<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "http://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="case-report" dtd-version="1.1" specific-use="sps-1.9" xml:lang="pt">
  <front>
    <journal-meta>
      <journal-id journal-id-type="nlm-ta">Arq Bras Cardiol</journal-id>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id specific-use="scielo-v3" pub-id-type="publisher-id">WP53jZhvJQxYFYBgKbRZBNS</article-id>
      <article-id specific-use="scielo-v2" pub-id-type="publisher-id">S0066-782X2025001000701</article-id>
      <article-id pub-id-type="other">00701</article-id>
      <article-id pub-id-type="doi">10.36660/abc.202250236</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Relato de Caso</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Primeira Interven&#231;&#227;o Coron&#225;ria Percut&#226;nea de Alto Risco do Brasil com Suporte Hemodin&#226;mico de Dispositivo Puls&#225;til Percut&#226;neo: Um Relato de Caso</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0003-0633-3853</contrib-id>
          <name>
            <surname>Nicolau</surname>
            <given-names>Andr&#233; M.</given-names>
          </name>
          <role>Concep&#231;&#227;o e desenho da pesquisa e Reda&#231;&#227;o do manuscrito</role>
          <role>Obten&#231;&#227;o de dados</role>
          <role>Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do</role>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Melo</surname>
            <given-names>Pedro H. M. C. de</given-names>
          </name>
          <role>Concep&#231;&#227;o e desenho da pesquisa e Reda&#231;&#227;o do manuscrito</role>
          <role>Obten&#231;&#227;o de dados</role>
          <role>Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do</role>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Oliveira</surname>
            <given-names>Lucas Aguiar Alencar de</given-names>
          </name>
          <role>Concep&#231;&#227;o e desenho da pesquisa e Reda&#231;&#227;o do manuscrito</role>
          <role>Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do</role>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Bergo</surname>
            <given-names>Rafael</given-names>
          </name>
          <role>Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do</role>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Kleinsorge</surname>
            <given-names>Thiago A.</given-names>
          </name>
          <role>Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do</role>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Godinho</surname>
            <given-names>Roger Renault</given-names>
          </name>
          <role>Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do</role>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-6260-9626</contrib-id>
          <name>
            <surname>Brito</surname>
            <given-names>F&#225;bio S&#226;ndoli de</given-names>
            <suffix>Jr</suffix>
          </name>
          <role>Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do</role>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
          <xref ref-type="aff" rid="aff2">
            <sup>2</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Abizaid</surname>
            <given-names>Alexandre A.</given-names>
          </name>
          <role>Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do</role>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Campos</surname>
            <given-names>Carlos de Magalh&#227;es</given-names>
          </name>
          <role>Concep&#231;&#227;o e desenho da pesquisa e Reda&#231;&#227;o do manuscrito</role>
          <role>Obten&#231;&#227;o de dados</role>
          <role>Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do</role>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
          <xref ref-type="corresp" rid="c1"/>
        </contrib>
        <aff id="aff1">
          <label>1</label>
          <institution content-type="orgname">Hospital das Cl&#237;nicas da Faculdade de Medicina da Universidade de S&#227;o Paulo</institution>
          <institution content-type="orgdiv1">Instituto do Cora&#231;&#227;o</institution>
          <addr-line>
            <named-content content-type="city">S&#227;o Paulo</named-content>
            <named-content content-type="state">SP</named-content>
          </addr-line>
          <country country="BR">Brasil</country>
          <institution content-type="original">Instituto do Cora&#231;&#227;o do Hospital das Cl&#237;nicas da Faculdade de Medicina da Universidade de S&#227;o Paulo, S&#227;o Paulo, SP &#8211; Brasil</institution>
        </aff>
        <aff id="aff2">
          <label>2</label>
          <institution content-type="orgname">Hospital S&#237;rio-Liban&#234;s</institution>
          <addr-line>
            <named-content content-type="city">S&#227;o Paulo</named-content>
            <named-content content-type="state">SP</named-content>
          </addr-line>
          <country country="BR">Brasil</country>
          <institution content-type="original">Hospital S&#237;rio-Liban&#234;s, S&#227;o Paulo, SP &#8211; Brasil</institution>
        </aff>
      </contrib-group>
      <author-notes>
        <corresp id="c1"><label>Correspond&#234;ncia:</label><bold>Carlos de Magalh&#227;es Campos</bold> &#8226; Instituto do Cora&#231;&#227;o do Hospital das Cl&#237;nicas da Faculdade de Medicina da Universidade de S&#227;o Paulo &#8211; Avenida Dr. Eneas de Carvalho Aguiar, 44. CEP <postal-code>01246-903</postal-code>, S&#227;o Paulo, SP &#8211; Brasil E-mail: <email>carlosacampos1@gmail.com</email> </corresp>
        <fn fn-type="coi-statement">
          <label>Potencial conflito de interesse</label>
          <p>N&#227;o h&#225; conflito com o presente artigo</p>
        </fn>
        <fn fn-type="edited-by">
          <label>Editor respons&#225;vel pela revis&#227;o:</label>
          <p>Henrique Ribeiro</p>
        </fn>
      </author-notes>
      <pub-date date-type="pub" publication-format="electronic">
        <day>15</day>
        <month>12</month>
        <year>2025</year>
      </pub-date>
      <pub-date date-type="collection" publication-format="electronic">
        <year>2025</year>
      </pub-date>
      <volume>122</volume>
      <issue>10</issue>
      <elocation-id>e20250236</elocation-id>
      <history>
        <date date-type="received">
          <day>14</day>
          <month>04</month>
          <year>2025</year>
        </date>
        <date date-type="rev-recd">
          <day>27</day>
          <month>06</month>
          <year>2025</year>
        </date>
        <date date-type="accepted">
          <day>28</day>
          <month>07</month>
          <year>2025</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/" xml:lang="en">
          <license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution License</license-p>
        </license>
      </permissions>
      <abstract>
        <title>Resumo</title>
        <p>A interven&#231;&#227;o coron&#225;ria percut&#226;nea (ICP) &#233; o m&#233;todo de revasculariza&#231;&#227;o coronariana mais utilizada no mundo, mesmo em casos de alta complexidade anat&#244;mica. No entanto, a crescente complexidade elevou os riscos associados ao procedimento. Dispositivos de assist&#234;ncia circulat&#243;ria mec&#226;nica (DACMs), como o iVAC 2L, t&#234;m sido empregados para suporte hemodin&#226;mico em ICPs de alto risco.</p>
        <p>Descrevemos o primeiro caso no Brasil de ICP realizada com suporte do iVAC 2L, um DACM puls&#225;til. O paciente, um homem de 81 anos, com angina classe funcional III e les&#245;es graves em tronco de coron&#225;ria esquerda (TCE), descendente anterior (DA) e circunflexa (CX), associada a calcifica&#231;&#227;o extensa. O procedimento foi realizado com suporte do iVAC 2L e realizada ICP com implante de stent em TCE, DA e CX. Todo o procedimento ocorreu sem necessidade de drogas vasoativas e o dispositivo foi removido sem complica&#231;&#245;es vasculares.</p>
        <p>A ICP de alto risco tem se tornado cada vez mais comum, muitas vezes exigindo suporte mec&#226;nico ventricular. O iVAC 2L apresenta vantagens como fluxo puls&#225;til e facilidade de implante, sendo uma alternativa ao bal&#227;o intra-a&#243;rtico e ao Impella. O relato destaca a possibilidade do uso do iVAC 2L no cen&#225;rio nacional, ampliando as op&#231;&#245;es terap&#234;uticas para pacientes de alto risco.</p>
      </abstract>
      <kwd-group xml:lang="pt">
        <title>Palavras-chave</title>
        <kwd>Interven&#231;&#227;o Coron&#225;ria Percut&#226;nea</kwd>
        <kwd>Cora&#231;&#227;o Auxiliar</kwd>
        <kwd>Doen&#231;a da Art&#233;ria Coronariana</kwd>
      </kwd-group>
      <funding-group>
        <funding-statement><bold>Fontes de financiamento</bold> O presente estudo n&#227;o teve fontes de financiamento externas.</funding-statement>
      </funding-group>
      <counts>
        <fig-count count="14"/>
        <table-count count="2"/>
        <equation-count count="0"/>
        <ref-count count="16"/>
      </counts>
    </article-meta>
  </front>
  <body>
    <sec sec-type="intro">
      <title>Introdu&#231;&#227;o</title>
      <p>A interven&#231;&#227;o coron&#225;ria percut&#226;nea (ICP) &#233; o m&#233;todo de revasculariza&#231;&#227;o mais realizado, mesmo em casos de alta complexidade anat&#244;mica, particularmente em pacientes de alto risco cir&#250;rgico<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B2">2</xref></sup> Entretanto, com o aumento da complexidade anat&#244;mica, associado ao envelhecimento populacional e aumento da incid&#234;ncia de comorbidades, observa-se um aumento do perfil de risco das ICP.<sup><xref ref-type="bibr" rid="B3">3</xref>&#8211;<xref ref-type="bibr" rid="B5">5</xref></sup></p>
      <p>Neste contexto, os dispositivos de assist&#234;ncia circulat&#243;ria mec&#226;nica (DACM) reconhecidamente promovem melhora dos par&#226;metros hemodin&#226;micos<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B7">7</xref></sup> e s&#227;o recomendados para suporte circulat&#243;rio mec&#226;nico tempor&#225;rio no contexto de ICP de alto risco.<sup><xref ref-type="bibr" rid="B8">8</xref>&#8211;<xref ref-type="bibr" rid="B11">11</xref></sup></p>
      <p>O dispositivo iVAC 2L (<italic>Pulsecath BV, Amsterdam, The Netherlands)</italic> &#233; um DACM de inser&#231;&#227;o retr&#243;grada pela art&#233;ria femoral. O dispositivo consiste em uma v&#225;lvula bidirecional conectada a uma membrana extracorp&#243;rea por uma c&#226;nula de 17Fr. O sangue &#233; aspirado do ventr&#237;culo pela ponta do cateter durante a s&#237;stole at&#233; a membrana e, durante a di&#225;stole, a membrana ejeta o sangue na aorta ascendente pela v&#225;lvula bidirecional (<xref ref-type="fig" rid="f1">Figura 1</xref>) A movimenta&#231;&#227;o da membrana ocorre &#224;s custas da mobiliza&#231;&#227;o de g&#225;s h&#233;lio pelo console de bal&#227;o intra-a&#243;rtico (<xref ref-type="fig" rid="f6">V&#237;deo 1</xref>), que comanda o funcionamento do dispositivo. A ponta do cateter &#233; posicionada retrogradamente abaixo da valva a&#243;rtica e dentro do ventr&#237;culo esquerdo (<xref ref-type="fig" rid="f1">Figura 1</xref>). Sob condi&#231;&#245;es ideais (frequ&#234;ncia card&#237;aca 70 - 80 bpm) o d&#233;bito card&#237;aco adicional &#233; de at&#233; 2.0L/min, com fluxo puls&#225;til. A seguran&#231;a e o funcionamento do iVAC 2L foram reportadas previamente.<sup><xref ref-type="bibr" rid="B12">12</xref>,<xref ref-type="bibr" rid="B13">13</xref></sup></p>
      <fig id="f1">
        <label>Figura 1</label>
        <caption>
          <title>1A) Posicionamento do dispositivo iVAC 2.0 com ponta do ventr&#237;culo esquerdo (seta cheia) e v&#225;lvula direcional na aorta ascendente (seta pontilhada).</title>
          <p>Fio guia 0.035'auxilia reconhecimento da posi&#231;&#227;o do seio a&#243;rtico (marcada com tri&#226;ngulo). 1B) Dispositivo iVAC 2.0.</p>
        </caption>
        <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf01.tif"/></fig>
      <fig id="f6">
        <label>V&#237;deo 1</label>
        <caption>
          <title>Dispon&#237;vel em: <ext-link ext-link-type="uri" xlink:href="http://abccardiol.org/supplementary-material/2025/12210/2025-0236_RC_Video_1.mp4">http://abccardiol.org/supplementary-material/2025/12210/2025-0236_RC_Video_1.mp4</ext-link> </title>
        </caption>
        <media id="mf6" mime-subtype="mp4" mimetype="video" xlink:href="https://minio.scielo.br/documentstore/1678-4170/WP53jZhvJQxYFYBgKbRZBNS/5a14afb00d6fc9811ba29b68d51b940df7153ee2.mp4"> </media>
        <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf02.tif"/></fig>
      <p>Apresentaremos o primeiro caso realizado no Brasil de ICP complexa de alto risco realizada com suporte do dispositivo iVAC 2L.</p>
    </sec>
    <sec sec-type="cases">
      <title>Caso Cl&#237;nico</title>
      <p>Reportamos o caso de um homem de 81 anos, hipertenso e diab&#233;tico, encaminhado ao nosso servi&#231;o por dispneia e angina classe III. Foi realizada avalia&#231;&#227;o funcional com cintilografia que demonstrou isquemia na parede anterior e anterosseptal, al&#233;m de queda da press&#227;o arterial no pico do esfor&#231;o e fra&#231;&#227;o de eje&#231;&#227;o do ventr&#237;culo esquerdo de 34%. Indicou-se ent&#227;o cateterismo card&#237;aco, que revelou les&#227;o em tronco de coron&#225;ria esquerda (TCE) (80%), descendente anterior (DA) (les&#245;es de 70 e 80% em ter&#231;os proximal e m&#233;dio) e art&#233;ria circunflexa (CX) (70% em ter&#231;o proximal), associada a extensa calcifica&#231;&#227;o coron&#225;ria (<xref ref-type="fig" rid="f2">Figura 2</xref>) e Syntax Score 32. O caso foi discutido em "Heart Team" e foi optado por tratamento percut&#226;neo ap&#243;s pondera&#231;&#227;o de alto risco cir&#250;rgico por Euroscore II 7.74%, STS 5.82% e fragilidade cl&#237;nica avaliada por equipe multidisciplinar.</p>
      <fig id="f2">
        <label>Figura 2</label>
        <caption>
          <title>Cateterismo card&#237;aco demonstrando les&#245;es de 80% em tronco de coron&#225;ria esquerda (TCE), 80% em DA e 70% em Cx.</title>
        </caption>
        <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf03.tif"/></fig>
      <p>O procedimento foi iniciado com pun&#231;&#227;o femoral seguida de arteriografia bilateral (<xref ref-type="fig" rid="f3">Figura 3</xref>) para decis&#227;o da melhor estrat&#233;gia. Ambas as art&#233;rias femorais comuns apresentavam calibres adequados para acomodar o introdutor do dispositivo iVAC 2L. Observada les&#227;o ateroscler&#243;tica importante no ter&#231;o distal da femoral comum direita, sendo optado por realizar o posicionamento do dispositivo iVAC 2L pela art&#233;ria femoral comum esquerda.</p>
      <fig id="f3">
        <label>Figura 3</label>
        <caption>
          <title>Arteriografia femoral e inguinal esquerdas.</title>
          <p>Figura 3A: arteriografia femoral esquerda demonstrando bom calibre da via. Figura 3B: arteriografia il&#237;aca esquerda demonstrando bom calibre da via e importante tortuosidade em il&#237;aca comum.</p>
        </caption>
        <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf04.tif"/></fig>
      <p>Realizou-se pr&#233;-fechamento da art&#233;ria femoral esquerda com dois dispositivos <italic>Perclose</italic> proglide e inser&#231;&#227;o de introdutor 18F hidrof&#237;lico, por fio-guia 0,035&#8243; de alto suporte ("<italic>Amplatz Super Stiff")</italic>. Pela art&#233;ria femoral direita, utilizou-se um fio-guia 0,035&#8243; posicionado no seio n&#227;o coron&#225;rio para marcar o n&#237;vel da valva a&#243;rtica. Na sequ&#234;ncia, avan&#231;ou-se o dispositivo iVAC 2L posicionando sua ponta no ventr&#237;culo esquerdo, 2 cm abaixo da valva a&#243;rtica, mantendo a v&#225;lvula bidirecional na aorta ascendente (<xref ref-type="fig" rid="f1">Figura 1</xref>). O dispositivo foi conectado ao console do BIA (bal&#227;o intra-a&#243;rtico), configurado para disparo por ECG, com insufla&#231;&#227;o m&#225;xima e disparo 1:1, fornecendo um d&#233;bito adicional estimado em torno de 2.0L, visto frequ&#234;ncia card&#237;aca do paciente em torno de 70-80bpm (<xref ref-type="fig" rid="f7">V&#237;deo 2</xref>).</p>
      <fig id="f7">
        <label>V&#237;deo 2</label>
        <caption>
          <title>Dispon&#237;vel em: <ext-link ext-link-type="uri" xlink:href="http://abccardiol.org/supplementary-material/2025/12210/2025-0236_RC_Video_2.mp4">http://abccardiol.org/supplementary-material/2025/12210/2025-0236_RC_Video_2.mp4</ext-link> </title>
        </caption>
        <media id="mf7" mime-subtype="mp4" mimetype="video" xlink:href="https://minio.scielo.br/documentstore/1678-4170/WP53jZhvJQxYFYBgKbRZBNS/acd37adddddbe8533e7dedc50dc425009ebcc8e8.mp4"> </media>
        <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf05.tif"/></fig>
      <p>Utilizamos cateter EBU 3.5 7Fr para cateteriza&#231;&#227;o da coron&#225;ria esquerda. Pela presen&#231;a de les&#227;o gravemente esten&#243;tica, realizada pr&#233;-dilata&#231;&#227;o para permitir avalia&#231;&#227;o com ultrassom intracoron&#225;rio (USIC), que demonstrou &#225;rea luminal m&#237;nima de 1,88mm<sup>2</sup>, placa fibrolip&#237;dica e calcifica&#231;&#227;o importante, al&#233;m de ulcera&#231;&#227;o em TCE e ponte mioc&#225;rdica no segmento distal da art&#233;ria (<xref ref-type="fig" rid="f4">Figura 4</xref>). Foi realizado, preparo da les&#227;o com bal&#245;es dedicados (<italic>Cutting Balloon</italic> e bal&#227;o n&#227;o complacente<italic>)</italic>, com resultado adequado comprovado por USIC. A seguir, implantamos Stents farmacol&#243;gicos em DA m&#233;dia, CX ostial com m&#237;nima protrus&#227;o para o tronco, e DA proximal com extens&#227;o para o tronco, conforme t&#233;cnica de "<italic>Mini-Crush"</italic>. Realizada p&#243;s-dilata&#231;&#227;o dos stents, e ajuste de carina com t&#233;cnica de "<italic>Kissing-balloon".</italic> Realizado USIC de controle com adequada expans&#227;o e aposi&#231;&#227;o das hastes, sem complica&#231;&#245;es (<xref ref-type="fig" rid="f5">Figura 5</xref>). Todo o procedimento foi realizado sob seda&#231;&#227;o consciente, sem uso de droga vasoativa. Ap&#243;s o procedimento, o dispositivo foi retirado e realizada hemostasia com perclose, conforme mencionado. A arteriografia final n&#227;o demonstrou complica&#231;&#245;es vasculares (<xref ref-type="fig" rid="f5">Figura 5</xref>).<sup><xref ref-type="bibr" rid="B8">8</xref></sup></p>
      <fig id="f4">
        <label>Figura 4</label>
        <caption>
          <title>Avalia&#231;&#227;o com ultrassom intracoron&#225;rio (USIC) pr&#233; implante de <italic>Stent</italic> com fio-guia posicionado em segmento distal da art&#233;ria descendente anterior.</title>
          <p>4A) corte longititudinal (<italic>Long view</italic>) da coron&#225;ria descendente anterior at&#233; o tronco da coron&#225;ria esquerda. 4B) presen&#231;a de &#250;lcera em TCE, marcada com "#", demonstrando comunica&#231;&#227;o da les&#227;o com o l&#250;men. 4C) Calcifica&#231;&#227;o extensa em descendente anterior, com &#226;ngulo de calcifica&#231;&#227;o &gt;270&#176; reconhecido pela sobra ac&#250;stica posterior ausente apenas entre 1 e 4 horas. 4D) &#193;rea luminal m&#237;nima em descendente anterior com 1.88mm<sup><xref ref-type="bibr" rid="B2">2</xref></sup>. 4E) Presen&#231;a de ponta mioc&#225;rdica em por&#231;&#227;o distal do segmento avaliado (marcado com "*"), servindo como refer&#234;ncia distal para posicionamento de Stent. Sinal da "meia-lua" ou <italic>Half-moon sign</italic>.</p>
        </caption>
        <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf06.tif"/></fig>
      <fig id="f5">
        <label>Figura 5</label>
        <caption>
          <title>Resultado final angiogr&#225;fico e ultrassonogr&#225;fico.</title>
          <p>5A) Resultado final com t&#233;cnica de Mini-Crush TCE-DA e Cx. 5B) Avalia&#231;&#227;o final de USIC com &#225;rea luminal m&#237;nima intra-stent 6.69mm<sup>2</sup>. Figura 5C: Arteriografia femoral esquerda final sem complica&#231;&#245;es.</p>
        </caption>
        <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf07.tif"/></fig>
    </sec>
    <sec sec-type="discussion">
      <title>Discuss&#227;o</title>
      <p>ICPs de alto risco vem se tornando cada vez mais frequentes e com melhores resultados.<sup><xref ref-type="bibr" rid="B3">3</xref>&#8211;<xref ref-type="bibr" rid="B5">5</xref></sup> Neste contexto, diversos DACM foram desenvolvidos.<sup><xref ref-type="bibr" rid="B14">14</xref></sup> Historicamente, o BIA tem sido utilizado na pr&#225;tica cl&#237;nica para suporte mec&#226;nico em ICPs de alto risco. A evid&#234;ncia proveniente de ensaio cl&#237;nico randomizado neste contexto falhou em demonstrar benef&#237;cio em redu&#231;&#227;o de eventos cardiovasculares maiores intra-hospitalares, apesar de an&#225;lises de longo prazo apontarem para poss&#237;vel, embora especulativo, benef&#237;cio de longo prazo.<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B15">15</xref></sup> Assim, embora o BIA ofere&#231;a suporte mec&#226;nico e melhora da perfus&#227;o coron&#225;ria e cerebral, o modesto ganho de d&#233;bito card&#237;aco e a falta de evid&#234;ncia de benef&#237;cios cardiovasculares levou a sua n&#227;o recomenda&#231;&#227;o pelas diretrizes e consensos.<sup><xref ref-type="bibr" rid="B2">2</xref>,<xref ref-type="bibr" rid="B8">8</xref></sup></p>
      <p>O funcionamento e seguran&#231;a do dispositivo iVAC 2L foram demonstrados em estudos pr&#233;vios,<sup><xref ref-type="bibr" rid="B12">12</xref>,<xref ref-type="bibr" rid="B13">13</xref>,<xref ref-type="bibr" rid="B16">16</xref></sup> fornecendo um d&#233;bito card&#237;aco de at&#233; 2.0L/min, cerca de 3-4x o d&#233;bito fornecido pelo BIA (<xref ref-type="table" rid="t1">Tabela 1</xref>). Quando comparado aos dispositivos de fluxo cont&#237;nuo como <italic>Impella</italic> e ECMO, apresenta como diferenciais o fluxo puls&#225;til possivelmente mais fisiol&#243;gico, a facilidade no implante e o uso de console de bal&#227;o j&#225; dispon&#237;vel em diversos centros, dispensando um console dedicado. Se comparado a ECMO V-A, o iVAC apresenta como vantagem, assim como o Impella e o BIA, a descompress&#227;o do ventr&#237;culo esquerdo e diminui&#231;&#227;o da resist&#234;ncia vascular sist&#234;mica. Como desvantagens, destaca-se o perfil de 18F (frente os 14F do Impella CP) e o menor suporte (at&#233; 2L frente aos 4.3L do Impella ou at&#233; 10L/min da ECMO V-A) (<xref ref-type="table" rid="t1">Tabela 1</xref>).</p>
      <table-wrap id="t1">
        <label>Tabela 1</label>
        <caption>
          <title>Compara&#231;&#227;o entre os dispositivos iVAC 2L, BIA, Impella e ECMO V-A</title>
        </caption>
        <table frame="hsides" rules="groups">
          <colgroup width="20%">
            <col/>
            <col/>
            <col/>
            <col/>
            <col/>
          </colgroup>
          <thead style="border-top: thin solid; border-bottom: thin solid; border-color: #000000">
            <tr style="background-color:#76B4CF">
              <th align="left" valign="middle"/>
              <th align="center" valign="middle">iVAC 2L</th>
              <th align="center" valign="middle">BIA</th>
              <th align="center" valign="middle">Impella</th>
              <th align="center" valign="middle">ECMO V-A</th>
            </tr>
          </thead>
          <tbody style="border-bottom: thin solid; border-color: #000000">
            <tr>
              <td align="left" valign="middle">D&#233;bito adicional</td>
              <td align="center" valign="middle">2,0L/min</td>
              <td align="center" valign="middle">0,3-0,5L/min</td>
              <td align="center" valign="middle">2,5-5,5L/min</td>
              <td align="center" valign="middle">At&#233; 7L/min</td>
            </tr>
            <tr style="background-color:#C7DFEC">
              <td align="left" valign="middle">Acesso</td>
              <td align="center" valign="middle">Femoral 18Fr</td>
              <td align="center" valign="middle">Femoral 7-8Fr</td>
              <td align="center" valign="middle">13-14Fr</td>
              <td align="center" valign="middle">14-19Fr Arterial<break/> 17-21Fr ECMO</td>
            </tr>
            <tr>
              <td align="left" valign="middle">Mecanismo</td>
              <td align="center" valign="middle">Membrana extracorp&#243;rea</td>
              <td align="center" valign="middle">Contrapulsa&#231;&#227;o</td>
              <td align="center" valign="middle">Bomba microaxial</td>
              <td align="center" valign="middle">Bomba centr&#237;fuga</td>
            </tr>
            <tr style="background-color:#C7DFEC">
              <td align="left" valign="middle">Sincronia com ritmo card&#237;aco</td>
              <td align="center" valign="middle">Sim</td>
              <td align="center" valign="middle">Sim</td>
              <td align="center" valign="middle">N&#227;o</td>
              <td align="center" valign="middle">N&#227;o</td>
            </tr>
            <tr>
              <td align="left" valign="middle">P&#243;s-carga</td>
              <td align="center" valign="middle">Diminui</td>
              <td align="center" valign="middle">Diminui</td>
              <td align="center" valign="middle">Diminui</td>
              <td align="center" valign="middle">Aumenta</td>
            </tr>
          </tbody>
        </table>
      </table-wrap>
    </sec>
    <sec sec-type="data-availability" specific-use="data-in-article">
      <title>Disponibilidade de Dados</title>
      <p>Os conte&#250;dos subjacentes ao texto da pesquisa est&#227;o contidos no manuscrito.</p>
    </sec>
  </body>
  <back>
    <fn-group>
      <fn fn-type="financial-disclosure" id="fn1">
        <label>Fontes de financiamento</label>
        <p>O presente estudo n&#227;o teve fontes de financiamento externas.</p>
      </fn>
      <fn fn-type="other" id="fn2">
        <label>Vincula&#231;&#227;o acad&#234;mica</label>
        <p>N&#227;o h&#225; vincula&#231;&#227;o deste estudo a programas de p&#243;s-gradua&#231;&#227;o.</p>
      </fn>
      <fn fn-type="other" id="fn3">
        <label>Aprova&#231;&#227;o &#233;tica e consentimento informado</label>
        <p>O paciente forneceu consentimento informado por escrito para a realiza&#231;&#227;o do procedimento e para o uso de suas imagens e dados cl&#237;nicos com fins cient&#237;ficos e de publica&#231;&#227;o.</p>
      </fn>
      <fn fn-type="other" id="fn4">
        <label>Uso de Intelig&#234;ncia Artificial</label>
        <p>Os autores n&#227;o utilizaram ferramentas de intelig&#234;ncia artificial no desenvolvimento deste trabalho.</p>
      </fn>
    </fn-group>
    <ref-list>
      <title>Refer&#234;ncias</title>
      <ref id="B1">
        <label>1</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Vrints</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Andreotti</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Koskinas</surname>
              <given-names>KC</given-names>
            </name>
            <name>
              <surname>Rossello</surname>
              <given-names>X</given-names>
            </name>
            <name>
              <surname>Adamo</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Ainslie</surname>
              <given-names>J</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>2024 ESC Guidelines for the Management of Chronic Coronary Syndromes</article-title>
          <source>Eur Heart J</source>
          <year>2024</year>
          <volume>45</volume>
          <issue>36</issue>
          <fpage>3415</fpage>
          <lpage>3537</lpage>
          <pub-id pub-id-type="doi">10.1093/eurheartj/ehae177</pub-id>
        </element-citation>
        <mixed-citation>1 Vrints C, Andreotti F, Koskinas KC, Rossello X, Adamo M, Ainslie J, et al. 2024 ESC Guidelines for the Management of Chronic Coronary Syndromes. Eur Heart J. 2024;45(36):3415-537. doi: 10.1093/eurheartj/ehae177.</mixed-citation>
      </ref>
      <ref id="B2">
        <label>2</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Lawton</surname>
              <given-names>JS</given-names>
            </name>
            <name>
              <surname>Tamis-Holland</surname>
              <given-names>JE</given-names>
            </name>
            <name>
              <surname>Bangalore</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Bates</surname>
              <given-names>ER</given-names>
            </name>
            <name>
              <surname>Beckie</surname>
              <given-names>TM</given-names>
            </name>
            <name>
              <surname>Bischoff</surname>
              <given-names>JM</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines</article-title>
          <source>Circulation</source>
          <year>2022</year>
          <volume>145</volume>
          <issue>3</issue>
          <fpage>e18</fpage>
          <lpage>e114</lpage>
          <pub-id pub-id-type="doi">10.1161/CIR.0000000000001038</pub-id>
        </element-citation>
        <mixed-citation>2 Lawton JS, Tamis-Holland JE, Bangalore S, Bates ER, Beckie TM, Bischoff JM, et al. 2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2022;145(3):e18-e114. doi: 10.1161/CIR.0000000000001038.</mixed-citation>
      </ref>
      <ref id="B3">
        <label>3</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Asano</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Ono</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Dai</surname>
              <given-names>Z</given-names>
            </name>
            <name>
              <surname>Saito</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Kanie</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Takaoka</surname>
              <given-names>Y</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Temporal Trends in Clinical Outcomes after Percutaneous Coronary Intervention: A Systematic Review of 66,327 Patients from 25 All-Comers Trials</article-title>
          <source>EuroIntervention</source>
          <year>2022</year>
          <volume>17</volume>
          <issue>16</issue>
          <fpage>1318</fpage>
          <lpage>1329</lpage>
          <pub-id pub-id-type="doi">10.4244/EIJ-D-21-00192</pub-id>
        </element-citation>
        <mixed-citation>3 Asano T, Ono M, Dai Z, Saito A, Kanie T, Takaoka Y, et al. Temporal Trends in Clinical Outcomes after Percutaneous Coronary Intervention: A Systematic Review of 66,327 Patients from 25 All-Comers Trials. EuroIntervention. 2022;17(16):1318-29. doi: 10.4244/EIJ-D-21-00192.</mixed-citation>
      </ref>
      <ref id="B4">
        <label>4</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Kinnaird</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Gallagher</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Farooq</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>Protty</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Back</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Devlin</surname>
              <given-names>P</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Temporal Trends in In-Hospital Outcomes Following Unprotected Left-Main Percutaneous Coronary Intervention: An Analysis of 14 522 Cases from British Cardiovascular Intervention Society Database 2009 to 2017</article-title>
          <source>Circ Cardiovasc Interv</source>
          <year>2023</year>
          <volume>16</volume>
          <issue>1</issue>
          <elocation-id>e012350</elocation-id>
          <pub-id pub-id-type="doi">10.1161/CIRCINTERVENTIONS.122.012350</pub-id>
        </element-citation>
        <mixed-citation>4 Kinnaird T, Gallagher S, Farooq V, Protty M, Back L, Devlin P, et al. Temporal Trends in In-Hospital Outcomes Following Unprotected Left-Main Percutaneous Coronary Intervention: An Analysis of 14 522 Cases from British Cardiovascular Intervention Society Database 2009 to 2017. Circ Cardiovasc Interv. 2023;16(1):e012350. doi: 10.1161/CIRCINTERVENTIONS.122.012350.</mixed-citation>
      </ref>
      <ref id="B5">
        <label>5</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Alzahrani</surname>
              <given-names>AH</given-names>
            </name>
            <name>
              <surname>Alabbadi</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Itagaki</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Egorova</surname>
              <given-names>N</given-names>
            </name>
          </person-group>
          <article-title>Temporal Trend in Revascularization for Patients with Ischemic Cardiomyopathy and Multivessel Coronary Artery Disease</article-title>
          <source>J Am Heart Assoc</source>
          <year>2024</year>
          <volume>13</volume>
          <issue>3</issue>
          <elocation-id>e032212</elocation-id>
          <pub-id pub-id-type="doi">10.1161/JAHA.123.032212</pub-id>
        </element-citation>
        <mixed-citation>5 Alzahrani AH, Alabbadi S, Itagaki S, Egorova N. Temporal Trend in Revascularization for Patients with Ischemic Cardiomyopathy and Multivessel Coronary Artery Disease. J Am Heart Assoc. 2024;13(3):e032212. doi: 10.1161/JAHA.123.032212.</mixed-citation>
      </ref>
      <ref id="B6">
        <label>6</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Perera</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Stables</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Clayton</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>De Silva</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Lumley</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Clack</surname>
              <given-names>L</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Long-Term Mortality Data from the Balloon Pump-Assisted Coronary Intervention Study (BCIS-1): A Randomized, Controlled Trial of Elective Balloon Counterpulsation during High-Risk Percutaneous Coronary Intervention</article-title>
          <source>Circulation</source>
          <year>2013</year>
          <volume>127</volume>
          <issue>2</issue>
          <fpage>207</fpage>
          <lpage>212</lpage>
          <pub-id pub-id-type="doi">10.1161/CIRCULATIONAHA.112.132209</pub-id>
        </element-citation>
        <mixed-citation>6 Perera D, Stables R, Clayton T, De Silva K, Lumley M, Clack L, et al. Long-Term Mortality Data from the Balloon Pump-Assisted Coronary Intervention Study (BCIS-1): A Randomized, Controlled Trial of Elective Balloon Counterpulsation during High-Risk Percutaneous Coronary Intervention. Circulation. 2013;127(2):207-12. doi: 10.1161/CIRCULATIONAHA.112.132209.</mixed-citation>
      </ref>
      <ref id="B7">
        <label>7</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>O&#8217;Neill</surname>
              <given-names>WW</given-names>
            </name>
            <name>
              <surname>Kleiman</surname>
              <given-names>NS</given-names>
            </name>
            <name>
              <surname>Moses</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Henriques</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>Dixon</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Massaro</surname>
              <given-names>J</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>A Prospective, Randomized Clinical Trial of Hemodynamic Support with Impella 2.5 versus Intra-Aortic Balloon Pump in Patients Undergoing High-Risk Percutaneous Coronary Intervention: The PROTECT II Study</article-title>
          <source>Circulation</source>
          <year>2012</year>
          <volume>126</volume>
          <issue>14</issue>
          <fpage>1717</fpage>
          <lpage>1727</lpage>
          <pub-id pub-id-type="doi">10.1161/CIRCULATIONAHA.112.098194</pub-id>
        </element-citation>
        <mixed-citation>7 O&#8217;Neill WW, Kleiman NS, Moses J, Henriques JP, Dixon S, Massaro J, et al. A Prospective, Randomized Clinical Trial of Hemodynamic Support with Impella 2.5 versus Intra-Aortic Balloon Pump in Patients Undergoing High-Risk Percutaneous Coronary Intervention: The PROTECT II Study. Circulation. 2012;126(14):1717-27. doi: 10.1161/CIRCULATIONAHA.112.098194.</mixed-citation>
      </ref>
      <ref id="B8">
        <label>8</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Chieffo</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Dudek</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Hassager</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Combes</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Gramegna</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Halvorsen</surname>
              <given-names>S</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Joint EAPCI/ACVC Expert Consensus Document on Percutaneous Ventricular Assist Devices</article-title>
          <source>Eur Heart J Acute Cardiovasc Care</source>
          <year>2021</year>
          <volume>10</volume>
          <issue>5</issue>
          <fpage>570</fpage>
          <lpage>583</lpage>
          <pub-id pub-id-type="doi">10.1093/ehjacc/zuab015</pub-id>
        </element-citation>
        <mixed-citation>8 Chieffo A, Dudek D, Hassager C, Combes A, Gramegna M, Halvorsen S, et al. Joint EAPCI/ACVC Expert Consensus Document on Percutaneous Ventricular Assist Devices. Eur Heart J Acute Cardiovasc Care. 2021;10(5):570-83. doi: 10.1093/ehjacc/zuab015.</mixed-citation>
      </ref>
      <ref id="B9">
        <label>9</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>M&#248;ller</surname>
              <given-names>JE</given-names>
            </name>
            <name>
              <surname>Engstr&#248;m</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Jensen</surname>
              <given-names>LO</given-names>
            </name>
            <name>
              <surname>Eiskj&#230;r</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Mangner</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Polzin</surname>
              <given-names>A</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Microaxial Flow Pump or Standard Care in Infarct-Related Cardiogenic Shock</article-title>
          <source>N Engl J Med</source>
          <year>2024</year>
          <volume>390</volume>
          <issue>15</issue>
          <fpage>1382</fpage>
          <lpage>1393</lpage>
          <pub-id pub-id-type="doi">10.1056/NEJMoa2312572</pub-id>
        </element-citation>
        <mixed-citation>9 M&#248;ller JE, Engstr&#248;m T, Jensen LO, Eiskj&#230;r H, Mangner N, Polzin A, et al. Microaxial Flow Pump or Standard Care in Infarct-Related Cardiogenic Shock. N Engl J Med. 2024;390(15):1382-93. doi: 10.1056/NEJMoa2312572.</mixed-citation>
      </ref>
      <ref id="B10">
        <label>10</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Elbadawi</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Elgendy</surname>
              <given-names>IY</given-names>
            </name>
            <name>
              <surname>Mahmoud</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Barakat</surname>
              <given-names>AF</given-names>
            </name>
            <name>
              <surname>Mentias</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Mohamed</surname>
              <given-names>AH</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Temporal Trends and Outcomes of Mechanical Complications in Patients with Acute Myocardial Infarction</article-title>
          <source>JACC Cardiovasc Interv</source>
          <year>2019</year>
          <volume>12</volume>
          <issue>18</issue>
          <fpage>1825</fpage>
          <lpage>1836</lpage>
          <pub-id pub-id-type="doi">10.1016/j.jcin.2019.04.039</pub-id>
        </element-citation>
        <mixed-citation>10 Elbadawi A, Elgendy IY, Mahmoud K, Barakat AF, Mentias A, Mohamed AH, et al. Temporal Trends and Outcomes of Mechanical Complications in Patients with Acute Myocardial Infarction. JACC Cardiovasc Interv. 2019;12(18):1825-36. doi: 10.1016/j.jcin.2019.04.039.</mixed-citation>
      </ref>
      <ref id="B11">
        <label>11</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Levine</surname>
              <given-names>GN</given-names>
            </name>
            <name>
              <surname>Bates</surname>
              <given-names>ER</given-names>
            </name>
            <name>
              <surname>Blankenship</surname>
              <given-names>JC</given-names>
            </name>
            <name>
              <surname>Bailey</surname>
              <given-names>SR</given-names>
            </name>
            <name>
              <surname>Bittl</surname>
              <given-names>JA</given-names>
            </name>
            <name>
              <surname>Cercek</surname>
              <given-names>B</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention: A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions</article-title>
          <source>Circulation</source>
          <year>2011</year>
          <volume>124</volume>
          <issue>23</issue>
          <fpage>e574</fpage>
          <lpage>e651</lpage>
          <pub-id pub-id-type="doi">10.1161/CIR.0b013e31823ba622</pub-id>
        </element-citation>
        <mixed-citation>11 Levine GN, Bates ER, Blankenship JC, Bailey SR, Bittl JA, Cercek B, et al. 2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention: A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions. Circulation. 2011;124(23):e574-651. doi: 10.1161/CIR.0b013e31823ba622.</mixed-citation>
      </ref>
      <ref id="B12">
        <label>12</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>den Uil</surname>
              <given-names>CA</given-names>
            </name>
            <name>
              <surname>Daemen</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Lenzen</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Maugenest</surname>
              <given-names>AM</given-names>
            </name>
            <name>
              <surname>Joziasse</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>van Geuns</surname>
              <given-names>RJ</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Pulsatile iVAC 2L Circulatory Support in High-Risk Percutaneous Coronary Intervention</article-title>
          <source>EuroIntervention</source>
          <year>2017</year>
          <volume>12</volume>
          <issue>14</issue>
          <fpage>1689</fpage>
          <lpage>1696</lpage>
          <pub-id pub-id-type="doi">10.4244/EIJ-D-16-00371</pub-id>
        </element-citation>
        <mixed-citation>12 den Uil CA, Daemen J, Lenzen MJ, Maugenest AM, Joziasse L, van Geuns RJ, et al. Pulsatile iVAC 2L Circulatory Support in High-Risk Percutaneous Coronary Intervention. EuroIntervention. 2017;12(14):1689-96. doi: 10.4244/EIJ-D-16-00371.</mixed-citation>
      </ref>
      <ref id="B13">
        <label>13</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Van Mieghem</surname>
              <given-names>NM</given-names>
            </name>
            <name>
              <surname>Daemen</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Lenzen</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Zandstra</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Malkin</surname>
              <given-names>O</given-names>
            </name>
            <name>
              <surname>van Geuns</surname>
              <given-names>RJ</given-names>
            </name>
          </person-group>
          <article-title>The PulseCath iVAC 2L Left Ventricular Assist Device: Conversion to a Percutaneous Transfemoral Approach</article-title>
          <source>EuroIntervention</source>
          <year>2015</year>
          <volume>11</volume>
          <issue>7</issue>
          <fpage>835</fpage>
          <lpage>839</lpage>
          <pub-id pub-id-type="doi">10.4244/EIJV11I7A168</pub-id>
        </element-citation>
        <mixed-citation>13 Van Mieghem NM, Daemen J, Lenzen MJ, Zandstra R, Malkin O, van Geuns RJ. The PulseCath iVAC 2L Left Ventricular Assist Device: Conversion to a Percutaneous Transfemoral Approach. EuroIntervention. 2015;11(7):835-9. doi: 10.4244/EIJV11I7A168.</mixed-citation>
      </ref>
      <ref id="B14">
        <label>14</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Jones</surname>
              <given-names>HA</given-names>
            </name>
            <name>
              <surname>Kalisetti</surname>
              <given-names>DR</given-names>
            </name>
            <name>
              <surname>Gaba</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>McCormick</surname>
              <given-names>DJ</given-names>
            </name>
            <name>
              <surname>Goldberg</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
          <article-title>Left Ventricular Assist for High-Risk Percutaneous Coronary Intervention</article-title>
          <source>J Invasive Cardiol</source>
          <year>2012</year>
          <volume>24</volume>
          <issue>10</issue>
          <fpage>544</fpage>
          <lpage>550</lpage>
        </element-citation>
        <mixed-citation>14 Jones HA, Kalisetti DR, Gaba M, McCormick DJ, Goldberg S. Left Ventricular Assist for High-Risk Percutaneous Coronary Intervention. J Invasive Cardiol. 2012;24(10):544-50.</mixed-citation>
      </ref>
      <ref id="B15">
        <label>15</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Patterson</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Perera</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Redwood</surname>
              <given-names>SR</given-names>
            </name>
          </person-group>
          <article-title>Intra-Aortic Balloon Pump for High-Risk Percutaneous Coronary Intervention</article-title>
          <source>Circ Cardiovasc Interv</source>
          <year>2014</year>
          <volume>7</volume>
          <issue>5</issue>
          <fpage>712</fpage>
          <lpage>720</lpage>
          <pub-id pub-id-type="doi">10.1161/CIRCINTERVENTIONS.114.001258</pub-id>
        </element-citation>
        <mixed-citation>15 Patterson T, Perera D, Redwood SR. Intra-Aortic Balloon Pump for High-Risk Percutaneous Coronary Intervention. Circ Cardiovasc Interv. 2014;7(5):712-20. doi: 10.1161/CIRCINTERVENTIONS.114.001258.</mixed-citation>
      </ref>
      <ref id="B16">
        <label>16</label>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Bulum</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Bastos</surname>
              <given-names>MB</given-names>
            </name>
            <name>
              <surname>Hlinomaz</surname>
              <given-names>O</given-names>
            </name>
            <name>
              <surname>Malkin</surname>
              <given-names>O</given-names>
            </name>
            <name>
              <surname>Pawlowski</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Dragula</surname>
              <given-names>M</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Pulsatile Left Ventricular Assistance in High-Risk Percutaneous Coronary Interventions: Short-Term Outcomes</article-title>
          <source>J Clin Med</source>
          <year>2024</year>
          <volume>13</volume>
          <issue>18</issue>
          <fpage>5357</fpage>
          <lpage>5357</lpage>
          <pub-id pub-id-type="doi">10.3390/jcm13185357</pub-id>
        </element-citation>
        <mixed-citation>16 Bulum J, Bastos MB, Hlinomaz O, Malkin O, Pawlowski T, Dragula M, et al. Pulsatile Left Ventricular Assistance in High-Risk Percutaneous Coronary Interventions: Short-Term Outcomes. J Clin Med. 2024;13(18):5357. doi: 10.3390/jcm13185357.</mixed-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="S1" xml:lang="en">
    <front-stub>
      <article-id pub-id-type="doi">10.36660/abc.202250236i</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Case Report</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Brazil's First High-Risk Percutaneous Coronary Intervention with Hemodynamic Support from a Percutaneous Pulsatile Device: A Case Report</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0003-0633-3853</contrib-id>
          <name>
            <surname>Nicolau</surname>
            <given-names>Andr&#233; M.</given-names>
          </name>
          <role>Conception and design of the research and Writing of the manuscript</role>
          <role>Acquisition of data</role>
          <role>Critical revision of the manuscript for content</role>
          <xref ref-type="aff" rid="aff3">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Melo</surname>
            <given-names>Pedro H. M. C. de</given-names>
          </name>
          <role>Conception and design of the research and Writing of the manuscript</role>
          <role>Acquisition of data</role>
          <role>Critical revision of the manuscript for content</role>
          <xref ref-type="aff" rid="aff3">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Oliveira</surname>
            <given-names>Lucas Aguiar Alencar de</given-names>
          </name>
          <role>Conception and design of the research and Writing of the manuscript</role>
          <role>Critical revision of the manuscript for content</role>
          <xref ref-type="aff" rid="aff3">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Bergo</surname>
            <given-names>Rafael</given-names>
          </name>
          <role>Critical revision of the manuscript for content</role>
          <xref ref-type="aff" rid="aff3">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Kleinsorge</surname>
            <given-names>Thiago A.</given-names>
          </name>
          <role>Critical revision of the manuscript for content</role>
          <xref ref-type="aff" rid="aff3">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Godinho</surname>
            <given-names>Roger Renault</given-names>
          </name>
          <role>Critical revision of the manuscript for content</role>
          <xref ref-type="aff" rid="aff3">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-6260-9626</contrib-id>
          <name>
            <surname>Brito</surname>
            <given-names>F&#225;bio S&#226;ndoli de</given-names>
            <suffix>Jr</suffix>
          </name>
          <role>Critical revision of the manuscript for content</role>
          <xref ref-type="aff" rid="aff3">
            <sup>1</sup>
          </xref>
          <xref ref-type="aff" rid="aff4">
            <sup>2</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Abizaid</surname>
            <given-names>Alexandre A.</given-names>
          </name>
          <role>Critical revision of the manuscript for content</role>
          <xref ref-type="aff" rid="aff3">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Campos</surname>
            <given-names>Carlos de Magalh&#227;es</given-names>
          </name>
          <role>Conception and design of the research and Writing of the manuscript</role>
          <role>Acquisition of data</role>
          <role>Critical revision of the manuscript for content</role>
          <xref ref-type="aff" rid="aff3">
            <sup>1</sup>
          </xref>
          <xref ref-type="corresp" rid="c2"/>
        </contrib>
        <aff id="aff3">
          <label>1</label>
          <addr-line>
            <named-content content-type="city">S&#227;o Paulo</named-content>
            <named-content content-type="state">SP</named-content>
          </addr-line>
          <country country="BR">Brazil</country>
          <institution content-type="original">Instituto do Cora&#231;&#227;o do Hospital das Cl&#237;nicas da Faculdade de Medicina da Universidade de S&#227;o Paulo, S&#227;o Paulo, SP &#8211; Brazil</institution>
        </aff>
        <aff id="aff4">
          <label>2</label>
          <addr-line>
            <named-content content-type="city">S&#227;o Paulo</named-content>
            <named-content content-type="state">SP</named-content>
          </addr-line>
          <country country="BR">Brazil</country>
          <institution content-type="original">Hospital S&#237;rio-Liban&#234;s, S&#227;o Paulo, SP &#8211; Brazil</institution>
        </aff>
      </contrib-group>
      <author-notes>
        <corresp id="c2"><label>Mailing Address:</label><bold>Carlos de Magalh&#227;es Campos</bold> &#8226; Instituto do Cora&#231;&#227;o do Hospital das Cl&#237;nicas da Faculdade de Medicina da Universidade de S&#227;o Paulo &#8211; Avenida Dr. Eneas de Carvalho Aguiar, 44. Postal Code <postal-code>01246-903</postal-code>, S&#227;o Paulo, SP &#8211; Brazil E-mail: <email>carlosacampos1@gmail.com</email> </corresp>
        <fn fn-type="coi-statement">
          <label>Potential conflict of interest</label>
          <p>No potential conflict of interest relevant to this article was reported.</p>
        </fn>
        <fn fn-type="edited-by">
          <label>Editor responsible for the review:</label>
          <p>Henrique Ribeiro</p>
        </fn>
      </author-notes>
      <abstract>
        <title>Abstract</title>
        <p>Percutaneous coronary intervention (PCI) is the most widely used coronary revascularization method worldwide, even in cases of high anatomical complexity. However, this increasing complexity has increased the risks associated with the procedure. Mechanical circulatory assist devices (MCADs), such as the iVAC 2L, have been used for hemodynamic support in high-risk PCIs.</p>
        <p>We describe the first case in Brazil of PCI performed with the support of the iVAC 2L, a pulsatile MCAD. The patient, an 81-year-old man, had functional class III angina and severe lesions in the left main coronary artery (LMCA), left anterior descending artery (LAD), and circumflex artery (CX), associated with extensive calcification. The procedure was performed with the support of the iVAC 2L, and PCI was performed with stenting of the LMCA, LAD, and CX. The entire procedure was performed without the need for vasoactive drugs, and the device was removed without vascular complications.</p>
        <p>High-risk PCI has become increasingly common, often requiring ventricular mechanical support. The iVAC 2L offers advantages such as pulsatile flow and ease of implantation, making it an alternative to the intra-aortic balloon pump and Impella. This report highlights the potential use of the iVAC 2L in Brazil, expanding therapeutic options for high-risk patients.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <title>Keywords</title>
        <kwd>Percutaneous Coronary Intervention</kwd>
        <kwd>Heart-Assist Devices</kwd>
        <kwd>Coronary Artery Disease</kwd>
      </kwd-group>
      <funding-group>
        <funding-statement><bold>Sources of funding</bold> There were no external funding sources for this study.</funding-statement>
      </funding-group>
    </front-stub>
    <body>
      <sec sec-type="intro">
        <title>Introduction</title>
        <p>Percutaneous coronary intervention (PCI) is the most commonly performed revascularization method, even in cases of high anatomical complexity, particularly in patients at high surgical risk.<sup><xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B2">2</xref></sup> However, with the increase in anatomical complexity, associated with population aging and the increased incidence of comorbidities, an increase in the risk profile of PCIs is observed.<sup><xref ref-type="bibr" rid="B3">3</xref>&#8211;<xref ref-type="bibr" rid="B5">5</xref></sup></p>
        <p>In this context, mechanical circulatory assistance devices (MCAD) are known to promote improvements in hemodynamic parameters<sup><xref ref-type="bibr" rid="B6">6</xref>.<xref ref-type="bibr" rid="B7">7</xref></sup> and are recommended for temporary mechanical circulatory support in the high-risk PCI context.<sup><xref ref-type="bibr" rid="B8">8</xref>&#8211;<xref ref-type="bibr" rid="B11">11</xref></sup></p>
        <p>The iVAC 2L device (Pulsecath BV, Amsterdam, The Netherlands) is a retrograde insertion MCAD via the femoral artery. The device consists of a bidirectional valve connected to an extracorporeal membrane by a 17Fr cannula. Blood is aspirated from the ventricle through the catheter tip during systole to the membrane, and during diastole, the membrane ejects blood into the ascending aorta through the bidirectional valve (<xref ref-type="fig" rid="f8">Figure 1</xref>). The membrane is moved by mobilizing helium gas through the intra-aortic balloon console (<xref ref-type="fig" rid="f13">Video 1</xref>), which controls the device's operation. The catheter tip is positioned retrogradely below the aortic valve and into the left ventricle (<xref ref-type="fig" rid="f8">Figure 1</xref>). Under ideal conditions (heart rate 70-80 bpm), the additional cardiac output is up to 2.0 L/min, with pulsatile flow. The safety and function of the iVAC 2L have been previously reported.<sup><xref ref-type="bibr" rid="B12">12</xref>,<xref ref-type="bibr" rid="B13">13</xref></sup></p>
        <fig id="f8">
          <label>Figure 1</label>
          <caption>
            <title>1A) Positioning of the iVAC 2.0 device with the tip of the left ventricle (solid arrow) and the directional valve in the ascending aorta (dotted arrow).</title>
            <p>A 0.035-inch guide wire helps recognize the position of the aortic sinus (marked with a triangle). 1B) iVAC 2.0 device</p>
          </caption>
          <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf01-en.tif"/></fig>
        <fig id="f13">
          <label>Video 1</label>
          <caption>
            <title>See: <ext-link ext-link-type="uri" xlink:href="http://abccardiol.org/supplementary-material/2025/12210/2025-0236_RC_Video_1.mp4">http://abccardiol.org/supplementary-material/2025/12210/2025-0236_RC_Video_1.mp4</ext-link> </title>
          </caption>
          <media id="mf13" mime-subtype="mp4" mimetype="video" xlink:href="https://minio.scielo.br/documentstore/1678-4170/WP53jZhvJQxYFYBgKbRZBNS/5a14afb00d6fc9811ba29b68d51b940df7153ee2.mp4"> </media>
          <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf02-en.tif"/></fig>
        <p>We will present the first case in Brazil of complex high-risk PCI performed with the support of the iVAC 2L device.</p>
      </sec>
      <sec sec-type="cases">
        <title>Clinical Case</title>
        <p>We report the case of an 81-year-old man with hypertension and diabetes, referred to our service with dyspnea and class III angina. A functional evaluation with scintigraphy was performed, which demonstrated ischemia in the anterior and anteroseptal walls, in addition to a drop in blood pressure at peak exercise and a left ventricular ejection fraction of 34%. Cardiac catheterization was then indicated, which revealed lesions in the left main coronary artery (80%), left anterior descending artery (70% and 80% lesions in the proximal and middle thirds), and circumflex artery (70% in the proximal third), associated with extensive coronary calcification (<xref ref-type="fig" rid="f9">Figure 2</xref>) and a Syntax Score of 32. The Heart Team discussed the case, and percutaneous treatment was chosen after considering high surgical risk (Euroscore II 7.74%, STS 5.82%), and clinical frailty assessed by a multidisciplinary team.</p>
        <fig id="f9">
          <label>Figure 2</label>
          <caption>
            <title>Cardiac catheterization demonstrating lesions of 80% in the left main coronary artery (LMCA), 80% in the LAD, and 70% in the Cx.</title>
          </caption>
          <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf03-en.tif"/></fig>
        <p>The procedure began with femoral puncture, followed by bilateral arteriography (<xref ref-type="fig" rid="f10">Figure 3</xref>) to determine the best strategy. Both common femoral arteries had adequate calibers to accommodate the iVAC 2L device introducer. A significant atherosclerotic lesion was observed in the distal third of the right common femoral artery, and it was decided to position the iVAC 2L device through the left common femoral artery.</p>
        <fig id="f10">
          <label>Figure 3</label>
          <caption>
            <title>Left femoral and inguinal arteriography.</title>
            <p>3A) Left femoral arteriography demonstrating good caliber of the artery. 3B) Left iliac arteriography demonstrating good caliber of the artery and significant tortuosity in the common iliac artery.</p>
          </caption>
          <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf04-en.tif"/></fig>
        <p>The left femoral artery was pre-closed with two Perclose Proglide devices, followed by insertion of an 18F hydrophilic introducer via a 0.035-inch high-support guidewire ("Amplatz Super Stiff"). Through the right femoral artery, a 0.035-inch guidewire was positioned in the non-coronary sinus to mark the level of the aortic valve. Subsequently, the iVAC 2L device was advanced, positioning its tip in the LV, 2 cm below the aortic valve, maintaining the bidirectional valve in the ascending aorta (<xref ref-type="fig" rid="f8">Figure 1</xref>). The device was connected to the IABP console (intra-aortic balloon pump), configured for ECG triggering, with maximum inflation and 1:1 triggering, providing an estimated additional flow of approximately 2.0 L, given the patient's heart rate of approximately 70-80 bpm (<xref ref-type="fig" rid="f14">Video 2</xref>).</p>
        <fig id="f14">
          <label>Video 2</label>
          <caption>
            <title>See: <ext-link ext-link-type="uri" xlink:href="http://abccardiol.org/supplementary-material/2025/12210/2025-0236_RC_Video_2.mp4">http://abccardiol.org/supplementary-material/2025/12210/2025-0236_RC_Video_2.mp4</ext-link> </title>
          </caption>
          <media id="mf14" mime-subtype="mp4" mimetype="video" xlink:href="https://minio.scielo.br/documentstore/1678-4170/WP53jZhvJQxYFYBgKbRZBNS/acd37adddddbe8533e7dedc50dc425009ebcc8e8.mp4"> </media>
          <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf05-en.tif"/></fig>
        <p>We used a 3.5 7Fr EBU catheter for left coronary catheterization. Due to the presence of a severely stenotic lesion, pre-dilation was performed to allow evaluation with intravascular ultrasound (IVUS), which demonstrated a minimum luminal area of 1.88 mm<sup>2</sup>, fibrolipid plaque, and significant calcification, in addition to ulceration in the LMCA and myocardial bridge in the distal segment of the artery (<xref ref-type="fig" rid="f11">Figure 4</xref>). Lesion preparation was performed with dedicated balloons (Cutting Balloon and non-compliant balloon), with adequate results confirmed by IVUS. Subsequently, we implanted drug-eluting stents in the mid-LAD, ostial CX with minimal protrusion into the main, and proximal LAD with extension into the main, using the "Mini-Crush" technique. Post-dilation of the stents was performed, and carina adjustment was performed with the "Kissing-balloon" technique. Control IVUS was performed with adequate expansion and apposition of the struts, without complications (<xref ref-type="fig" rid="f12">Figure 5</xref>). The entire procedure was performed under conscious sedation, without the use of vasoactive drugs. After the procedure, the device was removed, and hemostasis was performed with perclose, as mentioned. Final arteriography showed no vascular complications (<xref ref-type="fig" rid="f12">Figure 5</xref>).<sup><xref ref-type="bibr" rid="B8">8</xref></sup></p>
        <fig id="f11">
          <label>Figure 4</label>
          <caption>
            <title>Intravascular ultrasound (IVUS) evaluation prior to stent implantation with guidewire positioned in the distal segment of the left anterior descending artery.</title>
            <p>4A) Longitudinal section (Long view) from the left anterior descending coronary artery to the left main coronary artery. 4B) Presence of an ulcer in the LMCA, marked with a "#", demonstrating communication between the lesion and the lumen. 4C) Extensive calcification in the left anterior descending artery, with a calcification angle &gt;270&#176; recognized by the posterior acoustic shadow, absent only between 1 and 4 o'clock. 4D) Minimum luminal area in the left anterior descending artery, measuring 1.88 mm<sup>2</sup>. 4E) Presence of a myocardial bridge in the distal portion of the evaluated segment (marked with a "*"), serving as a distal reference for stent positioning. Half-moon sign.</p>
          </caption>
          <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf06-en.tif"/></fig>
        <fig id="f12">
          <label>Figure 5</label>
          <caption>
            <title>Final angiographic and ultrasound results.</title>
            <p>5A) Final result with Mini-Crush technique, LCA-DA, and Cx. 5B) Final IVUS evaluation with minimum in-stent luminal area of 6.69 mm2. 5C) Final left femoral arteriography without complications.</p>
          </caption>
          <graphic xlink:href="1678-4170-abc-122-10-e20250236-50236-gf07-en.tif"/></fig>
      </sec>
      <sec sec-type="discussion">
        <title>Discussion</title>
        <p>High-risk PCIs are becoming increasingly frequent and with better results.<sup><xref ref-type="bibr" rid="B3">3</xref>&#8211;<xref ref-type="bibr" rid="B5">5</xref></sup> In this context, several MCADs were developed.<sup><xref ref-type="bibr" rid="B14">14</xref></sup> Historically, IABP has been used in clinical practice for mechanical support in high-risk PCIs. Evidence from randomized clinical trials in this context has failed to demonstrate benefit in reducing major in-hospital cardiovascular events, although long-term analyses indicate a possible, albeit speculative, long-term benefit.<sup><xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B15">15</xref></sup> Thus, although IABP offers mechanical support and improves coronary and cerebral perfusion, the modest gain in cardiac output and the lack of evidence of cardiovascular benefits led to its non-recommended use in guidelines and consensus.<sup><xref ref-type="bibr" rid="B2">2</xref>,<xref ref-type="bibr" rid="B8">8</xref></sup></p>
        <p>The operation and safety of the iVAC 2L device have been demonstrated in previous studies<sup><xref ref-type="bibr" rid="B12">12</xref>,<xref ref-type="bibr" rid="B13">13</xref>,<xref ref-type="bibr" rid="B16">16</xref></sup> providing a cardiac output of up to 2.0 L/min, approximately 3-4x the output provided by the IABP (<xref ref-type="table" rid="t2">Table 1</xref>). When compared to continuous flow devices such as Impella and ECMO, its advantages include a possibly more physiological pulsatile flow, ease of implantation, and the use of a balloon console already available in many centers, eliminating the need for a dedicated console. Compared to VA ECMO, iVAC has the advantage, as do Impella and IABP, of decompressing the left ventricle and decreasing systemic vascular resistance. The disadvantages include the 18F profile (compared to the 14F of the Impella CP) and the lower support (up to 2L compared to the 4.3L of the Impella or up to 10L/min of the VA ECMO) (<xref ref-type="table" rid="t2">Table 1</xref>).</p>
        <table-wrap id="t2">
          <label>Table 1</label>
          <caption>
            <title>Comparison between iVAC 2L, IABP, Impella, and VA ECMO devices</title>
          </caption>
          <table frame="hsides" rules="groups">
            <colgroup width="20%">
              <col/>
              <col/>
              <col/>
              <col/>
              <col/>
            </colgroup>
            <thead style="border-top: thin solid; border-bottom: thin solid; border-color: #000000">
              <tr style="background-color:#76B4CF">
                <th align="left" valign="middle"/>
                <th align="center" valign="middle">iVAC 2L</th>
                <th align="center" valign="middle">BIA</th>
                <th align="center" valign="middle">Impella</th>
                <th align="center" valign="middle">VA ECMO</th>
              </tr>
            </thead>
            <tbody style="border-bottom: thin solid; border-color: #000000">
              <tr>
                <td align="left" valign="middle">Additional debit</td>
                <td align="center" valign="middle">2.0L/min</td>
                <td align="center" valign="middle">0.3-0.5L/min</td>
                <td align="center" valign="middle">2.5-5.5L/min</td>
                <td align="center" valign="middle">Up to 7L/min</td>
              </tr>
              <tr style="background-color:#C7DFEC">
                <td align="left" valign="middle">Access</td>
                <td align="center" valign="middle">Femoral 18Fr</td>
                <td align="center" valign="middle">Femoral 7-8Fr</td>
                <td align="center" valign="middle">13-14Fr</td>
                <td align="center" valign="middle">14-19Fr Arterial<break/> 17-21Fr ECMO</td>
              </tr>
              <tr>
                <td align="left" valign="middle">Mechanism</td>
                <td align="center" valign="middle">Extracorporeal membrane</td>
                <td align="center" valign="middle">Counterpulsation</td>
                <td align="center" valign="middle">Microaxial pump</td>
                <td align="center" valign="middle">Centrifugal pump</td>
              </tr>
              <tr style="background-color:#C7DFEC">
                <td align="left" valign="middle">Synchronization with heart rate</td>
                <td align="center" valign="middle">Yes</td>
                <td align="center" valign="middle">Yes</td>
                <td align="center" valign="middle">No</td>
                <td align="center" valign="middle">No</td>
              </tr>
              <tr>
                <td align="left" valign="middle">Afterload</td>
                <td align="center" valign="middle">Decreases</td>
                <td align="center" valign="middle">Decreases</td>
                <td align="center" valign="middle">Decreases</td>
                <td align="center" valign="middle">Increases</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
      <sec sec-type="data-availability" specific-use="data-in-article">
        <title>Data Availability</title>
        <p>The underlying content of the research text is contained within the manuscript.</p>
      </sec>
    </body>
    <back>
      <fn-group>
        <fn fn-type="financial-disclosure" id="fn5">
          <label>Sources of funding</label>
          <p>There were no external funding sources for this study.</p>
        </fn>
        <fn fn-type="other" id="fn6">
          <label>Study association</label>
          <p>This study is not associated with any thesis or dissertation work.</p>
        </fn>
        <fn fn-type="other" id="fn7">
          <label>Ethics approval and consent to participate</label>
          <p>Written informed consent was obtained from the patient for the procedure and for the publication of the case details and accompanying images.</p>
        </fn>
        <fn fn-type="other" id="fn8">
          <label>Use of Artificial Intelligence</label>
          <p>The authors did not use any artificial intelligence tools in the development of this work.</p>
        </fn>
      </fn-group>
    </back>
  </sub-article>
</article>
