<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">M3NWBh9rbvH7DpmCZ75m4PM</article-id>
      <article-id pub-id-type="other">00006</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2004001300006</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(04)08300106</article-id>
      <article-id pub-id-type="doi">10.1590/S0066-782X2004001300006</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigos Originais</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Braquiterapia intracoronariana. Tratamento da reestenose intra-stent com o sistema Beta-Cath: experi&#234;ncia inicial na Am&#233;rica Latina</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Mu&#241;oz</surname>
            <given-names>Juan Simon</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Feres</surname>
            <given-names>Fausto</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Abizaid</surname>
            <given-names>Alexandre C.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Mattos</surname>
            <given-names>Luiz A.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Staico</surname>
            <given-names>Rodolfo</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Centemero</surname>
            <given-names>Marinella</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Tanajura</surname>
            <given-names>Luiz F.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Pinto</surname>
            <given-names>Ibraim</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Sousa</surname>
            <given-names>Amanda G.M.R.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Sousa</surname>
            <given-names>J. Eduardo</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <addr-line>
          <named-content content-type="city">S&#227;o Paulo</named-content>
          <named-content content-type="state">S&#227;o Paulo</named-content>
        </addr-line>
        <institution content-type="orgname">Instituto Dante Pazzanese de Cardiologia</institution>
        <country country="BR">Brazil</country>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>07</month>
        <year>2004</year>
      </pub-date>
      <volume>83</volume>
      <issue>1</issue>
      <fpage>57</fpage>
      <lpage>62</lpage>
      <history>
        <date date-type="accepted">
          <day>06</day>
          <month>07</month>
          <year>2003</year>
        </date>
        <date date-type="received">
          <day>16</day>
          <month>04</month>
          <year>2003</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <abstract>
        <p>OBJETIVO: Avaliar a seguran&#231;a e efic&#225;cia da braquiterapia intracoronariana usando o sistema Beta-CathTM na preven&#231;&#227;o da recorr&#234;ncia de restenose intra-stent (RIS), por meio da an&#225;lise dos resultados cl&#237;nicos, angiogr&#225;ficos e pelo ultra-som intracoronariano (USIC). M&#201;TODO: Foram submetidos &#224; angioplastia com cateter-bal&#227;o, seguida de beta-radia&#231;&#227;o intracoronariana com o sistema Beta-CathTM (90Sr/Y) 30 pacientes com RIS em art&#233;rias coron&#225;rias nativas e, posteriormente, avaliados. RESULTADOS: Inclu&#237;ram-se les&#245;es reesten&#243;ticas complexas (77% do tipo difuso-proliferativo) com extens&#227;o elevada (18,66&#177;4,15 mm). O sucesso da braquiterapia foi de 100%. A dose m&#233;dia utilizada foi de 20,7&#177;2,3 Gy, liberada em um per&#237;odo m&#233;dio de 3,8&#177;2,1 min. No seguimento tardio, o di&#226;metro luminal m&#237;nimo (DLM) intra-stent diminuiu discretamente (1,98&#177;0,30mm para 1,84&#177;0,39 aos 6 meses, p=0,13), com uma perda tardia de 0,14&#177;0,18 mm. O DLM intra-segmentar foi significativamente menor do que o intra-stent (1,55&#177;0,40mm vs.1,84&#177;0,39mm, p=0,008), associando-se &#224; perda tardia (0,40&#177;0,29mm vs. 0,14&#177;0,18mm; p=0,0001). No USIC, observou-se discreto incremento do tecido neointimal em 6,8&#177;14,3 mm&#179; aos 6 meses (p=0,19) e a percentagem de obstru&#231;&#227;o volum&#233;trica aumentou em 4,7&#177;7,5%. A reestenose bin&#225;ria e a revasculariza&#231;&#227;o do vaso-alvo recorreram em 17% dos casos; houve 1 caso (3%) de oclus&#227;o tardia, associada a infarto do mioc&#225;rdio. A sobrevida livre de eventos foi de 80%. CONCLUS&#195;O: O manejo da reestenose intra-stent com a beta-radia&#231;&#227;o intracoronariana mostrou-se procedimento seguro e eficaz, com alta taxa de sucesso imediato, representando uma op&#231;&#227;o terap&#234;utica para a inibi&#231;&#227;o da hiperplasia neointimal.</p>
      </abstract>
      <kwd-group xml:lang="pt" kwd-group-type="author-generated">
        <kwd>reestenose intra-stent</kwd>
        <kwd>braquiterapia</kwd>
        <kwd>sistema Beta-CathTM</kwd>
      </kwd-group>
      <pub-date publication-format="electronic" date-type="pub">
        <day>17</day>
        <month>08</month>
        <year>2004</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>
      <bold>ARTIGO ORIGINAL</bold>
    </p>
    <p>Braquiterapia intracoronariana. Tratamento da reestenose intra-<italic><bold>stent</bold></italic> com o sistema Beta-Cath. experi&#234;ncia inicial na Am&#233;rica Latina</p>
    <p>
      <bold>Juan Simon Mu&#241;oz; Fausto Feres; Alexandre C. Abizaid; Luiz A. Mattos; Rodolfo Staico; Marinella Centemero; Luiz F. Tanajura; Ibraim Pinto; Amanda G.M.R. Sousa; J. Eduardo Sousa</bold>
    </p>
    <p>Instituto Dante Pazzanese de Cardiologia </p>
    <p>S&#227;o Paulo, SP</p>
    <p>
      <xref ref-type="corresp" rid="back10">Endere&#231;o para correspond&#234;ncia</xref>
    </p>
    <p>
      <bold>RESUMO</bold>
    </p>
    <p><bold>OBJETIVO:</bold> Avaliar a seguran&#231;a e efic&#225;cia da braquiterapia intracoronariana usando o sistema Beta-Cath<sup>TM</sup> na preven&#231;&#227;o da recorr&#234;ncia de restenose intra-stent (RIS), por meio da an&#225;lise dos resultados cl&#237;nicos, angiogr&#225;ficos e pelo ultra-som intracoronariano (USIC). </p>
    <p><bold> M&#201;TODO:</bold> Foram submetidos &#224; angioplastia com cateter-bal&#227;o, seguida de beta-radia&#231;&#227;o intracoronariana com o sistema Beta-Cath<sup>TM</sup> (<sup>90</sup>Sr/Y) 30 pacientes com RIS em art&#233;rias coron&#225;rias nativas e, posteriormente, avaliados. </p>
    <p><bold> RESULTADOS:</bold> Inclu&#237;ram-se les&#245;es reesten&#243;ticas complexas (77% do tipo difuso-proliferativo) com extens&#227;o elevada (18,66&#177;4,15 mm). O sucesso da braquiterapia foi de 100%. A dose m&#233;dia utilizada foi de 20,7&#177;2,3 Gy, liberada em um per&#237;odo m&#233;dio de 3,8&#177;2,1 min. No seguimento tardio, o di&#226;metro luminal m&#237;nimo (DLM) intra-stent diminuiu discretamente (1,98&#177;0,30mm para 1,84&#177;0,39 aos 6 meses, p=0,13), com uma perda tardia de 0,14&#177;0,18 mm. O DLM intra-segmentar foi significativamente menor do que o intra-stent (1,55&#177;0,40mm vs.1,84&#177;0,39mm, p=0,008), associando-se &#224; perda tardia (0,40&#177;0,29mm vs. 0,14&#177;0,18mm; p=0,0001). No USIC, observou-se discreto incremento do tecido neointimal em 6,8&#177;14,3 mm<sup>3</sup> aos 6 meses (p=0,19) e a percentagem de obstru&#231;&#227;o volum&#233;trica aumentou em 4,7&#177;7,5%. A reestenose bin&#225;ria e a revasculariza&#231;&#227;o do vaso-alvo recorreram em 17% dos casos; houve 1 caso (3%) de oclus&#227;o tardia, associada a infarto do mioc&#225;rdio. A sobrevida livre de eventos foi de 80%. </p>
    <p><bold> CONCLUS&#195;O:</bold> O manejo da reestenose intra-stent com a beta-radia&#231;&#227;o intracoronariana mostrou-se procedimento seguro e eficaz, com alta taxa de sucesso imediato, representando uma op&#231;&#227;o terap&#234;utica para a inibi&#231;&#227;o da hiperplasia neointimal.</p>
    <p><bold>Palavra-chave: </bold>reestenose intra-stent, braquiterapia, sistema Beta-Cath<sup>TM</sup></p>
    <p>Embora o implante de <italic>stent</italic> coronariano tenha-se tornado o procedimento percut&#226;neo predominante de revasculariza&#231;&#227;o mioc&#225;rdica nas &#250;ltimas d&#233;cadas, a presen&#231;a de reestenose persiste como sua maior limita&#231;&#227;o e sua resolu&#231;&#227;o constitui um dos maiores desafios da cardiologia intervencionista contempor&#226;nea <sup>1</sup>. A recorr&#234;ncia de estenose ap&#243;s implante de <italic>stent</italic> coronariano varia entre 7 a 37% dos casos, dependendo das caracter&#237;sticas cl&#237;nicas do paciente, morfol&#243;gicas da les&#227;o e t&#233;cnicas do procedimento<sup>2-4</sup>. A reestenose intra-<italic>stent</italic> &#233; causada, principalmente, pela prolifera&#231;&#227;o do tecido neo-intimal distribu&#237;do de forma focal ou difusa<sup>4,5</sup>. A incid&#234;ncia de eventos card&#237;acos maiores, em especial revasculariza&#231;&#227;o do vaso alvo, ap&#243;s tratamento convencional da reestenose intra-<italic>stent</italic> &#233; elevada (30%-80%), independentemente da t&#233;cnica e do instrumental utilizado<sup>6-9</sup>.</p>
    <p>A braquiterapia &#233; um tratamento promisor para redu&#231;&#227;o de nova reestenose intra-<italic>stent</italic>, fundamentando-se no potencial de inibi&#231;&#227;o que a radia&#231;&#227;o exerce sobre a prolifera&#231;&#227;o das c&#233;lulas musculares lisas, principal constituinte do tecido neo-intimal<sup>10</sup>. Atua por meio de um is&#243;topo ativo, liberado para bloquear a fase mit&#243;tica do ciclo celular, causando uma dupla ruptura da cadeia do DNA da c&#233;lula muscular lisa<sup>11,12</sup>.</p>
    <p>Em estudos pr&#233;vios, a angioplastia com cateter bal&#227;o, seguida de radia&#231;&#227;o gama intracoronariana com ir&#237;dio-192<sup>9,13,14</sup> ou radia&#231;&#227;o beta-intracoronariana com estr&#244;ncio/ytrio 90 (Sr<sup>90</sup>/Y<sup>90</sup>)<sup>15</sup> relatou redu&#231;&#227;o da recorr&#234;ncia cl&#237;nica e angiogr&#225;fica nas recidivas difusas.</p>
    <p>Nosso objetivo foi avaliar a seguran&#231;a e viabilidade da braquiterapia intracoronariana ap&#243;s angioplastia com cateter bal&#227;o, usando o sistema Beta-Cath<sup>TM</sup> (Novoste Corp., Norcross, Georgia), bem como analisar os resultados cl&#237;nicos, angiogr&#225;ficos e do ultra-som intracoronariano imediatamente ap&#243;s a interven&#231;&#227;o e aos 180 dias do seguimento tardio.</p>
    <p>
      <bold>M&#233;todo</bold>
    </p>
    <p>De agosto/2001 a setembro/2002 foram inclu&#237;dos 30 pacientes com reestenose intra-<italic>stent</italic>, com antecedentes de implante de <italic>stent</italic> em art&#233;rias coron&#225;rias nativas, apresentando sintomas de angina ou isquemia silenciosa. Os crit&#233;rios angiogr&#225;ficos de inclus&#227;o foram: estenose de <underline>&gt;</underline> 50% no local da les&#227;o intra-<italic>stent</italic>, di&#226;metro de refer&#234;ncia entre 2,5mm e 4,0mm, extens&#227;o da les&#227;o <underline>&lt;</underline>25 mm e sucesso angiogr&#225;fico (estenose residual &lt;50%) imediatamente ap&#243;s angioplastia com bal&#227;o. Exclu&#237;ram-se os pacientes com disfun&#231;&#227;o ventricular esquerda importante (fra&#231;&#227;o de eje&#231;&#227;o &lt;30%), infarto agudo do miocardio recente (&lt;72h), evid&#234;ncia de trombos pela angiografia, presen&#231;a de m&#250;ltiplas les&#245;es no vaso alvo e radioterapia tor&#225;cica pr&#233;via. Durante o processo de inclus&#227;o, aqueles que n&#227;o preencheram o criterio angiogr&#225;fico de sucesso, n&#227;o receberam tratamento intracoronariano com radia&#231;&#227;o beta, por&#233;m n&#227;o foram exclu&#237;dos do registro. Todos os pacientes foram previamente informados das caracter&#237;sticas do procedimento e assinaram o termo de consentimento antes da inclus&#227;o.</p>
    <p>Todos receberam &#225;cido acetilsalic&#237;lico (325mg/dia) na v&#233;spera do procedimento. Administrou-se heparina intravenosa (100 UI/Kg) antes da interven&#231;&#227;o, para manter o tempo de coagula&#231;&#227;o ativado &gt; 300s. O regime terap&#234;utico p&#243;s-interven&#231;&#227;o consistiu de &#225;cido acetilsalic&#237;lico e tienopirid&#237;nicos (ticlopidina:500mg/dia ou clopidogrel:75mg/dia) por no m&#237;nimo 4 meses.</p>
    <p>Antes da interven&#231;&#227;o, documentamos, angiograficamente (<underline>&gt;</underline> 2 proje&#231;&#245;es), a extens&#227;o e a gravidade da les&#227;o, assim como o di&#226;metro luminal nos segmentos de refer&#234;ncia proximal e distal.</p>
    <p>O sistema Beta-Cath&#153; dispon&#237;vel no nosso servi&#231;o (Novoste Corp., Norcross, Georgia) consiste de uma serie de 16 sementes cil&#237;ndricas independentes e radiopacas, que cont&#233;m emissor beta puro estr&#244;ncio/ytrio 90 (<sup>90</sup>Sr/ <sup>90</sup>Y), limitados por 2 marcadores de ouro radiopacos, separados por 40mm, constituindo a extens&#227;o da fonte. O perfil do cateter &#233; de 5 <italic>French</italic> e o sistema da fonte n&#227;o &#233; centralizado. A libera&#231;&#227;o da dose ocorre a 2mm da fonte e &#233; adaptada ao di&#226;metro do vaso<sup>15</sup>.</p>
    <p>Ap&#243;s a angioplastia com cateter-bal&#227;o, realizamos ultra-som intracoronariano com administra&#231;&#227;o intracoronariana pr&#233;via de dinitrato de isosorbida (0,2 mg). Em seguida, avan&#231;amos o cateter liberador da fonte (<italic>beta-rail<sup>TM</sup></italic>) pr&#233;-montado sobre o fio-guia, colocado de forma "chis-distante", desde o centro do segmento que recebeu inj&#250;ria at&#233; 7mm al&#233;m de suas bordas, pela vis&#227;o angiogr&#225;fica dos marcadores da fonte (40mm). Ap&#243;s a retirada do fio-guia, a fonte &#233; transportada hidraulicamente at&#233; a por&#231;&#227;o distal do cateter liberador e seu posicionamento sempre documentado angiograficamente. Imediatamente ap&#243;s o t&#233;rmino do tempo de radia&#231;&#227;o calculado pelo oncologista (<xref ref-type="table" rid="t1">tab. I</xref>), a fonte &#233; retirada e o cateter liberador (<italic>beta-rail<sup>TM</sup></italic>) removido. Repetimos a avalia&#231;&#227;o angiogr&#225;fica nas mesmas proje&#231;&#245;es ortogonais e o ultra-som intracoronariano, finalizando assim a interven&#231;&#227;o.</p>
    <p content-type="asset">
      <table-wrap id="t1">
        <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gt01.jpg"/></table-wrap>
    </p>
    <p>O sucesso angiogr&#225;fico foi definido como a presen&#231;a de estenose residual &lt; 50%, sem intercorr&#234;ncia t&#233;cnica durante o processo de radia&#231;&#227;o. O sucesso da braquiterapia foi caracterizado pela libera&#231;&#227;o completa (&gt;90%) da dose de radia&#231;&#227;o estabelecida. O sucesso cl&#237;nico foi definido como a aus&#234;ncia de eventos card&#237;acos maiores (&#243;bito, infarto agudo do mioc&#225;rdio, documentado por crit&#233;rios eletrocardiogr&#225;ficos e enzim&#225;ticos [CK-MB &gt; 10-13 U/L ou &gt;5% da CK atividade e/ou eleva&#231;&#227;o de troponina T-I] e revasculariza&#231;&#227;o do vaso alvo) durante a hospitaliza&#231;&#227;o. Definiu-se sucesso do procedimento ap&#243;s braquiterapia como a associa&#231;&#227;o dos tr&#234;s anteriores.</p>
    <p>A an&#225;lise pela angiografia coronariana quantitativa foi realizada pelo m&#233;todo <italic>off-line</italic> usando o sistema QCA-CMS<sup>&#226;</sup> vers&#227;o 5.1 (MEDIS - <italic>Medical Imaging Sistems Inc. -</italic> AJ Leiden, <italic>The Netherlands</italic>), no laborat&#243;rio de dados e an&#225;lises hemodin&#226;micas de nossa Institui&#231;&#227;o. Todas as angiografias foram realizadas ap&#243;s administra&#231;&#227;o pr&#233;via de nitrato intracoronariano, calculando-se o di&#226;metro luminal m&#237;nimo, a percentagem de estenose (%DS) e o di&#226;metro de refer&#234;ncia. O ganho luminal agudo foi determinado como o di&#226;metro luminal m&#237;nimo ap&#243;s o tratamento &#150; di&#226;metro luminal m&#237;nimo inicial e a perda tardia foi calculada como o di&#226;metro luminal m&#237;nimo ap&#243;s tratamento &#150; di&#226;metro luminal m&#237;nimo tardio. Angiograficamente, a defini&#231;&#227;o de aneurisma se baseou na presen&#231;a de di&#226;metro luminal no segmento tratado 25% maior do que o di&#226;metro da luz nos segmentos de refer&#234;ncia adjacentes <sup>16</sup>.</p>
    <p>Ainda em rela&#231;&#227;o ao di&#226;metro luminal m&#237;nimo, aferiram-se: 1) di&#226;metro luminal m&#237;nimo intra-<italic>stent</italic>: compreendido pelo segmento alvo - margem distal e proximal da les&#227;o alvo; 2) di&#226;metro luminal m&#237;nimo intra-segmentar: compreendido pelo segmento que recebeu inj&#250;ria, localizado entre as marcas proximal e distal do bal&#227;o. Outros par&#226;metros avaliados foram o segmento irradiado, limitado pelas marcas proximal e distal do cateter de radia&#231;&#227;o e o segmento do vaso, limitado por duas refer&#234;ncias anat&#244;micas (ramos) nos quais inclu&#237;ram-se o segmento alvo, segmento que recebeu inj&#250;ria e o segmento irradiado. A aplica&#231;&#227;o desta classifica&#231;&#227;o tem sido comumente utilizada em outros estudos cl&#237;nicos<sup>17</sup> (<xref ref-type="fig" rid="figura1">fig. 1</xref>).</p>
    <fig id="figura1">
      <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gf01.jpg"/></fig>
    <p>O ultra-som intracoronariano foi realizado rotineiramente antes da interven&#231;&#227;o, ap&#243;s a angioplastia com cateter bal&#227;o, p&#243;s-braquiterapia e no seguimento tard&#237;o. Os estudos foram realizados pelo sistema CVIS (<italic>Boston Scientific Corp., Maple Grove, MN</italic>) incorporando um transdutor de 30 MHz com uma rota&#231;&#227;o de 1800rpm. Para obter a sequ&#234;ncia de imagens, o transdutor de ultra-som foi tracionado por um equipamento autom&#225;tico &#224; velocidade de 0,5mm/s. A reconstru&#231;&#227;o tridimensional da imagem foi processada por meio de um sistema computarizado (<italic>IndecSystems, Mountain View, CA</italic>).</p>
    <p>As an&#225;lises volum&#233;tricas foram calculadas a partir da f&#243;rmula de Simpson: Volume=S &#193;rea total do vaso, indentificada pela membrana el&#225;stica externa, <italic>stent</italic>, placa (membrana el&#225;stica externa &#150; <italic>stent</italic>), hiperplasia neo-intimal (HNI) e l&#250;men. Para avaliar as mudan&#231;as volum&#233;tricas de cada elemento do vaso, aos 6 meses, o valor para cada medida foi calculado em delta (Dvolume), resultando da diferen&#231;a entre os valores volum&#233;tricos obtidos no seguimento tardio e ap&#243;s interven&#231;&#227;o. Da mesma forma, calculou-se a percentagem de obstru&#231;&#227;o volum&#233;trica (%Obstru&#231;&#227;o= [volume HNI/volume <italic>stent</italic>] x 100), para os 3 per&#237;odos de avalia&#231;&#227;o (pr&#233;, p&#243;s-interven&#231;&#227;o e aos 6 meses)<sup>17-18</sup>. Ao ultra-som intracoronariano, a forma&#231;&#227;o de aneurisma foi definido como a presen&#231;a de &#225;rea luminal m&#225;xima no local tratado 50% maior do que a &#225;rea luminal no segmento de referencia normal<sup>16</sup>.</p>
    <p>A posi&#231;&#227;o incompleta do <italic>stent</italic> foi definido como 1 ou mais hastes do <italic>stent</italic> claramente separadas da parede do vaso, com evid&#234;ncia ultra-sonogr&#225;fica de fluxo sang&#252;&#237;neo atr&#225;s da haste<sup>19,20</sup>.</p>
    <p>Aferiu-se a ocorr&#234;ncia de falha do vaso alvo &#150;FVA- (&#243;bito, infarto agudo do mioc&#225;rdio, reestenose pelo crit&#233;rio binario [les&#227;o &gt;50%] e revasculariza&#231;&#227;o do vaso alvo) e a percentagem de obstru&#231;&#227;o volum&#233;trica aos 180 dias ap&#243;s a braquiterapia.</p>
    <p>A an&#225;lise estat&#237;stica foi realizada utilizando o programa SPSS vers&#227;o 8.0.0 (SPSS Inc, Chicago, Illinois, USA). As vari&#225;veis continuas foram expressas como m&#233;dias e desvio padr&#227;o, enquanto as categ&#243;ricas foram apresentadas como freq&#252;&#234;ncias absolutas e percentagens. As vari&#225;veis categ&#243;ricas foram comparadas pelo teste do qui-quadrado com corre&#231;&#227;o de continuidade ou pelo teste exato de Fisher, quando apropriado. A compara&#231;&#227;o entre as vari&#225;veis continuas foi feita por meio do teste <italic>t</italic> de "Student"com corre&#231;&#227;o do test de Welch, quando necess&#225;rio; medidas que n&#227;o apresentassem distribui&#231;&#227;o normal foram analisadas pelo teste n&#227;o-param&#233;trico de Mann-Whiteney. O n&#237;vel de signific&#226;ncia foi de p <underline>&lt;</underline>0,05. As correla&#231;&#245;es entre as mudan&#231;as das var&#237;aveis continuas foram realizadas pelo teste de correla&#231;&#227;o de Pearson.</p>
    <p>
      <bold>Resultados</bold>
    </p>
    <p>As caracter&#237;sticas cl&#237;nicas e angiogr&#225;ficas dos 30 pacientes inclu&#237;dos encontram-se na <xref ref-type="table" rid="t2">tabela II</xref>. Dez (33%) pacientes apresentavam diabetes mellitus, 44% apresentavam angina est&#225;vel, 4(13%) j&#225; tinham mais de uma interven&#231;&#227;o para o tratamento de reestenose intra-<italic>stent</italic> e o tempo medio transcorrido desde a &#250;ltima interven&#231;&#227;o foi de 7,3&#177;2,3 meses. Predominaram as les&#245;es complexas: 60% foram difusas, 17% proliferativas, 17% focais e 6% sob a forma de oclus&#227;o <sup>3</sup>.</p>
    <p content-type="asset">
      <table-wrap id="t2">
        <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gt02.jpg"/></table-wrap>
    </p>
    <p>A angioplastia com cateter bal&#227;o foi realizada em todas as les&#245;es intra-<italic>stent</italic>. Em um dos procedimentos realizou-se aterectomia rotacional antes da dilata&#231;&#227;o com bal&#227;o. No nosso estudo, n&#227;o houve nenhum caso de estenose residual &gt; 50% imediatamente ap&#243;s do procedimento. Observou-se uma dissec&#231;&#227;o tipo A (n&#227;o fluxo-limitante), que n&#227;o necessitou tratamento adicional. Em rela&#231;&#227;o &#224; braquiterapia, a aplica&#231;&#227;o foi realizada em 100% dos pacientes, sem apresentar altera&#231;&#245;es eletrocardiogr&#225;ficas sugestivas de isquemia mioc&#225;rdica durante o procedimento. Foi utilizada a fonte de 40mm de extens&#227;o, com uma dosagem m&#233;dia de 20,7&#177;2,3 Gy, aplicada em 3,8&#177;2,1min.</p>
    <p>A extens&#227;o do segmento alvo e o segmento que recebeu inj&#250;ria foram de 18,6&#177;4,1mm e 23,3&#177;3,8mm, respectivamente. O di&#226;metro luminal m&#237;nimo intra-<italic>stent</italic> e o intra-segmentar aumentaram significativamente ap&#243;s interven&#231;&#227;o (ambos p&lt;0,0001), resultando em ganhos luminais agudos de 0,91&#177;0,41mm e 0,85&#177;0,40mm, respectivamente (<xref ref-type="table" rid="tabela3">tab. III</xref>). Aos 6 meses, o seguimento angiogr&#225;fico foi realizado na totalidade dos casos. O di&#226;metro luminal m&#237;nimo intra-<italic>stent</italic> diminuiu de forma n&#227;o significante (1,98&#177;0,30mm para 1,84&#177;0,39mm aos 6 meses; p=0,13), associando-se com uma perda tardia de 0,14&#177;0,18mm. O di&#226;metro luminal m&#237;nimo intra-segmentar foi significativamente menor que o intra-<italic>stent</italic> aos 6 meses do tratamento (1,55&#177;0,40mm versus 1,84&#177;0,39mm, p=0,008), associando-se com maior perda tardia intra-segmentar (0,40&#177;0,29mm versus 0,14&#177;0,18mm<italic>;</italic> p=0,0001). Observaram-se cinco casos com reestenose angiogr&#225;fica (17%) no seguimento tardio. Um paciente apresentou reestenose na extremidade distal do <italic>stent</italic>, outro, 2 les&#245;es reesten&#243;ticas (intra-<italic>stent</italic> e em sua extremidade distal) e um terceiro apresentou reestenose no corpo da endopr&#243;tese. Dois casos apresentaram les&#245;es esten&#243;ticas na extremidade proximal do segmento irradiado.</p>
    <table-wrap id="tabela3">
      <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gt03.jpg"/></table-wrap>
    <p>O ultra-som intracoronariano foi realizado em 87% (26/30) dos pacientes imediatamente ap&#243;s interven&#231;&#227;o e aos 180 dias do seguimento tardio. Aos seis meses, o volume do tecido neointimal aumentou discretamente (DHNI=+6,75&#177;14,3mm<sup>3</sup>; p=0,19), associando-se com uma redu&#231;&#227;o n&#227;o significativa do volume da luz intra-<italic>stent</italic> (Dlumen= -10,38&#177;15,7mm<sup>3</sup>; p=0,18) (<xref ref-type="table" rid="t4">tab. IV</xref>). Houve um aumento quantitativo tanto do volume do vaso como da placa aos 6 meses, por&#233;m sem atingir signific&#226;ncia estat&#237;stica. O percentual de obstru&#231;&#227;o volum&#233;trica foi reduzido de 61,1&#177;8,1% para 26,8&#177;7,2% ap&#243;s a interven&#231;&#227;o (p&lt;0,0001), elevando-se para 30,5&#177;8,0%, aos 6 meses de seguimento cl&#237;nico (D%Obstru&#231;&#227;o= +4,7&#177;7,5%; p=0,09). N&#227;o foram observados aneurismas nem aposi&#231;&#227;o incompleta tardia dos <italic>stents</italic>.</p>
    <p content-type="asset">
      <table-wrap id="t4">
        <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gt04.jpg"/></table-wrap>
    </p>
    <p>Aos 6 meses, o volume do vaso apresentou uma correla&#231;&#227;o positiva com as mudan&#231;as no volume da placa (r=0,963, <italic>p</italic>=0,01).</p>
    <p>N&#227;o houve eventos card&#237;acos maiores durante o per&#237;odo de hospitaliza&#231;&#227;o (48,8&#177;6,2h), nem foram registrados casos de trombose subaguda. Dos 30 casos analisados no seguimento cl&#237;nico tardio houve 1 (3%) caso de trombose tardia (aos 46 dias ap&#243;s interven&#231;&#227;o), que cursou com infarto agudo do mioc&#225;rdio sem onda Q, e 5 casos de revasculariza&#231;&#227;o do vaso alvo (17%), dos quais 60% (3/5 casos) foram realizados por via percut&#226;nea. Em total o percentual de falha do vaso alvo foi de 20% nesta s&#233;rie, determinando uma sobrevida livre de eventos de 80% aos 6 meses de evolu&#231;&#227;o cl&#237;nica (<xref ref-type="table" rid="tabela5">tab. V</xref>).</p>
    <table-wrap id="tabela5">
      <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gt05.jpg"/></table-wrap>
    <p>
      <bold>Discuss&#227;o</bold>
    </p>
    <p>Em nosso estudo, a utiliza&#231;&#227;o da braquiterapia intracoronariana com o sistema Beta-Cath sugere ser um procedimento t&#233;cnicamente seguro e vi&#225;vel, apresentando-se com resultados favor&#225;veis no manejo da reestenose intra-<italic>stent</italic><sup>21,22</sup> aos seis meses seguimento cl&#237;nico (<xref ref-type="fig" rid="figura2">fig. 2</xref>).</p>
    <fig id="figura2">
      <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gf02.jpg"/></fig>
    <p>As reestenoses difusas e proliferativas, que representaram 77% dos nossos casos, s&#227;o as de pior progn&#243;stico ap&#243;s manejo percut&#226;neo. No estudo de Mehran e cols.<sup>3</sup>, esses casos apresentaram nova recidiva em 50-80% dos casos ap&#243;s a angioplastia com cateter bal&#227;o, contrastando com nossos resultados, onde a taxa de recidiva 6 meses ap&#243;s a braquiterapia foi de 17%, sugerindo a superioridade da braquiterapia sobre o tratamento convencional com bal&#227;o e confirmando os resultados de investiga&#231;&#245;es pr&#233;vias <sup>21-23</sup>.</p>
    <p>A dosagem de radia&#231;&#227;o pr&#233;-estabelecida foi liberada totalmente em todas as les&#245;es. Todos os pacientes receberam terapia antiplaquet&#225;ria (&#225;cido acetilsalic&#237;lico indefinidamente) e tienopirid&#237;nicos por um tempo m&#237;nimo de 4 meses; n&#227;o ocorreram eventos card&#237;acos maiores durante o primeiro m&#234;s. Observou-se uma (3%) oclus&#227;o tromb&#243;tica tardia, manifestada como infarto agudo do mioc&#225;rdio sem onda Q, percentagem inferior do que a dos estudos WRIST, Long-WRIST, SVG-WRIST, GAMMA-1 e BETA-WRIST (9,1% aos 5 meses ap&#243;s o procedimento)<sup>24</sup> e semelhante &#224; dos estudos WRIST-PLUS<sup>25</sup> e INHIBIT<sup>26</sup>. Apenas, uma dissec&#231;&#227;o (n&#227;o fluxo-limitante) foi documentada no final do procedimento, sem requerer tratamento adicional, embora, tardiamente, ela tenha-se associado com uma das reestenoses observadas (extremidade distal do <italic>stent</italic>). O impacto no progn&#243;stico das dissec&#231;&#245;es n&#227;o fluxo-limitantes em pacientes que realizam braquiterapia ainda &#233; desconhecido. Em duas s&#233;ries de 16 pacientes cada uma, a presen&#231;a de dissec&#231;&#227;o aguda ap&#243;s angioplastia com bal&#227;o e beta-radia&#231;&#227;o persistiu em aproximadamente 50% dos pacientes aos 6 meses de seguimento cl&#237;nico<sup>27,28</sup>, n&#227;o apresentando associa&#231;&#227;o na recorr&#234;ncia da angina ou com qualquer evento cl&#237;nico em particular<sup>28</sup>.</p>
    <p>Em rela&#231;&#227;o aos eventos cl&#237;nicos aqui documentados, nossos resultados foram similares aos encontrados em estudos pr&#233;vios que utilizaram a beta-radia&#231;&#227;o intracoronariana, nos quais a incid&#234;ncia de eventos card&#237;acos maiores situou-se entre 18% e 33%: START(18%)<sup>29</sup>, INHIBIT(22%)<sup>26</sup> e BETA-WRIST(33%)<sup>30</sup>. De forma an&#225;loga, a taxa de reestenose nesses estudos variou entre 15% e 29%<sup>22,26,30</sup>.</p>
    <p>Quando &#233; comparada a perda tardia entre os segmentos definidos angiograficamente, evidenciou-se que o di&#226;metro luminal m&#237;nimo intra-segmentar apresentou uma redu&#231;&#227;o estat&#237;sticamente maior que o di&#226;metro luminal m&#237;nimo intra-<italic>stent</italic>, em decorr&#234;ncia da les&#227;o causada pelo bal&#227;o nos segmentos adjacentes ao <italic>stent</italic>. Esse fen&#244;meno, descrito como "perda geogr&#225;fica", observado em 13% dos nossos casos, &#233; caracterizado principalmente por uma radia&#231;&#227;o inadequada no segmento que recebeu inj&#250;ria<sup>31</sup>. Teoricamente, esta condi&#231;&#227;o ocorre quando danificam-se as extremidades do segmento irradiado, nos quais, por defini&#231;&#227;o, a dose emitida &#233; muito baixa. Em uma an&#225;lise restrospectiva<sup>31</sup> de 50 pacientes consecutivos tratados com radia&#231;&#227;o beta ap&#243;s angioplastia com cateter bal&#227;o ou <italic>stent</italic>, a incid&#234;ncia deste fen&#244;meno foi de 32%.</p>
    <p>A an&#225;lise volum&#233;trica pelo ultra-som intracoronariano mostrou que o crescimento do tecido neointimal foi discreto aos 6 meses do seguimento cl&#237;nico, resultado semelhante ao de outros estudos<sup>32</sup>. Quanto ao crescimento do vaso (+21,4&#177;27,8 mm<sup>3</sup>), observado aos 180 dias de tratamento, sugere que a radia&#231;&#227;o beta intracoronariana induziu um remodelamento positivo da pared arterial, caracterizado por um processo "acomodativo" da placa (correla&#231;&#227;o no aumento do Dmembrana el&#225;stica externa vs. Dplaca, r=0,963, <italic>p</italic>&lt;0,01), preservando o volume da luz intra-<italic>stent</italic>. Dados experimentais t&#234;m sugerido que a radia&#231;&#227;o tem um efeito no remodelamento do vaso devido &#224; modifica&#231;&#227;o da resposta celular na camada advent&#237;cia<sup>33,34</sup>. O remodelamento positivo, acomodando o crescimento neo-intimal ap&#243;s 6 meses, tem sido demonstrado pelas an&#225;lises ultrassonogr&#225;ficas<sup>35</sup>, considerando-se que outros estudos n&#227;o relataram mudan&#231;as da &#225;rea total do vaso ou da placa atr&#225;s do <italic>stent</italic><sup>27</sup>.</p>
    <p>Comparada com a radia&#231;&#227;o gama, a radia&#231;&#227;o beta apresenta menor profundidade de penetra&#231;&#227;o, minimizando a exposi&#231;&#227;o de radia&#231;&#227;o para pacientes e operadores e, conseq&#252;entemente, menor requerimento de r&#225;dio-protec&#231;&#227;o. Por&#233;m, a queda r&#225;pida da dose de radia&#231;&#227;o beta dentro dos 2-5mm de profundidade est&#225; associada a uma libera&#231;&#227;o de dose menos homog&#234;nea<sup>32</sup>. Al&#233;m disto, o "efeito de escudo" produzido pelas hastes do <italic>stent</italic> estaria associado a uma atenua&#231;&#227;o da dose de radia&#231;&#227;o atrav&#233;s das suas hastes, maior do que 15%<sup>36</sup>. Quando foram comparados os resultados pelo ultra-som intracoronariano em dois grandes estudos<sup>13,15</sup>, observou-se que a radia&#231;&#227;o beta apresentou maior beneficio que a gama na preven&#231;&#227;o da hiperplasia neo-intimal no interior do <italic>stent</italic><sup>37,38</sup>.</p>
    <p>Por fim, &#233; importante ressaltar que a participa&#231;&#227;o latino-americana no desenvolvimento desta inovadora op&#231;&#227;o terap&#233;utica no manejo das les&#245;es esten&#243;ticas, tem sido determinante. A primeira experi&#234;ncia cl&#237;nica registrada com radia&#231;&#227;o em arterias coron&#225;rias humanas foi realizada por Condado e cols., na Venezuela<sup>39</sup>, que introduziram uma guia de<sup>192</sup> iridio no interior de um cateter n&#227;o centralizado na luz do vaso, por meio de um dispositivo de libera&#231;&#227;o manual, demonstrando ass&#237;m, que a administra&#231;&#227;o de radia&#231;&#227;o no interior da arteria coron&#225;ria era fact&#237;vel e segura, embora com elevadas taxas de restenose observada nesta experi&#234;ncia inicial.</p>
    <p>Este estudo consistiu de uma serie inicial e consecutiva de casos de reestenose intra-<italic>stent</italic> tratados no nosso servi&#231;o, com evolu&#231;&#227;o cl&#237;nica tardia limitada a 6 meses. Devido ao n&#250;mero relativamente pequeno de pacientes avaliados e pelo desenho do estudo (n&#227;o aleatorizado, sem grupo controle, excluindo-se casos de maior complexidade), os resultados aqui documentados n&#227;o devem ser extrapolados para a totalidade dos casos que cursam com esta afec&#231;&#227;o.</p>
    <p>Apesar dos eventos cl&#237;nicos observados no seguimento tardio n&#227;o diferirem com os dos grandes estudos randomizados, n&#227;o se pode afirmar que s&#227;o clinicamente equivalentes, pois o tamanho da nossa amostra inviabiliza esta conclus&#227;o. Independentemente das observa&#231;&#245;es j&#225; citadas, este registro permitiu-nos uma experi&#234;ncia cl&#237;nica inicial satisfat&#243;ria com o uso desta t&#233;cnica. Os pacientes do estudo permanecem em evolu&#231;&#227;o cl&#237;nica, e novos casos s&#227;o incorporados progressivamente.</p>
    <p>Concluindo, o presente estudo sugere que a braquiterapia intracoronariana usando o sistema Beta-Cath<sup>TM</sup> ap&#243;s angioplastia com cateter bal&#227;o representa uma op&#231;&#227;o terap&#234;utica segura e eficaz para pacientes com reestenose intra-<italic>stent</italic>. Desta forma, em casos com as caracter&#237;sticas cl&#237;nicas e angiogr&#225;ficas semelhantes &#224;s deste estudo, a braquiterapia intracoronariana pode ser considerada parte do arsenal terap&#234;utico de escolha no tratamento desta afec&#231;&#227;o. Estes resultados iniciais somam-se aos de estudos cl&#237;nicos randomizados previamente realizados, atestando a seguran&#231;a, factibilidade e pertin&#234;ncia do m&#233;todo.</p>
    <p>
      <fn id="back10" fn-type="corresp">
        <p>Endere&#231;o para correspond&#234;ncia</p>
        <p>Juan Simon Mu&#241;oz </p>
        <p> Av. Dante Pazzanese, 500 </p>
        <p>S&#227;o Paulo &#150; SP Cep 04012-909 </p>
        <p> E-mail: </p>
        <p>
          <email xlink:href="jsmuro@hotmail.com">jsmuro@hotmail.com</email>
        </p>
      </fn>
    </p>
    <p>Recebido para Publica&#231;&#227;o 16/4/03 </p>
    <p>Aceito 6/7/03</p>
  </body>
  <back>
    <ref-list>
      <ref id="B1">
        <mixed-citation>1. Kastrati    A, Schoming A, Elezi S et al. Predictive factors of restenosis after coronary    stent placement. J Am Coll Cardiol 1997; 30: 1428-36.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Predictive factors of restenosis after coronary stent placement</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>1997</year>
          </date>
          <fpage>1428</fpage>
          <lpage>36</lpage>
          <volume>30</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Kastrati</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Schoming</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Elezi</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Van Belle    E, Baurers C, Hurbert E et al. Restenosis rates in diabetic patients: a comparison    of coronary stenting and balloon angioplasty in native coronary vessels. Circulation    1997; 96: 1454-60.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Restenosis rates in diabetic patients: a comparison of coronary stenting and balloon angioplasty in native coronary vessels</article-title>
          <source>Circulation</source>
          <date>
            <year>1997</year>
          </date>
          <fpage>1454</fpage>
          <lpage>60</lpage>
          <volume>96</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Van</surname>
              <given-names>Belle E</given-names>
            </name>
            <name>
              <surname>Baurers</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Hurbert</surname>
              <given-names>E</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. Merhan    R, Dangas D, Abizaid AS et al. Angiographic patterns of in-stent restenosis:    classification and implications for long-term outcome. Circulation 1999; 100:    1872-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome</article-title>
          <source>Circulation</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>1872</fpage>
          <lpage>8</lpage>
          <volume>100</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Merhan</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Dangas</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Abizaid</surname>
              <given-names>AS</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Dussaillant    GR, Mintz GS, Pichard AD et al. Small stent size and intimal hyperplasia contribute    to restenosis: a volumetric intravascular ultrasound analysis. J Am Coll Cardiol    1995; 26: 720-4.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Small stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>720</fpage>
          <lpage>4</lpage>
          <volume>26</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Dussaillant</surname>
              <given-names>GR</given-names>
            </name>
            <name>
              <surname>Mintz</surname>
              <given-names>GS</given-names>
            </name>
            <name>
              <surname>Pichard</surname>
              <given-names>AD</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. Hoffman    R, Mintz GS, Dussaillant GR et al. Patterns and mechanisms of in-stent restenosis:    a serial intravascular ultrasound study. Circulation 1996; 94: 1247-54.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Patterns and mechanisms of in-stent restenosis: a serial intravascular ultrasound study</article-title>
          <source>Circulation</source>
          <date>
            <year>1996</year>
          </date>
          <fpage>1247</fpage>
          <lpage>54</lpage>
          <volume>94</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Hoffman</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Mintz</surname>
              <given-names>GS</given-names>
            </name>
            <name>
              <surname>Dussaillant</surname>
              <given-names>GR</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B6">
        <mixed-citation>6. Baim    DS, Levine MJ, Leon MB, Levine S, Ellis SG, Schatz RA. Management of restenosis    within the Palmaz-Schatz coronary stent (the US multicenter experience). Am    J Cardiol 1993; 71: 364-6.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Management of restenosis within the Palmaz-Schatz coronary stent (the US multicenter experience)</article-title>
          <source>Am J Cardiol</source>
          <date>
            <year>1993</year>
          </date>
          <fpage>364</fpage>
          <lpage>6</lpage>
          <volume>71</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Baim</surname>
              <given-names>DS</given-names>
            </name>
            <name>
              <surname>Levine</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Leon</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Levine</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Ellis</surname>
              <given-names>SG</given-names>
            </name>
            <name>
              <surname>Schatz</surname>
              <given-names>RA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B7">
        <mixed-citation>7. Merhan    R, Mintz GS, Satler LF et al. Treatment of in-stent restenosis with excimer    laser coronary angioplasty: mechanisms and results compared to PTCA alone. Circulation    1997; 96: 2183-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Treatment of in-stent restenosis with excimer laser coronary angioplasty: mechanisms and results compared to PTCA alone</article-title>
          <source>Circulation</source>
          <date>
            <year>1997</year>
          </date>
          <fpage>2183</fpage>
          <lpage>9</lpage>
          <volume>96</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Merhan</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Mintz</surname>
              <given-names>GS</given-names>
            </name>
            <name>
              <surname>Satler</surname>
              <given-names>LF</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B8">
        <mixed-citation>8. Sharma    SK, Duvvuri S, Dangas G et al. Rotational atherectomy for in-stent restenosis:    acute and long-term results of the first 100 cases. J Am Coll Cardiol 1998;    32: 1358-65.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Rotational atherectomy for in-stent restenosis: acute and long-term results of the first 100 cases</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>1358</fpage>
          <lpage>65</lpage>
          <volume>32</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Sharma</surname>
              <given-names>SK</given-names>
            </name>
            <name>
              <surname>Duvvuri</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Dangas</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B9">
        <mixed-citation>9. Teirstein    PS, Massullo V, Jani S et al. Catheter-based radiotherapy to inhibit restenosis    after coronary stenting. N Engl J Med 1997; 336: 1697-703.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Catheter-based radiotherapy to inhibit restenosis after coronary stenting</article-title>
          <source>N Engl J Med</source>
          <date>
            <year>1997</year>
          </date>
          <fpage>1697</fpage>
          <lpage>703</lpage>
          <volume>336</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Teirstein</surname>
              <given-names>PS</given-names>
            </name>
            <name>
              <surname>Massullo</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Jani</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B10">
        <mixed-citation>10. Casterella    PJ, Teirstein PS. Prevention of coronary restenosis. Cardiol Rev 1999; 7: 19-31.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Prevention of coronary restenosis</article-title>
          <source>Cardiol Rev</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>19</fpage>
          <lpage>31</lpage>
          <volume>7</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Casterella</surname>
              <given-names>PJ</given-names>
            </name>
            <name>
              <surname>Teirstein</surname>
              <given-names>PS</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B11">
        <mixed-citation>11. Hall    EJ. DNA strand breaks and chromosomal aberrations. In: Hall EJ. Radiobiology    for the Radiologist. Philadelphia, Penn: J.B. Lippincott Company; 1994: 15-73.</mixed-citation>
        <element-citation publication-type="book">
          <source>Radiobiology for the Radiologist</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>15</fpage>
          <lpage>73</lpage>
          <person-group person-group-type="author">
            <name>
              <surname>Hall</surname>
              <given-names>EJ</given-names>
            </name>
            <name>
              <surname>Hall</surname>
              <given-names>EJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B12">
        <mixed-citation>12. Rubin    P, Soni A, Williams JP. The molecular and cellular biologic basis for the radiation    treatment of benign proliferative diseases. Semin Radiat Oncol 1999; 9: 203-14.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>The molecular and cellular biologic basis for the radiation treatment of benign proliferative diseases</article-title>
          <source>Semin Radiat Oncol</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>203</fpage>
          <lpage>14</lpage>
          <volume>9</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Rubin</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Soni</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Williams</surname>
              <given-names>JP</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B13">
        <mixed-citation>13. Waksman    R, White LR, Chan RC et al. Intracoronary g-radiation therapy after angioplasty    inhibits recurrence in patients with in-stent restenosis. Circulation 2000;    101: 2165-71.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Intracoronary g-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis</article-title>
          <source>Circulation</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>2165</fpage>
          <lpage>71</lpage>
          <volume>101</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Waksman</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>White</surname>
              <given-names>LR</given-names>
            </name>
            <name>
              <surname>Chan</surname>
              <given-names>RC</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B14">
        <mixed-citation>14. Leon    MB, Teirstein PS, Moses JW et al. Localized intracoronary gamma radiation therapy    to inhibit the recurrence of restenosis after stenting. N Engl J Med 2001; 344:    250-6.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Localized intracoronary gamma radiation therapy to inhibit the recurrence of restenosis after stenting</article-title>
          <source>N Engl J Med</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>250</fpage>
          <lpage>6</lpage>
          <volume>344</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Leon</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Teirstein</surname>
              <given-names>PS</given-names>
            </name>
            <name>
              <surname>Moses</surname>
              <given-names>JW</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B15">
        <mixed-citation>15. Waksman    R, Bhargava B, White L et al. Intracoronary beta-radiation therapy inhibits    recurrence of in-stent restenosis. Circulation 2000; 101: 1895-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Intracoronary beta-radiation therapy inhibits recurrence of in-stent restenosis</article-title>
          <source>Circulation</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>1895</fpage>
          <lpage>8</lpage>
          <volume>101</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Waksman</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Bhargava</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>White</surname>
              <given-names>L</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B16">
        <mixed-citation>16. Akiko    Maehara, Gary S Mintz, Javed M Ahmed et al. An Intravascular Ultrasound Classification    of Angiographic Coronary Artery Aneurysms. Am J Cardiol 2001; 88: 365-70.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>An Intravascular Ultrasound Classification of Angiographic Coronary Artery Aneurysms</article-title>
          <source>Am J Cardiol</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>365</fpage>
          <lpage>70</lpage>
          <volume>88</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Akiko</surname>
              <given-names>Maehara</given-names>
            </name>
            <name>
              <surname>Gary</surname>
              <given-names>S Mintz</given-names>
            </name>
            <name>
              <surname>Javed</surname>
              <given-names>M Ahmed</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B17">
        <mixed-citation>17. Sabat&#233;    M, Costa MA, Kozuma K et al. Methodological and clinical implications of the    relocation of the minimal luminal diameter after intracoronary radiation therapy.    J Am Coll Cardiol 2000; 36: 1536-41.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Methodological and clinical implications of the relocation of the minimal luminal diameter after intracoronary radiation therapy</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>1536</fpage>
          <lpage>41</lpage>
          <volume>36</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Sabat&#233;</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Costa</surname>
              <given-names>MA</given-names>
            </name>
            <name>
              <surname>Kozuma</surname>
              <given-names>K</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B18">
        <mixed-citation>18. Kearney    PP, Ramo MP, Shaw TR et al. Analysis of reproducibly of reference lumen quantification    with intravascular ultrasound in stented coronary arteries. Cathet Cardiovasc    Diagn 1997; 40: 1-7.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Analysis of reproducibly of reference lumen quantification with intravascular ultrasound in stented coronary arteries</article-title>
          <source>Cathet Cardiovasc Diagn</source>
          <date>
            <year>1997</year>
          </date>
          <fpage>1</fpage>
          <lpage>7</lpage>
          <volume>40</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Kearney</surname>
              <given-names>PP</given-names>
            </name>
            <name>
              <surname>Ramo</surname>
              <given-names>MP</given-names>
            </name>
            <name>
              <surname>Shaw</surname>
              <given-names>TR</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B19">
        <mixed-citation>19. Kozuma    K, Costa MA, Sabat&#233; M et al. Three-dimensional intravascular ultrasound    assessment of noninjured edges of b-irradiated coronary segments. Circulation    2000; 102: 1484-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Three-dimensional intravascular ultrasound assessment of noninjured edges of b-irradiated coronary segments</article-title>
          <source>Circulation</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>1484</fpage>
          <lpage>9</lpage>
          <volume>102</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Kozuma</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Costa</surname>
              <given-names>MA</given-names>
            </name>
            <name>
              <surname>Sabat&#233;</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B20">
        <mixed-citation>20. Honda    Y, Grube E, de la Fuente L et al. Novel drug-delivery stent: intravascular ultrasound    observations from the first human experience with the QP2-eluting polymer stent    system. Circulation 2001; 104: 380-3.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Novel drug-delivery stent: intravascular ultrasound observations from the first human experience with the QP2-eluting polymer stent system</article-title>
          <source>Circulation</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>380</fpage>
          <lpage>3</lpage>
          <volume>104</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Honda</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Grube</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>de la Fuente</surname>
              <given-names>L</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B21">
        <mixed-citation>21. Kobayashi    Y, Honda Y, Christie LG et al. Long-term vessel response to a self-expanding    coronary stent: a serial volumetric intravascular ultrasound analysis from the    ASSURE trial. J Am Coll Cardiol 2001; 1329-34.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Long-term vessel response to a self-expanding coronary stent: a serial volumetric intravascular ultrasound analysis from the ASSURE trial</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>1329</fpage>
          <lpage>34</lpage>
          <person-group person-group-type="author">
            <name>
              <surname>Kobayashi</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Honda</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Christie</surname>
              <given-names>LG</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B22">
        <mixed-citation>22. Regar    E, Kozuma K, Sianos G et al. Routine intracoronary beta-irradiation: Acute and    one year outcome in patients at high risk for recurrence of stenosis. Eur Heart    J 2002; 23: 1038-44.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Routine intracoronary beta-irradiation: Acute and one year outcome in patients at high risk for recurrence of stenosis</article-title>
          <source>Eur Heart J</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>1038</fpage>
          <lpage>44</lpage>
          <volume>23</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Regar</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Kozuma</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Sianos</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B23">
        <mixed-citation>23. King    SB, 3<sup>rd</sup>, Williams DO, Chougule P et al. Endovascular beta-radiation    to reduce restenosis after coronary balloon angioplasty: results of the beta    energy restenosis trial (BERT). Circulation 1998; 97: 2025-30.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Endovascular beta-radiation to reduce restenosis after coronary balloon angioplasty: results of the beta energy restenosis trial (BERT)</article-title>
          <source>Circulation</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>2025</fpage>
          <lpage>30</lpage>
          <volume>97</volume>
          <person-group person-group-type="author">
            <name>
              <surname>King</surname>
              <given-names>SB</given-names>
            </name>
            <name>
              <surname>3rd, Williams</surname>
              <given-names>DO</given-names>
            </name>
            <name>
              <surname>Chougule</surname>
              <given-names>P</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B24">
        <mixed-citation>24. Urban    P, Serruys PW, Baumgart D et al. Clinical application of intracoronary beta    brachytherapy using sr/Y90 source trains the European surveillance registry    with the novoste beta-cath system. Eur Heart J 2001; 22: 4.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Clinical application of intracoronary beta brachytherapy using sr/Y90 source trains the European surveillance registry with the novoste beta-cath system</article-title>
          <source>Eur Heart J</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>4</fpage>
          <volume>22</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Urban</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Serruys</surname>
              <given-names>PW</given-names>
            </name>
            <name>
              <surname>Baumgart</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B25">
        <mixed-citation>25. Waksman    R, Bhargava B, Mintz GS et al. Late total occlusion after intracoronary brachytherapy    for patients with in-stent restenosis. J Am Coll Cardiol 2000; 36: 65-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Late total occlusion after intracoronary brachytherapy for patients with in-stent restenosis</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>65</fpage>
          <lpage>8</lpage>
          <volume>36</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Waksman</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Bhargava</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Mintz</surname>
              <given-names>GS</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B26">
        <mixed-citation>26. Waksman    R, Ajani AE, White RL et al. Prolonged antiplatelet therapy to prevent late    thrombosis after intracoronary g-radiation in patients whit in-stent restenosis:    Washington Radiation for In-Stent Restenosis Trial Plus 6 Months of Clopidogrel    (WRIST PLUS). Circulation 2001; 103: 2332-5.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Prolonged antiplatelet therapy to prevent late thrombosis after intracoronary g-radiation in patients whit in-stent restenosis: Washington Radiation for In-Stent Restenosis Trial Plus 6 Months of Clopidogrel (WRIST PLUS)</article-title>
          <source>Circulation</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>2332</fpage>
          <lpage>5</lpage>
          <volume>103</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Waksman</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Ajani</surname>
              <given-names>AE</given-names>
            </name>
            <name>
              <surname>White</surname>
              <given-names>RL</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B27">
        <mixed-citation>27. Waksman    R, Raizner AE, Yeung AC et al. Localized intracoronary b radiation therapy to    inhibit recurrence of in-stent restenosis. Lancet 2002; 359: 551-7.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Localized intracoronary b radiation therapy to inhibit recurrence of in-stent restenosis</article-title>
          <source>Lancet</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>551</fpage>
          <lpage>7</lpage>
          <volume>359</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Waksman</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Raizner</surname>
              <given-names>AE</given-names>
            </name>
            <name>
              <surname>Yeung</surname>
              <given-names>AC</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B28">
        <mixed-citation>28. Meerkin    D, Tardif JC, Crocker IR et al. Effects of intacoronary beta-radiation therapy    after coronary angioplasty: an intravascular ultrasound study. Circulation 1999;    99: 1660-5.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Effects of intacoronary beta-radiation therapy after coronary angioplasty: an intravascular ultrasound study</article-title>
          <source>Circulation</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>1660</fpage>
          <lpage>5</lpage>
          <volume>99</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Meerkin</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Tardif</surname>
              <given-names>JC</given-names>
            </name>
            <name>
              <surname>Crocker</surname>
              <given-names>IR</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B29">
        <mixed-citation>29. Kay    IP, Sabat&#233; M, Van Langenhove G et al. Outcome from balloon induced coronary    artery dissection after intracoronary beta radiation. Heart 2000; 83: 332-7.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Outcome from balloon induced coronary artery dissection after intracoronary beta radiation</article-title>
          <source>Heart</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>332</fpage>
          <lpage>7</lpage>
          <volume>83</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Kay</surname>
              <given-names>IP</given-names>
            </name>
            <name>
              <surname>Sabat&#233;</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Van</surname>
              <given-names>Langenhove G</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B30">
        <mixed-citation>30. Ajani    A, Kim H-S, Waksman R. Clinical trials of vascular brachytherapy for in-stent    restenosis: update. Cardiovasc Radiat Med 2001; 2: 107-13.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Clinical trials of vascular brachytherapy for in-stent restenosis: update</article-title>
          <source>Cardiovasc Radiat Med</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>107</fpage>
          <lpage>13</lpage>
          <volume>2</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Ajani</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Kim</surname>
              <given-names>H-S</given-names>
            </name>
            <name>
              <surname>Waksman</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B31">
        <mixed-citation>31. Salame    MY, Verheye S, Crocker IR et al. Intracoronary radiation therapy: Review Article.    Eur Heart J 2001; 22: 629-47.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Intracoronary radiation therapy: Review Article</article-title>
          <source>Eur Heart J</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>629</fpage>
          <lpage>47</lpage>
          <volume>22</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Salame</surname>
              <given-names>MY</given-names>
            </name>
            <name>
              <surname>Verheye</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Crocker</surname>
              <given-names>IR</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B32">
        <mixed-citation>32. Sabat&#233;    M, Costa MA, Kozuma K et al. Geographic miss: a cause of treatment failure in    radio-oncology applied to intracoronary radiation therapy. Circulation 2000;    101: 2467-71.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Geographic miss: a cause of treatment failure in radio-oncology applied to intracoronary radiation therapy</article-title>
          <source>Circulation</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>2467</fpage>
          <lpage>71</lpage>
          <volume>101</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Sabat&#233;</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Costa</surname>
              <given-names>MA</given-names>
            </name>
            <name>
              <surname>Kozuma</surname>
              <given-names>K</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B33">
        <mixed-citation>33. Hong    M-K, Park S-W, Moon D-H et al. Intravascular ultrasound analysis of beta radiation    therapy for diffuse in-stent restenosis to inhibit intimal hyperplasia. Cathet    Cardiovasc Intervent 2001; 54: 169-73.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Intravascular ultrasound analysis of beta radiation therapy for diffuse in-stent restenosis to inhibit intimal hyperplasia</article-title>
          <source>Cathet Cardiovasc Intervent</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>169</fpage>
          <lpage>73</lpage>
          <volume>54</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Hong</surname>
              <given-names>M-K</given-names>
            </name>
            <name>
              <surname>Park</surname>
              <given-names>S-W</given-names>
            </name>
            <name>
              <surname>Moon</surname>
              <given-names>D-H</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B34">
        <mixed-citation>34. Waskman    R, Rodriguez JC, Robinson KA et al. Effect of intravascular irradiation on cell    proliferation, apoptosis, and vascular remodeling after balloon overstretch    injury of porcine coronary arteries. Circulation 1997; 96: 1944-52.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Effect of intravascular irradiation on cell proliferation, apoptosis, and vascular remodeling after balloon overstretch injury of porcine coronary arteries</article-title>
          <source>Circulation</source>
          <date>
            <year>1997</year>
          </date>
          <fpage>1944</fpage>
          <lpage>52</lpage>
          <volume>96</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Waskman</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Rodriguez</surname>
              <given-names>JC</given-names>
            </name>
            <name>
              <surname>Robinson</surname>
              <given-names>KA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B35">
        <mixed-citation>35. Wilcox    JN, Waksman R, King SB et al. The role of adventicia in the arterial response    to angioplasty: the effect of intravascular radiation. Int J Radiat Oncol Biol    Phys 1996; 36: 789-96.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>The role of adventicia in the arterial response to angioplasty: the effect of intravascular radiation</article-title>
          <source>Int J Radiat Oncol Biol Phys</source>
          <date>
            <year>1996</year>
          </date>
          <fpage>789</fpage>
          <lpage>96</lpage>
          <volume>36</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Wilcox</surname>
              <given-names>JN</given-names>
            </name>
            <name>
              <surname>Waksman</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>King</surname>
              <given-names>SB</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B36">
        <mixed-citation>36. Sabat&#233;    M, Serruys PW, Van der Giessen WJ et al. Geometric vascular remodeling after    balloon angioplasty and beta-radiation therapy: A three-dimensional intravascular    ultrasound study. Circulation 1999; 100: 1182-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Geometric vascular remodeling after balloon angioplasty and beta-radiation therapy: A three-dimensional intravascular ultrasound study</article-title>
          <source>Circulation</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>1182</fpage>
          <lpage>8</lpage>
          <volume>100</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Sabat&#233;</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Serruys</surname>
              <given-names>PW</given-names>
            </name>
            <name>
              <surname>Vander Giessen</surname>
              <given-names>WJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B37">
        <mixed-citation>37. Amols    HI, Trichter F, Weinberger J. Intracoronary radiation for prevention of restenosis:    dose perturbations caused by stents. Circulation 1998; 98: 2024-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Intracoronary radiation for prevention of restenosis: dose perturbations caused by stents</article-title>
          <source>Circulation</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>2024</fpage>
          <lpage>9</lpage>
          <volume>98</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Amols</surname>
              <given-names>HI</given-names>
            </name>
            <name>
              <surname>Trichter</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Weinberger</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B38">
        <mixed-citation>38. Bhargava    B, Mintz GS, Mehran R et al. Serial volumetric intravascular ultrasound analysis    of the efficacy of beta irradiation in preventing recurrent in-stent restenosis.    Am J Cardiol 2000; 85: 651-3.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Serial volumetric intravascular ultrasound analysis of the efficacy of beta irradiation in preventing recurrent in-stent restenosis</article-title>
          <source>Am J Cardiol</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>651</fpage>
          <lpage>3</lpage>
          <volume>85</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Bhargava</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Mintz</surname>
              <given-names>GS</given-names>
            </name>
            <name>
              <surname>Mehran</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B39">
        <mixed-citation>39. Condado    JA, Waksman R, Gurdiel O et al. Long-term angiographic and clinical outcome    after percutaneous transluminal coronary angioplasty and intracoronary radiation    therapy in humans. Circulation 1997; 96: 727-32.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Long-term angiographic and clinical outcome after percutaneous transluminal coronary angioplasty and intracoronary radiation therapy in humans</article-title>
          <source>Circulation</source>
          <date>
            <year>1997</year>
          </date>
          <fpage>727</fpage>
          <lpage>32</lpage>
          <volume>96</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Condado</surname>
              <given-names>JA</given-names>
            </name>
            <name>
              <surname>Waksman</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Gurdiel</surname>
              <given-names>O</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Articles</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Intracoronary brachytherapy. Treatment of in-stent restenosis with the Beta-Cath system: initial experience in Latin America</article-title>
      </title-group>
      <abstract xml:lang="en">
        <p>OBJECTIVE: To assess the safety and efficacy of intracoronary brachytherapy using the Beta-Cath systemTM for preventing recurrence of in-stent restenosis (ISR), by analyzing clinical, angiographic, and intracoronary ultrasound (ICUS) results. METHODS: This study assessed 30 patients with ISR in native coronary arteries who underwent balloon catheter angioplasty followed by intracoronary beta radiation with the Beta-Cath systemTM (90Sr/Y). RESULTS: The study comprised complex, extensive (18.66&#177;4.15 mm) restenotic lesions, 77% of which were of the diffuse-proliferative type. Brachytherapy was successful in 100% of the cases. The mean radiation dose used was 20.7&#177;2.3 Gy, released for a mean period of 3.8&#177;2.1 minutes. On late follow-up, the in-stent minimum luminal diameter (MLD) slightly decreased (from 1.98&#177;0.30 mm to 1.84&#177;0.39 mm at 6 months; P=0.13), with a late loss of 0.14&#177;0.18 mm. The intrasegmentary MLD was significantly smaller than the in-stent diameter (1.55&#177;0.40 mm vs 1.84&#177;0.39 mm; P=0.008), and was associated with a more significant late loss (0.40&#177;0.29 mm vs 0.14&#177;0.18 mm; P=0.0001). On ICUS, a mild increase of 6.8&#177;14.3 mm&#179; in the neointimal tissue was observed at 6 months (P=0.19), and the percentage of volumetric obstruction increased by 4.7&#177;7.5%. Binary restenosis and revascularization of the target vessel recurred in 17% of the cases; late occlusion associated with myocardial infarction occurred in 1 case (3%). Event-free survival was 80%. CONCLUSION: The management of in-stent restenosis with intracoronary beta radiation proved to be a safe and effective procedure, with a high rate of immediate success, representing a therapeutic option for inhibiting neointimal hyperplasia.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>in-stent restenosis</kwd>
        <kwd>brachytherapy</kwd>
        <kwd>Beta-Cath system</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>ORIGINAL ARTICLE</bold>
      </p>
      <p>Intracoronary brachytherapy. Treatment of in-stent restenosis with the Beta-Cath system. Initial experience in Latin America</p>
      <p>
        <bold>Juan Simon Mu&#241;oz; Fausto Feres; Alexandre C. Abizaid; Luiz A. Mattos; Rodolfo Staico; Marinella Centemero; Luiz F. Tanajura; Ibraim Pinto; Amanda G.M.R. Sousa; J. Eduardo Sousa</bold>
      </p>
      <p>Instituto Dante Pazzanese de Cardiologia</p>
      <p>S&#227;o Paulo, SP - Brazil</p>
      <p>
        <xref ref-type="corresp" rid="back10-body2">Correspondence</xref>
      </p>
      <p><bold>OBJECTIVE: </bold>To assess the safety and efficacy of intracoronary brachytherapy using the Beta-Cath system<sup>TM</sup> for preventing recurrence of in-stent restenosis (ISR), by analyzing clinical, angiographic, and intracoronary ultrasound (ICUS) results.</p>
      <p><bold>METHODS: </bold>This study assessed 30 patients with ISR in native coronary arteries who underwent balloon catheter angioplasty followed by intracoronary beta radiation with the Beta-Cath system<sup>TM</sup> (<sup>90</sup>Sr/Y).</p>
      <p><bold>RESULTS: </bold>The study comprised complex, extensive (18.66&#177;4.15 mm) restenotic lesions, 77% of which were of the diffuse-proliferative type. Brachytherapy was successful in 100% of the cases. The mean radiation dose used was 20.7&#177;2.3 Gy, released for a mean period of 3.8&#177;2.1 minutes. On late follow-up, the in-stent minimum luminal diameter (MLD) slightly decreased (from 1.98&#177;0.30 mm to 1.84&#177;0.39 mm at 6 months; P=0.13), with a late loss of 0.14&#177;0.18 mm. The intrasegmentary MLD was significantly smaller than the in-stent diameter (1.55&#177;0.40 mm vs 1.84&#177;0.39 mm; P=0.008), and was associated with a more significant late loss (0.40&#177;0.29 mm vs 0.14&#177;0.18 mm; P=0.0001). On ICUS, a mild increase of 6.8&#177;14.3 mm<sup>3</sup> in the neointimal tissue was observed at 6 months (P=0.19), and the percentage of volumetric obstruction increased by 4.7&#177;7.5%. Binary restenosis and revascularization of the target vessel recurred in 17% of the cases; late occlusion associated with myocardial infarction occurred in 1 case (3%). Event-free survival was 80%.</p>
      <p><bold>CONCLUSION: </bold>The management of in-stent restenosis with intracoronary beta radiation proved to be a safe and effective procedure, with a high rate of immediate success, representing a therapeutic option for inhibiting neointimal hyperplasia.</p>
      <p>Key words: in-stent restenosis, brachytherapy, Beta-Cath system</p>
      <p>Although implantation of coronary stents has become the most common percutaneous procedure for myocardial revascularization in recent decades, the presence of restenosis remains the major limitation of the procedure, and its solution is one of the greatest challenges in current interventional cardiology <sup>1</sup>. Recurrence of stenosis after coronary stent implantation ranges from 7 to 37% of the cases, depending on the clinical characteristics of the patient, the morphological characteristics of the lesion, and the techniques of the procedure <sup>2-4</sup>. In-stent restenosis is mainly caused by focal or diffuse proliferation of the neointimal tissue <sup>4,5</sup>. The incidence of major cardiac events, especially revascularization of the target vessel, after conventional treatment of in-stent restenosis is high (30%-80%), independently of the technique and instrumentation used <sup>6-9</sup>.</p>
      <p>Brachytherapy is a promising treatment for the reduction of new in-stent restenosis, based on the potential of inhibition exerted by radiation on the proliferation of smooth muscle cells, which are the major constituents of neointimal tissue <sup>10</sup>. It acts through an active isotope, released to block the mitotic phase of the cell cycle, causing a double rupture in the DNA strand of the smooth muscle cell <sup>11,12</sup>.</p>
      <p>Previous studies on balloon catheter angioplasty followed by intracoronary gamma-radiation treatment with iridium-192 <sup>9,13,14</sup> or intracoronary beta radiation with strontium/yttrium 90 (Sr<sup>90</sup>/Y<sup>90</sup>) <sup>15</sup> reported a reduction in clinical and angiographic diffuse recurrences.</p>
      <p>Our objective was to assess the safety and feasibility of intracoronary brachytherapy after balloon catheter angioplasty using the Beta-Cath system<sup>TM</sup> (Novoste Corp., Norcross, Georgia, USA), as well as to analyze the clinical, angiographic, and intracoronary ultrasonographic results immediately after the intervention and at 180 days of late follow-up.</p>
      <p>
        <bold>Methods</bold>
      </p>
      <p>From August 2001 to September 2002, 30 patients with in-stent restenosis, antecedents of stent implantation in native coronary arteries, and symptoms of angina or silent ischemia were included in the study. The angiographic criteria of inclusion were as follows: stenosis <underline>&gt;</underline> 50% at the site of the in-stent lesion; reference diameter between 2.5 mm and 4.0 mm; extension of the lesion <underline>&lt;</underline> 25 mm; and angiographic success (residual stenosis &lt; 50%) immediately after balloon angioplasty. Patients with the following characteristics were excluded from the study: significant left ventricular dysfunction (ejection fraction &lt; 30%); recent acute myocardial infarction (&lt; 72h); evidence of thrombi on angiography; presence of multiple lesions in the target vessel; and previous thoracic radiotherapy. During the process of inclusion, those who did not meet the angiographic criterion of success did not receive intracoronary treatment with beta radiation, but were not excluded from the records. All patients were previously informed about the characteristics of the procedure and signed a written informed consent prior to inclusion.</p>
      <p>All patients received acetylsalicylic acid (325 mg/day) one day before the procedure. Intravenous heparin (100 UI/kg) was administered before the intervention to keep the activated coagulation time &gt; 300 seconds. The therapeutic regimen after the intervention consisted of acetylsalicylic acid and thienopyridinic derivatives (ticlopidine: 500 mg/day or clopidogrel: 75 mg/day) for at least 4 months.</p>
      <p>Prior to intervention, the extension and severity of the lesion, and the luminal diameter in the proximal and distal segments of reference were documented on angiography (<underline>&gt;</underline> 2 projections).</p>
      <p>The Beta-Cath system<sup>TM</sup> available at our facility (Novoste Corp., Norcross, Georgia, USA) consists of a series of 16 independent, radiopaque, cylindrical seeds containing a pure beta strontium/yttrium 90 (<sup>90</sup>Sr/<sup>90</sup>Y) emitter, limited by 2 radiopaque gold markers positioned 40 mm apart, constituting the extension of the source. The catheter's profile is 5 French and the source system is not centralized. The release of the dose occurs 2 mm from the source, being adapted to the diameter of the vessel <sup>15</sup>.</p>
      <p>After balloon catheter angioplasty, intracoronary ultrasound with previous intracoronary administration of isosorbide dinitrate (0.2 mg) was performed. Then, the beta-rail<sup>TM</sup> delivery catheter premounted on a guidewire was advanced and placed equidistantly from the center of the injured segment, with proximal and distal margins of at least 7 mm, through the angiographic vision of the markers of the source (40 mm). After removing the guidewire, the source was hydraulically transported to the distal portion of the delivery catheter, and its position was always angiographically documented. Immediately after finishing the radiation time calculated by the oncologist (<xref ref-type="table" rid="en_21167t1-body2">tab. I</xref>), the source was withdrawn and the beta-rail<sup>TM</sup> delivery catheter was removed. Angiographic assessment in the same orthogonal projections and intracoronary ultrasound were repeated, thus finishing the intervention.</p>
      <p content-type="asset">
        <table-wrap id="en_21167t1-body2">
          <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gt01-en.jpg"/></table-wrap>
      </p>
      <p>Angiographic success was defined as the presence of residual stenosis &lt; 50%, with no technical intercurrence during the radiation process. The success of brachytherapy was characterized by the complete delivery (&gt; 90%) of the established radiation dose. Clinical success was defined as absence of major cardiac events [death, acute myocardial infarction documented according to electrocardiographic and enzymatic criteria (CK-MB &gt; 10-13 U/L or &gt; 5% of the CK activity, or elevation in troponin T-I, or both), and revascularization of the target vessel] during hospitalization. Success of the procedure after brachytherapy was defined as the association of the preceding 3 successes.</p>
      <p>Analysis through quantitative coronary angiography was performed with the off-line method using the QCA-CMS system<sup>&#226;</sup> version 5.1 (MEDIS - Medical Imaging Systems Inc. - AJ Leiden, The Netherlands) in the hemodynamic data and analyses laboratory of our institution. All angiographies were performed after previous intracoronary administration of nitrate, calculating the minimum luminal diameter, the percentage of stenosis (%DS), and the reference diameter. The acute luminal gain was determined by the subtraction of the initial minimum luminal diameter from the minimum luminal diameter after treatment, and the late loss was calculated by the subtraction of the late minimum luminal diameter from the minimum luminal diameter after treatment. Angiographically, the definition of aneurysm was based on a 25% increase in the luminal diameter of the segment treated compared with the luminal diameter of the adjacent segments of reference <sup>16</sup>.</p>
      <p>Still in regard to the minimum luminal diameter, the following parameters were assessed: 1) in-stent minimum luminal diameter, comprising the target segment and the distal and proximal margins of the lesion; 2) intrasegmentary minimum luminal diameter, comprising the injured segment located between the proximal and distal marks of the balloon. Other parameters assessed were the irradiated segment limited by the proximal and distal marks of the radiation catheter, and the segment of the vessel limited by 2 anatomic references (branches), in which the target segment, the injured segment, and the irradiated segment were included. This classification has been frequently used in other clinical studies <sup>17</sup> (<xref ref-type="fig" rid="figura1-body2">fig. 1</xref>).</p>
      <fig id="figura1-body2">
        <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gf01-en.jpg"/></fig>
      <p>Intracoronary ultrasound was routinely performed before the intervention after balloon catheter angioplasty, after brachytherapy, and in late follow-up. The studies were performed with the CVIS system (Boston Scientific Corp., Maple Grove, MN, USA) incorporating a 30-MHz transducer with a rotation of 1800 rpm. For obtaining the sequence of images, the transducer of the ultrasound was pulled by an automated device at a velocity of 0.5 mm/s. The 3-dimensional reconstruction of the image was processed with a computed system (IndecSystems, Mountain View, CA, USA).</p>
      <p>The volumetric analyses were calculated based on the formula of Simpson: Volume =S total area of the vessel, identified by the external elastic membrane, stent, plaque (external elastic membrane &#150; stent), neointimal hyperplasia (NIH), and lumen. To assess the volumetric changes in each element of the vessel at 6 months, the value of each measure was calculated as delta (Dvolume), resulting from the difference between the volumetric values obtained in late follow-up and after the intervention. Similarly, the percentage of volumetric obstruction was calculated [% of obstruction = (NIH volume/stent volume) x 100] for the 3 periods assessed (pre-, postintervention, and at 6 months) <sup>17,18</sup>. On intracoronary ultrasound, aneurysm formation was defined as a 50% increase in the maximum luminal area in the place treated compared with the luminal area in the normal segment of reference<sup>16</sup>.</p>
      <p>Incomplete position of the stent was defined as the presence of 1 or more rods of the stent clearly separated from the wall of the vessel, with evident blood flow behind the rod on ultrasonography <sup>19,20</sup>.</p>
      <p>The occurrence of a defect in the target vessel (DTV) [death, acute myocardial infarction, restenosis according to the binary criterion (lesion &gt; 50%), and revascularization of the target vessel] and the percentage of volumetric obstruction 180 days after brachytherapy were assessed.</p>
      <p>The statistical analysis was performed using SPSS software, version 8.0 (SPSS Inc, Chicago, Illinois, USA). The continuous variables were expressed as means and standard deviation, while the categorical variables were presented as absolute frequencies and percentages. The categorical variables were compared using the chi-square test with continuity correction, or the Fisher exact test, when appropriate. The continuous variables were compared using the Student <italic>t</italic> test with correction using the Welch test, when necessary. Measures without a normal distribution were analyzed using the nonparametric Mann-Whitney test. The significance level adopted was P <underline>&lt;</underline> 0.05. The correlations between the changes in continuous variables were performed with the Pearson correlation test.</p>
      <p>
        <bold>Results</bold>
      </p>
      <p>The clinical and angiographic characteristics of the 30 patients studied are shown in <xref ref-type="table" rid="en_21167t2-body2">table II</xref>. Ten (33%) patients had diabetes mellitus, 44% had stable angina, 4 (13%) had already undergone more than 1 intervention for the treatment of in-stent restenosis, and the mean time since the last intervention was 7.3&#177;2.3 months. Complex lesions predominated as follows: 60% were diffuse, 17% were proliferative, 17% were focal, and 6% were occlusions <sup>3</sup>.</p>
      <p content-type="asset">
        <table-wrap id="en_21167t2-body2">
          <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gt02-en.jpg"/></table-wrap>
      </p>
      <p>Balloon catheter angioplasty was performed in all in-stent lesions. In 1 of the procedures, rotational atherectomy was performed prior to balloon dilation. In our study, no case of residual stenosis &gt; 50% was observed immediately after the procedure. One type A dissection (nonflow-limiting) was evidenced, but required no additional treatment. In regard to brachytherapy, it was used in 100% of the patients, with no electrocardiographic alterations suggestive of myocardial ischemia during the procedure. A 40-mm extension source was used, with a mean radiation dose of 20.7&#177;2.3 Gy applied for 3.8&#177;2.1 minutes.</p>
      <p>The extensions of the target segment and the injured segment were 18.6&#177;4.1 mm and 23.3&#177;3.8 mm, respectively. The in-stent minimum luminal diameter and the intrasegmentary diameter significantly increased after the intervention (both P &lt; 0.0001), resulting in acute luminal gains of 0.91&#177;0.41 mm and 0.85&#177;0.40 mm, respectively (<xref ref-type="table" rid="tabela3-body2">tab. III</xref>). At 6 months, angiographic follow-up was performed in all cases. The in-stent minimum luminal diameter decreased nonsignificantly (1.98&#177;0.30 mm to 1.84&#177;0.39 mm at 6 months; P = 0.13), associated with a late loss of 0.14&#177;0.18 mm. The intrasegmentary minimum luminal diameter was significantly smaller than the in-stent diameter at 6 months of treatment (1.55&#177;0.40 mm versus 1.84&#177;0.39 mm; P=0.008), associated with a greater late intrasegmentary loss (0.40&#177;0.29 mm versus 0.14&#177;0.18 mm; P=0.0001). Five cases of angiographic restenosis (17%) were observed in late follow-up. One patient had restenosis in the distal extremity of the stent; another had 2 restenotic lesions (in-stent and in its distal extremity); another third patient had restenosis in the body of the endoprosthesis. Two cases had stenotic lesions in the proximal extremity of the irradiated segment.</p>
      <table-wrap id="tabela3-body2">
        <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gt03-en.jpg"/></table-wrap>
      <p>Intracoronary ultrasound was performed in 87% (26/30) of the patients immediately after the intervention and at 180 days of late follow-up. At 6 months, the neointimal tissue volume increased slightly (DNIH = +6.75&#177;14.3 mm<sup>3</sup>; P = 0.19), and a nonsignificant reduction in the volume of the in-stent lumen was observed (Dlumen = -10.38&#177;15.7 mm<sup>3</sup>; P = 0.18) (<xref ref-type="table" rid="en_21167t4-body2">tab. IV</xref>). A quantitative increase both in the volume of the vessel and in the plaque was observed at 6 months, without reaching statistical significance. The percentage of volumetric obstruction was reduced from 61.1&#177;8.1% to 26.8&#177;7.2% after the intervention (P &lt; 0.0001), but increased to 30.5&#177;8.0% with 6 months of clinical follow-up (D% obstruction = +4.7&#177;7.5%; P = 0.09). Neither aneurysms, nor late incomplete apposition of the stents was observed.</p>
      <p content-type="asset">
        <table-wrap id="en_21167t4-body2">
          <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gt04-en.jpg"/></table-wrap>
      </p>
      <p>At 6 months, the volume of the vessel showed a positive correlation with the changes in the volume of plaque (r = 0.963; P = 0.01).</p>
      <p>Neither major cardiac events, nor cases of subacute thrombosis, occurred during the hospitalization period (48.8&#177;6.2 h). Of the 30 cases analyzed on late clinical follow-up, 1 (3%) had late thrombosis (46 days after intervention), which evolved with non-Q-wave acute myocardial infarction, and 5 had revascularization of the target vessel (17%), of which 60% (3/5 cases) were performed through a percutaneous route. The total percentage of defect in the target vessel in this series was 20%, resulting in an event-free survival of 80% at 6 months of clinical evolution (<xref ref-type="table" rid="tabela5-body2">tab. V</xref>).</p>
      <table-wrap id="tabela5-body2">
        <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gt05-en.jpg"/></table-wrap>
      <p>
        <bold>Discussion</bold>
      </p>
      <p>In our study, the use of intracoronary brachytherapy with the Beta-Cath system suggests that it is a technically safe and feasible procedure, with favorable results in the management of in-stent restenosis <sup>21,22</sup> at 6 months of clinical follow-up (<xref ref-type="fig" rid="figura2-body2">fig. 2</xref>).</p>
      <fig id="figura2-body2">
        <graphic xlink:href="1678-4170-abc-83-01-0057-00006-gf02-en.jpg"/></fig>
      <p>Diffuse and proliferative restenoses, which represented 77% of our cases, have the worst prognosis after percutaneous management. In the study by Mehran et al <sup>3</sup>, those cases had a new relapse in 50-80% of the cases after balloon catheter angioplasty, in contrast with our results, in which the relapse rate 6 months after brachytherapy was 17%. This suggests that brachytherapy is better than the conventional treatment with the balloon, confirming the results of previous investigations <sup>21-23</sup>.</p>
      <p>The pre-established radiation dose was totally delivered in all lesions. All patients received antiplatelet therapy (acetylsalicylic acid indefinitely) and thienopyridinic derivatives for at least 4 months; no major cardiac events occurred during the first month. One (3%) late thrombotic occlusion was observed, manifested as non-Q-wave acute myocardial infarction, a percentage lower than that reported in the WRIST, Long-WRIST, SVG-WRIST, GAMMA-1, and BETA-WRIST studies (9.1%, 5 months after the procedure) <sup>24</sup> and similar to that reported in the WRIST-PLUS <sup>26</sup> and INHIBIT studies <sup>26</sup>. Only 1 nonflow-limiting dissection was documented at the end of the procedure; although it did not require additional treatment, it later was associated with 1 of the restenoses observed (distal extremity of the stent). The impact of nonflow-limiting dissections on the prognosis of patients undergoing brachytherapy is still unknown. In 2 series of 16 patients each, the presence of acute dissection after balloon angioplasty and beta radiation persisted in approximately 50% of the patients after 6 months of clinical follow-up <sup>27,28</sup>, and it showed no association with the recurrence of angina or any other clinical event in particular <sup>28</sup>.</p>
      <p>In regard to the clinical events here documented, our results were similar to those found in previous studies using intracoronary beta radiation, in which the incidence of major cardiac events ranged from 18% to 33% as follows: START (18%) <sup>29</sup>, INHIBIT (22%) <sup>26</sup>, and BETA-WRIST (33%) <sup>30</sup>. Similarly, the restenosis rate in these studies ranged from 15% to 29% <sup>22,26,30</sup>.</p>
      <p>Comparing the late loss in the segments angiographically defined, the intrasegmentary minimum luminal diameter showed a statistically greater reduction than the in-stent minimum luminal diameter, due to the lesion caused by the balloon in the segments adjacent to the stent. This phenomenon, reported as "geographical loss," observed in 13% of new cases, is mainly characterized by inadequate radiation in the injured segment <sup>31</sup>. Theoretically, this condition occurs when the extremities of the irradiated segment are damaged, in which, by definition, the dose emitted is very low. In a retrospective analysis <sup>31</sup> of 50 consecutive patients treated with beta radiation after balloon catheter angioplasty or stent, the incidence of that phenomenon was 32%.</p>
      <p>The volumetric analysis on intracoronary ultrasound showed that the growth of neointimal tissue was mild after 6 months of clinical follow-up, a result similar to that of other studies <sup>32</sup>. The growth of the vessel (+21.4&#177;27.8 mm<sup>3</sup>) observed after 180 days of treatment suggests that intracoronary beta radiation induced a positive remodeling of the arterial wall, characterized by an "accommodative" process of the plaque (correlation of the increase in the D external elastic membrane vs D plaque, r=0.963, P &lt; 0.01), preserving the volume of the in-stent lumen. Experimental data have suggested that radiation has an effect on the remodeling of the vessel, due to the change in cell response in the adventitia layer <sup>33,34</sup>. Positive remodeling, accommodating the neointimal growth after 6 months, has been shown on ultrasonographic analyses <sup>35</sup>, considering that other studies did not report changes in the total area of the vessel or of the plaque behind the stent <sup>27</sup>.</p>
      <p>Compared with gamma radiation, beta radiation has a smaller depth of penetration, minimizing the exposure to radiation for patients and operators, requiring, therefore, less radioprotection. However, the rapid decrease in the dose of beta radiation within 2-5mm of depth is associated with a less homogeneous release of the dose <sup>32</sup>. In addition, the "shield effect" produced by the rods of the stent could be associated with an attenuation in the radiation dose through its rods greater than 15% <sup>36</sup>. Comparing the results on intracoronary ultrasound in 2 large studies <sup>13,15</sup>, beta radiation showed a greater benefit than gamma radiation did in preventing neointimal hyperplasia inside the stent <sup>37,38</sup>.</p>
      <p>Finally, it is worth emphasizing that the Latin-American participation in the development of this innovative therapeutic option in managing stenotic lesions has been paramount. The first clinical experience with radiation in human coronary arteries was reported by Condado et al <sup>39</sup> in Venezuela. Those authors introduced an iridium <sup>192</sup> guide inside a catheter, which was not centralized in the lumen of a vessel, using a manually deployed device. They, therefore, showed that the administration of radiation inside the coronary artery was feasible and safe, although followed by high restenosis rates in that initial experience.</p>
      <p>Our study consisted of an initial series of consecutive cases of in-stent restenosis treated at our facility, with a late clinical follow-up limited to 6 months. Due to the relatively reduced number of patients assessed and to the design of the study (nonrandomized, with no control group, and with the exclusion of more complex cases), the results here reported should not be extrapolated to all cases of this affliction.</p>
      <p>Although the clinical events observed in the late follow-up of our patients did not differ from those reported in the large randomized studies, one cannot say they are clinically equivalent, because our sample size does not allow this conclusion. Independently of the already cited observations, this study provided a satisfactory initial clinical experience with the use of this technique. The patients studied continue to be followed up, and new cases have been progressively incorporated.</p>
      <p>In conclusion, the present study suggests that intracoronary brachytherapy with the Beta-Cath system<sup>TM</sup> after balloon catheter angioplasty is a safe and efficient therapeutic option for patients with in-stent restenosis. Therefore, in cases with clinical and angiographic characteristics similar to those in this study, intracoronary brachytherapy may be considered part of the therapeutic arsenal in the treatment of this affliction. These initial results add to those of previous randomized clinical studies, confirming the safety, feasibility, and pertinence of the method.</p>
      <p>
        <bold>References</bold>
      </p>
      <p>
        <fn id="back10-body2" fn-type="corresp">
          <p>Correspondence to</p>
          <p>Juan Simon Mu&#241;oz</p>
          <p> Instituto Dante Pazzanese de Cardiologia</p>
          <p> Av. Dr. Dante Pazzanese, 500</p>
          <p> Cep 04012-909 S&#227;o Paulo, SP, Brazil</p>
          <p> E-mail: </p>
          <p>
            <email xlink:href="jsmuro@hotmail.com">jsmuro@hotmail.com</email>
          </p>
        </fn>
      </p>
      <p>Received: 4/16/03</p>
      <p>Accepted: 7/6/03</p>
      <p>English version by Stela Maris Costalonga</p>
    </body>
  </sub-article>
</article>
