<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">qxmWPgJgKwz4rv6gVrg3Ggr</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2013002800002</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(13)10100200002</article-id>
      <article-id pub-id-type="doi">10.5935/abc.20130164</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigo Especial</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Recomenda&#231;&#245;es da sociedade brasileira de arritmias card&#237;acas para servi&#231;os de holter</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Lorga Filho</surname>
            <given-names>Adalberto</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Cintra</surname>
            <given-names>Fatima Dumas</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Lorga</surname>
            <given-names>Adalberto</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Grupi</surname>
            <given-names>Cesar Jos&#233;</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Pinho</surname>
            <given-names>Claudio</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Moreira</surname>
            <given-names>Dalmo Antonio Ribeiro</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Sobral Filho</surname>
            <given-names>Dario C.</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Brito</surname>
            <given-names>Fabio Sandoli de</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Kruse</surname>
            <given-names>Jos&#233; Claudio Lupi</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Sobral Neto</surname>
            <given-names>Jos&#233;</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <addr-line>
          <named-content content-type="state"/>
        </addr-line>
        <institution content-type="orgname">Sociedade Brasileira de Arritmias Card&#237;acas</institution>
        <country country="BR">Brazil</country>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>08</month>
        <year>2013</year>
      </pub-date>
      <volume>101</volume>
      <issue>2</issue>
      <fpage>101</fpage>
      <lpage>105</lpage>
      <history>
        <date date-type="received">
          <day>27</day>
          <month>05</month>
          <year>2013</year>
        </date>
        <date date-type="accepted">
          <day>24</day>
          <month>06</month>
          <year>2013</year>
        </date>
        <date date-type="rev-recd">
          <day>21</day>
          <month>06</month>
          <year>2013</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <abstract>
        <p>FUNDAMENTOS: In&#250;meros indicadores s&#227;o utilizados para assegurar a qualidade de um servi&#231;o; entretanto, a compet&#234;ncia m&#233;dica e o adequado fluxo de realiza&#231;&#227;o de um procedimento s&#227;o determinantes da qualidade final. Nesse contexto, a Sociedade Brasileira de Arritmias Card&#237;acas pretende recomendar par&#226;metros m&#237;nimos necess&#225;rios para garantir a excel&#234;ncia dos servi&#231;os de monitoriza&#231;&#227;o eletrocardiogr&#225;fica ambulatorial. OBJETIVOS: Recomendar compet&#234;ncias m&#233;dicas m&#237;nimas e as informa&#231;&#245;es necess&#225;rias para emiss&#227;o do laudo de Holter. M&#201;TODOS: O documento foi fundamentado no conceito de medicina baseada em evid&#234;ncia, e nas circunst&#226;ncias em que a evid&#234;ncia n&#227;o estava dispon&#237;vel a opini&#227;o de uma comiss&#227;o de reda&#231;&#227;o foi utilizada para a formula&#231;&#227;o da recomenda&#231;&#227;o. Essa comiss&#227;o foi formada por profissionais que apresentam viv&#234;ncia nas dificuldades do m&#233;todo e gest&#227;o na presta&#231;&#227;o de servi&#231;os nessa &#225;rea. RESULTADOS: O profissional respons&#225;vel pela an&#225;lise de Holter deve conhecer as patologias cardiovasculares e ter forma&#231;&#227;o consistente em eletrocardiografia, incluindo arritmias card&#237;acas e seus diagn&#243;sticos diferenciais. O laudo deve ser redigido de forma clara e objetiva. Os par&#226;metros m&#237;nimos que devem constar no laudo incluem as estat&#237;sticas do exame, assim como quantifica&#231;&#227;o e an&#225;lise dos dist&#250;rbios do ritmo observados durante a monitoriza&#231;&#227;o. CONCLUS&#195;O: A monitoriza&#231;&#227;o eletrocardiogr&#225;fica ambulatorial deve ser realizada por profissionais com viv&#234;ncia em an&#225;lise eletrocardiogr&#225;fica e o laudo deve conter os par&#226;metros m&#237;nimos mencionados nesse documento.</p>
      </abstract>
      <kwd-group xml:lang="pt" kwd-group-type="author-generated">
        <kwd>Arritmias Card&#237;acas</kwd>
        <kwd>Eletrocardiografia Ambulatorial</kwd>
        <kwd>Medicina Baseada em Evid&#234;ncias</kwd>
      </kwd-group>
      <pub-date publication-format="electronic" date-type="pub">
        <day>09</day>
        <month>09</month>
        <year>2013</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>
      <bold>ARTIGO ESPECIAL</bold>
    </p>
    <p>
      <bold>Recomenda&#231;&#245;es da sociedade brasileira de arritmias card&#237;acas para servi&#231;os de holter</bold>
    </p>
    <p>
      <bold>Adalberto Lorga Filho; Fatima Dumas Cintra; Adalberto Lorga; Cesar Jos&#233; Grupi; Claudio Pinho; Dalmo Antonio Ribeiro Moreira; Dario C. Sobral Filho; Fabio Sandoli de Brito; Jos&#233; Claudio Lupi Kruse; Jos&#233; Sobral Neto</bold>
    </p>
    <p>Sociedade Brasileira de Arritmias Card&#237;acas (SOBRAC) - Brasil</p>
    <p>
      <xref ref-type="corresp" rid="end">Correspond&#234;ncia</xref>
    </p>
    <p>
      <bold>RESUMO</bold>
    </p>
    <p><bold>FUNDAMENTOS:</bold> In&#250;meros indicadores s&#227;o utilizados para assegurar a qualidade de um servi&#231;o; entretanto, a compet&#234;ncia m&#233;dica e o adequado fluxo de realiza&#231;&#227;o de um procedimento s&#227;o determinantes da qualidade final. Nesse contexto, a Sociedade Brasileira de Arritmias Card&#237;acas pretende recomendar par&#226;metros m&#237;nimos necess&#225;rios para garantir a excel&#234;ncia dos servi&#231;os de monitoriza&#231;&#227;o eletrocardiogr&#225;fica ambulatorial. </p>
    <p><bold> OBJETIVOS:</bold> Recomendar compet&#234;ncias m&#233;dicas m&#237;nimas e as informa&#231;&#245;es necess&#225;rias para emiss&#227;o do laudo de Holter. </p>
    <p><bold>M&#201;TODOS:</bold> O documento foi fundamentado no conceito de medicina baseada em evid&#234;ncia, e nas circunst&#226;ncias em que a evid&#234;ncia n&#227;o estava dispon&#237;vel a opini&#227;o de uma comiss&#227;o de reda&#231;&#227;o foi utilizada para a formula&#231;&#227;o da recomenda&#231;&#227;o. Essa comiss&#227;o foi formada por profissionais que apresentam viv&#234;ncia nas dificuldades do m&#233;todo e gest&#227;o na presta&#231;&#227;o de servi&#231;os nessa &#225;rea. </p>
    <p><bold>RESULTADOS:</bold> O profissional respons&#225;vel pela an&#225;lise de Holter deve conhecer as patologias cardiovasculares e ter forma&#231;&#227;o consistente em eletrocardiografia, incluindo arritmias card&#237;acas e seus diagn&#243;sticos diferenciais. O laudo deve ser redigido de forma clara e objetiva. Os par&#226;metros m&#237;nimos que devem constar no laudo incluem as estat&#237;sticas do exame, assim como quantifica&#231;&#227;o e an&#225;lise dos dist&#250;rbios do ritmo observados durante a monitoriza&#231;&#227;o. </p>
    <p><bold>CONCLUS&#195;O:</bold> A monitoriza&#231;&#227;o eletrocardiogr&#225;fica ambulatorial deve ser realizada por profissionais com viv&#234;ncia em an&#225;lise eletrocardiogr&#225;fica e o laudo deve conter os par&#226;metros m&#237;nimos mencionados nesse documento.</p>
    <p><bold>Palavras-chave:</bold> Arritmias Card&#237;acas / diagn&#243;stico; Eletrocardiografia Ambulatorial; Medicina Baseada em Evid&#234;ncias.</p>
    <p>
      <bold>Introdu&#231;&#227;o</bold>
    </p>
    <p>A monitoriza&#231;&#227;o ambulatorial do eletrocardiograma, designado simplesmente Holter ou Holter de 24 horas, &#233; um m&#233;todo n&#227;o invasivo largamente utilizado para avaliar anormalidades eletrocardiogr&#225;ficas de pacientes com variadas doen&#231;as card&#237;acas ou n&#227;o card&#237;acas e indiv&#237;duos normais em condi&#231;&#245;es ou situa&#231;&#245;es especiais. Desenvolvido na d&#233;cada de 1960, sofreu grande desenvolvimento tecnol&#243;gico nos &#250;ltimos anos. Atualmente, o sistema de registro e armazenamento utilizado (gravador de Holter) &#233; digital, usualmente com tr&#234;s canais. O tamanho do equipamento &#233; pequeno (aproximadamente 8,5 x 5,3 x 2,0 cm) e leve (pesam de 45 a 90 gramas), operado a bateria, pilha alcalina ou pilha comum. Prote&#231;&#227;o adicional com resist&#234;ncia para imers&#227;o em fluidos &#233; recomendada. O registro &#233; feito atrav&#233;s de eletrodos bipolares em tr&#234;s canais (deriva&#231;&#245;es). O gravador deve possuir um bot&#227;o marcador de eventos, que pode ser ativado pelo paciente em condi&#231;&#245;es especiais, como na ocorr&#234;ncia de um sintoma. </p>
    <p>A partir da d&#233;cada de 1980, com a evolu&#231;&#227;o do armazenamento eletr&#244;nico, esses equipamentos evolu&#237;ram da an&#225;lise em tempo real para o armazenamento de dados digitalizados. Essas condi&#231;&#245;es permitiram grande incremento na fidelidade dos registros, minimizando distor&#231;&#245;es poss&#237;veis de ocorrer nas grava&#231;&#245;es em fita, al&#233;m das imperfei&#231;&#245;es geradas pelos fatores mec&#226;nicos inerentes aos mecanismos respons&#225;veis pela rota&#231;&#227;o do sistema. A an&#225;lise dos dados ganhou em acur&#225;cia e detalhamento. As frequ&#234;ncias de 200 Hz s&#227;o adequadas para a an&#225;lise dos desvios do segmento ST e dist&#250;rbios do ritmo. Para a obten&#231;&#227;o do ECG de alta resolu&#231;&#227;o &#233; indispens&#225;vel a disponibilidade de frequ&#234;ncias de 1000 Hz.</p>
    <p>Recentemente, foram disponibilizados no mercado gravadores digitais com op&#231;&#227;o de aquisi&#231;&#227;o dos dados em 12 deriva&#231;&#245;es, por meio de um cabo com 10 eletrodos ou apenas 5 eletrodos quando associadas as deriva&#231;&#245;es ortogonais (X, Y, e Z) da vetocardiografia. O software gera o registro do eletrocardiograma com as 12 deriva&#231;&#245;es convencionais, em qualquer momento da an&#225;lise.</p>
    <p>A obten&#231;&#227;o de um registro eletrocardiogr&#225;fico de qualidade &#233; a condi&#231;&#227;o fundamental para que o exame proposto possa ser &#250;til e confi&#225;vel, fornecendo as informa&#231;&#245;es pretendidas. Quando declina a qualidade do exame, diminui tamb&#233;m a quantidade de informa&#231;&#227;o e cresce enormemente o tempo para a edi&#231;&#227;o necess&#225;ria.</p>
    <p>
      <bold>Aplica&#231;&#227;o cl&#237;nica e tipos de monitoriza&#231;&#227;o ambulatorial do eletrocardiograma</bold>
    </p>
    <p>Tipicamente, a monitoriza&#231;&#227;o ambulatorial eletrocardiogr&#225;fica &#233; classificada de acordo com a forma de monitoriza&#231;&#227;o em grava&#231;&#245;es cont&#237;nuas e intermitentes. De modo geral, as grava&#231;&#245;es cont&#237;nuas ocorrem por 24h a 48h e as grava&#231;&#245;es intermitentes acontecem por per&#237;odos maiores. Os aparelhos destinados a grava&#231;&#245;es intermitentes, denominados monitor de eventos, incorporam uma al&#231;a de mem&#243;ria (loop) que permite o armazenamento de tra&#231;ados aleat&#243;rios ou motivados por algum sintoma cl&#237;nico. Apesar de n&#227;o haver estudos cl&#237;nicos que avaliem o perfil de pacientes que melhor se beneficiem da grava&#231;&#227;o cont&#237;nua ou intermitente, a frequ&#234;ncia com que esse sintoma ocorre &#233; o par&#226;metro utilizado para escolha entre os dois m&#233;todos. Dessa forma, em pacientes com sintomas espor&#225;dicos, o uso do gravador de eventos pode ser o mais adequado, especialmente para a avalia&#231;&#227;o de pr&#233;-s&#237;ncope; s&#237;ncope e palpita&#231;&#245;es espor&#225;dicas<sup>1</sup>.</p>
    <p>O monitor de eventos implant&#225;vel est&#225; dispon&#237;vel no mercado para documenta&#231;&#227;o de sintomas de ocorr&#234;ncia rara. Trata-se de pequenos dispositivos introduzidos no subcut&#226;neo da regi&#227;o infraclavicular, que podem manter a monitoriza&#231;&#227;o eletrocardiogr&#225;fica circular por longos per&#237;odos.</p>
    <p>A utiliza&#231;&#227;o do Holter de 24 horas 3 canais, digital na pr&#225;tica cl&#237;nica, tem como objetivo caracterizar e diagnosticar ocorr&#234;ncias de comportamento el&#233;trico anormal do cora&#231;&#227;o durante atividades di&#225;rias (sono, trabalho, exerc&#237;cios, estresse emocional, repouso etc.). Dessa forma, sua utiliza&#231;&#227;o &#233; voltada principalmente, mas n&#227;o exclusivamente, para arritmias card&#237;acas, sintom&#225;ticas ou n&#227;o; entretanto, a avalia&#231;&#227;o do segmento ST com ou sem arritmias associadas (pr&#233;-excita&#231;&#227;o intermitente, altera&#231;&#245;es tipo Brugada, isquemia silenciosa ou n&#227;o, QT curto ou longo, transit&#243;rio ou n&#227;o etc.) e a an&#225;lise do sistema nervoso aut&#244;nomo por meio da variabilidade da frequ&#234;ncia card&#237;aca tamb&#233;m est&#227;o dispon&#237;veis em uma an&#225;lise de Holter<sup>2</sup>. Al&#233;m da avalia&#231;&#227;o diagn&#243;stica, podemos utilizar o Holter para verificar a efic&#225;cia terap&#234;utica dos dist&#250;rbios do ritmo card&#237;aco quer sejam farmacol&#243;gicas ou invasivas, e tamb&#233;m para estratifica&#231;&#227;o de risco de morte s&#250;bita (<xref ref-type="fig" rid="qua01">Quadro 1</xref>).</p>
    <fig id="qua01">
      <graphic xlink:href="1678-4170-abc-101-02-0101-30164-gf01.jpg"/></fig>
    <p>As medidas da varia&#231;&#227;o da frequ&#234;ncia card&#237;aca batimento a batimento, em condi&#231;&#245;es basais ou em resposta a um dado est&#237;mulo padronizado, podem constituir uma medida objetiva e n&#227;o invasiva de quantifica&#231;&#227;o do estado auton&#244;mico em condi&#231;&#245;es fisiol&#243;gicas e patol&#243;gicas<sup>3</sup>. As t&#233;cnicas de an&#225;lises mais frequentemente utilizadas para a determina&#231;&#227;o da variabilidade da frequ&#234;ncia card&#237;aca s&#227;o obtidas no dom&#237;nio do tempo e no dom&#237;nio da frequ&#234;ncia.</p>
    <p>As medidas no dom&#237;nio do tempo s&#227;o usualmente realizadas em 24 horas. Nesses registros, os complexos QRS s&#227;o detectados sendo exclu&#237;dos os artefatos e batimentos ect&#243;picos, para n&#227;o prejudicarem as an&#225;lises estat&#237;sticas. Os ciclos de frequ&#234;ncia entre os complexos QRS s&#227;o determinados e as distribui&#231;&#245;es estat&#237;sticas de todos os ciclos s&#227;o calculadas, como a m&#233;dia e o desvio padr&#227;o. O dom&#237;nio da frequ&#234;ncia constitui outra forma de an&#225;lise da variabilidade da frequ&#234;ncia card&#237;aca, cujo princ&#237;pio reside no fato que todo intervalo NN pode ser decomposto em uma s&#233;rie de componentes oscilat&#243;rios, com diferentes freq&#252;&#234;ncias e amplitudes.</p>
    <p>As principais arritmias card&#237;acas que podem ser diagnosticadas pelo Holter de 24 horas 3 canais digital est&#227;o descritas no <xref ref-type="fig" rid="a02qua02">Quadro 2</xref>.</p>
    <p content-type="asset">
      <fig id="a02qua02">
        <graphic xlink:href="1678-4170-abc-101-02-0101-30164-gf02.jpg"/></fig>
    </p>
    <p>
      <bold>Aspectos t&#233;cnicos do m&#233;todo</bold>
    </p>
    <p>Apesar de a coloca&#231;&#227;o de eletrodos parecer um fator pouco significante no Holter, trata-se de um aspecto fundamental para o sucesso do procedimento. A pele deve ser adequadamente limpa com &#225;lcool para a remo&#231;&#227;o de oleosidade e seca antes da aplica&#231;&#227;o dos eletrodos. Os eletrodos devem ser pressionados nas &#225;reas adesivas perif&#233;ricas e n&#227;o no centro para evitar o deslocamento do gel. Um eletrodo de boa qualidade &#233; custo-efetivo, uma vez que assegura uma melhor qualidade do tra&#231;ado e menor irrita&#231;&#227;o na pele. As recomenda&#231;&#245;es t&#233;cnicas para a realiza&#231;&#227;o do Holter de 24h est&#227;o descritas no <xref ref-type="fig" rid="qua03">Quadro 3</xref>.</p>
    <fig id="qua03">
      <graphic xlink:href="1678-4170-abc-101-02-0101-30164-gf03.jpg"/></fig>
    <p>O Holter deve ser realizado com m&#237;nimo de 3 canais bipolares. Se por um lado o aumento no n&#250;mero de eletrodos aumenta o desconforto do paciente, por outro lado a localiza&#231;&#227;o da origem de algumas arritmias &#233; poss&#237;vel com um maior n&#250;mero de deriva&#231;&#245;es. Apesar de a individualiza&#231;&#227;o dos casos ser necess&#225;ria, na pr&#225;tica cl&#237;nica o uso de 3 deriva&#231;&#245;es parece atender a maioria dos casos.</p>
    <p>A escolha das deriva&#231;&#245;es deve ser padronizada para permitir m&#225;xima informa&#231;&#227;o em rela&#231;&#227;o a morfologia e com boa amplitude para evitar a falha de captura do batimento. Os canais eletrocardiogr&#225;ficos utilizados para a monitoriza&#231;&#227;o usualmente s&#227;o as deriva&#231;&#245;es bipolares modificadas: V5; V3 e deriva&#231;&#227;o inferior<sup>4</sup>.</p>
    <p>A recomenda&#231;&#227;o para a densidade de artefatos durante a monitoriza&#231;&#227;o &#233; de no m&#225;ximo 5%. Valores superiores a isso devem ser analisados em rela&#231;&#227;o &#224; necessidade de repeti&#231;&#227;o da grava&#231;&#227;o. Em alguns casos em que a onda T &#233; apiculada pode ocorrer detec&#231;&#227;o indevida como batimento e a necessidade de excluir esses complexos ocasionando uma taxa de artefatos superestimada que n&#227;o interfere na analise global do exame. </p>
    <p>A variabilidade na distribui&#231;&#227;o de arritmias dia a dia &#233; uma realidade<sup>5-7</sup>. A maioria dos estudos cl&#237;nicos com arritmias utiliza a dura&#231;&#227;o de 24 horas; entretanto, a utiliza&#231;&#227;o de per&#237;odos mais prolongados de monitoriza&#231;&#227;o ou repeti&#231;&#227;o de monitoriza&#231;&#227;o pode aumentar a acur&#225;cia do exame<sup>8</sup>. A Sociedade Brasileira de Arritmias Card&#237;acas preconiza monitoriza&#231;&#227;o por no m&#237;nimo 18 horas, incluindo os per&#237;odos de vig&#237;lia e sono para an&#225;lise e laudo da monitoriza&#231;&#227;o ambulatorial eletrocardiogr&#225;fica.</p>
    <p>
      <bold>Conhecimento e treinamento m&#237;nimo necess&#225;rios para an&#225;lise de tra&#231;ados de monitoriza&#231;&#227;o eletrocardiogr&#225;fica</bold>
    </p>
    <p>O profissional respons&#225;vel pela an&#225;lise de Holter, al&#233;m do conhecimento das patologias cardiovasculares, deve ter forma&#231;&#227;o consistente espec&#237;fica em eletrocardiografia, incluindo arritmias card&#237;acas e seus diagn&#243;sticos diferenciais. A correta interpreta&#231;&#227;o das altera&#231;&#245;es do segmento ST, isquemia card&#237;aca e variabilidade da frequ&#234;ncia card&#237;aca tamb&#233;m constitui atributo necess&#225;rio para emiss&#227;o de um laudo de Holter. O <xref ref-type="fig" rid="a02qua04">Quadro 4</xref> resume os pontos principais de conhecimento m&#233;dico para avalia&#231;&#227;o a monitoriza&#231;&#227;o ambulatorial eletrocardiogr&#225;fica.</p>
    <p content-type="asset">
      <fig id="a02qua04">
        <graphic xlink:href="1678-4170-abc-101-02-0101-30164-gf04.jpg"/></fig>
    </p>
    <p>
      <bold>Comprova&#231;&#227;o da compet&#234;ncia</bold>
    </p>
    <p>A avalia&#231;&#227;o e interpreta&#231;&#227;o do tra&#231;ado da monitoriza&#231;&#227;o ambulatorial eletrocardiogr&#225;fica &#233; um ato m&#233;dico a ser realizado exclusivamente por m&#233;dicos inscritos no Conselho Regional de Medicina e aptos ao exerc&#237;cio profissional. A recomenda&#231;&#227;o da Sociedade Brasileira de Arritmias card&#237;acas (Sobrac) &#233; de que o profissional possua t&#237;tulo de especialista de arritmia cl&#237;nica ou eletrofisiologia com experi&#234;ncia supervisionada vivenciada em no m&#237;nimo 150 tra&#231;ados<sup>9</sup>, al&#233;m de julgar-se competente em rela&#231;&#227;o ao conhecimento m&#233;dico necess&#225;rio listado no <xref ref-type="fig" rid="a02qua04">Quadro 4</xref>.</p>
    <p>
      <bold>Papel do t&#233;cnico em Holter</bold>
    </p>
    <p>A atua&#231;&#227;o do t&#233;cnico em Holter em um determinado servi&#231;o est&#225; na depend&#234;ncia da prefer&#234;ncia do m&#233;dico respons&#225;vel. Suas atribui&#231;&#245;es s&#227;o listadas no <xref ref-type="fig" rid="a02qua05">Quadro 5</xref>. Vale lembrar que &#233; proibida a atua&#231;&#227;o isoladamente do t&#233;cnico sem o respaldo e supervis&#227;o de um profissional m&#233;dico apto conforme as recomenda&#231;&#245;es do <xref ref-type="fig" rid="a02qua04">quadro 4</xref>.</p>
    <p content-type="asset">
      <fig id="a02qua05">
        <graphic xlink:href="1678-4170-abc-101-02-0101-30164-gf05.jpg"/></fig>
    </p>
    <p>A habilita&#231;&#227;o desse profissional deve ser feita por institui&#231;&#245;es reconhecidas ou est&#225;gio com profissional reconhecido na &#225;rea com experi&#234;ncia vivenciada em um m&#237;nimo de 1000 tra&#231;ados. </p>
    <p>
      <bold>Laudo m&#237;nimo em Monitoriza&#231;&#227;o Ambulatorial Eletrocardiogr&#225;fica</bold>
    </p>
    <p>O laudo deve ser redigido de forma clara e objetiva. Recomenda-se o seu arquivamento digital por per&#237;odo m&#237;nimo de cinco anos, sendo recomendados dez anos. Os par&#226;metros que devem constar no laudo encontram-se no <xref ref-type="fig" rid="a02qua06">Quadro 6</xref>.</p>
    <p content-type="asset">
      <fig id="a02qua06">
        <graphic xlink:href="1678-4170-abc-101-02-0101-30164-gf06.jpg"/></fig>
    </p>
    <p>
      <bold>Lista completa dos autores:</bold>
    </p>
    <p>Adalberto Lorga Filho, Fatima Dumas Cintra, Adalberto Lorga, Cesar Grupi, Claudio Pinho, Dalmo Moreira, Dario Sobral, Fabio Sandoli de Brito, Jose Claudio Lupi Krusi, Jose Sobral Neto, Olga Ferreira de Souza, Jos&#233; Tarc&#237;sio Medeiros de Vasconcelos.</p>
    <p>
      <bold>Contribui&#231;&#227;o dos autores</bold>
    </p>
    <p>Concep&#231;&#227;o e desenho da pesquisa: Lorga Filho A, Lorga A; Obten&#231;&#227;o de dados: Lorga Filho A, Cintra FD; An&#225;lise e interpreta&#231;&#227;o dos dados: Cintra FD; Reda&#231;&#227;o do manuscrito: Cintra FD, Grupi C, Pinho C, Moreira D, Sobral Filho DC, Brito FS, Krusi JCL, Sobral Neto J; Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do intelectual: Lorga Filho A, Cintra FD, Lorga A, Grupi C, Pinho C, Moreira D, Sobral Filho DC, Brito FS, Krusi JCL, Sobral Neto J.</p>
    <p>
      <bold>Potencial Conflito de Interesses</bold>
    </p>
    <p>Declaro n&#227;o haver conflito de interesses pertinentes.</p>
    <p>
      <bold>Fontes de Financiamento</bold>
    </p>
    <p>O presente estudo n&#227;o teve fontes de financiamento externas.</p>
    <p>
      <bold>Vincula&#231;&#227;o Acad&#234;mica</bold>
    </p>
    <p>N&#227;o h&#225; vincula&#231;&#227;o deste estudo a programas de p&#243;s-gradua&#231;&#227;o.</p>
    <p>
      <fn id="end" fn-type="corresp">
        <label>
          <bold>Correspond&#234;ncia:</bold>
        </label>
        <p> Fatima Dumas Cintra </p>
        <p> Alameda Taurus, 146, Residencial Genesis I, Alphaville </p>
        <p> CEP 06543-670, Santana de Parna&#237;ba, SP - Brasil </p>
        <p> E-mail: </p>
        <p><email xlink:href="fatimacintra@cardiol.br">fatimacintra@cardiol.br</email>, </p>
        <p>
          <email xlink:href="fatimadc@einstein.br">fatimadc@einstein.br</email>
        </p>
      </fn>
    </p>
    <p>Artigo recebido em 27/05/13; revisado em 21/06/13; aceito em 24/06/13.</p>
  </body>
  <back>
    <ref-list>
      <ref id="B1">
        <mixed-citation>1. Edvardsson N, Frykman V, van Mechelen R, Mitro P, Mohii-Oskarsson A, Pasqui&#233; JL, et al; PICTURE Study Investigators. Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry. Europace. 2011;13(2):262-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry</article-title>
          <source>Europace</source>
          <date>
            <year>2011</year>
          </date>
          <fpage>262</fpage>
          <lpage>9</lpage>
          <issue>2</issue>
          <volume>13</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Edvardsson</surname>
              <given-names>N</given-names>
            </name>
            <name>
              <surname>Frykman</surname>
              <given-names>V</given-names>
            </name>
            <name>
              <surname>van Mechelen</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Mitro</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Mohii-Oskarsson</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Pasqui&#233;</surname>
              <given-names>JL</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Scanavacca MI, de Brito FS, Maia I, Hachul D, Gizzi J, Lorga A, et al; Sociedade Brasileira de Cardiologia. Guidelines for the evaluation and treatment of patients with cardiac arrhythmias. Arq Bras Cardiol. 2002;79(Suppl 5):1-50.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Guidelines for the evaluation and treatment of patients with cardiac arrhythmias</article-title>
          <source>Arq Bras Cardiol</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>1</fpage>
          <lpage>50</lpage>
          <volume>79</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Scanavacca</surname>
              <given-names>MI</given-names>
            </name>
            <name>
              <surname>de Brito</surname>
              <given-names>FS</given-names>
            </name>
            <name>
              <surname>Maia</surname>
              <given-names>I</given-names>
            </name>
            <name>
              <surname>Hachul</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Gizzi</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Lorga</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. Cerutti S, Bianchi AM, Mainardi LT. Spectral analysis of heart rate variability signal. In: Malik M, Camm AJ. (editors). Heart rate variability. New York: Futura Publishing Company, Inc; 1995. p. 63-74.</mixed-citation>
        <element-citation publication-type="book">
          <source>Heart rate variability</source>
          <date>
            <year>1995</year>
          </date>
          <fpage>63</fpage>
          <lpage>74</lpage>
          <person-group person-group-type="author">
            <name>
              <surname>Cerutti</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Bianchi</surname>
              <given-names>AM</given-names>
            </name>
            <name>
              <surname>Mainardi</surname>
              <given-names>LT</given-names>
            </name>
            <name>
              <surname>Malik</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Camm</surname>
              <given-names>AJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Crawford MH, Bernstein SJ, Deedwania PC, DiMarco JP, Ferrick KJ, Garson A Jr, et al.. ACC/AHA Guidelines for Ambulatory Electrocardiography. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines(Committee to Revise the Guidelines for Ambulatory Electrocardiography). J Am Coll Cardiol. 1999;34(3):912-48.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>ACC/AHA Guidelines for Ambulatory Electrocardiography: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines(Committee to Revise the Guidelines for Ambulatory Electrocardiography)</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>1999</year>
          </date>
          <fpage>912</fpage>
          <lpage>48</lpage>
          <issue>3</issue>
          <volume>34</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Crawford</surname>
              <given-names>MH</given-names>
            </name>
            <name>
              <surname>Bernstein</surname>
              <given-names>SJ</given-names>
            </name>
            <name>
              <surname>Deedwania</surname>
              <given-names>PC</given-names>
            </name>
            <name>
              <surname>DiMarco</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>Ferrick</surname>
              <given-names>KJ</given-names>
            </name>
            <name>
              <surname>Garson Jr</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. DiMarco JP, Philbrick JT. Use of ambulatory electrocardiographic (Holter) monitoring. Ann Intern Med. 1990;113(1):53-68.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Use of ambulatory electrocardiographic (Holter) monitoring</article-title>
          <source>Ann Intern Med</source>
          <date>
            <year>1990</year>
          </date>
          <fpage>53</fpage>
          <lpage>68</lpage>
          <issue>1</issue>
          <volume>113</volume>
          <person-group person-group-type="author">
            <name>
              <surname>DiMarco</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>Philbrick</surname>
              <given-names>JT</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B6">
        <mixed-citation>6. Pratt CM, Theroux P, Slymen D, Riodar-Bennett A, Morisette D, Galloway A, et al. Spontaneous variability of ventricular arrhythmias in patients at increased risk for sudden death after acute myocardial infarction: consecutive ambulatory electrocardiographic recordings of 88 patients. Am J Cardiol. 1987;59(4):278-83.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Spontaneous variability of ventricular arrhythmias in patients at increased risk for sudden death after acute myocardial infarction: consecutive ambulatory electrocardiographic recordings of 88 patients</article-title>
          <source>Am J Cardiol</source>
          <date>
            <year>1987</year>
          </date>
          <fpage>278</fpage>
          <lpage>83</lpage>
          <issue>4</issue>
          <volume>59</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Pratt</surname>
              <given-names>CM</given-names>
            </name>
            <name>
              <surname>Theroux</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Slymen</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Riodar-Bennett</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Morisette</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Galloway</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B7">
        <mixed-citation>7. Mulrow JP, Healy MJ, McKenna WJ. Variability of ventricular arrhythmias in hypertrophic cardiomyopathy and implications for treatment. Am J Cardiol. 1986;58(7):615-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Variability of ventricular arrhythmias in hypertrophic cardiomyopathy and implications for treatment</article-title>
          <source>Am J Cardiol</source>
          <date>
            <year>1986</year>
          </date>
          <fpage>615</fpage>
          <lpage>8</lpage>
          <issue>7</issue>
          <volume>58</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Mulrow</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>Healy</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>McKenna</surname>
              <given-names>WJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B8">
        <mixed-citation>8. Bass EB, Curtiss EI, Arena VC, Hanusa BH, Cecchetti A, Karpf M, et al. The duration of Holter monitoring in patients with syncope: is 24 hours enough? Arch Intern Med. 1990;150(5):1073-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>The duration of Holter monitoring in patients with syncope: is 24 hours enough?</article-title>
          <source>Arch Intern Med</source>
          <date>
            <year>1990</year>
          </date>
          <fpage>1073</fpage>
          <lpage>8</lpage>
          <issue>5</issue>
          <volume>150</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Bass</surname>
              <given-names>EB</given-names>
            </name>
            <name>
              <surname>Curtiss</surname>
              <given-names>EI</given-names>
            </name>
            <name>
              <surname>Arena</surname>
              <given-names>VC</given-names>
            </name>
            <name>
              <surname>Hanusa</surname>
              <given-names>BH</given-names>
            </name>
            <name>
              <surname>Cecchetti</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Karpf</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B9">
        <mixed-citation>9. Kadish AH, Buxton AE, Kennedy HL, Knight BP, Mason JW, Schuger CD, et al; American College of Cardiology/American Heart Association/American College of Physicians-American Society of Internal Medicine Task Force; International Society for Holter and Noninvasive Electrocardiology. ACC/AHA clinical competence statement on electrocardiography and ambulatory electrocardiography: A report of the ACC/AHA/ACP-ASIM task force on clinical competence (ACC/AHA Committee to develop a clinical competence statement on electrocardiography and ambulatory electrocardiography) endorsed by the International Society for Holter and noninvasive electrocardiology. Circulation. 2001;104(25):3169-78.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>ACC/AHA clinical competence statement on electrocardiography and ambulatory electrocardiography: A report of the ACC/AHA/ACP-ASIM task force on clinical competence (ACC/AHA Committee to develop a clinical competence statement on electrocardiography and ambulatory electrocardiography) endorsed by the International Society for Holter and noninvasive electrocardiology</article-title>
          <source>Circulation</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>3169</fpage>
          <lpage>78</lpage>
          <issue>25</issue>
          <volume>104</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Kadish</surname>
              <given-names>AH</given-names>
            </name>
            <name>
              <surname>Buxton</surname>
              <given-names>AE</given-names>
            </name>
            <name>
              <surname>Kennedy</surname>
              <given-names>HL</given-names>
            </name>
            <name>
              <surname>Knight</surname>
              <given-names>BP</given-names>
            </name>
            <name>
              <surname>Mason</surname>
              <given-names>JW</given-names>
            </name>
            <name>
              <surname>Schuger</surname>
              <given-names>CD</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Special Article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Recommendations of the Brazilian society of cardiac arrhythmias for holter monitoring services</article-title>
      </title-group>
      <abstract xml:lang="en">
        <p>BACKGROUND: There are innumerous indicators to assure the quality of a service. However, medical competence and the proper performance of a procedure determine its final quality. The Brazilian Society of Cardiac Arrhythmias recommends minimum parameters necessary to guarantee the excellence of ambulatory electrocardiographic monitoring services. OBJECTIVE: To recommend minimum medical competences and the information required to issue a Holter monitoring report. METHODS: This study was grounded in the concept of evidence-based medicine and, when evidence was not available, the opinion of a writing committee was used to formulate the recommendation. That committee consisted of professionals with experience on the difficulties of the method and management in providing services in that area. RESULTS: The professional responsible for the Holter monitoring analysis should know cardiovascular pathologies and have consistent formation on electrocardiography, including cardiac arrhythmias and their differential diagnoses. The report should be written in a clear and objective way. The minimum parameters that comprise a Holter report should include statistics of the exam, as well as quantification and analysis of the rhythm disorders observed during monitoring. CONCLUSION: Ambulatory electrocardiographic monitoring should be performed by professionals knowledgeable about electrocardiographic analysis, whose report should comprise the minimum parameters mentioned in this document.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>Arrhythmias, Cardiac</kwd>
        <kwd>Electrocardiography</kwd>
        <kwd>Evidence-Based Mediate Ambulatory</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>SPECIAL ARTICLE</bold>
      </p>
      <p>
        <bold>Recommendations of the brazilian society of cardiac arrhythmias for holter monitoring services</bold>
      </p>
      <p>
        <bold>Adalberto Lorga Filho; Fatima Dumas Cintra; Adalberto Lorga; Cesar Jos&#233; Grupi; Claudio Pinho; Dalmo Antonio Ribeiro Moreira; Dario C. Sobral Filho; Fabio Sandoli de Brito; Jos&#233; Claudio Lupi Kruse; Jos&#233; Sobral Neto</bold>
      </p>
      <p>Sociedade Brasileira de Arritmias Card&#237;acas (SOBRAC) - Brazil</p>
      <p>Mailing Address</p>
      <p>
        <bold>ABSTRACT</bold>
      </p>
      <p><bold>BACKGROUND:</bold> There are innumerous indicators to assure the quality of a service. However, medical competence and the proper performance of a procedure determine its final quality. The Brazilian Society of Cardiac Arrhythmias recommends minimum parameters necessary to guarantee the excellence of ambulatory electrocardiographic monitoring services.</p>
      <p><bold>OBJECTIVE:</bold> To recommend minimum medical competences and the information required to issue a Holter monitoring report.</p>
      <p><bold>METHODS:</bold> This study was grounded in the concept of evidence-based medicine and, when evidence was not available, the opinion of a writing committee was used to formulate the recommendation. That committee consisted of professionals with experience on the difficulties of the method and management in providing services in that area.</p>
      <p><bold>RESULTS:</bold> The professional responsible for the Holter monitoring analysis should know cardiovascular pathologies and have consistent formation on electrocardiography, including cardiac arrhythmias and their differential diagnoses. The report should be written in a clear and objective way. The minimum parameters that comprise a Holter report should include statistics of the exam, as well as quantification and analysis of the rhythm disorders observed during monitoring.</p>
      <p><bold>CONCLUSION:</bold> Ambulatory electrocardiographic monitoring should be performed by professionals knowledgeable about electrocardiographic analysis, whose report should comprise the minimum parameters mentioned in this document.</p>
      <p><bold>Keywords:</bold> Arrhythmias, Cardiac / diagnosis; Electrocardiography, Evidence-Based Mediate Ambulatory.</p>
      <p>
        <bold>Introduction</bold>
      </p>
      <p>Ambulatory electrocardiographic monitoring, simply named Holter or 24-hour Holter, is a non-invasive method widely used to assess electrocardiographic abnormalities of patients with various cardiac or non-cardiac diseases, as well as healthy individuals under special conditions or situations. Developed in the 1960s, it underwent great technological advance in recent years. Currently, the recording and storing system used (Holter recorder) is digital, having usually three channels. The device is small (approximately 8.5 x 5.3 x 2.0 cm) and lightweight (45 to 90 grams), being powered by battery, either alkaline or regular. Additional protection against fluid immersion is recommended. Recording is performed with three-channel bipolar electrodes (leads). To mark events, the recorder should have a button, which can be activated by the patient under special conditions, such as the presence of a symptom. </p>
      <p>Since the 1980s, with the evolution of electronic storage, those devices evolved from real-time analysis to storage of digitalized data. Such conditions allowed a large increment in recording reliability, minimizing not only the distortions that can occur in tape recordings, but also the imperfections generated by the mechanical factors inherent in the mechanisms responsible for the rotation of the system. Data analysis has gained in accuracy and details. The 200-Hz frequencies are adequate for the analysis of ST-segment deviations and rhythm disorders. To obtain signal-averaged ECG, 1000-Hz frequencies are required. </p>
      <p>Recently, digital recorders were made available with the option of 12-lead data acquisition, by use of a cable with either ten electrodes or only five electrodes when the orthogonal leads (X, Y, and Z) of vectocardiography are associated. The software generates the electrocardiographic recording with the conventional 12 leads, at any point of the analysis. </p>
      <p>A good quality electrocardiographic recording is fundamental to the usefulness and reliability of the examination proposed, providing the necessary information. When that quality decreases, the amount of information also decreases, while the time for necessary edition increases enormously.</p>
      <p>
        <bold>Clinical application and types of ambulatory electrocardiographic monitoring</bold>
      </p>
      <p>Typically, ambulatory electrocardiographic monitoring is classified according to the monitoring category into continuous and intermittent recordings. Continuous recordings usually occur for 24 hours to 48 hours, while intermittent recordings occur for longer periods of time. The device for intermittent recording, named event recorder, has a memory loop that saves random recordings or those motivated by any clinical symptom. Although there is no clinical study assessing the profile of patients who better benefit from continuous or intermittent recordings, the frequency of the symptoms is the parameter used to choose between both methods. Thus, for patients with sporadic symptoms, the use of the event recorder might be more appropriate, especially for assessing near syncope, syncope and sporadic palpitations<sup>1</sup>. </p>
      <p>The implantable event recorder is available in the market to document infrequent symptoms. It is a small device implanted under the skin of the infraclavicular region, which can maintain circular electrocardiographic monitoring for long periods. </p>
      <p>The use of digital 3-channel 24-hour Holter in clinical practice is aimed at characterizing and diagnosing the occurrence of abnormal electrical cardiac behavior during daily activities (sleep, work, physical exercise, emotional stress, rest). It is mainly, but not exclusively, used for symptomatic or asymptomatic cardiac arrhythmias. However, Holter analysis can also provide the following: ST-segment assessment with or without associated arrhythmias (such as intermittent preexcitation, Brugada-type abnormalities, silent or non-silent ischemia, short or long QT, transient or non-transient abnormality); and autonomous nervous system analysis via heart rate variability<sup>2</sup>. In addition to diagnostic assessment, Holter monitoring can be used to evaluate the efficacy of therapy, both pharmacologic and invasive, for cardiac rhythm disorders and to stratify the risk for sudden death (<xref ref-type="fig" rid="tab01-body2">Box 1</xref>).</p>
      <fig id="tab01-body2">
        <graphic xlink:href="1678-4170-abc-101-02-0101-30164-gf01-en.jpg"/></fig>
      <p>The pattern of beat-to-beat heart rate variability, at baseline or in response to a certain standardized stimulus, can be an objective and non-invasive measure to quantify the autonomic status under physiological and pathological conditions<sup>3</sup>. The analysis techniques most frequently used to determine heart rate variability are obtained in the time and frequency domains.</p>
      <p>Measures in the time domain are usually taken during 24 hours. In such recordings, the QRS complexes are detected, artifacts and ectopic beats being excluded to avoid hindering statistical analyses. The frequency cycles between the QRS complexes are determined and the statistical distributions of all cycles are calculated as mean and standard deviation. The frequency domain analyzes heart rate variability in another way, its principle residing in the fact that every NN interval can be broken into a series of oscillatory components with different frequencies and amplitudes.</p>
      <p><xref ref-type="fig" rid="en_a02tab02-body2">Box 2</xref> shows the major cardiac arrhythmias that can be diagnosed by use of digital 3-channel 24-hour Holter. </p>
      <p content-type="asset">
        <fig id="en_a02tab02-body2">
          <graphic xlink:href="1678-4170-abc-101-02-0101-30164-gf02-en.jpg"/></fig>
      </p>
      <p>
        <bold>Technical aspects of the method</bold>
      </p>
      <p>Although electrode placement may seem to have little significance for Holter monitoring, it is fundamental to a successful procedure. The skin should be properly cleansed with alcohol to remove grease, and then dried before placing the electrodes, which should be pressed in the periphery of their adhesive areas, and not in their centers, to avoid displacing the gel. A good quality electrode is cost-effective, because it guarantees a better tracing quality and less skin irritation. <xref ref-type="fig" rid="en_a02tab03-body2">Box 3</xref> shows the technical recommendations for 24-h Holter monitoring.</p>
      <p content-type="asset">
        <fig id="en_a02tab03-body2">
          <graphic xlink:href="1678-4170-abc-101-02-0101-30164-gf03-en.jpg"/></fig>
      </p>
      <p>Holter should be performed with at least three bipolar channels. If on the one hand an increase in the number of electrodes increases patient's discomfort, on the other, the origin of some arrhythmias can be located with a greater number of leads. Although the cases should be individually considered, in clinical practice, the use of three leads seems to meet the requirement in most situations. </p>
      <p>The choice of the leads should be standardized to allow maximum information regarding morphology and should have good amplitude to avoid failure in heart beat capture. The electrocardiographic channels usually used in Holter monitoring are the modified bipolar leads: V5, V3 and inferior lead<sup>4</sup>.</p>
      <p>The recommended maximum density of artifacts during monitoring is 5%. Greater figures should be analyzed considering the need to repeat the recording. In some cases with spiked T wave, it can be misdetected as a beat, and thus the complex needs to be excluded, causing an overestimated artifact rate that does not interfere with the overall analysis. </p>
      <p>Day-to-day variability in the distribution of arrhythmias is a reality<sup>5-7</sup>. Most clinical studies on arrhythmias uses 24-hour monitoring; however, more prolonged periods or repetition of the monitoring can increase the accuracy of the exam<sup>8</sup>. The Brazilian Society of Cardiac Arrhythmias recommends monitoring for at least 18 hours, including wakefulness and asleep periods, for the analysis and report of ambulatory electrocardiographic monitoring.</p>
      <p>
        <bold>Minimum knowledge and training required to analyze electrocardiographic monitoring tracings</bold>
      </p>
      <p>The professional responsible for analyzing the Holter monitoring, in addition to knowing cardiovascular pathologies, should have a consistent and specific formation in electrocardiography, including cardiac arrhythmias and their differential diagnoses. The correct interpretation of ST-segment deviations, cardiac ischemia and heart rate variability also constitutes a necessary attribute for issuing a Holter report. <xref ref-type="fig" rid="en_a02tab04-body2">Box 4</xref> summarizes the major points of medical knowledge required to assess ambulatory electrocardiographic monitoring.</p>
      <p content-type="asset">
        <fig id="en_a02tab04-body2">
          <graphic xlink:href="1678-4170-abc-101-02-0101-30164-gf04-en.jpg"/></fig>
      </p>
      <p>
        <bold>Proof of competence</bold>
      </p>
      <p>Assessing and interpreting the ambulatory electrocardiographic tracing is a medical act to be performed exclusively by physicians registered in the Regional Board of Medicine, who are apt to professional practice. The Brazilian Society of Cardiac Arrhythmias (Sobrac) recommends that professionals have the specialist title in clinical arrhythmia or electrophysiology with a minimum supervised experience of analyzing 150 tracings<sup>9</sup>, in addition to competence regarding the necessary medical knowledge listed in Box 4.</p>
      <p>
        <bold>Role of the Holter technician</bold>
      </p>
      <p>The performance of a Holter technician at a certain service depends on the preference of the physician in charge. <xref ref-type="fig" rid="en_a02tab05-body2">Box 5</xref> lists the technician's assignments. It is worth noting that the technician is forbidden to act alone without the supervision of a knowledgeable physician according to the recommendations of <xref ref-type="fig" rid="en_a02tab04-body2">Box 4</xref>. </p>
      <p content-type="asset">
        <fig id="en_a02tab05-body2">
          <graphic xlink:href="1678-4170-abc-101-02-0101-30164-gf05-en.jpg"/></fig>
      </p>
      <p>The Holter technician should be trained at official institutions or with an acknowledged professional in the field with a minimum experience of analyzing 1,000 tracings. </p>
      <p>
        <bold>Minimum report in ambulatory electrocardiographic monitoring</bold>
      </p>
      <p>The report should be written in a clear and objective way. The report digital file should be saved for at least five years, preferentially for ten years. The report should comprise the parameters listed in <xref ref-type="fig" rid="en_a02tab06-body2">Box 6</xref>.</p>
      <p content-type="asset">
        <fig id="en_a02tab06-body2">
          <graphic xlink:href="1678-4170-abc-101-02-0101-30164-gf06-en.jpg"/></fig>
      </p>
      <p>
        <bold>Complete list of authors:</bold>
      </p>
      <p>Adalberto Lorga Filho, Fatima Dumas Cintra, Adalberto Lorga, Cesar Grupi, Claudio Pinho, Dalmo Moreira, Dario Sobral, Fabio Sandoli de Brito, Jose Claudio Lupi Krusi, Jose Sobral Neto, Olga Ferreira de Souza, Jos&#233; Tarc&#237;sio Medeiros de Vasconcelos</p>
      <p>
        <bold>Author contributions</bold>
      </p>
      <p>Conception and design of the research: Lorga Filho A, Lorga A; Acquisition of data: Lorga Filho A, Cintra FD; Analysis and interpretation of the data: Cintra FD; Writing of the manuscript: Cintra FD, Grupi C, Pinho C, Moreira D, Sobral Filho DC, Brito FS, Krusi JCL, Sobral Neto J; Critical revision of the manuscript for intellectual content: Lorga Filho A, Cintra FD, Lorga A, Grupi C, Pinho C, Moreira D, Sobral Filho DC, Brito FS, Krusi JCL, Sobral Neto J.</p>
      <p>
        <bold>Potential Conflict of Interest</bold>
      </p>
      <p>No potential conflict of interest relevant to this article was reported.</p>
      <p>
        <bold>Sources of Funding</bold>
      </p>
      <p>There were no external funding sources for this study.</p>
      <p>
        <bold>Study Association</bold>
      </p>
      <p>This study is not associated with any post-graduation program.</p>
      <p>
        <bold>References</bold>
      </p>
    </body>
  </sub-article>
</article>