<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">mXJ6wWv3Z49Zm7whtngJ9ZR</article-id>
      <article-id pub-id-type="other">00007</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X1997000700007</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(97)06900107</article-id>
      <article-id pub-id-type="doi">10.1590/S0066-782X1997000700007</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigos Originais</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Monitoriza&#231;&#227;o ambulatorial da press&#227;o arterial em adolescentes normais</article-title>
        <trans-title-group xml:lang="en">
          <trans-title>Ambulatory blood pressure monitoring in normal adolescents</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Koch</surname>
            <given-names>Vera H.</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Colli</surname>
            <given-names>Anita</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Saito</surname>
            <given-names>Maria Ignez</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Ruffo</surname>
            <given-names>Patricia</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Cardoso</surname>
            <given-names>Rita</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Ignes</surname>
            <given-names>Edna C.</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Okay</surname>
            <given-names>Yassuhiko</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Mion Jr</surname>
            <given-names>D&#233;cio</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date date-type="collection" publication-format="electronic">
        <month>07</month>
        <year>1997</year>
      </pub-date>
      <volume>69</volume>
      <issue>1</issue>
      <fpage>41</fpage>
      <lpage>46</lpage>
      <history>
        <date date-type="received">
          <day>27</day>
          <month>02</month>
          <year>1997</year>
        </date>
        <date date-type="accepted">
          <day>28</day>
          <month>05</month>
          <year>1997</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <abstract>
        <p>OBJETIVO: Avaliar tecnicamente a monitoriza&#231;&#227;o ambulatorial de press&#227;o arterial (MAPA) em adolescentes normais. M&#201;TODOS: Quarenta e cinco adolescentes eutr&#243;ficos, entre 10-18 anos de idade, sendo 27 do sexo feminino. RESULTADOS: Verificaram-se, em m&#233;dia, 90% de medidas bem sucedidas: inc&#244;modo relacionado ao funcionamento do monitor em 30% dos casos; valores m&#233;dios de descenso sist&#243;lico, diast&#243;lico e de diminui&#231;&#227;o de freq&#252;&#234;ncia card&#237;aca, no sono noturno, respectivamente iguais a 13%, 23% e 24%; carga press&#243;rica na vig&#237;lia, no sexo masculino, de 25,4&#177;27,7% e 11,8&#177;14,6% e, no feminino, de 17,5&#177;18,7% e 11,8&#177;11,4% para press&#227;o arterial sist&#243;lica (PAS) e diast&#243;lica (PAD), respectivamente; carga press&#243;rica no sono, no sexo masculino, de 15,4&#177;22,9% e 2,8&#177;4,9% e, no feminino, de 10,5&#177;18,2% e 1,8&#177;2,7% para PAS e PAD; medidas diast&#243;licas mais elevadas nas duas primeiras horas de monitoriza&#231;&#227;o; diferen&#231;as entre sono noturno e vespertino quanto aos par&#226;metros cardiovasculares estudados. CONCLUS&#195;O: A MAPA mostrou-se bem tolerada pela popula&#231;&#227;o adolescente. Os registros obtidos apresentaram-se tecnicamente adequados para an&#225;lise.</p>
      </abstract>
      <trans-abstract xml:lang="en">
        <p>PURPOSE: To evaluate technical aspects of ambulatory blood pressure monitoring (ABPM) in normal adolescents. METHODS: Forty five normal adolescents (27 female), 10-18 years old. RESULTS: ABPM recordings showed a mean of 90% successful readings; 30% of the patients complained of sleep disruption related to the functioning of the ABPM monitor; the mean systolic, diastolic and heart rate fall during sleep was 13%, 23% and 24% respectively; the mean systolic and diastolic blood pressure load, while awake, was in male adolescents 25.4&#177;27.7% and 11.8&#177;14.6%, and in female adolescents, 17.5&#177;18.7% and 11.8&#177;11.4%, respectively; the mean systolic and diastolic blood pressure load, while asleep, was in male adolescents 15.4&#177;22.9% and 2.8&#177;4.9% and, in female adolescents, 10.5&#177;18.2% and 1.8&#177;2.7%, respectively; the mean diastolic values of the first two hours of recording were higher than the ones obtained during the rest of the hours of recording while awake; different mean systolic, diastolic and heart rate values were found during the afternoon and nocturnal sleep periods. CONCLUSION: ABPM was well accepted by the adolescent population, with good technical results.</p>
      </trans-abstract>
      <kwd-group xml:lang="en" kwd-group-type="author-generated">
        <kwd>blood pressure</kwd>
        <kwd>ambulatory blood pressure monitoring</kwd>
        <kwd>adolescent</kwd>
      </kwd-group>
      <kwd-group xml:lang="pt" kwd-group-type="author-generated">
        <kwd>press&#227;o arterial</kwd>
        <kwd>monitoriza&#231;&#227;o ambulatorial de press&#227;o arterial</kwd>
        <kwd>adolescente</kwd>
      </kwd-group>
      <pub-date publication-format="electronic" date-type="pub">
        <day>16</day>
        <month>02</month>
        <year>2001</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>Artigo Original </p>
    <p>
      <bold>Monitoriza&#231;&#227;o Ambulatorial da Press&#227;o Arterial em Adolescentes Normais</bold>
    </p>
    <p>Vera H. Koch, Anita Colli, Maria Ignez Saito, Patricia Ruffo, Rita Cardoso, Edna C. Ignes, Yassuhiko Okay, D&#233;cio Mion Jr </p>
    <p>
      <bold>S&#227;o Paulo, SP </bold>
    </p>
    <p><bold><italic>OBJETIVO: </italic></bold>Avaliar tecnicamente a monitoriza&#231;&#227;o ambulatorial de press&#227;o arterial (MAPA) em adolescentes normais. </p>
    <p><bold><italic>M&#201;TODOS: </italic></bold>Quarenta e cinco adolescentes eutr&#243;ficos, entre 10-18 anos de idade, sendo 27 do sexo feminino. </p>
    <p><bold><italic>RESULTADOS: </italic></bold>Verificaram-se, em m&#233;dia, 90% de medidas bem sucedidas: inc&#244;modo relacionado ao funcionamento do monitor em 30% dos casos; valores m&#233;dios de descenso sist&#243;lico, diast&#243;lico e de diminui&#231;&#227;o de freq&#252;&#234;ncia card&#237;aca, no sono noturno, respectivamente iguais a 13%, 23% e 24%; carga press&#243;rica na vig&#237;lia, no sexo masculino, de 25,4&#177;27,7% e 11,8&#177;14,6% e, no feminino, de 17,5&#177;18,7% e 11,8&#177;11,4% para press&#227;o arterial sist&#243;lica (PAS) e diast&#243;lica (PAD), respectivamente; carga press&#243;rica no sono, no sexo masculino, de 15,4&#177;22,9% e 2,8&#177;4,9% e, no feminino, de 10,5&#177;18,2% e 1,8&#177;2,7% para PAS e PAD; medidas diast&#243;licas mais elevadas nas duas primeiras horas de monitoriza&#231;&#227;o; diferen&#231;as entre sono noturno e vespertino quanto aos par&#226;metros cardiovasculares estudados. </p>
    <p><bold><italic>CONCLUS&#195;O: </italic></bold>A MAPA mostrou-se bem tolerada pela popula&#231;&#227;o adolescente. Os registros obtidos apresentaram-se tecnicamente adequados para an&#225;lise. </p>
    <p><bold>Palavras-chave</bold>: press&#227;o arterial, monitoriza&#231;&#227;o ambulatorial de press&#227;o arterial, adolescente </p>
    <p>
      <bold>Ambulatory Blood Pressure Monitoring in Normal Adolescents </bold>
    </p>
    <p><bold><italic>PURPOSE: </italic></bold>To evaluate technical aspects of ambulatory blood pressure monitoring (ABPM) in normal adolescents. </p>
    <p><bold><italic>METHODS: </italic></bold>Forty five normal adolescents (27 female), 10-18 years old. </p>
    <p><bold><italic>RESULTS: </italic></bold>ABPM recordings showed a mean of 90% successful readings; 30% of the patients complained of sleep disruption related to the functioning of the ABPM monitor; the mean systolic, diastolic and heart rate fall during sleep was 13%, 23% and 24% respectively; the mean systolic and diastolic blood pressure load, while awake, was in male adolescents 25.4&#177;27.7% and 11.8&#177;14.6%, and in female adolescents, 17.5&#177;18.7% and 11.8&#177;11.4%, respectively; the mean systolic and diastolic blood pressure load, while asleep, was in male adolescents 15.4&#177;22.9% and 2.8&#177;4.9% and, in female adolescents, 10.5&#177;18.2% and 1.8&#177;2.7%, respectively; the mean diastolic values of the first two hours of recording were higher than the ones obtained during the rest of the hours of recording while awake; different mean systolic, diastolic and heart rate values were found during the afternoon and nocturnal sleep periods. </p>
    <p><bold><italic>CONCLUSION: </italic></bold>ABPM was well accepted by the adolescent population, with good technical results. </p>
    <p><bold>Key-words</bold>: blood pressure, ambulatory blood pressure monitoring, adolescent </p>
    <p>O emprego da monitoriza&#231;&#227;o ambulatorial de press&#227;o arterial (MAPA) tem se ampliado muito desde a sua introdu&#231;&#227;o. Esta metodologia, apesar de promissora para melhoria do diagn&#243;stico e do seguimento de pacientes hipertensos, ainda est&#225; em fase de normatiza&#231;&#227;o. A pr&#225;tica com a MAPA, na &#225;rea pedi&#225;trica, &#233; ainda incipiente. </p>
    <p>A experi&#234;ncia pedi&#225;trica com a avalia&#231;&#227;o da press&#227;o arterial (PA) pela t&#233;cnica da MAPA, iniciada nos anos 80 ainda &#233; restrita <sup>1-20</sup>. Na crian&#231;a, a MAPA &#233; fact&#237;vel, mostrando dados reprodut&#237;veis, em estudos consecutivos<sup>11</sup>. O desenvolvimento de equipamentos mais leves, do tipo oscilom&#233;trico, favoreceram a utiliza&#231;&#227;o do m&#233;todo em crian&#231;as menores, cujo padr&#227;o intenso de atividade impossibilita registros eficientes, em equipamentos do tipo exclusivamente auscultat&#243;rio. A maioria dos autores tem estudado crian&#231;as maiores de cinco anos de idade. A utiliza&#231;&#227;o do m&#233;todo em neonatos, lactentes e pr&#233;-escolares &#233; ainda muito incipiente e altamente sujeita a insucesso. </p>
    <p>Nosso objetivo foi avaliar, em nosso meio, o grau de aceita&#231;&#227;o desta t&#233;cnica por adolescentes normais urbanos e a qualidade t&#233;cnica do registro obtido, escolhendo para o estudo a faixa et&#225;ria que apresentava as caracter&#237;sticas: alto grau de compreens&#227;o e potencial para avalia&#231;&#227;o cr&#237;tica de procedimentos em geral, capacidade de decis&#227;o quanto &#224; participa&#231;&#227;o volunt&#225;ria em projetos, disposi&#231;&#227;o para elabora&#231;&#227;o de di&#225;rio de atividades realizadas durante a monitoriza&#231;&#227;o. </p>
    <p>M&#233;todos </p>
    <p>Foram avaliados 45 pacientes de 10-18 anos, sendo 27 do sexo feminino e 18 do masculino, em seguimento no Ambulat&#243;rio da Unidade de Adolescentes do Instituto da Crian&#231;a do Hospital das Cl&#237;nicas da FMUSP, que preencheram os seguintes crit&#233;rios de inclus&#227;o: adolescentes com peso e estatura entre os percentis 5 e 95 para idade e sexo <sup>21</sup>; aus&#234;ncia de antecedentes pessoais de doen&#231;a cr&#244;nica; sem uso cr&#244;nico de horm&#244;nios e medica&#231;&#245;es antiinflamat&#243;rias, anticonvulsivantes, anti-histam&#237;nicas, broncodilatadores, digit&#225;licos e hipotensoras; com press&#227;o arterial sist&#243;lica (PAS) e diast&#243;lica (PAD) <underline>&lt;</underline> ao percentil 90 para idade e sexo <sup>22 </sup>; consentimento verbal do adolescente. Os adolescentes selecionados foram submetidos a exame f&#237;sico completo, que compreendeu medidas antropom&#233;tricas (peso, estatura), estadiamento da matura&#231;&#227;o sexual e medida da PA. </p>
    <p>A PA de consult&#243;rio foi medida ao final da consulta m&#233;dica, com esfigmoman&#244;metro de coluna de merc&#250;rio, ap&#243;s repouso de 5min, em posi&#231;&#227;o sentada, no bra&#231;o direito apoiado ao n&#237;vel do cora&#231;&#227;o. Foram utilizados manguitos com largura aproximadamente igual a 75% da dist&#226;ncia entre o cotovelo e o acr&#244;mio e comprimento suficiente para envolver completamente toda a circunfer&#234;ncia do bra&#231;o <sup>23</sup>. Definiu-se como PAS a PA correspondente ao in&#237;cio do 1&#186; ru&#237;do de Korotkoff (K1) e, como PAD, a correspondente &#224; 5&#170; fase de Korotkoff (K5). A PA do paciente em consult&#243;rio foi medida por tr&#234;s vezes sucessivas, com intervalo de aproximadamente 1min entre as medidas, sendo anotada a menor das tr&#234;s. </p>
    <p>A MAPA foi realizada no ambulat&#243;rio da Liga de Hipertens&#227;o do Departamento de Nefrologia do Hospital das Cl&#237;nicas da FMUSP, utilizando-se equipamento SpaceLabs 90207 (metodologia oscilom&#233;trica) e tamanho de manguito semelhante ao empregado para medida auscultat&#243;ria da PA. O m&#233;todo oscilom&#233;trico registra como PAS e PAD valores compar&#225;veis, respectivamente, &#224;s fases K1 e K5. O SpaceLabs 90207 tem valida&#231;&#227;o oficialmente reconhecida pela "<italic>American Association for Advancement of Medical Instrumentation</italic>" <sup>24</sup> e pela "<italic>British Hypertension Society</italic>" <sup>25,26</sup>. Comparado com medidas diretas de PA em pacientes pedi&#225;tricos submetidos a cateteriza&#231;&#227;o card&#237;aca, a diferen&#231;a m&#233;dia entre a medida direta e oscilom&#233;trica de PAS e PAD n&#227;o excedeu a 3,5mmHg <sup>17</sup>. O manguito foi colocado no bra&#231;o n&#227;o dominante do paciente e o monitor preso &#224; sua cintura no lado contralateral aquele ocupado pelo manguito. O aparelho foi ajustado para medidas a cada 10min, durante o dia (6:00-19:00) e 15min, &#224; noite (19:00-6:00), por 24h, com velocidade de defla&#231;&#227;o de 8mmHg/s. </p>
    <p>O monitor foi programado para rejeitar as medidas: freq&#252;&#234;ncia card&#237;aca (FC) &gt;180 e &lt;40bpm; PAS &gt;260 e &lt;70mmHg e PAD &gt;150 e &lt;40mmHg. Medidas consideradas inv&#225;lidas pelo sistema foram repetidas automaticamente, ap&#243;s 3min. O paciente foi orientado a manter o bra&#231;o relaxado durante a infla&#231;&#227;o/defla&#231;&#227;o do aparelho e a retornar ap&#243;s 24h de monitoriza&#231;&#227;o, trazendo um relat&#243;rio com o tipo e a hora das principais atividades realizadas no per&#237;odo. A opini&#227;o do adolescente em rela&#231;&#227;o &#224; interfer&#234;ncia do exame sobre suas atividades quotidianas foi investigada ap&#243;s a retirada do monitor e classificada em: 1) exame sem problemas; 2) interfer&#234;ncia maior durante o dia; 3) interfer&#234;ncia maior durante a noite; 4) inc&#244;modo diurno e noturno. Ap&#243;s a monitoriza&#231;&#227;o de cada paciente, o monitor era conectado a um computador PC compat&#237;vel para gera&#231;&#227;o do relat&#243;rio de PA correspondente. </p>
    <p>Os registros press&#243;ricos obtidos foram estudados com rela&#231;&#227;o aos par&#226;metros: n&#250;mero de horas de monitoriza&#231;&#227;o; n&#250;mero absoluto e percentual de medidas v&#225;lidas; m&#233;dia sist&#243;lica e diast&#243;lica de 24h, de vig&#237;lia e de sono, determinadas com base em informa&#231;&#245;es do di&#225;rio do paciente; queda noturna absoluta e percentual sist&#243;lica e diast&#243;lica; carga press&#243;rica sist&#243;lica e diast&#243;lica de vig&#237;lia para o percentil 95, determinada como n&#250;mero de medidas sist&#243;licas de vig&#237;lia acima da medida de PA correspondente ao percentil 95 da refer&#234;ncia adotada para press&#227;o casual <sup>22</sup>; carga press&#243;rica sist&#243;lica e diast&#243;lica durante o sono: calculada como n&#250;mero de medidas sist&#243;licas registradas durante o sono, superiores a valor 10% abaixo daquele utilizado como limite superior diurno <sup>15</sup>; m&#233;dia de FC de vig&#237;lia e de sono. Foram aceitos para an&#225;lise, registros com pelo menos 70% das medidas v&#225;lidas <sup>12</sup>. </p>
    <p>A an&#225;lise dos di&#225;rios de cada paciente revelou que a rotina de vida dos adolescentes em monitoriza&#231;&#227;o diferiu quanto &#224;s atividades de vig&#237;lia e padr&#245;es de sono, demonstrando que 25 adolescentes, 17 do sexo masculino, n&#227;o exerceram atividades potencialmente geradoras de ansiedade durante a monitoriza&#231;&#227;o (escola, trabalho). Neste grupo, foi poss&#237;vel avaliar os efeitos do per&#237;odo de adapta&#231;&#227;o ao funcionamento do monitor sobre a PAS, PAD e FC de adolescentes normais, atrav&#233;s da compara&#231;&#227;o das m&#233;dias press&#243;ricas e de FC das primeiras 2h de monitoriza&#231;&#227;o em rela&#231;&#227;o ao per&#237;odo restante de vig&#237;lia (vig&#237;lia - 2h). Da mesma forma, nove adolescentes, seis do sexo feminino, apresentaram um per&#237;odo adicional, vespertino, de sono, que pode ser comparado com o sono noturno quanto aos mesmos par&#226;metros. Os dados de PA, FC, descenso press&#243;rico sist&#243;lico e diast&#243;lico no sono e cargas press&#243;ricas s&#227;o apresentados em forma de m&#233;dia e desvio-padr&#227;o . </p>
    <p>A compara&#231;&#227;o da porcentagem m&#233;dia de sucesso na MAPA, entre os sexos masculino e feminino, bem como entre os pacientes que referiram alguma queixa e os que n&#227;o referiram, foi feita atrav&#233;s do teste t-Student <sup>27</sup> para amostras independentes. O coeficiente de correla&#231;&#227;o de Pearson foi calculado entre esta porcentagem e a idade. Em todas as compara&#231;&#245;es realizadas, fixamos o n&#237;vel de 5% para rejei&#231;&#227;o da hip&#243;tese de nulidade. </p>
    <p>A metodologia de an&#225;lise de perfil <sup>28</sup> foi empregada para avaliar o comportamento dos perfis m&#233;dios de PA e FC, nas condi&#231;&#245;es: primeiras duas horas de monitoriza&#231;&#227;o e horas subseq&#252;entes da vig&#237;lia, para o sexo masculino e feminino. </p>
    <p>Resultados </p>
    <p>A proposta de MAPA foi aceita por 70 adolescentes selecionados a partir dos crit&#233;rios de inclus&#227;o adotados neste protocolo. Destes, 46 compareceram ao Ambulat&#243;rio para coloca&#231;&#227;o do monitor de PA na data combinada para o exame. Como um paciente do sexo masculino, de 10,9 anos de idade, desistiu do exame ap&#243;s 30min de monitoriza&#231;&#227;o, foram considerados para an&#225;lise 45 adolescentes normais, o tempo m&#233;dio de seguimento no ambulat&#243;rio de 19,6&#177;18,9 (mediana de 12) meses, com varia&#231;&#227;o de zero a 62 meses. A idade dos pacientes do sexo feminino variou entre 11,1 e 18,0 (m&#233;dia de 15,0&#177;1,9 e mediana de 15) anos, e dos pacientes masculinos, entre 10,6 e 17,8 (m&#233;dia de 14,3&#177;2,0 e mediana de 14) anos. A an&#225;lise da casu&#237;stica quanto &#224; cor revelou 32 (71%) brancos, 13 do sexo masculino e 19 do feminino, e 13 (29%) mulatos e negros, 5 do sexo masculino e 8 do feminino. A <xref ref-type="table" rid="tabelai">tabela I</xref> resume as caracter&#237;sticas da casu&#237;stica quanto &#224; idade, peso, altura e &#237;ndice de massa corp&#243;rea, em ambos os sexos. </p>
    <table-wrap id="tabelai">
      <graphic xlink:href="1678-4170-abc-69-01-0041-00007-gt01.jpg"/></table-wrap>
    <p>A MAPA transcorreu, sem intercorr&#234;ncias, em 43 pacientes. Um paciente do sexo masculino retornou ao ambulat&#243;rio, ap&#243;s 21h de exame, solicitando a retirada do monitor antes do tempo previsto, devido a fadiga, e um outro, do sexo masculino, assustou-se na 1&#170; hora de exame, com as infla&#231;&#245;es e defla&#231;&#245;es sucessivas do equipamento, mas, ap&#243;s nova explica&#231;&#227;o sobre o seu funcionamento, permaneceu em uso do mesmo pelo per&#237;odo previsto. Os dados referentes a tempo de monitoriza&#231;&#227;o, n&#250;mero de medidas realizadas e porcentagem de medidas bem sucedidas, encontram-se na <xref ref-type="table" rid="tabelaii">tabela II</xref>. Uma paciente do sexo feminino diferenciou-se do restante da casu&#237;stica pois, por falha na programa&#231;&#227;o, foram registradas medidas a cada 20min durante o dia e a cada 60min entre 23:00 e 8:00h, perfazendo um total de 53 medidas, 96% das quais bem sucedidas, em 25h de monitoriza&#231;&#227;o. N&#227;o houve diferen&#231;a estatisticamente significativa entre as m&#233;dias das porcentagens de medidas bem sucedidas no sexo masculino e feminino (p=0,3885). A idade do paciente n&#227;o afetou a efici&#234;ncia da monitoriza&#231;&#227;o (r=0,16; p=0,3020). </p>
    <table-wrap id="tabelaii">
      <graphic xlink:href="1678-4170-abc-69-01-0041-00007-gt02.jpg"/></table-wrap>
    <p>A <xref ref-type="table" rid="tabelaiii">tabela III</xref> apresenta a distribui&#231;&#227;o dos pacientes quanto &#224;s opini&#245;es emitidas sobre a interfer&#234;ncia da monitoriza&#231;&#227;o no seu cotidiano e sua rela&#231;&#227;o com a m&#233;dia de sucesso obtida no exame. A an&#225;lise estat&#237;stica realizada, dividindo-se a casu&#237;stica em pacientes "com" e "sem" problemas durante a monitoriza&#231;&#227;o, demonstrou porcentagem de sucesso significantemente maior no grupo de adolescentes que se sentiu incomodado pelo exame (p=0,0139). </p>
    <table-wrap id="tabelaiii">
      <graphic xlink:href="1678-4170-abc-69-01-0041-00007-gt03.jpg"/></table-wrap>
    <p>Os dados obtidos de PAS, durante a monitoriza&#231;&#227;o, foram: m&#233;dia de 24h (111,1&#177;5,6 no feminino e 115,0&#177;9,7 no masculino); m&#233;dia nas horas de vig&#237;lia (116,4&#177;6,3 no feminino e 120,5&#177;10,3 no masculino); m&#233;dia nas horas de sono noturno (101,1&#177;6,3 no feminino e 104,6&#177;8,9 no masculino) e de PAD, respectivamente, 24h 67,5&#177;4,1 no feminino e 67,4&#177;6,2 no masculino; vig&#237;lia 73,4&#177;4,6 no feminino e 74,0&#177;6,7 no masculino; sono noturno 56,7&#177;5,0 no feminino e 57,1&#177;5,5 no masculino. A m&#233;dia nas horas de vig&#237;lia foi significativamente maior do que a m&#233;dia nas horas de sono noturno, para ambos os sexos (p=0,0001). </p>
    <p>Os dados de FC, durante a monitoriza&#231;&#227;o foram: m&#233;dia de 24h 85,1&#177;7,8 no feminino e 78,9&#177;7,9 no masculino; m&#233;dia nas horas de vig&#237;lia 92,7&#177;9,2 no feminino e 86,1&#177;7,7 no masculino e m&#233;dia nas horas de sono noturno 70,9&#177;7,8 no feminino e 65,8&#177;8,6 no masculino. A m&#233;dia nas horas de vig&#237;lia foi, significativamente maior do que a m&#233;dia nas horas de sono noturno, em ambos os sexos (p=0,0001). As m&#233;dias de FC, nas duas situa&#231;&#245;es, foram maiores no sexo feminino em rela&#231;&#227;o ao masculino (p=0,0139). </p>
    <p>A PAS m&#233;dia, nas duas primeiras horas de monitoriza&#231;&#227;o, foi de 118,7&#177;7,2mmHg, no sexo feminino e de 124,1&#177;10,6mmHg, no masculino e a PAD m&#233;dia de 75,8&#177;5,5mmHg, no sexo feminino e de 77,6&#177;5,7mmHg, no masculino. As m&#233;dias press&#243;ricas sist&#243;licas e diast&#243;licas nas horas subseq&#252;entes de vig&#237;lia foram, respectivamente, para o sexo feminino e masculino iguais a 116,6&#177;6,5 e 123,2&#177;10,7mmHg e de 71,5&#177;4,6mmHg e 74,4&#177;7,7mmHg. N&#227;o houve diferen&#231;as significativas entre os dois per&#237;odos, tanto para o sexo masculino quanto para o feminino (p=0,2639) com rela&#231;&#227;o &#224; PAS, mas houve diferen&#231;a significativa entre os dois per&#237;odos (p=0,0001), conjuntamente para o sexo masculino e feminino com refer&#234;ncia &#224; PAD. </p>
    <p>A FC m&#233;dia, nas primeiras duas horas de monitoriza&#231;&#227;o, foi de 93,7&#177;13,6bpm, no sexo feminino e de 85,9&#177;9,1 no masculino. A FC, em bpm, nas horas subseq&#252;entes de vig&#237;lia foi respectivamente, para o sexo feminino e masculino, igual a 92,3&#177;9,0 e 87,3&#177;9,2mmHg. N&#227;o houve diferen&#231;a significativa entre os perfis m&#233;dios dos dois per&#237;odos, para o sexo masculino e feminino (p=1,000). </p>
    <p>A <xref ref-type="table" rid="tabelaiv">tabela IV</xref> apresenta os dados relativos ao descenso press&#243;rico sist&#243;lico e diast&#243;lico observado no sono noturno, no grupo estudado, a <xref ref-type="table" rid="tabelav">tabela V</xref> os dados relacionados &#224; carga press&#243;rica m&#233;dia sist&#243;lica e diast&#243;lica observados na vig&#237;lia e no sono noturno, em rela&#231;&#227;o ao percentil 95 da normatiza&#231;&#227;o adotada <sup>22</sup> e a <xref ref-type="table" rid="tabelavi">tabela VI</xref> as m&#233;dias de press&#227;o sist&#243;lica, diast&#243;lica e de FC, nos dois sonos. </p>
    <table-wrap id="tabelaiv">
      <graphic xlink:href="1678-4170-abc-69-01-0041-00007-gt04.jpg"/></table-wrap>
    <table-wrap id="tabelav">
      <graphic xlink:href="1678-4170-abc-69-01-0041-00007-gt05.jpg"/></table-wrap>
    <table-wrap id="tabelavi">
      <graphic xlink:href="1678-4170-abc-69-01-0041-00007-gt06.jpg"/></table-wrap>
    <p>Discuss&#227;o </p>
    <p>A MAPA foi bem tolerada no grupo estudado. Houve apenas uma desist&#234;ncia antes do t&#233;rmino da investiga&#231;&#227;o (2%), valor este inferior ao encontrado por Egger e col <sup>3</sup> e Reichert e col <sup>17</sup>, em adolescentes volunt&#225;rios normais, e por Nishibata e col <sup>18</sup>, em adolescentes hipertensos, de 9,3%, 5% e 16%, respectivamente. A porcentagem de medidas bem sucedidas em nossa casu&#237;stica, em m&#233;dia de 90%, foi compar&#225;vel &#224; de Lurbe e col <sup>12</sup> , superior &#224; de Reichert e col <sup>17</sup> de 66% e inferior &#224; de Reusz e col <sup>13</sup> de 97,5%, estudos que utilizaram metodologia oscilom&#233;trica para medida de PA. A disparidade dos dados em rela&#231;&#227;o ao sucesso da monitoriza&#231;&#227;o se deve, em parte, &#224; pr&#225;tica de esportes durante o procedimento, liberada em nosso estudo e no de Reichert e col <sup>17</sup>, aceita com modera&#231;&#227;o por Lurbe e col <sup>12</sup> e contra-indicada por Reusz e col <sup>13</sup>. O inc&#244;modo relacionado ao funcionamento do monitor, durante o per&#237;odo de sono, ocorreu isoladamente em 24% dos pacientes e, em associa&#231;&#227;o a interfer&#234;ncia com atividades diurnas, em 6% dos casos. Valores esperados e confirmados por dados de Portman e col <sup>7</sup> em dist&#250;rbios de sono na vig&#234;ncia de monitoriza&#231;&#227;o em 27% dos pacientes pedi&#225;tricos normais. </p>
    <p>No presente trabalho, utilizamos a hora real de sono e vig&#237;lia obtidas a partir das informa&#231;&#245;es contidas nos di&#225;rios preenchidos pelos adolescentes, para o c&#225;lculo dos par&#226;metros de sono e vig&#237;lia. Esta conduta &#233;, atualmente, considerada mais correta do que aquela que atribui hor&#225;rios padronizados para an&#225;lise dos registros de 24h, baseados nos h&#225;bitos da maioria da popula&#231;&#227;o e n&#227;o nas informa&#231;&#245;es pessoais de cada paciente, pois confere precis&#227;o ao c&#225;lculo da queda sist&#243;lica e diast&#243;lica e da carga press&#243;rica sist&#243;lica e diast&#243;lica no sono <sup>29-31</sup>. Esta pr&#225;tica &#233;, no entanto, de dif&#237;cil aplicabilidade em casu&#237;sticas maiores, em cuja an&#225;lise, freq&#252;entemente, s&#227;o adotados hor&#225;rios pr&#233;-determinados para vig&#237;lia e para o sono. Dentre os estudos pedi&#225;tricos, Nishibata e col <sup>18</sup> chamaram de vig&#237;lia ao per&#237;odo entre 10:00 e 22:00h e o de sono, entre 1:00 e 6:00h da manh&#227;. Lurbe e col <sup>12,19 </sup>definiram vig&#237;lia como o per&#237;odo entre 8:00 e 22:00h e o de sono, entre 24:00 e 6:00h da manh&#227;. Outros autores <sup>7,14</sup> conseguiram analisar grandes grupos de pacientes utilizando o hor&#225;rio real de atividades contido em seus di&#225;rios. </p>
    <p>Os dados comparativos de vig&#237;lia e sono, documentados neste estudo, somam-se &#224;queles j&#225; publicados para adultos e crian&#231;as, quanto &#224; presen&#231;a de um padr&#227;o vig&#237;lia - sono de PA e FC, com valores durante a vig&#237;lia superiores &#224;queles obtidos durante o sono. Observamos, em nossa casu&#237;stica, em m&#233;dia, para ambos os sexos, no sono principal, queda sist&#243;lica de 13%, queda diast&#243;lica de 23% e diminui&#231;&#227;o da FC em 24%, com dados semelhantes apresentados em outros estudos pedi&#225;tricos <sup>9,12</sup>. </p>
    <p>A an&#225;lise da carga press&#243;rica, em rela&#231;&#227;o ao percentil 95 da normatiza&#231;&#227;o adotada <sup>22 </sup>demonstrou valores na vig&#237;lia no sexo masculino de 25,4&#177;27,7% e 11,8&#177;14,6% e no sexo feminino, de 17,5&#177;18,7 % e 11,8&#177;11,4% para PAS e PAD, respectivamente. Os valores de carga press&#243;rica no sono foram, no sexo masculino, de 15,2&#177;22,9% e 2,8&#177;4,9% e no sexo feminino, de 10,5&#177;18,2% e 1,8&#177;2,7%, para PAS e PAD. Estes valores diferem dos de Portman e col <sup>7</sup> para ambos os sexos, de 15,3&#177;14,9% e 9,9&#177;9,8%, 10,1&#177;11,7% e 7,1&#177;11,8%, respectivamente para PAS e PAD, na vig&#237;lia e no sono pois, para an&#225;lise espec&#237;fica os autores padronizaram como vig&#237;lia, o per&#237;odo entre 6:00 e 18:00h e como sono, as 12h restantes do dia. No adulto, valores de carga press&#243;rica sist&#243;lica e diast&#243;lica superiores, respectivamente, a 50% e 40%, est&#227;o relacionados, em hipertensos, a maior preval&#234;ncia de altera&#231;&#245;es card&#237;acas secund&#225;rias &#224; hipertens&#227;o arterial <sup>32</sup>. A carga press&#243;rica &#233; um par&#226;metro para o qual n&#227;o h&#225; defini&#231;&#227;o de normalidade na crian&#231;a, n&#227;o sendo conhecida a sua morbidade. </p>
    <p>O estudo em separado das duas primeiras horas de monitoriza&#231;&#227;o foi poss&#237;vel nos adolescentes que n&#227;o foram &#224; escola ou ao trabalho no dia da monitoriza&#231;&#227;o. As medidas da PAD mostraram-se significativamente mais elevadas nas primeiras horas do procedimento, em ambos os sexos, provavelmente associadas &#224; adapta&#231;&#227;o ao funcionamento intermitente do equipamento. O efeito das duas primeiras horas de monitoriza&#231;&#227;o foi avaliado em 50 adultos hipertensos, por Prasad e col <sup>33</sup>, atrav&#233;s da an&#225;lise de registros de 48h consecutivas. A compara&#231;&#227;o das primeiras 2h de exame com o mesmo per&#237;odo do 2&#186; dia de exame revelou n&#237;veis press&#243;ricos mais elevados no 1&#186; per&#237;odo, gerando a proposi&#231;&#227;o de que registros de MAPA sejam realizados por 26h consecutivas, desprezando-se as duas primeiras horas no c&#225;lculo global dos par&#226;metros estudados. </p>
    <p>O cuidado dos adolescentes na elabora&#231;&#227;o dos di&#225;rios de atividades, possibilitou-nos a constata&#231;&#227;o de um sono vespertino em nove registros. No entanto, o n&#250;mero pequeno de registros em que esse comportamento ocorreu n&#227;o nos permitiu conclus&#245;es comparativas definitivas sobre o sono vespertino e o sono noturno. Pode-se apreender que apesar das m&#233;dias de PAS, PAD e de FC no sono noturno e vespertino serem consistentemente mais baixas do que os respectivos valores na vig&#237;lia, estes valores s&#227;o diferentes entre si, o que se reflete por dados diferentes de descenso press&#243;rico e carga press&#243;rica. Burztyn e col <sup>34</sup> compararam o sono da tarde com o sono noturno em 16 pacientes normotensos e 24 hipertensos adultos demonstrando par&#226;metros press&#243;ricos semelhantes e enfatizaram que o descenso press&#243;rico e de FC observados no sono vespertino poderiam constituir fator potencial de falsa diminui&#231;&#227;o dos valores m&#233;dios destas vari&#225;veis, se este per&#237;odo n&#227;o fosse exclu&#237;do da an&#225;lise do per&#237;odo de vig&#237;lia, fato corriqueiro quando s&#227;o adotados hor&#225;rios fixos de sono e vig&#237;lia, para estudo dos dados de monitoriza&#231;&#227;o, em vez daqueles estabelecidos pelo di&#225;rio dos pacientes. Nosso estudo e o de Burztyn e col <sup>34</sup> refor&#231;am a necessidade de valoriza&#231;&#227;o do preenchimento, pelos pacientes em monitoriza&#231;&#227;o, de di&#225;rios minuciosos de atividade, para que sua an&#225;lise possa gerar dados mais fidedignos. </p>
    <p>Concluindo, a utiliza&#231;&#227;o da MAPA &#233; uma medida aceit&#225;vel em nosso meio, sendo bem tolerada pela popula&#231;&#227;o adolescente e sem dificuldades t&#233;cnicas. Os registros obtidos apresentaram qualidade t&#233;cnica compar&#225;vel &#224; descrita pela escassa literatura pertinente. No entanto, a falta de normatiza&#231;&#227;o dos dados obtidos, o desconhecimento dos par&#226;metros de normalidade para o m&#233;todo, constituem, atualmente, dificuldades log&#237;sticas s&#233;rias para a sua utiliza&#231;&#227;o rotineira. Estudos pedi&#225;tricos t&#234;m demonstrado <sup>12,14,20 </sup>que os valores das press&#245;es medidas durante a monitoriza&#231;&#227;o na crian&#231;a e no adolescente, apesar de altamente correlacionados com aqueles de press&#227;o casual obtidos em consult&#243;rio, s&#227;o normalmente superiores aos mesmos. Esta aparente incongru&#234;ncia explica-se pois, a medida casual e a MAPA, apesar de estarem aferindo a mesma vari&#225;vel, o fazem em condi&#231;&#245;es t&#233;cnicas e ambientais diversas, incompat&#237;veis e n&#227;o intercambi&#225;veis. Os valores dos par&#226;metros de normalidade para press&#227;o casual n&#227;o devem, portanto, ser aplicados &#224; MAPA. A utiliza&#231;&#227;o da MAPA deve ser precedida da constru&#231;&#227;o de sua normatiza&#231;&#227;o, baseada em estudos populacionais, para estabelecimento de valores espec&#237;ficos por idade, sexo e altura. </p>
    <p>Instituto da Crian&#231;a e Liga de Hipertens&#227;o do Hospital das Cl&#237;nicas da FMUSP </p>
    <p> Correspond&#234;ncia: Vera H. Koch - Instituto da Crian&#231;a - HCFMUSP - Av. Dr. En&#233;as C. Aguiar, 647 - 05403-000 - S&#227;o Paulo, SP </p>
    <p> Recebido para publica&#231;&#227;o em 27/2/97 </p>
    <p> Aceito em 28/5/97 </p>
  </body>
  <back>
    <ref-list>
      <ref id="B1">
        <mixed-citation>1. Langewitz W, Von Eiff AW, Gogolin E, Neus H, R&#252;ddel H, Schmieder R - Reliability and validity of ambulatory blood pressure recording in children.<bold> </bold>Clin Exp Theory and Practice 1985; A7: 217-25. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Reliability and validity of ambulatory blood pressure recording in children</article-title>
          <source>Clin Exp Theory and Practice</source>
          <date>
            <year>1985</year>
          </date>
          <fpage>217</fpage>
          <lpage>25</lpage>
          <volume>A7</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Langewitz</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Von Eiff</surname>
              <given-names>AW</given-names>
            </name>
            <name>
              <surname>Gogolin</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Neus</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>R&#252;ddel</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Schmieder</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Daniels RS, Loggie JMH, Burton T, Kaplan S - Difficulties in ambulatory blood pressure monitoring in children.<bold> </bold>J. Pediatr 1987; 111:397-400. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Difficulties in ambulatory blood pressure monitoring in children</article-title>
          <source>J. Pediatr</source>
          <date>
            <year>1987</year>
          </date>
          <fpage>397</fpage>
          <lpage>400</lpage>
          <volume>111</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Daniels</surname>
              <given-names>RS</given-names>
            </name>
            <name>
              <surname>Loggie</surname>
              <given-names>JMH</given-names>
            </name>
            <name>
              <surname>Burton</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Kaplan</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. Egger M, Bianchetti MG, Gnadinger M, Kobelt R, Oetliker O - Twenty-four hour intermittent, ambulatory blood pressure monitoring. Arch Dis Child 1987; 62: 1130-5. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Twenty-four hour intermittent, ambulatory blood pressure monitoring</article-title>
          <source>Arch Dis Child</source>
          <date>
            <year>1987</year>
          </date>
          <fpage>1130</fpage>
          <lpage>5</lpage>
          <volume>62</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Egger</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Bianchetti</surname>
              <given-names>MG</given-names>
            </name>
            <name>
              <surname>Gnadinger</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Kobelt</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Oetliker</surname>
              <given-names>O</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Wilson PD, Ferencz C, Dischinger PC, Brenner JI, Zeger SL - Twenty-four-hour ambulatory blood pressure in normotensive adolescent children of hypertensive and normotensive parents. Am J Epidemiol 1988; 127: 946-54. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Twenty-four-hour ambulatory blood pressure in normotensive adolescent children of hypertensive and normotensive parents</article-title>
          <source>Am J Epidemiol</source>
          <date>
            <year>1988</year>
          </date>
          <fpage>946</fpage>
          <lpage>54</lpage>
          <volume>127</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Wilson</surname>
              <given-names>PD</given-names>
            </name>
            <name>
              <surname>Ferencz</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Dischinger</surname>
              <given-names>PC</given-names>
            </name>
            <name>
              <surname>Brenner</surname>
              <given-names>JI</given-names>
            </name>
            <name>
              <surname>Zeger</surname>
              <given-names>SL</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. Cugini P, Girelli I, Latini M et al - Chronobiology of blood pressure in childhood. Chronobiologia 1988<bold>;</bold> 15: 291-8. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Chronobiology of blood pressure in childhood</article-title>
          <source>Chronobiologia</source>
          <date>
            <year>1988</year>
          </date>
          <fpage>291</fpage>
          <lpage>8</lpage>
          <volume>15</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Cugini</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Girelli</surname>
              <given-names>I</given-names>
            </name>
            <name>
              <surname>Latini</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B6">
        <mixed-citation>6. Fixler DE, Wallace JM, Thornton WE, Dimmitt P - Ambulatory blood pressure monitoring in hypertensive adolescents. Am J Hypertens 1990; 3: 288-92. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Ambulatory blood pressure monitoring in hypertensive adolescents</article-title>
          <source>Am J Hypertens</source>
          <date>
            <year>1990</year>
          </date>
          <fpage>288</fpage>
          <lpage>92</lpage>
          <volume>3</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Fixler</surname>
              <given-names>DE</given-names>
            </name>
            <name>
              <surname>Wallace</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Thornton</surname>
              <given-names>WE</given-names>
            </name>
            <name>
              <surname>Dimmitt</surname>
              <given-names>P</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B7">
        <mixed-citation>7. Portman RJ, Yetman RJ, West S - Efficacy of 24-hour blood pressure monitoring in children. J Pediatr<bold> </bold>1991; 118: 842-9. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Efficacy of 24-hour blood pressure monitoring in children</article-title>
          <source>J Pediatr</source>
          <date>
            <year>1991</year>
          </date>
          <fpage>842</fpage>
          <lpage>9</lpage>
          <volume>118</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Portman</surname>
              <given-names>RJ</given-names>
            </name>
            <name>
              <surname>Yetman</surname>
              <given-names>RJ</given-names>
            </name>
            <name>
              <surname>West</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B8">
        <mixed-citation>8. Bald M, Kubel S, Rascher W - 24-Hour blood pressure measurement in normal children and adolescents.<bold> </bold>Z Cardiol 1992; 81(suppl 2): 1-4. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>24-Hour blood pressure measurement in normal children and adolescents</article-title>
          <source>Z Cardiol</source>
          <date>
            <year>1992</year>
          </date>
          <fpage>1</fpage>
          <lpage>4</lpage>
          <volume>81</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Bald</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Kubel</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Rascher</surname>
              <given-names>W</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B9">
        <mixed-citation>9. Krull F, Buck T, Offner G, Brodehl J - Twenty-four hour blood pressure monitoring in healthy children. Eur J Pediatr<bold> </bold>1993;<bold> </bold>152: 555-8. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Twenty-four hour blood pressure monitoring in healthy children</article-title>
          <source>Eur J Pediatr</source>
          <date>
            <year>1993</year>
          </date>
          <fpage>555</fpage>
          <lpage>8</lpage>
          <volume>152</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Krull</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Buck</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Offner</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Brodehl</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B10">
        <mixed-citation>10. Nicholson WR, Matthews JNS, O'Sullivan JJ, Wren C - Ambulatory blood pressure monitoring. Arch Dis Child 1993; 69:681-4. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Ambulatory blood pressure monitoring</article-title>
          <source>Arch Dis Child</source>
          <date>
            <year>1993</year>
          </date>
          <fpage>681</fpage>
          <lpage>4</lpage>
          <volume>69</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Nicholson</surname>
              <given-names>WR</given-names>
            </name>
            <name>
              <surname>Matthews</surname>
              <given-names>JNS</given-names>
            </name>
            <name>
              <surname>O'Sullivan</surname>
              <given-names>JJ</given-names>
            </name>
            <name>
              <surname>Wren</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B11">
        <mixed-citation>11. Lurbe E, Aguilar F, Gomez A, Tacons J, Alvarez V, Redon J - Reproducibility of ambulatory blood pressure monitoring in children.<bold> </bold>J Hypertens 1993; 11(suppl 5): S288- S9. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Reproducibility of ambulatory blood pressure monitoring in children</article-title>
          <source>J Hypertens</source>
          <date>
            <year>1993</year>
          </date>
          <fpage>S288</fpage>
          <lpage> S9</lpage>
          <volume>11</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Lurbe</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Aguilar</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Gomez</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Tacons</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Alvarez</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Redon</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B12">
        <mixed-citation>12. Lurbe E, Redon J, Liao Y, Tacons J, Cooper RS, Alvarez V - Ambulatory blood pressure monitoring in normotensive children. J Hypertens 1994; 12: 1417-23 </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Ambulatory blood pressure monitoring in normotensive children</article-title>
          <source>J Hypertens</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>1417</fpage>
          <lpage>23</lpage>
          <volume>12</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Lurbe</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Redon</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Liao</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Tacons</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Cooper</surname>
              <given-names>RS</given-names>
            </name>
            <name>
              <surname>Alvarez</surname>
              <given-names>V</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B13">
        <mixed-citation>13. Reusz GS, Hobor M, Tulassey T, Sallay P, Miltenyi M - 24-Hour blood pressure monitoring in healthy and hypertensive children.<bold> </bold>Arch Dis Child<bold> </bold>1994;<bold> </bold>70: 90-4. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>24-Hour blood pressure monitoring in healthy and hypertensive children</article-title>
          <source>Arch Dis Child</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>90</fpage>
          <lpage>4</lpage>
          <volume>70</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Reusz</surname>
              <given-names>GS</given-names>
            </name>
            <name>
              <surname>Hobor</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Tulassey</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Sallay</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Miltenyi</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B14">
        <mixed-citation>14. Harshfield GA, Alpert S, Pulliam DA, Somes GW, Wilson DK - Ambulatory blood pressure recordings in children and adolescents. Pediatrics<bold> </bold>1994; 94: 180-4. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Ambulatory blood pressure recordings in children and adolescents</article-title>
          <source>Pediatrics</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>180</fpage>
          <lpage>4</lpage>
          <volume>94</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Harshfield</surname>
              <given-names>GA</given-names>
            </name>
            <name>
              <surname>Alpert</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Pulliam</surname>
              <given-names>DA</given-names>
            </name>
            <name>
              <surname>Somes</surname>
              <given-names>GW</given-names>
            </name>
            <name>
              <surname>Wilson</surname>
              <given-names>DK</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B15">
        <mixed-citation>15. Portman RJ, Yetman RJ - Clinical uses of ambulatory blood pressure monitoring. Pediatr Nephrol 1994;<bold> </bold>8: 367-76. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Clinical uses of ambulatory blood pressure monitoring</article-title>
          <source>Pediatr Nephrol</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>367</fpage>
          <lpage>76</lpage>
          <volume>8</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Portman</surname>
              <given-names>RJ</given-names>
            </name>
            <name>
              <surname>Yetman</surname>
              <given-names>RJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B16">
        <mixed-citation>16. Yetman RJ, West MS, Portman RJ - Chronobiologic evaluation of blood pressure in school children<bold>. </bold>Chronobiol Int 1994; 11: 132-40. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Chronobiologic evaluation of blood pressure in school children</article-title>
          <source>Chronobiol Int</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>132</fpage>
          <lpage>40</lpage>
          <volume>11</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Yetman</surname>
              <given-names>RJ</given-names>
            </name>
            <name>
              <surname>West</surname>
              <given-names>MS</given-names>
            </name>
            <name>
              <surname>Portman</surname>
              <given-names>RJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B17">
        <mixed-citation>17. Reichert H, Lindinger A, Frey O et al - Ambulatory blood pressure monitoring in healthy children. Pediatr Nephrol<bold> </bold>1995;<bold> </bold>9: 282-6. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Ambulatory blood pressure monitoring in healthy children</article-title>
          <source>Pediatr Nephrol</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>282</fpage>
          <lpage>6</lpage>
          <volume>9</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Reichert</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Lindinger</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Frey</surname>
              <given-names>O</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B18">
        <mixed-citation>18. Nishibata K, Nagashima M, Tsuji A et al - Comparison of casual blood pressure and twenty-four-hour ambulatory blood pressure in high school students. J Pediatr 1995; 157: 34-9. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Comparison of casual blood pressure and twenty-four-hour ambulatory blood pressure in high school students</article-title>
          <source>J Pediatr</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>34</fpage>
          <lpage>9</lpage>
          <volume>157</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Nishibata</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Nagashima</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Tsuji</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B19">
        <mixed-citation>19. Lurbe E, Thijs L, Redon J, Alvarez V, Tacons J, Staessen J - Diurnal blood pressure curve in children and adolescents. J Hypertens 1996; 14: 41-6. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Diurnal blood pressure curve in children and adolescents</article-title>
          <source>J Hypertens</source>
          <date>
            <year>1996</year>
          </date>
          <fpage>41</fpage>
          <lpage>6</lpage>
          <volume>14</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Lurbe</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Thijs</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Redon</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Alvarez</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Tacons</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Staessen</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B20">
        <mixed-citation>20. Koch VH - Press&#259;o arterial casual e monitoriza&#231;&#259;o ambulatorial de press&#259;o arterial em adolescentes normais (Tese Doutorado). S&#259;o Paulo: Faculdade de Medicina-USP, 1996, 116p. </mixed-citation>
        <element-citation publication-type="thesis">
          <source>Press&#227;o arterial casual e monitoriza&#231;&#227;o ambulatorial de press&#227;o arterial em adolescentes normais</source>
          <date>
            <year>1996</year>
          </date>
          <fpage>116</fpage>
          <person-group person-group-type="author">
            <name>
              <surname>Koch</surname>
              <given-names>VH</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B21">
        <mixed-citation>21. Hamill PVV, Drizd TA, Johnson CL, Reed RB, Roche AF, Moore WM - Physical growth: National Center for Health Statistics percentiles. Am J Clin Nutr 1979; 32: 607-29. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Physical growth: National Center for Health Statistics percentiles</article-title>
          <source>Am J Clin Nutr</source>
          <date>
            <year>1979</year>
          </date>
          <fpage>607</fpage>
          <lpage>29</lpage>
          <volume>32</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Hamill</surname>
              <given-names>PVV</given-names>
            </name>
            <name>
              <surname>Drizd</surname>
              <given-names>TA</given-names>
            </name>
            <name>
              <surname>Johnson</surname>
              <given-names>CL</given-names>
            </name>
            <name>
              <surname>Reed</surname>
              <given-names>RB</given-names>
            </name>
            <name>
              <surname>Roche</surname>
              <given-names>AF</given-names>
            </name>
            <name>
              <surname>Moore</surname>
              <given-names>WM</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B22">
        <mixed-citation>22. Rosner B, Prineas J, Loggie JMH, Daniels SR - Blood pressure nomograms for children and adolescents, by height, sex, and age, in the United States. J Pediatr<bold> </bold>1993; 123: 871-86. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Blood pressure nomograms for children and adolescents, by height, sex, and age, in the United States</article-title>
          <source>J Pediatr</source>
          <date>
            <year>1993</year>
          </date>
          <fpage>871</fpage>
          <lpage>86</lpage>
          <volume>123</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Rosner</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Prineas</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Loggie</surname>
              <given-names>JMH</given-names>
            </name>
            <name>
              <surname>Daniels</surname>
              <given-names>SR</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B23">
        <mixed-citation>23. Report Of The Second Task Force On Blood Pressure Control In Children-1987 - National Heart, Lung and Blood Institute. Bethesda: Pediatrics 1987; 79: 1-25. </mixed-citation>
        <element-citation publication-type="journal">
          <source>Pediatrics</source>
          <date>
            <year>1987</year>
          </date>
          <fpage>1</fpage>
          <lpage>25</lpage>
          <volume>79</volume>
        </element-citation>
      </ref>
      <ref id="B24">
        <mixed-citation>24. Cates EM, Schlussel YR, James GD, Pickering TG - A validation study of the SpaceLabs 90207 ambulatory blood pressure monitor. J Amb Mon 1990; 3: 149-54. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>A validation study of the SpaceLabs 90207 ambulatory blood pressure monitor</article-title>
          <source>J Amb Mon</source>
          <date>
            <year>1990</year>
          </date>
          <fpage>149</fpage>
          <lpage>54</lpage>
          <volume>3</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Cates</surname>
              <given-names>EM</given-names>
            </name>
            <name>
              <surname>Schlussel</surname>
              <given-names>YR</given-names>
            </name>
            <name>
              <surname>James</surname>
              <given-names>GD</given-names>
            </name>
            <name>
              <surname>Pickering</surname>
              <given-names>TG</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B25">
        <mixed-citation>25. O'Brien E, Mee F, Atkins N, O'Malley K - Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society. J Hypertens 1991; 9: 573-4. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society</article-title>
          <source>J Hypertens</source>
          <date>
            <year>1991</year>
          </date>
          <fpage>573</fpage>
          <lpage>4</lpage>
          <volume>9</volume>
          <person-group person-group-type="author">
            <name>
              <surname>O'Brien</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Mee</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Atkins</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>O'Malley</surname>
              <given-names>K</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B26">
        <mixed-citation>26. O'Brien E, Mee F, Atkins N, O'Malley K - Accuracy of the SpaceLabs 90207, Del Mar Avionics, Pressurometer IV and Takeda TM-2420 ambulatory systems according to British and American criteria. J Hypertens 1991; 9(suppl): S332-3. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Accuracy of the SpaceLabs 90207, Del Mar Avionics, Pressurometer IV and Takeda TM-2420 ambulatory systems according to British and American criteria</article-title>
          <source>J Hypertens</source>
          <date>
            <year>1991</year>
          </date>
          <fpage>S332</fpage>
          <lpage>3</lpage>
          <volume>9</volume>
          <person-group person-group-type="author">
            <name>
              <surname>O'Brien</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Mee</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Atkins</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>O'Malley</surname>
              <given-names>K</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B27">
        <mixed-citation>27. Rosner B -<bold> </bold>Fundamentals of Biostatistics. 2nd ed. Boston: PWS Publishers, 1982: 246-62. </mixed-citation>
        <element-citation publication-type="book">
          <source>Fundamentals of Biostatistics</source>
          <date>
            <year>1982</year>
          </date>
          <fpage>246</fpage>
          <lpage>62</lpage>
          <person-group person-group-type="author">
            <name>
              <surname>Rosner</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B28">
        <mixed-citation>28. Timm NH - Multivariate Analysis with Applications in Education and Psychology.<bold> </bold>Monterrey. CA Brooks/Cole, 1975. </mixed-citation>
        <element-citation publication-type="book">
          <source>Multivariate Analysis with Applications in Education and Psychology</source>
          <date>
            <year>1975</year>
          </date>
          <person-group person-group-type="author">
            <name>
              <surname>Timm</surname>
              <given-names>NH</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B29">
        <mixed-citation>29. Peixoto Filho AJ, Mansoor GA, White WB - Effects of actual versus arbitrary awake and sleep times on analyses of 24-hour blood pressure. Am J Hypertens 1995; 8: 676-80. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Effects of actual versus arbitrary awake and sleep times on analyses of 24-hour blood pressure</article-title>
          <source>Am J Hypertens</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>676</fpage>
          <lpage>80</lpage>
          <volume>8</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Peixoto Filho</surname>
              <given-names>AJ</given-names>
            </name>
            <name>
              <surname>Mansoor</surname>
              <given-names>GA</given-names>
            </name>
            <name>
              <surname>White</surname>
              <given-names>WB</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B30">
        <mixed-citation>30. Rosansky SJ, Menachery SJ, Wagner CM, Jackson K - The effect of sleep intervals on analysis of 24-hour blood pressure data. Am J Hypertens 1995; 8: 672-5. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>The effect of sleep intervals on analysis of 24-hour blood pressure data</article-title>
          <source>Am J Hypertens</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>672</fpage>
          <lpage>5</lpage>
          <volume>8</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Rosansky</surname>
              <given-names>SJ</given-names>
            </name>
            <name>
              <surname>Menachery</surname>
              <given-names>SJ</given-names>
            </name>
            <name>
              <surname>Wagner</surname>
              <given-names>CM</given-names>
            </name>
            <name>
              <surname>Jackson</surname>
              <given-names>K</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B31">
        <mixed-citation>31. Gatzka CD, Schmieder RE - Improved classification of dippers by individualized analysis of ambulatory blood pressure profiles. Am J Hypertens<bold> </bold>1995; 8: 666-71. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Improved classification of dippers by individualized analysis of ambulatory blood pressure profiles</article-title>
          <source>Am J Hypertens</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>666</fpage>
          <lpage>71</lpage>
          <volume>8</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Gatzka</surname>
              <given-names>CD</given-names>
            </name>
            <name>
              <surname>Schmieder</surname>
              <given-names>RE</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B32">
        <mixed-citation>32. White WB - Blood pressure load and target organ effects in patients with essential hypertension. J Hypertens 1991;<bold> </bold>9(suppl 8): S39-S41. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Blood pressure load and target organ effects in patients with essential hypertension</article-title>
          <source>J Hypertens</source>
          <date>
            <year>1991</year>
          </date>
          <fpage>S39</fpage>
          <lpage>S41</lpage>
          <volume>9</volume>
          <person-group person-group-type="author">
            <name>
              <surname>White</surname>
              <given-names>WB</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B33">
        <mixed-citation>33. Prasad N, Macfadyen RJ, Ogston AS, Macdonald TM - Elevated blood pressure during the first two hours of ambulatory blood pressure monitoring: a study comparing consecutive twenty-four-hour monitoring periods.<bold> </bold>J Hypertens 1995; 13: 291-5. </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Elevated blood pressure during the first two hours of ambulatory blood pressure monitoring: a study comparing consecutive twenty-four-hour monitoring periods</article-title>
          <source>J Hypertens</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>291</fpage>
          <lpage>5</lpage>
          <volume>13</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Prasad</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Macfadyen</surname>
              <given-names>RJ</given-names>
            </name>
            <name>
              <surname>Ogston</surname>
              <given-names>AS</given-names>
            </name>
            <name>
              <surname>Macdonald</surname>
              <given-names>TM</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B34">
        <mixed-citation>34. Bursztyn M, Mekler J, Wachtel N, Ben-Ishay D - Siesta and Ambulatory blood pressure monitoring. Comparability of the afternoon nap and night sleep. Am J Hypertens 1994;<bold> </bold>7: 217-21<italic>.</italic> </mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Siesta and Ambulatory blood pressure monitoring: Comparability of the afternoon nap and night sleep</article-title>
          <source>Am J Hypertens</source>
          <date>
            <year>1994</year>
          </date>
          <fpage>217</fpage>
          <lpage>21</lpage>
          <volume>7</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Bursztyn</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Mekler</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Wachtel</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Ben-Ishay</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
    </ref-list>
  </back>
</article>
