<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.1" specific-use="sps-1.9" article-type="research-article" xml:lang="pt">
  <front>
    <journal-meta>
      <journal-id journal-id-type="nlm-ta">Arq Bras Cardiol</journal-id>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id specific-use="scielo-v3" pub-id-type="publisher-id">5pcQZDTNDVWgD4DTzPj73sx</article-id>
      <article-id specific-use="scielo-v2" pub-id-type="publisher-id">S0066-782X2021000900028</article-id>
      <article-id pub-id-type="publisher-id">abc.20200135</article-id>
      <article-id pub-id-type="doi">10.36660/abc.20200135</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigo Original</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Evolu&#231;&#227;o Tardia das Pr&#243;teses Biol&#243;gicas e Mec&#226;nicas em Posi&#231;&#227;o A&#243;rtica</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-3799-9466</contrib-id>
          <name>
            <surname>Bruscky</surname>
            <given-names>Larissa Ventura Ribeiro</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Gun</surname>
            <given-names>Carlos</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0001-7180-5779</contrib-id>
          <name>
            <surname>Ramos</surname>
            <given-names>Auristela Isabel de Oliveira</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0003-1996-4144</contrib-id>
          <name>
            <surname>Morais</surname>
            <given-names>Alice Lemos</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
      </contrib-group>
      <aff id="aff1">
        <label>1</label>
        <institution content-type="orgname">Instituto Dante Pazzanese de Cardiologia</institution>
        <addr-line>
          <named-content content-type="city">S&#227;o Paulo</named-content>
          <named-content content-type="state">SP</named-content>
        </addr-line>
        <country country="BR">Brasil</country>
        <institution content-type="original">Instituto Dante Pazzanese de Cardiologia, S&#227;o Paulo, SP &#8211; Brasil</institution>
      </aff>
      <author-notes>
        <corresp id="c01"> Correspond&#234;ncia: Larissa Ventura Ribeiro Bruscky &#8226; Instituto Dante Pazzanese de Cardiologia &#8211; Av. Dr. Dante Pazzanese, 500. CEP 04012-909, Vila Mariana, S&#227;o Paulo, SP &#8211; Brasil E-mail: <email>larissaventurar@gmail.com</email> </corresp>
        <fn fn-type="con">
          <p>Contribui&#231;&#227;o dos autores</p>
          <p>Concep&#231;&#227;o e desenho da pesquisa, Reda&#231;&#227;o do manuscrito e Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do intelectual importante: Bruscky LVR, Gun C, Ramos AIO; Obten&#231;&#227;o de dados: Bruscky LVR; An&#225;lise e interpreta&#231;&#227;o dos dados: Bruscky LVR, Gun C, Ramos AIO, Morais AL; An&#225;lise estat&#237;stica: Morais AL.</p>
        </fn>
        <fn fn-type="conflict">
          <p>Potencial conflito de interesse</p>
          <p>N&#227;o h&#225; conflito com o presente artigo</p>
        </fn>
      </author-notes>
      <pub-date date-type="pub" publication-format="electronic">
        <day>26</day>
        <month>07</month>
        <year>2021</year>
      </pub-date>
      <pub-date publication-format="electronic" date-type="collection">
        <month>07</month>
        <year>2021</year>
      </pub-date>
      <volume>117</volume>
      <issue>1</issue>
      <fpage>28</fpage>
      <lpage>36</lpage>
      <history>
        <date date-type="received">
          <day>02</day>
          <month>03</month>
          <year>2020</year>
        </date>
        <date date-type="rev-recd">
          <day>02</day>
          <month>06</month>
          <year>2020</year>
        </date>
        <date date-type="accepted">
          <day>05</day>
          <month>08</month>
          <year>2020</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/" xml:lang="en">
          <license-p> This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. </license-p>
        </license>
      </permissions>
      <abstract>
        <title>Resumo</title>
        <sec>
          <title>Fundamento</title>
          <p> Apesar da constante renova&#231;&#227;o e do aprimoramento das pr&#243;teses valvares card&#237;acas, a decis&#227;o sobre substitui&#231;&#227;o por pr&#243;tese biol&#243;gica ou mec&#226;nica permanece controversa.</p>
        </sec>
        <sec>
          <title>Objetivo</title>
          <p> Comparar pacientes submetidos &#224; cirurgia para troca valvar a&#243;rtica utilizando substituto biol&#243;gico ou mec&#226;nico.</p>
        </sec>
        <sec>
          <title>M&#233;todos</title>
          <p> Estudo observacional, do tipo coorte hist&#243;rica por an&#225;lise de prontu&#225;rio. Foram selecionados 202 operados entre 2004 e 2008, com seguimento m&#233;dio de 10 anos. O n&#237;vel de signific&#226;ncia estat&#237;stica adotado foi de 5%.</p>
        </sec>
        <sec>
          <title>Resultados</title>
          <p> A m&#233;dia de idade foi de aproximadamente 50 anos para ambos os grupos, com a maioria (70%) do sexo masculino. A probabilidade de sobrevida livre de &#243;bito e reopera&#231;&#227;o foi significativamente maior nos pacientes com pr&#243;tese mec&#226;nica (HR=0,33; IC 95%=0,13-0,79; p=0,013). N&#227;o houve diferen&#231;a entre os grupos em rela&#231;&#227;o &#224; mortalidade tardia. Por outro lado, o risco de reopera&#231;&#227;o foi significativamente maior em pacientes tratados com pr&#243;tese biol&#243;gica em compara&#231;&#227;o com a pr&#243;tese mec&#226;nica (HR=0,062; IC 95%=0,008-0,457; p=0,006). O risco de eventos adversos composto de acidente vascular encef&#225;lico (AVE), sangramento, endocardite, trombose e regurgita&#231;&#227;o paraprot&#233;tica foi semelhante entre os grupos (HR=1,20; IC 95%=0,74-1,93; p=0,44). O risco de sangramento foi significativamente maior em pacientes tratados com pr&#243;tese mec&#226;nica (HR=3,65; IC 95%=1,43-9,29; p=0,0064), por&#233;m n&#227;o houve sangramento fatal.</p>
        </sec>
        <sec>
          <title>Conclus&#227;o</title>
          <p> N&#227;o h&#225; diferen&#231;a de mortalidade em 10 anos entre os dois grupos. H&#225; aumento significativo no risco de reopera&#231;&#227;o ao se optar por pr&#243;teses biol&#243;gicas, principalmente para os menores de 30 anos de idade. J&#225; os pacientes portadores de pr&#243;tese mec&#226;nica t&#234;m maior risco de sangramento n&#227;o fatal.</p>
        </sec>
      </abstract>
      <kwd-group xml:lang="pt">
        <kwd>Valva A&#243;rtica</kwd>
        <kwd>Biopr&#243;tese/tend&#234;ncias</kwd>
        <kwd>Implante de Pr&#243;tese de Valva Card&#237;aca/complica&#231;&#245;es</kwd>
        <kwd>Pr&#243;teses Valvulares Card&#237;acas</kwd>
        <kwd>Febre Reum&#225;tica</kwd>
      </kwd-group>
      <counts>
        <fig-count count="10"/>
        <table-count count="2"/>
        <equation-count count="0"/>
        <ref-count count="13"/>
        <page-count count="9"/>
      </counts>
    </article-meta>
  </front>
  <body>
    <sec sec-type="intro">
      <title>Introdu&#231;&#227;o</title>
      <p>A substitui&#231;&#227;o da valva a&#243;rtica &#233; realizada desde a d&#233;cada de 1950.<sup><xref rid="B1" ref-type="bibr">1</xref></sup> Desde ent&#227;o, o avan&#231;o t&#233;cnico no projeto da pr&#243;tese e a otimiza&#231;&#227;o do procedimento cir&#250;rgico reduziram o risco de complica&#231;&#245;es relacionadas ao procedimento, al&#233;m de melhorar significativamente o progn&#243;stico a longo prazo.<sup><xref rid="B1" ref-type="bibr">1</xref></sup></p>
      <p>Apesar da constante renova&#231;&#227;o e aprimoramento das pr&#243;teses, a decis&#227;o sobre substitui&#231;&#227;o por pr&#243;tese biol&#243;gica ou mec&#226;nica para a posi&#231;&#227;o a&#243;rtica permanece controversa. A principal desvantagem da pr&#243;tese biol&#243;gica &#233; a degenera&#231;&#227;o progressiva dos folhetos, por&#233;m apresenta uma baixa trombogenicidade com menor tempo de anticoagula&#231;&#227;o e aus&#234;ncia de ru&#237;dos. J&#225; as pr&#243;teses mec&#226;nicas exigem anticoagula&#231;&#227;o prolongada, modifica&#231;&#245;es substanciais no estilo de vida e carregam um maior risco a longo prazo de tromboembolismo e eventos hemorr&#225;gicos.<sup><xref rid="B2" ref-type="bibr">2</xref></sup></p>
      <p>Existem poucos estudos brasileiros comparativos entre pr&#243;teses biol&#243;gicas e mec&#226;nicas, bem como poucos s&#227;o os que descrevem a influ&#234;ncia do contexto epidemiol&#243;gico no desfecho em um per&#237;odo de 10 anos.</p>
      <p>No Brasil, a causa mais comum de valvopatia &#233; a febre reum&#225;tica, logo, os pacientes s&#227;o submetidos &#224; interven&#231;&#227;o cir&#250;rgica em uma faixa et&#225;ria mais baixa que a popula&#231;&#227;o operada em pa&#237;ses desenvolvidos.<sup><xref rid="B3" ref-type="bibr">3</xref></sup> Al&#233;m da idade, muitos dos pacientes com valvopatia s&#227;o origin&#225;rios de regi&#245;es pouco favorecidas, portanto t&#234;m dificuldade em fazer o controle da anticoagula&#231;&#227;o.</p>
      <p>Dentro desse contexto, o objetivo desse estudo foi avaliar mortalidade, reopera&#231;&#227;o e eventos adversos em pacientes submetidos &#224; cirurgia para troca valvar a&#243;rtica por substituto biol&#243;gico ou mec&#226;nico, em um hospital terci&#225;rio da rede p&#250;blica do Estado de S&#227;o Paulo.</p>
    </sec>
    <sec sec-type="methods">
      <title>M&#233;todos</title>
      <p>O delineamento do estudo foi observacional, do tipo coorte hist&#243;rica por an&#225;lise de prontu&#225;rio.</p>
      <sec>
        <title>Amostra</title>
        <p>Pacientes com idade maior que 18 anos e menor ou igual a 65 anos, submetidos a troca valvar a&#243;rtica por pr&#243;tese biol&#243;gica ou mec&#226;nica, no per&#237;odo de 01 de janeiro de 2004 a 31 de dezembro de 2008, com seguimento m&#233;dio de 10 anos. Todas as pr&#243;teses mec&#226;nicas utilizadas foram de duplo folheto e todas as biol&#243;gicas implantadas foram pr&#243;teses nacionais disponibilizadas pelo Sistema &#218;nico de Sa&#250;de.</p>
        <p>Desfecho prim&#225;rio combinado: tempo de sobrevida livre de reopera&#231;&#227;o e mortalidade tardia (ap&#243;s 30 dias de cirurgia) por todas as causas. Desfecho secund&#225;rio: tempo de sobrevida livre de evento adverso, composto de AVC, sangramento, endocardite, trombose e RPP.</p>
        <p>Foi avaliado tamb&#233;m idade, sexo, etiologia da disfun&#231;&#227;o da pr&#243;tese a&#243;rtica, al&#233;m do ritmo card&#237;aco, uso de anticoagula&#231;&#227;o e dados ecocardiogr&#225;ficos considerando grau de hipertens&#227;o pulmonar, fra&#231;&#227;o de eje&#231;&#227;o de ventr&#237;culo esquerdo e di&#226;metros ventriculares.</p>
        <p>A escolha da pr&#243;tese foi realizada a crit&#233;rio do m&#233;dico cardiologista que acompanhava o paciente, levando em considera&#231;&#227;o a idade, possibilidade de anticoagula&#231;&#227;o, caracter&#237;sticas cl&#237;nicas e contexto socioecon&#244;mico.</p>
      </sec>
      <sec>
        <title>Aspectos &#233;ticos</title>
        <p>Os aspectos cl&#237;nicos e cir&#250;rgicos durante o per&#237;odo de estudo foram completados a partir de informa&#231;&#245;es escritas nos prontu&#225;rios dos pacientes, n&#227;o existindo risco atribu&#237;do ao indiv&#237;duo. Quanto &#224; privacidade e &#224; confidencialidade, s&#227;o garantidas a preserva&#231;&#227;o do anonimato dos pacientes e a utiliza&#231;&#227;o dos dados obtidos na pesquisa apenas para a finalidade do projeto. O projeto de investiga&#231;&#227;o recebeu aprova&#231;&#227;o pr&#233;via da Comiss&#227;o de &#201;tica em Pesquisa em Sa&#250;de do Instituto Dante Pazzanese de Cardiologia, registrado sob o n&#176; 4864/2018, para obten&#231;&#227;o de permiss&#227;o de execu&#231;&#227;o no &#226;mbito deste hospital.</p>
      </sec>
      <sec>
        <title>Defini&#231;&#245;es</title>
        <p>As defini&#231;&#245;es foram obtidas do artigo de For&#231;a Tarefa da European Association of Percutaneous Cardiovascular Interventions (EAPCI), European Society of Cardiology (ESC) e European Association for Cardio-Thoracic Surgery (EACTS) e tamb&#233;m da Diretriz Brasileira de Valvopatia de 2011 com atualiza&#231;&#227;o de 2017.</p>
      </sec>
      <sec>
        <title>An&#225;lise estat&#237;stica</title>
        <p>As vari&#225;veis quantitativas foram descritas por m&#233;dia e desvio padr&#227;o, e as qualitativas por meio de frequ&#234;ncias absolutas e relativas.</p>
        <p>A compara&#231;&#227;o entre os grupos na fase de balanceamento foi realizada pelo teste t-Student para amostras independentes, em caso de vari&#225;veis quantitativas, e teste exato de Fisher, para as vari&#225;veis qualitativas (taxas e propor&#231;&#245;es).</p>
        <p>A an&#225;lise descritiva foi realizada no Excel 2004 e o teste de normalidade (Shapiro Wilk) pelo SPSS com n&#237;vel de signific&#226;ncia de 5%.</p>
        <p>Para avaliar o tempo de sobrevida, o tempo de sobrevida livre de reopera&#231;&#227;o e tempo de sobrevida livre de eventos adversos (AVC, sangramento, endocardite, trombose e RPP) foi utilizada a curva de Kaplan-Meier. Foi aplicado, para comparar as curvas entre os grupos, o teste de Log-rank. Para analisar os desfechos foi utilizado o modelo de riscos proporcionais de Cox. N&#227;o foi considerada a an&#225;lise m&#250;ltipla de vari&#225;veis pois o modelo de sele&#231;&#227;o <italic>stepwise</italic> resultou no pr&#243;prio modelo de riscos proporcionais simples de Cox. Como medida de efeito, foi calculada a raz&#227;o entre taxas instant&#226;neas de incid&#234;ncias ( <italic>hazard ratio</italic> ), com seus respectivos intervalos, com 95% de confian&#231;a. O n&#237;vel de signific&#226;ncia estat&#237;stica adotado foi de 5%. Nos c&#225;lculos atuariais, empregou-se o programa R Core Team 2019.</p>
        <p>Foi utilizado o teste exato de Fisher para avaliar diferen&#231;as na taxa de mortalidade precoce entre os grupos, considerando a soma dos pacientes eleg&#237;veis e os seis exclu&#237;dos por &#243;bito em menos de 30 dias do procedimento. Esses seis pacientes n&#227;o foram considerados nas demais an&#225;lises. A an&#225;lise est&#225; robusta aos dados censurados, pois o valor de p continua n&#227;o significativo mesmo considerando todos os exclu&#237;dos por falta de seguimento maior de 30 dias, como &#243;bito precoce ou n&#227;o &#243;bito precoce.</p>
        <p>Para an&#225;lise da taxa de reopera&#231;&#227;o nos subgrupos divididos por idade (18-29 anos / 30-49 anos / &#8805; 50 anos) foi utilizado o teste de Bonferroni com refer&#234;ncia para o valor de p ajustado para 0,05/3 = 0,016666.</p>
      </sec>
    </sec>
    <sec sec-type="results">
      <title>Resultados</title>
      <sec>
        <title>Amostra</title>
        <p>Foram avaliados os dados de 221 pacientes submetidos &#224; troca da valva a&#243;rtica isolada. A mortalidade hospitalar, considerada at&#233; 30 dias de p&#243;s-operat&#243;rio foi de 2,7%, 6 pacientes do total de 221 da amostra. Treze pacientes tiveram perda de seguimento, correspondente a 5,8% da amostra total. Foram ent&#227;o contabilizados 202 pacientes eleg&#237;veis, dos quais 132 pertencentes ao grupo de biopr&#243;teses (65,3%), sendo 126 (95,5%) pr&#243;tese porcina e 6 (4,5%) pr&#243;tese de peric&#225;rdio bovino, e 70 ao grupo de pr&#243;tese mec&#226;nica (34,7%). Dados demonstrados na <xref rid="f01" ref-type="fig">figura 1</xref> .</p>
        <p>
          <fig id="f01">
            <label>Figura 1</label>
            <caption>
              <title>&#8211; Distribui&#231;&#227;o dos pacientes.</title>
            </caption>
            <graphic xlink:href="1678-4170-abc-117-01-0028-00135-gf01.tif"/></fig>
        </p>
        <p>A m&#233;dia de seguimento foi de 9,29 &#177; 3,8 anos, sendo que 74% dos pacientes foram acompanhados por mais de oito anos. O tempo de m&#225;ximo evolu&#231;&#227;o foi 14,25 anos para pr&#243;teses biol&#243;gicas e 14,34 anos para pr&#243;tese mec&#226;nica.</p>
        <p>As caracter&#237;sticas basais dos pacientes com biopr&#243;tese e pr&#243;tese mec&#226;nica foram semelhantes e podem ser observadas na <xref rid="t1" ref-type="table">tabela 1</xref> . O uso de anticoagula&#231;&#227;o, como esperado, foi mais prevalente no grupo submetido &#224; troca da valva a&#243;rtica por pr&#243;tese mec&#226;nica, com p &lt; 0,001. Todos os outros fatores n&#227;o foram estatisticamente diferentes entre os dois grupos: idade, sexo, etiologia da disfun&#231;&#227;o valvar, ritmo card&#237;aco e dados do ECO pr&#233;-operat&#243;rio (DDVE, DSVE, FEVE, PSAP).</p>
        <p>
          <table-wrap id="t1">
            <label>Tabela 1</label>
            <caption>
              <title>&#8211; Caracteriza&#231;&#227;o da amostra</title>
            </caption>
            <table frame="hsides" rules="groups">
              <colgroup>
                <col/>
                <col/>
                <col/>
                <col/>
              </colgroup>
              <thead>
                <tr>
                  <th align="left">Vari&#225;vel</th>
                  <th colspan="2">Grupo estudado</th>
                  <th>Valor de p*</th>
                </tr>
                <tr>
                  <th align="left" style="font-weight:normal"> </th>
                  <th>Pr&#243;tese biol&#243;gica</th>
                  <th>Pr&#243;tese mec&#226;nica</th>
                  <th align="left" style="font-weight:normal"> </th>
                </tr>
                <tr>
                  <th align="left" style="font-weight:normal"> </th>
                  <th>(N= 132)</th>
                  <th>(N= 70)</th>
                  <th align="left" style="font-weight:normal"> </th>
                </tr>
              </thead>
              <tbody>
                <tr>
                  <td>
                    <bold>Idade &#177; DP</bold>
                  </td>
                  <td align="center">50,78&#177;11,67</td>
                  <td align="center">47,67&#177;14,09</td>
                  <td align="center">0,116</td>
                </tr>
                <tr>
                  <td>
                    <bold>Sexo - n (%)</bold>
                  </td>
                  <td> </td>
                  <td> </td>
                  <td align="center">0,504</td>
                </tr>
                <tr>
                  <td> Masculino</td>
                  <td align="center">75,8%</td>
                  <td align="center">71,4%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td> Feminino</td>
                  <td align="center">24,2%</td>
                  <td align="center">28,6%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td>
                    <bold>Etiologia - n (%)</bold>
                  </td>
                  <td> </td>
                  <td> </td>
                  <td align="center">0,357</td>
                </tr>
                <tr>
                  <td> Degenerativa</td>
                  <td align="center">62,1%</td>
                  <td align="center">57,1%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td> Reum&#225;tica</td>
                  <td align="center">21,9%</td>
                  <td align="center">22,9%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td> Dilata&#231;&#227;o Aorta</td>
                  <td align="center">12,1%</td>
                  <td align="center">10%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td> Bic&#250;spide</td>
                  <td align="center">3,9%</td>
                  <td align="center">10%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td>
                    <bold>Ritmo ECG - n (%)</bold>
                  </td>
                  <td> </td>
                  <td> </td>
                  <td align="center">0,568</td>
                </tr>
                <tr>
                  <td> Sinusal</td>
                  <td align="center">80,3%</td>
                  <td align="center">84,3%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td> FA/Flutter</td>
                  <td align="center">19,7%</td>
                  <td align="center">15,7%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td>
                    <bold>Uso de ACO - n (%)</bold>
                  </td>
                  <td> </td>
                  <td> </td>
                  <td align="center">&lt; 0,001</td>
                </tr>
                <tr>
                  <td> Sim</td>
                  <td align="center">12,1%</td>
                  <td align="center">97,1%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td> N&#227;o</td>
                  <td align="center">87,9%</td>
                  <td align="center">2,9%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td colspan="4">
                    <bold>ECO pr&#233;-operat&#243;rio</bold>
                  </td>
                </tr>
                <tr>
                  <td> PSAP &#177; DP</td>
                  <td> </td>
                  <td> </td>
                  <td align="center">0,551</td>
                </tr>
                <tr>
                  <td> Sem HP</td>
                  <td align="center">78%</td>
                  <td align="center">82,6%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td> HP leve</td>
                  <td align="center">16,7%</td>
                  <td align="center">11,6%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td> HP moderada</td>
                  <td align="center">3,8%</td>
                  <td align="center">5,8%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td> HP grave</td>
                  <td align="center">1,5%</td>
                  <td align="center">0%</td>
                  <td> </td>
                </tr>
                <tr>
                  <td> FEVE &#177; DP</td>
                  <td align="center">58,51&#177;12,71</td>
                  <td align="center">61,68&#177;10,9</td>
                  <td align="center">0,067</td>
                </tr>
                <tr>
                  <td> DSVE &#177; DP</td>
                  <td align="center">41,01&#177;11,79</td>
                  <td align="center">40,06&#177;11,28</td>
                  <td align="center">0,547</td>
                </tr>
                <tr>
                  <td> DDVE &#177; DP</td>
                  <td align="center">60,92&#177;11,68</td>
                  <td align="center">60,74&#177;12,7</td>
                  <td align="center">0,923</td>
                </tr>
              </tbody>
            </table>
            <table-wrap-foot>
              <fn id="TFN1">
                <p>
                  <italic>* Valor de p&lt;0,05 considerado estatisticamente significativo. DP: desvio padr&#227;o; ECG: eletrocardiograma; FA: fibrila&#231;&#227;o atrial; ACO: anticoagula&#231;&#227;o com Marevan; ECO: ecocardiograma; PSAP: press&#227;o sist&#243;lica de art&#233;ria pulmonar; HP: hipertens&#227;o pulmonar; FEVE: fra&#231;&#227;o de eje&#231;&#227;o de ventr&#237;culo esquerdo; DSVE: di&#226;metro sist&#243;lico do ventr&#237;culo esquerdo; DDVE: di&#226;metro diast&#243;lico do ventr&#237;culo esquerdo. </italic>
                </p>
              </fn>
            </table-wrap-foot>
          </table-wrap>
        </p>
        <p>A mortalidade precoce (com menos de trinta dias p&#243;s cirurgia) foi de 2,7% que corresponde a seis pacientes de um total de 221 analisados. N&#227;o houve diferen&#231;a na mortalidade precoce entre os dois tipos de substituto (1,3% pr&#243;tese mec&#226;nica <italic>versus</italic> 3,5% pr&#243;tese biol&#243;gica; p = 0,666). Como o objetivo deste estudo foi comparar os pacientes com os dois tipos de pr&#243;tese (biol&#243;gica e mec&#226;nica) a longo prazo, esses seis pacientes foram exclu&#237;dos da an&#225;lise.</p>
      </sec>
      <sec>
        <title>Dados de sobrevida e reopera&#231;&#227;o</title>
        <p>A probabilidade de sobrevida livre de &#243;bito por qualquer causa e reopera&#231;&#227;o foi significativamente maior em pacientes tratados com pr&#243;tese biol&#243;gica em compara&#231;&#227;o com a pr&#243;tese mec&#226;nica (HR= 0,33; 95% intervalo de confian&#231;a [IC] 0,13-0,79; p= 0,013), como observado na <xref rid="f02" ref-type="fig">figura 2</xref> .</p>
        <p>
          <fig id="f02">
            <label>Figura 2</label>
            <caption>
              <title>&#8211; Curva de Kaplan-Meier para avaliar probabilidade de sobrevida livre de eventos (&#243;bito ou reopera&#231;&#227;o).</title>
            </caption>
            <graphic xlink:href="1678-4170-abc-117-01-0028-00135-gf02.tif"/></fig>
        </p>
        <p>Foram observados oito &#243;bitos num per&#237;odo de 10 anos no grupo de pacientes portadores de pr&#243;tese biol&#243;gica e cinco no grupo de pr&#243;tese mec&#226;nica. Esses dados correspondem a um percentual ajustado de 6,11% de mortalidade para o grupo de pr&#243;tese biol&#243;gica e 7,9% para pr&#243;tese mec&#226;nica (p=0,68).</p>
        <p>Por outro lado, a an&#225;lise de reopera&#231;&#227;o isolada evidenciou uma diferen&#231;a significativa a favor da pr&#243;tese mec&#226;nica (HR=0,062; IC= 0,008-0,457; p=0,006). Num per&#237;odo de 10 anos, dezenove pacientes portadores de pr&#243;tese biol&#243;gica foram reoperados, correspondendo a um percentual de 21,24%. N&#227;o teve nenhum evento registrado para o grupo de pr&#243;tese mec&#226;nica.</p>
        <p>A reopera&#231;&#227;o foi avaliada de acordo com a faixa et&#225;ria, separados por subgrupos &lt;30 anos, entre 30 e 49 anos e &#8805;50 anos. A probabilidade livre de reopera&#231;&#227;o foi menor para o grupo &lt;30 anos em compara&#231;&#227;o com o grupo entre 30-49 anos (HR= 6,69; IC= 1,88-23,8; p=0,003) e tamb&#233;m em compara&#231;&#227;o com o grupo &#8805; 50 anos (HR= 3,51; IC= 1,37-9,03; p=0,008). Por sua vez, o grupo &#8805;50 anos n&#227;o teve diferen&#231;a em rela&#231;&#227;o ao grupo entre 30-49 anos (HR= 0,50; IC= 0,16-1,50; p=0,219). Esses dados podem ser observados na <xref rid="f03" ref-type="fig">figura 3</xref> .</p>
        <p>
          <fig id="f03">
            <label>Figura 3</label>
            <caption>
              <title>&#8211; Curva de Kaplan-Meier para avaliar probabilidade de sobrevida livre de reopera&#231;&#227;o separados por subgrupos de &gt;18 a &lt;30 anos, &#8805; 30 a 49 anos e &#8805; 50 anos.</title>
            </caption>
            <graphic xlink:href="1678-4170-abc-117-01-0028-00135-gf03.tif"/></fig>
        </p>
      </sec>
      <sec>
        <title>Dados de eventos adversos</title>
        <p>O desfecho secund&#225;rio composto de AVC, sangramento, endocardite, trombose e RPP foi semelhante nos dois grupos (HR=1,20; IC 95%= 0,74-1,93; p=0,44), como observado na <xref rid="f04" ref-type="fig">figura 4</xref> .</p>
        <p>
          <fig id="f04">
            <label>Figura 4</label>
            <caption>
              <title>&#8211; Curva de Kaplan-Meier para avaliar probabilidade de sobrevida livre de desfechos secund&#225;rios (AVC, sangramento, endocardite, trombose e RPP).</title>
            </caption>
            <graphic xlink:href="1678-4170-abc-117-01-0028-00135-gf04.tif"/></fig>
        </p>
        <p>O gr&#225;fico de Forest plot abaixo ( <xref rid="f05" ref-type="fig">figura 5</xref> ) representa a an&#225;lise do desfecho secund&#225;rio realizado pelo <italic>hazard ratio.</italic> </p>
        <p>
          <fig id="f05">
            <label>Figura 5</label>
            <caption>
              <title>&#8211; Gr&#225;fico de Forest Plot do efeito dos eventos adversos em rela&#231;&#227;o ao tipo de pr&#243;tese (mec&#226;nica ou biol&#243;gica).</title>
            </caption>
            <graphic xlink:href="1678-4170-abc-117-01-0028-00135-gf05.tif"/></fig>
        </p>
        <p>O risco de sangramento foi significativamente maior em pacientes tratados com pr&#243;tese mec&#226;nica em compara&#231;&#227;o com a pr&#243;tese biol&#243;gica (HR=3,65; IC 95%= 1,43-9,29; p=0,0064). Foi observado um percentual ajustado pelos dados censurados de sangramento em 10 anos de 5,38% de sangramento para o grupo de pr&#243;tese biol&#243;gica e 20,97% para o grupo de pr&#243;tese mec&#226;nica.</p>
        <p>A taxa de AVC em 10 anos foi de 14.10% para o grupo de pr&#243;tese biol&#243;gica e 11.56% para o grupo de pr&#243;tese mec&#226;nica, p=0,47.</p>
        <p>O risco de RPP foi semelhante entre o grupo de pr&#243;tese biol&#243;gica e pr&#243;tese mec&#226;nica (HR=0,71; IC 95%= 0,22-2,24; p=0,56). Foi observado um percentual ajustado pelos dados censurados em 10 anos de 6.53% de RPP para o grupo de pr&#243;tese biol&#243;gica e 3.38% para o grupo de pr&#243;tese mec&#226;nica.</p>
        <p>O risco de endocardite foi semelhante entre o grupo de pr&#243;tese biol&#243;gica e pr&#243;tese mec&#226;nica (HR=1,30; IC 95%= 0,46-3,66; p=0,61). Foi observado um percentual ajustado pelos dados censurados em 10 anos de 6.12% de endocardite para o grupo de pr&#243;tese biol&#243;gica e 1.57% para o grupo de pr&#243;tese mec&#226;nica.</p>
        <p>O risco de trombose foi semelhante entre o grupo de pr&#243;tese biol&#243;gica e pr&#243;tese mec&#226;nica (p=0,1). Foi observado um percentual ajustado pelos dados censurados em 10 anos de 5.06% de trombose para o grupo de pr&#243;tese biol&#243;gica n&#227;o teve nenhum evento registrado para o grupo de pr&#243;tese mec&#226;nica.</p>
        <p>A taxa de DPP observada foi de 3,78% para o grupo de pr&#243;tese biol&#243;gica e n&#227;o teve nenhum evento registrado para o grupo de pr&#243;tese mec&#226;nica. A aus&#234;ncia de evento no grupo da pr&#243;tese mec&#226;nica n&#227;o permitiu uma an&#225;lise estat&#237;stica mais detalhada. Dados demostrados na Tabela 2.</p>
      </sec>
    </sec>
    <sec sec-type="discussion">
      <title>Discuss&#227;o</title>
      <p>Mais de 30 anos ap&#243;s a introdu&#231;&#227;o das pr&#243;teses modernas, a escolha entre biol&#243;gicas e mec&#226;nicas permanece controversa. S&#227;o poucos os trabalhos randomizados, controlados e com grande n&#250;mero de pacientes para guiar de forma definitiva a escolha da melhor pr&#243;tese. O n&#237;vel de evid&#234;ncia na maioria das recomenda&#231;&#245;es das diretrizes &#233; baixo (n&#237;vel C), ficando a escolha baseada em dados limitados, na experi&#234;ncia cl&#237;nica e no bom senso. Espera-se que este trabalho auxilie no conhecimento acerca da evolu&#231;&#227;o dos tipos de pr&#243;tese para essa amostra espec&#237;fica que nos deparamos.</p>
      <p>No presente estudo buscamos avaliar a cirurgia de troca da valva a&#243;rtica por pr&#243;tese biol&#243;gica ou mec&#226;nica em um grupo de pacientes atendidos pelo Sistema &#218;nico de Sa&#250;de (SUS). A doen&#231;a degenerativa foi a principal causa de valvopatia, seguida pela doen&#231;a reum&#225;tica com cerca de 22% dos casos. Esse predom&#237;nio epidemiol&#243;gico da doen&#231;a degenerativa &#233; semelhante a pa&#237;ses desenvolvidos, por&#233;m o motivo da etiologia reum&#225;tica n&#227;o ter sido mais expressiva pode ser justificado pela sele&#231;&#227;o de pacientes com limite de idade superior a 18 anos e de se tratar de um estudo exclusivo da valva a&#243;rtica.<sup><xref rid="B4" ref-type="bibr">4</xref></sup></p>
      <p>Chama aten&#231;&#227;o que cerca de 80% dos pacientes, nos dois grupos, apresentavam-se em ritmo sinusal. Cerca de 19,7% dos pacientes do grupo de pr&#243;tese biol&#243;gica apresentavam fibrila&#231;&#227;o atrial, por&#233;m apenas 12,1% estavam em uso de anticoagula&#231;&#227;o. Dois pacientes do grupo de pr&#243;tese mec&#226;nica tamb&#233;m estavam sem uso de anticoagula&#231;&#227;o, apesar das orienta&#231;&#245;es e risco de trombose, sendo que um evoluiu para &#243;bito e o outro para AVC. Esses dados refletem a dificuldade de realiza&#231;&#227;o de anticoagula&#231;&#227;o na popula&#231;&#227;o menos favorecida do pa&#237;s. N&#227;o houve diferen&#231;a estatisticamente significativa dos par&#226;metros ecocardiogr&#225;ficos pr&#233;-operat&#243;rios. A maioria dos pacientes apresentava fun&#231;&#227;o ventricular preservada e sem hipertens&#227;o pulmonar importante.</p>
      <p>A coorte estudada constitui uma amostra com m&#233;dia de idade de 50 anos. O risco de reopera&#231;&#227;o foi significativamente maior em pacientes com biopr&#243;tese, principalmente para os pacientes menores de 30 anos. As curvas come&#231;am a se distanciar a partir do quarto ano do implante da pr&#243;tese e tornam-se mais evidentes ap&#243;s os 8 anos, sendo que 50% dos pacientes com menos de 30 anos j&#225; tinham a indica&#231;&#227;o de reopera&#231;&#227;o em 10 anos de evolu&#231;&#227;o. Em uma m&#233;dia de 10 anos houve uma &#250;nica indica&#231;&#227;o de reopera&#231;&#227;o no grupo de pr&#243;tese mec&#226;nica. Da mesma forma Hammermeister et al. encontraram maior n&#250;mero de interven&#231;&#245;es no grupo que recebeu pr&#243;tese valvar biol&#243;gica em posi&#231;&#227;o a&#243;rtica em compara&#231;&#227;o com os que receberam pr&#243;tese mec&#226;nica (29% <italic>versus</italic> 10%; p = 0,004).<sup><xref rid="B5" ref-type="bibr">5</xref></sup> Vale ressaltar que as taxas de reopera&#231;&#227;o n&#227;o capturam totalmente o risco de degenera&#231;&#227;o estrutural da pr&#243;tese, pois alguns pacientes com deteriora&#231;&#227;o estrutural significativa n&#227;o s&#227;o considerados candidatos &#224; reopera&#231;&#227;o devido ao alto risco cir&#250;rgico.</p>
      <p>A mortalidade tardia foi semelhante entre os dois grupos, com valores de percentual ajustado muito pr&#243;ximos, 6,11% para pr&#243;tese biol&#243;gica e 7,93% para pr&#243;tese mec&#226;nica, p = 0,68. Estudos mais recentes produzem resultados mistos, com uma tend&#234;ncia a menores taxas de mortalidade com pr&#243;tese mec&#226;nica em grupos et&#225;rios mais jovens (menores que 55 anos).<sup><xref rid="B6" ref-type="bibr">6</xref></sup></p>
      <p>Sangramento ocorreu nos dois grupos, visto que 97,1% dos portadores de pr&#243;tese mec&#226;nica estavam em uso de anticoagula&#231;&#227;o e 12,1% do grupo de pr&#243;tese biol&#243;gica, embora nos portadores de pr&#243;tese mec&#226;nica tenha sido significativamente maior (p = 0,0064). N&#227;o foi registrado nenhum sangramento fatal ou AVC hemorr&#225;gico. Como exemplo, no Veterans Affairs Cooperative Study, 575 pacientes foram aleatoriamente designados para terapia com uma pr&#243;tese mec&#226;nica ou biol&#243;gica. A probabilidade de sangramento em 11 anos foi significativamente maior nas v&#225;lvulas mec&#226;nicas (42% <italic>versus</italic> 26%).<sup><xref rid="B7" ref-type="bibr">7</xref></sup></p>
      <p>Na presente coorte, n&#227;o houve diferen&#231;a estatisticamente significativa no risco de endocardite. Durante o primeiro ano de p&#243;s-operat&#243;rio, a infec&#231;&#227;o geralmente ocorre com igual frequ&#234;ncia nos dispositivos mec&#226;nicos e biol&#243;gicos. Durante o seguimento a longo prazo, as taxas de endocardite com pr&#243;teses biol&#243;gicas s&#227;o semelhantes ou ligeiramente superiores &#224;s das pr&#243;teses mec&#226;nicas, por&#233;m os dados dispon&#237;veis ainda s&#227;o muito limitados.<sup><xref rid="B8" ref-type="bibr">8</xref></sup></p>
      <p>A literatura demonstra maior taxa de trombose de pr&#243;tese em pacientes com pr&#243;tese mec&#226;nica <italic>versus</italic> pr&#243;tese biol&#243;gica e destaca a necessidade de ser manter terapia anticoagulante cont&#237;nua nesses pacientes.<sup><xref rid="B9" ref-type="bibr">9</xref></sup> Esse dado vai de encontro ao observado no presente estudo, em que n&#227;o houve diferen&#231;a estatisticamente significativa entre as duas pr&#243;teses com valores de percentual ajustado de 5,06% para pr&#243;tese biol&#243;gica e nenhum caso registrado para pr&#243;tese mec&#226;nica. Esse dado pode ser justificado pelo atendimento dos pacientes do estudo em centro especializado de anticoagula&#231;&#227;o. Para o controle de anticoagula&#231;&#227;o, Chiquette et al.,<sup><xref rid="B10" ref-type="bibr">10</xref></sup> comparam o atendimento convencional em consult&#243;rio com o acompanhamento em cl&#237;nicas especializadas. Nas cl&#237;nicas especializadas foram encontradas menores taxas de ocorr&#234;ncia de eventos tromboemb&#243;licos (maiores, menores e fatais).<sup><xref rid="B10" ref-type="bibr">10</xref></sup></p>
      <p>N&#227;o houve diferen&#231;a de risco de AVC isqu&#234;mico entre os dois grupos estudados (percentual ajustado de 14,1% para a pr&#243;tese biol&#243;gica <italic>versus</italic> 11,5% para pr&#243;tese mec&#226;nica aos 10 anos; p = 0,47). Na literatura encontramos dados em que o risco de complica&#231;&#245;es tromboemb&#243;licas &#233; geralmente semelhante ou menor em pacientes com pr&#243;tese biol&#243;gica em compara&#231;&#227;o com pacientes com pr&#243;tese mec&#226;nica tratada com anticoagula&#231;&#227;o. Em um exemplo de um estudo observacional, o risco cumulativo de AVC entre pacientes de 45 a 54 anos de idade submetidos a troca da valva a&#243;rtica foi significativamente menor entre aqueles com pr&#243;tese biol&#243;gica em compara&#231;&#227;o com pr&#243;tese mec&#226;nica (aproximadamente 10% <italic>versus</italic> 16% aos 15 anos; HR = 0,64; IC 95% 0,46-0,86; p &lt; 0,05).<sup><xref rid="B6" ref-type="bibr">6</xref></sup> A elevada taxa de AVC encontrada nessa coorte possivelmente se deve ao fato de a maioria dos pacientes ter alta preval&#234;ncia de comorbidades associadas, interferindo nas taxas de AVC em ambos os grupos e tamb&#233;m pela aus&#234;ncia de anticoagula&#231;&#227;o em pacientes em ritmo de fibrila&#231;&#227;o atrial e aus&#234;ncia de dados de controle do tempo de protrombina dos pacientes analisados.</p>
      <p>N&#227;o houve diferen&#231;a estatisticamente significativa para o risco de RPP entre as duas pr&#243;teses em posi&#231;&#227;o a&#243;rtica. Foi observado um percentual ajustado pelos dados censurados em 10 anos de 6,53% de RPP para o grupo de pr&#243;tese biol&#243;gica e 3,38% para o grupo de pr&#243;tese mec&#226;nica, dados corroborados pela literatura que estima uma incid&#234;ncia de 2% a 10% na posi&#231;&#227;o a&#243;rtica. Como exemplo, em estudos com ecocardiografia transesof&#225;gica (ETE) ap&#243;s cirurgias de troca valvar, a incid&#234;ncia de RPP variou de 3% a 6% com uma tend&#234;ncia estat&#237;stica a maior preval&#234;ncia em pr&#243;teses mec&#226;nicas.<sup><xref rid="B11" ref-type="bibr">11</xref></sup></p>
      <p>A DPP foi observada em 3,78% dos indiv&#237;duos com pr&#243;tese biol&#243;gica e em nenhum paciente do grupo de pr&#243;tese mec&#226;nica, possibilitando apenas uma an&#225;lise simples descritiva. Esse n&#250;mero ficou aqu&#233;m do evidenciado na literatura, em que pode chegar a cerca de 20% a 70%.<sup><xref rid="B12" ref-type="bibr">12</xref></sup>De acordo com a revis&#227;o sistem&#225;tica da European Heart Journal acerca do impacto a longo prazo do DPP, que avaliou 34 estudos com um total de 27186 pacientes, sua presen&#231;a esteve associada a um decr&#233;scimo de sobrevida a longo prazo (HR = 1,34, 95% CI = 1,18-1,51).<sup><xref rid="B13" ref-type="bibr">13</xref></sup> Quando comparada a incid&#234;ncia entre pr&#243;tese mec&#226;nicas e biol&#243;gicas, a DPP parece ter maior probabilidade de ocorrer com biopr&#243;teses, j&#225; que pr&#243;teses mec&#226;nicas geralmente t&#234;m maiores orif&#237;cios valvares efetivos comparados com pr&#243;teses biol&#243;gicas devido ao espa&#231;o ocupado pelas suas hastes de suporte. Em pacientes com anel a&#243;rtico pequeno, o tamanho do orif&#237;cio valvar efetivo &#233; crucial para otimizar o desempenho hemodin&#226;mico da pr&#243;tese e, assim, evitar a ocorr&#234;ncia de DPP. Em alguns casos, pacientes com um pequeno anel podem se beneficiar de uma pr&#243;tese mec&#226;nica.<sup><xref rid="B1" ref-type="bibr">1</xref></sup></p>
      <p>No presente estudo foi encontrada uma m&#233;dia de 202 dias entre a indica&#231;&#227;o da cirurgia e sua realiza&#231;&#227;o, por&#233;m com um padr&#227;o de distribui&#231;&#227;o bastante heterog&#234;neo. Os diferentes perfis de indica&#231;&#245;es cir&#250;rgicas e caracter&#237;sticas dos pacientes justificam essa heterogeneidade e constituem uma contribui&#231;&#227;o importante no tempo de espera do paciente pela cirurgia.</p>
      <sec>
        <title>Limita&#231;&#245;es do estudo</title>
        <p>Este trabalho &#233; um estudo n&#227;o randomizado. Seus dados t&#234;m valida&#231;&#227;o externa restrita, por&#233;m seus resultados podem servir de base para outros estudos anal&#237;ticos e prospectivos, a fim de se obter dados mais consistentes. Tamb&#233;m tem como limita&#231;&#227;o sua realiza&#231;&#227;o em um &#250;nico centro, amostra insuficiente para eventos raros e perda de seguimento.</p>
        <p>Neste estudo n&#227;o foi avaliada a mortalidade relacionada &#224; reopera&#231;&#227;o, o que talvez subestime a mortalidade do grupo de biopr&#243;tese. Tamb&#233;m n&#227;o foi avaliado o controle do tempo de protrombina dos pacientes em uso de anticoagula&#231;&#227;o, o que dificulta compreender melhor a elevada incid&#234;ncia de AVC isqu&#234;mico nos dois grupos.</p>
      </sec>
    </sec>
    <sec sec-type="conclusions">
      <title>Conclus&#227;o</title>
      <p>A probabilidade de sobrevida livre de &#243;bito e reopera&#231;&#227;o, em pacientes com m&#233;dia de idade de 50 anos, operados em hospital terci&#225;rio do SUS do Estado de S&#227;o Paulo, foi significativamente maior nos pacientes com pr&#243;tese mec&#226;nica, &#224;s custas da maior durabilidade da pr&#243;tese. N&#227;o houve diferen&#231;a de mortalidade em 10 anos entre os dois grupos. A necessidade de reopera&#231;&#227;o foi significativamente maior nos pacientes com biopr&#243;tese e com idade inferior a 30 anos. N&#227;o houve diferen&#231;a entre os grupos em rela&#231;&#227;o aos eventos adversos combinados. Embora n&#227;o tenha havido nenhum sangramento fatal, pacientes com pr&#243;tese mec&#226;nica apresentaram mais sangramento.</p>
    </sec>
  </body>
  <back>
    <ack>
      <title>Agradecimentos</title>
      <p>Agradecimento especial ao setor de valvopatias do Instituto Dante Pazzanese de Cardiologia por prestar servi&#231;o m&#233;dico &#224; comunidade e contribuir para o desenvolvimento de pesquisa nessa &#225;rea. Agradecimento &#224; dire&#231;&#227;o do hospital e as equipes m&#233;dicas setoriais pelo trabalho em conjunto em prol do paciente, colaborando com a realiza&#231;&#227;o de exames complementares e an&#225;lise conjunta do caso cl&#237;nico.</p>
      <p>Agradecimento especial aos pacientes que depositam sua confian&#231;a na equipe multidisciplinar do hospital para cuidado com sua sa&#250;de e possibilitam um aperfei&#231;oamento cont&#237;nuo.</p>
    </ack>
    <ref-list>
      <title>Refer&#234;ncias</title>
      <ref id="B1">
        <label>1</label>
        <mixed-citation>1. Head SJ, &#199;elik M, Kappetein AP. Mechanical versus bioprosthetic aortic valve replacement. Eur Heart J. 2017;38(28):2183-91. doi:10.1093/eurheartj/ehx141</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Head</surname>
              <given-names>SJ</given-names>
            </name>
            <name>
              <surname>&#199;elik</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Kappetein</surname>
              <given-names>AP</given-names>
            </name>
          </person-group>
          <article-title>Mechanical versus bioprosthetic aortic valve replacement</article-title>
          <source> Eur Heart J </source>
          <year>2017</year>
          <volume>38</volume>
          <issue>28</issue>
          <fpage>2183</fpage>
          <lpage>2191</lpage>
          <pub-id pub-id-type="doi">10.1093/eurheartj/ehx141</pub-id>
        </element-citation>
      </ref>
      <ref id="B2">
        <label>2</label>
        <mixed-citation>2. Schnittman SR, Adams DH, Itagaki S, Toyoda N, Egorova NN, Chikwe J. Bioprosthetic aortic valve replacement: Revisiting prosthesis choice in patients younger than 50 years old. J Thorac Cardiovasc Surg. 2018;155(2):539-47.e9. doi:10.1016/j.jtcvs.2017.08.121</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Schnittman</surname>
              <given-names>SR</given-names>
            </name>
            <name>
              <surname>Adams</surname>
              <given-names>DH</given-names>
            </name>
            <name>
              <surname>Itagaki</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Toyoda</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Egorova</surname>
              <given-names>NN</given-names>
            </name>
            <name>
              <surname>Chikwe</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>Bioprosthetic aortic valve replacement: Revisiting prosthesis choice in patients younger than 50 years old</article-title>
          <source> J Thorac Cardiovasc Surg </source>
          <year>2018</year>
          <volume>155</volume>
          <issue>2</issue>
          <fpage>539</fpage>
          <lpage>547</lpage>
          <comment>e9</comment>
          <pub-id pub-id-type="doi">10.1016/j.jtcvs.2017.08.121</pub-id>
        </element-citation>
      </ref>
      <ref id="B3">
        <label>3</label>
        <mixed-citation>3. Maria M, Passos B, Carneiro EM, Martins A, Alves M. Perfil Epidemiol&#243;gico De Pacientes Submetidos &#192; Cirurgia Card&#237;aca Em Hospital Universit&#225;rio Do Piau&#237;. 2017;8:173-7.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Maria</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Passos</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Carneiro</surname>
              <given-names>EM</given-names>
            </name>
            <name>
              <surname>Martins</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Alves</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Perfil Epidemiol&#243;gico De Pacientes Submetidos &#192; Cirurgia Card&#237;aca Em Hospital Universit&#225;rio Do Piau&#237;</article-title>
          <year>2017</year>
          <volume>8</volume>
          <fpage>173</fpage>
          <lpage>177</lpage>
        </element-citation>
      </ref>
      <ref id="B4">
        <label>4</label>
        <mixed-citation>4. Fernandes AMS, Bitencourt LS, Lessa IN. Impact of socio-economic profile on the prosthesis type choice used on heart surgery. Rev Bras Cir Cardiovasc. 2012;27(2):211-6. doi:10.5935/1678-9741.20120056</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Fernandes</surname>
              <given-names>AMS</given-names>
            </name>
            <name>
              <surname>Bitencourt</surname>
              <given-names>LS</given-names>
            </name>
            <name>
              <surname>Lessa</surname>
              <given-names>IN</given-names>
            </name>
          </person-group>
          <article-title>Impact of socio-economic profile on the prosthesis type choice used on heart surgery</article-title>
          <source> Rev Bras Cir Cardiovasc </source>
          <year>2012</year>
          <volume>27</volume>
          <issue>2</issue>
          <fpage>211</fpage>
          <lpage>216</lpage>
          <pub-id pub-id-type="doi">10.5935/1678-9741.20120056</pub-id>
        </element-citation>
      </ref>
      <ref id="B5">
        <label>5</label>
        <mixed-citation>5. Hammermeister KE, Henderson WG, Burchfiel CM. Comparison of Outcome After Valve Replacement With a Bioprosthesis Versus a Mechanical Prosthesis : Initial 5 Year Results of a Randomized Trial. 1987;10(4):919-32. doi:10.1016/S0735-1097(87)80263-2</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Hammermeister</surname>
              <given-names>KE</given-names>
            </name>
            <name>
              <surname>Henderson</surname>
              <given-names>WG</given-names>
            </name>
            <name>
              <surname>Burchfiel</surname>
              <given-names>CM</given-names>
            </name>
          </person-group>
          <article-title>Comparison of Outcome After Valve Replacement With a Bioprosthesis Versus a Mechanical Prosthesis : Initial 5 Year Results of a Randomized Trial</article-title>
          <year>1987</year>
          <volume>10</volume>
          <issue>4</issue>
          <fpage>919</fpage>
          <lpage>932</lpage>
          <pub-id pub-id-type="doi">10.1016/S0735-1097(87)80263-2</pub-id>
        </element-citation>
      </ref>
      <ref id="B6">
        <label>6</label>
        <mixed-citation>6. Goldstone AB, Chiu P, Baiocchi M. Mechanical or Biologic Prostheses for Aortic-Valve and Mitral-Valve Replacement. N Engl J Med. 2017;377(19):1847-57. doi:10.1056/NEJMoa1613792</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Goldstone</surname>
              <given-names>AB</given-names>
            </name>
            <name>
              <surname>Chiu</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Baiocchi</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Mechanical or Biologic Prostheses for Aortic-Valve and Mitral-Valve Replacement</article-title>
          <source> N Engl J Med </source>
          <year>2017</year>
          <volume>377</volume>
          <issue>19</issue>
          <fpage>1847</fpage>
          <lpage>1857</lpage>
          <pub-id pub-id-type="doi">10.1056/NEJMoa1613792</pub-id>
        </element-citation>
      </ref>
      <ref id="B7">
        <label>7</label>
        <mixed-citation>7. Lund O, Bland M. Risk-corrected impact of mechanical versus bioprosthetic valves on long-term mortality after aortic valve replacement. J Thorac Cardiovasc Surg. 2006;132(1):20-6. doi:10.1016/j.jtcvs.2006.01.043</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Lund</surname>
              <given-names>O</given-names>
            </name>
            <name>
              <surname>Bland</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Risk-corrected impact of mechanical versus bioprosthetic valves on long-term mortality after aortic valve replacement</article-title>
          <source> J Thorac Cardiovasc Surg </source>
          <year>2006</year>
          <volume>132</volume>
          <issue>1</issue>
          <fpage>20</fpage>
          <lpage>26</lpage>
          <pub-id pub-id-type="doi">10.1016/j.jtcvs.2006.01.043</pub-id>
        </element-citation>
      </ref>
      <ref id="B8">
        <label>8</label>
        <mixed-citation>8. Hammermeister KE, Sethi GK, Henderson WG, Oprian C, Kim T, Rahimtoola S; for the Veterans Affairs Cooperative Study on Valvular Heart Disease. A comparison of outcomes in men 11 years after heart-valve-replacement with a mechanical valve or bioprosthesis. N Engl J Med.1993;328(18):1289-96.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Hammermeister</surname>
              <given-names>KE</given-names>
            </name>
            <name>
              <surname>Sethi</surname>
              <given-names>GK</given-names>
            </name>
            <name>
              <surname>Henderson</surname>
              <given-names>WG</given-names>
            </name>
            <name>
              <surname>Oprian</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Kim</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Rahimtoola</surname>
              <given-names>S</given-names>
            </name>
            <collab>for the Veterans Affairs Cooperative Study on Valvular Heart Disease</collab>
          </person-group>
          <article-title>A comparison of outcomes in men 11 years after heart-valve-replacement with a mechanical valve or bioprosthesis</article-title>
          <source> N Engl J Med </source>
          <year>1993</year>
          <volume>328</volume>
          <issue>18</issue>
          <fpage>1289</fpage>
          <lpage>1296</lpage>
        </element-citation>
      </ref>
      <ref id="B9">
        <label>9</label>
        <mixed-citation>9. Amsterdam EA, Wenger NK, Brindis RG, Casey Jr DE, Ganiats TG, Holmes Jr DR, et al. 2014 AHA/ACC guideline for the management of patients with non-ST- elevation acute coronary syndrome. Circulation. 2014;130(25):2354-94.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Amsterdam</surname>
              <given-names>EA</given-names>
            </name>
            <name>
              <surname>Wenger</surname>
              <given-names>NK</given-names>
            </name>
            <name>
              <surname>Brindis</surname>
              <given-names>RG</given-names>
            </name>
            <name>
              <surname>Casey</surname>
              <given-names>DE</given-names>
              <suffix>Jr</suffix>
            </name>
            <name>
              <surname>Ganiats</surname>
              <given-names>TG</given-names>
            </name>
            <name>
              <surname>Holmes</surname>
              <given-names>DR</given-names>
              <suffix>Jr</suffix>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>2014 AHA/ACC guideline for the management of patients with non-ST- elevation acute coronary syndrome</article-title>
          <source> Circulation </source>
          <year>2014</year>
          <volume>130</volume>
          <issue>25</issue>
          <fpage>2354</fpage>
          <lpage>2394</lpage>
        </element-citation>
      </ref>
      <ref id="B10">
        <label>10</label>
        <mixed-citation>10. Chiquette E, Amato MG, Bussey HI. Comparison of an Anticoagulation Clinic With Usual Medical Care. Arch Intern Med. 1998;158(15):1641-7. 2015;158:1641-7.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Chiquette</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Amato</surname>
              <given-names>MG</given-names>
            </name>
            <name>
              <surname>Bussey</surname>
              <given-names>HI</given-names>
            </name>
          </person-group>
          <article-title>Comparison of an Anticoagulation Clinic With Usual Medical Care</article-title>
          <source> Arch Intern Med </source>
          <year>1998</year>
          <volume>158</volume>
          <issue>15</issue>
          <fpage>1641</fpage>
          <lpage>1647</lpage>
          <comment>2015;158:1641-7</comment>
        </element-citation>
      </ref>
      <ref id="B11">
        <label>11</label>
        <mixed-citation>11. Pinheiro CP, Rezek D, Costa EP, et al. Paravalvular regurgitation: Clinical outcomes in surgical and percutaneous treatments. Arq Bras Cardiol. 2016;107(1):55-62. doi:10.5935/abc.20160086</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Pinheiro</surname>
              <given-names>CP</given-names>
            </name>
            <name>
              <surname>Rezek</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Costa</surname>
              <given-names>EP</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Paravalvular regurgitation: Clinical outcomes in surgical and percutaneous treatments</article-title>
          <source> Arq Bras Cardiol </source>
          <year>2016</year>
          <volume>107</volume>
          <issue>1</issue>
          <fpage>55</fpage>
          <lpage>62</lpage>
          <pub-id pub-id-type="doi">10.5935/abc.20160086</pub-id>
        </element-citation>
      </ref>
      <ref id="B12">
        <label>12</label>
        <mixed-citation>12. Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: Definition, clinical impact, and prevention. Heart. 2006;92(8):1022-9. doi:10.1136/hrt.2005.067363</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Pibarot</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Dumesnil</surname>
              <given-names>JG</given-names>
            </name>
          </person-group>
          <article-title>Prosthesis-patient mismatch: Definition, clinical impact, and prevention</article-title>
          <source> Heart </source>
          <year>2006</year>
          <volume>92</volume>
          <issue>8</issue>
          <fpage>1022</fpage>
          <lpage>1029</lpage>
          <pub-id pub-id-type="doi">10.1136/hrt.2005.067363</pub-id>
        </element-citation>
      </ref>
      <ref id="B13">
        <label>13</label>
        <mixed-citation>13. Head SJ, Mokhles MM, Osnabrugge RLJ, et al. The impact of prosthesispatient mismatch on long-term survival after aortic valve replacement: A systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years. Eur Heart J. 2012;33(12):1518-29. doi:10.1093/eurheartj/ehs003</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Head</surname>
              <given-names>SJ</given-names>
            </name>
            <name>
              <surname>Mokhles</surname>
              <given-names>MM</given-names>
            </name>
            <name>
              <surname>Osnabrugge</surname>
              <given-names>RLJ</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>The impact of prosthesispatient mismatch on long-term survival after aortic valve replacement: A systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years</article-title>
          <source> Eur Heart J </source>
          <year>2012</year>
          <volume>33</volume>
          <issue>12</issue>
          <fpage>1518</fpage>
          <lpage>1529</lpage>
          <pub-id pub-id-type="doi">10.1093/eurheartj/ehs003</pub-id>
        </element-citation>
      </ref>
    </ref-list>
    <fn-group>
      <fn fn-type="other">
        <p>Vincula&#231;&#227;o acad&#234;mica</p>
        <p>Este artigo &#233; parte de disserta&#231;&#227;o de mestrado de Larissa Ventura Ribeiro Bruscky pela Universidade de S&#227;o Paulo.</p>
      </fn>
      <fn fn-type="supported-by" id="fn4">
        <p><bold>Fontes de financiamento</bold>:  O presente estudo n&#227;o teve fontes de financiamento externas.</p>
      </fn>
    </fn-group>
  </back>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Late Outcomes of Aortic Valve Replacement with Bioprosthesis and Mechanical Prosthesis</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-3799-9466</contrib-id>
          <name>
            <surname>Bruscky</surname>
            <given-names>Larissa Ventura Ribeiro</given-names>
          </name>
          <xref ref-type="aff" rid="aff1001">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Gun</surname>
            <given-names>Carlos</given-names>
          </name>
          <xref ref-type="aff" rid="aff1001">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0001-7180-5779</contrib-id>
          <name>
            <surname>Ramos</surname>
            <given-names>Auristela Isabel de Oliveira</given-names>
          </name>
          <xref ref-type="aff" rid="aff1001">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0003-1996-4144</contrib-id>
          <name>
            <surname>Morais</surname>
            <given-names>Alice Lemos</given-names>
          </name>
          <xref ref-type="aff" rid="aff1001">
            <sup>1</sup>
          </xref>
        </contrib>
      </contrib-group>
      <aff id="aff1001">
        <label>1</label>
        <country country="BR">Brasil</country>
        <institution content-type="original">Instituto Dante Pazzanese de Cardiologia, S&#227;o Paulo, SP &#8211; Brasil</institution>
      </aff>
      <author-notes>
        <corresp id="c01001"><bold>Mailing Address: Larissa Ventura Ribeiro Bruscky</bold> &#8226; Instituto Dante Pazzanese de Cardiologia &#8211; Av. Dr. Dante Pazzanese, 500. Postal Code 04012-909, Vila Mariana, S&#227;o Paulo, SP &#8211; Brazil E-mail: larissaventurar@gmail.com</corresp>
        <fn id="fn1001">
          <p>Author Contributions</p>
          <p>Conception and design of the research, Writing of the manuscript and Critical revision of the manuscript for intellectual content: Bruscky LVR, Gun C, Ramos AIO; Acquisition of data: Bruscky LVR; Analysis and interpretation of the data: Bruscky LVR, Gun C, Ramos AIO, Morais AL; Statistical analysis: Morais AL.</p>
          <p>Potential Conflict of Interest</p>
          <p>No potential conflict of interest relevant to this article was reported.</p>
        </fn>
      </author-notes>
      <abstract>
        <title>Abstract</title>
        <sec>
          <title>Background</title>
          <p>Despite constant improvement and refinement of the prostheses, the decision between mechanical and biological valves for aortic valve replacement is still controversial.</p>
        </sec>
        <sec>
          <title>Objective</title>
          <p>To compare outcomes of aortic valve replacement with bioprosthesis and mechanical prosthesis.</p>
        </sec>
        <sec>
          <title>Methods</title>
          <p>This was an observational, historical cohort study with review of medical records. A total of 202 patients who underwent heart valve replacement surgery between 2004 and 2008 were selected, with a mean follow-up of 10 years. The level of significance set at 5%.</p>
        </sec>
        <sec>
          <title>Results</title>
          <p>Mean age of patients was approximately 50 years; most patients were male (70%). Overall mortality- and reoperation-free survival was significantly higher in patients with mechanical prosthesis (HR=0.33; 95%CI=0.13-0.79; p=0.013). No difference was found in late mortality between the two groups. On the other hand, the risk of reoperation was significantly higher in patients with bioprosthesis than mechanical prosthesis (HR=0.062; 95%CI=0.008-0.457; p=0.006). The risk of composite adverse events &#8211; stroke, bleeding, endocarditis, thrombosis and paravalvular leak &#8211; was similar between the groups (HR=1.20; 95%CI= 0.74-1.93; p=0.44). The risk of bleeding was significantly higher in patients with mechanical prosthesis (HR=3.65; 95%CI= 1.43-9.29; p = 0.0064), although no case of fatal bleeding was reported.</p>
        </sec>
        <sec>
          <title>Conclusion</title>
          <p>No difference in 10-year mortality was found between the groups. The risk of reoperation significantly increases with the use of bioprosthesis, especially for patients younger than 30 years. Patients with mechanical prosthesis are at increased risk of nonfatal bleeding.</p>
        </sec>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>Aortic Valve</kwd>
        <kwd>Bioprosthesis/trends</kwd>
        <kwd>Heart Valve Prosthesis Implantation/complications</kwd>
        <kwd>Heart Valve Prosthesis</kwd>
        <kwd>Rheumatic Fever</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <sec sec-type="intro">
        <title>Introduction</title>
        <p>Surgical aortic-valve replacement has been performed since the 1950s.<sup><xref rid="B1" ref-type="bibr">1</xref></sup>Since then, technical advances in prosthetic manufacturing and optimization in surgical procedure have reduced the risk of complications related to the procedure, and significantly improved long-term prognosis.<sup><xref rid="B1" ref-type="bibr">1</xref></sup></p>
        <p>Despite constant improvement and refinement of the prostheses, the decision between mechanical and biological valves for aortic valve replacement is still controversial. The main disadvantage of biological prostheses is deterioration of the leaflets; in contrast, compared with mechanical prostheses, bioprostheses are less thrombogenic, requiring lower time of anticoagulation, and do not produce any sounds. On the other hand, mechanical prostheses require long anticoagulation therapy, significant lifestyle changes and impose a higher risk of thromboembolic and hemorrhagic events in long term.<sup><xref rid="B2" ref-type="bibr">2</xref></sup></p>
        <p>There are few studies in Brazil comparing the performance of biological and mechanical prostheses and describing the influence of epidemiological parameters on 10-year outcomes.</p>
        <p>In Brazil, rheumatic fever is the main cause of valvular heart disease and, compared with developed countries, patients undergo surgical intervention at a younger age.<sup><xref rid="B3" ref-type="bibr">3</xref></sup>In addition, many patients with valvular heart disease come from low-income backgrounds and hence likely to have a poor anticoagulation control.</p>
        <p>The aim of the present study was to assess mortality, reoperation, and adverse events in patients undergoing aortic valve replacement surgery with mechanical or biologic valve prosthesis in a S&#227;o Paulo State public tertiary hospital.</p>
      </sec>
      <sec sec-type="methods">
        <title>Methods</title>
        <p>This was an observational, historical cohort study with review of medical records.</p>
        <sec>
          <title>Study sample</title>
          <p>The study sample was composed of patients aged between 18 and 65 years, who underwent an aortic valve replacement surgery with mechanical or biologic valve prosthesis between January 01, 2004 and December 31, 2008, with a mean follow-up of 10 years. All mechanical prostheses were two-leaflet prosthetic heart valves, and all bioprostheses were national prostheses available in the Brazilian national unified health system.</p>
          <p>The combined primary outcome was reoperation-free survival and late all-cause mortality (30 days after surgery). Secondary outcome: event-free survival time, composed of stroke, bleeding, endocarditis, thrombosis and paravalvular leak.</p>
          <p>In addition, age, sex, aortic valve dysfunction, heart rhythm, use of anticoagulation, and echocardiographic data (degree of pulmonary hypertension, left ventricular ejection fraction, and ventricular diameters) were also evaluated. The choice of prosthesis was left to the discretion of the treating cardiologist, considering patient&#8217;s age, clinical features, socioeconomic status, and possible anticoagulation.</p>
        </sec>
        <sec>
          <title>Ethical aspects</title>
          <p>Clinical and surgical aspects during the study period were collected from patients&#8217; medical records. Regarding privacy and confidentiality, participants&#8217; anonymity was ensured, and information gathered during the study was used only for the study purposes. The study was approved by ethics committee of Dante Pazzanese Institute of Cardiology (registration number 4864/2018).</p>
        </sec>
        <sec>
          <title>Definitions</title>
          <p>Definitions used in this study followed the European Association of Percutaneous Cardiovascular Interventions (EAPCI), the European Society of Cardiology (ESC), and the European Association for Cardio-Thoracic Surgery (EACTS) guidelines, and the 2017 Update of the Brazilian Guidelines on Valvular Heart Disease.</p>
        </sec>
        <sec>
          <title>Statistical analysis</title>
          <p>Quantitative variables were described as mean and standard deviation, and qualitative variables as absolute and relative frequencies.</p>
          <p>For group comparisons, the Student&#8217;s t-test for independent samples was used for quantitative variables, and the Fisher&#8217;s exact test for qualitative variables (rates and proportions). The Kaplan-Meier curve was used for analysis of survival time, reoperation-free survival time, and event-free survival time (stroke, bleeding, endocarditis, thrombosis and paravalvular leak), and the Log-rank test used for comparisons of the curves between the groups.</p>
          <p>Analysis of the outcomes was made using the cox proportional hazards model. A multiple regression analysis of variables was not performed, since the stepwise selection model resulted in a simple Cox proportional hazards regression model itself. For measurement of effect, the instantaneous incidence rate (hazard ratio) and respective 95% confidence interval (95%CI) was calculated. Significance level was set at 5%. Data were analyzed with the support of the statistical programming environment R (R Core Team, 2019).</p>
          <p>Differences in early mortality between the groups were compared using Fisher&#8217;s exact test, considering the number of eligible patients and six patients were excluded for death within 30 days of surgical procedure. These six patients were not considered in the analysis. The analysis was robust to this censoring assumption, since the p-value remained non-significant, even when all patients excluded for loss to follow-up (absent for more than 30 days), were considered as &#8216;early death&#8217; or &#8216;no early death&#8217;.</p>
          <p>For analysis of reoperation rate across age subgroups (18-29 years / 30-49 years/ &#8805; 50 years), the Bonferroni test was used, with an adjusted p-value of 0.05/3 = 0.016666.</p>
        </sec>
      </sec>
      <sec sec-type="results">
        <title>Results</title>
        <sec>
          <title>Study sample</title>
          <p>A total of 221 patients who underwent aortic valve replacement alone were studied. Thirty-day postoperative mortality was 2.7% (n=6). Thirteen patients (5.8%) were lost to follow-up. Then, 202 patients were considered eligible; 132 (65.3%) with bioprosthesis &#8211; 126 of them (95.5%) with a porcine bioprosthesis and six (4.5%) with a bovine pericardium bioprosthesis &#8211; and 70 (34.7%) with a mechanical prosthesis as described in <xref rid="f01001" ref-type="fig">Figure 1</xref> .</p>
          <p>
            <fig id="f01001">
              <label>Figure 1</label>
              <caption>
                <title>&#8211; Flowchart of patient selection</title>
              </caption>
              <graphic xlink:href="1678-4170-abc-117-01-0028-00135-gf01-en.tif"/></fig>
          </p>
          <p>Mean follow-up was 9.3 &#177; 3.8 years, median of 10.45 years; 74% of patients were followed for more than eight years. The maximum duration of follow-up was 14.25 years for bioprostheses and 14.34 years for mechanical prostheses.</p>
          <p>Baseline characteristics were similar between patients with bioprosthesis and mechanical valve prosthesis ( <xref rid="t1001" ref-type="table">Table 1</xref> ). As expected, the use of anticoagulation was more prevalent in the group of patients who underwent aortic valve replacement with a mechanical prosthesis (p&lt;0.001). No difference between the groups was found in any other variables - age, sex, cause of valve dysfunction, heart rhythm or echocardiographic parameters (PASP: pulmonary artery systolic pressure; PH: pulmonary hypertension; LFEF: left ventricular ejection fraction; LVESD: left ventricular end-systolic diameter; LVEDD: LV end-diastolic diameter).</p>
          <p>
            <table-wrap id="t1001">
              <label>Table 1</label>
              <caption>
                <title>&#8211; Characteristics of the study groups</title>
              </caption>
              <table frame="hsides" rules="groups">
                <colgroup>
                  <col/>
                  <col/>
                  <col/>
                  <col/>
                </colgroup>
                <thead>
                  <tr>
                    <th align="left">Variable</th>
                    <th colspan="2">Study groups</th>
                    <th>p-value*</th>
                  </tr>
                  <tr>
                    <th align="left" style="font-weight:normal"> </th>
                    <th>Bioprosthesis</th>
                    <th>Mechanical prosthesis</th>
                    <th align="left" style="font-weight:normal"> </th>
                  </tr>
                  <tr>
                    <th align="left" style="font-weight:normal"> </th>
                    <th>(N= 132)</th>
                    <th>(N= 70)</th>
                    <th align="left" style="font-weight:normal"> </th>
                  </tr>
                </thead>
                <tbody>
                  <tr>
                    <td>
                      <bold>Age &#177; SD</bold>
                    </td>
                    <td align="center">50.78&#177;11.67</td>
                    <td align="center">47.67&#177;14.09</td>
                    <td align="center">0.116</td>
                  </tr>
                  <tr>
                    <td>
                      <bold>Sex - n (%)</bold>
                    </td>
                    <td> </td>
                    <td> </td>
                    <td align="center">0.504</td>
                  </tr>
                  <tr>
                    <td> Male</td>
                    <td align="center">75.8%</td>
                    <td align="center">71.4%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td> Female</td>
                    <td align="center">24.2%</td>
                    <td align="center">28.6%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td>
                      <bold>Etiology - n (%)</bold>
                    </td>
                    <td> </td>
                    <td> </td>
                    <td align="center">0.357</td>
                  </tr>
                  <tr>
                    <td> Degenerative</td>
                    <td align="center">62.1%</td>
                    <td align="center">57.1%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td> Rheumatic</td>
                    <td align="center">21.9%</td>
                    <td align="center">22.9%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td> Aortic dilatation</td>
                    <td align="center">12.1%</td>
                    <td align="center">10%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td> Bicuspid</td>
                    <td align="center">3.9%</td>
                    <td align="center">10%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td>
                      <bold>ECG rhythm- n (%)</bold>
                    </td>
                    <td> </td>
                    <td> </td>
                    <td align="center">0.568</td>
                  </tr>
                  <tr>
                    <td> Sinus</td>
                    <td align="center">80.3%</td>
                    <td align="center">84.3%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td> AF/Atrial flutter</td>
                    <td align="center">19.7%</td>
                    <td align="center">15.7%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td>
                      <bold>Anticoagulant therapy &#8211; (Marevan) n (%)</bold>
                    </td>
                    <td> </td>
                    <td> </td>
                    <td align="center">&lt; 0.001</td>
                  </tr>
                  <tr>
                    <td> Yes</td>
                    <td align="center">12.1%</td>
                    <td align="center">97.1%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td> No</td>
                    <td align="center">87.9%</td>
                    <td align="center">2.9%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td colspan="4">
                      <bold>Preoperative ECHO</bold>
                    </td>
                  </tr>
                  <tr>
                    <td> PASP &#177; SD</td>
                    <td> </td>
                    <td> </td>
                    <td align="center">0.551</td>
                  </tr>
                  <tr>
                    <td> Without PH</td>
                    <td align="center">78%</td>
                    <td align="center">82.6%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td> Mild PH</td>
                    <td align="center">16.7%</td>
                    <td align="center">11.6%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td> Moderate PH</td>
                    <td align="center">3.8%</td>
                    <td align="center">5.8%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td> Severe PH</td>
                    <td align="center">1.5%</td>
                    <td align="center">0%</td>
                    <td> </td>
                  </tr>
                  <tr>
                    <td> LVEF &#177; SD</td>
                    <td align="center">58.51&#177;12.71</td>
                    <td align="center">61.68&#177;10.9</td>
                    <td align="center">0.067</td>
                  </tr>
                  <tr>
                    <td> LVESD &#177; SD</td>
                    <td align="center">41.01&#177;11.79</td>
                    <td align="center">40.06&#177;11.28</td>
                    <td align="center">0.547</td>
                  </tr>
                  <tr>
                    <td> LVEDD &#177; SD</td>
                    <td align="center">60.92&#177;11.68</td>
                    <td align="center">60.74&#177;12.7</td>
                    <td align="center">0.923</td>
                  </tr>
                </tbody>
              </table>
              <table-wrap-foot>
                <fn id="TFN1001">
                  <p>
                    <italic>* p&lt;0.05 SD: standard deviation; ECG: electrocardiogram; AF: atrial fibrillation; PASP: pulmonary artery systolic pressure; PH: pulmonary hypertension; LFEF: left ventricular ejection fraction; LVESD: left ventricular end-systolic diameter; LVEDD: left ventricular end-diastolic diameter; ECHO: echocardiogram.</italic>
                  </p>
                </fn>
              </table-wrap-foot>
            </table-wrap>
          </p>
          <p>No difference in early mortality rate was seen between the two types of valve prostheses (1.3% mechanical prosthesis versus 3.5% biological prosthesis; p = 0.666). Six of 221 (2.7%) patients died less than 30 days after surgery and were excluded from the analysis since the aim of this study was to compare the performance of the prostheses in long term.</p>
        </sec>
        <sec>
          <title>Survival and reoperation data</title>
          <p>All-cause survival rate was significantly higher in patients with bioprosthesis compared with those with mechanical prosthesis (HR= 0.33; 95%CI 0.13-0.79; p= 0.013) ( <xref rid="f02001" ref-type="fig">Figure 2</xref> ).</p>
          <p>
            <fig id="f02001">
              <label>Figure 2</label>
              <caption>
                <title>&#8211; Kaplan-Meier curve for primary outcome-free survival (death or reoperation).</title>
              </caption>
              <graphic xlink:href="1678-4170-abc-117-01-0028-00135-gf02-en.tif"/></fig>
          </p>
          <p>In a ten-year period, eight patients with bioprosthesis and five patients with mechanical prosthesis died, corresponding to an adjusted percentage of 6.1% and 7.9%, respectively, respectively (p=0.68).</p>
          <p>On the other hand, the analysis of reoperation alone revealed a significant difference in favor of mechanical prosthesis (HR=0.062; 95%CI = 0.008-0.457; p=0.006). In ten years, 19 (21.24%) patients with bioprosthesis were reoperated, whereas no event was recorded in the mechanical prosthesis group.</p>
          <p>Reoperation was analyzed according to subgroups of age &#8211; &lt;30 years, between 30 and 49 years and &#8805;50 years. Probability of reoperation was higher in patients younger than 30 years compared with those aged 30-49 years (HR= 6.69; 95%CI=1.88-23.8; p=0.003) and patients aged &#8805; 50 years (HR= 3.51; CI95% = 1.37-9.03; p=0.008). No difference was observed between patients &#8805;50 years and those aged 30-49 years (HR= 0.50; 95%CI= 0.16-1.50; p=0.219) ( <xref rid="f03001" ref-type="fig">Figure 3</xref> ).</p>
          <p>
            <fig id="f03001">
              <label>Figure 3</label>
              <caption>
                <title>&#8211; Kaplan-Meier curve for reoperation-free survival by age groups (18-29 years, 30 - 49 years and &#8805; 50 years.</title>
              </caption>
              <graphic xlink:href="1678-4170-abc-117-01-0028-00135-gf03-en.tif"/></fig>
          </p>
        </sec>
        <sec>
          <title>Adverse events</title>
          <p>Secondary outcome composed of stroke, bleeding, endocarditis, thrombosis and paravalvular leak was similar between the two groups (HR=1.20; 95%CI= 0.74-1.93; p=0.44), as illustrated in <xref rid="f04001" ref-type="fig">Figure 4</xref> .</p>
          <p>
            <fig id="f04001">
              <label>Figure 4</label>
              <caption>
                <title>&#8211; Kaplan-Meier curve for secondary outcome-free survival (stroke, bleeding, endocarditis, thrombosis and paravalvular leak).</title>
              </caption>
              <graphic xlink:href="1678-4170-abc-117-01-0028-00135-gf04-en.tif"/></fig>
          </p>
          <p>Results of the analysis of secondary outcome by the hazard ratio was represented by a forest plot ( <xref rid="f05001" ref-type="fig">Figure 5</xref> ).</p>
          <p>
            <fig id="f05001">
              <label>Figure 5</label>
              <caption>
                <title>&#8211; Forest Plot of adverse effects by type of heart valve prosthesis (mechanical or biological).</title>
              </caption>
              <graphic xlink:href="1678-4170-abc-117-01-0028-00135-gf05-en.tif"/></fig>
          </p>
          <p>The risk of bleeding was significantly higher in patients with mechanical prosthesis than patients with bioprosthesis (HR=3.65; 95%CI = 1.43-9.29; p=0.0064). After adjustment for censored data, the 10-year risk of bleeding was 5.38% in patients with bioprosthesis, and 20.97% in patients with mechanical prosthesis.</p>
          <p>The rate of stroke in 10 years was 14.10% for the group of biological prosthesis and 11.56% for the group of mechanical prosthesis (p=0.47). The risk of paravalvular leak was similar between patients with biological and mechanical heart valve prostheses (HR=0.71; 95%CI= 0.22-2.24; p=0.56). The 10-year rate of paravalvular leak, adjusted for censored data, was 6.53% for patients with bioprosthesis and 3.38% for patients with mechanical valve.</p>
          <p>The risk of endocarditis was similar between the groups (HR=1.30; 95%CI= 0.46-3.66; p=0.61). The 10-year rate of endocarditis, adjusted for censored data, was 6.12% for patients with bioprosthesis and 1.57% for patients with mechanical valve prosthesis.</p>
          <p>The risk of thrombosis was similar between the groups (=0.1). The 10-year rate of thrombosis, adjusted for censored data, was 5.06% for patients with bioprosthesis and no event was recorded in the group with mechanical valve prosthesis.</p>
          <p>The observed rate of paravalvular leak identified in the first echocardiography was 3.78% (n=5) for patients with biological valve and no event was recorded in the group with mechanical valve. A more detailed statistical analysis was not possible since no event was recorded in the group of mechanical valve prosthesis.</p>
        </sec>
      </sec>
      <sec sec-type="discussion">
        <title>Discussion</title>
        <p>More than 30 years have passed since the introduction of modern heart valve prostheses, and the choice between mechanical and biological valves remains controversial. There are few randomized, controlled studies, involving a large number of patients, to guide the selection of the best prosthesis. The level of evidence in most guidelines is low (level C), and the selection of prosthesis has depended on limited data, clinical experience, and common sense. We hope that this study will add knowledge about the performance of mechanical and biological heart valve prostheses in this specific group of patients.</p>
        <p>In the present study, we aimed to assess the outcomes of aortic valve replacement with a biological or a mechanical prosthesis in a group of patients who use public healthcare services in Brazil. Degenerative disease was the main cause of valvulopathy, followed by rheumatic disease, which accounted for nearly 22% of the cases. This predominance of degenerative disease is similar to that in developed countries; however, the relatively modest percentage of rheumatic disease may be explained by the fact that we included patients aged at least 18 years and that this is a study on isolated aortic valve disease.<sup><xref rid="B4" ref-type="bibr">4</xref></sup></p>
        <p>It is of note that approximately 80% of total patients were in sinus rhythm; although 19.7% of patients with bioprosthesis had atrial fibrillation, only 12.1% were receiving anticoagulation treatment. Despite recommendations and the risk of thrombosis, two patients with mechanical valve prosthesis were using anticoagulants; one had stroke and the other died. These findings reflect the difficulty of performing anticoagulation in less privileged groups. No statistically significant difference was found in the preoperative echocardiographic parameters between patients with biological and mechanical valve prostheses. Most patients had preserved left ventricular function and did not have severe pulmonary hypertension.</p>
        <p>Mean age of patients was 50 years. The risk of reoperation was significantly higher in patients with bioprosthesis, mainly in those younger than 30 years. The distance between the curves becomes larger in the fourth year of valve prosthesis implantation, more evidently after eight years of surgery, when 50% of patients younger than 30 years already had indication for reoperation. In a mean of 10 years, only one patient with mechanical prosthesis required reoperation. In accordance with these findings, Hammermeister et al.<sup><xref rid="B5" ref-type="bibr">5</xref></sup>reported a greater number of interventions in patients with a bioprosthesis compared with a mechanical prosthesis for aortic valve replacement (29% <italic>versus</italic> 10%; p = 0.004).<sup><xref rid="B5" ref-type="bibr">5</xref></sup>It is worth mentioning that reoperation rates do not accurately reflect the likelihood of structural valve degeneration, since some patients with significant structural deterioration are not candidates for reoperation due to high surgical risk.</p>
        <p>Late mortality was similar between the two groups, with similar adjusted rates &#8211; 6.11% in patients with bioprosthesis and 7.93% in patients with mechanical prosthesis (p=0.68). However, more recent studies have reported mixed results, with a trend of lower mortality rates in patients with mechanical prosthesis, younger than 55 years.<sup><xref rid="B6" ref-type="bibr">6</xref></sup></p>
        <p>Bleeding occurred in patients of both groups; however, although the use of anticoagulation therapy was more frequent in patients with mechanical prosthesis than bioprosthesis (97.1% vs. 12,1%), bleeding was more frequent in the former group (p=0.0064). No case of fatal bleeding or hemorrhagic stroke was reported. Likewise, in the Veterans Affairs Cooperative Study, 575 patients were randomly assigned to receive either a mechanical valve or a biological one. The risk of bleeding in 11 years was significantly higher in patients with mechanical valves (42% <italic>versus</italic> 26%).<sup><xref rid="B7" ref-type="bibr">7</xref></sup></p>
        <p>In our cohort, there was no significant difference in the risk of endocarditis between biological and mechanical valve prostheses. The frequency of infections is usually similar between patients with the two types of valve prosthesis during the first postoperative year. In long-term follow-up, the incidence rates of endocarditis in patients with bioprosthesis is comparable to or slightly higher than mechanical prosthesis, although available data are scarce.<sup><xref rid="B8" ref-type="bibr">8</xref></sup></p>
        <p>The literature has shown a higher incidence of valve prosthesis thrombosis among patients with mechanical than biological prosthesis and highlighted the need for continuous anticoagulation in these patients.<sup><xref rid="B9" ref-type="bibr">9</xref></sup>This is in accordance with our results, as no statistically significant difference was found in the rate of thrombosis, with an adjusted rate of 5.06% for biological prosthesis and no case recorded for mechanical prosthesis. This may be explained by the fact that our patients were treated in a center specialized in anticoagulation. Chiquette et al.<sup><xref rid="B10" ref-type="bibr">10</xref></sup>compared treatment with usual medical care and treatment at an anticoagulation center, and reported lower rates of thromboembolic events (minor, major and fatal events).<sup><xref rid="B10" ref-type="bibr">10</xref></sup></p>
        <p>There was no difference in the risk of ischemic stroke between the two groups (adjusted rate of 14.1% for the biological prosthesis <italic>versu</italic> s 11.5% for mechanical prosthesis at 10 years; p = 0.47). Data in the literature suggested that the risk of thromboembolic complications is usually similar or lower in patients with biological prosthesis compared with patients with mechanical prosthesis and anticoagulation therapy. In an observational study, the cumulative risk of stroke in patients aged between 45 and 54 years undergoing aortic valve replacement was significantly lower (approximately 10% versus 16% at 15 years; HR = 0.64; 95%CI 0.46-0.86; p &lt; 0.05).<sup><xref rid="B6" ref-type="bibr">6</xref></sup>The increased risk of stroke in our population may be explained by the high prevalence of comorbidities associated, absence of anticoagulation therapy among patients with atrial fibrillation, and lack of prothrombin time control of patients.</p>
        <p>In addition, no difference was found in the risk of paravalvular leak between the aortic valves (biological and mechanical). The 10-year rate of paravalvular leak, adjusted for the censored data was 3.38% for the patients with mechanical prosthesis, which is corroborated by the literature, which reports an incidence of 2-10% in patients with aortic valve prostheses. As an example, studies using transesophageal echocardiography after heart valve replacement surgery, the incidence of paravalvular leak varied from 3% to 6%, with a statistical trend for a higher prevalence in patients with mechanical valve prostheses.<sup><xref rid="B11" ref-type="bibr">11</xref></sup></p>
        <p>In our study, prosthesis-patient mismatch (PPM) was present in 3.76% of patients with bioprosthesis and in no patient with mechanical prosthesis and, for this reason, a simple descriptive analysis was performed. Data in the literature have reported higher incidence of PPM, ranging from 20% to 70%.<sup><xref rid="B12" ref-type="bibr">12</xref></sup>According to the meta-analysis by the European Heart Journal of 34 studies and a total of 27,186 patients, the presence of PPM was associated with a reduced long term survival (HR = 1.34, 95% CI = 1.18-1.51).<sup><xref rid="B13" ref-type="bibr">13</xref></sup>IN the comparison between biological and mechanical prostheses, it is probable that bioprosthesis is more prone to PPM, since the effective orifice area of mechanical prostheses is relatively larger due to the area occupied by the suture ring. In patients with a small aortic annulus, the effective orifice area is crucial to improve the hemodynamic performance of the prosthesis, and thereby prevent the occurrence of PPM. In some cases, patients with a small aortic annulus may benefit from a mechanical posthesis.<sup><xref rid="B1" ref-type="bibr">1</xref></sup></p>
        <p>In the present study, the mean waiting time for surgery was 202 days, with a wide range of distribution, which may be explained by the different indications for surgery and different characteristics of patients.</p>
        <sec>
          <title>Study limitations</title>
          <p>One limitation of the present study was its nonrandomized design, which limits the external validity of the results. However, the findings may serve as a basis for further analytical and prospective studies to obtain more consistent conclusions. Other caveats include the fact that this was a single center study, the insufficient sample size for rare events, and loss to follow-up.</p>
          <p>In addition, we did not assess reoperation-related mortality, which may have underestimated mortality rates in the bioprosthesis group. Also, prothrombin time data were not evaluated, which makes it difficult to understand the high incidence of ischemic stroke in both groups.</p>
        </sec>
      </sec>
      <sec sec-type="conclusions">
        <title>Conclusion</title>
        <p>The probability of overall mortality- and reoperation-free survival in patients with a mean age of 50 years undergoing heart valve replacement surgery in a public tertiary hospital in Sao Paulo State was significantly higher in patients with mechanical valve prosthesis at the expense of a greater durability of this type of prosthesis. No difference was seen in 10-year mortality or in combined adverse events between the groups. A greater need for reoperation was found in patients with bioprosthesis younger than 30 years old. Although no case of fatal bleeding was reported, bleeding was more frequent in patients with mechanical prosthesis than bioprosthesis.</p>
      </sec>
    </body>
    <back>
      <ack>
        <title>Acknowledgment</title>
        <p>Special thanks to the valvulopathy sector of the Instituto Dante Pazzanese de Cardiologia for providing medical service to the community and contributing to the development of research in this area. Thanks to the management of the hospital and the sector medical teams for working together on behalf of the patient, collaborating with the performance of complementary exams and joint analysis of the clinical case.</p>
        <p>Special thanks to patients who place their trust in the hospital&#8217;s multidisciplinary team to care for their health and enable continuous improvement.</p>
      </ack>
      <fn-group>
        <fn fn-type="other">
          <p>Study Association</p>
          <p>This article is part of the thesis of master submitted by Larissa Ventura Ribeiro Bruscky, from Universidade de S&#227;o Paulo.</p>
        </fn>
        <fn fn-type="supported-by" id="fn4001">
          <p><bold>Sources of Funding</bold>:  There were no external funding sources for this study.</p>
        </fn>
      </fn-group>
    </back>
  </sub-article>
</article>
