<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" specific-use="sps-1.9" dtd-version="1.1" xml:lang="pt" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">abc</journal-id>
      <journal-title-group>
        <journal-title>Arquivos Brasileiros de Cardiologia</journal-title>
        <abbrev-journal-title abbrev-type="publisher">Arq. Bras. Cardiol.</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0066-782X</issn>
      <issn pub-type="epub">1678-4170</issn>
      <publisher>
        <publisher-name>Sociedade Brasileira de Cardiologia - SBC</publisher-name>
        <publisher-loc>S&#227;o Paulo, SP, Brazil</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v3">RDHNKfvjhGsFScrbj4gqczt</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v2">S0066-782X2013002700010</article-id>
      <article-id pub-id-type="publisher-id" specific-use="scielo-v1">S0066-782X(13)10100100010</article-id>
      <article-id pub-id-type="doi">10.5935/abc.20130110</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Artigos Originais</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Quantifica&#231;&#227;o da &#225;rea de infarto usando-se SPECT de perfus&#227;o mioc&#225;rdica de alta resolu&#231;&#227;o em ratos</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Oliveira</surname>
            <given-names>Luciano Fonseca Lemos de</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Mejia</surname>
            <given-names>Jorge</given-names>
          </name>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Carvalho</surname>
            <given-names>Eduardo Elias Vieira de</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Lataro</surname>
            <given-names>Renata Maria</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Frassetto</surname>
            <given-names>Sarita Nasbine</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Fazan Jr</surname>
            <given-names>Rubens</given-names>
          </name>
          <xref ref-type="aff" rid="aff03"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Salgado</surname>
            <given-names>H&#233;lio Cesar</given-names>
          </name>
          <xref ref-type="aff" rid="aff03"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Galvis-Alonso</surname>
            <given-names>Orfa Yineth</given-names>
          </name>
          <xref ref-type="aff" rid="aff02"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Sim&#245;es</surname>
            <given-names>Marcus Vin&#237;cius</given-names>
          </name>
          <xref ref-type="aff" rid="aff01"/>
        </contrib>
      </contrib-group>
      <aff id="aff01">
        <addr-line>
          <named-content content-type="city">Ribeir&#227;o Preto</named-content>
          <named-content content-type="state">S&#227;o Paulo</named-content>
        </addr-line>
        <institution content-type="orgname">Universidade de S&#227;o Paulo</institution>
        <institution content-type="orgdiv1">Faculdade de Medicina de Ribeir&#227;o Preto </institution>
        <institution content-type="orgdiv2">Departamento de Cl&#237;nica M&#233;dica</institution>
        <country country="BR">Brazil</country>
      </aff>
      <aff id="aff03">
        <addr-line>
          <named-content content-type="city">Ribeir&#227;o Preto</named-content>
          <named-content content-type="state">S&#227;o Paulo</named-content>
        </addr-line>
        <institution content-type="orgname">Universidade de S&#227;o Paulo</institution>
        <institution content-type="orgdiv1">Faculdade de Medicina de Ribeir&#227;o Preto </institution>
        <institution content-type="orgdiv2">Departamento de Fisiologia</institution>
        <country country="BR">Brazil</country>
      </aff>
      <aff id="aff02">
        <addr-line>
          <named-content content-type="city">S&#227;o Jos&#233; do Rio Preto</named-content>
          <named-content content-type="state">S&#227;o Paulo</named-content>
        </addr-line>
        <institution content-type="orgname">Faculdade de Medicina de S&#227;o Jos&#233; do Rio Preto</institution>
        <institution content-type="orgdiv1">Departamento de Biologia Molecular </institution>
        <country country="BR">Brazil</country>
      </aff>
      <pub-date date-type="collection" publication-format="electronic">
        <month>07</month>
        <year>2013</year>
      </pub-date>
      <volume>101</volume>
      <issue>1</issue>
      <fpage>59</fpage>
      <lpage>67</lpage>
      <history>
        <date date-type="received">
          <day>01</day>
          <month>09</month>
          <year>2012</year>
        </date>
        <date date-type="accepted">
          <day>06</day>
          <month>03</month>
          <year>2013</year>
        </date>
        <date date-type="rev-recd">
          <day>17</day>
          <month>09</month>
          <year>2012</year>
        </date>
      </history>
      <permissions>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/" xml:lang="en">
          <license-p>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</license-p>
        </license>
      </permissions>
      <abstract>
        <p>FUNDAMENTO: T&#233;cnicas de imageamento in vivo permitem avaliar sequencialmente a morfologia e a fun&#231;&#227;o dos &#243;rg&#227;os em diversos modelos experimentais. Desenvolvemos um dispositivo de adapta&#231;&#227;o de uma gama-c&#226;mara cl&#237;nica para obter imagens tomogr&#225;ficas por emiss&#227;o de f&#243;tons singulares (SPECT) de alta resolu&#231;&#227;o, baseado em colimador pinhole. OBJETIVO: Determinar a acur&#225;cia desse sistema na quantifica&#231;&#227;o da &#225;rea de infarto mioc&#225;rdico em ratos. M&#201;TODOS: Treze ratos Wistar machos (250 g) foram submetidos a infarto do mioc&#225;rdio por oclus&#227;o da art&#233;ria coron&#225;ria esquerda. Ap&#243;s 4 semanas, foram adquiridas imagens tomogr&#225;ficas com o sistema desenvolvido, 1,5 hora ap&#243;s a inje&#231;&#227;o endovenosa de 555MBq de 99mTc-Sestamibi. Na reconstru&#231;&#227;o tomogr&#225;fica, utilizamos software especialmente desenvolvido baseado no algoritmo de M&#225;xima Verossimilhan&#231;a. Comparamos as m&#233;dias e analisamos a correla&#231;&#227;o entre a extens&#227;o dos defeitos perfusionais detectados pela cintilografia e a extens&#227;o da fibrose mioc&#225;rdica avaliada pela histologia. RESULTADOS: As imagens apresentaram &#243;tima rela&#231;&#227;o &#243;rg&#227;o-alvo/fundo, com apropriada visualiza&#231;&#227;o das paredes e da cavidade do ventr&#237;culo esquerdo. Todos os animais exibindo &#225;reas de infarto foram corretamente identificados pelas imagens de perfus&#227;o. N&#227;o houve diferen&#231;a entre a &#225;rea do infarto medida pelo SPECT (21,1 &#177; 21,2%) e pela histologia (21,7 &#177; 22,0%; p = 0,45), obtendo forte correla&#231;&#227;o entre os valores da &#225;rea de infarto mensurada pelos dois m&#233;todos (r = 0,99; p &lt; 0,0001). CONCLUS&#195;O: O sistema desenvolvido apresentou resolu&#231;&#227;o espacial adequada e elevada acur&#225;cia para detec&#231;&#227;o e quantifica&#231;&#227;o das &#225;reas de infarto mioc&#225;rdico, sendo uma op&#231;&#227;o de baixo custo e grande versatilidade na obten&#231;&#227;o de imagens em SPECT de alta resolu&#231;&#227;o de &#243;rg&#227;os de pequenos roedores.</p>
      </abstract>
      <kwd-group xml:lang="pt" kwd-group-type="author-generated">
        <kwd>Infarto do Mioc&#225;rdio</kwd>
        <kwd>Ratos</kwd>
        <kwd>Tomografia Computadorizada de Emiss&#227;o</kwd>
        <kwd>Epidemiologia Experimental</kwd>
      </kwd-group>
      <pub-date publication-format="electronic" date-type="pub">
        <day>31</day>
        <month>07</month>
        <year>2013</year>
      </pub-date>
    </article-meta>
  </front>
  <body>
    <p>
      <bold>ARTIGO ORIGINAL</bold>
    </p>
    <p>
      <bold>Quantifica&#231;&#227;o da &#225;rea de infarto usando-se SPECT de perfus&#227;o mioc&#225;rdica de alta resolu&#231;&#227;o em ratos</bold>
    </p>
    <p>
      <bold>Luciano Fonseca Lemos de Oliveira<sup>I</sup>; Jorge Mejia<sup>II</sup>; Eduardo Elias Vieira de Carvalho<sup>I</sup>; Renata Maria Lataro<sup>I</sup>; Sarita Nasbine Frassetto<sup>I</sup>; Rubens Fazan Jr<sup>III</sup>; H&#233;lio Cesar Salgado<sup>III</sup>; Orfa Yineth Galvis-Alonso<sup>II</sup>; Marcus Vin&#237;cius Sim&#245;es<sup>I</sup></bold>
    </p>
    <p><sup>I</sup>Divis&#227;o de Cardiologia, Departamento de Cl&#237;nica M&#233;dica, Faculdade de Medicina de Ribeir&#227;o Preto, Universidade de S&#227;o Paulo, Ribeir&#227;o Preto, SP </p>
    <p><sup>II</sup>Departamento de Biologia Molecular, Faculdade de Medicina de S&#227;o Jos&#233; do Rio Preto, S&#227;o Jos&#233; do Rio Preto, SP</p>
    <p> IIIDepartamento de Fisiologia, Faculdade de Medicina de Ribeir&#227;o Preto, Universidade de S&#227;o Paulo, Ribeir&#227;o Preto, SP - Brasil </p>
    <p>
      <xref ref-type="corresp" rid="end">Correspond&#234;ncia</xref>
    </p>
    <p>
      <bold>RESUMO</bold>
    </p>
    <p><bold>FUNDAMENTO:</bold> T&#233;cnicas de imageamento <italic>in vivo</italic> permitem avaliar sequencialmente a morfologia e a fun&#231;&#227;o dos &#243;rg&#227;os em diversos modelos experimentais. Desenvolvemos um dispositivo de adapta&#231;&#227;o de uma gama-c&#226;mara cl&#237;nica para obter imagens tomogr&#225;ficas por emiss&#227;o de f&#243;tons singulares (SPECT) de alta resolu&#231;&#227;o, baseado em colimador pinhole. </p>
    <p><bold>OBJETIVO:</bold> Determinar a acur&#225;cia desse sistema na quantifica&#231;&#227;o da &#225;rea de infarto mioc&#225;rdico em ratos. </p>
    <p><bold>M&#201;TODOS: </bold>Treze ratos Wistar machos (250 g) foram submetidos a infarto do mioc&#225;rdio por oclus&#227;o da art&#233;ria coron&#225;ria esquerda. Ap&#243;s 4 semanas, foram adquiridas imagens tomogr&#225;ficas com o sistema desenvolvido, 1,5 hora ap&#243;s a inje&#231;&#227;o endovenosa de 555MBq de <sup>99m</sup>Tc-Sestamibi. Na reconstru&#231;&#227;o tomogr&#225;fica, utilizamos <italic>software</italic> especialmente desenvolvido baseado no algoritmo de M&#225;xima Verossimilhan&#231;a. Comparamos as m&#233;dias e analisamos a correla&#231;&#227;o entre a extens&#227;o dos defeitos perfusionais detectados pela cintilografia e a extens&#227;o da fibrose mioc&#225;rdica avaliada pela histologia. </p>
    <p><bold>RESULTADOS:</bold> As imagens apresentaram &#243;tima rela&#231;&#227;o &#243;rg&#227;o-alvo/fundo, com apropriada visualiza&#231;&#227;o das paredes e da cavidade do ventr&#237;culo esquerdo. Todos os animais exibindo &#225;reas de infarto foram corretamente identificados pelas imagens de perfus&#227;o. N&#227;o houve diferen&#231;a entre a &#225;rea do infarto medida pelo SPECT (21,1 &#177; 21,2%) e pela histologia (21,7 &#177; 22,0%; p = 0,45), obtendo forte correla&#231;&#227;o entre os valores da &#225;rea de infarto mensurada pelos dois m&#233;todos (r = 0,99; p &lt; 0,0001). </p>
    <p><bold>CONCLUS&#195;O:</bold> O sistema desenvolvido apresentou resolu&#231;&#227;o espacial adequada e elevada acur&#225;cia para detec&#231;&#227;o e quantifica&#231;&#227;o das &#225;reas de infarto mioc&#225;rdico, sendo uma op&#231;&#227;o de baixo custo e grande versatilidade na obten&#231;&#227;o de imagens em SPECT de alta resolu&#231;&#227;o de &#243;rg&#227;os de pequenos roedores. </p>
    <p><bold>Palavras-chave:</bold> Infarto do Mioc&#225;rdio, Ratos, Tomografia Computadorizada de Emiss&#227;o, Epidemiologia Experimental.</p>
    <p>
      <bold>Introdu&#231;&#227;o</bold>
    </p>
    <p>Nas &#250;ltimas d&#233;cadas, animais de laborat&#243;rio tornaram-se importante ferramenta em pesquisas pr&#233;-cl&#237;nicas<sup>1</sup>. Em cardiologia, pequenos animais t&#234;m sido usados com sucesso para reprodu&#231;&#227;o de diversos modelos de cardiopatias e seus resultados t&#234;m permitido o estudo de novas drogas, assim como os estudos dos mecanismos fisiopatol&#243;gicos de doen&#231;as card&#237;acas<sup>2-5</sup>.</p>
    <p>Na explora&#231;&#227;o desses modelos animais, apesar de muitas vari&#225;veis experimentais poderem ser avaliadas <italic>in vivo</italic>, na maioria dos casos o animal deve ser sacrificado e o &#243;rg&#227;o de interesse deve ser excisado e processado para obten&#231;&#227;o dos resultados. Esse processo elimina a possibilidade de avalia&#231;&#245;es m&#250;ltiplas ao longo do tempo. Entretanto, o desenvolvimento recente de t&#233;cnicas para a aquisi&#231;&#227;o de imagens <italic>in vivo</italic> em pequenos animais passou a permitir a avalia&#231;&#227;o sequencial da estrutura e da fun&#231;&#227;o de &#243;rg&#227;os de forma n&#227;o invasiva, com economia de tempo, n&#250;mero de animais e redu&#231;&#227;o de custos. </p>
    <p>Os equipamentos de uso cl&#237;nico, baseados na ultrassonografia e na resson&#226;ncia nuclear magn&#233;tica, exibem sensibilidade e resolu&#231;&#227;o espacial suficientes para obten&#231;&#227;o de imagens de &#243;rg&#227;os de pequenos animais, que s&#227;o, em m&#233;dia, 10 a 30 vezes menores em dimens&#245;es lineares do que os &#243;rg&#227;os de seres humanos. Contudo, os equipamentos cl&#237;nicos convencionais utilizados para obten&#231;&#227;o de imagens cintilogr&#225;ficas tomogr&#225;ficas por emiss&#227;o de f&#243;tons singulares (SPECT) fornecem uma resolu&#231;&#227;o espacial em torno de 6 mm, n&#227;o apropriada para &#243;rg&#227;os de pequenos animais, cuja resolu&#231;&#227;o espacial necess&#225;ria &#233; em torno de 1 mm.</p>
    <p>Nosso grupo de pesquisa recentemente descreveu a implementa&#231;&#227;o de um sistema de aquisi&#231;&#227;o de imagens de SPECT de alta resolu&#231;&#227;o baseado em um colimador pinhole (&#250;nico orif&#237;cio), um sistema rotacional de suporte do pequeno animal e ferramentas de <italic>software</italic> apropriadas adaptadas a uma gama-c&#226;mara de uso cl&#237;nico<sup>6,7</sup>. O objetivo do presente estudo foi validar esse sistema para quantifica&#231;&#227;o <italic>in vivo</italic> da &#225;rea de fibrose mioc&#225;rdica em modelo experimental de infarto em ratos, tendo como padr&#227;o-ouro a medida <italic>in vitro </italic>da &#225;rea de infarto pelo estudo histopatol&#243;gico.</p>
    <p>
      <bold>M&#233;todos</bold>
    </p>
    <p>
      <bold>Constru&#231;&#227;o e adapta&#231;&#227;o do sistema de aquisi&#231;&#227;o de imagens tomogr&#225;ficas</bold>
    </p>
    <p>Uma gama-c&#226;mara cl&#237;nica (DST/Sopha Medical Vision, Twinsburg, Ohio, USA) foi adaptada pela constru&#231;&#227;o de um sistema de blindagem que permitiu a fixa&#231;&#227;o de um colimador de orif&#237;cio simples, com di&#226;metro de 1,5 mm e &#226;ngulo de abertura total de 150&#186;. Essa blindagem teve um formato de tronco de pir&#226;mide recoberta com uma manta de chumbo de 6 mm de espessura, adequada para f&#243;tons com energia na faixa de 150 keV. Adicionalmente, foi desenvolvido um suporte cil&#237;ndrico para o posicionamento do animal. Esse suporte &#233; acoplado a um sistema motorizado, que permitiu rotacionar o alvo para as diferentes posi&#231;&#245;es angulares, de acordo com o n&#250;mero de proje&#231;&#245;es a serem registradas ao longo dos 360&#186;da aquisi&#231;&#227;o tomogr&#225;fica. Sincronizada com o protocolo de aquisi&#231;&#227;o din&#226;mico da gama-c&#226;mara, a sequ&#234;ncia de proje&#231;&#245;es foi registrada e armazenada em formato DICOM. Na <xref ref-type="fig" rid="a10fig01">Figura 1</xref>, ilustramos o conjunto do <italic>hardware</italic> constru&#237;do. </p>
    <p content-type="asset">
      <fig id="a10fig01">
        <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf01.jpg"/></fig>
    </p>
    <p>
      <bold>Implementa&#231;&#227;o do software de reconstru&#231;&#227;o</bold>
    </p>
    <p>Ap&#243;s a aquisi&#231;&#227;o das proje&#231;&#245;es, as imagens gravadas foram exportadas em formato DICOM para um computador pessoal, no qual foram processadas para obten&#231;&#227;o do modelo tridimensional da distribui&#231;&#227;o do radiof&#225;rmaco no alvo<sup>7</sup>. Para isso, desenvolvemos um <italic>software</italic> de reconstru&#231;&#245;es iterativas de imagens, baseado no algoritmo de M&#225;xima Verossimilhan&#231;a<sup>8</sup>. Os detalhes matem&#225;ticos dos c&#225;lculo de reconstru&#231;&#227;o iterativa podem ser consultados em publica&#231;&#227;o anterior<sup>7</sup>. Ainda que a reconstru&#231;&#227;o iterativa seja mais lenta do que o algoritmo cl&#225;ssico de retroproje&#231;&#227;o filtrada, ela produz imagens de melhor qualidade, em termos de rela&#231;&#227;o sinal-ru&#237;do e resolu&#231;&#227;o espacial, e permite uma melhor modelagem do processo f&#237;sico envolvido durante a aquisi&#231;&#227;o das imagens<sup>9,10</sup>. A ferramenta foi implementada em Linguagem C, usando um compilador <italic>freeware</italic> Dev-C++ (Bloodshed Software). Para visualiza&#231;&#227;o final das reconstru&#231;&#245;es, foi utilizado o <italic>freeware</italic> Amide Medical Image Data Examiner<sup>11</sup>.</p>
    <p>
      <bold>Imagens de fantoma</bold>
    </p>
    <p>A fim de verificar a resolu&#231;&#227;o espacial tomogr&#225;fica alcan&#231;ada pelo sistema, foram adquiridas imagens de um fantoma de barras quentes. Esse fantoma consiste de quatro conjuntos de espa&#231;os cil&#237;ndricos de diferentes di&#226;metros (1, 2, 3 e 4 mm), preenchidos com pertecnetato de s&#243;dio, sendo a dist&#226;ncia entre eles igual ao dobro do seu di&#226;metro (<xref ref-type="fig" rid="a10fig02a_b">Figura 2A</xref>). Na aquisi&#231;&#227;o das imagens do fantoma, foram utilizados os mesmos par&#226;metros empregados para a aquisi&#231;&#227;o de imagens dos animais experimentais.</p>
    <p content-type="asset">
      <fig id="a10fig02a_b">
        <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf02.jpg"/></fig>
    </p>
    <p>
      <bold>Animais experimentais</bold>
    </p>
    <p>Ap&#243;s aprova&#231;&#227;o da Comiss&#227;o de &#201;tica em Experimenta&#231;&#227;o Animal de nossa institui&#231;&#227;o , os experimentos foram realizados com 15 ratos Wistar machos com peso inicial de 250g. Os animais foram fornecidos pelo biot&#233;rio central da mesma institui&#231;&#227;o, mantidos em alojamento climatizado, com acesso livre a &#225;gua e ra&#231;&#227;o padr&#227;o, submetidos a ritmo de 12 horas de luz/sombra e temperatura controlada. Em todos os procedimentos, m&#225;ximo esfor&#231;o foi feito para evitar o sofrimento desnecess&#225;rio nos animais.</p>
    <p>
      <bold>Indu&#231;&#227;o do infarto do mioc&#225;rdio experimental</bold>
    </p>
    <p>O infarto mioc&#225;rdico experimental foi induzido em 13 animais pelo m&#233;todo descrito por Pfeffer e cols.<sup>12</sup>, com ligeiras modifica&#231;&#245;es. Dois animais foram mantidos como controles n&#227;o infartados. Os procedimentos cir&#250;rgicos foram realizados sob anestesia k etamina (50 mg/kg, i.m., Uni&#227;o Qu&#237;mica Farmac&#234;utica Nacional S/A, Embu-Gua&#231;u, SP, Brasil) e xilazina (10 mg/kg, i.m., HertapeCalier Sa&#250;de Animal S/A, Juatuba, MG, Brasil) e intuba&#231;&#227;o orotraqueal para ventila&#231;&#227;o mec&#226;nica (Advanced Safety Ventilator, Harvard Apparatus, MA1 55-7059, Holliston, MA, USA). Assim, o cora&#231;&#227;o foi exposto por uma incis&#227;o no terceiro espa&#231;o intercostal esquerdo, e o ramo descendente anterior da art&#233;ria coron&#225;ria esquerda foi identificado e ligado com um fio de poli&#233;ster (4-0, Ethicon, S&#227;o Jos&#233; dos Campos, SP, Brasil). Em seguida, o t&#243;rax foi fechado e os animais levados para recupera&#231;&#227;o no Biot&#233;rio do Departamento de Fisiologia de nossa institui&#231;&#227;o . </p>
    <p>
      <bold>Aquisi&#231;&#227;o de imagens de perfus&#227;o mioc&#225;rdica</bold>
    </p>
    <p>Os animais foram submetidos aos exames de imagem 4 semanas ap&#243;s a indu&#231;&#227;o do infarto mioc&#225;rdico experimental. Para o protocolo de imagens, os animais foram anestesiados com uma combina&#231;&#227;o de ketamina e xilazina (50 e 5 mg/kg, respectivamente). Uma atividade de 555 MBq de 99mTc-Sestamibi foi injetada na veia da cauda. Uma hora e meia ap&#243;s a inje&#231;&#227;o, os animais foram novamente anestesiados com ketamina e xilazina (75 e 7,5 mg/kg, respectivamente) e posicionados no sistema para a aquisi&#231;&#227;o de imagens.</p>
    <p>Trinta e seis proje&#231;&#245;es, igualmente espa&#231;adas em 360&#186;, foram adquiridas em todos os protocolos de imagens. As proje&#231;&#245;es foram registradas em uma matriz de 128 x 128 elementos, cada elemento com uma &#225;rea de 3,4 mm x 3,4mm. Um fator de magnifica&#231;&#227;o de 6,3X foi adotado para todos os experimentos, o que corresponde a uma dimens&#227;o lateral de elemento do volume do objeto (ou <italic>voxel</italic>) de 0,54 mm. O tempo de aquisi&#231;&#227;o por proje&#231;&#227;o foi de 30 segundos, totalizando aproximadamente 21 minutos por animal.</p>
    <p>N&#227;o se registrou mortalidade associada &#224; realiza&#231;&#227;o dessas imagens na janela temporal de 4 semanas ap&#243;s infarto.</p>
    <p>
      <bold>Processamento e an&#225;lise das imagens de perfus&#227;o mioc&#225;rdica</bold>
    </p>
    <p>Ap&#243;s a reconstru&#231;&#227;o das imagens de SPECT utilizando-se algoritmo de reconstru&#231;&#227;o iterativa, a imagem foi apropriadamente rotacionada e foram selecionados cortes tomogr&#225;ficos dos eixos curto, longo vertical e longo horizontal. As imagens foram normalizadas para o <italic>pixel</italic> mioc&#225;rdico de m&#225;ximo valor de capta&#231;&#227;o dentro do volume e submetidas &#224; an&#225;lise visual. </p>
    <p>Para quantifica&#231;&#227;o do defeito perfusional nas imagens de SPECT, foram utilizados quatro cortes tomogr&#225;ficos do eixo curto em diferentes n&#237;veis da cavidade ventricular esquerda: um corte apical, dois cortes m&#233;dio-ventriculares e um corte basal. Utilizando o <italic>freeware</italic> de processamento de imagens ImageJ, foi determinado perfil de intensidade ao longo da circunfer&#234;ncia do mioc&#225;rdio do ventr&#237;culo esquerdo (VE). As &#225;reas de defeito perfusional foram identificadas pela presen&#231;a de <italic>pixels</italic> com valores de capta&#231;&#227;o abaixo de 50% em rela&#231;&#227;o ao <italic>pixel</italic> de m&#225;ximo ac&#250;mulo de capta&#231;&#227;o no mioc&#225;rdio. A extens&#227;o total do defeito perfusional mioc&#225;rdico foi expresso como percentual de &#225;rea do VE, sendo calculada pela raz&#227;o do n&#250;mero total dos <italic>pixels</italic> com capta&#231;&#227;o menor que 50% (obtidos nos quatro cortes) pelo n&#250;mero total de <italic>pixels</italic> compondo o perfil circunferencial do VE nos quatro cortes tomogr&#225;ficos analisados, sendo esse resultado multiplicado por cem. </p>
    <p>Um &#250;nico investigador, velado quanto aos resultados da an&#225;lise histol&#243;gica, foi respons&#225;vel pelo processamento quantitativo das imagens.</p>
    <p>
      <bold>Histologia</bold>
    </p>
    <p>Para an&#225;lise histopatol&#243;gica ap&#243;s a eutan&#225;sia, o cora&#231;&#227;o foi rapidamente excisado e fixado em formalde&#237;do a 10%, por 24 horas, e, depois, transferido para &#225;lcool 70%. As amostras foram progressivamente desidratadas e embebidas em parafina. Cortes histol&#243;gicos foram produzidos seguindo-se plano de corte perpendicular ao longo eixo do cora&#231;&#227;o, de forma a reproduzir os cortes em eixo curto obtidos nos estudos de perfus&#227;o mioc&#225;rdica <italic>in vivo. </italic>Esses cortes foram corados com tricr&#244;mico de Masson para perfeita identifica&#231;&#227;o das &#225;reas de fibrose, que ficam coradas em azul.</p>
    <p>Para quantifica&#231;&#227;o da &#225;rea de fibrose nos estudos histol&#243;gicos, procedeu-se de forma semelhante ao descrito para os cortes tomogr&#225;ficos dos estudos de perfus&#227;o <italic>in vivo</italic>. Resumidamente, as imagens correspondentes aos quatro n&#237;veis de corte da cavidade ventricular esquerda foram digitalizadas mediante emprego de um esc&#226;ner. Um perfil circunferencial acompanhando a conforma&#231;&#227;o das paredes do VE foi delineado utilizando-se o programa ImageJ, sendo computada a extens&#227;o linear da circunfer&#234;ncia do VE em cada corte. Tamb&#233;m foi identificada e quantificada, em cada corte, a extens&#227;o linear do tecido mioc&#225;rdico corado como fibrose. A extens&#227;o da fibrose mioc&#225;rdica, expressa em percentual da &#225;rea da superf&#237;cie do VE foi calculada pela divis&#227;o da extens&#227;o total do tecido fibr&#243;tico nos quatro cortes, dividida pela extens&#227;o total das circunfer&#234;ncias do VE em todos os quatro cortes, sendo o valor final multiplicado por cem.</p>
    <p>Um &#250;nico investigador realizou a quantifica&#231;&#227;o das &#225;reas de fibrose nos estudos histol&#243;gicos, estando velado quanto aos resultados obtidos nas imagens <italic>in vivo.</italic></p>
    <p>
      <bold>An&#225;lise estat&#237;stica</bold>
    </p>
    <p>Os resultados foram expressos na forma de m&#233;dia e desvio padr&#227;o da m&#233;dia. A distribui&#231;&#227;o Gaussiana das vari&#225;veis foi verificada mediante emprego do teste de Kolmogorov-Smirnov. Para compara&#231;&#227;o entre os valores m&#233;dios da extens&#227;o da fibrose mioc&#225;rdica entre o m&#233;todo <italic>in vivo</italic> e a histologia, foi utilizado o teste <italic>t</italic> de Student pareado. Para an&#225;lise de correla&#231;&#227;o entre os resultados individuais obtidos em cada um dos m&#233;todos, foi utilizado o teste de regress&#227;o linear e correla&#231;&#227;o pelo m&#233;todo dos m&#237;nimos quadrados. O m&#233;todo gr&#225;fico de Bland-Altman foi utilizado para an&#225;lise adicional da concord&#226;ncia entre as medidas da &#225;rea de fibrose obtidas pelos dois m&#233;todos empregados. </p>
    <p>
      <bold>Resultados</bold>
    </p>
    <p>
      <bold>Resolu&#231;&#227;o espacial das imagens tomogr&#225;ficas</bold>
    </p>
    <p>A <xref ref-type="fig" rid="a10fig02a_b">Figura 2B</xref> mostra imagens tomogr&#225;ficas reconstru&#237;das dos cortes transversais, em sec&#231;&#227;o perpendicular ao longo eixo, das barras preenchidas com radioatividade do fantoma micro-Jasczak. Numa an&#225;lise visual semiquantitativa, &#233; poss&#237;vel identificar-se, com nitidez, o contorno das barras do grupo com di&#226;metro internos de 2 mm, perdendo-se a resolu&#231;&#227;o das imagens no grupo de barras com di&#226;metro interno de 1 mm, sugerindo que o limite da resolu&#231;&#227;o espacial se encontre entre os valores de 1 e 2 mm. Uma determina&#231;&#227;o mais precisa da resolu&#231;&#227;o espacial foi obtida pela an&#225;lise de um perfil de contagens de uma fonte linear (PSF), que resultou em uma resolu&#231;&#227;o espacial de 1,5 mm (largura &#224; meia altura). O tamanho do <italic>pixel </italic>no objeto imageado foi de 0,6 mm.</p>
    <p>
      <bold>An&#225;lise visual das imagens de perfus&#227;o mioc&#225;rdica</bold>
    </p>
    <p>A <xref ref-type="fig" rid="a10fig03">Figura 3</xref> apresenta imagens do SPECT de perfus&#227;o mioc&#225;rdica de um dos animais controles, utilizados para padroniza&#231;&#227;o inicial da visualiza&#231;&#227;o das imagens. Observou-se elevada rela&#231;&#227;o de contagens &#243;rg&#227;o-alvo/fundo com nitidez os limites das paredes e o delineamento da cavidade do VE, al&#233;m da visualiza&#231;&#227;o das paredes do ventr&#237;culo direito em alguns cortes m&#233;dio-cavit&#225;rios. As imagens do animal controle apresentam distribui&#231;&#227;o uniforme do radiotra&#231;ador entre os diferentes seguimentos mioc&#225;rdicos, com exce&#231;&#227;o do &#225;pice que apresentou uma menor intensidade de capta&#231;&#227;o, que foi atribu&#237;da ao afilamento parietal da regi&#227;o apical. Entretanto, esses valores n&#227;o estiveram abaixo de 50% em rela&#231;&#227;o ao <italic>pixel</italic> de m&#225;ximo ac&#250;mulo de capta&#231;&#227;o no mioc&#225;rdio.</p>
    <p content-type="asset">
      <fig id="a10fig03">
        <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf03.jpg"/></fig>
    </p>
    <p>A qualidade das imagens dos animais infartados (<xref ref-type="fig" rid="a10fig04">Figura 4</xref>) &#233; compar&#225;vel com a dos animais controles; al&#233;m disso, evidenciou-se claramente o defeito de capta&#231;&#227;o em territ&#243;rios compat&#237;veis com &#225;reas de irriga&#231;&#227;o da art&#233;ria coron&#225;ria esquerda do rato (parede anterior, anterolateral e regi&#227;o apical) em todos os animais, com &#225;reas significativas de infarto confirmadas na histologia. </p>
    <p content-type="asset">
      <fig id="a10fig04">
        <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf04.jpg"/></fig>
    </p>
    <p>
      <bold>An&#225;lise quantitativa das &#225;reas de infarto mioc&#225;rdico</bold>
    </p>
    <p>Na <xref ref-type="fig" rid="a10fig05">Figura 5</xref>, podemos comparar as imagens tomogr&#225;ficas do SPECT de perfus&#227;o mioc&#225;rdica dos cortes com as imagens correspondentes do estudo histol&#243;gico, usadas para quantifica&#231;&#227;o do defeito perfusional e &#225;rea de fibrose, respectivamente. Nota-se grande semelhan&#231;a da morfologia das paredes assim como a topografia e a extens&#227;o do defeito perfusional mioc&#225;rdico mostrado nas imagens de SPECT e nos cortes histol&#243;gicos.</p>
    <p content-type="asset">
      <fig id="a10fig05">
        <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf05.jpg"/></fig>
    </p>
    <p>A &#225;rea de infarto mioc&#225;rdico quantificada pela histologia foi de 21,7 &#177; 22,0% da superf&#237;cie do VE. O tamanho da &#225;rea de infarto mioc&#225;rdico apresentou grande varia&#231;&#227;o individual entre os animais, com extremos de 26,5 a 55,0%, sendo que seis animais n&#227;o apresentaram &#225;rea significativa de fibrose no estudo histopatol&#243;gico. </p>
    <p>Todos os animais exibindo &#225;reas significativas de fibrose mioc&#225;rdica no estudo histol&#243;gico foram corretamente identificados pela presen&#231;a de defeitos de capta&#231;&#227;o no SPECT de perfus&#227;o mioc&#225;rdica. A &#225;rea da superf&#237;cie do VE exibindo defeito de capta&#231;&#227;o detectado no SPECT de perfus&#227;o mioc&#225;rdica (&#225;rea de infarto) foi 21,1 &#177; 21,2% (extremos de 30,0 a 50,0%), resultados estes semelhantes ao obtido no estudo histol&#243;gico (p=0,45).</p>
    <p>Mediante an&#225;lise de regress&#227;o linear, obteve-se excelente correla&#231;&#227;o entre os valores individuais da extens&#227;o do defeito de capta&#231;&#227;o mioc&#225;rdica pelo SPECT e a extens&#227;o da fibrose mioc&#225;rdica pela histologia (n = 13, r = 0,99; p &lt; 0,0001). Observa-se, no gr&#225;fico de dispers&#227;o, que a linha de regress&#227;o exibe um slope = 1,03, mostrando-se quase superpon&#237;vel &#224; reta de identidade entre os resultados (<xref ref-type="fig" rid="a10fig06">Figura 6</xref>). </p>
    <p content-type="asset">
      <fig id="a10fig06">
        <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf06.jpg"/></fig>
    </p>
    <p>A plotagem dos dados seguindo-se o m&#233;todo gr&#225;fico de an&#225;lise de concord&#226;ncia entre medidas de Bland-Altman (<xref ref-type="fig" rid="a10fig07">Figura 7</xref>) mostrou elevada concord&#226;ncia entre os resultados obtidos pelos dois m&#233;todos. Como se observa no gr&#225;fico, a m&#233;dia das diferen&#231;as entre as medidas foi de -0,6, valor muito pr&#243;ximo ao zero (valor ideal). Os valores individuais das diferen&#231;as entre as medidas distribuem-se em estreita faixa em torno da m&#233;dia, situando-se entre as barras representativas de 2 desvios padr&#227;o, demonstrando que o limite de varia&#231;&#227;o para a diferen&#231;a entre as medidas foi bastante aceit&#225;vel (&#177;5,4 pontos percentuais).</p>
    <p content-type="asset">
      <fig id="a10fig07">
        <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf07.jpg"/></fig>
    </p>
    <p>
      <bold>Discuss&#227;o</bold>
    </p>
    <p>Neste estudo, descrevemos um sistema para obten&#231;&#227;o de imagens cintilogr&#225;ficas em SPECT de alta resolu&#231;&#227;o para pequenos animais, baseado num colimador pinhole acoplado a um suporte rotacional, adaptados a uma gama-c&#226;mara cl&#237;nica. No melhor do nosso conhecimento, este &#233; o primeiro dispositivo dessa natureza desenvolvido na Am&#233;rica Latina. O desempenho desse sistema permitiu identificar estruturas entre 1 e 2 mm, atingindo uma resolu&#231;&#227;o espacial de 1,5 mm (FWHM) com um tamanho de <italic>pixel</italic> de 0,6 mm. Esses valores s&#227;o semelhantes aos reportados em outros estudos, descrevendo sistemas adaptados em gama-c&#226;mara cl&#237;nica<sup>13-15</sup> e sistemas especialmente constru&#237;dos para pequenos animais<sup>16-18</sup>.</p>
    <p>Al&#233;m de elevada resolu&#231;&#227;o espacial, as imagens de SPECT de perfus&#227;o mioc&#225;rdica obtidas dos animais, tanto controles quanto infartados, apresentaram qualidade compar&#225;veis &#224;s das imagens obtidas em humanos, com visualiza&#231;&#227;o apropriada das paredes e da cavidade ventricular esquerda, al&#233;m da visualiza&#231;&#227;o da parede do ventr&#237;culo direito em alguns cortes, com elevada rela&#231;&#227;o de contagens &#243;rg&#227;o-alvo/fundo. </p>
    <p>Quando comparadas ao histopatol&#243;gico, as imagens de SPECT de perfus&#227;o mioc&#225;rdica dos animais submetidos ao infarto experimental apresentaram grande semelhan&#231;a na morfologia das paredes, assim como na topografia da &#225;rea de infarto. Adicionalmente, a extens&#227;o do defeito perfusional mioc&#225;rdico apresentou uma forte correla&#231;&#227;o com a &#225;rea de infarto medido pela histologia. Nossos resultados, em rela&#231;&#227;o &#224; acur&#225;cia na quantifica&#231;&#227;o da extens&#227;o da &#225;rea de infarto, s&#227;o compar&#225;veis &#224;queles relatados por outros estudos utilizando ratos e camundongos em outros sistemas de imagens cintilogr&#225;ficas de alta resolu&#231;&#227;o<sup>13,14,18-20</sup>. Esses aspectos sugerem, no conjunto, que o sistema desenvolvido tem desempenho e acur&#225;cia compar&#225;veis aos de sistemas dedicados comercialmente dispon&#237;veis.</p>
    <p>Um sistema de aquisi&#231;&#227;o de arquitetura aberta, como o descrito aqui, mostra-se bastante vers&#225;til, pois, al&#233;m de ser facilmente acoplado a outras gama-c&#226;maras, pequenas mudan&#231;as em sua configura&#231;&#227;o permitem a realiza&#231;&#227;o de imagens de animais de diferentes tamanhos, variando de 30 a 800 g. Essas mudan&#231;as consistem na substitui&#231;&#227;o do suporte rotacional por outros de diferentes calibres e no ajuste da dist&#226;ncia entre o animal a ser estudado e o orif&#237;cio do pinhole, promovendo diferentes magnifica&#231;&#245;es do objeto imageado. Essa versatilidade permite ainda ajustes para otimiza&#231;&#227;o dos par&#226;metros de aquisi&#231;&#227;o de diferentes modalidades de estudos cintilogr&#225;ficos card&#237;acos no mesmo animal (por exemplo: ventriculografia nuclear planar e tomogr&#225;fica e gated-SPECT de perfus&#227;o) e possibilidade de imagens funcionais de diferentes &#243;rg&#227;os (por exemplo: c&#233;rebro, rim, tireoide e pulm&#227;o). Al&#233;m disso, quando comparado a sistemas dedicados a pequenos animais comercialmente dispon&#237;veis para obten&#231;&#227;o de imagens de SPECT, o sistema descrito aqui exibe custos de constru&#231;&#227;o incomparavelmente menores. O investimento em material e m&#227;o de obra especializada empregados para a montagem f&#237;sica do sistema descrito aqui foi de aproximadamente R$10.000,00. O desenvolvimento do <italic>software</italic> de reconstru&#231;&#227;o empregou plataformas de acesso livre e os algoritmos e f&#243;rmulas matem&#225;ticas que fundamentam o programa foram publicados anteriormente<sup>7</sup>.</p>
    <p>Alguns aspectos t&#233;cnicos adicionais devem ser apresentados para se explicarem as vantagens da configura&#231;&#227;o desse tipo de sistema de aquisi&#231;&#227;o de imagens, em que o alvo (pequeno animal) &#233; girado em frente ao detector. Imagens de SPECT s&#227;o baseadas na aquisi&#231;&#227;o de um conjunto de imagens planares (proje&#231;&#245;es) em diferentes &#226;ngulos ao redor do objeto. No cen&#225;rio cl&#237;nico, as proje&#231;&#245;es geralmente s&#227;o obtidas por colimadores paralelos, sendo que a cabe&#231;a do detector gira em &#243;rbita circunferencial em torno do paciente, resultando em imagens com uma resolu&#231;&#227;o espacial de aproximadamente 6 mm (largura &#224; meia altura)<sup>21</sup>. Para imagens de &#243;rg&#227;os de pequenos animais, &#233; tecnicamente mais vantajoso girarmos o animal, para obten&#231;&#227;o das proje&#231;&#245;es, e n&#227;o o detector. Dessa forma, a maioria dos desalinhamentos e oscila&#231;&#245;es causadas pela movimenta&#231;&#227;o da cabe&#231;a do detector da gama-c&#226;mara s&#227;o eliminados, bem como s&#227;o minimizados o custo de constru&#231;&#227;o e o espa&#231;o de opera&#231;&#227;o do sistema.</p>
    <p>Diferentemente do que acontece quando se empregam colimadores de orif&#237;cios paralelos, h&#225; um fator de magnifica&#231;&#227;o impl&#237;cito no uso do colimador pinhole. Essa magnifica&#231;&#227;o &#233; uma fun&#231;&#227;o da rela&#231;&#227;o das dist&#226;ncias entre o detector e o colimador e entre o objeto-alvo e o colimador. Quanto mais pr&#243;ximo do orif&#237;cio do pinhole, maior o fator de magnifica&#231;&#227;o do objeto a ser estudado. Tamb&#233;m &#233; importante ressaltar que a sensibilidade do sistema (velocidade de ac&#250;mulo de contagens) &#233; uma fun&#231;&#227;o da &#225;rea do orif&#237;cio do colimador. No nosso equipamento, &#233; poss&#237;vel a utiliza&#231;&#227;o de diferentes di&#226;metros de orif&#237;cio (de 0,5 a 2 mm), feitos de chumbo ou ouro, assim como colimadores com m&#250;ltiplos orif&#237;cios, o que pode otimizar o processo de aquisi&#231;&#227;o das imagens cintilogr&#225;ficas.</p>
    <p>V&#225;rios argumentos podem ser elencados para salientar a import&#226;ncia da obten&#231;&#227;o de imagens de perfus&#227;o mioc&#225;rdica de alta resolu&#231;&#227;o em modelos experimentais de cardiopatia isqu&#234;mica e de isquemia/reperfus&#227;o. A indu&#231;&#227;o de infarto mioc&#225;rdico &#233; o modelo de insufici&#234;ncia card&#237;aca/disfun&#231;&#227;o ventricular esquerda mais frequentemente empregado na pesquisa pr&#233;-cl&#237;nica<sup>22</sup>. A quantifica&#231;&#227;o precisa da extens&#227;o da fibrose por m&#233;todos de imagem <italic>in vivo</italic> podem representar aux&#237;lio relevante na caracteriza&#231;&#227;o desses modelos, permitindo a sele&#231;&#227;o de animais mais homog&#234;neos em rela&#231;&#227;o ao tamanho do infarto, bem como aquilatar, de forma longitudinal, o efeito de terapias anti-isqu&#234;micas e estrat&#233;gias de reperfus&#227;o mioc&#225;rdica, assemelhando-se ao que foi descrito nos estudos cl&#237;nicos empregando o SPECT de perfus&#227;o mioc&#225;rdica<sup>23</sup>. </p>
    <p>Por outro lado, a avalia&#231;&#227;o sequencial do tamanho da &#225;rea de infarto &#233; um aspecto cr&#237;tico nos estudos, envolvendo terapia celular de regenera&#231;&#227;o mioc&#225;rdica com c&#233;lulas tronco, da mesma forma como tem sido empregada em estudos cl&#237;nicos recentes<sup>24,25</sup>. </p>
    <p>&#201; relevante mencionar que a ecocardiografia tem sido amplamente utilizada na pesquisa pr&#233;-cl&#237;nica, n&#227;o apenas para estimar o tamanho do infarto mioc&#225;rdico, mas tamb&#233;m para fornecer medidas do grau de remodelamento ventricular esquerdo subsequente<sup>26</sup>. </p>
    <p>No entanto, vale ressaltar que o emprego dos m&#233;todos de imagem que avaliam a fun&#231;&#227;o sist&#243;lica ventricular esquerda para mensurar de forma indireta a extens&#227;o do infarto mioc&#225;rdico est&#225; sujeito a v&#225;rios fatores que podem levar &#224; imprecis&#227;o. A estimativa do tamanho do infarto mioc&#225;rdico a partir da extens&#227;o da &#225;rea de dissinergia contr&#225;til pode ser contaminada por fatores confusores, como a presen&#231;a de mioc&#225;rdio vi&#225;vel, mas transitoriamente disfuncionante (mioc&#225;rdio atordoado) e a mudan&#231;a do grau de atividade contr&#225;til vicariante das paredes distantes &#224; &#225;rea de infarto. Esses fatores podem mascarar os resultados de terapias voltadas para o salvamento do mioc&#225;rdio isqu&#234;mico ou aquelas agindo sobre o remodelamento card&#237;aco<sup>27</sup>. </p>
    <p>Portanto, o aspecto central envolvido na compara&#231;&#227;o entre os diferentes m&#233;todos para avalia&#231;&#227;o do tamanho do infarto &#233; que as imagens de SPECT de perfus&#227;o mioc&#225;rdica podem avaliar funcionalmente a extens&#227;o do mioc&#225;rdio vi&#225;vel e, consequentemente, o tamanho do mioc&#225;rdio necrosado. Essa avalia&#231;&#227;o direta funcional/metab&#243;lica independe do <italic>status</italic> de mobilidade das paredes, ou seja, mesmo &#225;reas atordoadas seriam julgadas como vi&#225;veis e as &#225;reas "encabrestadas" (&#225;reas de fibrose/necrose exibindo mobilidade por estarem ancoradas em segmentos circunvizinhos com contratilidade aumentada) seriam corretamente julgadas como necr&#243;ticas. Desse modo, reproduzindo o que a literatura internacional j&#225; demonstrou em estudos cl&#237;nicos, julgamos que a avalia&#231;&#227;o funcional/metab&#243;lica cintilogr&#225;fica acrescenta importantes informa&#231;&#245;es para diagn&#243;stico do mioc&#225;rdio vi&#225;vel e, por extens&#227;o, da necrose mioc&#225;rdica, al&#233;m do que a avalia&#231;&#227;o da mobilidade segmentar parietal pode fornecer. Acreditamos, assim, que imagens de SPECT de perfus&#227;o mioc&#225;rdica serviriam como uma ferramenta adicional aliada ao ecocardiograma (este sendo o m&#233;todo padr&#227;o para medir o grau de remodelamento e da disfun&#231;&#227;o sist&#243;lica) para avalia&#231;&#227;o mais completa dos modelos de cardiopatia isqu&#234;mica, assim como para medir o impacto de terapias celulares de regenera&#231;&#227;o mioc&#225;rdica.</p>
    <p>
      <bold>Conclus&#227;o</bold>
    </p>
    <p>O sistema desenvolvido apresentou alta resolu&#231;&#227;o espacial e elevada acur&#225;cia para detec&#231;&#227;o e quantifica&#231;&#227;o das &#225;reas de fibrose mioc&#225;rdica, sendo uma op&#231;&#227;o de baixo custo e grande versatilidade para obten&#231;&#227;o de imagens em SPECT de alta resolu&#231;&#227;o de &#243;rg&#227;os de pequenos animais.</p>
    <p>As facilidades tecnol&#243;gicas descritas e validadas no presente estudo t&#234;m o potencial de contribuir para popularizar o emprego da avalia&#231;&#227;o funcional com imagens cintilogr&#225;ficas na pesquisa pr&#233;-cl&#237;nica cardiol&#243;gica no cen&#225;rio cient&#237;fico brasileiro. </p>
    <p>
      <bold>Fontes de financiamento</bold>
    </p>
    <p>O presente foi estudo foi financiado pela Funda&#231;&#227;o de Amparo &#224; Pesquisa do Estado de S&#227;o Paulo (FAPESP), com processos 07/50339-3 e 2011/03261-4, pela Funda&#231;&#227;o de Apoio ao Ensino, Pesquisa e Assist&#234;ncia (FAEPA) do Hospital das Cl&#237;nicas da Faculdade de Medicina de Ribeir&#227;o Preto (HCFMRP) da Universidade de S&#227;o Paulo (USP) e Conselho Nacional de Desenvolvimento Cient&#237;fico e Tecnol&#243;gico (CNPq). JM recebeu bolsa do Programa de Apoio a Jovem Pesquisador em Centros Emergentes.</p>
    <p>
      <bold>Contribui&#231;&#227;o dos autores</bold>
    </p>
    <p>Concep&#231;&#227;o e desenho da pesquisa: Mejia J, Galvis-Alonso OY, Sim&#245;es MV; Obten&#231;&#227;o de dados: Oliveira LFL, Mejia J, Carvalho EEV, Lataro RM, Frassetto SN, Fazan Jr. R, Salgado HC; An&#225;lise e interpreta&#231;&#227;o dos dados: Oliveira LFL, Carvalho EEV, Lataro RM, Sim&#245;es MV; An&#225;lise estat&#237;stica: Oliveira LFL, Carvalho EEV; Obten&#231;&#227;o de financiamento: Mejia J; Reda&#231;&#227;o do manuscrito: Oliveira LFL; Revis&#227;o cr&#237;tica do manuscrito quanto ao conte&#250;do intelectual: Oliveira LFL, Mejia J, Galvis-Alonso OY, Sim&#245;es MV.</p>
    <p>
      <bold>Potencial Conflito de Interesses</bold>
    </p>
    <p>Declaro n&#227;o haver conflito de interesses pertinentes.</p>
    <p>
      <bold>Fontes de Financiamento</bold>
    </p>
    <p>O presente estudo foi parcialmente financiado pela FAPESP, FAEPA-HCFMRP e CNPq.</p>
    <p>
      <bold>Vincula&#231;&#227;o Acad&#234;mica</bold>
    </p>
    <p>Este artigo &#233; parte de disserta&#231;&#227;o de Mestrado de Luciano Fonseca Lemos de Oliveira pela Faculdade de Medicina de Ribeir&#227;o Preto - USP.</p>
    <p>
      <fn id="end" fn-type="corresp">
        <label>
          <bold>Correspond&#234;ncia:</bold>
        </label>
        <p> Marcus Vinicius Sim&#245;es </p>
        <p> Divis&#227;o de Cardiologia - Hospital das Cl&#237;nicas da Faculdade de Medicina de Ribeir&#227;o Preto da Universidade de S&#227;o Paulo </p>
        <p> Av. Bandeirantes 3900 </p>
        <p> CEP: 14048-900 - Ribeir&#227;o Preto - S&#227;o Paulo </p>
        <p> Email: </p>
        <p>
          <email xlink:href="msimoes@fmrp.usp.br">msimoes@fmrp.usp.br</email>
        </p>
      </fn>
    </p>
    <p> Artigo recebido em 1/9/12, revisado em 17/9/12, aceito em 6/3/13.</p>
  </body>
  <back>
    <ref-list>
      <ref id="B1">
        <mixed-citation>1. Institute of Laboratory Animal Resources (U.S.). Committee on Rodents. Rodents. Washington, DC: National Academy Press; 1996.</mixed-citation>
        <element-citation publication-type="book">
          <source>Rodents</source>
          <date>
            <year>1996</year>
          </date>
        </element-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Tucci PJ. Pathophysiological characteristics of the post-myocardial infarction heart failure model in rats. Arq Bras Cardiol. 2011;96(5):420-4.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Pathophysiological characteristics of the post-myocardial infarction heart failure model in rats</article-title>
          <source>Arq Bras Cardiol</source>
          <date>
            <year>2011</year>
          </date>
          <fpage>420</fpage>
          <lpage>4</lpage>
          <issue>5</issue>
          <volume>96</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Tucci</surname>
              <given-names>PJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. Zornoff LA, Paiva SA, Minicucci MF, Spadaro J. Experimental myocardium infarction in rats: analysis of the model. Arq Bras Cardiol. 2009;93(4):434-40, 426-32.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Experimental myocardium infarction in rats: analysis of the model</article-title>
          <source>Arq Bras Cardiol</source>
          <date>
            <year>2009</year>
          </date>
          <fpage>434</fpage>
          <lpage>40</lpage>
          <issue>4</issue>
          <volume>93</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Zornoff</surname>
              <given-names>LA</given-names>
            </name>
            <name>
              <surname>Paiva</surname>
              <given-names>SA</given-names>
            </name>
            <name>
              <surname>Minicucci</surname>
              <given-names>MF</given-names>
            </name>
            <name>
              <surname>Spadaro</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Dornas WC, Oliveira TT, Augusto LE, Nagem TJ. Experimental atherosclerosis in rabbits. Arq Bras Cardiol. 2010;95(2):272-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Experimental atherosclerosis in rabbits</article-title>
          <source>Arq Bras Cardiol</source>
          <date>
            <year>2010</year>
          </date>
          <fpage>272</fpage>
          <lpage>8</lpage>
          <issue>2</issue>
          <volume>95</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Dornas</surname>
              <given-names>WC</given-names>
            </name>
            <name>
              <surname>Oliveira</surname>
              <given-names>TT</given-names>
            </name>
            <name>
              <surname>Augusto</surname>
              <given-names>LE</given-names>
            </name>
            <name>
              <surname>Nagem</surname>
              <given-names>TJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. Klocke R, Tian W, Kuhlmann MT, Nikol S. Surgical animal models of heart failure related to coronary heart disease. Cardiovasc Res. 2007;74(1):29-38.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Surgical animal models of heart failure related to coronary heart disease</article-title>
          <source>Cardiovasc Res</source>
          <date>
            <year>2007</year>
          </date>
          <fpage>29</fpage>
          <lpage>38</lpage>
          <issue>1</issue>
          <volume>74</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Klocke</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Tian</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Kuhlmann</surname>
              <given-names>MT</given-names>
            </name>
            <name>
              <surname>Nikol</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B6">
        <mixed-citation>6. Mejia J, Galvis-Alonso OY, Braga J, Correa R, Leite JP, Sim&#245;es MV. Methodological approaches to planar and volumetric scintigraphic imaging of small volume targets with high spatial resolution and sensitivity. Braz J Med Biol Res. 2009;42(8):692-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Methodological approaches to planar and volumetric scintigraphic imaging of small volume targets with high spatial resolution and sensitivity</article-title>
          <source>Braz J Med Biol Res</source>
          <date>
            <year>2009</year>
          </date>
          <fpage>692</fpage>
          <lpage>9</lpage>
          <issue>8</issue>
          <volume>42</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Mejia</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Galvis-Alonso</surname>
              <given-names>OY</given-names>
            </name>
            <name>
              <surname>Braga</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Correa</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Leite</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>Sim&#245;es</surname>
              <given-names>MV</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B7">
        <mixed-citation>7. Mejia J, Galvis-Alonso OY, Castro AA, Braga J, Leite JP, Sim&#245;es MV. A clinical gamma camera-based pinhole collimated system for high resolution small animal SPECT imaging. Braz J Med Biol Res. 2010;43(12):1160-6.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>A clinical gamma camera-based pinhole collimated system for high resolution small animal SPECT imaging</article-title>
          <source>Braz J Med Biol Res</source>
          <date>
            <year>2010</year>
          </date>
          <fpage>1160</fpage>
          <lpage>6</lpage>
          <issue>12</issue>
          <volume>43</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Mejia</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Galvis-Alonso</surname>
              <given-names>OY</given-names>
            </name>
            <name>
              <surname>Castro</surname>
              <given-names>AA</given-names>
            </name>
            <name>
              <surname>Braga</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Leite</surname>
              <given-names>JP</given-names>
            </name>
            <name>
              <surname>Sim&#245;es</surname>
              <given-names>MV</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B8">
        <mixed-citation>8. Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging. 1982;1(2):113-22.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Maximum likelihood reconstruction for emission tomography</article-title>
          <source>IEEE Trans Med Imaging</source>
          <date>
            <year>1982</year>
          </date>
          <fpage>113</fpage>
          <lpage>22</lpage>
          <issue>2</issue>
          <volume>1</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Shepp</surname>
              <given-names>LA</given-names>
            </name>
            <name>
              <surname>Vardi</surname>
              <given-names>Y</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B9">
        <mixed-citation>9. Chatziioannou A, Qi J, Moore A, Annala A, Nguyen K, Leahy R, et al. Comparison of 3-D maximum a posteriori and filtered backprojection algorithms for high-resolution animal imaging with microPET. IEEE Trans Med Imaging. 2000;19(5):507-12.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Comparison of 3-D maximum a posteriori and filtered backprojection algorithms for high-resolution animal imaging with microPET</article-title>
          <source>IEEE Trans Med Imaging</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>507</fpage>
          <lpage>12</lpage>
          <issue>5</issue>
          <volume>19</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Chatziioannou</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Qi</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Moore</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Annala</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Nguyen</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Leahy</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B10">
        <mixed-citation>10. Frese T, Rouze NC, Bouman CA, Sauer K, Hutchins GD. Quantitative comparison of FBP, EM, and Bayesian reconstruction algorithms for the IndyPET scanner. IEEE Trans Med Imaging. 2003;22(2):258-76.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Quantitative comparison of FBP, EM, and Bayesian reconstruction algorithms for the IndyPET scanner</article-title>
          <source>IEEE Trans Med Imaging</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>258</fpage>
          <lpage>76</lpage>
          <issue>2</issue>
          <volume>22</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Frese</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Rouze</surname>
              <given-names>NC</given-names>
            </name>
            <name>
              <surname>Bouman</surname>
              <given-names>CA</given-names>
            </name>
            <name>
              <surname>Sauer</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Hutchins</surname>
              <given-names>GD</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B11">
        <mixed-citation>11. Loening AM, Gambhir SS. AMIDE: a free software tool for multimodality medical image analysis. Mol Imaging. 2003;2(3):131-7.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>AMIDE: a free software tool for multimodality medical image analysis</article-title>
          <source>Mol Imaging</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>131</fpage>
          <lpage>7</lpage>
          <issue>3</issue>
          <volume>2</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Loening</surname>
              <given-names>AM</given-names>
            </name>
            <name>
              <surname>Gambhir</surname>
              <given-names>SS</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B12">
        <mixed-citation>12. Pfeffer MA, Pfeffer JM, Fishbein MC, Fletcher PJ, Spadaro J, Kloner RA, et al. Myocardial infarct size and ventricular function in rats. Circ Res. 1979;44(4):503-12.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Myocardial infarct size and ventricular function in rats</article-title>
          <source>Circ Res</source>
          <date>
            <year>1979</year>
          </date>
          <fpage>503</fpage>
          <lpage>12</lpage>
          <issue>4</issue>
          <volume>44</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Pfeffer</surname>
              <given-names>MA</given-names>
            </name>
            <name>
              <surname>Pfeffer</surname>
              <given-names>JM</given-names>
            </name>
            <name>
              <surname>Fishbein</surname>
              <given-names>MC</given-names>
            </name>
            <name>
              <surname>Fletcher</surname>
              <given-names>PJ</given-names>
            </name>
            <name>
              <surname>Spadaro</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Kloner</surname>
              <given-names>RA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B13">
        <mixed-citation>13. Habraken JB, de Bruin K, Shehata M, Booij J, Bennink R, van Eck Smit BL, et al. Evaluation of high-resolution pinhole SPECT using a small rotating animal. J Nucl Med. 2001;42(12):1863-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Evaluation of high-resolution pinhole SPECT using a small rotating animal</article-title>
          <source>J Nucl Med</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>1863</fpage>
          <lpage>9</lpage>
          <issue>12</issue>
          <volume>42</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Habraken</surname>
              <given-names>JB</given-names>
            </name>
            <name>
              <surname>de Bruin</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Shehata</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Booij</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Bennink</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>van Eck Smit</surname>
              <given-names>BL</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B14">
        <mixed-citation>14. Wu MC, Gao DW, Sievers RE, Lee RJ, Hasegawa BH, Dae MW. Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice. J Am Coll Cardiol. 2003;42(3):576-82.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice</article-title>
          <source>J Am Coll Cardiol</source>
          <date>
            <year>2003</year>
          </date>
          <fpage>576</fpage>
          <lpage>82</lpage>
          <issue>3</issue>
          <volume>42</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Wu</surname>
              <given-names>MC</given-names>
            </name>
            <name>
              <surname>Gao</surname>
              <given-names>DW</given-names>
            </name>
            <name>
              <surname>Sievers</surname>
              <given-names>RE</given-names>
            </name>
            <name>
              <surname>Lee</surname>
              <given-names>RJ</given-names>
            </name>
            <name>
              <surname>Hasegawa</surname>
              <given-names>BH</given-names>
            </name>
            <name>
              <surname>Dae</surname>
              <given-names>MW</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B15">
        <mixed-citation>15. Moons CP, Peremans K, Vermeire S, Vandermeulen E, Dobbeleir A, Hermans K, et al. The Use of HiSPECT to Investigate Dopaminergic Involvement in the Development of Stereotypic Behaviour. Scand J Lab Anim Sci. 2008;35(4):221-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>The Use of HiSPECT to Investigate Dopaminergic Involvement in the Development of Stereotypic Behaviour</article-title>
          <source>Scand J Lab Anim Sci</source>
          <date>
            <year>2008</year>
          </date>
          <fpage>221</fpage>
          <lpage>9</lpage>
          <issue>4</issue>
          <volume>35</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Moons</surname>
              <given-names>CP</given-names>
            </name>
            <name>
              <surname>Peremans</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Vermeire</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Vandermeulen</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Dobbeleir</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Hermans</surname>
              <given-names>K</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B16">
        <mixed-citation>16. Liu ZL, Kastis GA, Stevenson GD, Barrett HH, Furenlid LR, Kupinski MA, et al. Quantitative analysis of acute myocardial infarct in rat hearts with ischemia-reperfusion using a high-resolution stationary SPECT system. J Nucl Med. 2002;43(7):933-9.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Quantitative analysis of acute myocardial infarct in rat hearts with ischemia-reperfusion using a high-resolution stationary SPECT system</article-title>
          <source>J Nucl Med</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>933</fpage>
          <lpage>9</lpage>
          <issue>7</issue>
          <volume>43</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Liu</surname>
              <given-names>ZL</given-names>
            </name>
            <name>
              <surname>Kastis</surname>
              <given-names>GA</given-names>
            </name>
            <name>
              <surname>Stevenson</surname>
              <given-names>GD</given-names>
            </name>
            <name>
              <surname>Barrett</surname>
              <given-names>HH</given-names>
            </name>
            <name>
              <surname>Furenlid</surname>
              <given-names>LR</given-names>
            </name>
            <name>
              <surname>Kupinski</surname>
              <given-names>MA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B17">
        <mixed-citation>17. MacDonald LR, Patt BE, Iwanczyk JS, Tsui BM, Wang YC, Frey EC, et al. Pinhole SPECT of mice using the LumaGEM gamma camera. IEEE Trans Nucl Sci. 2001;48(3):830-6.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Pinhole SPECT of mice using the LumaGEM gamma camera</article-title>
          <source>IEEE Trans Nucl Sci</source>
          <date>
            <year>2001</year>
          </date>
          <fpage>830</fpage>
          <lpage>6</lpage>
          <issue>3</issue>
          <volume>48</volume>
          <person-group person-group-type="author">
            <name>
              <surname>MacDonald</surname>
              <given-names>LR</given-names>
            </name>
            <name>
              <surname>Patt</surname>
              <given-names>BE</given-names>
            </name>
            <name>
              <surname>Iwanczyk</surname>
              <given-names>JS</given-names>
            </name>
            <name>
              <surname>Tsui</surname>
              <given-names>BM</given-names>
            </name>
            <name>
              <surname>Wang</surname>
              <given-names>YC</given-names>
            </name>
            <name>
              <surname>Frey</surname>
              <given-names>EC</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B18">
        <mixed-citation>18. Wollenweber T, Zach C, Rischpler C, Fischer R, Nowak S, Nekolla SG, et al. Myocardial perfusion imaging is feasible for infarct size quantification in mice using a clinical single-photon emission computed tomography system equipped with pinhole collimators. Mol Imaging Biol. 2010;12(4):427-34.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Myocardial perfusion imaging is feasible for infarct size quantification in mice using a clinical single-photon emission computed tomography system equipped with pinhole collimators</article-title>
          <source>Mol Imaging Biol</source>
          <date>
            <year>2010</year>
          </date>
          <fpage>427</fpage>
          <lpage>34</lpage>
          <issue>4</issue>
          <volume>12</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Wollenweber</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Zach</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Rischpler</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Fischer</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Nowak</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Nekolla</surname>
              <given-names>SG</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B19">
        <mixed-citation>19. Hirai T, Nohara R, Hosokawa R, Tanaka M, Inada H, Fujibayashi Y, et al. Evaluation of myocardial infarct size in rat heart by pinhole SPECT. J Nucl Cardiol. 2000;7(2):107-11.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Evaluation of myocardial infarct size in rat heart by pinhole SPECT</article-title>
          <source>J Nucl Cardiol</source>
          <date>
            <year>2000</year>
          </date>
          <fpage>107</fpage>
          <lpage>11</lpage>
          <issue>2</issue>
          <volume>7</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Hirai</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Nohara</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Hosokawa</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Tanaka</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Inada</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Fujibayashi</surname>
              <given-names>Y</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B20">
        <mixed-citation>20. Acton PD, Thomas D, Zhou R. Quantitative imaging of myocardial infarct in rats with high resolution pinhole SPECT. Int J Cardiovasc Imaging. 2006;22(3-4):429-34.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Quantitative imaging of myocardial infarct in rats with high resolution pinhole SPECT</article-title>
          <source>Int J Cardiovasc Imaging</source>
          <date>
            <year>2006</year>
          </date>
          <fpage>429</fpage>
          <lpage>34</lpage>
          <issue>3-4</issue>
          <volume>22</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Acton</surname>
              <given-names>PD</given-names>
            </name>
            <name>
              <surname>Thomas</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Zhou</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B21">
        <mixed-citation>21. Cherry SR, Sorenson JA, Phelps ME. Physics in nuclear medicine. 3<sup>rd</sup> ed. Philadelphia, PA: Saunders; 2003.</mixed-citation>
        <element-citation publication-type="book">
          <source>Physics in nuclear medicine</source>
          <date>
            <year>2003</year>
          </date>
          <person-group person-group-type="author">
            <name>
              <surname>Cherry</surname>
              <given-names>SR</given-names>
            </name>
            <name>
              <surname>Sorenson</surname>
              <given-names>JA</given-names>
            </name>
            <name>
              <surname>Phelps</surname>
              <given-names>ME</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B22">
        <mixed-citation>22. Monnet E, Chachques JC. Animal models of heart failure: what is new? Ann Thorac Surg. 2005;79(4):1445-53.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Animal models of heart failure: what is new?</article-title>
          <source>Ann Thorac Surg</source>
          <date>
            <year>2005</year>
          </date>
          <fpage>1445</fpage>
          <lpage>53</lpage>
          <issue>4</issue>
          <volume>79</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Monnet</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Chachques</surname>
              <given-names>JC</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B23">
        <mixed-citation>23. Gibbons RJ. Tc-99m SPECT sestamibi for the measurement of infarct size. J Cardiovasc Pharmacol Ther. 2011;16(3-4):321-31.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Tc-99m SPECT sestamibi for the measurement of infarct size</article-title>
          <source>J Cardiovasc Pharmacol Ther</source>
          <date>
            <year>2011</year>
          </date>
          <fpage>321</fpage>
          <lpage>31</lpage>
          <issue>3-4</issue>
          <volume>16</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Gibbons</surname>
              <given-names>RJ</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B24">
        <mixed-citation>24. Strauer BE, Brehm M, Zeus T, Kostering M, Hernandez A, Sorg RV, et al. Repair of infarcted myocardium by autologous intracoronary mononuclear bone marrow cell transplantation in humans. Circulation. 2002;106(15):1913-8.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Repair of infarcted myocardium by autologous intracoronary mononuclear bone marrow cell transplantation in humans</article-title>
          <source>Circulation</source>
          <date>
            <year>2002</year>
          </date>
          <fpage>1913</fpage>
          <lpage>8</lpage>
          <issue>15</issue>
          <volume>106</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Strauer</surname>
              <given-names>BE</given-names>
            </name>
            <name>
              <surname>Brehm</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Zeus</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Kostering</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Hernandez</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Sorg</surname>
              <given-names>RV</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B25">
        <mixed-citation>25. Perin EC, Willerson JT, Pepine CJ, Henry TD, Ellis SG, Zhao DX, et al. Effect of transendocardial delivery of autologous bone marrow mononuclear cells on functional capacity, left ventricular function, and perfusion in chronic heart failure: the FOCUS-CCTRN trial. JAMA. 2012;307(16):1717-26.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Effect of transendocardial delivery of autologous bone marrow mononuclear cells on functional capacity, left ventricular function, and perfusion in chronic heart failure: the FOCUS-CCTRN trial</article-title>
          <source>JAMA</source>
          <date>
            <year>2012</year>
          </date>
          <fpage>1717</fpage>
          <lpage>26</lpage>
          <issue>16</issue>
          <volume>307</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Perin</surname>
              <given-names>EC</given-names>
            </name>
            <name>
              <surname>Willerson</surname>
              <given-names>JT</given-names>
            </name>
            <name>
              <surname>Pepine</surname>
              <given-names>CJ</given-names>
            </name>
            <name>
              <surname>Henry</surname>
              <given-names>TD</given-names>
            </name>
            <name>
              <surname>Ellis</surname>
              <given-names>SG</given-names>
            </name>
            <name>
              <surname>Zhao</surname>
              <given-names>DX</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B26">
        <mixed-citation>26. Minicucci MF, Azevedo PS, Matsubara BB, Matsubara LS, Paiva SA, Zornoff LA. [Association between sphericity, ventricular function and size of the infarction in rats]. Arq Bras Cardiol. 2010;94(5):645-50.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Association between sphericity.ventricular function and size of the infarction in rats</article-title>
          <source>Arq Bras Cardiol</source>
          <date>
            <year>2010</year>
          </date>
          <fpage>645</fpage>
          <lpage>50</lpage>
          <issue>5</issue>
          <volume>94</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Minicucci</surname>
              <given-names>MF</given-names>
            </name>
            <name>
              <surname>Azevedo</surname>
              <given-names>PS</given-names>
            </name>
            <name>
              <surname>Matsubara</surname>
              <given-names>BB</given-names>
            </name>
            <name>
              <surname>Matsubara</surname>
              <given-names>LS</given-names>
            </name>
            <name>
              <surname>Paiva</surname>
              <given-names>SA</given-names>
            </name>
            <name>
              <surname>Zornoff</surname>
              <given-names>LA</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
      <ref id="B27">
        <mixed-citation>27. Botker HE, Kaltoft AK, Pedersen SF, Kim WY. Measuring myocardial salvage. Cardiovasc Res. 2012;94(2):266-75.</mixed-citation>
        <element-citation publication-type="journal">
          <article-title>Measuring myocardial salvage</article-title>
          <source>Cardiovasc Res</source>
          <date>
            <year>2012</year>
          </date>
          <fpage>266</fpage>
          <lpage>75</lpage>
          <issue>2</issue>
          <volume>94</volume>
          <person-group person-group-type="author">
            <name>
              <surname>Botker</surname>
              <given-names>HE</given-names>
            </name>
            <name>
              <surname>Kaltoft</surname>
              <given-names>AK</given-names>
            </name>
            <name>
              <surname>Pedersen</surname>
              <given-names>SF</given-names>
            </name>
            <name>
              <surname>Kim</surname>
              <given-names>WY</given-names>
            </name>
          </person-group>
        </element-citation>
      </ref>
    </ref-list>
  </back>
  <sub-article article-type="translation" id="TRen" xml:lang="en">
    <front-stub>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Articles</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Myocardial infarction area quantification using high-resolution SPECT images in rats</article-title>
      </title-group>
      <abstract xml:lang="en">
        <p>BACKGROUND: Imaging techniques enable in vivo sequential assessment of the morphology and function of animal organs in experimental models. We developed a device for high-resolution single photon emission computed tomography (SPECT) imaging based on an adapted pinhole collimator. OBJECTIVE: To determine the accuracy of this system for quantification of myocardial infarct area in rats. METHODS: Thirteen male Wistar rats (250 g) underwent experimental myocardial infarction by occlusion of the left coronary artery. After 4 weeks, SPECT images were acquired 1.5 hours after intravenous injection of 555 MBq o f 99mTc-Sestamibi. The tomographic reconstruction was performed by using specially developed software based on the Maximum Likelihood algorithm. The analysis of the data included the correlation between the area of perfusion defects detected by scintigraphy and extent of myocardial fibrosis assessed by histology. RESULTS: The images showed a high target organ/background ratio with adequate visualization of the left ventricular walls and cavity. All animals presenting infarction areas were correctly identified by the perfusion images. There was no difference of the infarct area as measured by SPECT (21.1 &#177; 21.2%) and by histology (21.7 &#177; 22.0%; p=0.45). There was a strong correlation between individual values of the area of infarction measured by these two methods. CONCLUSION: The developed system presented adequate spatial resolution and high accuracy for the detection and quantification of myocardial infarction areas, consisting in a low cost and versatile option for high-resolution SPECT imaging of small rodents.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>Myocardial Infarction</kwd>
        <kwd>Rats</kwd>
        <kwd>Tomography, Emission-Computed</kwd>
      </kwd-group>
    </front-stub>
    <body>
      <p>
        <bold>ORIGINAL ARTICLE</bold>
      </p>
      <fig id="enda-body2"/>
      <p>Myocardial infarction area quantification using high-resolution SPECT images in rats</p>
      <p>
        <bold>Luciano Fonseca Lemos de Oliveira<sup>I</sup>; Jorge Mejia<sup>II</sup>; Eduardo Elias Vieira de Carvalho<sup>I</sup>; Renata Maria Lataro<sup>I</sup>; Sarita Nasbine Frassetto<sup>I</sup>; Rubens Fazan Jr<sup>III</sup>; H&#233;lio Cesar Salgado<sup>III</sup>; Orfa Yineth Galvis-Alonso<sup>II</sup>; Marcus Vin&#237;cius Sim&#245;es<sup>I</sup></bold>
      </p>
      <p><sup>I</sup>Divis&#227;o de Cardiologia, Departamento de Cl&#237;nica M&#233;dica, Faculdade de Medicina de Ribeir&#227;o Preto, Universidade de S&#227;o Paulo, Ribeir&#227;o Preto, SP</p>
      <p><sup>II</sup>Departamento de Biologia Molecular, Faculdade de Medicina de S&#227;o Jos&#233; do Rio Preto, S&#227;o Jos&#233; do Rio Preto, SP</p>
      <p><sup>III</sup>Departamento de Fisiologia, Faculdade de Medicina de Ribeir&#227;o Preto, Universidade de S&#227;o Paulo, Ribeir&#227;o Preto, SP - Brasil </p>
      <p>Mailing Address</p>
      <p>
        <bold>ABSTRACT</bold>
      </p>
      <p><bold>BACKGROUND:</bold> Imaging techniques enable in vivo sequential assessment of the morphology and function of animal organs in experimental models. We developed a device for high-resolution single photon emission computed tomography (SPECT) imaging based on an adapted pinhole collimator.</p>
      <p><bold>OBJECTIVE:</bold> To determine the accuracy of this system for quantification of myocardial infarct area in rats.</p>
      <p><bold>METHODS:</bold> Thirteen male Wistar rats (250 g) underwent experimental myocardial infarction by occlusion of the left coronary artery. After 4 weeks, SPECT images were acquired 1.5 hours after intravenous injection of 555 MBq o<sup>f 99</sup>mTc-Sestamibi. The tomographic reconstruction was performed by using specially developed software based on the Maximum Likelihood algorithm. The analysis of the data included the correlation between the area of perfusion defects detected by scintigraphy and extent of myocardial fibrosis assessed by histology.</p>
      <p><bold>RESULTS:</bold> The images showed a high target organ/background ratio with adequate visualization of the left ventricular walls and cavity. All animals presenting infarction areas were correctly identified by the perfusion images. There was no difference of the infarct area as measured by SPECT (21.1 &#177; 21.2%) and by histology (21.7 &#177; 22.0%; p=0.45). There was a strong correlation between individual values of the area of infarction measured by these two methods.</p>
      <p><bold>CONCLUSION:</bold> The developed system presented adequate spatial resolution and high accuracy for the detection and quantification of myocardial infarction areas, consisting in a low cost and versatile option for high-resolution SPECT imaging of small rodents. </p>
      <p><bold>Keywords:</bold> Myocardial Infarction; Rats; Tomography, Emission-Computed.</p>
      <p>
        <bold>Introduction</bold>
      </p>
      <p>In the last decades, lab animals have become important tools in pre-clinical research<sup>1</sup>. In Cardiology, small animals have been successfully used for reproducing various cardiac disease models and their results have allowed the study of new drugs, as well as the study of cardiac disease physiopathological mechanisms<sup>2-5</sup>.</p>
      <p>On exploring of these animal models, although many experimental variables can be evaluated in vivo, in the majority of cases the animal must be sacrificed and the organ of interest excised and processed for obtaining results. This process eliminates the possibility of multiple evaluations along the time. On the other hand, the recent development of in vivo imaging techniques in small animals allowed the non-invasive sequential assessment of organ structure and function, saving time and animals and reducing cost. </p>
      <p>The equipments in clinical use, based in ultrasond and magnetic resonance imaging, show sufficient sensivity and spatial resolution for imaging small animals organs, whose linear dimensions are, in average, 10 to 30 times smaller than that of human organs. However, conventional clinical SPECT (single-photon emission computed tomography) equipment allows spatial resolution of approximately 6 mm. This is not appropriate for imaging small animals organs, for which the required spatial resolution is approximately 1 mm.</p>
      <p>Our research group has recently described the implementation of a high-definition SPECT imaging system based on a pinhole collimator (with only one hole), a rotational support system for the small animal and appropriate software tools adapted to a gamma chamber for clinical use<sup>6,7</sup>. The objective of the present study was to validate this system for quantification in vivo of the myocardial fibrosis area in an experimental model of myocardial infarct in rats that uses as gold standard the in vitro histopathologic infarct measurement.</p>
      <p>
        <bold>Methods</bold>
      </p>
      <p>Construction and adaptation of the tomographic images acquisition system </p>
      <p>A clinical gamma chamber (DST/Sopha Medical Vision, Twinsburg, Ohio, USA) was adapted by the construction of a shielding system that allowed the fixation of a 1.5 mm diameter simple orifice collimator, with a 150&#186; total opening angle. This shielding system was pyramid-shaped and covered with a 6 mm lead mantle which was adequate for photons in the range of 150 keV. Additionally, a cylindrical support was developed for positioning the animal. This support is coupled to a motorized system, which allowed rotating the target to different angular positions, according to the number of projections to be registered throughout the 360&#186; tomographic acquisition. Synchronized with the dynamic acquisition protocol of the gamma chamber, the projection sequence was registered and stored in DICOM format. The hardware set is illustrated on <xref ref-type="fig" rid="en_a10fig01-body2">Figure 1</xref>. </p>
      <p content-type="asset">
        <fig id="en_a10fig01-body2">
          <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf01-en.jpg"/></fig>
      </p>
      <p>
        <bold>Reconstruction software implementation</bold>
      </p>
      <p>After acquiring the projections, the registered images were exported in DICOM format to a personal computer and were then processed for obtaining a tridimensional model for the radioactive drug distribution within the target <sup>7</sup>.In order to do this, we have developed an iterative image reconstruction software, based on the Maximum Likelihood algorithm<sup>8</sup>. The mathematical details of the iterative reconstruction calculations were published previously<sup>7</sup>. Even though the iterative reconstruction is slower than the filtered backprojection classic algorithm, it produces better quality images, in terms of the signal-noise rate and spatial resolution, and allows better modeling of the physical process involved in image acquisition<sup>9,10</sup>. The tool was implemented in C language, using a freeware Dev-V++ compiler (Bloodshed Software). The freeware Amide Medical Image Data Examiner<sup>11</sup> was used for the final visualization of the reconstructions.</p>
      <p>
        <bold>Phantom Images</bold>
      </p>
      <p>In order to verify the systems tomographic spatial resolution, hot bar phantom images were acquired. This phantom consists in four sets of cylindrical spaces with different diameters (1, 2, 3 and 4 mm), filled with sodium pertechnetate and separated by a distance equal to two times their diameter (<xref ref-type="fig" rid="en_a10fig02a_b-body2">Figure 2A</xref>). The same parameters employed for image acquisition of the experimental animals were used in the acquisition of the phantom images.</p>
      <p content-type="asset">
        <fig id="en_a10fig02a_b-body2">
          <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf02-en.jpg"/></fig>
      </p>
      <p>
        <bold>Experimental animals</bold>
      </p>
      <p>After the approval of our institutions Ethical Committee in Animal Experimentation, the experiments were performed with 15 male Wistar rats weighing initially 250 g. The animals were provided by the central biotery of the same institution, kept in a climatized animal house, with free access to water and standard food, and submitted to a 12 hour light/shadow rhythm with controlled temperature. In all the procedures, maximum effort was done to avoid unnecessary suffering of the animals.</p>
      <p>
        <bold>Experimental myocardial infarction induction</bold>
      </p>
      <p>Experimental myocardial infarct was induced in 13 animals using the method described by Pfeffer et al<sup>12</sup>, with slight modifications. Two animals were maintained as non-infarct controls. The surgical procedures were performed under anesthesia with ketamine (50 mg/kg IM, Uni&#227;o Qu&#237;mica Farmac&#234;utica Nacional S/A, Embu-Gua&#231;u, SP, Brasil) and xylazine (10 mg/kg IM, HertapeCalier Sa&#250;de Animal S/A, Juatuba, MG, Brasil) and orotracheal intubation for mechanical ventilation (Advanced Safety Ventilator, Harvard Apparatus, MA1 55-7059, Holliston, MA, USA). After that, the heart was exposed by an incision in the third left intercostal space and the anterior descendent branch of the left coronary artery was identified and ligated with a polyester thread (4-0, Ethicon, S&#227;o Jos&#233; dos Campos, SP, Brasil). After that, the thorax was closed and the animals taken to our institutions Physiology Department Biotery for recovery.</p>
      <p>
        <bold>Myocardial perfusion images acquisition</bold>
      </p>
      <p>The animals were submitted to imaging 4 weeks after the experimental myocardial infarct induction. For the imaging protocol, the animals were anesthetized with a combination of ketamine and xylazine (50 e 5 mg/kg, respectively). A 555 MBq de 99mTc-Sestamibi activity was injected in the tail vein. Ninety minutes after the injections, the animals were anesthetized again with ketamine and xylazine (75 and 7.5 mg/kg, respectively) and positioned in the imaging system.</p>
      <p>Thirty-six projections, equally spaced within 360&#186;, were obtained in all imaging protocols. The projections were recorded in a 128 x128 matrix, each element with a 3.4 mm x 3.4 mm area. A 6.3X magnification factor was adopted for all experiments, corresponding to a lateral dimension of the volumetric picture element (or voxel) of 0.54 mm. The imaging time was 30 seconds for each projection, totaling approximately 21 minutes per animal.</p>
      <p>No deaths were recorded in association to imaging within 4 weeks of the infarction.</p>
      <p>
        <bold>Myocardial perfusion images processing and analysis</bold>
      </p>
      <p>After reconstructing SPECT images with an iteractive reconstruction algorithm, the image was properly rotated and tomographic slices were selected from the short, long vertical and long horizontal axis. The images were normalized for the myocardial pixel with the maximum uptake value within the volume and submitted to visual analysis. </p>
      <p>Four short axis tomographic slices from different levels within the left ventricular chamber were used for quantifying the perfusional defect in SPECT images: one apical slice, two medium-ventricular slices and one basal slice. Using ImageJ (a free image processing software), the intensity profile was determined at the left ventricle (LV) myocardial circumference. The areas with perfusion defects were identified by the presence of pixels with uptake values below 50% in comparison to the pixel showing the maximum caption accumulation in the myocardium. The total extension of the myocardial perfusion defect was expressed as a LV area percentage, and calculated by dividing the total pixel number with uptake &lt; 50% (from the four slices) by the total pixel number of the LV circumferential profile in the four tomographic slices that were analyzed, multiplied by one hundred. </p>
      <p>A single investigator, blind to the histologic analysis results, was responsible for the quantitative image processing.</p>
      <p>
        <bold>Histology</bold>
      </p>
      <p>For histopathologic analysis after euthanasia, the heart was rapidly excised and fixed in 10% formaldehyde for 24 hours, and, afterwards, transferred to 70% alcohol. The samples were progressively dehydrated and embedded in paraffin. Histologic slices were produced following the plane perpendicular to the hearts long axis, in order to reproduce the short axis slices obtained in the in vivo myocardial perfusion studies. The slices were stained with Massons trichrome stain for the perfect identification of fibrosis areas, which are stained in blue.</p>
      <p>For fibrosis area quantification in the histologic studies, the tomographic slices were processed similarly to the ones used in the in vivo perfusion studies. In summary, the images corresponding to the four slice levels in the left ventricular chamber were digitalized with the help of a scanner. A circumferential profile following LV wall conformation was delineated by the ImageJ software, and the linear extension of LV circumference was computed for each slice. The fibrosis-stained myocardial tissue linear extension was also identified and quantified in each slice. The myocardial fibrosis extension, expressed as a percentage of the LV surface area, was calculated by dividing the fibrotic tissue total extension in the four slices by the total LV circumferences extension in the four slices and multiplying the final value by 100. </p>
      <p>A single investigator, blind to the results obtained in the in vivo images, quantified the fibrosis areas in histologic studies.</p>
      <p>
        <bold>Statistical analysis</bold>
      </p>
      <p>The results were expressed as mean and mean standard deviation. The variable Gaussian distribution was verified by the Kolmogorov-Smirnov test. The paired t Student test was used for comparing the mean in vivo and histologic myocardial fibrosis extension values. The linear regression test and least square method were used for analyzing the correlation between the individual results obtained with each method. The Bland-Altman graphic method was used for additional concordance analysis between the fibrosis area measurements obtained by the two employed methods. </p>
      <p>
        <bold>Results</bold>
      </p>
      <p>
        <bold>Spatial resolution of tomographic images</bold>
      </p>
      <p><xref ref-type="fig" rid="en_a10fig02a_b-body2">Figure 2B</xref> shows the tomographic images of the micro-Jasczak phantom radioactivity filled bars reconstructed from the transversal slices, in a section perpendicular to the long axis. In a visual semi quantitative analysis, it is possible to clearly identify the contours of the group bars with internal diameters of 2 mm, though the image resolution is lost at 1 mm internal diameter, which suggests that the spatial resolution limit is within the 1-2 mm range. More precise spatial resolution determination was possible by analyzing the count profile from a linear source (PSF), which led to a 1.5 mm spatial resolution (full width at half maximum). The pixel size in the imaged object was 0.6 mm.</p>
      <p>
        <bold>Visual analysis of the myocardial perfusion images</bold>
      </p>
      <p><xref ref-type="fig" rid="en_a10fig03-body2">Figure 3</xref> shows images of the myocardial perfusion SPECT of one of the control animals, used for the initial imaging visualization standardization. High target-organ/background count ratio was observed; the wall limits and LV chamber delineation, as well as RV walls in some of the medium-chamber slices, were clearly visualized. The control animals images show uniform distribution of the radiotracer among different myocardial follow-ups, with the exception of the apex, which showed smaller uptake intensity, ascribed to the parietal thinning of the apical region. However, these values were not inferior to 50% in comparison to the maximum myocardial uptake accumulation pixel.</p>
      <p content-type="asset">
        <fig id="en_a10fig03-body2">
          <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf03-en.jpg"/></fig>
      </p>
      <p>The image quality of the infarcted animals (<xref ref-type="fig" rid="en_a10fig04-body2">Figure 4</xref>) and the control animals is comparable; besides, the uptake defect was clearly identified in territories compatible with the left coronary artery irrigation area in the rat (anterior and anterolateral walls and apical region) in all animals, with significant infarct areas confirmed by histology. </p>
      <p content-type="asset">
        <fig id="en_a10fig04-body2">
          <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf04-en.jpg"/></fig>
      </p>
      <p>
        <bold>Quantitative analysis of the myocardial infarction areas</bold>
      </p>
      <p>In <xref ref-type="fig" rid="en_a10fig05-body2">Figure 5</xref>, we can compare SPECT myocardial perfusion tomographic images of the slices with the corresponding histologic images that were used for quantifying, respectively, the perfusional defect and the fibrosis area. Great similarity of the wall morphology, as well as the myocardial perfusional defect extension and topography, can be seen between SPECT images and histologic studies.</p>
      <p content-type="asset">
        <fig id="en_a10fig05-body2">
          <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf05-en.jpg"/></fig>
      </p>
      <p>The myocardial infarction area quantified by histology was 21.7 &#177; 22.0% of the LV surface. The myocardial infarct area dimensions showed great variation among animals, ranging from 26.5 to 55.0%. Six animals did not show significant fibrosis areas in the histopathologic study. </p>
      <p>All the animals with significant myocardial fibrosis in the histopathologic study were correctly identified by the presence of uptake defects in myocardial perfusion defects. The LV surface area in which an uptake defect detected at the myocardial perfusion SPECT (infarct area) was 21.1 &#177; 21.2% (ranging from 30.0 to 50.0%); the results were similar to the obtained in the histologic study (p=0.45).</p>
      <p>Excellent correlation was obtained between individual SPECT myocardial uptake defect values and histologic myocardial fibrosis extension by using linear regression analysis (n = 13. r = 0.99; p &lt; 0.0001). In the dispersion graphic, a slope=1.03, almost superimposed to the identity line between the results, can be seen (<xref ref-type="fig" rid="en_a10fig06-body2">Figure 6</xref>).</p>
      <p content-type="asset">
        <fig id="en_a10fig06-body2">
          <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf06-en.jpg"/></fig>
      </p>
      <p>High concordance between the results of both methods is showed by plotting the data according to the graphic method for Bland-Altman measurement concordance analysis (<xref ref-type="fig" rid="en_a10fig07-body2">Figure 7</xref>). As the graphic shows, the mean difference between measurements was -0.6, a value close to zero (the ideal value). The individual values of the measurement differences are distributed in a narrow range around the mean, within the representative bars of two standard deviations, demonstrating that the variation limit for the difference between measurements was fairly acceptable (&#177;5,4%).</p>
      <p content-type="asset">
        <fig id="en_a10fig07-body2">
          <graphic xlink:href="1678-4170-abc-101-01-0059-30110-gf07-en.jpg"/></fig>
      </p>
      <p>
        <bold>Discussion</bold>
      </p>
      <p>In this study, we describe a system for obtaining high resolution SPECT images in small animals based on a pinhole collimator coupled to a rotational support and adapted to a clinical gamma-chamber. To the best of our knowledge, this is the first time an equivalent device is developed in Latin America. This systems performance allowed identifying 1-2 mm structures with 1.5 mm spatial resolution (FWHM) and a 0.6 mm pixel size. These values are similar to the ones reported in other studies describing systems adapted in clinical gamma-camera <sup>13-15</sup> and systems especially built for small animals<sup>16-18</sup>.</p>
      <p>In addition to their high spatial resolution, the myocardial perfusion SPECT images obtained both from infarct and control animals achieved quality comparable to human images, with adequate visualization of the left ventricle walls and chamber, as well as right ventricle wall visualization in some slices, with a high target-organ/background count ratio. </p>
      <p>The wall morphology and infarct area topography, according to myocardial perfusion SPECT images of the animals submitted to experimental infarct, were very similar to the ones obtained in the histopathologic study. Additionally, the myocardial perfusion defect extension showed high correlation with the infarct area histologic measurement. Regarding accuracy in the quantification of the infarct area extension, our results are comparable to the ones reported in other studies in with rats and mice were used with other high resolution scintigraphic imaging systems<sup>13,14,18-20</sup>. The findings suggest that, as a whole, the systems performance and accuracy is comparable to the commercially available dedicated systems.</p>
      <p>An open architecture imaging system, such as the one described here, is very versatile, since, besides being easily coupled to other gamma-camera, it allows, with small configuration changes, imaging different sized animals ranging from 30 to 800 g. These changes consist in changing the rotational support to others with different widths and adjusting the distance between the animal to be studied and the pinhole, leading to different magnification of the imaged object. This versatility allows also adjusting for the optimization of the imaging parameters of different modalities of cardiac scintigraphic studies in the same animal (e.g., tomographic and planar nuclear ventriculography and perfusion gated-SPECT) and for obtaining functional imaging of different organs (e.g., brain, kidney, thyroid and lungs). Besides, when compared to the commercially available SPECT imaging systems dedicated to small animals, the construction costs of the system described here are incomparably smaller. Approximately $ 5,000 was invested in the materials and the skilled labor employed in its physical assemblage. The reconstruction software development employed freeware platforms and the mathematical formulas and algorithms of the software had been previously published<sup>7</sup>.</p>
      <p>Other additional technical aspect must be presented in order to explain the advantages of configuring this kind of imaging system, in which the target (the small animal) is rotated in front of the detector. SPECT images are based on the acquisition of a planar images (projections) set in different angles around an object. In a clinical scenario, the projections are usually obtained by parallel collimators, so that the detector head rotates circumferentially around the patient, yielding images with a spatial resolution of approximately 6 mm (width at half the height)<sup>21</sup>. In order to image small animals organs, it is technically more advantageous to rotate the animal, and not the detector, for obtaining the projections. This way, most misalignments and oscillations caused by the gamma-camera detector head movement are eliminated, and the construction costs and the systems operation space are minimized.</p>
      <p>Differently from what happens when parallel hole collimators are used, there is an implicit magnification factor of the pinhole collimator. This magnification is related to the ratio between the distances of the detector and collimator and the target object and the collimator. The closer the pinhole, the greater the magnification factor of the object being studied. It is also important to highlight that the systems sensitivity (the count accumulation rate) is a function of the collimator hole area. With our equipment, it is possible to used different lead or gold hole diameters (ranging from 0.5 to 2.0 mm), as well as multiple hole collimators, which can optimize the scintigraphic imaging process.</p>
      <p>Various points can be selected to highlight the importance of high resolution perfusion imaging in ischemia/reperfusion and ischemic cardiopathy experimental models. Myocardial infarct induction is the heart failure/left ventricular dysfunction model most frequently used in pre-clinical research<sup>22</sup>. The precise quantification of fibrosis extension using imaging methods in vivo may be relevant for characterizing such models, allowing the selection of more homogeneous animals regarding infarct size, as well the longitudinal assessment of the effect of anti-ischemic therapies and myocardial reperfusion strategies, similarly to the described in myocardial perfusion SPECT clinical studies<sup>23.</sup></p>
      <p>On the other side, the sequential evaluation of the infarct area dimensions is a critical aspect of the studies on stem cell therapies for myocardial regeneration, much in the same way it has been employed in recent clinical studies<sup>24,25. </sup>.</p>
      <p>It is relevant to mention that echocardiography has been broadly used in pre-clinical research, not only for estimating myocardial infarct dimensions, but also for measuring the subsequent left ventricle remodelation degree<sup>26</sup>.</p>
      <p>However, it must be highlighted that the utilization of imaging methods that evaluate left ventricular systolic function for measuring indirectly the myocardial infarct extension is subject to various factors that can lead to inaccuracy. The estimation of the myocardial infarct dimensions by the contractile dissinergy area extension can be contaminated by confounding factors, such as the presence of viable, but transiently dysfunctional, myocardium (stunned myocardium) and the change in the vicarious contractile activity degree of the walls distant from the infarct area. These factors can mask the results of therapies aimed at ischemic myocardial salvage or those acting on cardiac remodeling<sup>27</sup>.</p>
      <p>Thus, the central aspect involved in the comparison of different methods for evaluating infarct size is that myocardial perfusion SPECT can evaluate functionally the extension of viable myocardium and, consequently, the extension of necrotic myocardium. This direct functional/metabolic evaluation does not depend on the wall mobility status, that is, even stunned areas would be judged viable and "tethered" myocardium (fibrosis/necrosis areas exhibiting mobility since they are anchored in circumjacent segments with enhanced contractility) would be correctly judged necrotic. So, reproducing what the international literature has demonstrated in clinical studies, according to our judgment, the scintigraphic functional/metabolic assessment adds important information to the diagnosis of viable myocardium and, by extension, myocardial necrosis, in addition to the information provided by segmental mobility. We believe, thus, that myocardial perfusion SPECT would be an additional tool to echocardiogram (which is still the standard method for measuring the systolic dysfunction and remodeling degree) for more complete evaluation of the ischemic cardiopathy models, as well as measuring the impact of myocardial regeneration cell therapies.</p>
      <p>
        <bold>Conclusion</bold>
      </p>
      <p>The system developed by us showed high spatial resolution and accuracy in the detection and quantification of myocardial fibrosis areas. It is a low cost tool with great versatility for high resolution SPECT imaging of small animals organs.</p>
      <p>The technological improvements described and validated in the present study may potentially contribute to the popularization of scintigraphic functional assessment in the pre-clinical cardiologic research in the Brazilian scientific setting.</p>
      <p>
        <bold>Funding</bold>
      </p>
      <p>The preset study was funded by the S&#227;o Paulo research Foundation (FAPESP), processes 07/50339-3 and 2011/03261-4, by the Teaching and Assistance Foundation (FAEPA) of the Clinical Hospital of the Medical School of Ribeir&#227;o Preto (HCFMRP), S&#227;o Paulo University (USP) and National Council for Scientific and Technological Development (CNPq). JM was granted a scholarship of the Emergent Centers Young Researcher Support System.</p>
      <p>
        <bold>Author contributions</bold>
      </p>
      <p>Conception and design of the research: Mejia J, Galvis-Alonso OY, Sim&#245;es MV; Acquisition of data: Oliveira LFL, Mejia J, Carvalho EEV, Lataro RM, Frassetto SN, Fazan Jr. R, Salgado HC; Analysis and interpretation of the data: Oliveira LFL, Carvalho EEV, Lataro RM, Sim&#245;es MV; Statistical analysis: Oliveira LFL, Carvalho EEV; Obtaining funding: Mejia J; Writing of the manuscript: Oliveira LFL; Critical revision of the manuscript for intellectual content: Oliveira LFL, Mejia J, Galvis-Alonso OY, Sim&#245;es MV.</p>
      <p>
        <bold>Potential Conflict of Interest</bold>
      </p>
      <p>No potential conflict of interest relevant to this article was reported.</p>
      <p>
        <bold>Sources of Funding</bold>
      </p>
      <p>This study was partially funded by FAPESP, FAEPA-HCFMRP and CNPq.</p>
      <p>
        <bold>Study Association</bold>
      </p>
      <p>This article is part of the thesis of master submitted by Luciano Fonseca Lemos de Oliveira, from Faculdade de Medicina de Ribeir&#227;o Preto - USP.</p>
      <p>
        <bold>References</bold>
      </p>
    </body>
  </sub-article>
</article>
