<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="en" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">MtNnLwv8B5zhrp7gRPZPFzq</article-id>
      <article-id pub-id-type="other">00008</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2003000100008</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(03)08000108</article-id>
      <article-id pub-id-type="doi">10.1590/S0066-782X2003000100008</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Articles</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Assessment of the techniques of blood pressure measurement by health professionals</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Veiga</surname>
            <given-names>Eugenia Velludo</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Nogueira</surname>
            <given-names>Maria Suely</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>C&#225;rnio</surname>
            <given-names>Evelin Capellari</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Marques</surname>
            <given-names>Sueli</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Lavrador</surname>
            <given-names>Marco Aur&#233;lio S.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Moraes</surname>
            <given-names>Suzana Alves de</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Souza</surname>
            <given-names>Luciana A. C.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Lima</surname>
            <given-names>Nereida K. C.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Nobre</surname>
            <given-names>Fernando</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <addr-line>
          <named-content content-type="state">S&#227;o Paulo</named-content>
        </addr-line>
        <institution content-type="orgname">Universidade de S&#227;o Paulo</institution>
        <institution content-type="orgdiv1">Escola de Enfermagem de Ribeir&#227;o Preto </institution>
        <country country="BR">Brazil</country>
      </aff>
      <aff id="aff02">
        <addr-line>
          <named-content content-type="city">Ribeir&#227;o Preto</named-content>
          <named-content content-type="state">S&#227;o Paulo</named-content>
        </addr-line>
        <institution content-type="orgname">Universidade de S&#227;o Paulo</institution>
        <institution content-type="orgdiv1">FM </institution>
        <institution content-type="orgdiv2">Hospital das Cl&#237;nicas de Ribeir&#227;o Preto</institution>
        <country country="BR">Brazil</country>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>01</month>
        <year>2003</year>
      </pub-date>
      <volume>80</volume>
      <issue>1</issue>
      <fpage>89</fpage>
      <lpage>93</lpage>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <abstract>
        <p>OBJECTIVE: To assess blood pressure measurement by health professionals of a public hospital in S&#227;o Paulo State. METHODS: Semi-structured interviews and direct observation were performed with a verification list according to the criteria reported by Perloff et al. One hundred and five health professionals took part in the study. After measuring blood pressure, the level of concordance between the way the procedure was performed and the recommended one was assessed. RESULTS: Nurses and nurse's aides abided by 40% of the recommended procedures for adequate blood pressure measurement. The other categories of health professionals (nursing and medicine teachers, physicians, residents, and nursing students) abided by approximately 70%. CONCLUSION: Permanent educational activities aiming at standardizing blood pressure measurement should be implemented among the different categories of health professionals.</p>
      </abstract>
      <kwd-group xml:lang="en" kwd-group-type="author-generated">
        <kwd>blood pressure</kwd>
        <kwd>blood pressure measurement</kwd>
        <kwd>methods of blood pressure measurement</kwd>
      </kwd-group>
      <pub-date publication-format="electronic" date-type="pub">
        <day>04</day>
        <month>01</month>
        <year>2012</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>
      <bold>ORIGINAL ARTICLE</bold>
    </p>
    <p>
      <bold>Assessment of the techniques of blood pressure measurement by health professionals</bold>
    </p>
    <p>
      <bold>Eugenia Velludo Veiga; Maria Suely Nogueira; Evelin Capellari C&#225;rnio; Sueli Marques; Marco Aur&#233;lio S. Lavrador; Suzana Alves de Moraes; Luciana A. C. Souza; Nereida K. C. Lima; Fernando Nobre</bold>
    </p>
    <p>Escola de Enfermagem de Ribeir&#227;o Preto of USP and Hospital das Cl&#237;nicas de Ribeir&#227;o Preto, FMUSP </p>
    <p>Ribeir&#227;o Preto, SP, Brazil</p>
    <p>
      <xref ref-type="corresp" rid="end">Address to correspondence</xref>
    </p>
    <p>
      <bold>ABSTRACT</bold>
    </p>
    <p><bold>OBJECTIVE: </bold>To assess blood pressure measurement by health professionals of a public hospital in S&#227;o Paulo State. </p>
    <p><bold>METHODS:</bold> Semi-structured interviews and direct observation were performed with a verification list according to the criteria reported by Perloff et al. One hundred and five health professionals took part in the study. After measuring blood pressure, the level of concordance between the way the procedure was performed and the recommended one was assessed. </p>
    <p><bold>RESULTS:</bold> Nurses and nurse's aides abided by 40% of the recommended procedures for adequate blood pressure measurement. The other categories of health professionals (nursing and medicine teachers, physicians, residents, and nursing students) abided by approximately 70%. </p>
    <p><bold>CONCLUSION:</bold> Permanent educational activities aiming at standardizing blood pressure measurement should be implemented among the different categories of health professionals.</p>
    <p><bold>Key words: </bold>blood pressure, blood pressure measurement, methods of blood pressure measurement</p>
    <p>Systemic hypertension is considered one of the major risk factors of cardiovascular morbidity and mortality, accounting for 40% of the cases of early retirement and absenteeism in the workplace <sup>1,2</sup>.</p>
    <p>Precise blood pressure measurement is an essential condition for the diagnosis of hypertension, because blood pressure elevation is usually the first sign of the disease. It is an easy and simple procedure; however, if certain principles are not obeyed, blood pressure measurement will be subjected to several factors of error with significant practical consequences <sup>3</sup>. Therefore, precise blood pressure measurement with the consequent establishment of a correct diagnosis of hypertension is important to determine criteria for the development of that procedure. Those criteria may relate to the environment, the observer, the patient, and the device used <sup>4-7</sup>.</p>
    <p>The literature shows the need for standardizing the criteria for blood pressure measurement. In addition, blood pressure measurement should be performed in a systematic way by health professionals, implying the obtainment of real values of blood pressure, which may determine the adequate management and treatment of hypertension when present <sup>8-12</sup>.</p>
    <p>Because of our involvement in teaching and researching blood pressure measurement at the undergraduate and postgraduate level to nursing and medical students, we felt the need to assess the blood pressure measuring procedure according to the criteria recommended by the American Heart Association in 1993 <sup>6</sup>. We analyzed the daily assessment of blood pressure levels of patients hospitalized or followed up on an outpatient care basis at hospital, and observed mainly the health professionals performing that task.</p>
    <p>This study aimed at assessing blood pressure measurement by the health professionals of a public hospital in S&#227;o Paulo State.</p>
    <p>
      <bold>Methods</bold>
    </p>
    <p>The project was submitted to the Committee on Ethics and Research of the above-cited hospital and was approved. After that, the directors of a nursing and medical schools were required to provide 2 lists as follows: 1) a list of the teachers working in the disciplines of the following units of hospital admission: general medicine, gynecology and obstetrics, surgery, neurology, orthopedics, otorhinolaryngology, and ophthalmology; 2) a list of 4th-grade students of the nursing school in 1996. The administration at the hospital was asked to provide a list of the 2nd-year residents, nurses, and nurse's aides in the above-cited specialties and units, which comprised 662 individuals. Of this population, a random sample of 138 individuals was obtained, corresponding to 20% of each professional category, of whom 33 (24%) did not participate in the study for several reasons, such as vacation, day off, and leave of absence, which resulted in the assessment of 105 individuals.</p>
    <p>A protocol was used for collecting the following data for identification of the individuals: professional category, age in years, sex, and place and year of graduation. The blood pressure measuring procedure was assessed by the following items: interaction with the examinee; patient's position, considering the sitting or lying down position; resting period of 3 to 5 minutes prior to blood pressure measurement; arm position at 45&#176;, at the level of the heart; arm circumference measurement; selection of the inflatable rubber bag according to the arm circumference; cuff placement on a naked arm; adequately visible manometer; identification of the site of the brachial artery; cuff adequately involving the arm; previous determination of the inflation level through palpation; cuff deflation at a rate of 2 to 3 mm Hg/s; 30-second interval between 2 measurements; and position of the metallic cup of the stethoscope over the brachial artery. Through the semi-structured interview and direct observation, the following data were obtained: limb selected for blood pressure measurement; patient's position (sitting, lying down, standing); blood pressure value in mm Hg obtained during the first and second measurements, if the latter occurred; the type of sphygmomanometer used in daily practice: aneroid or mercury column; and frequency of calibration of the devices.</p>
    <p>Data were collected from May 1996 to December 1997 by 5 researchers previously trained in standardizing blood pressure measurement and completing the questionnaire.</p>
    <p>The individuals participating in the study were informed about the objectives of the study, the reason why they were taking part in it, and they had to provide a written informed consent to take part in the study.</p>
    <p>The observation and interview occurred at the workplace of each participant, with the previous election of the patient to be examined. Then, this patient was asked to have his blood pressure and arm circumference measured. The professional observed did not know about this.</p>
    <p>Blood pressure was measured in an appropriate place with all required resources available for the professionals in the study, such as mercury column and aneroid sphygmomanometers, cuffs of different widths, stethoscope, measuring tape, and the option of a silent place if the professionals found necessary to have one for the procedure.</p>
    <p>
      <bold>Results</bold>
    </p>
    <p>One hundred and five individuals of different professional categories took part in this study (<xref ref-type="table" rid="tabela1">tab. I</xref>) and their ages ranged from 20 to 50 (mean of 33.6&#177;10.1) years. In regard to sex, 41 (39%) were males.</p>
    <table-wrap id="tabela1">
      <label>Table II</label>
      <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt01.jpg"/></table-wrap>
    <p content-type="asset">
      <table-wrap id="t2">
        <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt02.jpg"/></table-wrap>
    </p>
    <p>Of the graduated individuals, 47.8% had concluded their courses 1 to 5 years before (<xref ref-type="table" rid="t3">tab. III</xref>).</p>
    <p content-type="asset">
      <table-wrap id="t3">
        <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt03.jpg"/></table-wrap>
    </p>
    <p>Of other important factors for adequate blood pressure measurement, some variables, such as the number of measurements taken, preferred final digits, type of device used for measurement, and calibration of the devices, were also assessed in the study through direct observation and interview, after observing blood pressure measurement, using the verification list.</p>
    <p>In regard to the number of measurements taken, most individuals (66.7%) identified blood pressure values in a single measurement; 78% of the observers reported not having adequate cuffs for their professional practice. <xref ref-type="table" rid="tabela4">Table IV</xref> shows the distribution of the final digits recorded for systolic and diastolic blood pressure values, the preference for zero as the final digit in systolic blood pressure values in 77.1%, and in diastolic blood pressure values in 74.3% of the measurements. In regard to the final digits, 17.2% of the individuals recorded digits between 2 and 8 for systolic blood pressure, and 14.4% for diastolic blood pressure, while 5.7% recorded odd final digits (from 1 to 9) for systolic blood pressure and 11.4% for diastolic blood pressure.</p>
    <table-wrap id="tabela4">
      <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt04.jpg"/></table-wrap>
    <p><xref ref-type="table" rid="tabela5">Table V</xref> shows the distribution of the number and percentages of the types of devices reported as routinely used by the participants.</p>
    <table-wrap id="tabela5">
      <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt05.jpg"/></table-wrap>
    <p>In regard to calibration of the devices, <xref ref-type="table" rid="tabela6">table VI</xref> shows the frequency reported as used by the population evaluated.</p>
    <table-wrap id="tabela6">
      <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt06.jpg"/></table-wrap>
    <p>Blood pressure measurement in this study comprised 16 steps described according to the recommendations of Perloff et al <sup>6</sup>. In regard to interaction with the patient, the explanation of the procedure to the patient was the most frequently performed step (97.1%), while the selection of the adequate width of the cuff was performed only by 6.7% of the sample. Some of the different health professionals studied were observed not to perform several steps of the procedure.</p>
    <p>Two categories of health professionals, nurses and nurse's aides, performed less than 50% of the steps recommended for the procedure, unlike the other professionals studied, the nursing and medicine teachers, the residents, and the nursing students, who followed approximately 70% of the steps.</p>
    <p><xref ref-type="table" rid="t7">Table VII</xref> shows the numbers and percentages of the different professional categories studied and the steps followed during blood pressure measurement. It is evident that only a minority of the professionals studied performed some important steps, such as the selection of the adequate cuff, the measurement of the arm circumference, and the 30-second intervals between 2 measurements.</p>
    <p content-type="asset">
      <table-wrap id="t7">
        <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt07.jpg"/></table-wrap>
    </p>
    <p>
      <bold>Discussion</bold>
    </p>
    <p>This study aimed at assessing the way blood pressure was measured by different health professionals at a hospital, considering the steps reported in the literature and defined in the methodology of this study. Several researchers have tried to identify whether the health professionals have been performing this procedure adequately, because it is directly related to the evaluation of a vital parameter <sup>3,13-16</sup>. In the assisting practice among different professionals and at different places, blood pressure measurement is not correctly taken, which may compromise the values obtained, and, consequently, the diagnosis, treatment, and control of hypertension. Recently, studies carried out in S&#227;o Paulo <sup>13,14</sup> have reported that most nurses ignore the meaning of blood pressure measurements. Other studies have also shown irregularities in this procedure <sup>15,16</sup>.</p>
    <p>It is worth stressing the importance of this procedure among professionals who work at different clinics, in epidemiological research, at restricted units, or at outpatient care units. The number of studies reporting errors involving blood pressure measurement has increased lately, and they have been attributed to the devices, the examiners, and the examinees <sup>11</sup>. In addition to the diversity of professionals studied, most of them had graduated 1 to 5 years before. Therefore, we can infer that graduation courses may not be adequately preparing the professionals for performing this specific procedure. The formation of the nurse's aides stands out for its practical and fundamental approach, because they are specifically oriented to hospital practice.</p>
    <p>This study analyzed a set of 16 steps for blood pressure measurement according to Perloff et al <sup>6</sup>.</p>
    <p>In regard to indirect blood pressure measurement, the least performed step among the individuals studied was the selection of the adequate cuff, because only 7% of the individuals checked on that aspect.</p>
    <p>It is clear that several steps have not been performed during blood pressure measurement, a fact that was observed in all professional categories studied. If the importance of this fact is considered in obtaining reliable blood pressure values, the severity of these findings may be recognized, and they may be directly impairing the blood pressure values obtained. In the literature, several authors have reported the importance of careful blood pressure measurement, because the values obtained ensure the early detection of hypertension, its correct diagnosis and control, in addition to precisely defining its treatment <sup>3,6,8</sup>.</p>
    <p>When asked, 78% of the individuals assessed reported not having cuffs of different dimensions available for blood pressure measurement. The width of the cuff influences the blood pressure values obtained; blood pressure is underestimated when larger cuffs are used and is overestimated when smaller cuffs are used. According to the American Heart Association, the width of the rubber bag should be approximately 40% of the arm circumference <sup>17</sup>. Some studies have reported these differences of under- and overestimation in individuals of different age groups and in Brazilian pregnant women <sup>18-21</sup>. The rules for correction are very limited, because they cannot correct vascular reactivity and arm circumferences &lt; 20 and &gt; 40 cm, which are frequently found in elderly or undernourished adults and in obese individuals. The question of thin arms concerns researchers even more because it makes the early identification of high blood pressure values difficult and may compromise the identification of alterations that do not influence the health status and the quality of life of the individuals <sup>18-21</sup>. If health professionals are not assessing arm circumference at the time of blood pressure measurement, they are imposing important errors on the values obtained.</p>
    <p>In regard to the intervals between measurements, 26.7% of the interviewees waited at least 30 seconds. Palpation of the radial pulse prior to cuff inflation is extremely important, mainly in the elderly, because of the possibility of calcification of the arteries and the auscultatory gap. Of the individuals assessed, only 53.3% deflated the cuff at a rate between 2 and 3 mmHg/s, as recommended <sup>8,12</sup>. Cuff deflation at a more rapid velocity makes it difficult to precisely establish both systolic and diastolic blood pressure values <sup>6,9,14</sup>. The adequate position of the upper limb and maintenance of the individual at rest for a period of 3 to 5 minutes prior to blood pressure measurement were steps performed by 64.8% and 66.7% of the individuals assessed, respectively. Previous rest for the above-cited period and maintenance of the upper limb at the level of the heart are fundamental procedures for obtainment of measurements that actually express blood pressure behavior <sup>9,10,14,22</sup>.</p>
    <p>The acts of adequately involving the arm with the cuff and locating the brachial artery at the moment of blood pressure measurement were performed for approximately 70% of the individuals studied, representing a more acceptable and equally important percentage. The adequate placements of the stethoscope and manometer to properly visualize blood pressure values were procedures performed by 81% to 82.9% of the individuals, respectively; interaction with the patient was observed in 91.4% of the sample studied. Blood pressure was measured with the naked arm by 97.1% of the individuals. This fact may play an important role, mainly because clothing may interfere with the arm width, causing an error in measurement.</p>
    <p>Another fact that influences the obtainment of correct blood pressure values is the number of measurements. One single measurement was taken by 66.7% of the participants, who considered this correct.</p>
    <p>In regard to the blood pressure values obtained, zero was recorded as the final digit for systolic blood pressure by 77.1% of the participants and for diastolic blood pressure by 74.3%. Considering the frequency of the steps followed by the different professionals, nurses and the nurse's aides were those who less frequently followed the steps, which had been ideally proposed to correct blood pressure measurement. This is very preoccupying, because these professional categories act improperly on daily blood pressure measurement.</p>
    <p>In conclusion, the need to improve observance of the steps of blood pressure measurement was identified in all professional categories studied. Greater attention should be paid to the factors of errors closely related to obtainment of blood pressure values, such as environment, the individual, the observer, and the device. Learning and teaching strategies regarding blood pressure measurement are urgently required, such as updating courses, investments in continuing education, and the insertion of specific contents in undergraduate and postgraduate courses. The multidisciplinary approach involving early detection, treatment, and control of hypertension requires that blood pressure measurement be effectively performed for the obtainment of reliable data and precise diagnoses.</p>
    <p>
      <fn id="end" fn-type="corresp">
        <label>
          <bold>Address to correspondence</bold>
        </label>
        <p> Eugenia Velludo Veiga, Campus da USP, Escola de Enfermagem de Ribeir&#227;o Preto </p>
        <p> Av. Bandeirantes, 3900 </p>
        <p> 14040-902, Ribeir&#227;o Preto, SP, Brazil </p>
        <p> E-mail: </p>
        <p>
          <email xlink:href="evveiga@eerp.usp.br">evveiga@eerp.usp.br</email>
        </p>
      </fn>
    </p>
    <p>English version by Stela Maris C. e Gandour</p>
  </body>
  <back>
    <ref-list>
      <ref id="B1">
        <label>1</label>
        <mixed-citation>1. Minist&#233;rio da Sa&#250;de - Brasil. Secretaria de Assist&#234;ncia &#224; Sa&#250;de. Coordena&#231;&#227;o de Doen&#231;as Cardiovasculares. Controle da Hipertens&#227;o Arterial: Uma proposta de integra&#231;&#227;o ensino-servi&#231;o. Rio de Janeiro: CDCV/Nunetes, 1993: 232p.</mixed-citation>
        <element-citation publication-type="book">
          <source>Controle da Hipertens&#227;o Arterial: Uma proposta de integra&#231;&#227;o ensino-servi&#231;o</source>
          <date>
            <year>1993</year>
          </date>
          <fpage>232</fpage>
        </element-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Spritzer N. Epidemiologia da hipertens&#227;o arterial sist&#234;mica.    Medicina 1996; 29: 199-213.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Epidemiologia da hipertens&#227;o arterial sist&#234;mica</article-title>
          <source>Medicina</source>
          <date>
            <year>1996</year>
          </date>
          <fpage>199</fpage>
          <lpage>213</lpage>
          <volume>29</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Spritzer</surname>
              <given-names>N</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. Pierin AMG, Gomes MAM. A medida da press&#227;o arterial em casa.    Revista da Sociedade Brasileira de Hipertens&#227;o 1998; 1: 36.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>A medida da press&#227;o arterial em casa</article-title>
          <source>Revista da Sociedade Brasileira de Hipertens&#227;o</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>36</fpage>
          <volume>1</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Pierin</surname>
              <given-names>AMG</given-names>
            </name>
            <name>
              <surname>Gomes</surname>
              <given-names>MAM</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Lehane A, O'Malley K, O'Brien ET. Reporting of blood pressure data    in medical journals. Br Med J 1980; 281: 1603-4.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Reporting of blood pressure data in medical journals</article-title>
          <source>Br Med J</source>
          <date>
            <year>1980</year>
          </date>
          <fpage>1603</fpage>
          <lpage>4</lpage>
          <volume>281</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Lehane</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>O'Malley</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>O'Brien</surname>
              <given-names>ET</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. Roche V, O'Malley K o'Brien ET. How "scientific" is blood pressure    measurement in leading medical Journals? J Hypertens 1990; 8: 21167-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>How "scientific" is blood pressure measurement in leading medical Journals?</article-title>
          <source>J Hypertens</source>
          <date>
            <year>1990</year>
          </date>
          <fpage>21167</fpage>
          <lpage>8</lpage>
          <volume>8</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Roche</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>O'Malley</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>o'Brien</surname>
              <given-names>ET</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B6">
        <mixed-citation>6. Perloff D, Grim C, Flack J, et al. Human blood pressure determination    by sphygmomanometry. Circulation 1993; 88: 2460-70.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Human blood pressure determination by sphygmomanometry</article-title>
          <source>Circulation</source>
          <date>
            <year>1993</year>
          </date>
          <fpage>2460</fpage>
          <lpage>70</lpage>
          <volume>88</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Perloff</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Grim</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Flack</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B7">
        <mixed-citation>7. Petrie JC, O'Brien ET, Litller WA, Swiet M. Recommendations on blood    pressure measurement. Br Med J 1986; 293: 611-5.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Recommendations on blood pressure measurement</article-title>
          <source>Br Med J</source>
          <date>
            <year>1986</year>
          </date>
          <fpage>611</fpage>
          <lpage>5</lpage>
          <volume>293</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Petrie</surname>
              <given-names>JC</given-names>
            </name>
            <name>
              <surname>O'Brien</surname>
              <given-names>ET</given-names>
            </name>
            <name>
              <surname>Litller</surname>
              <given-names>WA</given-names>
            </name>
            <name>
              <surname>Swiet</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B8">
        <mixed-citation>8. II Consenso Brasileiro para o tratamento da Hipertens&#227;o Arterial.    Arq Bras Cardiol 1994: 16(supl. 2): S257-68.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>II Consenso Brasileiro para o tratamento da Hipertens&#227;o Arterial</article-title>
          <source>Arq Bras Cardiol</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>257</fpage>
          <lpage>68</lpage>
          <volume>16</volume>
        </element-citation>
      </ref>
      <ref id="B9">
        <mixed-citation>9. III Consenso Brasileiro para o tratamento da Hipertens&#227;o Arterial.    Rev Bras Hipertens 1999: 67-106.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>III Consenso Brasileiro para o tratamento da Hipertens&#227;o Arterial</article-title>
          <source>Rev Bras Hipertens</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>67</fpage>
          <lpage>106</lpage>
        </element-citation>
      </ref>
      <ref id="B10">
        <mixed-citation>10. VI Joint National Committee on Prevention Detection, Evaluation and    treatment of high blood pressure. Arch Int Med 1997; 157: 2413-45.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>VI Joint National Committee on Prevention Detection, Evaluation and treatment of high blood pressure</article-title>
          <source>Arch Int Med</source>
          <date>
            <year>1997</year>
          </date>
          <fpage>2413</fpage>
          <lpage>45</lpage>
          <volume>157</volume>
        </element-citation>
      </ref>
      <ref id="B11">
        <mixed-citation>11. Holanda HEM, Mion JD, Pierin AMG. Medida da press&#227;o arterial:    crit&#233;rios empregados em artigos cient&#237;ficos de peri&#243;dicos    brasileiros. Arq Bras Cardiol 1997; 68: 433-6.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Medida da press&#227;o arterial: crit&#233;rios empregados em artigos cient&#237;ficos de peri&#243;dicos brasileiros</article-title>
          <source>Arq Bras Cardiol</source>
          <date>
            <year>1997</year>
          </date>
          <fpage>433</fpage>
          <lpage>6</lpage>
          <volume>68</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Holanda</surname>
              <given-names>HEM</given-names>
            </name>
            <name>
              <surname>Mion</surname>
              <given-names>JD</given-names>
            </name>
            <name>
              <surname>Pierin</surname>
              <given-names>AMG</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B12">
        <mixed-citation>12. Mion Jr D, Pierin A, Krasilcic S, et al. Diagn&#243;stico da hipertens&#227;o    arterial. Medicina 1996; 29: 193-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Diagn&#243;stico da hipertens&#227;o arterial</article-title>
          <source>Medicina</source>
          <date>
            <year>1996</year>
          </date>
          <fpage>193</fpage>
          <lpage>8</lpage>
          <volume>29</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Mion Jr</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Pierin</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Krasilcic</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B13">
        <mixed-citation>13. Ara&#250;jo TL, Arcuri EAM. Influ&#234;ncia de fatores an&#225;tomo    fisiol&#243;gicos na medida indireta da press&#227;o arterial: identifica&#231;&#227;o    do conhecimento dos enfermeiros. Rev Latino-Am Enfermagem 1998; 6: 21-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Influ&#234;ncia de fatores an&#225;tomo fisiol&#243;gicos na medida indireta da press&#227;o arterial: identifica&#231;&#227;o do conhecimento dos enfermeiros</article-title>
          <source>Rev Latino-Am Enfermagem</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>21</fpage>
          <lpage>9</lpage>
          <volume>6</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Ara&#250;jo</surname>
              <given-names>TL</given-names>
            </name>
            <name>
              <surname>Arcuri</surname>
              <given-names>EAM</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B14">
        <mixed-citation>14. Ara&#250;jo TL, Arcuri EAM, Martins E. Instrumenta&#231;&#227;o    na medida da press&#227;o arterial: aspectos hist&#243;ricos, conceituais    e fontes de erro. Rev Esc Enf USP 1998; 32: 33-41.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Instrumenta&#231;&#227;o na medida da press&#227;o arterial: aspectos hist&#243;ricos, conceituais e fontes de erro</article-title>
          <source>Rev Esc Enf USP</source>
          <date>
            <year>1998</year>
          </date>
          <fpage>33</fpage>
          <lpage>41</lpage>
          <volume>32</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Ara&#250;jo</surname>
              <given-names>TL</given-names>
            </name>
            <name>
              <surname>Arcuri</surname>
              <given-names>EAM</given-names>
            </name>
            <name>
              <surname>Martins</surname>
              <given-names>E</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B15">
        <mixed-citation>15. Santos SB, Jesus CAC, Kamada I, Jesus PC, Junqueira Jr LF. Avalia&#231;&#227;o    da t&#233;cnica da medida da press&#227;o arterial. II Congresso de Inicia&#231;&#227;o    Cient&#237;fica da UnB, Bras&#237;lia, DF, 1996; (resumo): 84.</mixed-citation>
        <element-citation publication-type="confproc">
          <source>resumo</source>
          <date>
            <year>1996</year>
          </date>
          <person-group person-group-type="author">
            <name>
              <surname>Santos</surname>
              <given-names>SB</given-names>
            </name>
            <name>
              <surname>Jesus</surname>
              <given-names>CAC</given-names>
            </name>
            <name>
              <surname>Kamada</surname>
              <given-names>I</given-names>
            </name>
            <name>
              <surname>Jesus</surname>
              <given-names>PC</given-names>
            </name>
            <name>
              <surname>Junqueira Jr</surname>
              <given-names>LF</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B16">
        <mixed-citation>16. Carvalho JS, Jesus CAC, Kamada I, Jesus PC, Junqueira Jr. LF. Avalia&#231;&#227;o    do conhecimento te&#243;rico que fundamenta a medida da press&#227;o arterial.    II Congresso de Inicia&#231;&#227;o Cient&#237;fica da UnB, Bras&#237;lia,    DF, 1996; (resumo): 83.</mixed-citation>
        <element-citation publication-type="confproc">
          <source>resumo</source>
          <date>
            <year>1996</year>
          </date>
          <person-group person-group-type="author">
            <name>
              <surname>Carvalho</surname>
              <given-names>JS</given-names>
            </name>
            <name>
              <surname>Jesus</surname>
              <given-names>CAC</given-names>
            </name>
            <name>
              <surname>Kamada</surname>
              <given-names>I</given-names>
            </name>
            <name>
              <surname>Jesus</surname>
              <given-names>PC</given-names>
            </name>
            <name>
              <surname>Junqueira Jr.</surname>
              <given-names>LF</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B17">
        <mixed-citation>17. Fr&#246;hlich ED, Grim C, Labarthe DR, et al. Recommendations for    human blood pressure determination by sphygmomanometers Hypertension. Circulation    1988; 11(supp 1): 210-22.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Recommendations for human blood pressure determination by sphygmomanometers Hypertension</article-title>
          <source>Circulation</source>
          <date>
            <year>1988</year>
          </date>
          <fpage>210</fpage>
          <lpage>22</lpage>
          <issue>supp 1</issue>
          <volume>11</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Fr&#246;hlich</surname>
              <given-names>ED</given-names>
            </name>
            <name>
              <surname>Grim</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Labarthe</surname>
              <given-names>DR</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B18">
        <mixed-citation>18. Oliveira SMJV. Influ&#234;ncia da largura do manguito na medida    da press&#227;o arterial no ciclo gr&#225;vido-puerperal. (Tese Doutorado).    S&#227;o Paulo: Escola de Enfermagem, Universidade de S&#227;o Paulo, 1997:    145p.</mixed-citation>
        <element-citation publication-type="thesis">
          <source>Influ&#234;ncia da largura do manguito na medida da press&#227;o arterial no ciclo gr&#225;vido-puerperal</source>
          <date>
            <year>1997</year>
          </date>
          <fpage>145</fpage>
          <person-group person-group-type="author">
            <name>
              <surname>Oliveira</surname>
              <given-names>SMJV</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B19">
        <mixed-citation>19. Veiga EV. Medida indireta da press&#227;o arterial em fun&#231;&#227;o    da largura do manguito, em escolares de 6 a 10 anos de idade. (Tese Doutorado).    Ribeir&#227;o Preto: Escola de Enfermagem de Ribeir&#227;o Preto, USP, 1995:    162p.</mixed-citation>
        <element-citation publication-type="thesis">
          <source>Medida indireta da press&#227;o arterial em fun&#231;&#227;o da largura do manguito, em escolares de 6 a 10 anos de idade</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>162</fpage>
          <person-group person-group-type="author">
            <name>
              <surname>Veiga</surname>
              <given-names>EV</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B20">
        <mixed-citation>20. Arcuri EAM. Estudo comparativo da medida indireta da press&#227;o    arterial com manguito de largura correta e com manguito de largura padr&#227;o    (Tese Doutorado) S&#227;o Paulo: Instituto de Ci&#234;ncias Biom&#233;dicas    da Universidade de S&#227;o Paulo, 1985: 175p.</mixed-citation>
        <element-citation publication-type="thesis">
          <source>Estudo comparativo da medida indireta da press&#227;o arterial com manguito de largura correta e com manguito de largura padr&#227;o</source>
          <date>
            <year>1985</year>
          </date>
          <fpage>175</fpage>
          <person-group person-group-type="author">
            <name>
              <surname>Arcuri</surname>
              <given-names>EAM</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B21">
        <mixed-citation>21. Arcuri EAM. Manguito do esfigmoman&#244;metro e diagn&#243;stico    de hipertens&#227;o arterial sist&#234;mica. Arq Bras Cardiol 1989; 52: 181-3.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Manguito do esfigmoman&#244;metro e diagn&#243;stico de hipertens&#227;o arterial sist&#234;mica</article-title>
          <source>Arq Bras Cardiol</source>
          <date>
            <year>1989</year>
          </date>
          <fpage>181</fpage>
          <lpage>3</lpage>
          <volume>52</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Arcuri</surname>
              <given-names>EAM</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B22">
        <mixed-citation>22. Beck FW, Weaver JM, Blozis GG, Unverferth DV. Effect of arm position    and arm support on indirect blood pressure measurements made in a dental chair.    JAMA 1983; 106: 637-45.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Effect of arm position and arm support on indirect blood pressure measurements made in a dental chair</article-title>
          <source>JAMA</source>
          <date>
            <year>1983</year>
          </date>
          <fpage>637</fpage>
          <lpage>45</lpage>
          <volume>106</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Beck</surname>
              <given-names>FW</given-names>
            </name>
            <name>
              <surname>Weaver</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Blozis</surname>
              <given-names>GG</given-names>
            </name>
            <name>
              <surname>Unverferth</surname>
              <given-names>DV</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="TRpt" xml:lang="pt">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigos Originais</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="pt">Avalia&#231;&#227;o de t&#233;cnicas da medida da press&#227;o arterial pelos profissionais de sa&#250;de</article-title>
      </title-group>
      <abstract xml:lang="pt">
        <p>OBJETIVO: Avaliar como a medida da press&#227;o arterial &#233; realizada por profissionais de um hospital p&#250;blico do interior paulista. M&#201;TODOS: Realizaram-se entrevistas semi-estruturadas e observa&#231;&#245;es diretas, por meio de lista de verifica&#231;&#227;o, utilizando-se os crit&#233;rios descritos por Perloff e cols. Participaram 105 profissionais da sa&#250;de. Ap&#243;s a realiza&#231;&#227;o da medida da press&#227;o arterial foi avaliado o n&#237;vel de concord&#226;ncia entre a forma do procedimento realizado e o recomendado. RESULTADOS: Enfermeiros e auxiliares de enfermagem realizaram 40% das etapas dos procedimentos recomendados para uma adequada medida da press&#227;o arterial e nas demais categorias avaliadas, docentes de enfermagem e de medicina, m&#233;dicos, residentes e acad&#234;micos de enfermagem os percentuais ficaram em torno de 70%. CONCLUS&#195;O: H&#225; necessidade de implementar, entre os diferentes profissionais que atuam na &#225;rea da sa&#250;de, atividades de educa&#231;&#227;o permanentemente voltada &#224; padroniza&#231;&#227;o da medida da press&#227;o arterial.</p>
      </abstract>
      <kwd-group xml:lang="pt">
        <kwd>press&#227;o arterial</kwd>
        <kwd>medida da press&#227;o</kwd>
        <kwd>m&#233;todos de medida da press&#227;o</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>ARTIGO ORIGINAL</bold>
      </p>
      <p><undefined id="topo-body2"/>Avalia&#231;&#227;o de t&#233;cnicas da medida da press&#227;o arterial pelos profissionais de sa&#250;de</p>
      <p>
        <bold>Eugenia Velludo Veiga; Maria Suely Nogueira; Evelin Capellari C&#225;rnio; Sueli Marques; Marco Aur&#233;lio S. Lavrador; Suzana Alves de Moraes; Luciana A. C. Souza; Nereida K. C. Lima; Fernando Nobre</bold>
      </p>
      <p>Escola de Enfermagem de Ribeir&#227;o Preto da USP e Hospital das Cl&#237;nicas de Ribeir&#227;o Preto, FMUSP</p>
      <p>Ribeir&#227;o Preto, SP</p>
      <p>Endere&#231;o para correspond&#234;ncia</p>
      <p>
        <bold>RESUMO</bold>
      </p>
      <p><bold>OBJETIVO: </bold>Avaliar como a medida da press&#227;o arterial &#233; realizada por profissionais de um hospital p&#250;blico do interior paulista.</p>
      <p><bold>M&#201;TODOS:</bold> Realizaram-se entrevistas semi-estruturadas e observa&#231;&#245;es diretas, por meio de lista de verifica&#231;&#227;o, utilizando-se os crit&#233;rios descritos por Perloff e cols. Participaram 105 profissionais da sa&#250;de. Ap&#243;s a realiza&#231;&#227;o da medida da press&#227;o arterial foi avaliado o n&#237;vel de concord&#226;ncia entre a forma do procedimento realizado e o recomendado.</p>
      <p><bold>RESULTADOS:</bold> Enfermeiros e auxiliares de enfermagem realizaram 40% das etapas dos procedimentos recomendados para uma adequada medida da press&#227;o arterial e nas demais categorias avaliadas, docentes de enfermagem e de medicina, m&#233;dicos, residentes e acad&#234;micos de enfermagem os percentuais ficaram em torno de 70%.</p>
      <p><bold>CONCLUS&#195;O:</bold> H&#225; necessidade de implementar, entre os diferentes profissionais que atuam na &#225;rea da sa&#250;de, atividades de educa&#231;&#227;o permanentemente voltada &#224; padroniza&#231;&#227;o da medida da press&#227;o arterial.</p>
      <p><bold>Palavras-chave: </bold>press&#227;o arterial, medida da press&#227;o, m&#233;todos de medida da press&#227;o</p>
      <p>A hipertens&#227;o arterial sist&#234;mica &#233; considerada um dos principais fatores de risco para morbidade e mortalidade cardiovasculares, sendo respons&#225;vel por 40% dos casos de aposentadoria precoce e de absente&#237;smo no trabalho <sup>1,2</sup>.</p>
      <p>A medida precisa da press&#227;o arterial &#233; condi&#231;&#227;o essencial para o diagn&#243;stico da hipertens&#227;o, pois a sua eleva&#231;&#227;o &#233;, normalmente, o primeiro sinal da doen&#231;a. Esse &#233; um procedimento simples e f&#225;cil de ser realizado, por&#233;m, se n&#227;o forem atendidos determinados princ&#237;pios para sua realiza&#231;&#227;o estar&#225; sujeito a v&#225;rios fatores de erro com conseq&#252;&#234;ncias pr&#225;ticas de grande vulto <sup>3</sup>. Assim, para a medida precisa da press&#227;o arterial e, consequentemente, o estabelecimento correto do diagn&#243;stico da hipertens&#227;o, &#233; importante determinar crit&#233;rios no desenvolvimento desse procedimento, especialmente relacionados ao ambiente, observador, paciente e equipamento utilizado <sup>4-7</sup>.</p>
      <p>A literatura evidencia a necessidade de padroniza&#231;&#227;o dos crit&#233;rios utilizados na realiza&#231;&#227;o deste procedimento. Al&#233;m disso, a sua execu&#231;&#227;o deve ser feita de forma sistematizada pelos profissionais de sa&#250;de, o que implica na obten&#231;&#227;o de valores reais da press&#227;o arterial, determinando condutas e tratamentos adequados para a doen&#231;a, quando existente <sup>8-12</sup>.</p>
      <p>A partir das avalia&#231;&#245;es cotidianas dos n&#237;veis de press&#227;o arterial em pacientes internados e em atendimentos ambulatoriais, sobretudo observando os profissionais da sa&#250;de executarem este procedimento e, ainda, convivendo com o ensino e a pesquisa deste procedimento ao n&#237;vel de gradua&#231;&#227;o e p&#243;s gradua&#231;&#227;o junto aos alunos de enfermagem e medicina, sentimos necessidade de avali&#225;-lo, &#224; luz dos crit&#233;rios recomendados pela <italic>American Heart Association</italic> em 1993 <sup>6</sup>.</p>
      <p>O presente trabalho tem por objetivo avaliar como a medida da press&#227;o arterial &#233; realizada por profissionais que atuam em um hospital p&#250;blico do interior paulista.</p>
      <p>
        <bold>M&#233;todos</bold>
      </p>
      <p>O projeto foi submetido ao Comit&#234; de &#201;tica em Pesquisa do referido hospital e devidamente aprovado. Posteriormente, solicitou-se aos diretores de uma Escola de Enfermagem e de uma Faculdade de Medicina a lista de docentes que estavam atuando junto &#224;s disciplinas de assist&#234;ncia a indiv&#237;duos nas unidades de interna&#231;&#227;o de: cl&#237;nica m&#233;dica, ginecologia e obstetr&#237;cia, cirurgia, neurologia, ortopedia, otorrinolaringologia e oftalmologia; e dos alunos matriculados no 4&#186; ano do curso de gradua&#231;&#227;o em enfermagem em 1996. &#192; administra&#231;&#227;o do hospital, solicitou-se a lista de m&#233;dicos residentes do 2&#186; ano em atividade, e dos enfermeiros e auxiliares de enfermagem lotados nas especialidades e unidades mencionadas, obtendo-se o total de 662 indiv&#237;duos. Dessa popula&#231;&#227;o, constituiu-se uma amostra aleat&#243;ria de 138 indiv&#237;duos, correspondendo a 20% de cada categoria profissional, sendo que 33 (24%) n&#227;o participaram do estudo por diversos motivos, como: f&#233;rias, folga e licen&#231;a, dentre outros, restando 105 indiv&#237;duos que foram avaliados.</p>
      <p>Para a coleta de dados utilizou-se protocolo onde foram registrados os dados de identifica&#231;&#227;o dos indiv&#237;duos: data da coleta de dados, categoria profissional, idade em anos, sexo, local e ano de conclus&#227;o do curso; procedimento da verifica&#231;&#227;o da press&#227;o arterial, em lista de verifica&#231;&#227;o, contendo os seguintes itens: intera&#231;&#227;o com o examinando, posi&#231;&#227;o do paciente, considerando a posi&#231;&#227;o sentada ou deitada, per&#237;odo de repouso de 3 a 5min antes de verificar a press&#227;o arterial, posi&#231;&#227;o do bra&#231;o do indiv&#237;duo a 45&#176; e ao n&#237;vel do cora&#231;&#227;o, mensura&#231;&#227;o da circunfer&#234;ncia braquial, sele&#231;&#227;o da bolsa infl&#225;vel de borracha, de acordo com a circunfer&#234;ncia braquial, coloca&#231;&#227;o do manguito no bra&#231;o despido, man&#244;metro adequadamente vis&#237;vel, localiza&#231;&#227;o da art&#233;ria braquial, bra&#231;adeira adequadamente envolvida no bra&#231;o, determina&#231;&#227;o pr&#233;via do n&#237;vel de insulfla&#231;&#227;o atrav&#233;s da palpa&#231;&#227;o, desinsulfla&#231;&#227;o do manguito com velocidade de 2 a 3mmHg/s, intervalo de 30s entre duas medidas, posi&#231;&#227;o da camp&#226;nula do estetosc&#243;pio sobre a art&#233;ria braquial; outras informa&#231;&#245;es onde, atrav&#233;s de entrevista semiestruturada e observa&#231;&#227;o direta, eram obtidos os seguintes dados: membro selecionado para verifica&#231;&#227;o da press&#227;o arterial, posi&#231;&#227;o do paciente: sentado, deitado ou de p&#233;; valor press&#227;o arterial em mmHg obtido durante a primeira e a segunda medidas se houvesse; o tipo de esfigmoman&#244;metro utilizado na pr&#225;tica di&#225;ria: aner&#243;ide/coluna de merc&#250;rio; freq&#252;&#234;ncia com que calibra seus equipamentos.</p>
      <p>Os dados foram coletados no per&#237;odo de maio/1996 a dezembro/1997 por cinco pesquisadores previamente treinados quanto &#224; padroniza&#231;&#227;o da medida da press&#227;o arterial e preenchimento do question&#225;rio utilizado.</p>
      <p>Os indiv&#237;duos participantes da pesquisa foram informados quanto aos objetivos do estudo, a raz&#227;o pela qual estavam fazendo parte dele, al&#233;m de solicitada aquiesc&#234;ncia, por escrito, para sua participa&#231;&#227;o.</p>
      <p>A observa&#231;&#227;o e entrevista foram realizadas no local de trabalho de cada indiv&#237;duo observado, elegendo-se previamente um indiv&#237;duo a ser examinado. Pedia-se, ent&#227;o, permiss&#227;o para que sua press&#227;o arterial fosse medida e verificava-se a circunfer&#234;ncia do bra&#231;o desse indiv&#237;duo, sem que o profissional sujeito da pesquisa tomasse conhecimento de tal atitude.</p>
      <p>A medida da press&#227;o arterial era realizada em local apropriado com todos os recursos necess&#225;rios, colocados &#224; disposi&#231;&#227;o dos sujeitos da pesquisa, como: esfigmoman&#244;metros de coluna de merc&#250;rio e aner&#243;ide, manguitos de diferentes larguras, estetosc&#243;pio, fita m&#233;trica e op&#231;&#227;o para local silencioso caso eles quisessem utiliz&#225;-los por considerarem importante para a realiza&#231;&#227;o do procedimento.</p>
      <p>
        <bold>Resultados</bold>
      </p>
      <p>Participaram deste estudo 105 indiv&#237;duos de diferentes categorias profissionais (<xref ref-type="table" rid="tabela1-body2">tab. I</xref>). Em rela&#231;&#227;o ao sexo, 41 (39%) eram homens, enquanto a idade variou entre 20 e 50 (m&#233;dia de 33,6&#177;10,1) anos.</p>
      <table-wrap id="tabela1-body2">
        <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt01-pt.jpg"/></table-wrap>
      <p>Na <xref ref-type="table" rid="t2-body2">tabela II</xref> encontra-se a distribui&#231;&#227;o dos profissionais segundo a categoria e especialidade cl&#237;nica, n&#227;o se incluindo a categoria "aluno de enfermagem" por n&#227;o atuarem em uma unidade de interna&#231;&#227;o espec&#237;fica.</p>
      <p content-type="asset">
        <table-wrap id="t2-body2">
          <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt02-pt.jpg"/></table-wrap>
      </p>
      <p>Dos indiv&#237;duos formados, excluindo-se os estudantes, 47,8% tinham entre 1 e 5 anos de formado (<xref ref-type="table" rid="t3-body2">tab. III</xref>).</p>
      <p content-type="asset">
        <table-wrap id="t3-body2">
          <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt03-pt.jpg"/></table-wrap>
      </p>
      <p>As vari&#225;veis n&#250;mero de mensura&#231;&#245;es realizadas, d&#237;gitos preferenciais, tipo de aparelho utilizado para medida, a calibragem desses instrumentos, dentre outros importantes fatores para a adequada medida da press&#227;o arterial foram tamb&#233;m avaliados na pesquisa, por observa&#231;&#227;o direta e pela entrevista realizada, ap&#243;s a observa&#231;&#227;o da medida da press&#227;o arterial, utilizando-se a lista de verifica&#231;&#227;o.</p>
      <p>Quanto ao n&#250;mero de mensura&#231;&#245;es realizadas, observou-se que a maioria (66,7%) dos indiv&#237;duos identificou valores de press&#227;o arterial por uma &#250;nica medida; 78% dos observados referiram n&#227;o dispor de manguitos adequados para sua pr&#225;tica profissional. Na <xref ref-type="table" rid="tabela4-body2">tabela IV</xref> pode-se identificar a distribui&#231;&#227;o dos d&#237;gitos finais registrados para os valores da press&#227;o arterial sist&#243;lica e da press&#227;o arterial diast&#243;lica e evidenciar a prefer&#234;ncia pelo registro de valores com d&#237;gito zero para a press&#227;o arterial sist&#243;lica em 77,1%, e para press&#227;o arterial diast&#243;lica em 74,3% das medidas. Uma minoria, representada por 17,2% registrou os valores com d&#237;gitos finais para press&#227;o arterial sist&#243;lica e 14,4% para press&#227;o arterial diast&#243;lica entre 2 e 8 enquanto que, 5,7% indicaram d&#237;gitos &#237;mpares (de 1 a 9) para press&#227;o arterial sist&#243;lica e 11,4% o fizeram para a press&#227;o arterial diast&#243;lica.</p>
      <table-wrap id="tabela4-body2">
        <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt04-pt.jpg"/></table-wrap>
      <p>Na <xref ref-type="table" rid="tabela5-body2">tabela V</xref> est&#225; indicada a distribui&#231;&#227;o dos n&#250;meros e percentuais dos tipos de equipamentos referidos como utilizados rotineiramente pelos indiv&#237;duos participantes.</p>
      <table-wrap id="tabela5-body2">
        <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt05-pt.jpg"/></table-wrap>
      <p>Em rela&#231;&#227;o &#224; calibra&#231;&#227;o dos instrumentos de medida, na <xref ref-type="table" rid="tabela6-body2">tabela VI</xref> est&#225; indicada a freq&#252;&#234;ncia referida como realizada pela popula&#231;&#227;o avaliada.</p>
      <table-wrap id="tabela6-body2">
        <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt06-pt.jpg"/></table-wrap>
      <p>A realiza&#231;&#227;o da medida da press&#227;o arterial avaliada neste estudo incluiu 16 etapas descritas de acordo com as recomenda&#231;&#245;es de Perlof e cols. <sup>6</sup>. Na intera&#231;&#227;o com o paciente, isto &#233;, a explica&#231;&#227;o do procedimento ao paciente foi a etapa mais realizada (97,1%), enquanto a sele&#231;&#227;o da largura do manguito adequada foi feita por apenas 6,7% da amostra. Observa-se, ainda, que diversas etapas do procedimento n&#227;o s&#227;o realizadas pelos diferentes profissionais estudados.</p>
      <p>Pode-se observar, ainda, que duas categorias, enfermeiros e auxiliares de enfermagem, realizaram menos de 50% das etapas do procedimento, ao contr&#225;rio das demais por enfermeiros docentes, m&#233;dicos docentes, m&#233;dicos residentes e acad&#234;micos de enfermagem, que realizaram em torno de 70% de todas as etapas.</p>
      <p>A <xref ref-type="table" rid="t7-body2">tabela VII</xref> apresenta os n&#250;meros e percentuais das diferentes categorias profissionais estudadas e as etapas observadas durante o procedimento da medida da press&#227;o arterial, evidenciando que a minoria dos profissionais estudados realizou etapas importantes, como sele&#231;&#227;o do manguito adequado, medida da circunfer&#234;ncia braquial e observ&#226;ncia a intervalos de 30s entre duas medidas.</p>
      <p content-type="asset">
        <table-wrap id="t7-body2">
          <graphic xlink:href="1678-4170-abc-80-01-0089-00008-gt07-pt.jpg"/></table-wrap>
      </p>
      <p>
        <bold>Discuss&#227;o</bold>
      </p>
      <p>Este estudo foi realizado com o objetivo de avaliar a forma como a medida da press&#227;o arterial est&#225; sendo efetuada por diferentes profissionais da &#225;rea da sa&#250;de em atividade em um hospital, levando-se em conta as etapas descritas na literatura e definidas na metodologia deste estudo. V&#225;rios pesquisadores v&#234;m se preocupando em identificar se os profissionais da sa&#250;de t&#234;m realizado este procedimento de modo adequado, uma vez que ele est&#225; diretamente relacionado com a avalia&#231;&#227;o de um par&#226;metro vital <sup>3,13-16</sup>. O que ocorre na pr&#225;tica assistencial entre diferentes profissionais, e em diversos locais, &#233; que a medida da press&#227;o arterial n&#227;o &#233; realizada de forma correta, podendo comprometer os valores obtidos e, conseq&#252;entemente, o diagn&#243;stico, tratamento e controle da hipertens&#227;o. Recentemente, em estudos realizados em S&#227;o Paulo <sup>13,14</sup>, evidenciou-se que o enfermeiro desconhece, em grande parte, o significado da medida da press&#227;o arterial. Outras investiga&#231;&#245;es tamb&#233;m mostram que este procedimento n&#227;o tem sido realizado adequadamente <sup>15,16</sup>.</p>
      <p>&#201; necess&#225;rio chamar a aten&#231;&#227;o para a import&#226;ncia deste procedimento entre profissionais que atuam em diferentes cl&#237;nicas, em pesquisas epidemiol&#243;gicas, em unidades restritas ou em ambulat&#243;rios. Observa-se que tem sido crescente na literatura o n&#250;mero de estudos que envolve erros da medida da press&#227;o arterial atribu&#237;dos aos instrumentos, examinadores e examinados <sup>11</sup>. Al&#233;m da diversidade de profissionais estudados, observa-se que o tempo de formado da maioria foi de 1 a 5 anos. Assim, entende-se que os cursos de gradua&#231;&#227;o podem n&#227;o estar preparando adequadamente os profissionais para esse procedimento espec&#237;fico. A forma&#231;&#227;o do auxiliar de enfermagem destaca pela parte pr&#225;tica e de n&#237;vel fundamental, pois s&#227;o orientados especificamente para a pr&#225;tica hospitalar.</p>
      <p>Neste trabalho analisou-se um conjunto de 16 etapas para a medida da press&#227;o arterial, de acordo com Perloff e cols <sup>6</sup>.</p>
      <p>Das etapas do procedimento da medida indireta da press&#227;o arterial, a menos realizada entre os indiv&#237;duos estudados, foi a sele&#231;&#227;o adequada do manguito apropriado, pois apenas 7% dos indiv&#237;duos preocuparam-se com esse aspecto.</p>
      <p>Ficou evidente que muitas etapas n&#227;o est&#227;o sendo realizadas durante a medida da press&#227;o arterial, fato observado em todas as categorias profissionais. Se considerarmos a import&#226;ncia destas evid&#234;ncias na obten&#231;&#227;o de valores fidedignos da press&#227;o arterial, pode-se depreender a gravidade desses achados, que podem estar comprometendo diretamente os valores obtidos de press&#227;o arterial. Diversos autores v&#234;m afirmando na literatura a import&#226;ncia da cuidadosa medida da press&#227;o arterial, pois os valores obtidos ir&#227;o garantir o estabelecimento correto do diagn&#243;stico da hipertens&#227;o arterial, definir de modo preciso o tratamento e garantir controle e detec&#231;&#227;o precoce da doen&#231;a <sup>3,6,8</sup>.</p>
      <p>Dos indiv&#237;duos avaliados, quando inquiridos, 78% referiram n&#227;o dispor de manguitos de diferentes dimens&#245;es para verifica&#231;&#227;o da press&#227;o arterial. A largura do manguito influi nos valores obtidos de press&#227;o arterial, sendo a press&#227;o subestimada quando utilizados manguitos maiores e superestimada nos casos opostos. Segundo a <italic>American Heart Association</italic> a bolsa de borracha deve ter a largura em torno de 40% da circunfer&#234;ncia do bra&#231;o <sup>17</sup>. Estudos relatam essas diferen&#231;as de hiper e hipoestima&#231;&#227;o em indiv&#237;duos de diferentes faixas et&#225;rias e em gestantes brasileiras <sup>18-21</sup>. As r&#233;guas que permitem corre&#231;&#245;es s&#227;o muito limitadas, pois n&#227;o s&#227;o capazes de corrigir a reatividade vascular, n&#227;o corrigem circunfer&#234;ncias braquiais &lt;20 e &gt;40cm, encontradas com freq&#252;&#234;ncia em obesos e em adultos idosos ou desnutridos. A quest&#227;o dos bra&#231;os finos passa a preocupar ainda mais os pesquisadores por dificultar a identifica&#231;&#227;o precoce dos valores de press&#227;o arterial elevados, podendo comprometer a identifica&#231;&#227;o de altera&#231;&#245;es que n&#227;o influenciar&#227;o no estado de sa&#250;de e na qualidade de vida dos indiv&#237;duos <sup>18-21</sup>. Se os profissionais n&#227;o est&#227;o avaliando a circunfer&#234;ncia braquial, no momento da medida da press&#227;o arterial, est&#227;o impondo erros importantes nos valores que obt&#234;m.</p>
      <p>Em rela&#231;&#227;o ao intervalo entre as mensura&#231;&#245;es, 26,7% aguardaram pelo menos 30s. Realizar a palpa&#231;&#227;o do pulso radial, previamente &#224; insufla&#231;&#227;o do manguito, &#233; de extrema import&#226;ncia, principalmente em idosos, devido &#224; poss&#237;vel calcifica&#231;&#227;o das art&#233;rias e &#224; possibilidade do hiato auscultat&#243;rio. Dos indiv&#237;duos avaliados, somente 53,3% desinsuflaram o manguito com velocidade entre 2-3mmHg/s, como preconizado <sup>8,12</sup>. Desinsulflar o manguito com velocidade r&#225;pida, acima do preconizado, acarreta dificuldade em se estabelecer precisamente os valores press&#243;ricos, tanto sist&#243;licos quanto diast&#243;licos <sup>6,9,14</sup>. Posicionar o membro adequadamente, mantendo o indiv&#237;duo em repouso por um per&#237;odo de 3 a 5min, antes de verificar a press&#227;o arterial, foram etapas que tiveram percentuais de realiza&#231;&#227;o de 64,8% e 66,7% respectivamente, entre os indiv&#237;duos avaliados. O repouso pr&#233;vio, pelo tempo citado, e a manuten&#231;&#227;o do membro superior ao n&#237;vel do cora&#231;&#227;o s&#227;o procedimentos fundamentais, a exemplo de outros, para obten&#231;&#227;o de medidas que expressem a realidade do comportamento tensional <sup>9,10,14,22</sup>.</p>
      <p>Envolver o bra&#231;o com a bra&#231;adeira adequadamente e localizar a art&#233;ria braquial no momento da verifica&#231;&#227;o da press&#227;o arterial foram atos realizados por aproximadamente 70% dos indiv&#237;duos estudados, o que representa um percentual mais aceit&#225;vel e igualmente importante. Posicionar o estetosc&#243;pio, localizar o man&#244;metro para visualizar adequadamente os valores da press&#227;o arterial foram procedimentos realizados por 81% e 82,9% dos indiv&#237;duos, respectivamente, enquanto que a intera&#231;&#227;o com o examinando foi observada em 91,4% da amostra estudada. A verifica&#231;&#227;o da press&#227;o arterial com o bra&#231;o despido foi feita por 97,1% das pessoas. Esse fato pode ter import&#226;ncia, especialmente, se a vestimenta vier a interferir com a espessura do bra&#231;o, falseando a medida.</p>
      <p>Outro fato que influencia na obten&#231;&#227;o de valores corretos da press&#227;o arterial &#233; o n&#250;mero de medidas. Observou-se que 66,7% realizaram uma &#250;nica medida considerando este procedimento como correto.</p>
      <p>Quanto ao registro dos valores de press&#227;o obtidos, 77,1% anotaram zero como d&#237;gito final para press&#227;o arterial sist&#243;lica e 74,3% para a diast&#243;lica. Quando passamos a observar a freq&#252;&#234;ncia das etapas por diferentes profissionais, observa-se que o auxiliar de enfermagem e o enfermeiro s&#227;o os indiv&#237;duos que apresentaram os menores percentuais de realiza&#231;&#227;o das etapas, idealmente propostas para a medida correta da press&#227;o arterial, o que &#233; muito preocupante, tendo em vista que s&#227;o categorias profissionais que atuam, de forma inapropriada, no cotidiano da verifica&#231;&#227;o da press&#227;o arterial sist&#234;mica.</p>
      <p>Concluindo, evidencia-se, em todas as categorias profissionais estudadas, a necessidade de melhor desempenho nas etapas da medida da press&#227;o arterial. Maior aten&#231;&#227;o deve ser dada aos fatores de erro, intimamente ligados &#224; obten&#231;&#227;o dos seus valores, como ambiente, indiv&#237;duo, observador e instrumento. Entende-se que h&#225; necessidade urgente de desenvolver estrat&#233;gias de ensino e aprendizagem para este procedimento, propondo cursos de atualiza&#231;&#227;o, investindo na educa&#231;&#227;o continuada e inserindo conte&#250;dos espec&#237;ficos nos cursos de gradua&#231;&#227;o e p&#243;s-gradua&#231;&#227;o. A multidisciplinaridade que envolve a detec&#231;&#227;o precoce, o tratamento e o controle da hipertens&#227;o arterial, exige do procedimento da medida da press&#227;o arterial uma execu&#231;&#227;o eficaz para obten&#231;&#227;o de dados confi&#225;veis e diagn&#243;sticos precisos.</p>
      <p>
        <bold>Refer&#234;ncias</bold>
      </p>
    </body>
  </sub-article>
</article>
