<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="case-report" dtd-version="1.0" specific-use="sps-1.6" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="nlm-ta">Arq Bras Cardiol</journal-id>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">TQT6XYbRYXgRjRQr9KtGX5q</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2017001400491</article-id>
      <article-id pub-id-type="doi">10.5935/abc.20170118</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Case Report</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Combined Mitral and Aortic Valvar Bioprosthesis Transcatheter Transapical Implant: First Description in Brazil</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Sampaio</surname>
            <given-names>Roney Orismar</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <xref ref-type="corresp" rid="c1"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Paix&#227;o</surname>
            <given-names>Milena Ribeiro</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Miranda</surname>
            <given-names>Thais Taveira</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Veronese</surname>
            <given-names>Elinthon Tavares</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Palma</surname>
            <given-names>Jos&#233; Hon&#243;rio de Almeida</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Tarasoutchi</surname>
            <given-names>Fl&#225;vio</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
        </contrib>
        <aff id="aff1">
          <institution content-type="orgname">Universidade de S&#227;o Paulo</institution>
          <institution content-type="orgdiv1">Faculdade de Medicina</institution>
          <institution content-type="orgdiv2">Instituto do Cora&#231;&#227;o (InCor)</institution>
          <addr-line>
            <named-content content-type="city">S&#227;o Paulo</named-content>
            <named-content content-type="state">SP</named-content>
          </addr-line>
          <country country="BR">Brazil</country>
          <institution content-type="original">Instituto do Cora&#231;&#227;o (InCor) - Faculdade de Medicina da Universidade de S&#227;o Paulo, S&#227;o Paulo, SP - Brazil</institution>
          <institution content-type="normalized">Universidade de S&#227;o Paulo</institution>
        </aff>
      </contrib-group>
      <author-notes>
        <corresp id="c1"><bold>Mailing Address: Roney Orismar Sampaio</bold> Rua Comandante Garcia d`Avila, 412. Postal Code 05654-040. Morumbi, SP - Brazil. E-mail: <email>orismar@cardiol.br</email>, <email>sampaioroney@yahoo.com.br</email>
				</corresp>
        <fn fn-type="con">
          <p>
            <bold>Author contributions</bold>
          </p>
          <p>Conception and design of the research, Obtaining funding and Critical revision of the manuscript for intellectual content: Sampaio RO, Paix&#227;o MR, Fonseca JHAP, Tarasoutchi F; Acquisition of data and Analysis and interpretation of the data: Sampaio RO, Paix&#227;o MR, Miranda TT, Veronese ET, Fonseca JHAP; Statistical analysis: Sampaio RO, Paix&#227;o MR; Writing of the manuscript: Sampaio RO, Paix&#227;o MR, Miranda TT, Tarasoutchi F.</p>
        </fn>
        <fn fn-type="conflict">
          <p>
            <bold>Potential Conflict of Interest</bold>
          </p>
          <p>No potential conflict of interest relevant to this article was reported.</p>
        </fn>
      </author-notes>
      <pub-date pub-type="epub-ppub">
        <month>11</month>
        <year>2017</year>
      </pub-date>
      <volume>109</volume>
      <issue>5</issue>
      <fpage>491</fpage>
      <lpage>494</lpage>
      <history>
        <date date-type="received">
          <day>22</day>
          <month>02</month>
          <year>2016</year>
        </date>
        <date date-type="rev-recd">
          <day>21</day>
          <month>04</month>
          <year>2016</year>
        </date>
        <date date-type="accepted">
          <day>16</day>
          <month>08</month>
          <year>2016</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/" xml:lang="en">
          <license-p>This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
        </license>
      </permissions>
      <kwd-group xml:lang="en">
        <title>Keywords</title>
        <kwd>Transcatheter Aortic Valve Replacement</kwd>
        <kwd>Heart Valve Prosthesis Implantation</kwd>
        <kwd>Heart Valve Prosthesis</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec sec-type="intro">
      <title>Introduction</title>
      <p>From the earliest days of the heart surgery, the valves, when the reparation was not possible, were replaced by prosthetics using cardiopulmonary bypass. The good results of these procedures are well known. In the recent years, minimally invasive alternatives have been developed, aiming to make possible the treatment of individuals under high risk of complications and death caused by the conventional procedure. In 2002, the first transcatheter valvar implantation was made, which revolutionized the treatment of severe aortic stenosis. The equipment, techniques and skills have progressively evolved since then. More recently, from 2009, transcatheter mitral valvar implants for treatment of the prosthesis dysfunction (valve-in-valve) started to be performed. Currently, the transcatheter valvar implantation is one of the fields of greater development in cardiology.</p>
    </sec>
    <sec sec-type="cases">
      <title>Case Report</title>
      <p>A male patient aged 72 was admitted to the emergency room with congestive heart failure of progressive worsening. He presented a history of rheumatic fever, coronary artery disease, atrial fibrillation, chronic renal failure (creatinine clearance of 58 mL/min/1,72 m<sup>2</sup>) and amaurosis secondary to the macular degeneration of the retina. He underwent two previous cardiac surgical procedures: mitral valvuloplasty and coronary artery bypass grafting in 1993 and mitral valve replacement by bioprosthesis and new myocardial revascularization in 1998. There was a great technical difficulty in the last procedure, due to multiple adhesions.</p>
      <p>Upon physical examination at the entrance, he presented BP = 120/70 mmHg, HR = 60 bpm, irregular. Cardiac auscultation: hyperphonetic first heart sound, crescendo/decrescendo systolic murmur 5+/6+ in an aortic focus and holosystolic regurgitating murmur 3+/6+ in a mitral focus. The rest of the physical examination went without particularities.</p>
      <p>An echocardiography was performed, which showed a left atrium of 74 mm, diastolic diameter of the left ventricle of 52 mm and systolic diameter of 32 mm, thickness of the septum and posterior wall of 15 mm, systolic pulmonary artery pressure of 53 mmHg and ejection fraction of 77%. The mitral bioprosthesis was calcified with average LA/LV gradient of 13 mmHg, area of 1.7 cm<sup>2</sup> and important reflux. The aortic valve was calcified, with important stenosis (peak transvalvar gradient of 104 mmHg and average of 62 mmHg, valve area of 0.67 cm<sup>2</sup>) and discreet reflux.</p>
      <p>The cineangiocoronariography identified saphenous vein graft to the occluded right coronary artery, mammary artery to the anterior pervious descending, and multiple lesions in the native beds of the right coronary and left anterior descending arteries.</p>
      <p>The thoracic angiotomography showed valve calcium score of 3580 agatston and important coronary atheromatosis and ascending aorta (<xref ref-type="fig" rid="f1">Figure 1</xref>).</p>
      <p>
        <fig id="f1">
          <label>Figure 1</label>
          <caption>
            <title>Computed thoracic tomography showing intense calcification of the ascending aorta (A), aortic valve (B) and sinotubular junction (C). Measurements of the valve diameter (A) used to define the size of the prosthesis and of the sinotubular junction (B).</title>
          </caption>
          <graphic xlink:href="1678-4170-abc-109-05-0491-70118-gf01.jpg"/></fig>
      </p>
      <p>There were no acute compensating factors for heart failure, except for congestion attributed to the aortic and mitral valvar disease. The surgical risk by EuroSCORE II was of 13.23%. Due to the high surgical risk and technical difficulties reported in the last surgery, a discussion was held by the "Heart Team", and they opted for the valvar double percutaneous treatment through transapical transcatheter implant and approach of the coronary lesions retrospectively, prioritizing the resolution of the hemodynamic condition of the patient.</p>
      <p>On September 2015, the implantation of the aortic bioprosthesis and, after, of the mitral bioprosthesis were performed, both Inovare-Braile, numbers 28 and 30, respectively (<xref ref-type="fig" rid="f2">Figure 2</xref>). The procedure occurred without complications. On the third post-operatory day, piperacillin and tazobactam were started, for the treatment of nosocomial pneumonia. He presented plateletopenia (up to 30,000/mm<sup>3</sup>), worsening of the acute renal insufficiency and moderate pericardial effusion, quickly reversed with the use of corticosteroids and usual clinical measures. Following clinical stabilization, the patient was discharged. The three-dimensional echocardiography after the discharge presented well-placed prosthesis, without significant periprosthetic reflux in the valve in the aortic position, peak LA/LV gradient 24 mmHg and average of 14 mmHg. On the mitral position, a moderate periprosthetic reflux was observed, average LA/LV gradient of 9mmHg, mitral area 1.5 cm<sup>2</sup>, SPAP 46 mmHg. There was clinical improvement for functional class II.</p>
      <p>
        <fig id="f2">
          <label>Figure 2</label>
          <caption>
            <title>Radioscopy image showing Inovare-Braile bioprosthesis in aortic position no. 28 already implanted (A) and in mitral position no. 30, immediately after the implant (B). The sheath with guidewire for implantation of the mitral prosthesis (C), transvenous pacemaker electrode (D), transducer of the transesophageal echocardiography (E), pigtail catheter in the ascending aorta (F) and prior sternotomy wires (G) are observed.</title>
          </caption>
          <graphic xlink:href="1678-4170-abc-109-05-0491-70118-gf02.jpg"/></fig>
      </p>
    </sec>
    <sec sec-type="discussion">
      <title>Discussion</title>
      <p>The dysfunction of the valvar bioprosthesis may be secondary to the degeneration of the leaflets due to wear, calcification or rupture, as well as the formation of <italic>pannus</italic> (host tissue), thrombus or perivalvular leak. The durability is smaller when in the mitral position, in young individuals, in the presence of prosthetic mismatch, renal failure and hyperparathyroidism.<xref ref-type="bibr" rid="B1">1</xref><sup>,</sup><xref ref-type="bibr" rid="B2">2</xref>
			</p>
      <p>The increase in the use of biological prosthesis, associated to the increase of survival of operated individuals, have made surgical rapprochement increasingly common. The valve replacement surgery is, to this moment, the procedure of choice in cases of graft dysfunction, and it is associated to higher morbidity and mortality in relation to the first intervention. The technical difficulties of the surgical rapprochement may imply in longer period of cardiopulmonary bypass, need for transfusional support, and diaphragmatic paralysis by phrenic nerve injury, prolonged vasoplegia, aorto-coronary graft injury and increased risk of death.<xref ref-type="bibr" rid="B1">1</xref><sup>,</sup><xref ref-type="bibr" rid="B2">2</xref>
			</p>
      <p>The predictors of higher risk of complication are: advanced age, cognitive dysfunction, peripheral vascular disease, chronic lung disease, renal failure, functional class IV heart failure by the New York Heart Association (NYHA), ventricular dysfunction, combined procedures, number of rapprochement, mitral valve replacement, emergency surgery, shock in the preoperative period, stent thrombosis, the presence of endocarditis and paravalvular abscess.<xref ref-type="bibr" rid="B1">1</xref><sup>,</sup><xref ref-type="bibr" rid="B2">2</xref>
			</p>
      <p>The most used cardiac surgical risk scores in the daily practice are the STS and the EuroSCORE II. The former does not contemplate the risk calculation for double valvar replacement, as in the case at hand. The risk estimated by the EuroSCORE II was of 13.23%, indicating high risk of death.</p>
      <p>One of the alternatives to the conventional aortic valvar surgery for individuals of high surgical risk is the transcatheter implant, known as Transcatheter Aortic Valve Implantation (TAVI), which is being performed since 2002.<xref ref-type="bibr" rid="B3">3</xref> Since then, over 50,000 devices have been implanted throughout the world, with clinical outcomes that are similar to the surgery for patients with high or prohibitive surgical risk.<xref ref-type="bibr" rid="B1">1</xref> The bioprosthesis may be expandable by balloon or self-expanding, both dependent on the presence of aortic valve calcification to prevent its displacement, however, with higher risk of perivalvar regurgitation in cases of extreme calcification.</p>
      <p>The two most common pathways for the TAVI are transfemoral and transapical - a technique started in 2006, with access through minithoracotomy without the need for extracorporeal circulation. Although the transapical technique is more invasive, the advantages over the femoral pathway are: greater ease of valve implantation due to the proximity of the valve annulus of the cardiac apex, less manipulation of the aorta and peripheral arterial system reducing vascular complications and stroke.<xref ref-type="bibr" rid="B1">1</xref><sup>,</sup><xref ref-type="bibr" rid="B4">4</xref> There is no impediment to the use of this technique in patients with previous myocardial revascularization.</p>
      <p>The progress in the techniques and materials for transcatheter valve implantation in native valves allowed the strategy to be adapted for the treatment of dysfunction of biological prostheses, a technique called valve-in-valve. The aortic valve-in-valve procedures were the first to be performed, expanding the use of equipment and skills idealized for the TAVI. Since then, procedures with balloon-expansible and self-expansible prosthesis have been performed. Soon after, the method was expanded for mitral, pulmonary and tricuspid interventions.<xref ref-type="bibr" rid="B1">1</xref><sup>,</sup><xref ref-type="bibr" rid="B5">5</xref><sup>,</sup><xref ref-type="bibr" rid="B6">6</xref>
			</p>
      <p>The first mitral valve-in-valve procedures were performed in 2009, initially, with balloon-expansible prosthesis and, after, also with self-expansible prosthesis. From 2011, implants over the post annuloplasty valve annulus began to be performed, known as valve-in-ring. Most recently, from 2014, the mitral transcatheter interventions on native valves began.<xref ref-type="bibr" rid="B1">1</xref><sup>,</sup><xref ref-type="bibr" rid="B7">7</xref>
			</p>
      <p>Lastly, combined transcatheter procedures have been reported in the last few years.<xref ref-type="bibr" rid="B8">8</xref><sup>-</sup><xref ref-type="bibr" rid="B10">10</xref> It is a treatment that requires further investigation, exclusively proposed in cases where the conventional surgical procedure is prohibitive. We suggest a multidisciplinary discussion with a "Heart Team" for each patient, aiming to design the best type of intervention individually and cautiously.</p>
    </sec>
    <sec sec-type="conclusions">
      <title>Conclusion</title>
      <p>There are few reports of combined intervention in disorders of aortic and mitral valves.<xref ref-type="bibr" rid="B8">8</xref><sup>-</sup><xref ref-type="bibr" rid="B10">10</xref> This case was the first performed in Brazil with the implantation of the Inovare Braile national prosthesis, showing the huge potential for future interventions in selected patients.</p>
    </sec>
  </body>
  <back>
    <fn-group>
      <fn fn-type="financial-disclosure">
        <p>
          <bold>Sources of Funding</bold>
        </p>
        <p>There were no external funding sources for this study.</p>
      </fn>
      <fn fn-type="other">
        <p>
          <bold>Study Association</bold>
        </p>
        <p>This study is not associated with any thesis or dissertation work.</p>
      </fn>
    </fn-group>
    <ref-list>
      <title>References</title>
      <ref id="B1">
        <label>1</label>
        <mixed-citation>1 Paradis JM, Del Trigo M, Puri R, Rod&#233;s-Cabau J. Transcatheter valve-in-valve and valve-in-ring for treating aortic and mitral surgical prosthetic dysfunction. J Am Coll Cardiol. 2015;66(18):2019-37.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Paradis</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Del Trigo</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Puri</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Rod&#233;s-Cabau</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>Transcatheter valve-in-valve and valve-in-ring for treating aortic and mitral surgical prosthetic dysfunction</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2015</year>
          <volume>66</volume>
          <issue>18</issue>
          <fpage>2019</fpage>
          <lpage>2037</lpage>
        </element-citation>
      </ref>
      <ref id="B2">
        <label>2</label>
        <mixed-citation>2 Jones JM, O'kane H, Gladstone DJ, Sarsam MA, Campalani G, MacGowan SW, et al. Repeat heart valve surgery: risk factors for operative mortality. J Thorac Cardiovasc Surg. 2001;122(5):913-8.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Jones</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>O'kane</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Gladstone</surname>
              <given-names>DJ</given-names>
            </name>
            <name>
              <surname>Sarsam</surname>
              <given-names>MA</given-names>
            </name>
            <name>
              <surname>Campalani</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>MacGowan</surname>
              <given-names>SW</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Repeat heart valve surgery: risk factors for operative mortality</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <year>2001</year>
          <volume>122</volume>
          <issue>5</issue>
          <fpage>913</fpage>
          <lpage>918</lpage>
        </element-citation>
      </ref>
      <ref id="B3">
        <label>3</label>
        <mixed-citation>3 Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation. 2002;106(24):3006-8.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Cribier</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Eltchaninoff</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Bash</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Borenstein</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Tron</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Bauer</surname>
              <given-names>F</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description</article-title>
          <source>Circulation</source>
          <year>2002</year>
          <volume>106</volume>
          <issue>24</issue>
          <fpage>3006</fpage>
          <lpage>3008</lpage>
        </element-citation>
      </ref>
      <ref id="B4">
        <label>4</label>
        <mixed-citation>4 Gaia DF, Breda JR, Duarte Ferreira CB, Marcondes de Souza JA, Macedo MT, Gimenes MV, et al. New Braile Inovare transcatheter aortic prosthesis: clinical results and follow-up. EuroIntervention. 2015;11(6):682-9.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Gaia</surname>
              <given-names>DF</given-names>
            </name>
            <name>
              <surname>Breda</surname>
              <given-names>JR</given-names>
            </name>
            <name>
              <surname>Duarte Ferreira</surname>
              <given-names>CB</given-names>
            </name>
            <name>
              <surname>Marcondes de Souza</surname>
              <given-names>JA</given-names>
            </name>
            <name>
              <surname>Macedo</surname>
              <given-names>MT</given-names>
            </name>
            <name>
              <surname>Gimenes</surname>
              <given-names>MV</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>New Braile Inovare transcatheter aortic prosthesis: clinical results and follow-up</article-title>
          <source>EuroIntervention</source>
          <year>2015</year>
          <volume>11</volume>
          <issue>6</issue>
          <fpage>682</fpage>
          <lpage>689</lpage>
        </element-citation>
      </ref>
      <ref id="B5">
        <label>5</label>
        <mixed-citation>5 Webb JG, Wood DA, Ye J, Gurvitch R, Masson JB, Rod&#233;s-Cabau J, et al. Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves. Circulation. 2010;121(16):1848-57.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Webb</surname>
              <given-names>JG</given-names>
            </name>
            <name>
              <surname>Wood</surname>
              <given-names>DA</given-names>
            </name>
            <name>
              <surname>Ye</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Gurvitch</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Masson</surname>
              <given-names>JB</given-names>
            </name>
            <name>
              <surname>Rod&#233;s-Cabau</surname>
              <given-names>J</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves</article-title>
          <source>Circulation</source>
          <year>2010</year>
          <volume>121</volume>
          <issue>16</issue>
          <fpage>1848</fpage>
          <lpage>1857</lpage>
        </element-citation>
      </ref>
      <ref id="B6">
        <label>6</label>
        <mixed-citation>6 Gurvitch R, Cheung A, Ye J, Wood DA, Willson AB, Toggweiler S, et al. Transcatheter valve-in-valve implantation for failed surgical bioprosthetic valves. J Am Coll Cardiol. 2011;58(21):2196-209.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Gurvitch</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Cheung</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Ye</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Wood</surname>
              <given-names>DA</given-names>
            </name>
            <name>
              <surname>Willson</surname>
              <given-names>AB</given-names>
            </name>
            <name>
              <surname>Toggweiler</surname>
              <given-names>S</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Transcatheter valve-in-valve implantation for failed surgical bioprosthetic valves</article-title>
          <source>J Am Coll Cardiol</source>
          <year>2011</year>
          <volume>58</volume>
          <issue>21</issue>
          <fpage>2196</fpage>
          <lpage>2209</lpage>
        </element-citation>
      </ref>
      <ref id="B7">
        <label>7</label>
        <mixed-citation>7 Wilbring M, Alexiou K, Tugtekin SM, Arzt S, Ibrahim K, Matschke K, et al. Pushing the limits-further evolutions of transcatheter valve procedures in the mitral position, including valve-in-valve, valve-in-ring, and valve-in-native-ring. J Thorac Cardiovasc Surg. 2014;147(1):210-9.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Wilbring</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Alexiou</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Tugtekin</surname>
              <given-names>SM</given-names>
            </name>
            <name>
              <surname>Arzt</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Ibrahim</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Matschke</surname>
              <given-names>K</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Pushing the limits-further evolutions of transcatheter valve procedures in the mitral position, including valve-in-valve, valve-in-ring, and valve-in-native-ring</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <year>2014</year>
          <volume>147</volume>
          <issue>1</issue>
          <fpage>210</fpage>
          <lpage>219</lpage>
        </element-citation>
      </ref>
      <ref id="B8">
        <label>8</label>
        <mixed-citation>8 Al Kindi AH, Salhab KF, Kapadia S, Roselli EE, Krishnaswamy A, Grant A, et al. Simultaneous transapical transcatheter aortic and mitral valve replacement in a high-risk patient with a previous mitral bioprosthesis. J Thorac Cardiovasc Surg. 2012;144(3):e90-1.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Al Kindi</surname>
              <given-names>AH</given-names>
            </name>
            <name>
              <surname>Salhab</surname>
              <given-names>KF</given-names>
            </name>
            <name>
              <surname>Kapadia</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Roselli</surname>
              <given-names>EE</given-names>
            </name>
            <name>
              <surname>Krishnaswamy</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Grant</surname>
              <given-names>A</given-names>
            </name>
            <etal/>
          </person-group>
          <article-title>Simultaneous transapical transcatheter aortic and mitral valve replacement in a high-risk patient with a previous mitral bioprosthesis</article-title>
          <source>J Thorac Cardiovasc Surg</source>
          <year>2012</year>
          <volume>144</volume>
          <issue>3</issue>
          <fpage>e90</fpage>
          <lpage>e91</lpage>
        </element-citation>
      </ref>
      <ref id="B9">
        <label>9</label>
        <mixed-citation>9 Misuraca L, Farah B, Tchetche D. Concomitant transapical treatment of aortic stenosis and degenerated mitral bioprosthesis with two 29 mm Edwards Sapien XT prostheses. J Invasive Cardiol. 2013;25(12):680-2.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Misuraca</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Farah</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Tchetche</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
          <article-title>Concomitant transapical treatment of aortic stenosis and degenerated mitral bioprosthesis with two 29 mm Edwards Sapien XT prostheses</article-title>
          <source>J Invasive Cardiol</source>
          <year>2013</year>
          <volume>25</volume>
          <issue>12</issue>
          <fpage>680</fpage>
          <lpage>682</lpage>
        </element-citation>
      </ref>
      <ref id="B10">
        <label>10</label>
        <mixed-citation>10 Aydin U, Gul M, Aslan S, Akkaya E, Yildirim A. Concomitant transapical transcatheter valve implantations: Edwards Sapien valve for severe mitral regurgitation in a patient with failing mitral bioprostheses and Jenavalve for the treatment of pure aortic regurgitation. Heart Surg Forum. 2015;18(2):E053-5.</mixed-citation>
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Aydin</surname>
              <given-names>U</given-names>
            </name>
            <name>
              <surname>Gul</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Aslan</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Akkaya</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Yildirim</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>Concomitant transapical transcatheter valve implantations: Edwards Sapien valve for severe mitral regurgitation in a patient with failing mitral bioprostheses and Jenavalve for the treatment of pure aortic regurgitation</article-title>
          <source>Heart Surg Forum</source>
          <year>2015</year>
          <volume>18</volume>
          <issue>2</issue>
          <fpage>E053</fpage>
          <lpage>E055</lpage>
        </element-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="s1" xml:lang="pt">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Relato de Caso</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Implante Transcateter Combinado de Biopr&#243;tese Valvar Mitral e A&#243;rtica por Via Transapical: Primeira Descri&#231;&#227;o no Brasil</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Sampaio</surname>
            <given-names>Roney Orismar</given-names>
          </name>
          <xref ref-type="aff" rid="aff2"/>
          <xref ref-type="corresp" rid="c2"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Paix&#227;o</surname>
            <given-names>Milena Ribeiro</given-names>
          </name>
          <xref ref-type="aff" rid="aff2"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Miranda</surname>
            <given-names>Thais Taveira</given-names>
          </name>
          <xref ref-type="aff" rid="aff2"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Veronese</surname>
            <given-names>Elinthon Tavares</given-names>
          </name>
          <xref ref-type="aff" rid="aff2"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Palma</surname>
            <given-names>Jos&#233; Hon&#243;rio de Almeida</given-names>
          </name>
          <xref ref-type="aff" rid="aff2"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Tarasoutchi</surname>
            <given-names>Fl&#225;vio</given-names>
          </name>
          <xref ref-type="aff" rid="aff2"/>
        </contrib>
        <aff id="aff2">
          <institution content-type="original">Instituto do Cora&#231;&#227;o (InCor) - Faculdade de Medicina da Universidade de S&#227;o Paulo, S&#227;o Paulo, SP - Brasil</institution>
        </aff>
      </contrib-group>
      <author-notes>
        <corresp id="c2"><bold>Correspond&#234;ncia: Roney Orismar Sampaio</bold> Rua Comandante Garcia d`Avila, 412. CEP 05654-040. Morumbi, SP - Brasil. E-mail: <email>orismar@cardiol.br</email>, <email>sampaioroney@yahoo.com.br</email>
				</corresp>
        <fn fn-type="con">
          <p>
            <bold>Contribui&#231;&#227;o dos autores</bold>
          </p>
          <p>Concep&#231;&#227;o e desenho da pesquisa, Obten&#231;&#227;o de financiamento e Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do intelectual importante: Sampaio RO, Paix&#227;o MR, Fonseca JHAP, Tarasoutchi F; Obten&#231;&#227;o de dados e An&#225;lise e interpreta&#231;&#227;o dos dados: Sampaio RO, Paix&#227;o MR, Miranda TT, Veronese ET, Fonseca JHAP; An&#225;lise estat&#237;stica: Sampaio RO, Paix&#227;o MR; Reda&#231;&#227;o do manuscrito: Sampaio RO, Paix&#227;o MR, Miranda TT, Tarasoutchi F.</p>
        </fn>
        <fn fn-type="conflict">
          <p>
            <bold>Potencial conflito de interesses</bold>
          </p>
          <p>Declaro n&#227;o haver conflito de interesses pertinentes.</p>
        </fn>
      </author-notes>
      <kwd-group xml:lang="pt">
        <title>Palavras-chave</title>
        <kwd>Substitui&#231;&#227;o da Valva A&#243;rtica Transcateter</kwd>
        <kwd>Implanta&#231;&#227;o de Pr&#243;tese Valva Card&#237;aca</kwd>
        <kwd>Pr&#243;teses Valvulares Card&#237;acas</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <sec sec-type="intro">
        <title>Introdu&#231;&#227;o</title>
        <p>Desde os prim&#243;rdios da cirurgia card&#237;aca, as valvas, quando n&#227;o era poss&#237;vel a repara&#231;&#227;o, eram substitu&#237;das por pr&#243;teses utilizando a circula&#231;&#227;o extracorp&#243;rea. Os bons resultados destes procedimentos s&#227;o bem conhecidos. Nos &#250;ltimos anos, alternativas minimamente invasivas t&#234;m sido desenvolvidas com o objetivo de possibilitar o tratamento de indiv&#237;duos de alto risco de complica&#231;&#245;es e morte com o procedimento convencional. Em 2002, foi realizado o primeiro implante valvar transcateter, o qual revolucionou o tratamento da estenose a&#243;rtica importante. Os equipamentos, t&#233;cnicas e habilidade evolu&#237;ram progressivamente desde ent&#227;o. Mais recentemente, a partir de 2009, passaram a ser realizados implantes valvares mitrais transcateter para tratamento da disfun&#231;&#227;o de pr&#243;tese <italic>(valve-in-valve)</italic>. Atualmente, o implante valvar transcateter &#233; um dos campos de maior desenvolvimento na cardiologia.</p>
      </sec>
      <sec sec-type="cases">
        <title>Relato do Caso</title>
        <p>Paciente do sexo masculino de 72 anos foi internado no pronto-socorro com quadro de insufici&#234;ncia card&#237;aca congestiva de piora progressiva. Apresentava hist&#243;rico de febre reum&#225;tica, doen&#231;a arterial coron&#225;ria, fibrila&#231;&#227;o atrial, insufici&#234;ncia renal cr&#244;nica (clearance de creatinina de 58 mL/min/1.72 m<sup>2</sup>) e amaurose secund&#225;ria &#224; degenera&#231;&#227;o macular da retina. Foi submetido a dois procedimentos cir&#250;rgicos card&#237;acos pr&#233;vios: pl&#225;stica da valva mitral e revasculariza&#231;&#227;o mioc&#225;rdica em 1993, troca de valva mitral por pr&#243;tese biol&#243;gica e nova revasculariza&#231;&#227;o mioc&#225;rdica em 1998. Houve grande dificuldade t&#233;cnica no &#250;ltimo procedimento, devido a m&#250;ltiplas ader&#234;ncias.</p>
        <p>Ao exame f&#237;sico na entrada apresentava: PA = 120/70 mmHg, FC = 60 bpm irregular. Ausculta card&#237;aca: primeira bulha hipofon&#233;tica, sopro sist&#243;lico crescendo/decrescendo 5+/6+ em foco a&#243;rtico e sopro holossistolico regurgitante 3+/6+ em foco mitral. Restante do exame f&#237;sico sem particularidades.</p>
        <p>Foi realizado ecocardiograma que demonstrou &#225;trio esquerdo de 74 mm, di&#226;metro diast&#243;lico do ventr&#237;culo esquerdo de 52 mm e sist&#243;lico de 32 mm, espessura do septo e parede posterior de 15 mm, press&#227;o sist&#243;lica da art&#233;ria pulmonar de 53 mmHg e fra&#231;&#227;o de eje&#231;&#227;o de 77 %. A pr&#243;tese biol&#243;gica mitral apresentava-se calcificada com gradiente AE-VE m&#233;dio de 13 mmHg, &#225;rea de 1,7 cm<sup>2</sup> e refluxo importante. A valva a&#243;rtica apresentava-se calcificada, com estenose importante (gradiente transvalvar de pico de 104 mmHg e m&#233;dio de 62 mmHg, &#225;rea valvar de 0,67 cm<sup>2</sup>) e refluxo discreto.</p>
        <p>A cineangiocoronariografia identificou ponte de veia safena para coron&#225;ria direita oclu&#237;da, art&#233;ria mam&#225;ria para descendente anterior p&#233;rvia, les&#245;es m&#250;ltiplas nos leitos nativos da coron&#225;ria direita e descendente anterior.</p>
        <p>A angiotomografia tor&#225;cica demonstrou escore de c&#225;lcio valvar de 3580 agatston e ateromatose coronariana e de aorta ascendente importantes (<xref ref-type="fig" rid="f3">Figura 1</xref>).</p>
        <p>
          <fig id="f3">
            <label>Figura 1</label>
            <caption>
              <title>Tomografia computadorizada de t&#243;rax demonstrando intensa calcifica&#231;&#227;o da aorta ascendente (A), valva a&#243;rtica (B) e jun&#231;&#227;o sinotubular (C). Medidas do di&#226;metro valvar (A) utilizada para defini&#231;&#227;o do tamanho da pr&#243;tese e da jun&#231;&#227;o sinotubular (B).</title>
            </caption>
            <graphic xlink:href="1678-4170-abc-109-05-0491-70118-gf01-pt.jpg"/></fig>
        </p>
        <p>N&#227;o havia fatores descompensadores agudos para a insufici&#234;ncia card&#237;aca, a n&#227;o ser a congest&#227;o atribu&#237;da &#224; doen&#231;a valvar a&#243;rtica e mitral. O risco pelo EuroScore II foi de 13,23%. Devido ao alto risco cir&#250;rgico e dificuldades t&#233;cnicas relatadas na &#250;ltima cirurgia, foi realizada discuss&#227;o pelo "Heart Team" e optou-se pelo tratamento percut&#226;neo duplo valvar atrav&#233;s de implante transcateter transapical e abordagem das les&#245;es coronarianas a posteriori, priorizando a resolu&#231;&#227;o da condi&#231;&#227;o hemodin&#226;mica do paciente.</p>
        <p>Em setembro de 2015, foi realizado o implante de biopr&#243;tese a&#243;rtica e, em seguida, mitral, ambas Inovare-Braile, n&#250;meros 28 e 30 respectivamente (<xref ref-type="fig" rid="f4">figura 2</xref>). N&#227;o houve intercorr&#234;ncias no procedimento. No terceiro dia p&#243;s-operat&#243;rio foi iniciado piperacilina e tazobactam para tratamento de pneumonia nosocomial. Apresentou ainda plaquetopenia (at&#233; 30.000/mm<sup>3</sup>), piora da insufici&#234;ncia renal aguda e derrame peric&#225;rdico moderado, revertidos rapidamente com o uso de corticoster&#243;ides e medidas cl&#237;nicas usuais. Ap&#243;s estabiliza&#231;&#227;o cl&#237;nica, o paciente recebeu alta hospitalar. O ecocardiograma tridimensional posterior &#224; alta demonstrou pr&#243;teses bem posicionadas, sem refluxo paraprot&#233;tico significativo na valva na posi&#231;&#227;o a&#243;rtica, gradiente VE-Ao pico 24 mmHg e m&#233;dio de 14 mmHg. Em posi&#231;&#227;o mitral, observou-se moderado refluxo paraprot&#233;tico, gradiente AE-VE m&#233;dio de 9 mmHg, &#225;rea mitral 1,5 cm<sup>2</sup>, PSAP 46 mmHg. Houve melhora cl&#237;nica para classe funcional II.</p>
        <p>
          <fig id="f4">
            <label>Figura 2</label>
            <caption>
              <title>Imagem de radioscopia demonstrando biopr&#243;teses Inovare-Braile em posi&#231;&#227;o a&#243;rtica n&#186; 28 j&#225; implantada (A) e em posi&#231;&#227;o mitral n&#186;30 imediatamente antes do implante (B). Observa-se a bainha com fio guia para implante da pr&#243;tese mitral (C), eletrodo de marcapasso tranvenoso (D), transdutor do ecocardiograma transesof&#225;gico (E), cateter de pigtail na aorta ascendente (F) e fios de esternorrafia pr&#233;via (G).</title>
            </caption>
            <graphic xlink:href="1678-4170-abc-109-05-0491-70118-gf02-pt.jpg"/></fig>
        </p>
      </sec>
      <sec sec-type="discussion">
        <title>Discuss&#227;o</title>
        <p>A disfun&#231;&#227;o de biopr&#243;tese valvar pode ser secund&#225;ria &#224; degenera&#231;&#227;o dos folhetos por desgaste, calcifica&#231;&#227;o ou ruptura, bem como pela forma&#231;&#227;o de <italic>pannus</italic> (tecido hospedeiro), trombo ou <italic>leak</italic> (vazamento) perivalvar. A durabilidade &#233; menor quando em posi&#231;&#227;o mitral, em indiv&#237;duos jovens, na presen&#231;a de mismatch de pr&#243;tese, insufici&#234;ncia renal e hiperparatiroidismo.<xref ref-type="bibr" rid="B1">1</xref><sup>,</sup><xref ref-type="bibr" rid="B2">2</xref>
				</p>
        <p>O aumento na utiliza&#231;&#227;o da pr&#243;tese biol&#243;gica, associado ao aumento da sobrevida dos indiv&#237;duos operados, tem tornado cada vez mais comuns as reabordagens cir&#250;rgicas. A cirurgia de troca valvar &#233;, at&#233; o presente momento, o procedimento de escolha nos casos de disfun&#231;&#227;o de pr&#243;tese, estando associada a maior morbidade e mortalidade em rela&#231;&#227;o &#224; primeira interven&#231;&#227;o. As dificuldades t&#233;cnicas das reabordagens cir&#250;rgicas podem implicar em maior tempo de circula&#231;&#227;o extracorp&#243;rea, necessidade de suporte transfusional, paralisia diafragm&#225;tica por les&#227;o do nervo fr&#234;nico, vasoplegia prolongada, les&#227;o de enxertos aorto-coron&#225;rios e risco aumentado de morte.<xref ref-type="bibr" rid="B1">1</xref><sup>,</sup><xref ref-type="bibr" rid="B2">2</xref>
				</p>
        <p>Os preditores de maior risco de complica&#231;&#227;o s&#227;o: idade avan&#231;ada, disfun&#231;&#227;o cognitiva, doen&#231;a vascular perif&#233;rica, doen&#231;a pulmonar cr&#244;nica, insufici&#234;ncia renal, insufici&#234;ncia card&#237;aca classe funcional IV pela <italic>New York Heart Association</italic> (NYHA), disfun&#231;&#227;o ventricular, procedimentos combinados, n&#250;mero de reabordagens, troca valvar mitral, cirurgia de emerg&#234;ncia, choque no pr&#233;-operat&#243;rio, trombose de pr&#243;tese, presen&#231;a de endocardite e abscesso paravalvar.<xref ref-type="bibr" rid="B1">1</xref><sup>,</sup><xref ref-type="bibr" rid="B2">2</xref>
				</p>
        <p>Os escores de risco cir&#250;rgico card&#237;aco mais utilizados na pr&#225;tica di&#225;ria s&#227;o o STS e o EuroSCORE II. O primeiro n&#227;o contempla o c&#225;lculo de risco para dupla troca valvar, como no caso em quest&#227;o. O risco estimado pelo EuroSCORE II foi de 13,23%, indicando elevada chance de morte.</p>
        <p>Uma das alternativas &#224; cirurgia valvar a&#243;rtica convencional para indiv&#237;duos de elevado risco cir&#250;rgico &#233; o implante transcateter, denominado <italic>Transcatheter Aortic Valve Implantantion</italic> (TAVI), o qual tem sido realizado desde 2002.<xref ref-type="bibr" rid="B3">3</xref> Desde ent&#227;o, j&#225; foram implantados mais de 50.000 dispositivos em todo o mundo, com desfechos cl&#237;nicos semelhantes &#224; cirurgia para pacientes com risco cir&#250;rgico elevado ou proibitivo.<xref ref-type="bibr" rid="B1">1</xref> As biopr&#243;teses podem ser expans&#237;veis por bal&#227;o ou auto-expans&#237;veis, ambas dependentes da presen&#231;a de calcifica&#231;&#227;o valvar a&#243;rtica para evitar seu deslocamento, por&#233;m, com maior risco de regurgita&#231;&#227;o perivalvar em caso de calcifica&#231;&#227;o extrema.</p>
        <p>As duas vias mais comuns para implante da TAVI s&#227;o via transfemoral e transapical - t&#233;cnica iniciada em 2006 com acesso por minitoracotomia sem necessidade de circula&#231;&#227;o extracorp&#243;rea. Embora a t&#233;cnica transapical seja mais invasiva, as vantagens frente &#224; via femoral s&#227;o maior facilidade no implante valvar pela proximidade do anel valvar do &#225;pice card&#237;aco, menor manipula&#231;&#227;o da aorta e sistema arterial perif&#233;rico reduzindo complica&#231;&#245;es vasculares e acidente vascular cerebral.<xref ref-type="bibr" rid="B1">1</xref><sup>,</sup><xref ref-type="bibr" rid="B4">4</xref> N&#227;o h&#225; impedimento para utiliza&#231;&#227;o desta t&#233;cnica em indiv&#237;duos com pr&#233;via revasculariza&#231;&#227;o do mioc&#225;rdio.</p>
        <p>O avan&#231;o nas t&#233;cnicas e materiais para implante valvar transcateter em valvas nativas permitiu que a estrat&#233;gia fosse adaptada para o tratamento de disfun&#231;&#227;o de pr&#243;teses biol&#243;gicas, t&#233;cnica denominada <italic>valve-in-valve</italic>. Os procedimentos <italic>valve-in-valve</italic> a&#243;rticos foram os primeiros a serem realizados, ampliando o uso dos equipamentos e habilidades idealizados para a TAVI. Desde ent&#227;o, procedimentos com pr&#243;teses expans&#237;veis por bal&#227;o e auto-expans&#237;veis tem sido realizados. Em seguida, o m&#233;todo foi ampliado para interven&#231;&#245;es mitrais, pulmonares e tric&#250;spides.<xref ref-type="bibr" rid="B1">1</xref><sup>,</sup><xref ref-type="bibr" rid="B5">5</xref><sup>,</sup><xref ref-type="bibr" rid="B6">6</xref>
				</p>
        <p>Os primeiros procedimentos <italic>valve-in-valve</italic> mitrais foram realizados em 2009, inicialmente com pr&#243;teses expans&#237;veis por bal&#227;o e, em seguida, tamb&#233;m com pr&#243;teses auto-expans&#237;veis. A partir de 2011, passaram a ser realizados implantes sobre o anel valvar p&#243;s anuloplastia, denominados <italic>valve-in-ring</italic>. Mais recentemente, a partir de 2014, iniciaram-se interven&#231;&#245;es transcateter mitrais em valva nativa.<xref ref-type="bibr" rid="B1">1</xref><sup>,</sup><xref ref-type="bibr" rid="B7">7</xref>
				</p>
        <p>Por &#250;ltimo, t&#234;m sido relatados nos &#250;ltimos anos procedimentos transcateter combinados.<xref ref-type="bibr" rid="B8">8</xref><sup>-</sup><xref ref-type="bibr" rid="B10">10</xref> Trata-se de tratamento que necessita de maior investiga&#231;&#227;o, sendo proposto exclusivamente nos casos em que o procedimento cir&#250;rgico convencional &#233; proibitivo. Sugerimos discuss&#227;o multidisciplinar com "Heart Team" para cada paciente com objetivo de designar com cautela o melhor tipo de interven&#231;&#227;o individualmente.</p>
      </sec>
      <sec sec-type="conclusions">
        <title>Conclus&#227;o</title>
        <p>H&#225; poucos relatos de interven&#231;&#227;o combinada em disfun&#231;&#245;es de valvas a&#243;rtica e mitral.<xref ref-type="bibr" rid="B8">8</xref><sup>-</sup><xref ref-type="bibr" rid="B10">10</xref> Este caso foi o primeiro realizado no Brasil com o implante da pr&#243;tese nacional Inovare Braile, demonstrando o enorme potencial para futuras interven&#231;&#245;es em pacientes selecionados.</p>
      </sec>
    </body>
    <back>
      <fn-group>
        <fn fn-type="financial-disclosure">
          <p>
            <bold>Fontes de financiamento</bold>
          </p>
          <p>O presente estudo n&#227;o teve fontes de financiamento externas.</p>
        </fn>
        <fn fn-type="other">
          <p>
            <bold>Vincula&#231;&#227;o acad&#234;mica</bold>
          </p>
          <p>N&#227;o h&#225; vincula&#231;&#227;o deste estudo a programas de p&#243;s-gradua&#231;&#227;o.</p>
        </fn>
      </fn-group>
    </back>
  </sub-article>
</article>