<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="1.1" specific-use="sps-1.9" xml:lang="pt">
  <front>
    <journal-meta>
      <journal-id journal-id-type="nlm-ta">Arq Bras Cardiol</journal-id>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">TW9Vdds9r3Hrf3gWVtwcyZt</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2020000600764</article-id>
      <article-id pub-id-type="publisher-id">abc.20190255</article-id>
      <article-id pub-id-type="doi">10.36660/abc.20190255</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigo Original</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Evid&#234;ncias de Validade da Vers&#227;o Brasileira da <italic>Florida Shock Anxiety Scale</italic> para Portadores de Cardioversor-Desfibrilador Implant&#225;vel</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-5723-8285</contrib-id>
          <name>
            <surname>Silva</surname>
            <given-names>Katia Regina</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Costa</surname>
            <given-names>Roberto</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Melo</surname>
            <given-names>Giovanna Regina Garcia de Oliveira</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-3746-3266</contrib-id>
          <name>
            <surname>Rebustini</surname>
            <given-names>Fl&#225;vio</given-names>
          </name>
          <xref ref-type="aff" rid="aff2">
            <sup>2</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0003-1283-9746</contrib-id>
          <name>
            <surname>Benedetto</surname>
            <given-names>Marcos Sidney</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-0181-8651</contrib-id>
          <name>
            <surname>Nagumo</surname>
            <given-names>Marcia Mitie</given-names>
          </name>
          <xref ref-type="aff" rid="aff1">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Sears</surname>
            <given-names>Samuel F.</given-names>
          </name>
          <xref ref-type="aff" rid="aff3">
            <sup>3</sup>
          </xref>
        </contrib>
      </contrib-group>
      <aff id="aff1">
        <label>1</label>
        <institution content-type="orgdiv2">Instituto do Cora&#231;&#227;o</institution>
        <institution content-type="orgdiv1">Faculdade de Medicina</institution>
        <institution content-type="orgname">Universidade de S&#227;o Paulo</institution>
        <addr-line>
          <named-content content-type="city">S&#227;o Paulo</named-content>
          <named-content content-type="state">SP</named-content>
        </addr-line>
        <country country="BR">Brasil</country>
        <institution content-type="original">Instituto do Cora&#231;&#227;o (InCor) - Faculdade de Medicina da Universidade de S&#227;o Paulo,S&#227;o Paulo, SP &#8211; Brasil</institution>
      </aff>
      <aff id="aff2">
        <label>2</label>
        <institution content-type="orgname">Universidade de S&#227;o Paulo</institution>
        <institution content-type="orgdiv1">Escola de Artes, Ci&#234;ncias e Humanidades</institution>
        <addr-line>
          <named-content content-type="city">S&#227;o Paulo</named-content>
          <named-content content-type="state">SP</named-content>
        </addr-line>
        <country country="BR">Brasil</country>
        <institution content-type="original">Universidade de S&#227;o Paulo - Escola de Artes, Ci&#234;ncias e Humanidades, S&#227;o Paulo, SP - Brasil</institution>
      </aff>
      <aff id="aff3">
        <label>3</label>
        <institution content-type="orgname">East Carolina University</institution>
        <institution content-type="orgdiv1">Department of Psychology and Cardiovascular Sciences Greenville</institution>
        <addr-line>
          <named-content content-type="city">North Carolina</named-content>
        </addr-line>
        <country country="US">USA</country>
        <institution content-type="original">East Carolina University - Department of Psychology and Cardiovascular Sciences Greenville, North Carolina &#8211; USA</institution>
      </aff>
      <author-notes>
        <corresp id="c01"> Correspond&#234;ncia: Katia Regina Regina Silva &#8226; Instituto do Cora&#231;&#227;o do Hospital das Cl&#237;nicas da Faculdade de Medicina da Universidade de S&#227;o Paulo - Unidade de Estimula&#231;&#227;o El&#233;trica e Marcapasso - Dr. En&#233;as de Carvalho Aguiar, 44. CEP 05403-900, S&#227;o Paulo, SP &#8211; Brasil E-mail: <email>katia.regina@incor.usp.br</email>
				</corresp>
        <fn fn-type="con">
          <p>Contribui&#231;&#227;o dos autores</p>
          <p>Concep&#231;&#227;o e desenho da pesquisa: Silva KR, Costa R; Obten&#231;&#227;o de dados: Melo GRGO, Benedetto MS; An&#225;lise e interpreta&#231;&#227;o dos dados: Silva KR, Rebustini F; An&#225;lise estat&#237;stica: Rebustini F; Obten&#231;&#227;o de financiamento e reda&#231;&#227;o do manuscrito: Silva KR; Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do intelectual importante: Costa R, Rebustini F, Nagumo MM, Sears SF.</p>
        </fn>
        <fn fn-type="conflict">
          <p>Potencial conflito de interesses</p>
          <p>Declaro n&#227;o haver conflito de interesses pertinentes.</p>
        </fn>
      </author-notes>
      <pub-date date-type="pub" publication-format="electronic">
        <day>01</day>
        <month>06</month>
        <year>2020</year>
      </pub-date>
      <pub-date date-type="collection" publication-format="electronic">
        <month>05</month>
        <year>2020</year>
      </pub-date>
      <volume>114</volume>
      <issue>5</issue>
      <fpage>764</fpage>
      <lpage>772</lpage>
      <history>
        <date date-type="received">
          <day>19</day>
          <month>12</month>
          <year>2018</year>
        </date>
        <date date-type="rev-recd">
          <day>04</day>
          <month>06</month>
          <year>2019</year>
        </date>
        <date date-type="accepted">
          <day>23</day>
          <month>06</month>
          <year>2019</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/" xml:lang="en">
          <license-p> This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. </license-p>
        </license>
      </permissions>
      <abstract>
        <title>Resumo</title>
        <sec>
          <title>Fundamento</title>
          <p> A despeito da comprovada efetividade do cardioversor-desfibrilador implant&#225;vel (CDI), as terapias de choque deflagradas pelo dispositivo podem causar n&#237;veis elevados de ansiedade e depress&#227;o, provocando efeitos delet&#233;rios na qualidade de vida.</p>
        </sec>
        <sec>
          <title>Objetivo</title>
          <p> Realizar a tradu&#231;&#227;o, adapta&#231;&#227;o transcultural e valida&#231;&#227;o do instrumento <italic>Florida Shock Anxiety Scale</italic> (FSAS) para a l&#237;ngua portuguesa falada no Brasil.</p>
        </sec>
        <sec>
          <title>M&#233;todos</title>
          <p> Nesse estudo psicom&#233;trico, a validade de construto foi realizada pela an&#225;lise fatorial explorat&#243;ria (AFE) e confirmat&#243;ria (AFC) e pela Teoria de Resposta ao Item. Os &#237;ndices de ajustamento da AFC foram: Robust Mean-Scaled Chi Square/df NNFI, CFI (Comparative Fit Index), GFI (Goodness Fit Index), AGFI (Adjusted Goodness Fit Index), RMSEA (Root Mean Square Error of Approximation) e RMSR (Root Mean Square of Residuals). A confiabilidade foi verificada pelo Alfa de Cronbach, &#212;mega de McDonald e Greatest Lower Bound. As an&#225;lises foram realizadas no SPSS 23.0 e Factor 10.8.01, com n&#237;vel de signific&#226;ncia de 5%.</p>
        </sec>
        <sec>
          <title>Resultados</title>
          <p> A vers&#227;o final em portugu&#234;s do FSAS foi administrada em 151 portadores de CDI, com idade m&#233;dia de 55,7 &#177; 14,1 anos e predom&#237;nio do sexo masculino. A an&#225;lise paralela indicou que o FSAS &#233; unidimensional, com vari&#226;ncia explicada de 64,4%. As correla&#231;&#245;es variaram de 0,31 a 0,77; as cargas fatoriais de 0,67 a 0,86 e as comunalidades de 0,46 a 0,74. Os &#237;ndices de ajustamento da AFC estabeleceram-se acima dos limites de qualidade. Encontramos evid&#234;ncias satisfat&#243;rias de confiabilidade da escala FSAS.</p>
        </sec>
        <sec>
          <title>Conclus&#227;o</title>
          <p> O instrumento FSAS-Br apresentou evid&#234;ncias consistentes de validade e confiabilidade, podendo, portanto, ser utilizado em portadores de CDI do Brasil. (Arq Bras Cardiol. 2020; 114(5):764-772)</p>
        </sec>
      </abstract>
      <kwd-group xml:lang="pt">
        <kwd>Desfibrilador implant&#225;vel</kwd>
        <kwd>Terapias de choque</kwd>
        <kwd>Arritmias</kwd>
        <kwd>Ansiedade</kwd>
        <kwd>Qualidade de vida</kwd>
        <kwd>Validade</kwd>
        <kwd>Confiabilidade</kwd>
        <kwd>Psicometria</kwd>
      </kwd-group>
      <funding-group>
        <award-group>
          <funding-source>FAPESP</funding-source>
          <award-id>2016/02104-6</award-id>
        </award-group>
        <funding-statement>Fontes de financiamento. O presente estudo foi financiado pela FAPESP, na modalidade Aux&#237;lio &#224; Pesquisa (Processo 2016/02104-6).</funding-statement>
      </funding-group>
      <counts>
        <fig-count count="2"/>
        <table-count count="8"/>
        <equation-count count="0"/>
        <ref-count count="33"/>
        <page-count count="9"/>
      </counts>
    </article-meta>
  </front>
  <body>
    <sec sec-type="intro">
      <title>Introdu&#231;&#227;o</title>
      <p>Atualmente, n&#227;o existem d&#250;vidas quanto ao papel do cardioversor-desfibrilador implant&#225;vel (CDI) na preven&#231;&#227;o da morte s&#250;bita card&#237;aca, especialmente em pacientes com disfun&#231;&#227;o ventricular e doen&#231;as gen&#233;ticas arritmog&#234;nicas.<sup><xref ref-type="bibr" rid="B1">1</xref>-<xref ref-type="bibr" rid="B3">3</xref></sup>Por sua comprovada efic&#225;cia na identifica&#231;&#227;o e revers&#227;o de taquiarritmias ventriculares potencialmente letais, o n&#250;mero de implantes de CDI tem crescido exponencialmente no mundo inteiro, sendo realizados mais de 250.000 procedimentos por ano.<sup><xref ref-type="bibr" rid="B4">4</xref></sup></p>
      <p>A fun&#231;&#227;o primordial do CDI &#233; reverter arritmias ventriculares potencialmente fatais pela aplica&#231;&#227;o de terapias de baixa ou de alta energia. Terapias de baixa energia, conhecidas como estimula&#231;&#227;o antitaquicardia ou sobre-estimula&#231;&#227;o, n&#227;o provocam dor. Terapias de alta energia s&#227;o choques de at&#233; 40 joules que, apesar de causar grande desconforto, usualmente, s&#227;o aplicados ap&#243;s o paciente ter perdido a consci&#234;ncia, uma vez que s&#227;o disparados cerca de 15 segundos ap&#243;s o in&#237;cio da fibrila&#231;&#227;o ventricular ou de uma taquiarritmia ventricular r&#225;pida. Em situa&#231;&#245;es pouco desej&#225;veis, como &#233; o caso das arritmias resistentes &#224; sobre-estimula&#231;&#227;o ou nas tempestades el&#233;tricas, choques de alta energia podem ocorrer em pacientes acordados.<sup><xref ref-type="bibr" rid="B3">3</xref>,<xref ref-type="bibr" rid="B5">5</xref>,<xref ref-type="bibr" rid="B6">6</xref></sup></p>
      <p>Estima-se que a chance de portadores de CDI necessitar de um choque apropriado para preven&#231;&#227;o prim&#225;ria da morte s&#250;bita card&#237;aca varia de 2 a 15% ao ano.<sup><xref ref-type="bibr" rid="B5">5</xref>-<xref ref-type="bibr" rid="B8">8</xref></sup> Por outro lado, quando o CDI &#233; utilizado para preven&#231;&#227;o secund&#225;ria, a incid&#234;ncia de terapias de choque pode variar de 35 a 53%, no primeiro ano ap&#243;s o implante.<sup><xref ref-type="bibr" rid="B5">5</xref>-<xref ref-type="bibr" rid="B8">8</xref></sup> A despeito do elevado n&#237;vel de sofistica&#231;&#227;o tecnol&#243;gica dos CDIs, lamentavelmente, existe o risco de o paciente receber um choque inapropriado em decorr&#234;ncia da discrimina&#231;&#227;o err&#244;nea entre taquiarritmias supraventriculares e ventriculares. Nessas ocasi&#245;es, a sensa&#231;&#227;o relatada &#233; de uma experi&#234;ncia dolorosa e angustiante.<sup><xref ref-type="bibr" rid="B9">9</xref>-<xref ref-type="bibr" rid="B14">14</xref></sup></p>
      <p>Portadores de CDI convivem com a expectativa de que, a qualquer momento, o dispositivo ir&#225; aplicar terapias de choque para interromper arritmias ventriculares decorrentes de sua doen&#231;a card&#237;aca. Desse modo, apesar de reconhecerem os benef&#237;cios do tratamento, alguns pacientes podem apresentar quadros de ansiedade, depress&#227;o, dist&#250;rbios do humor, transtorno de estresse p&#243;s-traum&#225;tico, bem como medo do n&#227;o funcionamento do dispositivo em momentos cruciais.<sup><xref ref-type="bibr" rid="B9">9</xref>-<xref ref-type="bibr" rid="B14">14</xref></sup>Por outro lado, tem sido reportado que o implante do CDI pode conferir aos pacientes uma grande sensa&#231;&#227;o de seguran&#231;a, considerando-se a capacidade do dispositivo para interromper epis&#243;dios inesperados de taquiarritmias ventriculares potencialmente letais.<sup><xref ref-type="bibr" rid="B10">10</xref>-<xref ref-type="bibr" rid="B14">14</xref></sup></p>
      <p>Diante da preocupa&#231;&#227;o com os efeitos delet&#233;rios do CDI na adapta&#231;&#227;o psicossocial, foi desenvolvido um instrumento especificamente destinado &#224; avalia&#231;&#227;o do n&#237;vel de ansiedade relacionado &#224; presen&#231;a do CDI e aos choques aplicados pelo dispositivo, para uso na pr&#225;tica cl&#237;nica e no cen&#225;rio da pesquisa cient&#237;fica.<sup><xref ref-type="bibr" rid="B15">15</xref>,<xref ref-type="bibr" rid="B16">16</xref></sup> Em pouco tempo, o instrumento <italic>Florida Shock Anxiety Scale</italic> (FSAS) alcan&#231;ou grande aceita&#231;&#227;o internacional, tendo sido traduzido e validado em diferentes culturas (Holanda,<sup><xref ref-type="bibr" rid="B17">17</xref></sup> Dinamarca,<sup><xref ref-type="bibr" rid="B18">18</xref></sup> Pol&#244;nia,<sup><xref ref-type="bibr" rid="B19">19</xref></sup> China,<sup><xref ref-type="bibr" rid="B20">20</xref></sup> Noruega,<sup><xref ref-type="bibr" rid="B21">21</xref></sup> Turquia<sup><xref ref-type="bibr" rid="B22">22</xref></sup>), com resultados consistentes.</p>
    </sec>
    <sec>
      <title>Objetivos</title>
      <p>A finalidade do presente estudo foi avaliar as propriedades psicom&#233;tricas da vers&#227;o brasileira do instrumento FSAS para portadores de CDI.</p>
    </sec>
    <sec sec-type="methods">
      <title>M&#233;todos</title>
      <sec>
        <title>Desenho do estudo</title>
        <p>Trata-se de um estudo transversal com duas fases: (1) Processo de tradu&#231;&#227;o e adapta&#231;&#227;o transcultural do instrumento FSAS; (2) Valida&#231;&#227;o de construto do instrumento FSAS.</p>
      </sec>
      <sec>
        <title>Local do estudo e aspectos &#233;ticos</title>
        <p>Esse estudo foi realizado em um hospital cardiol&#243;gico de alta complexidade, tendo sido aprovado pelo Comit&#234; de &#201;tica em Pesquisa da Institui&#231;&#227;o. Todos os participantes assinaram o termo de consentimento livre e esclarecido (TCLE).</p>
      </sec>
      <sec>
        <title>Instrumento Florida Shock Anxiety Scale (FSAS)</title>
        <p>O instrumento FSAS foi desenvolvido em 2006 nos Estados Unidos para avaliar o n&#237;vel de ansiedade relacionado &#224; presen&#231;a do CDI e aos choques aplicados pelo dispositivo. O instrumento consiste em 10 itens, com cinco op&#231;&#245;es de resposta (&#8220;nunca&#8221;, &#8220;quase nunca&#8221;, &#8220;de vez em quando&#8221;, &#8220;quase sempre&#8221; e &#8220;sempre&#8221;), correspondendo a uma escala do tipo Likert de 5 pontos.<sup><xref ref-type="bibr" rid="B15">15</xref>,<xref ref-type="bibr" rid="B16">16</xref></sup></p>
        <p>As perguntas do question&#225;rio est&#227;o relacionadas ao medo e &#224; ansiedade dos pacientes em raz&#227;o da expectativa de o dispositivo aplicar terapias de choque, bem como a mudan&#231;as comportamentais (n&#227;o realizar exerc&#237;cios f&#237;sicos ou atividade sexual, n&#227;o ficar nervoso ou com raiva, por exemplo) adotadas para evitar a ocorr&#234;ncia de terapias de choque, a partir da perspectiva do paciente.</p>
        <p>O escore total do instrumento FSAS &#233; determinado pela soma de todos os itens, podendo atingir pontua&#231;&#227;o m&#225;xima de 50 pontos. Quanto maior a pontua&#231;&#227;o, maior o n&#237;vel de ansiedade, sendo que os itens que atingem tr&#234;s ou mais pontos devem ser considerados os aspectos mais cr&#237;ticos.<sup><xref ref-type="bibr" rid="B17">17</xref>,<xref ref-type="bibr" rid="B18">18</xref></sup> O instrumento pode ser autoadministrado ou aplicado na forma de entrevista.</p>
      </sec>
      <sec>
        <title>Fase 1 - Tradu&#231;&#227;o e adapta&#231;&#227;o transcultural do instrumento</title>
        <p>O processo de adapta&#231;&#227;o transcultural do instrumento FSAS seguiu as recomenda&#231;&#245;es internacionais e constou de cinco etapas: (1) Tradu&#231;&#227;o por dois colaboradores independentes; (2) Consolida&#231;&#227;o das tradu&#231;&#245;es pelo comit&#234; de especialistas; (3) Retrotradu&#231;&#227;o; (4) Harmoniza&#231;&#227;o das vers&#245;es pelo comit&#234; de especialistas; (5) Pr&#233;-teste com a popula&#231;&#227;o alvo; (6) Revis&#227;o do pr&#233;-teste e versionamento final.<sup><xref ref-type="bibr" rid="B23">23</xref>-<xref ref-type="bibr" rid="B25">25</xref></sup> O comit&#234; de especialistas foi constitu&#237;do por profissionais da &#225;rea da estimula&#231;&#227;o card&#237;aca artificial e enfermeiros.</p>
        <p>A tradu&#231;&#227;o do instrumento original para a l&#237;ngua portuguesa foi realizada por dois colaboradores independentes, brasileiros com profici&#234;ncia na l&#237;ngua portuguesa e inglesa. Nessa etapa, as vers&#245;es elaboradas pelos dois tradutores independentes (T<sub>1</sub> e T<sub>2</sub>) foram consolidadas em uma &#250;nica vers&#227;o (T<sub>1-2</sub>), ap&#243;s discuss&#227;o com o comit&#234; de especialistas. A partir dessa vers&#227;o traduzida, foi realizada a etapa da retrotradu&#231;&#227;o (RT<sub>1</sub> e RT<sub>2</sub>) por dois professores bil&#237;ngues que n&#227;o tinham tido contato pr&#233;vio com o instrumento original. A finalidade dessa etapa foi aferir a consist&#234;ncia sem&#226;ntica e idiom&#225;tica das tradu&#231;&#245;es realizadas na primeira etapa. Finalmente, foi realizada uma nova reuni&#227;o com o comit&#234; de especialistas para revisar todo o processo de adapta&#231;&#227;o transcultural e realizar a harmoniza&#231;&#227;o das vers&#245;es, obtendo-se, assim, a vers&#227;o pr&#233;-final do instrumento. (<xref ref-type="fig" rid="f01">Figura 1</xref>)</p>
        <p>
          <fig id="f01">
            <label>Figura 1</label>
            <caption>
              <title>&#8211; <italic>Processo de adapta&#231;&#227;o transcultural do instrumento FSAS.</italic></title>
            </caption>
            <graphic xlink:href="1678-4170-abc-114-05-0764-90255-gf01.jpg"/></fig>
        </p>
        <p>A vers&#227;o pr&#233;-teste foi administrada em uma amostra de conveni&#234;ncia de 20 participantes, com idades entre 18 e 80 anos, portadores de CDI por pelo menos seis meses e que realizavam acompanhamento cl&#237;nico em nossa institui&#231;&#227;o. O pr&#233;-teste foi realizado para identificar e corrigir poss&#237;veis problemas de tradu&#231;&#227;o. Ap&#243;s o preenchimento do instrumento pelo pr&#243;prio indiv&#237;duo, realizou-se uma entrevista de esclarecimento, para verificar se havia itens de dif&#237;cil compreens&#227;o ou irrelevantes, assim como aferir a compreens&#227;o de cada item do instrumento. O crit&#233;rio estabelecido para revis&#227;o e modifica&#231;&#227;o da tradu&#231;&#227;o foi a compreens&#227;o dos itens por menos de 80% dos entrevistados.</p>
      </sec>
      <sec>
        <title>Fase 2 &#8211; Valida&#231;&#227;o de construto do instrumento FSAS</title>
        <p>A vers&#227;o final em portugu&#234;s do instrumento FSAS foi administrada em uma amostra de conveni&#234;ncia de 151 participantes com as seguintes caracter&#237;sticas: (1) adultos, com idades entre 18 a 80 anos, de ambos os sexos e com qualquer n&#237;vel de escolaridade; (2) portadores de CDI h&#225; mais de seis meses; (3) capacidade de compreender e responder &#224;s perguntas do question&#225;rio utilizado no estudo; (4) concord&#226;ncia em participar do estudo, com assinatura do TCLE. N&#227;o foram inclu&#237;dos no estudo os indiv&#237;duos que apresentaram ao menos uma das seguintes situa&#231;&#245;es: (1) indica&#231;&#227;o de transplante card&#237;aco; (2) gesta&#231;&#227;o em curso; (3) neoplasias malignas.</p>
        <p>Os pacientes foram selecionados, de forma consecutiva, durante o atendimento ambulatorial ou mediante visitas realizadas &#224; Unidade de Interna&#231;&#227;o da nossa institui&#231;&#227;o. Os indiv&#237;duos que preencheram os crit&#233;rios de elegibilidade foram convidados a responder o question&#225;rio FSAS. Nesse mesmo momento, era realizado o levantamento do hist&#243;rico cl&#237;nico e obtidas informa&#231;&#245;es sobre o implante do CDI, terapias de choque pr&#233;vias e uso de medicamentos.</p>
        <p>Todos os dados foram coletados diretamente em <italic>tablets</italic>, utilizando-se formul&#225;rios eletr&#244;nicos desenvolvidos no sistema <italic>Research Electronic Data Capture</italic> (REDCap)<sup><xref ref-type="bibr" rid="B26">26</xref></sup> hospedado no servidor da nossa institui&#231;&#227;o.</p>
        <sec>
          <title>N&#250;mero amostral</title>
          <p>O dimensionamento do n&#250;mero de participantes nos estudos psicom&#233;tricos usualmente &#233; feito sobre o n&#250;mero de itens dos instrumentos avaliados. Alguns estudos demonstraram que uma rela&#231;&#227;o de 20:1 ou superior, ou seja, 20 participantes para cada item do instrumento, seria o ideal. Contudo, rela&#231;&#245;es de 10:1 j&#225; permitem an&#225;lises adequadas. Desse modo, foi estabelecido o m&#237;nimo amostral de 150 pacientes.<sup><xref ref-type="bibr" rid="B25">25</xref></sup></p>
        </sec>
      </sec>
    </sec>
    <sec>
      <title>An&#225;lise Estat&#237;stica</title>
      <sec>
        <title>An&#225;lise descritiva</title>
        <p>Foi realizada uma an&#225;lise descritiva minuciosa utilizando medidas de tend&#234;ncia central (m&#233;dia, desvio padr&#227;o, mediana, m&#233;dia aparada, intervalos de confian&#231;a e intervalo interquartil). O teste de Kolmogorov-Smirnov (KS) foi utilizado para a testagem isolada da normalidade de cada item do question&#225;rio, enquanto que o Teste de Mardia foi empregado para verificar a normalidade multivariada.</p>
        <p>Todas as an&#225;lises foram realizadas nos softwares SPSS 23.0 e Factor 10.8.01, adotando-se o n&#237;vel de signific&#226;ncia de 5%.</p>
      </sec>
      <sec>
        <title>Validade de construto e dimensionalidade</title>
        <p>Neste estudo, foram realizadas as an&#225;lises fatoriais explorat&#243;ria (AFEs) e confirmat&#243;ria (AFC) para verificar a dimensionalidade do instrumento FSAS em sua vers&#227;o na l&#237;ngua portuguesa.</p>
        <p>A testagem da dimensionalidade foi realizada pela An&#225;lise Paralela Robusta (APR), por meio da <italic>Optimal Implementation of Parallel Analysis</italic> (PA), com minimum rank factor analysis (MRFA), que minimiza a vari&#226;ncia comum dos res&#237;duos.<sup><xref ref-type="bibr" rid="B27">27</xref>,<xref ref-type="bibr" rid="B28">28</xref></sup>A robustez do teste foi determinada a partir da associa&#231;&#227;o de um <italic>bootstrap</italic> com uma extrapola&#231;&#227;o amostral para 5000. A extra&#231;&#227;o dos fatores foi feita inicialmente com RULS (<italic>Robust Unweighted Least Squares</italic>), que reduz os res&#237;duos das matrizes.<sup><xref ref-type="bibr" rid="B29">29</xref></sup></p>
      </sec>
      <sec>
        <title>Teoria de Resposta ao Item</title>
        <p>Foi utilizado o &#237;ndice de discrimina&#231;&#227;o do item (a), que mede a for&#231;a de associa&#231;&#227;o entre o item e a vari&#225;vel latente e tem interpreta&#231;&#227;o similar &#224;s cargas fatoriais da AFE.</p>
      </sec>
      <sec>
        <title>Par&#226;metros de qualidade da vers&#227;o traduzida e adaptada do instrumento FSAS</title>
        <p>Para a adequa&#231;&#227;o dos itens e do modelo, foram considerados os seguintes crit&#233;rios: vari&#226;ncia explicada do modelo (60 a 70%), valores de cargas fatoriais (&gt; 0,50), comunalidades (&gt; 0,40) e discrimina&#231;&#227;o do item, problemas de colinearidade e multicolinearidade (cargas fatoriais acima de 0,80 e 0,85, respectivamente).</p>
      </sec>
      <sec>
        <title>&#205;ndices de ajustamento na An&#225;lise Fatorial Confirmat&#243;ria</title>
        <p>Os &#237;ndices de ajustamento do modelo e os respectivos valores esperados foram: <italic>Robust Mean-Scaled Chi Square/df NNFI</italic> (<italic>Non-Normed Fit Index</italic> &gt; 0,93), CFI (<italic>Comparative Fit Index</italic> &gt; 0,94), GFI (<italic>Goodness Fit Index</italic> &gt; 0,95), AGFI (<italic>Adjusted Goodness Fit Index</italic> &gt; 0,93), RMSEA (<italic>Root Mean Square Error of Approximation</italic> &lt; 0,07) e RMSR (<italic>Root Mean Square of Residuals</italic> &lt; 0,08).29-31</p>
      </sec>
      <sec>
        <title>Confiabilidade</title>
        <p>Foram adotados tr&#234;s indicadores para a avalia&#231;&#227;o da confiabilidade da vers&#227;o brasileira do question&#225;rio FSAS: Alfa de Cronbach, &#212;mega de McDonald e GLB (<italic>Greatest Lower Bound</italic>).</p>
      </sec>
    </sec>
    <sec sec-type="results">
      <title>Resultados</title>
      <sec>
        <title>Vers&#227;o final do instrumento FSAS</title>
        <p>De um modo geral, as etapas de tradu&#231;&#227;o e adapta&#231;&#227;o transcultural produziram vers&#245;es semelhantes do instrumento FSAS. A s&#237;ntese das tradu&#231;&#245;es foi bem concisa e uniu o mais coerente de cada tradu&#231;&#227;o realizada. As vers&#245;es produzidas na retrotradu&#231;&#227;o evidenciaram uma boa qualidade das tradu&#231;&#245;es e do processo de s&#237;ntese realizado nas etapas iniciais.</p>
        <p>Participaram do pr&#233;-teste 20 portadores de CDI, com idade m&#233;dia de 55,6 &#177; 6,8 anos, dos quais 50% eram do sexo feminino, 50% eram brancos e 30% tinham cursado at&#233; o Ensino M&#233;dio. Todos os participantes consideraram os itens relevantes, de f&#225;cil entendimento e compreenderam as op&#231;&#245;es de respostas. Nenhum participante sugeriu modifica&#231;&#245;es no instrumento. Na <xref ref-type="table" rid="t1">Tabela 1</xref> est&#227;o apresentados os itens do instrumento em suas vers&#245;es na l&#237;ngua inglesa e portuguesa.</p>
        <p>
          <table-wrap id="t1">
            <label>Tabela 1</label>
            <caption>
              <title>&#8211; Instrumento original e vers&#227;o brasileira da Florida Shock Anxiety Scale (FSAS-Br)</title>
            </caption>
            <table frame="hsides" rules="groups">
              <colgroup width="33%">
                <col/>
                <col/>
                <col/>
              </colgroup>
              <thead>
                <tr>
                  <th align="left">Item</th>
                  <th>Instrumento Original</th>
                  <th>Vers&#227;o Brasileira: FSAS-Br</th>
                </tr>
              </thead>
              <tbody>
                <tr>
                  <td>1</td>
                  <td align="center">I am scared to exercise because it may increase my heart rate and cause my device to fire.</td>
                  <td align="center">Eu tenho medo de fazer exerc&#237;cios f&#237;sicos porque isso pode aumentar meus batimentos card&#237;acos e fazer o meu CDI me aplicar um choque.</td>
                </tr>
                <tr>
                  <td>2</td>
                  <td align="center">I am afraid of being alone when the ICD fires and I need help.</td>
                  <td align="center">Eu tenho medo de estar sozinho e precisar de ajuda quando o CDI me aplicar um choque.</td>
                </tr>
                <tr>
                  <td>3</td>
                  <td align="center">I do not get angry or upset because it may cause my ICD to fire.</td>
                  <td align="center">Eu n&#227;o posso ficar nervoso ou chateado porque isso pode fazer o CDI me aplicar um choque.</td>
                </tr>
                <tr>
                  <td>4</td>
                  <td align="center">It bothers me that I do not know when the ICD will fire.</td>
                  <td align="center">Me sinto preocupado por n&#227;o saber quando o CDI vai me aplicar um choque.</td>
                </tr>
                <tr>
                  <td>5</td>
                  <td align="center">I worry about the ICD not firing sometime when it should.</td>
                  <td align="center">Eu me preocupo com a possibilidade do CDI n&#227;o funcionar quando eu precisar.</td>
                </tr>
                <tr>
                  <td>6</td>
                  <td align="center">I am afraid to touch others for fear I&#8217;ll shock them if the ICD fires.</td>
                  <td align="center">Eu tenho medo de tocar nas pessoas e dar um choque nelas caso o CDI dispare.</td>
                </tr>
                <tr>
                  <td>7</td>
                  <td align="center">I worry about the ICD firing and creating a scene.</td>
                  <td align="center">Eu me preocupo sobre a possibilidade de assustar as pessoas quando o CDI me aplicar um choque.</td>
                </tr>
                <tr>
                  <td>8</td>
                  <td align="center">When I notice my heart beating rapidly, I worry that the ICD will fire.</td>
                  <td align="center">Quando eu percebo que meu cora&#231;&#227;o bate mais r&#225;pido, eu fico preocupado que o CDI vai me aplicar um choque.</td>
                </tr>
                <tr>
                  <td>9</td>
                  <td align="center">I have unwanted thoughts of my ICD firing.</td>
                  <td align="center">Eu penso o tempo todo que a qualquer momento o CDI pode me aplicar um choque.</td>
                </tr>
                <tr>
                  <td>10</td>
                  <td align="center">I do not engage in sexual activities because it may cause my ICD to fire.</td>
                  <td align="center">Eu n&#227;o tenho rela&#231;&#245;es sexuais porque isso pode fazer o CDI me aplicar um choque.</td>
                </tr>
                <tr>
                  <td>
									</td>
                  <td align="center">Response options <list list-type="order"><list-item><p>Not at all</p></list-item><list-item><p>Rarely</p></list-item><list-item><p>Some of the time</p></list-item><list-item><p>Most of the time</p></list-item><list-item><p>All the time</p></list-item></list>
									</td>
                  <td align="center">Op&#231;&#245;es de resposta <list list-type="order"><list-item><p>Nunca</p></list-item><list-item><p>Quase nunca</p></list-item><list-item><p>Algumas vezes</p></list-item><list-item><p>Na maioria das vezes</p></list-item><list-item><p>Sempre</p></list-item></list>
									</td>
                </tr>
              </tbody>
            </table>
          </table-wrap>
        </p>
      </sec>
      <sec>
        <title>Propriedades psicom&#233;tricas do instrumento FSAS</title>
        <sec>
          <title>Composi&#231;&#227;o da Popula&#231;&#227;o</title>
          <p>Nesta fase do estudo, foram inclu&#237;dos 151 portadores de CDI, com idade m&#233;dia de 55,7&#177;14,1 anos (varia&#231;&#227;o de 19 a 80 anos). Houve predom&#237;nio do sexo masculino que correspondeu a 64% dos casos. A maioria dos pacientes era da ra&#231;a branca (85,4%) e 49% haviam cursado o ensino fundamental (<xref ref-type="table" rid="t2">Tabela 2</xref>).</p>
          <p>
            <table-wrap id="t2">
              <label>Tabela 2</label>
              <caption>
                <title>&#8211; Perfil demogr&#225;fico e cl&#237;nico dos participantes do estudo</title>
              </caption>
              <table frame="hsides" rules="groups">
                <colgroup width="50%">
                  <col/>
                  <col/>
                </colgroup>
                <thead>
                  <tr>
                    <th align="left">Caracter&#237;sticas</th>
                    <th align="left" style="font-weight:normal">
										</th>
                  </tr>
                </thead>
                <tbody>
                  <tr>
                    <td>Sexo masculino</td>
                    <td align="center">64,0%</td>
                  </tr>
                  <tr>
                    <td>Idade (anos)</td>
                    <td align="center">55,7 &#177; 14,1</td>
                  </tr>
                  <tr>
                    <td>Ra&#231;a branca</td>
                    <td align="center">85,4%</td>
                  </tr>
                  <tr>
                    <td>
                      <bold>Escolaridade</bold>
                    </td>
                    <td>
										</td>
                  </tr>
                  <tr>
                    <td>Ensino Superior</td>
                    <td align="center">14,8%</td>
                  </tr>
                  <tr>
                    <td>Ensino M&#233;dio</td>
                    <td align="center">34,9%</td>
                  </tr>
                  <tr>
                    <td>Ensino Fundamental</td>
                    <td align="center">49,0%</td>
                  </tr>
                  <tr>
                    <td>Analfabeto</td>
                    <td align="center">1,3%</td>
                  </tr>
                  <tr>
                    <td>
                      <bold>Estado civil</bold>
                    </td>
                    <td>
										</td>
                  </tr>
                  <tr>
                    <td>Casado</td>
                    <td align="center">64,9%</td>
                  </tr>
                  <tr>
                    <td>Solteiro</td>
                    <td align="center">14,6%</td>
                  </tr>
                  <tr>
                    <td>Divorciado</td>
                    <td align="center">7,9%</td>
                  </tr>
                  <tr>
                    <td>Vi&#250;vo</td>
                    <td align="center">6,6%</td>
                  </tr>
                  <tr>
                    <td>Uni&#227;o est&#225;vel</td>
                    <td align="center">6,0%</td>
                  </tr>
                  <tr>
                    <td>
                      <bold>Doen&#231;a card&#237;aca estrutural</bold>
                    </td>
                    <td>
										</td>
                  </tr>
                  <tr>
                    <td>Doen&#231;a de Chagas</td>
                    <td align="center">30,5%</td>
                  </tr>
                  <tr>
                    <td>Cardiopatia isqu&#234;mica</td>
                    <td align="center">25,2%</td>
                  </tr>
                  <tr>
                    <td>Cardiopatia hipertr&#243;fica</td>
                    <td align="center">14,6%</td>
                  </tr>
                  <tr>
                    <td>Cardiopatia dilatada</td>
                    <td align="center">13,2%</td>
                  </tr>
                  <tr>
                    <td>S&#237;ndrome de Brugada</td>
                    <td align="center">4,6%</td>
                  </tr>
                  <tr>
                    <td>S&#237;ndrome do QT longo cong&#234;nita</td>
                    <td align="center">3,3%</td>
                  </tr>
                  <tr>
                    <td>Displasia arritmog&#234;nica do ventr&#237;culo direito</td>
                    <td align="center">2,6%</td>
                  </tr>
                  <tr>
                    <td>2Outras</td>
                    <td align="center">5,9%</td>
                  </tr>
                  <tr>
                    <td>
                      <bold>Classe Funcional da New York Heart Association</bold>
                    </td>
                    <td>
										</td>
                  </tr>
                  <tr>
                    <td>I</td>
                    <td align="center">37,1%</td>
                  </tr>
                  <tr>
                    <td>II</td>
                    <td align="center">47,7%</td>
                  </tr>
                  <tr>
                    <td>III</td>
                    <td align="center">11,3%</td>
                  </tr>
                  <tr>
                    <td>IV</td>
                    <td align="center">4,0%</td>
                  </tr>
                  <tr>
                    <td>Fra&#231;&#227;o de eje&#231;&#227;o do ventr&#237;culo esquerdo (ecocardiograma)</td>
                    <td align="center">41,2 &#177; 15,6</td>
                  </tr>
                  <tr>
                    <td>
                      <bold>Comorbidades</bold>
                    </td>
                    <td>
										</td>
                  </tr>
                  <tr>
                    <td>Nenhuma</td>
                    <td align="center">29,1%</td>
                  </tr>
                  <tr>
                    <td>Hipertens&#227;o arterial</td>
                    <td align="center">49,5%</td>
                  </tr>
                  <tr>
                    <td>Doen&#231;a arterial coronariana</td>
                    <td align="center">15,9%</td>
                  </tr>
                  <tr>
                    <td>Diabetes</td>
                    <td align="center">20,6%</td>
                  </tr>
                  <tr>
                    <td>Fibrila&#231;&#227;o atrial</td>
                    <td align="center">27,1%</td>
                  </tr>
                  <tr>
                    <td>Insufici&#234;ncia renal cr&#244;nica</td>
                    <td align="center">6,5%</td>
                  </tr>
                  <tr>
                    <td>Dislipidemia</td>
                    <td align="center">51,4%</td>
                  </tr>
                  <tr>
                    <td>&#205;ndice de comorbidades de Charlson</td>
                    <td align="center">1,3 &#177; 1,0</td>
                  </tr>
                  <tr>
                    <td>
                      <bold>Uso de medicamentos</bold>
                    </td>
                    <td>
										</td>
                  </tr>
                  <tr>
                    <td>IECA/ BRA</td>
                    <td align="center">72,7%</td>
                  </tr>
                  <tr>
                    <td>Betabloqueadores</td>
                    <td align="center">85,4%</td>
                  </tr>
                  <tr>
                    <td>Diur&#233;ticos</td>
                    <td align="center">50,7%</td>
                  </tr>
                  <tr>
                    <td>Antiarr&#237;tmicos</td>
                    <td align="center">58,9%</td>
                  </tr>
                  <tr>
                    <td>Antiagregantes plaquet&#225;rios</td>
                    <td align="center">31,8%</td>
                  </tr>
                  <tr>
                    <td>Anticoagulantes orais</td>
                    <td align="center">27,8%</td>
                  </tr>
                  <tr>
                    <td>
                      <bold>Indica&#231;&#227;o do CDI</bold>
                    </td>
                    <td>
										</td>
                  </tr>
                  <tr>
                    <td>Preven&#231;&#227;o prim&#225;ria da morte s&#250;bita</td>
                    <td align="center">19,9%</td>
                  </tr>
                  <tr>
                    <td>Preven&#231;&#227;o secund&#225;ria da morte s&#250;bita</td>
                    <td align="center">80,1%</td>
                  </tr>
                  <tr>
                    <td>
                      <bold>Tipo de CDI</bold>
                    </td>
                    <td>
										</td>
                  </tr>
                  <tr>
                    <td>CDI ventricular</td>
                    <td align="center">41,1%</td>
                  </tr>
                  <tr>
                    <td>CDI atrioventricular</td>
                    <td align="center">46,4%</td>
                  </tr>
                  <tr>
                    <td>CDI com ressincronizador card&#237;aco</td>
                    <td align="center">12,6%</td>
                  </tr>
                  <tr>
                    <td>Tempo de implante do CDI (anos)</td>
                    <td align="center">6,7 &#177; 4,4</td>
                  </tr>
                  <tr>
                    <td>
                      <bold>Terapias do CDI</bold>
                    </td>
                    <td>
										</td>
                  </tr>
                  <tr>
                    <td>Recebeu terapias de choque</td>
                    <td align="center">60,3%</td>
                  </tr>
                  <tr>
                    <td>Nunca recebeu terapias de choque</td>
                    <td align="center">39,7%</td>
                  </tr>
                </tbody>
              </table>
              <table-wrap-foot>
                <fn id="TFN1">
                  <p>
                    <italic>BRA: bloqueador do receptor de angiotensina; IECA: Inibidor da enzima de convers&#227;o da angiotensina</italic>
                  </p>
                </fn>
              </table-wrap-foot>
            </table-wrap>
          </p>
          <p>Dentre as doen&#231;as card&#237;acas, chama a aten&#231;&#227;o a Doen&#231;a de Chagas, que esteve presente em 30,5% dos casos, seguida pela cardiopatia isqu&#234;mica em 25,2%. A S&#237;ndrome de Brugada e a S&#237;ndrome do QT longo cong&#234;nita foram identificadas em 4,6 e 3,3% dos pacientes, respectivamente.</p>
          <p>A avalia&#231;&#227;o basal mostrou que a maioria dos pacientes estava em classe funcional I (37,1%) e II (47,7%), segundo os crit&#233;rios da <italic>New York Heart Association</italic>. A fun&#231;&#227;o ventricular esquerda determinada pelo ecocardiograma transtor&#225;cico bidimensional variou de 18 a 77%, com mediana de 35%.</p>
          <p>Apenas 29,1% dos pacientes n&#227;o apresentavam comorbidades associadas. Dislipidemia e hipertens&#227;o arterial foram as comorbidades mais frequentes, estando presentes em 51,4% e 49,5% dos pacientes, respectivamente. Fibrila&#231;&#227;o atrial estava presente em 27,1% dos indiv&#237;duos estudados (<xref ref-type="table" rid="t2">Tabela 2</xref>).</p>
          <p>Como j&#225; era esperado, 80,1% das indica&#231;&#245;es do CDI corresponderam &#224; profilaxia secund&#225;ria da morte s&#250;bita arr&#237;tmica, visto que, na realidade brasileira, devido &#224; escassez de recursos, o implante de CDI ainda &#233; pouco utilizado para profilaxia prim&#225;ria da morte s&#250;bita.</p>
          <p>Quanto ao tipo de CDI, sistemas unicamerais estavam presentes em 41,1% dos pacientes, seguidos pelos sistemas dupla-c&#226;mara (46,4%). Apenas 12,6% dos pacientes apresentavam CDI com ressincronizador card&#237;aco, por terem doen&#231;a card&#237;aca mais avan&#231;ada. O tempo de uso do CDI foi de 6,7 &#177; 4,4 anos, variando de 6 meses a 16,9 anos. O n&#250;mero expressivo de pacientes (60,3%) que haviam recebido terapias de choque do CDI foi condizente com a indica&#231;&#227;o cl&#237;nica do dispositivo, visto que terapias de choque s&#227;o muito mais frequentes em indiv&#237;duos submetidos &#224; profilaxia secund&#225;ria da morte s&#250;bita.</p>
        </sec>
      </sec>
    </sec>
    <sec>
      <title>An&#225;lise descritiva dos itens do instrumento FSAS</title>
      <p>Atrav&#233;s da an&#225;lise descritiva dos itens do instrumento, foi poss&#237;vel identificar que houve viola&#231;&#227;o da normalidade da distribui&#231;&#227;o, indicando, portanto, a necessidade da utiliza&#231;&#227;o de correla&#231;&#245;es polic&#243;ricas, ao inv&#233;s da correla&#231;&#227;o de Pearson.</p>
      <p>As m&#233;dias dos itens do instrumento variaram de 1,5 a 2,9. O escore m&#233;dio do FSAS foi de 22,8 &#177; 11,1, com mediana de 20 pontos e varia&#231;&#227;o de 10 a 50 pontos. N&#227;o houve efeito de valores extremos na m&#233;dia (<xref ref-type="table" rid="t3">Tabela 3</xref>).</p>
      <p>
        <table-wrap id="t3">
          <label>Tabela 3</label>
          <caption>
            <title>&#8211; An&#225;lise descritiva dos itens da FSAS-Br</title>
          </caption>
          <table frame="hsides" rules="groups">
            <colgroup width="8%">
              <col/>
              <col/>
              <col/>
              <col/>
              <col/>
              <col/>
              <col/>
              <col/>
              <col/>
              <col/>
              <col/>
              <col/>
              <col/>
            </colgroup>
            <thead>
              <tr>
                <th align="left">Item</th>
                <th>M&#233;dia</th>
                <th>DP</th>
                <th>Limite inferior</th>
                <th>Limite superior</th>
                <th>5% da m&#233;dia aparada</th>
                <th>Mediana</th>
                <th>Amplitude</th>
                <th>IQ</th>
                <th>Assimetria</th>
                <th>Curtose</th>
                <th>K-S</th>
                <th>Sig.</th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td>1</td>
                <td align="center">2,95</td>
                <td align="center">1,86</td>
                <td align="center">2,66</td>
                <td align="center">3,25</td>
                <td align="center">2,95</td>
                <td align="center">3,00</td>
                <td align="center">4,00</td>
                <td align="center">4,00</td>
                <td align="center">0,12</td>
                <td align="center">-4,80</td>
                <td align="center">0,29</td>
                <td align="center">0,01</td>
              </tr>
              <tr>
                <td>2</td>
                <td align="center">2,46</td>
                <td align="center">1,72</td>
                <td align="center">2,19</td>
                <td align="center">2,74</td>
                <td align="center">2,40</td>
                <td align="center">1,00</td>
                <td align="center">4,00</td>
                <td align="center">4,00</td>
                <td align="center">2,84</td>
                <td align="center">-3,67</td>
                <td align="center">0,33</td>
                <td align="center">0,01</td>
              </tr>
              <tr>
                <td>3</td>
                <td align="center">2,26</td>
                <td align="center">1,69</td>
                <td align="center">1,99</td>
                <td align="center">2,53</td>
                <td align="center">2,18</td>
                <td align="center">1,00</td>
                <td align="center">4,00</td>
                <td align="center">3,00</td>
                <td align="center">4,06</td>
                <td align="center">-2,90</td>
                <td align="center">0,37</td>
                <td align="center">0,01</td>
              </tr>
              <tr>
                <td>4</td>
                <td align="center">2,47</td>
                <td align="center">1,69</td>
                <td align="center">2,20</td>
                <td align="center">2,74</td>
                <td align="center">2,41</td>
                <td align="center">1,00</td>
                <td align="center">4,00</td>
                <td align="center">3,00</td>
                <td align="center">2,63</td>
                <td align="center">-3,69</td>
                <td align="center">0,33</td>
                <td align="center">0,01</td>
              </tr>
              <tr>
                <td>5</td>
                <td align="center">2,43</td>
                <td align="center">1,62</td>
                <td align="center">2,17</td>
                <td align="center">2,69</td>
                <td align="center">2,37</td>
                <td align="center">2,00</td>
                <td align="center">4,00</td>
                <td align="center">3,00</td>
                <td align="center">2,97</td>
                <td align="center">-3,21</td>
                <td align="center">0,30</td>
                <td align="center">0,01</td>
              </tr>
              <tr>
                <td>6</td>
                <td align="center">1,54</td>
                <td align="center">1,25</td>
                <td align="center">1,34</td>
                <td align="center">1,74</td>
                <td align="center">1,38</td>
                <td align="center">1,00</td>
                <td align="center">4,00</td>
                <td align="center">0,00</td>
                <td align="center">10,81</td>
                <td align="center">7,67</td>
                <td align="center">0,48</td>
                <td align="center">0,01</td>
              </tr>
              <tr>
                <td>7</td>
                <td align="center">2,36</td>
                <td align="center">1,68</td>
                <td align="center">2,09</td>
                <td align="center">2,63</td>
                <td align="center">2,29</td>
                <td align="center">1,00</td>
                <td align="center">4,00</td>
                <td align="center">3,00</td>
                <td align="center">3,34</td>
                <td align="center">-3,30</td>
                <td align="center">0,34</td>
                <td align="center">0,01</td>
              </tr>
              <tr>
                <td>8</td>
                <td align="center">2,74</td>
                <td align="center">1,72</td>
                <td align="center">2,47</td>
                <td align="center">3,02</td>
                <td align="center">2,71</td>
                <td align="center">3,00</td>
                <td align="center">4,00</td>
                <td align="center">4,00</td>
                <td align="center">1,30</td>
                <td align="center">-4,14</td>
                <td align="center">0,28</td>
                <td align="center">0,01</td>
              </tr>
              <tr>
                <td>9</td>
                <td align="center">2,07</td>
                <td align="center">1,59</td>
                <td align="center">1,81</td>
                <td align="center">2,32</td>
                <td align="center">1,96</td>
                <td align="center">1,00</td>
                <td align="center">4,00</td>
                <td align="center">2,00</td>
                <td align="center">5,37</td>
                <td align="center">-1,56</td>
                <td align="center">0,39</td>
                <td align="center">0,01</td>
              </tr>
              <tr>
                <td>10</td>
                <td align="center">1,54</td>
                <td align="center">1,24</td>
                <td align="center">1,34</td>
                <td align="center">1,74</td>
                <td align="center">1,37</td>
                <td align="center">1,00</td>
                <td align="center">4,00</td>
                <td align="center">0,00</td>
                <td align="center">10,87</td>
                <td align="center">7,84</td>
                <td align="center">0,49</td>
                <td align="center">0,01</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </p>
    </sec>
    <sec>
      <title>Validade de construto e dimensionalidade do instrumento FSAS</title>
      <p>Os valores obtidos do &#237;ndice de Kaiser-Meyer-Olkin (KMO= 0,88), do teste de esfericidade de Bartlett (X<sup><xref ref-type="bibr" rid="B2">2</xref></sup>= 565,5, df= 45; p&lt; 0,001) e o determinante da matriz (0,0206 (p&lt;0,0001)) revelaram uma correla&#231;&#227;o significativa entre os itens, confirmando a adequa&#231;&#227;o da aplica&#231;&#227;o da AFE.</p>
      <p>A an&#225;lise paralela indicou a exist&#234;ncia de apenas uma dimens&#227;o para o instrumento. Ademais, esse conjunto de itens consegue explicar 64,4% da vari&#225;vel latente (acima dos valores recomendados na literatura). <sup><xref ref-type="bibr" rid="B29">29</xref>-<xref ref-type="bibr" rid="B31">31</xref></sup> O conceito dos autovalores (eigenvalue &gt; 1) tamb&#233;m apontou apenas uma dimens&#227;o com um autovalor de 6,08. O fato de o instrumento ser unidimensional dispensou a necessidade de t&#233;cnicas rotacionais da matriz fatorial. A unidimensionalidade indicou o uso da t&#233;cnica <italic>Normal-ogive graded response model</italic> para a TRI, mais adequada para modelo unidimensional polit&#244;mico.<sup><xref ref-type="bibr" rid="B31">31</xref></sup></p>
      <p>A <xref ref-type="table" rid="t4">tabela 4</xref> apresenta as cargas fatoriais, que variaram de 0,67 a 0,86, representando n&#237;veis excelentes de ader&#234;ncia dos itens &#224; vari&#225;vel latente, acima do crit&#233;rio m&#237;nimo de 0,50, sem ind&#237;cios de multicolinearidade. A unidimensionalidade eliminou a possibilidade de dupla satura&#231;&#227;o (<italic>cross-loading</italic>). As comunalidades variaram de 0,46 a 0,74, com todos os itens acima do limite de 0,40. Para a discrimina&#231;&#227;o do item (a), os valores variaram de 0,91 a 1,71, tamb&#233;m demonstrando boa ader&#234;ncia &#224; vari&#225;vel latente e confirmando os dados obtidos atrav&#233;s das cargas fatoriais.</p>
      <p>
        <table-wrap id="t4">
          <label>Tabela 4</label>
          <caption>
            <title>&#8211; Validade de construto da FSAS-Br: cargas fatoriais, comunalidades, discrimina&#231;&#227;o do item</title>
          </caption>
          <table frame="hsides" rules="groups">
            <colgroup width="25%">
              <col/>
              <col/>
              <col/>
              <col/>
            </colgroup>
            <thead>
              <tr>
                <th align="left">Item</th>
                <th>Cargas fatoriais</th>
                <th style="font-weight:normal">Comunalidades (h<sup>2</sup>)</th>
                <th>Discrimina&#231;&#227;o do item (a)</th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td>1</td>
                <td align="center">0,76</td>
                <td align="center">0,58</td>
                <td align="center">1,17</td>
              </tr>
              <tr>
                <td>2</td>
                <td align="center">0,77</td>
                <td align="center">0,60</td>
                <td align="center">1,22</td>
              </tr>
              <tr>
                <td>3</td>
                <td align="center">0,76</td>
                <td align="center">0,59</td>
                <td align="center">1,19</td>
              </tr>
              <tr>
                <td>4</td>
                <td align="center">0,81</td>
                <td align="center">0,65</td>
                <td align="center">1,37</td>
              </tr>
              <tr>
                <td>5</td>
                <td align="center">0,68</td>
                <td align="center">0,46</td>
                <td align="center">0,93</td>
              </tr>
              <tr>
                <td>6</td>
                <td align="center">0,71</td>
                <td align="center">0,50</td>
                <td align="center">1,00</td>
              </tr>
              <tr>
                <td>7</td>
                <td align="center">0,67</td>
                <td align="center">0,46</td>
                <td align="center">0,91</td>
              </tr>
              <tr>
                <td>8</td>
                <td align="center">0,73</td>
                <td align="center">0,53</td>
                <td align="center">1,05</td>
              </tr>
              <tr>
                <td>9</td>
                <td align="center">0,86</td>
                <td align="center">0,74</td>
                <td align="center">1,71</td>
              </tr>
              <tr>
                <td>10</td>
                <td align="center">0,74</td>
                <td align="center">0,55</td>
                <td align="center">1,11</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </p>
      <p>A AFC revelou um bom ajuste ao modelo unidimensional, com valores semelhantes aos recomendados pela literatura: <italic>Robust Mean and Variance-Adjusted Chi Square</italic> X<sup>2</sup>/ df (35) = 40,40; p &lt; 0,243; NNFI= 0,997; CFI= 0,997; GFI= 0,986; AGFI= 0,982. Os indicadores de res&#237;duos ficaram em n&#237;veis bons (RMSEA= 0,032; RMSR= 0,077), indicando pouca diferen&#231;a entre a matriz original e a matriz gerada pela carga dos fatores.<sup><xref ref-type="bibr" rid="B31">31</xref></sup></p>
    </sec>
    <sec>
      <title>Confiabilidade do instrumento FSAS-Br</title>
      <p>Encontramos evid&#234;ncias satisfat&#243;rias de confiabilidade da escala FSAS-Br, com coeficiente alfa de Cronbach de 0,92, &#212;mega de McDonald de 0,92 e GLB de 0,98.</p>
    </sec>
    <sec sec-type="discussion">
      <title>Discuss&#227;o</title>
      <p>No presente estudo, foi descrito o processo de tradu&#231;&#227;o e adapta&#231;&#227;o transcultural de uma escala de avalia&#231;&#227;o do n&#237;vel de ansiedade relacionado &#224;s terapias de choque do desfibrilador implant&#225;vel, atendendo ao rigor metodol&#243;gico preconizado na literatura internacional.<sup><xref ref-type="bibr" rid="B23">23</xref>-<xref ref-type="bibr" rid="B25">25</xref></sup> A vers&#227;o final da escala FSAS para a l&#237;ngua portuguesa (FSAS-Br) falada no Brasil, apresentou equival&#234;ncia conceitual, sem&#226;ntica, cultural e de mensura&#231;&#227;o em rela&#231;&#227;o aos itens originais no ingl&#234;s.<sup><xref ref-type="bibr" rid="B15">15</xref>,<xref ref-type="bibr" rid="B16">16</xref></sup></p>
      <p>Esfor&#231;os foram empreendidos para incluir pacientes com diferentes perfis sociodemogr&#225;ficos e diferentes tipos de doen&#231;a card&#237;aca para garantir uma representa&#231;&#227;o heterog&#234;nea, visando assegurar a melhor calibra&#231;&#227;o dos itens do instrumento. Desse modo, pacientes com diferentes tipos de CDI (ventricular, atrioventricular ou associado &#224; terapia de ressincroniza&#231;&#227;o card&#237;aca) foram inclu&#237;dos, assim como pacientes com indica&#231;&#227;o de profilaxia prim&#225;ria ou secund&#225;ria da morte s&#250;bita card&#237;aca. N&#227;o obstante, os principais grupos de cardiopatias comuns a esse perfil de pacientes tamb&#233;m foram contemplados, com expressiva preval&#234;ncia da Doen&#231;a de Chagas, cardiopatia isqu&#234;mica e hipertr&#243;fica.</p>
      <p>No cen&#225;rio internacional, a escala FSAS tem sido amplamente utilizada em diferentes contextos, j&#225; que apresenta boa sensibilidade para identificar o n&#237;vel de ansiedade relacionado &#224;s terapias de choque do CDI e tempo reduzido para preenchimento.<sup><xref ref-type="bibr" rid="B15">15</xref>-<xref ref-type="bibr" rid="B22">22</xref></sup> Desse modo, &#233; importante ressaltar que a escala FSAS n&#227;o foi projetada para avaliar aspectos relevantes da adapta&#231;&#227;o ao dispositivo e o seu real impacto na qualidade de vida, fazendo-se necess&#225;ria a utiliza&#231;&#227;o de outros instrumentos para complementar a avalia&#231;&#227;o desses pacientes. Nesse sentido, os autores da escala FSAS desenvolveram outro instrumento, o <italic>Florida Patient Acceptance Survey</italic> (FPAS),<sup><xref ref-type="bibr" rid="B32">32</xref></sup> que visa avaliar a adapta&#231;&#227;o psicossocial dos portadores de dispositivos card&#237;acos implant&#225;veis. Os resultados do processo de adapta&#231;&#227;o transcultural e valida&#231;&#227;o para a l&#237;ngua portuguesa da escala FPAS ser&#227;o publicados oportunamente.</p>
      <p>A comprova&#231;&#227;o das evid&#234;ncias de validade de um instrumento tem sido recomendada pela comunidade cient&#237;fica como forma de verificar se o instrumento realmente mensura a vari&#225;vel latente de interesse com precis&#227;o. Al&#233;m disso, &#233; importante analisar se a estrutura fatorial do instrumento est&#225; adequadamente representada pela sua dimensionalidade, ou seja, o n&#250;mero de dimens&#245;es que comp&#245;em o instrumento de avalia&#231;&#227;o.<sup><xref ref-type="bibr" rid="B27">27</xref>-<xref ref-type="bibr" rid="B31">31</xref></sup> Na publica&#231;&#227;o original do FSAS, os autores postulam que o instrumento &#233; bidimensional, apresentando uma dimens&#227;o composta por 7 itens (&#8220;<italic>Consequence</italic>&#8221;) e outra com 3 itens (&#8220;<italic>Trigger</italic>&#8221;).<sup><xref ref-type="bibr" rid="B15">15</xref></sup> Esse modelo n&#227;o foi reprodut&#237;vel para a vers&#227;o brasileira, visto que todas as an&#225;lises realizadas no presente estudo sustentaram a unidimensionalidade da escala FSAS-Br. Revisitando o estudo de Kuhl et al.,15 &#233; importante ressaltar que a amostra foi constitu&#237;da por apenas 72 participantes, o que pode ter causado impacto nos resultados das an&#225;lises psicom&#233;tricas.</p>
      <p>Posteriormente, a escala FSAS foi submetida a um processo de avalia&#231;&#227;o de suas propriedades psicom&#233;tricas, dessa vez, com uma casu&#237;stica de 443 participantes.16 A AFC mostrou que as duas dimens&#245;es anteriormente identificadas eram altamente correlacionadas a um fator de segunda ordem (&#8220;<italic>Shock anxiety</italic>&#8221;), ou seja, as duas dimens&#245;es identificadas previamente poderiam ser melhor explicadas pela sua associa&#231;&#227;o a um fator comum, que seria a dimens&#227;o &#8220;Ansiedade relacionada ao choque&#8221;. Em virtude desses resultados, os autores passaram a recomendar a utiliza&#231;&#227;o da pontua&#231;&#227;o total da escala FSAS, ao inv&#233;s de subdividi-la nas duas dimens&#245;es anteriormente descritas. Esses resultados corroboraram a estrutura fatorial identificada em nosso estudo.</p>
      <p>As an&#225;lises de confiabilidade da escala FSAS-Br revelaram a precis&#227;o da vers&#227;o brasileira, que foi confirmada pelos valores adequados do coeficiente alfa de Cronbach, &#212;mega de McDonald e GLB. A ado&#231;&#227;o desses tr&#234;s indicadores buscou aumentar a precis&#227;o da interpreta&#231;&#227;o, visto que o coeficiente alfa de Cronbach sofre efeitos da natureza da distribui&#231;&#227;o dos dados e do tamanho da amostra. Al&#233;m disso, seus valores podem estar elevados em decorr&#234;ncia de escalas extensas, de itens paralelos e/ou redundantes ou da cobertura restrita do construto em an&#225;lise, tornando a medida de confiabilidade fr&#225;gil.<sup><xref ref-type="bibr" rid="B33">33</xref></sup></p>
      <p>De um modo geral, os resultados observados no presente estudo demonstraram que o instrumento &#233; confi&#225;vel e v&#225;lido para aplica&#231;&#227;o no Brasil, atendendo adequadamente aos crit&#233;rios de qualidade propostos para medidas de desfechos reportados por pacientes.</p>
      <sec>
        <title>Limita&#231;&#245;es do estudo</title>
        <p>Embora a popula&#231;&#227;o estudada seja maior do que as amostras de v&#225;rias publica&#231;&#245;es anteriores que utilizaram a escala FSAS, a condu&#231;&#227;o de novos estudos com amostras mais robustas &#233; fundamental para a consolida&#231;&#227;o de sua validade e para atestar sua estabilidade nos mais diversos cen&#225;rios e perfis de pacientes com CDI.</p>
        <p>Estudos futuros, analisando a associa&#231;&#227;o dos escores da FSAS-Br com a ocorr&#234;ncia de terapias de choque do CDI e outros par&#226;metros cl&#237;nicos, ser&#227;o &#250;teis para identificar fatores que podem estar associados aos n&#237;veis elevados de ansiedade e, assim, permitir o estabelecimento de interven&#231;&#245;es espec&#237;ficas e personalizadas para esses pacientes.</p>
      </sec>
    </sec>
    <sec sec-type="conclusions">
      <title>Conclus&#245;es</title>
      <p>O instrumento FSAS-Br apresentou evid&#234;ncias consistentes de validade e confiabilidade, podendo-se, portanto, recomendar sua utiliza&#231;&#227;o na popula&#231;&#227;o de portadores de CDI do Brasil, na pr&#225;tica cl&#237;nica e em pesquisas cient&#237;ficas.</p>
    </sec>
  </body>
  <back>
    <ref-list>
      <title>Refer&#234;ncias</title>
      <ref id="B1">
        <label>1</label>
        <mixed-citation>1. Al-Khatib SM, Friedman P, Ellenbogen KA. Defibrillators: Selecting the Right Device for the Right Patient. Circulation. 2016;134(18):1390-404.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Al-Khatib</surname>
              <given-names>SM</given-names>
            </name>
            <name>
              <surname>Friedman</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Ellenbogen</surname>
              <given-names>KA</given-names>
            </name>
          </person-group>
          <article-title>Defibrillators: Selecting the Right Device for the Right Patient</article-title>
          <source>Circulation</source>
          <year>2016</year>
          <volume>134</volume>
          <issue>18</issue>
          <fpage>1390</fpage>
          <lpage>1404</lpage>
        </element-citation>
      </ref>
      <ref id="B2">
        <label>2</label>
        <mixed-citation>2. Colquitt JL, Mendes D, Clegg AJ, Harris P, Cooper K, Picot J, Bryant J. Implantable cardioverter defibrillators for the treatment of arrhythmias and cardiac resynchronization therapy for the treatment of heart failure: systematic review and economic evaluation. Health Technol Assess. 2014;18(56):1-560.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Colquitt</surname>
              <given-names>JL</given-names>
            </name>
            <name>
              <surname>Mendes</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Clegg</surname>
              <given-names>AJ</given-names>
            </name>
            <name>
              <surname>Harris</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Cooper</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Picot</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Bryant</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>Implantable cardioverter defibrillators for the treatment of arrhythmias and cardiac resynchronization therapy for the treatment of heart failure: systematic review and economic evaluation</article-title>
          <source>Health Technol Assess</source>
          <year>2014</year>
          <volume>18</volume>
          <issue>56</issue>
          <fpage>1</fpage>
          <lpage>560</lpage>
        </element-citation>
      </ref>
      <ref id="B3">
        <label>3</label>
        <mixed-citation>3. Winkle RA. Evolution of the implantable cardioverter-defibrillator: from bullets to BBs. J Am Coll Cardiol 2012;60(23):2399-401.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Winkle</surname>
              <given-names>RA</given-names>
            </name>
          </person-group>
          <article-title>Evolution of the implantable cardioverter-defibrillator: from bullets to BBs</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2012</year>
          <volume>60</volume>
          <issue>23</issue>
          <fpage>2399</fpage>
          <lpage>2401</lpage>
        </element-citation>
      </ref>
      <ref id="B4">
        <label>4</label>
        <mixed-citation>4. Camm AJ, Nisam S. European utilization of the implantable defibrillator: has 10 years changed the &#8220;enigma&#8221;? Europace 2010;12:1063-9.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Camm</surname>
              <given-names>AJ</given-names>
            </name>
            <name>
              <surname>Nisam</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
          <article-title>European utilization of the implantable defibrillator: has 10 years changed the &#8220;enigma&#8221;?</article-title>
          <source>Europace</source>
          <year>2010</year>
          <volume>12</volume>
          <fpage>1063</fpage>
          <lpage>1069</lpage>
        </element-citation>
      </ref>
      <ref id="B5">
        <label>5</label>
        <mixed-citation>5. Wilkoff BL, Fauchier L, Stiles MK, Morillo CA, Al-Khatib SM, Almendral J, et al. 2015 HRS/EHRA/APHRS/ SOLAECE Expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing. Heart Rhythm. 2016;13(2):e50&#8211;e86.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Wilkoff</surname>
              <given-names>BL</given-names>
            </name>
            <name>
              <surname>Fauchier</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Stiles</surname>
              <given-names>MK</given-names>
            </name>
            <name>
              <surname>Morillo</surname>
              <given-names>CA</given-names>
            </name>
            <name>
              <surname>Al-Khatib</surname>
              <given-names>SM</given-names>
            </name>
            <name>
              <surname>Almendral</surname>
              <given-names>J</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>2015 HRS/EHRA/APHRS/ SOLAECE Expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing</article-title>
          <source>Heart Rhythm</source>
          <year>2016</year>
          <volume>13</volume>
          <issue>2</issue>
          <fpage>e50</fpage>
          <lpage>e86</lpage>
        </element-citation>
      </ref>
      <ref id="B6">
        <label>6</label>
        <mixed-citation>6. Daubert JP, Zareba W, Cannom DS, McNitt S, Rosero SZ, Wang P, et al. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact. J Am Coll Cardiol. 2008;51(14):1357-65.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Daubert</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>Zareba</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Cannom</surname>
              <given-names>DS</given-names>
            </name>
            <name>
              <surname>McNitt</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Rosero</surname>
              <given-names>SZ</given-names>
            </name>
            <name>
              <surname>Wang</surname>
              <given-names>P</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2008</year>
          <volume>51</volume>
          <issue>14</issue>
          <fpage>1357</fpage>
          <lpage>1365</lpage>
        </element-citation>
      </ref>
      <ref id="B7">
        <label>7</label>
        <mixed-citation>7. Sood N, Ruwald AC, Solomon S, Daubert JP, McNitt S, Polonsky B, et al. Association between myocardial substrate, implantable cardioverter defibrillator shocks and mortality in MADIT-CRT. Eur Heart J. 2014;35(2):106-15.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Sood</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Ruwald</surname>
              <given-names>AC</given-names>
            </name>
            <name>
              <surname>Solomon</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Daubert</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>McNitt</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Polonsky</surname>
              <given-names>B</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Association between myocardial substrate, implantable cardioverter defibrillator shocks and mortality in MADIT-CRT</article-title>
          <source>Eur Heart J</source>
          <year>2014</year>
          <volume>35</volume>
          <issue>2</issue>
          <fpage>106</fpage>
          <lpage>115</lpage>
        </element-citation>
      </ref>
      <ref id="B8">
        <label>8</label>
        <mixed-citation>8. Desai H, Aronow WS, Ahn C, Gandhi K, Hussain S, Lai HM, et al. Risk factors for appropriate cardioverter-defibrillator shocks, inappropriate cardioverter-defibrillator shocks, and time to mortality in 549 patients with heart failure. Am J Cardiol. 2010;105(9):1336-8.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Desai</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Aronow</surname>
              <given-names>WS</given-names>
            </name>
            <name>
              <surname>Ahn</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Gandhi</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Hussain</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Lai</surname>
              <given-names>HM</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Risk factors for appropriate cardioverter-defibrillator shocks, inappropriate cardioverter-defibrillator shocks, and time to mortality in 549 patients with heart failure</article-title>
          <source>Am J Cardiol</source>
          <year>2010</year>
          <volume>105</volume>
          <issue>9</issue>
          <fpage>1336</fpage>
          <lpage>1338</lpage>
        </element-citation>
      </ref>
      <ref id="B9">
        <label>9</label>
        <mixed-citation>9. Ahmad M, Bloomstein L, Roelke M, Bernstein AD, Parsonnet V. Patients&#8217; attitudes towards implanted defibrillator shocks. Pacing Clin Electrophysiol 2000; 23(6):934&#8211;8.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Ahmad</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Bloomstein</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Roelke</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Bernstein</surname>
              <given-names>AD</given-names>
            </name>
            <name>
              <surname>Parsonnet</surname>
              <given-names>V</given-names>
            </name>
          </person-group>
          <article-title>Patients&#8217; attitudes towards implanted defibrillator shocks</article-title>
          <source>Pacing Clin Electrophysiol</source>
          <year>2000</year>
          <volume>23</volume>
          <issue>6</issue>
          <fpage>934</fpage>
          <lpage>938</lpage>
        </element-citation>
      </ref>
      <ref id="B10">
        <label>10</label>
        <mixed-citation>10. Costa R, Silva KR, Mendon&#231;a RC, Nishioka SA, Siqueira SF, Tamaki WT, et al. Incidence of shock and quality of life in young patients with implantable cardioverter-defibrillator. Arq Bras Cardiol. 2007;88(3):258-64.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Costa</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Silva</surname>
              <given-names>KR</given-names>
            </name>
            <name>
              <surname>Mendon&#231;a</surname>
              <given-names>RC</given-names>
            </name>
            <name>
              <surname>Nishioka</surname>
              <given-names>SA</given-names>
            </name>
            <name>
              <surname>Siqueira</surname>
              <given-names>SF</given-names>
            </name>
            <name>
              <surname>Tamaki</surname>
              <given-names>WT</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Incidence of shock and quality of life in young patients with implantable cardioverter-defibrillator</article-title>
          <source>Arq Bras Cardiol</source>
          <year>2007</year>
          <volume>88</volume>
          <issue>3</issue>
          <fpage>258</fpage>
          <lpage>264</lpage>
        </element-citation>
      </ref>
      <ref id="B11">
        <label>11</label>
        <mixed-citation>11. Pedersen SS, Sears SF, Burg MM, Van Den Broek KC. Does ICD indication affect quality of life and levels of distress? Pacing Clin Electrophysiol. 2009; 32(2):153-6.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Pedersen</surname>
              <given-names>SS</given-names>
            </name>
            <name>
              <surname>Sears</surname>
              <given-names>SF</given-names>
            </name>
            <name>
              <surname>Burg</surname>
              <given-names>MM</given-names>
            </name>
            <name>
              <surname>Van Den Broek</surname>
              <given-names>KC</given-names>
            </name>
          </person-group>
          <article-title>Does ICD indication affect quality of life and levels of distress?</article-title>
          <source>Pacing Clin Electrophysiol</source>
          <year>2009</year>
          <volume>32</volume>
          <issue>2</issue>
          <fpage>153</fpage>
          <lpage>156</lpage>
        </element-citation>
      </ref>
      <ref id="B12">
        <label>12</label>
        <mixed-citation>12. Sears SF, Conti JB. Quality of life and psychological functioning of ICD patients. Heart 2002; 87(5): 488&#8211;93.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Sears</surname>
              <given-names>SF</given-names>
            </name>
            <name>
              <surname>Conti</surname>
              <given-names>JB</given-names>
            </name>
          </person-group>
          <article-title>Quality of life and psychological functioning of ICD patients</article-title>
          <source>Heart</source>
          <year>2002</year>
          <volume>87</volume>
          <issue>5</issue>
          <fpage>488</fpage>
          <lpage>493</lpage>
        </element-citation>
      </ref>
      <ref id="B13">
        <label>13</label>
        <mixed-citation>13. Carroll SL, Strachan PH, de Laat S, Schwartz L, Arthur HM. Patients&#8217; decision making to accept or decline an implantable cardioverter defibrillator for primary prevention of sudden cardiac death. Health Expect 2013;16(1):69-79</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Carroll</surname>
              <given-names>SL</given-names>
            </name>
            <name>
              <surname>Strachan</surname>
              <given-names>PH</given-names>
            </name>
            <name>
              <surname>Laat</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Schwartz</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Arthur</surname>
              <given-names>HM</given-names>
            </name>
          </person-group>
          <article-title>Patients&#8217; decision making to accept or decline an implantable cardioverter defibrillator for primary prevention of sudden cardiac death</article-title>
          <source>Health Expect</source>
          <year>2013</year>
          <volume>16</volume>
          <issue>1</issue>
          <fpage>69</fpage>
          <lpage>79</lpage>
        </element-citation>
      </ref>
      <ref id="B14">
        <label>14</label>
        <mixed-citation>14. da Silva KR, Costa R, Rodrigues CG, Schasechter A, Nobre MC, Passman R, et al. Quality of life in patients with implantable cardioverter-defibrillator: systematic review of randomized controlled trials. Eur J Cardiovasc Nurs. 2018;17(3):196-206.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Silva</surname>
              <given-names>KR</given-names>
            </name>
            <name>
              <surname>Costa</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Rodrigues</surname>
              <given-names>CG</given-names>
            </name>
            <name>
              <surname>Schasechter</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Nobre</surname>
              <given-names>MC</given-names>
            </name>
            <name>
              <surname>Passman</surname>
              <given-names>R</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>Quality of life in patients with implantable cardioverter-defibrillator: systematic review of randomized controlled trials</article-title>
          <source>Eur J Cardiovasc Nurs</source>
          <year>2018</year>
          <volume>17</volume>
          <issue>3</issue>
          <fpage>196</fpage>
          <lpage>206</lpage>
        </element-citation>
      </ref>
      <ref id="B15">
        <label>15</label>
        <mixed-citation>15. Kuhl EA, Dixit NK, Walker RL, Conti JB, Sears SF. Measurement of patient fears about implantable cardioverter defibrillator shock: an initial evaluation of the Florida Shock Anxiety Scale. Pacing Clin Electrophysiol. 2006;29(6):614-8.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Kuhl</surname>
              <given-names>EA</given-names>
            </name>
            <name>
              <surname>Dixit</surname>
              <given-names>NK</given-names>
            </name>
            <name>
              <surname>Walker</surname>
              <given-names>RL</given-names>
            </name>
            <name>
              <surname>Conti</surname>
              <given-names>JB</given-names>
            </name>
            <name>
              <surname>Sears</surname>
              <given-names>SF</given-names>
            </name>
          </person-group>
          <article-title>Measurement of patient fears about implantable cardioverter defibrillator shock: an initial evaluation of the Florida Shock Anxiety Scale</article-title>
          <source>Pacing Clin Electrophysiol</source>
          <year>2006</year>
          <volume>29</volume>
          <issue>6</issue>
          <fpage>614</fpage>
          <lpage>618</lpage>
        </element-citation>
      </ref>
      <ref id="B16">
        <label>16</label>
        <mixed-citation>16. Ford J, Finch JF, Woodrow LK, Cutitta KE, Shea J, Fischer A, et al. The Florida Shock Anxiety Scale (FSAS) for patients with implantable cardioverter defibrillators: testing factor structure, reliability, and validity of a previously established measure. Pacing Clin Electrophysiol. 2012;35(9):1146-53.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Ford</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Finch</surname>
              <given-names>JF</given-names>
            </name>
            <name>
              <surname>Woodrow</surname>
              <given-names>LK</given-names>
            </name>
            <name>
              <surname>Cutitta</surname>
              <given-names>KE</given-names>
            </name>
            <name>
              <surname>Shea</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Fischer</surname>
              <given-names>A</given-names>
            </name>
            <etal>et al</etal>
          </person-group>
          <article-title>The Florida Shock Anxiety Scale (FSAS) for patients with implantable cardioverter defibrillators: testing factor structure, reliability, and validity of a previously established measure</article-title>
          <source>Pacing Clin Electrophysiol</source>
          <year>2012</year>
          <volume>35</volume>
          <issue>9</issue>
          <fpage>1146</fpage>
          <lpage>1153</lpage>
        </element-citation>
      </ref>
      <ref id="B17">
        <label>17</label>
        <mixed-citation>17. Versteeg H, Starrenburg A, Denollet J, Palen Jv, Sears SF, Pedersen SS. Monitoring device acceptance in implantable cardioverter defibrillator patients using the Florida Patient Acceptance Survey. Pacing Clin Electrophysiol. 2012;35(3):283-93.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Versteeg</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Starrenburg</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Denollet</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Jv</surname>
              <given-names>Palen</given-names>
            </name>
            <name>
              <surname>Sears</surname>
              <given-names>SF</given-names>
            </name>
            <name>
              <surname>Pedersen</surname>
              <given-names>SS</given-names>
            </name>
          </person-group>
          <article-title>Monitoring device acceptance in implantable cardioverter defibrillator patients using the Florida Patient Acceptance Survey</article-title>
          <source>Pacing Clin Electrophysiol</source>
          <year>2012</year>
          <volume>35</volume>
          <issue>3</issue>
          <fpage>283</fpage>
          <lpage>293</lpage>
        </element-citation>
      </ref>
      <ref id="B18">
        <label>18</label>
        <mixed-citation>18. Pedersen SS, Spindler H, Johansen JB, Mortensen PT, Sears SF. Correlates of patient acceptance of the cardioverter defibrillator: cross-validation of the Florida Patient Acceptance Survey in Danish patients. Pacing Clin Electrophysiol. 2008;31(9):1168-77</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Pedersen</surname>
              <given-names>SS</given-names>
            </name>
            <name>
              <surname>Spindler</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Johansen</surname>
              <given-names>JB</given-names>
            </name>
            <name>
              <surname>Mortensen</surname>
              <given-names>PT</given-names>
            </name>
            <name>
              <surname>Sears</surname>
              <given-names>SF</given-names>
            </name>
          </person-group>
          <article-title>Correlates of patient acceptance of the cardioverter defibrillator: cross-validation of the Florida Patient Acceptance Survey in Danish patients</article-title>
          <source>Pacing Clin Electrophysiol</source>
          <year>2008</year>
          <volume>31</volume>
          <issue>9</issue>
          <fpage>1168</fpage>
          <lpage>1177</lpage>
        </element-citation>
      </ref>
      <ref id="B19">
        <label>19</label>
        <mixed-citation>19. Kocha&#324;ska A, Zarzycka B, &#346;wi&#261;tecka G, Majkowicz M, Koz&#322;owski D, Raczak G.Quality of life in patients with an implantable cardioverter-defibrillator &#8211; the significance of clinical factors. Arch Med Sci 2008; 4(4):409-16.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Kocha&#324;ska</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Zarzycka</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>&#346;wi&#261;tecka</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Majkowicz</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Koz&#322;owski</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Raczak</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
          <article-title>Quality of life in patients with an implantable cardioverter-defibrillator &#8211; the significance of clinical factors</article-title>
          <source>Arch Med Sci</source>
          <year>2008</year>
          <volume>4</volume>
          <issue>4</issue>
          <fpage>409</fpage>
          <lpage>416</lpage>
        </element-citation>
      </ref>
      <ref id="B20">
        <label>20</label>
        <mixed-citation>20. Chair SY, Lee CK, Choi KC, Sears SF. Quality of life outcomes in chinese patients with implantable cardioverter defibrillators. Pacing Clin Electrophysiol. 2011;34(7):858-67</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Chair</surname>
              <given-names>SY</given-names>
            </name>
            <name>
              <surname>Lee</surname>
              <given-names>CK</given-names>
            </name>
            <name>
              <surname>Choi</surname>
              <given-names>KC</given-names>
            </name>
            <name>
              <surname>Sears</surname>
              <given-names>SF</given-names>
            </name>
          </person-group>
          <article-title>Quality of life outcomes in chinese patients with implantable cardioverter defibrillators</article-title>
          <source>Pacing Clin Electrophysiol</source>
          <year>2011</year>
          <volume>34</volume>
          <issue>7</issue>
          <fpage>858</fpage>
          <lpage>867</lpage>
        </element-citation>
      </ref>
      <ref id="B21">
        <label>21</label>
        <mixed-citation>21. Morken IM, Isaksen K, Karlsen B, Norekv&#229;l TM, Bru E, Larsen AI. Shock anxiety among implantable cardioverter defibrillator recipients with recent tachyarrhythmia. Pacing Clin Electrophysiol. 2012;35(11):1369-76</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Morken</surname>
              <given-names>IM</given-names>
            </name>
            <name>
              <surname>Isaksen</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Karlsen</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Norekv&#229;l</surname>
              <given-names>TM</given-names>
            </name>
            <name>
              <surname>Bru</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Larsen</surname>
              <given-names>AI</given-names>
            </name>
          </person-group>
          <article-title>Shock anxiety among implantable cardioverter defibrillator recipients with recent tachyarrhythmia</article-title>
          <source>Pacing Clin Electrophysiol</source>
          <year>2012</year>
          <volume>35</volume>
          <issue>11</issue>
          <fpage>1369</fpage>
          <lpage>1376</lpage>
        </element-citation>
      </ref>
      <ref id="B22">
        <label>22</label>
        <mixed-citation>22. Oz Alkan H, En&#231; N. Validity and reliability of the Florida Patient Acceptance Survey and Florida Shock Anxiety Scale in Turkish patients with implantable cardioverter defibrillation. Int J Med Res Health Sci 2017,6(10):21-32.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Oz Alkan</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>En&#231;</surname>
              <given-names>N</given-names>
            </name>
          </person-group>
          <article-title>Validity and reliability of the Florida Patient Acceptance Survey and Florida Shock Anxiety Scale in Turkish patients with implantable cardioverter defibrillation</article-title>
          <source>Int J Med Res Health Sci</source>
          <year>2017</year>
          <volume>6</volume>
          <issue>10</issue>
          <fpage>21</fpage>
          <lpage>32</lpage>
        </element-citation>
      </ref>
      <ref id="B23">
        <label>23</label>
        <mixed-citation>23. Wild D, Grove A, Martin M. Principles of good practice for the translation and cultural adaptation process for patient-reported outcomes (PRO) measures: report of the ISPOR task force for translating adaptation. Value Health&gt; 2005;8(2):94-104.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Wild</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Grove</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Martin</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Principles of good practice for the translation and cultural adaptation process for patient-reported outcomes (PRO) measures: report of the ISPOR task force for translating adaptation</article-title>
          <source>Value Health&gt;</source>
          <year>2005</year>
          <volume>8</volume>
          <issue>2</issue>
          <fpage>94</fpage>
          <lpage>104</lpage>
        </element-citation>
      </ref>
      <ref id="B24">
        <label>24</label>
        <mixed-citation>24. Beaton D, Bombardier C, Guillemin F, Ferraz MB. Guidelines for the process of cross-cultural adaptation of self-report measures. Spine (Phila Pa 1976). 2000;25(24):3186-91.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Beaton</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Bombardier</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Guillemin</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Ferraz</surname>
              <given-names>MB</given-names>
            </name>
          </person-group>
          <article-title>Guidelines for the process of cross-cultural adaptation of self-report measures</article-title>
          <source>Spine (Phila Pa 1976)</source>
          <year>2000</year>
          <volume>25</volume>
          <issue>24</issue>
          <fpage>3186</fpage>
          <lpage>3191</lpage>
        </element-citation>
      </ref>
      <ref id="B25">
        <label>25</label>
        <mixed-citation>25. Sousa VD, Rojjanasrirat WJ. Translation, adaptation and validation of instruments or scales for use in cross-cultural health care research: a clear and user-friendly guideline. Eval Clin Pract. 2011;17(2):268-74.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Sousa</surname>
              <given-names>VD</given-names>
            </name>
            <name>
              <surname>Rojjanasrirat</surname>
              <given-names>WJ</given-names>
            </name>
          </person-group>
          <article-title>Translation, adaptation and validation of instruments or scales for use in cross-cultural health care research: a clear and user-friendly guideline</article-title>
          <source>Eval Clin Pract</source>
          <year>2011</year>
          <volume>17</volume>
          <issue>2</issue>
          <fpage>268</fpage>
          <lpage>274</lpage>
        </element-citation>
      </ref>
      <ref id="B26">
        <label>26</label>
        <mixed-citation>26. Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG. Research electronic data capture (REDCap) - A metadata-driven methodology and workflow process for providing translational research informatics support, J Biomed Inform. 2009;42(2):377-81.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Harris</surname>
              <given-names>PA</given-names>
            </name>
            <name>
              <surname>Taylor</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Thielke</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Payne</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Gonzalez</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Conde</surname>
              <given-names>JG</given-names>
            </name>
          </person-group>
          <article-title>Research electronic data capture (REDCap) - A metadata-driven methodology and workflow process for providing translational research informatics support</article-title>
          <source>J Biomed Inform</source>
          <year>2009</year>
          <volume>42</volume>
          <issue>2</issue>
          <fpage>377</fpage>
          <lpage>381</lpage>
        </element-citation>
      </ref>
      <ref id="B27">
        <label>27</label>
        <mixed-citation>27. Timmerman ME, Lorenzo-Seva U. Dimensionality assessment of ordered polytomous items with parallel analysis. Psychol Methods. 2011;16(2):209-20.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Timmerman</surname>
              <given-names>ME</given-names>
            </name>
            <name>
              <surname>Lorenzo-Seva</surname>
              <given-names>U</given-names>
            </name>
          </person-group>
          <article-title>Dimensionality assessment of ordered polytomous items with parallel analysis</article-title>
          <source>Psychol Methods</source>
          <year>2011</year>
          <volume>16</volume>
          <issue>2</issue>
          <fpage>209</fpage>
          <lpage>220</lpage>
        </element-citation>
      </ref>
      <ref id="B28">
        <label>28</label>
        <mixed-citation>28. Lorenzo-Seva, U. How to report the percentage of explained common variance in exploratory factor analysis. Tarragona (Italia):Universita Technical Report. Department of Psychology, Universitat Rovira i Virgili, Tarragona (Italia): Universita Rovira-Virgili; 2013, (Technical Report).</mixed-citation>
        <element-citation publication-type="book">
          <person-group person-group-type="author">
            <name>
              <surname>Lorenzo-Seva</surname>
              <given-names>U</given-names>
            </name>
          </person-group>
          <source>How to report the percentage of explained common variance in exploratory factor analysis</source>
          <publisher-loc>Tarragona (Italia)</publisher-loc>
          <publisher-name>Universita Technical Report. Department of Psychology, Universitat Rovira i Virgili, Tarragona (Italia): Universita Rovira-Virgili</publisher-name>
          <year>2013</year>
          <comment>Technical Report</comment>
        </element-citation>
      </ref>
      <ref id="B29">
        <label>29</label>
        <mixed-citation>29. Briggs NE, MacCallum RC. Recovery of Weak Common Factors by Maximum Likelihood and Ordinary Least Squares Estimation. Multivariate Behav Res. 2003;38(1):25-56.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Briggs</surname>
              <given-names>NE</given-names>
            </name>
            <name>
              <surname>MacCallum</surname>
              <given-names>RC</given-names>
            </name>
          </person-group>
          <article-title>Recovery of Weak Common Factors by Maximum Likelihood and Ordinary Least Squares Estimation</article-title>
          <source>Multivariate Behav Res</source>
          <year>2003</year>
          <volume>38</volume>
          <issue>1</issue>
          <fpage>25</fpage>
          <lpage>56</lpage>
        </element-citation>
      </ref>
      <ref id="B30">
        <label>30</label>
        <mixed-citation>30. Matt C. Howard. A Review of Exploratory Factor Analysis Decisions and Overview of Current Practices: What We Are Doing and How Can We Improve? Int J Hum Comput Interact. 2016;32(1):51-62.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Howard</surname>
              <given-names>Matt C.</given-names>
            </name>
          </person-group>
          <article-title>A Review of Exploratory Factor Analysis Decisions and Overview of Current Practices: What We Are Doing and How Can We Improve?</article-title>
          <source>Int J Hum Comput Interact</source>
          <year>2016</year>
          <volume>32</volume>
          <issue>1</issue>
          <fpage>51</fpage>
          <lpage>62</lpage>
        </element-citation>
      </ref>
      <ref id="B31">
        <label>31</label>
        <mixed-citation>31. Kahn JH. Factor analysis in counseling psychology research, training, and practice: principles, advances, and applications. Couns Psychol. 2006;34(5):684-718.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Kahn</surname>
              <given-names>JH</given-names>
            </name>
          </person-group>
          <article-title>Factor analysis in counseling psychology research, training, and practice: principles, advances, and applications</article-title>
          <source>Couns Psychol</source>
          <year>2006</year>
          <volume>34</volume>
          <issue>5</issue>
          <fpage>684</fpage>
          <lpage>718</lpage>
        </element-citation>
      </ref>
      <ref id="B32">
        <label>32</label>
        <mixed-citation>32. Burns JL, Serber ER, Keim S, Sears SF. Measuring patient acceptance of implantable cardiac device therapy: initial psychometric investigation of the Florida Patient Acceptance Survey. J Cardiovasc Electrophysiol. 2005;16(4):384-90.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Burns</surname>
              <given-names>JL</given-names>
            </name>
            <name>
              <surname>Serber</surname>
              <given-names>ER</given-names>
            </name>
            <name>
              <surname>Keim</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Sears</surname>
              <given-names>SF</given-names>
            </name>
          </person-group>
          <article-title>Measuring patient acceptance of implantable cardiac device therapy: initial psychometric investigation of the Florida Patient Acceptance Survey</article-title>
          <source>J Cardiovasc Electrophysiol</source>
          <year>2005</year>
          <volume>16</volume>
          <issue>4</issue>
          <fpage>384</fpage>
          <lpage>390</lpage>
        </element-citation>
      </ref>
      <ref id="B33">
        <label>33</label>
        <mixed-citation>33. Panayides P. Coefficient alpha: interpret with caution. Eur J Psychol. 2013;9(4):687-96.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Panayides</surname>
              <given-names>P</given-names>
            </name>
          </person-group>
          <article-title>Coefficient alpha: interpret with caution</article-title>
          <source>Eur J Psychol</source>
          <year>2013</year>
          <volume>9</volume>
          <issue>4</issue>
          <fpage>687</fpage>
          <lpage>696</lpage>
        </element-citation>
      </ref>
    </ref-list>
    <fn-group>
      <fn fn-type="other">
        <p>Vincula&#231;&#227;o acad&#234;mica</p>
        <p>N&#227;o h&#225; vincula&#231;&#227;o deste estudo a programas de p&#243;s-gradua&#231;&#227;o.</p>
      </fn>
      <fn fn-type="other">
        <p>Aprova&#231;&#227;o &#233;tica e consentimento informado</p>
        <p>Este estudo foi aprovado pelo Comit&#234; de &#201;tica da CAPPesq sob o n&#250;mero de protocolo CAAE:54522516.2.000.0068. Todos os procedimentos envolvidos nesse estudo est&#227;o de acordo com a Declara&#231;&#227;o de Helsinki de 1975, atualizada em 2013. O consentimento informado foi obtido de todos os participantes inclu&#237;dos no estudo.</p>
      </fn>
    </fn-group>
    <fn-group>
      <fn fn-type="financial-disclosure">
        <p>Fontes de financiamento</p>
        <p>O presente estudo foi financiado pela FAPESP, na modalidade Aux&#237;lio &#224; Pesquisa (Processo 2016/02104-6).</p>
      </fn>
    </fn-group>
  </back>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Validity Evidence of the Brazilian Version of the Florida Shock Anxiety Scale for Patients with Implantable Cardioverter Defibrillators</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-5723-8285</contrib-id>
          <name>
            <surname>Silva</surname>
            <given-names>Katia Regina</given-names>
          </name>
          <xref ref-type="aff" rid="aff1001">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Costa</surname>
            <given-names>Roberto</given-names>
          </name>
          <xref ref-type="aff" rid="aff1001">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Melo</surname>
            <given-names>Giovanna Regina Garcia de Oliveira</given-names>
          </name>
          <xref ref-type="aff" rid="aff1001">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-3746-3266</contrib-id>
          <name>
            <surname>Rebustini</surname>
            <given-names>Fl&#225;vio</given-names>
          </name>
          <xref ref-type="aff" rid="aff2001">
            <sup>2</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0003-1283-9746</contrib-id>
          <name>
            <surname>Benedetto</surname>
            <given-names>Marcos Sidney</given-names>
          </name>
          <xref ref-type="aff" rid="aff1001">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-0181-8651</contrib-id>
          <name>
            <surname>Nagumo</surname>
            <given-names>Marcia Mitie</given-names>
          </name>
          <xref ref-type="aff" rid="aff1001">
            <sup>1</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Sears</surname>
            <given-names>Samuel F.</given-names>
          </name>
          <xref ref-type="aff" rid="aff3001">
            <sup>3</sup>
          </xref>
        </contrib>
      </contrib-group>
      <aff id="aff1001">
        <label>1</label>
        <country country="BR">Brazil</country>
        <institution content-type="original">Instituto do Cora&#231;&#227;o (InCor) - Faculdade de Medicina da Universidade de S&#227;o Paulo, S&#227;o Paulo, SP &#8211; Brazil</institution>
      </aff>
      <aff id="aff2001">
        <label>2</label>
        <country country="BR">Brazil</country>
        <institution content-type="original">Universidade de S&#227;o Paulo - Escola de Artes, Ci&#234;ncias e Humanidades, S&#227;o Paulo, SP - Brazil</institution>
      </aff>
      <aff id="aff3001">
        <label>3</label>
        <country country="US">USA</country>
        <institution content-type="original">East Carolina University - Department of Psychology and Cardiovascular Sciences Greenville, North Carolina &#8211; USA</institution>
      </aff>
      <author-notes>
        <corresp id="c01001"> Mailing Address: Katia Regina Silva &#8226; Instituto do Cora&#231;&#227;o do Hospital das Cl&#237;nicas da Faculdade de Medicina da Universidade de S&#227;o Paulo - Unidade de Estimula&#231;&#227;o El&#233;trica e Marcapasso - Dr. En&#233;as de Carvalho Aguiar, 44. Postal Code 05403-900, S&#227;o Paulo, SP &#8211; Brazil E-mail: katia.regina@incor.usp.br </corresp>
        <fn fn-type="con">
          <p>Author contributions</p>
          <p>Conception and design of the research: Silva KR, Costa R; Acquisition of data: Melo GRGO, Benedetto MS; Analysis and interpretation of the data: Silva KR, Rebustini F; Statistical analysis: Rebustini F; Obtaining financing and writing of the manuscript: Silva KR; Critical revision of the manuscript for intellectual content: Costa R, Rebustini F, Nagumo MM, Sears SF.</p>
        </fn>
        <fn fn-type="conflict">
          <p>Potential Conflict of Interest</p>
          <p>No potential conflict of interest relevant to this article was reported.</p>
        </fn>
      </author-notes>
      <abstract>
        <title>Abstract</title>
        <sec>
          <title>Background</title>
          <p> In spite of proven effectiveness of implantable cardioverter defibrillators (ICDs), shock therapy delivered by the device may result in increased levels of anxiety and depression, leading to deleterious effects on quality of life.</p>
        </sec>
        <sec>
          <title>Objective</title>
          <p> To carry out the translation, cross-cultural adaptation and validation of the <italic>Florida Shock Anxiety Scale</italic> (FSAS) scale into Brazilian Portuguese.</p>
        </sec>
        <sec>
          <title>Methods</title>
          <p> In this psychometric study, construct validity was performed by exploratory (EFA) and confirmatory (CFA) factor analyses, and by item response theory (IRT). The adjustment indexes of the CFA were: Robust Mean-Scaled Chi Square/df NNFI, CFI (Comparative Fit Index), GFI (Goodness Fit Index), AGFI (Adjusted Goodness Fit Index), RMSEA (Root Mean Square Error of Approximation) and RMSR (Root Mean Square of Residuals). Reliability was evaluated through Cronbach&#8217;s Alpha, McDonald&#8217;s Omega and Greatest Lower Bound (GLB). The analyses were carried out with the programs SPSS 23 and Factor 10.8.01. A 5 percent significance level was used.</p>
        </sec>
        <sec>
          <title>Results</title>
          <p> The final Portuguese version of the FSAS was administered to 151 ICD patients, with a mean age of 55.7 &#177; 14.1 years, and predominantly male. The parallel analysis indicated that the FSAS is unidimensional, with an explained variance of 64.4%. The correlations ranged from 0.31 to 0.77, factor loadings from 0.67 to 0.86, and communalities from 0.46 to 0.74. The adjustment indexes of the CFA were above the quality threshold. Satisfactory reliability evidence was provided by the FSAS.</p>
        </sec>
        <sec>
          <title>Conclusions</title>
          <p> The FSAS-Br showed consistent validity and reliability evidence. Therefore, it can be used in ICD patients in Brazil. (Arq Bras Cardiol. 2020; 114(5):764-772)</p>
        </sec>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>Implantable defibrillator</kwd>
        <kwd>Shock therapies</kwd>
        <kwd>Arrhythmias</kwd>
        <kwd>Anxiety</kwd>
        <kwd>Psychometric</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <sec sec-type="intro">
        <title>Introduction</title>
        <p>Nowadays, there are no doubts regarding the role of the implantable cardioverter defibrillator (ICD) for prevention of sudden cardiac death, especially among patients with ventricular dysfunction and arrhythmogenic genetic diseases.<sup><xref ref-type="bibr" rid="B1">1</xref>-<xref ref-type="bibr" rid="B3">3</xref></sup> Due to its proven efficacy in identifying and correcting potentially lethal ventricular tachyarrhythmias, the number of ICD implantations has increased significantly worldwide, and more than 250,000 procedures are performed every year.<sup><xref ref-type="bibr" rid="B4">4</xref></sup></p>
        <p>The primary purpose of ICD is to correct potentially fatal ventricular arrhythmias by delivering low- or high-energy therapy. Low-energy therapy, known as antitachycardia pacing or antitachycardia pacing (ATP), is a painless method. High-energy therapy delivers shocks of up to 40 J which, in spite of causing major discomfort, usually occur after the patient has lost consciousness, since they are applied about 15 seconds after the initiation of ventricular fibrillation or fast ventricular tachyarrhythmia. In undesirable situations, such as arrhythmias resistant to overstimulation, or in electrical storm, high-energy discharges can occur in awake patients.<sup><xref ref-type="bibr" rid="B3">3</xref>,<xref ref-type="bibr" rid="B5">5</xref>,<xref ref-type="bibr" rid="B6">6</xref></sup></p>
        <p>It is estimated that the chances of ICD patients will need appropriate electric shocks for primary prevention of sudden cardiac death varies between 2 and 15% per year.<sup><xref ref-type="bibr" rid="B5">5</xref>-<xref ref-type="bibr" rid="B8">8</xref></sup> On the other hand, when the ICD is used for secondary prevention, the incidence of shock therapies may vary between 35 and 53%, within the first year after implantation.<sup><xref ref-type="bibr" rid="B5">5</xref>-<xref ref-type="bibr" rid="B8">8</xref></sup> Despite the high level of technological sophistication of ICDs, unfortunately, there is the risk that the patient may receive inappropriate shock deliveries as a result of erroneous discrimination between supraventricular and ventricular tachyarrhythmias. On these occasions, the sensation reported is a painful and distressing experience.<sup><xref ref-type="bibr" rid="B9">9</xref>-<xref ref-type="bibr" rid="B14">14</xref></sup></p>
        <p>ICD patients live with the expectation that, at any moment, the device will deliver shock therapies to interrupt ventricular arrhythmias resulting from their heart disease. Thus, although they recognize the benefits of the treatment, some patients may present with anxiety, depression, mood disorders, post-traumatic stress disorder, as well as fear that the device will not operate in crucial situations.<sup><xref ref-type="bibr" rid="B9">9</xref>-<xref ref-type="bibr" rid="B14">14</xref></sup> On the other hand, ICD implantation has been reported to provide the patient with a great sense of safety, considering the device&#8217;s capacity to interrupt unexpected episodes of potentially fatal ventricular arrhythmias.<sup><xref ref-type="bibr" rid="B10">10</xref>-<xref ref-type="bibr" rid="B14">14</xref></sup></p>
        <p>In face of the concern about the deleterious effects of ICD on psychosocial adaptation, an scale was specifically developed to assess the level of anxiety related to the presence of ICD and to the shocks delivered by the device, for use both in clinical practice and in the context of scientific research.<sup><xref ref-type="bibr" rid="B15">15</xref>,<xref ref-type="bibr" rid="B16">16</xref></sup> The Florida Shock Anxiety Scale (FSAS) quickly achieved wide international acceptance, and has been translated and validated in several countries (Netherlands,<sup><xref ref-type="bibr" rid="B17">17</xref></sup> Denmark,<sup><xref ref-type="bibr" rid="B18">18</xref></sup>Poland,<sup><xref ref-type="bibr" rid="B19">19</xref></sup> China,<sup><xref ref-type="bibr" rid="B20">20</xref></sup> Norway,<sup><xref ref-type="bibr" rid="B21">21</xref></sup> Turkey<sup><xref ref-type="bibr" rid="B22">22</xref></sup>), with consistent results.</p>
      </sec>
      <sec>
        <title>Objectives</title>
        <p>The purpose of the present study was to assess the psychometric properties of the Brazilian version of the FSAS for ICD patients.</p>
      </sec>
      <sec sec-type="methods">
        <title>Methods</title>
        <sec>
          <title>Study design</title>
          <p>This study was conducted in a high-complexity cardiology hospital and it was approved by that hospital&#8217;s Committee of Ethics in Research. All subjects signed a free and informed consent form.</p>
          <sec>
            <title>Study location and ethical aspects</title>
            <p>This was a psychometric study of cross-cultural adaptation and validation of the FSAS.</p>
          </sec>
        </sec>
      </sec>
      <sec>
        <title>The Florida Shock Anxiety Scale (FSAS)</title>
        <p>The FSAS was developed in 2006 in the United States to provide a quantitative measure of ICD shock-related anxiety. The instrument consists of 10 items, with five response options (&#8220;not at all&#8221;,&#8221;rarely&#8221;,&#8221;some of the time&#8221;,&#8221;most of the time&#8221;,&#8221;all the time&#8221;), corresponding to a 5-point Likert scale.<sup><xref ref-type="bibr" rid="B15">15</xref>,<xref ref-type="bibr" rid="B16">16</xref></sup></p>
        <p>Questions are related to patients&#8217; fear or anxiety caused by the expectation that the device may deliver shock therapies and to the behavioral changes (not engaging in physical exercise or in sexual activity, or not getting angry or upset, for instance) to avoid the occurrence of ICD therapies.</p>
        <p>The FSAS total score is determined by the sum of all items, with a maximum score of 50 points. The higher the score, the higher the anxiety level. The items receiving three points or more should be considered the most critical aspects.<sup><xref ref-type="bibr" rid="B17">17</xref>,<xref ref-type="bibr" rid="B18">18</xref></sup>The instrument can be self-administered or administered by interview.</p>
      </sec>
      <sec>
        <title>Stage 1 &#8211; Translation and cross-cultural adaptation of the instrument</title>
        <p>The cross-cultural adaptation process of the FSAS followed international guidelines and included five stages: (1) Translation by two independent translators; (2) Synthesis of the translations; (3) Back-translation; (4) Harmonization of the translations by the expert committee; (5) Pretest with the target population; (6) Pretest review and final translation.<sup><xref ref-type="bibr" rid="B23">23</xref>-<xref ref-type="bibr" rid="B25">25</xref></sup>The expert committee was composed by professionals of the area of artificial cardiac stimulation and by nurses.</p>
        <p>The translation of the original instrument into Portuguese was performed by two independent Brazilian translators, proficient both in the Portuguese and English languages. In this stage, the translations produced by the two independent translators (T<sub>1</sub> and T<sub>2</sub>) were reconciled into one version (T<sub>1</sub>-<sub>2</sub>), after discussion with the expert committee. Working from the final version and blind to the original version, two bilingual teachers carried out the back-translations (RT<sub>1</sub> and RT<sub>2</sub>). The aim of this stage was to measure the semantic and idiomatic consistency of the translations produced in the first stage. Finally, a new meeting was held with the expert committee to review all the cross-cultural adaptation process and undertake the harmonization across versions, thus obtaining the pre-final version of the instrument (<xref ref-type="fig" rid="f01001">Figure 1</xref>).</p>
        <p>
          <fig id="f01001">
            <label>Figure 1</label>
            <caption>
              <title>&#8211; <italic>Cross-cultural adaptation process of the FSAS instrument</italic></title>
            </caption>
            <graphic xlink:href="1678-4170-abc-114-05-0764-90255-gf01-en.jpg"/></fig>
        </p>
        <p>The pretest version was administered in a convenience sample of 20 ICD patients, aged between 18 and 80 years, All patients were recruited during an outpatient cardiovascular clinic appointment, and were at least 6 months postimplant. The pretest was conducted to identify and correct possible translation problems. Following self-completion of the instrument, a clarifying interview was held to verify the existence of irrelevant or hardly understandable items, as well as to measure the understanding of each item of the instrument. It was established that the translation would be reviewed or reformulated if less than 80% of the participants were able to understand the items.</p>
      </sec>
      <sec>
        <title>Stage 2 &#8211; construct validation of the FSAS</title>
        <p>The final Portuguese version of the FSAS was administered to a convenience sample of 151 participants with the following characteristics: (1) adults, aged between 18 and 80 years, of both sexes and with any education level; (2) ICD implanted for more than 6 months; (3) capable of understanding and answering the questionnaire used in the study; (4) having agreed to participate in the study by signing the informed consent form. We did not include in the study patients presenting at least one of the following situations: (1) indication for cardiac transplantation; (2) ongoing pregnancy; (3) malignant neoplasia.</p>
        <p>Patients were selected consecutively, during outpatient care or by visits to the inpatient unit of our institution. Individuals who met the eligibility criteria were invited to answer the FSAS questionnaire. At the same time, demographic, clinical and ICD data were collected by using electronic case report forms developed in REDCap<sup><xref ref-type="bibr" rid="B26">26</xref></sup> (Research Electronic Data Capture) hosted at the hospital&#8217;s server.</p>
        <sec>
          <title>Sample size</title>
          <p>Sample size determination for psychometric studies is usually calculated based on the number of items of the instrument. Some studies have demonstrated that a ratio of 20:1 or greater, that is, 20 participants per item would be ideal. However, ratios of 10:1 are sufficient to allow for adequate analysis. Thus, a minimum sample number of 150 patients was established.<sup><xref ref-type="bibr" rid="B25">25</xref></sup></p>
        </sec>
      </sec>
      <sec>
        <title>Statistical Analysis</title>
        <sec>
          <title>Descriptive analysis</title>
          <p>Detailed descriptive analysis was performed, using measures of central tendency (mean, standard deviation, median, trimmed average, confidence intervals and interquartile interval). The Kolmogorov-Smirnov (KS) test was used to test the normality of each item in the questionnaire, whereas the Mardia test was employed to assess multivariate normality.</p>
          <p>All analyses were performed using SPSS 23 statistical package software and Factor 10.8.01, adopting a level of significance of 5%.</p>
        </sec>
        <sec>
          <title>Construct validity and dimensionality</title>
          <p>In this study, we conducted an exploratory factor analysis (EFA) and a confirmation factor analysis (CFA) to verify the dimensionality of the FSAS in its Portuguese version.</p>
          <p>The dimensionality testing was performed using Robust Parallel Analysis (RPA) through the Optimal implementation of Parallel Analysis (PA) with minimum rank factor analysis (MRFA), which minimizes the common variance of residuals.<sup><xref ref-type="bibr" rid="B27">27</xref>,<xref ref-type="bibr" rid="B28">28</xref></sup>The robustness of the test was determined from the association of a bootstrap with sample extrapolation to 5,000. Factor extraction was done initially with Robust Unweighted Least Squares (RULS), which reduces the matrix of residuals.<sup><xref ref-type="bibr" rid="B29">29</xref></sup></p>
        </sec>
        <sec>
          <title>Item Response Theory</title>
          <p>Item discrimination index was used (a), which measures the association strength between the item and the latent variable, and whose interpretation is similar to factor loading in the exploratory factor analysis.</p>
        </sec>
        <sec>
          <title>Quality parameters of the translated and adapted versions of the FSAS</title>
          <p>To adequate the items and the models, the following criteria were taken into account: the explained variance of the model (60 to 70%), factor loading values (&gt; 0.50), communalities (&gt; 0.40) and item discrimination, and collinearity and multicollinearity problems (factor loads ranging from 0.80 to 0.85).</p>
        </sec>
        <sec>
          <title>Indices of adjustment obtained in the Confirmatory Factor Analysis</title>
          <p>The model adjustment indices and their respective expected values were: Robust Mean-Scaled Chi Square/df NNFI (Non-Normed Fit Index &gt; 0.93), CFI (Comparative Fit Index &gt; 0.94), GFI (Goodness Fit Index &gt; 0.95), AGFI (Adjusted Goodness Fit Index &gt; 0.93), RMSEA (Root Mean Square Error of Approximation &lt; 0.07) and RMSR (Root Mean Square of Residuals &lt; 0.08).<sup><xref ref-type="bibr" rid="B29">29</xref>-<xref ref-type="bibr" rid="B31">31</xref></sup></p>
        </sec>
        <sec>
          <title>Reliability</title>
          <p>Three indicators were adopted to assess the reliability of the Brazilian version of the FSAS questionnaire: Coefficient Alpha (&#8220;Cronbach&#8217;s Alpha&#8221;), Omega and the Greatest Lower Bound (GLB).</p>
        </sec>
      </sec>
      <sec sec-type="results">
        <title>Results</title>
        <sec>
          <title>The final version of the FSAS</title>
          <p>The stages of the translation and cross-cultural adaptation resulted in similar versions of the FSAS instrument. The synthesis of the translations was quite concise and combined the most coherent elements of each translation. The back-translations confirmed the good quality of the translations and the synthesis process carried out in the initial stages.</p>
          <p>A total of 20 ICD patients, with a mean of age 55.6 &#177; 6.8 years, took part in the pretest. Of these, 50% were female, 50% were white and 30% had studied up to High School. All participants reported that the items were relevant, easy to understand and that the response options were clear. No modifications in the instrument were required. <xref ref-type="table" rid="t1001">Table 1</xref> shows the instrument items in its English and Portuguese versions.</p>
          <p>
            <table-wrap id="t1001">
              <label>Table 1</label>
              <caption>
                <title>&#8211; Original and Brazilian version of the Florida Shock Anxiety Scale (FSAS-Br) instrument</title>
              </caption>
              <table frame="hsides" rules="groups">
                <colgroup width="33%">
                  <col/>
                  <col/>
                  <col/>
                </colgroup>
                <thead>
                  <tr>
                    <th align="left">Item</th>
                    <th>Original Instrument</th>
                    <th>Brazilian version: FSAS-Br</th>
                  </tr>
                </thead>
                <tbody>
                  <tr>
                    <td>1</td>
                    <td align="center">I am scared to exercise because it may increase my heart rate and cause my device to fire.</td>
                    <td align="center">Eu tenho medo de fazer exerc&#237;cios f&#237;sicos porque isso pode aumentar meus batimentos card&#237;acos e fazer o meu CDI me aplicar um choque.</td>
                  </tr>
                  <tr>
                    <td>2</td>
                    <td align="center">I am afraid of being alone when the ICD fires and I need help.</td>
                    <td align="center">Eu tenho medo de estar sozinho e precisar de ajuda quando o CDI me aplicar um choque.</td>
                  </tr>
                  <tr>
                    <td>3</td>
                    <td align="center">I do not get angry or upset because it may cause my ICD to fire.</td>
                    <td align="center">Eu n&#227;o posso ficar nervoso ou chateado porque isso pode fazer o CDI me aplicar um choque.</td>
                  </tr>
                  <tr>
                    <td>4</td>
                    <td align="center">It bothers me that I do not know when the ICD will fire.</td>
                    <td align="center">Me sinto preocupado por n&#227;o saber quando o CDI vai me aplicar um choque.</td>
                  </tr>
                  <tr>
                    <td>5</td>
                    <td align="center">I worry about the ICD not firing sometime when it should.</td>
                    <td align="center">Eu me preocupo com a possibilidade do CDI n&#227;o funcionar quando eu precisar.</td>
                  </tr>
                  <tr>
                    <td>6</td>
                    <td align="center">I am afraid to touch others for fear I&#8217;ll shock them if the ICD fires.</td>
                    <td align="center">Eu tenho medo de tocar nas pessoas e dar um choque nelas caso o CDI dispare.</td>
                  </tr>
                  <tr>
                    <td>7</td>
                    <td align="center">I worry about the ICD firing and creating a scene.</td>
                    <td align="center">Eu me preocupo sobre a possibilidade de assustar as pessoas quando o CDI me aplicar um choque.</td>
                  </tr>
                  <tr>
                    <td>8</td>
                    <td align="center">When I notice my heart beating rapidly, I worry that the ICD will fire.</td>
                    <td align="center">Quando eu percebo que meu cora&#231;&#227;o bate mais r&#225;pido, eu fico preocupado que o CDI vai me aplicar um choque.</td>
                  </tr>
                  <tr>
                    <td>9</td>
                    <td align="center">I have unwanted thoughts of my ICD firing.</td>
                    <td align="center">Eu penso o tempo todo que a qualquer momento o CDI pode me aplicar um choque.</td>
                  </tr>
                  <tr>
                    <td>10</td>
                    <td align="center">I do not engage in sexual activities because it may cause my ICD to fire.</td>
                    <td align="center">Eu n&#227;o tenho rela&#231;&#245;es sexuais porque isso pode fazer o CDI me aplicar um choque.</td>
                  </tr>
                  <tr>
                    <td>
										</td>
                    <td align="center">Response options <list list-type="order"><list-item><p>Not at all</p></list-item><list-item><p>Rarely</p></list-item><list-item><p>Some of the time</p></list-item><list-item><p>Most of the time</p></list-item></list>
										</td>
                    <td align="center">Op&#231;&#245;es de resposta <list list-type="order"><list-item><p>Nunca</p></list-item><list-item><p>Quase nunca</p></list-item><list-item><p>Algumas vezes</p></list-item><list-item><p>Na maioria das vezes</p></list-item></list>
										</td>
                  </tr>
                </tbody>
              </table>
            </table-wrap>
          </p>
        </sec>
        <sec>
          <title>Psychometric properties of the FSAS</title>
          <sec>
            <title>Population composition</title>
            <p>In this stage of the study, 151 ICD patients, with a mean of 55.7&#177;14.1 years (range, 19- 80 years), were included. There was a male sex predominance, which corresponded to 64% of the cases. Most patients were white (85.4%) and 49% had attended Middle School (<xref ref-type="table" rid="t2001">Table 2</xref>).</p>
            <p>
              <table-wrap id="t2001">
                <label>Table 2</label>
                <caption>
                  <title>&#8211; Demographic and clinical profile of the study participants</title>
                </caption>
                <table frame="hsides" rules="groups">
                  <colgroup width="50%">
                    <col/>
                    <col/>
                  </colgroup>
                  <thead>
                    <tr>
                      <th align="left">Characteristics</th>
                      <th align="left" style="font-weight:normal">
											</th>
                    </tr>
                  </thead>
                  <tbody>
                    <tr>
                      <td>Male sex</td>
                      <td align="center">64.0%</td>
                    </tr>
                    <tr>
                      <td>Age (years)</td>
                      <td align="center">55.7 &#177; 14.1</td>
                    </tr>
                    <tr>
                      <td>White</td>
                      <td align="center">85.4%</td>
                    </tr>
                    <tr>
                      <td>
                        <bold>Education</bold>
                      </td>
                      <td>
											</td>
                    </tr>
                    <tr>
                      <td>Higher Education</td>
                      <td align="center">14.8%</td>
                    </tr>
                    <tr>
                      <td>High School</td>
                      <td align="center">34.9%</td>
                    </tr>
                    <tr>
                      <td>Middle School</td>
                      <td align="center">49.0%</td>
                    </tr>
                    <tr>
                      <td>Illiterate</td>
                      <td align="center">1.3%</td>
                    </tr>
                    <tr>
                      <td>
                        <bold>Marital Status</bold>
                      </td>
                      <td>
											</td>
                    </tr>
                    <tr>
                      <td>Married</td>
                      <td align="center">64.9%</td>
                    </tr>
                    <tr>
                      <td>Single</td>
                      <td align="center">14.6%</td>
                    </tr>
                    <tr>
                      <td>Divorced</td>
                      <td align="center">7.9%</td>
                    </tr>
                    <tr>
                      <td>Widow</td>
                      <td align="center">6.6%</td>
                    </tr>
                    <tr>
                      <td>Stable union</td>
                      <td align="center">6.0%</td>
                    </tr>
                    <tr>
                      <td>
                        <bold>Structural Heart Disease</bold>
                      </td>
                      <td>
											</td>
                    </tr>
                    <tr>
                      <td>Chagas Disease</td>
                      <td align="center">30.5%</td>
                    </tr>
                    <tr>
                      <td>Ischemic Cardiomyopathy</td>
                      <td align="center">25.2%</td>
                    </tr>
                    <tr>
                      <td>Hypertrophic Cardiomyopathy</td>
                      <td align="center">14.6%</td>
                    </tr>
                    <tr>
                      <td>Dilated Cardiomyopathy</td>
                      <td align="center">13.2%</td>
                    </tr>
                    <tr>
                      <td>Brugada syndrome</td>
                      <td align="center">4.6%</td>
                    </tr>
                    <tr>
                      <td>Congenital Long QT Syndrome</td>
                      <td align="center">3.3%</td>
                    </tr>
                    <tr>
                      <td>Right Ventricular Arrhythmogenic Dysplasia</td>
                      <td align="center">2.6%</td>
                    </tr>
                    <tr>
                      <td>Others</td>
                      <td align="center">5.9%</td>
                    </tr>
                    <tr>
                      <td>
                        <bold>New York Heart Association Functional Class</bold>
                      </td>
                      <td>
											</td>
                    </tr>
                    <tr>
                      <td>I</td>
                      <td align="center">37.1%</td>
                    </tr>
                    <tr>
                      <td>II</td>
                      <td align="center">47.7%</td>
                    </tr>
                    <tr>
                      <td>III</td>
                      <td align="center">11.3%</td>
                    </tr>
                    <tr>
                      <td>IV</td>
                      <td align="center">4.0%</td>
                    </tr>
                    <tr>
                      <td>Left Ventricular Ejection Fraction (Echocardiography)</td>
                      <td align="center">41.2 &#177; 15.6</td>
                    </tr>
                    <tr>
                      <td>
                        <bold>Comorbidities</bold>
                      </td>
                      <td>
											</td>
                    </tr>
                    <tr>
                      <td>None</td>
                      <td align="center">29.1%</td>
                    </tr>
                    <tr>
                      <td>Hypertension</td>
                      <td align="center">49.5%</td>
                    </tr>
                    <tr>
                      <td>Coronary Artery Disease</td>
                      <td align="center">15.9%</td>
                    </tr>
                    <tr>
                      <td>Diabetes</td>
                      <td align="center">20.6%</td>
                    </tr>
                    <tr>
                      <td>Atrial Fibrillation</td>
                      <td align="center">27.1%</td>
                    </tr>
                    <tr>
                      <td>Chronic Kidney Disease</td>
                      <td align="center">6.5%</td>
                    </tr>
                    <tr>
                      <td>Dislipidemia</td>
                      <td align="center">51.4%</td>
                    </tr>
                    <tr>
                      <td>Charlson comorbidity index</td>
                      <td align="center">1.3 &#177; 1.0</td>
                    </tr>
                    <tr>
                      <td>
                        <bold>Use of medication</bold>
                      </td>
                      <td>
											</td>
                    </tr>
                    <tr>
                      <td>ACEI/ARB</td>
                      <td align="center">72.7%</td>
                    </tr>
                    <tr>
                      <td>Beta blockers</td>
                      <td align="center">85.4%</td>
                    </tr>
                    <tr>
                      <td>Diuretics</td>
                      <td align="center">50.7%</td>
                    </tr>
                    <tr>
                      <td>Antiarrhythmic drugs</td>
                      <td align="center">58.9%</td>
                    </tr>
                    <tr>
                      <td>Platelet antiaggregants</td>
                      <td align="center">31.8%</td>
                    </tr>
                    <tr>
                      <td>Oral anticoagulants</td>
                      <td align="center">27.8%</td>
                    </tr>
                    <tr>
                      <td>
                        <bold>ICD indication</bold>
                      </td>
                      <td>
											</td>
                    </tr>
                    <tr>
                      <td>Primary prevention of sudden cardiac death</td>
                      <td align="center">19.9%</td>
                    </tr>
                    <tr>
                      <td>Secondary prevention of sudden cardiac death</td>
                      <td align="center">80.1%</td>
                    </tr>
                    <tr>
                      <td>
                        <bold>ICD Type</bold>
                      </td>
                      <td>
											</td>
                    </tr>
                    <tr>
                      <td>Ventricular ICD</td>
                      <td align="center">41.1%</td>
                    </tr>
                    <tr>
                      <td>Atrioventricular ICD</td>
                      <td align="center">46.4%</td>
                    </tr>
                    <tr>
                      <td>Cardiac resynchronization ICD</td>
                      <td align="center">12.6%</td>
                    </tr>
                    <tr>
                      <td>Time of ICD implantation (years)</td>
                      <td align="center">6.7 &#177; 4.4</td>
                    </tr>
                    <tr>
                      <td>
                        <bold>ICD therapies</bold>
                      </td>
                      <td>
											</td>
                    </tr>
                    <tr>
                      <td>Received shock therapies</td>
                      <td align="center">60.3%</td>
                    </tr>
                    <tr>
                      <td>Never received shock therapies</td>
                      <td align="center">39.7%</td>
                    </tr>
                  </tbody>
                </table>
                <table-wrap-foot>
                  <fn id="TFN1001">
                    <p>
                      <italic>ARB: angiotensin receptor blocker; ACEI: angiotensin-converting enzyme inhibitor.</italic>
                    </p>
                  </fn>
                </table-wrap-foot>
              </table-wrap>
            </p>
            <p>Among the cardiac diseases, there was a predominance of Chagas disease, which was present in 30.5% of the cases, followed by ischemic cardiomyopathy in 25.2%. Brugada syndrome and congenital long-QT syndrome (LQTS) were identified in 4.6 and 3.3% of patients, respectively.</p>
            <p>Baseline assessment showed that most patients were in the New York Heart Association (NYHA) functional classes I (37.1%) and II (47.7%). Left ventricular function was determined by bidimensional transthoracic echocardiography and ranged from 18 to 77%, with a median of 35%.</p>
            <p>Only 29.1% of the patients did not present any associated comorbidities. Dyslipidemia and arterial hypertension were the most frequent comorbidities, being present in 51.4% and 49.5% of patients, respectively. Atrial fibrillation was present in 27.1% of the individuals studied (<xref ref-type="table" rid="t2001">Table 2</xref>).</p>
            <p>As expected, 80.1% of the indications for ICD were r secondary prophylaxis of sudden cardiac death. In Brazil, due to lack of resources, ICD implantation is still underused for primary prophylaxis of sudden cardiac death.</p>
          </sec>
        </sec>
      </sec>
      <sec>
        <title>Descriptive analysis of the FSAS items</title>
        <p>Through descriptive analysis of the instrument items, it was possible to identify that normality of distribution was violated, indicating, therefore, the need for polychoric correlation, instead of Pearson&#8217;s correlation coefficient.</p>
        <p>The means of the instrument items ranged from 1.5 to 2.9. The FSAS average score was 22.8 &#177; 11.1, with a median of 20 points and variation of 10 to 50 points. There was no impact of extreme values on the mean (<xref ref-type="table" rid="t3001">Table 3</xref>).</p>
        <p>
          <table-wrap id="t3001">
            <label>Table 3</label>
            <caption>
              <title>&#8211; Descriptive analysis of the FSAS-Br items</title>
            </caption>
            <table frame="hsides" rules="groups">
              <colgroup width="8%">
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
                <col/>
              </colgroup>
              <thead>
                <tr>
                  <th align="left">Item</th>
                  <th>Average</th>
                  <th>SD</th>
                  <th>Inferior threshold</th>
                  <th>Superior threshold</th>
                  <th>5 % trimmed average</th>
                  <th>Median</th>
                  <th>Range</th>
                  <th>IQR</th>
                  <th>Asymmetry</th>
                  <th>Kurtosis</th>
                  <th>KS</th>
                  <th>Sig.</th>
                </tr>
              </thead>
              <tbody>
                <tr>
                  <td>1</td>
                  <td align="center">2.95</td>
                  <td align="center">1.86</td>
                  <td align="center">2.66</td>
                  <td align="center">3.25</td>
                  <td align="center">2.95</td>
                  <td align="center">3.00</td>
                  <td align="center">4.00</td>
                  <td align="center">4.00</td>
                  <td align="center">0.12</td>
                  <td align="center">-4.80</td>
                  <td align="center">0.29</td>
                  <td align="center">0.01</td>
                </tr>
                <tr>
                  <td>2</td>
                  <td align="center">2.46</td>
                  <td align="center">1.72</td>
                  <td align="center">2.19</td>
                  <td align="center">2.74</td>
                  <td align="center">2.40</td>
                  <td align="center">1.00</td>
                  <td align="center">4.00</td>
                  <td align="center">4.00</td>
                  <td align="center">2.84</td>
                  <td align="center">-3.67</td>
                  <td align="center">0.33</td>
                  <td align="center">0.01</td>
                </tr>
                <tr>
                  <td>3</td>
                  <td align="center">2.26</td>
                  <td align="center">1.69</td>
                  <td align="center">1,99</td>
                  <td align="center">2,53</td>
                  <td align="center">2,18</td>
                  <td align="center">1,00</td>
                  <td align="center">4,00</td>
                  <td align="center">3,00</td>
                  <td align="center">4,06</td>
                  <td align="center">-2,90</td>
                  <td align="center">0,37</td>
                  <td align="center">0,01</td>
                </tr>
                <tr>
                  <td>4</td>
                  <td align="center">2,47</td>
                  <td align="center">1,69</td>
                  <td align="center">2,20</td>
                  <td align="center">2,74</td>
                  <td align="center">2,41</td>
                  <td align="center">1,00</td>
                  <td align="center">4,00</td>
                  <td align="center">3,00</td>
                  <td align="center">2,63</td>
                  <td align="center">-3,69</td>
                  <td align="center">0,33</td>
                  <td align="center">0,01</td>
                </tr>
                <tr>
                  <td>5</td>
                  <td align="center">2,43</td>
                  <td align="center">1,62</td>
                  <td align="center">2,17</td>
                  <td align="center">2,69</td>
                  <td align="center">2,37</td>
                  <td align="center">2,00</td>
                  <td align="center">4.00</td>
                  <td align="center">3.00</td>
                  <td align="center">2.97</td>
                  <td align="center">-3.21</td>
                  <td align="center">0.30</td>
                  <td align="center">0.01</td>
                </tr>
                <tr>
                  <td>6</td>
                  <td align="center">1.54</td>
                  <td align="center">1.25</td>
                  <td align="center">1.34</td>
                  <td align="center">1.74</td>
                  <td align="center">1.38</td>
                  <td align="center">1.00</td>
                  <td align="center">4.00</td>
                  <td align="center">0.00</td>
                  <td align="center">10.81</td>
                  <td align="center">7.67</td>
                  <td align="center">0.48</td>
                  <td align="center">0.01</td>
                </tr>
                <tr>
                  <td>7</td>
                  <td align="center">2.36</td>
                  <td align="center">1.68</td>
                  <td align="center">2.09</td>
                  <td align="center">2.63</td>
                  <td align="center">2.29</td>
                  <td align="center">1.00</td>
                  <td align="center">4.00</td>
                  <td align="center">3.00</td>
                  <td align="center">3.34</td>
                  <td align="center">-3.30</td>
                  <td align="center">0.34</td>
                  <td align="center">0.01</td>
                </tr>
                <tr>
                  <td>8</td>
                  <td align="center">2.74</td>
                  <td align="center">1.72</td>
                  <td align="center">2.47</td>
                  <td align="center">3.02</td>
                  <td align="center">2.71</td>
                  <td align="center">3.00</td>
                  <td align="center">4.00</td>
                  <td align="center">4.00</td>
                  <td align="center">1.30</td>
                  <td align="center">-4.14</td>
                  <td align="center">0.28</td>
                  <td align="center">0.01</td>
                </tr>
                <tr>
                  <td>9</td>
                  <td align="center">2.07</td>
                  <td align="center">1.59</td>
                  <td align="center">1.81</td>
                  <td align="center">2.32</td>
                  <td align="center">1.96</td>
                  <td align="center">1.00</td>
                  <td align="center">4.00</td>
                  <td align="center">2.00</td>
                  <td align="center">5.37</td>
                  <td align="center">-1.56</td>
                  <td align="center">0.39</td>
                  <td align="center">0.01</td>
                </tr>
                <tr>
                  <td>10</td>
                  <td align="center">1.54</td>
                  <td align="center">1.24</td>
                  <td align="center">1.34</td>
                  <td align="center">1.74</td>
                  <td align="center">1.37</td>
                  <td align="center">1.00</td>
                  <td align="center">4.00</td>
                  <td align="center">0.00</td>
                  <td align="center">10.87</td>
                  <td align="center">7.84</td>
                  <td align="center">0.49</td>
                  <td align="center">0.01</td>
                </tr>
              </tbody>
            </table>
          </table-wrap>
        </p>
      </sec>
      <sec>
        <title>Construct validity and dimensionality of the FSAS</title>
        <p>The values obtained from the Kaiser-Meyer-Olkin index (KMO= 0.88), the Bartlett&#8217;s sphericity test (X<sup>2</sup>= 565.5, df= 45; p&lt;0.001) and the matrix determinant (0.0206 (p&lt;0.0001)) revealed a significant correlation between the items, which confirmed the adequacy of the EFA.</p>
        <p>The parallel analysis indicated the existence of only one dimension for the instrument. Moreover, this item set can explain 64.4% of latent variable (above the values recommended in the literature).<sup><xref ref-type="bibr" rid="B29">29</xref>-<xref ref-type="bibr" rid="B31">31</xref></sup> The eigenvalue criteria also indicated only one dimension, with a an eigenvalue of of 6.08. The fact that the instrument was unidimensional waived requirements for methods of matrix factor rotation. Unidimensionality indicated the use of the normal-ogive graded response IRT model, which is more adequate for a unidimensional polytomous model.<sup><xref ref-type="bibr" rid="B31">31</xref></sup></p>
        <p><xref ref-type="table" rid="t4001">Table 4</xref> presents the factor loads, which ranged from 0.67 to 0.86, representing excellent levels of adherence of the items to the latent variable, greater than the minimum criterion of 0.50, with no evidence of multicollinearity. The unidimensionality ruled out the possibility of cross-loading. Communalities varied between 0.46 and 0.74, with all the items above the threshold of 0.40. For item discrimination (a), the values ranged from 0.91 to 1.71, also indicating good adherence to the latent variable and corroborating the data obtained from factor loading.</p>
        <p>
          <table-wrap id="t4001">
            <label>Table 4</label>
            <caption>
              <title>&#8211; Construct validity of the FSAS-Br: factor loading, communalities and item description</title>
            </caption>
            <table frame="hsides" rules="groups">
              <colgroup width="25%">
                <col/>
                <col/>
                <col/>
                <col/>
              </colgroup>
              <thead>
                <tr>
                  <th align="left">Item</th>
                  <th>Factor loading</th>
                  <th style="font-weight:normal">Communalities (h<sup>2</sup>)</th>
                  <th>Item description (a)</th>
                </tr>
              </thead>
              <tbody>
                <tr>
                  <td>1</td>
                  <td align="center">0.76</td>
                  <td align="center">0.58</td>
                  <td align="center">1.17</td>
                </tr>
                <tr>
                  <td>2</td>
                  <td align="center">0.77</td>
                  <td align="center">0.60</td>
                  <td align="center">1.22</td>
                </tr>
                <tr>
                  <td>3</td>
                  <td align="center">0.76</td>
                  <td align="center">0.59</td>
                  <td align="center">1.19</td>
                </tr>
                <tr>
                  <td>4</td>
                  <td align="center">0.81</td>
                  <td align="center">0.65</td>
                  <td align="center">1.37</td>
                </tr>
                <tr>
                  <td>5</td>
                  <td align="center">0.68</td>
                  <td align="center">0.46</td>
                  <td align="center">0.93</td>
                </tr>
                <tr>
                  <td>6</td>
                  <td align="center">0.71</td>
                  <td align="center">0.50</td>
                  <td align="center">1.00</td>
                </tr>
                <tr>
                  <td>7</td>
                  <td align="center">0.67</td>
                  <td align="center">0.46</td>
                  <td align="center">0.91</td>
                </tr>
                <tr>
                  <td>8</td>
                  <td align="center">0.73</td>
                  <td align="center">0.53</td>
                  <td align="center">1.05</td>
                </tr>
                <tr>
                  <td>9</td>
                  <td align="center">0.86</td>
                  <td align="center">0.74</td>
                  <td align="center">1.71</td>
                </tr>
                <tr>
                  <td>10</td>
                  <td align="center">0.74</td>
                  <td align="center">0.55</td>
                  <td align="center">1.11</td>
                </tr>
              </tbody>
            </table>
          </table-wrap>
        </p>
        <p>The CFA revealed good adjustment to the unidimensional model, with values similar to those recommended by the literature: Robust Mean and Variance-Adjusted Chi Square X<sup>2</sup>/ df (35) = 40.40; p &lt; 0.243; NNFI= 0.997; CFI= 0,997; GFI= 0.986; AGFI= 0.982. The residual indicators were at good levels (RMSEA= 0.032; RMSR= 0.077), showing little difference between the original matrix and the matrix generated from factor loadings.<sup><xref ref-type="bibr" rid="B31">31</xref></sup></p>
      </sec>
      <sec>
        <title>Reliability of the FSAS-Br</title>
        <p>Satisfactory reliability evidence was provided by the FSAS-Br scale, with a Cronbach&#8217;s alpha coefficient of 0.92, a McDonald&#8217;s Omega coefficient of 0.92 and GLB of 0.98.</p>
      </sec>
      <sec sec-type="discussion">
        <title>Discussion</title>
        <p>In the present study, we described the translation and cross-cultural adaptation process of a brief scale designed to provide a quantitative measure of ICD shock-related anxiety, folllowing international methodological standards.<sup><xref ref-type="bibr" rid="B23">23</xref>-<xref ref-type="bibr" rid="B25">25</xref></sup> The final translation of the FSAS into Brazilian Portuguese (FSAS-Br) presented conceptual, semantic, cultural and measurement equivalences compared to the original items in English.<sup><xref ref-type="bibr" rid="B15">15</xref>,<xref ref-type="bibr" rid="B16">16</xref></sup></p>
        <p>Efforts were made to include patients with different sociodemographic profiles and various types of underlying heart diseases to ensure heterogeneous representation, aiming at providing the best calibration of the items. Thus, patients with different ICD types (ventricular, atrioventricular or associated with cardiac resynchronization therapy) were included, as well as patients with indications for primary or secondary prophylaxis of sudden cardiac death. Notwithstanding, the most common kinds of heart disease among these patients&#8217; profiles have also been contemplated, with expressive prevalence of Chagas Disease, ischemic and hypertrophic cardiomyopathy.</p>
        <p>In the international scenario, the FSAS scale has been widely used in different scenarios, since it presents good sensitivity to identify the level of ICD shock-related anxiety and requires reduced time for completion.<sup><xref ref-type="bibr" rid="B15">15</xref>-<xref ref-type="bibr" rid="B22">22</xref></sup> Thus, it is important to highlight that the FSAS was not designed to assess relevant aspects of adaptation to the device and its real impact on quality of life, which makes it necessary to use other instruments to complement the assessment of these patients. In this sense, the authors who had created the FSAS developed another instrument, the Florida Patient Acceptance Survey (FPAS),<sup><xref ref-type="bibr" rid="B32">32</xref></sup> which aims at assessing the psychosocial adjustment of ICD patients. The results of the cross-cultural adaptation and validation process of the FPAS into Portuguese will be published in due course.</p>
        <p>Evidence of validity of an instrument has been recommended by the scientific community as a way to check whether the instrument actually and accurately measures the latent variable of interest. In addition, it is important to analyze whether the instrument factor structure is adequately represented by its dimensionality, that is, the number of dimensions that make up the instrument of assessment.<sup><xref ref-type="bibr" rid="B27">27</xref>-<xref ref-type="bibr" rid="B31">31</xref></sup> In the original publication of the FSAS, the authors claim that the instrument was bidimensional, presenting two dimensions: Consequence (composed of 7 items) and Trigger (composed of 3 items).<sup><xref ref-type="bibr" rid="B15">15</xref></sup>This model was not reproducible to the Brazilian version, because all analyses performed in this study supported the FSAS-Br scale unidimensionality. Revisiting the study by Kuhl et at.,<sup><xref ref-type="bibr" rid="B15">15</xref></sup> it is important to highlight that the sample was constituted by only 72 participants, which may have had an impact on the results of the psychometric analyses.</p>
        <p>Afterwards, the psychometric properties of the FSAS were evaluated, with a sample of 443 participants.<sup><xref ref-type="bibr" rid="B16">16</xref></sup> The CFA showed that the two previously identified dimensions were highly related to a second-order factor (&#8220;Shock anxiety&#8221;). In other words, the two dimensions identified previously could have been better explained by their association to a common factor, namely the &#8220;shock-related anxiety&#8221; dimension. Due to these results, the authors recommended that the total scale score may be more clinically useful, instead of subdividing it into the two dimensios described before. These results corroborate the factor structure identified in our study.</p>
        <p>Reliability assessment of the FSAS-Br scale revealed the accuracy of the Brazilian version, which was confirmed by adequate values of Cronbach&#8217;s alpha, McDonald&#8217;s Omega and GLB. The adoption of these three indications aimed to increase the accuracy of interpretation, since the Cronbach&#8217;s coefficient alpha is affected by the nature of data distribution and by sample size. Besides, its values may be increased by extensive scales, parallel and/or redundant elements or limited coverage of the construct under analysis, decreasing the reliability of the measurement.<sup><xref ref-type="bibr" rid="B33">33</xref></sup></p>
        <p>In general, the results observed in the present study showed that the instrument is reliable and valid for application in Brazil, meeting the quality requirements for patient-reported outcome measurements.</p>
        <sec>
          <title>Study limitations</title>
          <p>Although the population studied is larger than the samples of several other studies which have used the FSAS, further studies with more robust samples are crucial for the consolidation of its validity and for attesting its stability in the various possible scenarios and profiles of ICD patients.</p>
          <p>Further studies, evaluating the association of the FSAS-Br scores with the occurrence of ICD shock therapies and other clinic parameters will be useful to identify factors which may be associated with increased anxiety levels and, therefore, allow for the establishment of specific and personalized interventions for these patients.</p>
        </sec>
      </sec>
      <sec sec-type="conclusions">
        <title>Conclusions</title>
        <p>The FSAS-Br instrument presented consistent validity and reliability evidence and, therefore, its use can be recommended for the ICD population in Brazil, both in clinical practice and in scientific research.</p>
      </sec>
    </body>
    <back>
      <fn-group>
        <fn fn-type="other">
          <p>Study Association</p>
          <p>This study is not associated with any thesis or dissertation.</p>
        </fn>
        <fn fn-type="other">
          <p>Ethics approval and consent to participate</p>
          <p>This study was approved by the Ethics Committee of the CAPPesq under the protocol number CAAE:54522516.2.000.0068. All the procedures in this study were in accordance with the 1975 Helsinki Declaration, updated in 2013. Informed consent was obtained from all participants included in the study.</p>
        </fn>
      </fn-group>
      <fn-group>
        <fn fn-type="financial-disclosure">
          <p>Sources of Funding</p>
          <p>This study was funded by FAPESP. (Grant # 2016/02104-6).</p>
        </fn>
      </fn-group>
    </back>
  </sub-article>
</article>