis. METHODS: This prospective, randomized, open-label trial compared a-SiC-coated (group A) versus uncoated (group B) stent implantation in de novo lesions. We included 100 patients (50 patients in each group) and the primary end-point was in-stent volume of NIH measured by intravascular ultrasound. RESULTS: All patients underwent successful stent deployment. Although absolute NIH volume was greater in A (51.2 mm&#179; SD 18.8 mm&#179; versus 41.9 mm&#179; SD 16.4 mm&#179;; P = 0.014), relative (divided per mm of stent length) NIH volume was similar (2.9 mm&#179;/mm stent SD 1.0 mm&#179;/mm stent versus 2.5 mm&#179;/mm stent SD 0.9 mm&#179;/mm stent; P = 0.108). Late loss, restenosis, and major adverse cardiac events (MACE) were similar. CONCLUSION: A-SiC-coated stents did not reduce either NIH or MACE at long-term follow-up.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>restenosis</kwd>
        <kwd>coronary artery disease</kwd>
        <kwd>percutaneous coronary intervention</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>ORIGINAL ARTICLE</bold>
      </p>
      <p>Randomized intravascular ultrasound comparison between endoprostheses with and without amorphous silicon-carbide</p>
      <p>Luiz Fernando Leite Tanajura; J. Eduardo M. R. Sousa; Amanda G. M. R. Sousa; Alexandre Abizaid; Jo&#227;o Eduardo T. Paula; Mariano Albertal; Fausto Feres; Luiz Alberto P. Mattos; Rodolfo Staico; Ibraim M.F. Pinto</p>
      <p> S&#227;o Paulo, SP - Brazil</p>
      <p>Instituto Dante Pazzanese de Cardiologia </p>
      <p>
        <xref ref-type="corresp" rid="end-body2">Correspondence</xref>
      </p>
      <p>
        <bold>ABSTRACT</bold>
      </p>
      <p><bold>OBJECTIVE: </bold>In-stent restenosis remains a major limitation following coronary stent implantation. Amorphous silicon-carbide (a-SiC) coating has been shown to improve stent biocompatibility, therefore, reducing local inflammation and thrombus generation. Due to the latter, a-SiC coating might have an impact on the prevention of neointimal hyperplasia (NIH) and restenosis.</p>
      <p><bold>METHODS:</bold> This prospective, randomized, open-label trial compared a-SiC-coated (group A) versus uncoated (group B) stent implantation in de novo lesions. We included 100 patients (50 patients in each group) and the primary end-point was in-stent volume of NIH measured by intravascular ultrasound.</p>
      <p><bold>RESULTS:</bold> All patients underwent successful stent deployment. Although absolute NIH volume was greater in A (51.2 mm<sup>3 </sup>SD 18.8 mm<sup>3</sup> versus 41.9 mm<sup>3 </sup>SD 16.4 mm<sup>3</sup>; P = 0.014), relative (divided per mm of stent length) NIH volume was similar (2.9 mm<sup>3</sup>/mm stent SD 1.0 mm<sup>3</sup>/mm stent versus 2.5 mm<sup>3</sup>/mm stent SD 0.9 mm<sup>3</sup>/mm stent; P = 0.108). Late loss, restenosis, and major adverse cardiac events (MACE) were similar.</p>
      <p><bold>CONCLUSION: </bold> A-SiC-coated stents did not reduce either NIH or MACE at long-term follow-up. </p>
      <p><bold>Keywords:</bold> restenosis, coronary artery disease, percutaneous coronary intervention</p>
      <p> The superiority of coronary stent implantation over percutaneous transluminal balloon angioplasty in virtually all lesion subsets has led to the wide use of stents for the percutaneous treatment of coronary lesions <sup>1,2</sup>. However, in-stent restenosis remains as a major limitation <sup>3,4</sup>. </p>
      <p>Recent data suggest that neointimal proliferation, the cornerstone of in-stent restenosis <sup>5,6</sup>, is related to the presence of thrombus and degree of inflammation at the stent site<sup>7</sup>. A potential approach for the prevention of neointimal proliferation is the use of amorphous silicon-carbide (a-SiC), an inactive substance known to have antithrombotic and anti-inflammatory properties <sup>8,9</sup>. By coating stents with a-SiC, hemo- and biocompatibility of stent prostheses is enhanced, potentially reducing neointimal proliferation. </p>
      <p>Therefore, the purpose of the CERAMIC trial (randomized intravascular ultrasound Comparison between EndopRostheses with and without AMorphous sIlicon-Carbide for the prevention of coronary restenosis) was to determine whether a-SiC-coated stents prevent intrastent neointimal proliferation in humans. </p>
      <p>
        <bold>Methods</bold>
      </p>
      <p>The study was performed according to the Declaration of Helsinki. The study protocol was approved by the institutional ethical committee. Informed consent was obtained from each patient before enrollment. </p>
      <p>The criteria for enrollment included the following: a single symptomatic or ischemia-driven <italic>de novo</italic> coronary lesion suitable for stent implantation in a native coronary artery. Exclusion criteria included: 1) acute coronary event within 72 hours prior to the intervention, 2) lesion located in the left main coronary artery, 3) ostial, bifurcated, or totally occluded lesions, 4) target artery &lt; 3.0 mm or &gt; 4.0 mm in size or &gt; 15 mm in length. </p>
      <p>Patients were randomized to either a-SiC-coated Teneo (Biotronik, Germany, group A) or bare Bx Velocity (Cordis, United States of America, group B) stent implantation. Teneo is a 316L stainless steel balloon-expandable tubular-slotted stent with a strut thickness of 0.08 mm and coated with a-SiC. The coating process with a-SiC is carried out by a plasma-enhanced chemical vapor deposition technique, which results in an a-SiC coating thickness of 0.08 mg. All Teneo stents were 15 or 20 mm in length and 3.0 or 3.5 mm in diameter, whereas all Bx Velocity stents used were 13 or 18 mm in length and 3.0 or 3.5 mm in diameter. </p>
      <p>Stent implantation was performed using the conventional technique after balloon predilatation. Postdilatation was performed if necessary. Periprocedural intravenous heparin was given to maintain an activated clotting time &gt;250 seconds, and all patients received aspirin (200 mg once daily) and clopidogrel (300 mg loading dose followed by 75 mg once daily) or ticlopidine (250 mg twice daily) for one month. </p>
      <p>Clinical information was collected 30 days, 3 months, and 6 months after the procedure. Angiographic and intravascular ultrasound (IVUS) follow-ups were performed at the 6-month visit. Major adverse cardiac events (MACE) were defined as death, myocardial infarction, target vessel repeat percutaneous coronary intervention, or coronary artery bypass grafting. </p>
      <p>Pre- and postprocedural as well as follow-up angiographic data were analyzed offline using the Cardiovascular Angiographic Analysis System (CASS II, Pie Medical Imaging, Maastricht, The Netherlands) as described elsewhere. Following an intracoronary nitrate bolus, the angiographic view with the worst luminal diameter was selected for the analysis. IVUS images were acquired using motorized pull-back at a constant speed of 0.5 mm/s. Three segments were selected for angiographic and volumetric IVUS analysis: the stented segment and 2 edge segments that were axially 5 mm proximal and distal to the stent margins. IVUS volumetric analysis was performed with commercially available software (Echoplaque, Indec Systems, USA) </p>
      <p>In an attempt to correct for occasional differences in stent length deployed between groups, not only absolute but also relative (per millimeter stent length) neointimal hyperplasia (NIH) volume was calculated. Volume obstruction was defined as the ratio of the volume of NIH to the volume of the stent, multiplied by 100. </p>
      <p>The primary end-point was neointimal proliferation assessed by IVUS at 6-month follow-up catheterization. Secondary endpoints were 1) binary restenosis rate; 2) minimal luminal diameter (MLD) at 6-month follow-up angiography and late loss; 3) MACE at 6-month follow-up. </p>
      <p>The size of the patient group required to test the hypothesis was calculated by the method already described by Armitage et al <sup>10</sup>. The expected NIH volume as measured by IVUS following Bx Velocity is 40.0 mm<sup>3</sup>, with a standard deviation (SD) of 20.0 mm<sup>3</sup>, a value that was determined by previous observations at six-month follow-up of patients who had received Bx-Velocity<sup>&#174;</sup> stents. To detect a 30% reduction in NIH volume with a-SiC-coated stent treatment with 80% power at a 2-sided type I error rate (alpha) of 0.05, it was calculated that at least 34 patients in each group were necessary. </p>
      <p>All statistical analyses were undertaken using SPSS (SPSS UK Ltd, Surrey, UK). Continuous variables are expressed as mean (SD) and were compared by the unpaired Student <italic>t </italic>test. Categorical variables were represented by percentages and absolute frequencies and compared by chi-square test with Fisher correction. P-value &lt; 0.05 was considered statistically significant. Analysis was performed according to the intention to treat. </p>
      <p>
        <bold>Results</bold>
      </p>
      <p>As shown in <xref ref-type="table" rid="tab01-body2">table I</xref>, baseline clinical and angiographic characteristics were similar between groups. </p>
      <table-wrap id="tab01-body2">
        <graphic xlink:href="1678-4170-abc-83-spe-0059-00011-gt01-en.jpg"/></table-wrap>
      <p>All patients underwent successful stent implantation. No significant differences in postprocedural MLD or acute gain were found between groups. Stent size most commonly deployed was 3.5 mm (56% and 54%, for group A and B, respectively). Stent length was similar between groups (17.7 mm SD 4.0 mm versus 16.7 mm SD 4.3 mm; P = 0.231). Only 2% of the patients from the coated group, and 4% of the controls required additional stent implantation. No major in-hospital complications occurred. </p>
      <p>No events occurred at 30 days. All patients underwent clinical follow-up at 6 months after catheterization. MACE rates were not significantly different between groups (20% versus 16%; for group A and B, respectively, P = 0.795). Target lesion revascularization was also similar between groups (14% for both groups). In group A, one patient suffered sudden death 3 months following stenting, whereas one in group A and 2 patients in group B suffered an acute myocardial infarction. Repeat target vessel revascularization was necessary in 16% and 14% of the patients (group A and B, respectively; P = 1.000). Only one patient (group A) required surgical revascularization due to a long proliferative in-stent restenosis of the left descending coronary artery. </p>
      <p>At 6-month follow-up, 94% (n=47) of the cases in each group underwent angiographic assessment. No significant differences existed in in-stent restenosis rates [9 (19.1%) versus 8 (17.0%), for group A and B, respectively; P = 1.000]. In addition, the restenosis pattern was also similar: focal (44.4% group A versus 50.0% in group B; P = 1.000) and diffuse (56.6% group A versus 50.0% in group B; P = 1.000). </p>
      <p>As <xref ref-type="table" rid="tab02-body2">table II</xref> shows, the in-stent follow-up MLD, late loss, loss index, net gain as well as follow-up MLD, and late loss values at both the proximal and the distal edges were not different between groups. </p>
      <table-wrap id="tab02-body2">
        <graphic xlink:href="1678-4170-abc-83-spe-0059-00011-gt02-en.jpg"/></table-wrap>
      <p>A total of 92% (n=46 and 45 for group A and B, respectively) of the patients in each group underwent IVUS assessment at 6-month follow-up. </p>
      <p>Although absolute NIH volume was significantly higher in the coated group (51.2 mm<sup>3 </sup>SD 18.8 mm<sup>3</sup> versus 41.9 mm<sup>3 </sup>SD 16.4 mm<sup>3</sup>; P = 0.014), no differences existed in relative NIH volume between the groups (2.9 mm<sup>3</sup>/mm stent SD 1.0 mm<sup>3</sup>/mm stent versus 2.5 mm<sup>3</sup>/mm stent SD 0.9 mm<sup>3</sup>/mm stent, for group A and B; P = 0.108). Volume obstruction was also similar between groups (36.4% SD 11.1% in group A versus 37.9% SD 10.9% in group B; P = 0.505). Moreover, proximal and distal edge volumes were not different between groups (<xref ref-type="table" rid="tab03-body2">tab. III</xref>). Late incomplete apposition was not observed in our study. </p>
      <table-wrap id="tab03-body2">
        <graphic xlink:href="1678-4170-abc-83-spe-0059-00011-gt03-en.jpg"/></table-wrap>
      <p>
        <bold>Discussion</bold>
      </p>
      <p>The occurrence of in-stent restenosis limits long-term results following percutaneous interventions <sup>3,4,11</sup>. In the ARTS trial,<sup>11</sup> which compared surgical versus percutaneous revascularization in a multivessel diseased population, no significant differences in death, stroke, or myocardial infarction were found at long-term follow-up. However, one-year repeat revascularization rates were much higher in the nonsurgical group (21% versus 4%; P &lt; 0.001), mostly due to in-stent restenosis. In addition, despite the economical advantage observed in that study by selecting a percutaneous approach, this advantage narrowed down considerably at long-term follow-up when compared with that in the in-hospital phase. </p>
      <p>Recent data suggest that neointimal proliferation is strongly related to the degree of inflammation and thrombus generated at the stent site <sup>12,13</sup>. In a clinical study utilizing the immunofluorescence technique <sup>9</sup>, local coronary artery wall changes were evaluated following balloon and stent implantation. In that study, late loss and restenosis rates were associated with thrombus formation and inflammation, only after stent implantation. In addition, several studies have reported that organized thrombus serves as a nidus for cytokine and growth factor release, which contribute to the process of neointimal formation <sup>12-14</sup>. </p>
      <p> So far, the use systemic antithrombotic or antiproliferative drugs has not consistently been shown to be efficacious in preventing neointimal proliferation <sup>15,16</sup>. Due to the latter, a new alternative therapeutic approach has emerged, the utilization of inert substances like a-SiC, an amorphous ceramic semiconductor material as stent coating, in an attempt to reduce the stent metallic thrombogenic predisposition <sup>16</sup>. This material prevents electron transfer usually taking place from the stainless steel to circulating peptides, especially fibrinogen <sup>8,9</sup>. When electron transfer occurs, fibrinogen changes its tertiary structure, which accelerates thrombus formation. Indeed, in vitro data have confirmed this hypothesis <sup>9</sup>. Moreover, immunofluorescence studies have also established its anti-inflammatory potential. Thus, by improving stent bio- and hemocompatibility, a-SiC coating could interfere with the organic reaction cascade that leads to NIH <sup>8,9,16</sup>. In the present study, the use of a-SiC-coated stents did not reduce either neointimal growth or revascularization rates at 6-month follow-up. In addition, IVUS analysis at the edges was also similar between groups. Up until now, scant data were available regarding a-SiC-coated stents. Although single center experience with a-SiC-coated stents has been reported, the lack of angiographic follow-up in those reports precludes any definitive conclusion <sup>16-19</sup>. In the TRUST study <sup>20</sup>, patients with unstable angina were randomized to a-SiC-coated or uncoated stent implantation, showing a reduction in target vessel revascularization at 6-month follow-up only in patients with unstable angina class IIIB (4.7% versus 15.3%). In our study, where the predominant clinical presentation was stable angina, the latter results were not reproduced. </p>
      <p>Regarding the control group, late loss (about 1.0 mm) and NIH (about 40.0 mm<sup>3</sup>) values were similar to those of the RAVEL bare stent group <sup>21</sup>. However, higher binary restenosis (26.6% versus 17.0%) and target-vessel revascularization (22.8% versus 14.0%) rates were found in the RAVEL control group when compared with ours. The latter might be due to a greater proportion of patients with diabetes (22.0% versus 14.0%) and lower preprocedural reference diameter values (2.6mm versus 2.8 mm) in RAVEL, which increase the risk for development of in-stent restenosis <sup>15,22</sup>. </p>
      <p>Another significant difference between the 2 groups was the degree of strut thickness, which is higher in the Bx Velocity<sup>&#174;</sup> group. A recent study <sup>23</sup> comparing stents with different strut thicknesses showed that higher strut thickness, using as a model the Bx Velocity<sup>&#174;</sup> stent, was associated with greater restenosis and revascularization rates when compared with thinner strut stents. The latter might be due to greater endothelial damage. </p>
      <p>Limitations - As mentioned above, a major difference between the 2 stent groups besides the a-SiC coating was the strut thickness. Nevertheless, in spite of the latter, no differences in NIH occurred. In addition, because patients with complex lesions were excluded, no conclusions could be drawn regarding the performance of the a-SiC-coated stent in that patient subgroup. Although MACE rates were similar between the 2 groups, we can not conclude that these 2 stents are clinically similar due to the size of the study population. </p>
      <p>In conclusion, the results of the CERAMIC trial indicate that the a-SiC-coated stent in this broad, comprehensive population was not superior to the bare stent as far as the long-term clinical, angiographic, and IVUS findings are concerned.</p>
      <p>
        <bold>References</bold>
      </p>
      <p>
        <fn id="end-body2" fn-type="corresp">
          <p>Correspondence to</p>
          <p> Luiz Fernando Leite Tanajura </p>
          <p> Rua Caiubi, 324/71</p>
          <p> Cep 05010-000 </p>
          <p> S&#227;o Paulo - SP - Brazil </p>
          <p> E-mail: </p>
          <p>
            <email xlink:href="lfleite@cardiol.br">lfleite@cardiol.br</email>
          </p>
        </fn>
      </p>
      <p>Received for publication: 06/24/04</p>
      <p> Accepted for publication: 09/15/04</p>
    </body>
  </sub-article>
</article>